• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 321
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 327
  • 199
  • 61
  • 42
  • 41
  • 40
  • 39
  • 34
  • 30
  • 29
  • 28
  • 28
  • 26
  • 26
  • 25
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
241

Segurança microbiológica na abertura de ampolas com ênfase no procedimento de desinfecção / Microbiological safety in opening ampoules with an emphasis on disinfection procedure.

Rigotti, Marcelo Alessandro 24 August 2012 (has links)
O cuidado a saúde incorpora continuamente, novas tecnologias relacionadas a produtos e processos que podem trazer riscos, especialmente, quando não possuem embasamento técnico-científico. Ampolas de plástico são amplamente utilizadas no preparo de injetáveis, no entanto, a contaminação biológica das soluções na sua abertura é ainda questionável. Sabe-se que o risco de infecção tem etiologia multifacetada envolvendo aspectos complexos da microbiota endógena e das condições ambientais. O objetivo do estudo é contribuir para com a segurança microbiológica da abertura de ampolas com base no procedimento de desinfecção e, assim, minimizar os riscos de contaminação biológica no preparo de injetáveis. Trata-se de um experimento de laboratório que permitiu avaliar a esterilidade do conteúdo das ampolas e, consequentemente produziu evidencias acerca da segurança microbiológica no preparo de injetáveis. Para determinação se a abertura de ampolas possibilita veiculação bacteriana para as soluções utilizaram-se dois métodos de desinfecção do gargalo um com suabe e outro com algodão ambos umedecidos em álcool a 70%. Das 120 ampolas de plástico com água esterilizada 60 tiveram seus gargalos contaminados intencionalmente com Serratia marcescens (ATTCC 14756) e outra metade com Staphylococcus aureus resistente à meticilina (MRSA) (ATTCC 43300) na ordem de 106 UFC/mL. Na abertura das respectivas ampolas utilizaram-se os princípios e o rigor de assepsia em termos de higiene das mãos e uso de luvas esterilizadas. Na avaliação da positividade das culturas uma alíquota da solução de cada ampola foi pipetada em caldo nutriente e incubada a 35ºC por 14 dias. A fricção dos gargalos das ampolas com suabe ou bolas de algodão embebidas em 3 ml de álcool a 70% não foi eficaz na redução da contaminação do conteúdo destas ampolas. Evidencia-se que houve maior contaminação nas ampolas, intencionalmente contamindas com Serratia marcescens, que receberam desinfecção com suabe 19 (63,3%) comparado as ampolas 15 (50%) que foram desinfetadas com bolas de algodão embebidas em álcool. As ampolas contaminadas com Staphylococcus aureus resistente à meticilina independentemente de utilizar suabe ou bolas de algodão embebidas em álcool, a contaminação do conteúdo das ampolas foi alta 24 (80%) e 18 (60%), respectivamente. Das 60 (100%) ampolas contaminadas com Serratia marcescens 34 (56,7%) apresentaram contaminação da água destilada e, das 60 (100%) ampolas contaminadas com Staphylococcus aureus resistente à meticilina, 42 (70%) apresentaram contaminação. A elucidação do processo de contaminação do conteúdo de ampolas de plástico durante sua abertura é urgente, especialmente considerando a possibilidade do contato da solução com o meio externo e vice- versa. Consta-se que a temática carece de mais investimentos de pesquisa dado a relevância do procedimento de desinfecção na redução da carga microbiana. / The health care incorporates continuously new technologies related to products and administration processes that may pose risks, especially when there is no technical- scientific basis. Plastic ampoules are widely used in the preparation of injectables, however, biological contamination in solutions at its opening is still questionable. It is known that the risk of infection presents a multifaceted etiology involving complex aspects of endogenous microbiota and environmental conditions. The present investigation was carried out in order to contribute to the microbiological safety of opening ampoules based on disinfection procedure and thereby minimize the risk of biological contamination in the preparation of injectables. This is a laboratory experiment that allowed to evaluate the sterility of ampoules´ contents and consequently produced evidences regarding the microbiological safety in the preparation of injectables. To determine whether the opening of ampoules allows the carrying of bacteria into the solutions it was used two methods of ampoule neck disinfection, one with cotton balls and another with cotton swab both soaked with 70% alcohol. Of the 120 plastic ampoules containing sterile water, 60 had the ampoules necks intentionally contaminated with Serratia marcescens (ATTCC 14756) and the other half with methicillin-resistant Staphylococcus aureus (MRSA) (ATTCC 43300) of the order of 106 CFU/mL. At the opening of respective ampoules it was used the principles of strict asepsis and rigor in terms of hand hygiene and use of sterile gloves. In the evaluation of positive cultures an aliquot of solution from each ampoule was pipetted in nutrient broth and incubated at 35 °C for 14 days. Rub the ampoules necks with swab or cotton balls soaked with 70% alcohol in 3 ml was not effective in decreasing contamination of contents of those ampoules. It is evident that there were more contamination in ampoules intentionally contaminated with Serratia marcescens which received disinfection with swabs 19 (63.3%) if compared ampoules disinfected with cotton balls soaked in alcohol 15 (50%). Ampoules contaminated with methicillin-resistant Staphylococcus aureus neither swab nor cotton balls soaked in alcohol was effective, contamination of the contents of the ampoules 24 was high (80%) and 18 (60%), respectively. Of the 60 (100%) ampoules contaminated with Serratia marcescens 34 (56.7%) had distilled water contaminated, and from 60 (100%) ampoules contaminated with methicillin-resistant Staphylococcus aureus, 42 (70%) were contaminated. The elucidation of contamination process of contents of plastic ampoules during its opening is an urgent need, especially considering the possibility of contact of the solution with the external environment and vice versa. The evidence suggests that the issue needs more research investments given the relevance of the disinfection procedure in decreasing microbial load.
242

Avaliação microbiológica de circuitos respiratórios e anestésicos submetidos ao processo de desinfecção térmica

Oliveira, Andréa Ranucci 12 April 2012 (has links)
Made available in DSpace on 2016-01-26T12:51:48Z (GMT). No. of bitstreams: 1 andrearanuccideoliveira_dissert.pdf: 891643 bytes, checksum: 8f4fb2c47edb543f3ffbf41be6a1179a (MD5) Previous issue date: 2012-04-12 / Introduction: The reprocessing and reuse of medical practices are common in health care institutions in Brazil and several countries. However, it is necessary to establish parameters to guide the development, validation and implementation of reprocessing protocols, in order to ensure product quality and safety and health of patients. This conduct is an important infection control action, because microorganisms can remain in reprocessed medical supplies and cause a wide variety of infectious processes. Objective: To evaluate the efficiency of thermal disinfection procedure adopted for the reprocessing of breathing circuit used in anesthesia and mechanical ventilation in two hospitals in São José do Rio Preto, SP. Method: We performed microbiological tests for the detection, identification, assessment of antimicrobial susceptibility of microorganisms from the respiratory and anesthetic circuits termodesinfetados in two hospitals. Results: The Hospital identified in two samples coagulase-negative Staphylococcus and Pseudomonas aeruginosa, samples of Enterococcus spp termodesinfectadora identified, water samples were found P. aeruginosa and Citrobacter freundii, yeasts and Gram-negative bacilli. In hospital B samples showed contamination with Gram positive samples subjected to drying and termosesinfecção were contaminated by Acinetobacter calcoaceticus. Samples collected from the inner surfaces of the dryer were isolated A. calcoaceticus, A. baumannii, and Achromobacter xylosoxidans. Conclusion: We note that the thermal disinfection process was not efficient for the elimination of pathogens in peer-reviewed articles and drying equipment can act as contaminants after the disinfection process. / Introdução: O reprocessamento e reuso de artigos odonto médicos hospitalares são práticas comuns em instituições de assistência à saúde do Brasil e de diversos outros países. Entretanto, é necessário o estabelecimento de parâmetros que orientem a elaboração, validação e implantação de protocolos de reprocessamento, visando garantir a qualidade dos produtos e a segurança e saúde dos pacientes. Esta conduta é uma importante ação de controle de infecções, pois microrganismos podem permanecer em artigos médicos reprocessados e causar grande diversidade de processos infecciosos. Objetivo: Avaliar a eficiência do procedimento de termodesinfecção adotado para o reprocessamento dos circuitos respiratórios utilizados em ventilação mecânica e anestesia em dois hospitais do município de São José do Rio Preto, SP. Método: Foram realizadas análises microbiológicas para a detecção, identificação e avaliação da sensibilidade aos antimicrobianos, de microrganismos a partir dos circuitos anestésicos e respiratórios termodesinfetados nos dois hospitais. Resultados: No Hospital A foram identificados em duas amostras dos circuitos respiratórios Staphylococcus coagulase negativo e Pseudomonas aeruginosa, nas amostras da termodesinfectadora identificado Enterococcus spp, nas amostras da água foram encontrados P. aeruginosa e Citrobacter freundii, leveduras e bacilos Gram-negativos. No hospital B as amostras dos circuitos anestésicos apresentaram contaminação por bacilos Gram positivos, nas amostras submetidas a termosesinfecção e secagem recuperarou-ser Acinetobacter calcoaceticus. Nas amostras coletadas das superfícies internas da secadora foram isoladas A. calcoaceticus, A. baumannii e Achromobacter xylosoxidans. Conclusão: Observamos que o processo de termodesinfecção não foi eficiente para a eliminação de patógenos nos artigos avaliados e equipamentos de secagem podem atuar como contaminantes após o processo de desinfecção.
243

Limpeza e desinfecção de superfícies hospitalares: subsídio para elaboração e avaliação de rotinas.

Rigotti, Marcelo Alessandro 27 January 2017 (has links)
Submitted by Fabíola Silva (fabiola.silva@famerp.br) on 2018-01-09T11:43:21Z No. of bitstreams: 1 marceloalessandrorigotti_tese.pdf: 1594173 bytes, checksum: ab2cf8bf6df41438b2a1e87f2d06b4ff (MD5) / Made available in DSpace on 2018-01-09T11:43:21Z (GMT). No. of bitstreams: 1 marceloalessandrorigotti_tese.pdf: 1594173 bytes, checksum: ab2cf8bf6df41438b2a1e87f2d06b4ff (MD5) Previous issue date: 2017-01-27 / Introduction: Contamination of hospital surfaces plays an important role in the spread of infection related to health care. There is still no consensus as to how environmental surfaces should be cleaned and / or disinfected, and the most appropriate methods for assessing the cleaning / disinfection process. There are different systems for monitoring the efficiency of the process of cleaning hospital surfaces: among them, visual inspection, fluorescent marker, adenosine triphosphate by bioluminescence and microbiological cultures. Objectives: 1. To compare the efficiency of three surface friction techniques to reduce organic matter; 2. Evaluate the efficiency of concurrent cleaning / disinfection of operating room surfaces; 3. Evaluate the efficiency before / after cleaning / disinfection of operating room surfaces after review and implementation of an L / D protocol with an emphasis on educational and procedural interventions. Material and Methods: 1. Quantitative, descriptive and exploratory study carried out before and after the cleaning / disinfection process of the bedside tables of the patient unit. Three unidirectional, bi-directional and centrifugal friction techniques were performed individually on each table. For each patient unit and friction technique, a single table and cloth moistened with 70% alcohol (w / v) was used. Organic matter was detected by the presence of adenosine triphosphate by bioluminescence using the 3M ™ Clean-Trace ™ ATP Systems system. 2. A prospective, correlational study developed in the interior of São Paulo, in July 2014. Non - probabilistic sample consisted of the surfaces: surgical table, anesthesia machine, accessory table and counter, being evaluated by visual inspection, microbiological culture and adenosine triphosphate by bioluminescence, at the frequency of one operating room per day. 3. Similar to study 2, but between the months of July and August of 2014. Together, the coordinating nurse of the surgical unit carried out educational intervention and standardization of procedures. Results: 1. For each technique, 13 samples were collected before / after the cleaning / disinfection process, totaling 78 crops. There was no statistical difference between techniques for the removal of organic matter. This study demonstrated that the three surface friction techniques are effective (p <0.05). 2. Twelve samples per surface were collected in 12 days, before and after cleaning / disinfection, totaling 96 samples. The cleaning / disinfection significantly reduced the quantification of adenosine triphosphate and microbial counting of the anesthesia and counter apparatus (p <0.05). The overall rate of cleaned surfaces by visual inspection, microbiological culture and adenosine triphosphate was, before cleaning and disinfection, 37.5%, 10.4% and 12.5%, respectively, and 39.6%, 31, 2% and 70.8% after. 3. Number of samples similar to study 2. Cleaning / disinfection significantly decreased all monitoring parameters for all surfaces. The overall rate of cleaned surfaces by visual inspection, ATP and culture was respectively 47.0%, 37.5% and 22.0% before cleaning and disinfection, and 81.2%, 89.6% and 70.1% after. Conclusions: 1. Further studies considering other indicators and surfaces are needed. 2. The protocol for cleaning / disinfecting operating room surfaces needs to be re-evaluated in order to provide safety to the surgical patient. 3. The elaboration and implementation of the protocol of cleaning / disinfection of the operating room proved to be efficient, since it presented smaller and significant results after the cleaning / disinfection, considering the methods of measurement of the process of cleaning the environmental surfaces. / Introdução: A contaminação das superfícies hospitalares desempenha importante papel na disseminação da infecção relacionada à assistência à saúde. Ainda não há consenso a respeito de como as superfícies ambientais devem ser limpas e/ou desinfetadas, bem como, quais os métodos mais apropriados para avaliar o processo de limpeza/desinfecção. Há diferentes sistemas para monitoramento da eficiência do processo de limpeza de superfícies hospitalares: entre eles, a inspeção visual, marcador fluorescente, adenosina trifosfato por bioluminescência e culturas microbiológicas. Objetivos: 1. Comparar a eficiência de três técnicas de fricção de superfície para redução de matéria orgânica; 2. Avaliar a eficiência da limpeza/desinfecção concorrente de superfícies em sala operatórias; 3. Avaliar a eficiência antes/depois da limpeza/desinfecção de superfícies de sala operatória após revisão e implementação de um protocolo de L/D com ênfase em intervenções educativa e procedimental. Material e Métodos: 1. Estudo quantitativo, descritivo e exploratório, realizado antes e após o processo de limpeza/desinfecção das mesas de cabeceiras da unidade de pacientes. Três técnicas de fricção em sentido unidirecional, bidirecional e centrífuga, foram realizadas individualmente em cada mesa. Para cada unidade de paciente e técnica de fricção, uma única mesa e pano umedecido com álcool a 70% (p/v) foi empregado. A matéria orgânica foi detectada pela presença de adenosina trifosfato por bioluminescência utilizando-se o sistema 3M™ Clean-Trace™ ATP Systems. 2. Estudo correlacional, prospectivo, desenvolvido no interior paulista, no mês de julho de 2014. Amostra não probabilística foi constituída pelas superfícies: mesa cirúrgica, aparelho de anestesia, mesa acessória e balcão sendo avaliadas por inspeção visual, cultura microbiológica e adenosina trifosfato por bioluminescência, na frequência de uma sala operatória por dia. 3. Semelhante ao estudo 2, porém entre os meses de julho a agosto de 2014. Conjuntamente foi realizado, pela enfermeira coordenadora do bloco cirúrgico, intervenção educativa e padronização de procedimentos. Resultados: 1. Para cada técnica, 13 amostras foram coletadas antes/após o processo de limpeza/desinfecção, totalizando 78 colheitas. Não se constatou diferença estatística entre as técnicas na remoção de matéria orgânica. Este estudo demonstrou que as três técnicas de fricção de superfície são eficazes (p<0,05). 2. Foram coletadas em 12 dias, antes e após a limpeza/desinfecção, 12 amostras por superfície, totalizando 96 amostras. A limpeza/desinfecção diminuiu de forma significativa apenas a quantificação de adenosina trifosfato e contagem microbianas do aparelho de anestesia e balcão (p<0,05). A taxa global de superfícies limpas por inspeção visual, cultura microbiológica e adenosina trifosfato foi, respectivamente, antes da limpeza e desinfecção, de 37,5%, 10,4% e 12,5% e, de 39,6%, 31,2% e 70,8% após. 3. Número de amostras semelhante ao estudo 2. A limpeza/desinfecção diminuiu, de forma significativa, todos os parâmetros de monitorização para todas as superfícies. A taxa global de superfícies limpas por inspeção visual, ATP e cultura foi, respectivamente, de 47,0%, 37,5% e 22,0% antes da limpeza e desinfecção, e de 81,2%, 89,6% e 70,1% após. Conclusões: 1. Estudos adicionais considerando outros indicadores e superfícies são necessários. 2. O protocolo de limpeza/desinfecção de superfícies de sala operatórias necessita ser reavaliado a fim de propiciar segurança ao paciente cirúrgico. 3. A elaboração e implementação do protocolo de limpeza/desinfecção da sala operatória se mostrou eficiente, pois apresentou resultados menores e significantes após a limpeza/desinfecção, considerando aos métodos de mensuração do processo de limpeza das superfícies ambientais.
244

Avaliação clínica do efeito de dois métodos de desinfecção sobre a rugosidade, estabilidade de cor e formação de biofilme de próteses reembasadas /

Moffa, Eduardo Buozi. January 2010 (has links)
Orientador: Eunice Teresinha Giampaolo / Banca: Ana Cláudia Pavarina / Banca: Janaina Habib Jorge / Resumo: Este estudo avaliou clinicamente o efeito de dois métodos para limpeza de próteses sobre a rugosidade, estabilidade de cor e a quantificação de micro-organismos de um reembasador rígido em diferentes intervalos de tempo. Foram selecionados 30 pacientes de ambos os gêneros com idade entre 40 e 80 anos, portadores de prótese total superior com necessidade de reembasamento. Essas próteses foram reembasadas com o material Tokuyama Rebase II Fast segundo as recomendações do fabricante. Em seguida, a amostra foi dividida em três grupos (n=10): GC (Grupo Controle) - os pacientes higienizaram suas próteses três vezes ao dia por meio de escovação com sabão de coco; GP (Grupo Perborato) - os pacientes realizaram escovação com sabão de coco e imersão diária da prótese em solução de perborato de sódio durante 5 minutos; GChx (Grupo Clorexidina) - nesse grupo, além da escovação com sabão de coco, foi realizada diariamente a imersão da prótese por 5 minutos em solução de digluconato de clorexidina 2%. Antes da colocação da prótese, os pacientes foram orientados a enxaguá-la adequadamente. A rugosidade superficial e estabilidade de cor do material reembasador foram avaliadas pelo profissional imediatamente após o reembasamento e após 7, 15, 30, 90, e 180 dias. A coleta de microoganismos foi realizada após 7, 15, 30, 90, e 180 dias. A rugosidade superficial foi mensurada através da utilização de um rugosímetro, que fornece valores em Ra-μm. A estabilidade de cor foi avaliada por meio de um espectrofotômetro portátil (BYK - Gardner). Os valores de ΔE obtidos foram comparados utilizando-se a classificação determinada pelo National Bureau of Standards (NBS). Análise de variância de medidas repetidas no tempo (p=0,05) foi empregada na avaliação dos métodos de desinfecção sobre a rugosidade superficial, estabilidade de cor e contagem... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the effect of two disinfection methods for dentures on the clinical performance and quantification of microorganisms of a hard chairside reline resin in different time period. Thirty patients aged between 40 and 80 who required denture reline treatment, participated in this study. Tokuyama Rebase II was used to reline the complete dentures. After that, the edentulous subjects were ramdomly divided into three groups (n=10) and dentures were cleansed according to three methods: CG (control group) - brushing with coconut soap and soft toothbrush; PG (Perborate group) - brushing according to previous methods and disinfection with sodium perborate for 5 minutes once a day during the entire evaluation period (180 days) and ChxG (Chlorhexidine Group) - brushing according to CG and disinfection with chlorhexidine digluconate 2% for 5 minutes once a day during the entire evaluation period (180 days). Surface roughness and color stability were assessed immediately after the relining and after 7, 15, 30, 90 and 180 days of treatment. Quantitative microbial cultures were taken from the tissue side of each maxillary denture after 7, 15, 30, 90 and 180 days of dentures disinfection. The surface roughness was measured using a roughnes meter, which provides values in Ramicrometers. The color stability was evaluated by means of a portable espctrofotômetro (BYK - Gardner). The ΔE values were compared using the classification determined by the National Bureau of Standards (NBS). Analysis of variance for repeated measures (p = 0.05) were used in the evaluation of disinfection methods on the surface roughness, color stability and microbial counts (cfu / ml). The analysis of variance with repeated measures identified a significant effect only on the time factor (p <0.001) for the values of surface roughness, discoloration and microbial quantification... (Complete abstract click electronic access below) / Mestre
245

Comportamento de sistemas pós-filtros adsorvedores na remoção de compostos orgânicos precursores e subprodutos da desinfecção. / Behavior of post-filter adsorbers in the removal of organic precursors and disinfection byproducts.

Claudia Mota Santos Pereira 14 August 2009 (has links)
O presente trabalho teve como objetivo avaliar a eficiência de pós-filtros adsorvedores constituídos de Carvão Ativado Granular (CAG) na remoção de compostos orgânicos precursores e na formação de subprodutos da desinfecção, em particular dos trialometanos (THM) na Estação de Tratamento de Água Alto da Boa Vista (ETA ABV), abastecida por reservatórios de água bruta com elevado grau de eutrofização. Os ensaios foram conduzidos em ETA Piloto composta por tanque de reservação de água filtrada, ozonizador, tanque de reservação de água ozonizada e 4 pós-filtros adsorvedores, sendo duas unidades dotadas de CAG de origem mineral e duas unidades dotadas de CAG de origem vegetal. Os filtros foram operados em paralelo, sendo que duas colunas foram alimentadas com água filtrada da ETA ABV (Filtro F3 CAG de origem mineral e Filtro F4 CAG de origem vegetal) e as outras duas alimentadas com água filtrada e ozonizada (Filtro F1 CAG de origem mineral e Filtro F2 CAG de origem vegetal). A avaliação da remoção de compostos orgânicos precursores e formação de subprodutos da desinfecção foi feita através de análises de carbono orgânico total (COT), UV-254 nm e formação de THM. A análise dos resultados gerados de julho de 2007 a dezembro de 2008 permitiu concluir que 93% do THM é formado nas primeiras 24 horas de contato da amostra com o cloro, simulando a pós cloração e pós alcalinização da ETA ABV. O processo de oxidação por ozônio não foi efetivo na remoção de THM instantâneo, visto que a média dos 38 valores de THM instantâneo para a água filtrada (17,8 ± 5,6 g/L) foi igual a média obtida para o THM instantâneo na água ozonizada. A remoção de THM pelos filtros de CAG foi mais significativa nos primeiros três meses de operação do sistema, apresentando remoção de 80% para os filtros com CAG de origem mineral e 70% para os filtros com CAG de origem vegetal, a partir do quarto mês de operação do sistema a remoção de THM caiu para um valor médio de 34%, o que mostra uma iminente saturação do leito adsorvedor. Os pós-filtros adsorvedores constituídos de CAG de origem mineral apresentaram melhor comportamento com respeito a remoção de THM e COT quando comparado com os pós-filtros dotados de CAG de origem vegetal. / The main purpose of this work was to evaluate the performance of a Granular Activated Carbon (GAC) post-filter adsorbers in the removal of organic precursors and in the formation of disinfection byproducts, especially trihalomethanes (THM) in Alto da Boa Vista Water Treatment Plant (ABV WTP), which takes raw water from a highly eutrophized reservoirs. The tests was conducted on a Pilot WTP composed of filtered water tank, ozonator, ozonized water tank, and four post-filter adsorbers: two units with mineral GAC media and two units with vegetal GAC media. The filters were operated in parallel, with two columns fed with filtered water from ABV WTP (F3 Filter mineral GAC and F4 Filter vegetal GAC) and the other fed with ozonized water (F1 Filter mineral GAC and F2 Filter vegetal GAC). The evaluation of the removal of organic precursors and the formation of disinfection byproducts was made through analysis of Total Organic Carbon (TOC), UV-254 nm and THM formation. The results generated from July 2007 to December 2008 showed that 93% of THM is formed in the first 24 hours of contact with the chlorine in the sample, simulating the post chlorination and post alkalinization of ABV WTP in samples of filtered water, ozonized water, and post-filter adsorbers effluent. Ozone oxidation process was not effective in removing THM. Was found the same instantaneous THM values in the filtered water (17.8 g/L± 5.6 g/L) and in the ozonized water. During the first three months of post-filter adsorber operation, THM removal efficiencies were around 80% for F1 and F3 (mineral GAC media) and around 70% for F2 and F4 (vegetal GAC media). After four months of operation, THM removal efficiencies decreased to 34% average value, thus indicative of GAC saturation. Regarding THM and TOC removal efficacy, the mineral GAC performed better than the vegetal GAC.
246

AVALIAÇÃO DO PROCESSO FOTOCATALÍTICO NA DESINFECÇÃO DE EFLUENTES ANAERÓBIOS DE ÁGUAS RESIDUÁRIAS

Reinaldo, Myrthis Virgínia Alves de Almeida 23 February 2006 (has links)
Made available in DSpace on 2015-09-25T12:23:34Z (GMT). No. of bitstreams: 1 MyrthisVirginiaAlvesDeAlmeidaReinaldo.pdf: 991886 bytes, checksum: b2a23283e6671d15e111f946866efab9 (MD5) Previous issue date: 2006-02-23 / This research was accomplished with the purpose of studying the acting of a process developed for environmental disinfection, contributing for disinfection of wastewaters from anaerobic treatment systems of sanitary sewers. This process used the heterogeneous photocatalysis, that consists of the oxidation of organic pollutants through the generation of radicals hidroxila ( OH), highly oxidizers, which is gotten with the aid of a semiconductor and a UV radiation source. The semiconductor was the titanium dioxide (TiO2) and the source of energy from artificial luminous source (UV lamp) and natural (Sun) of ultraviolet radiation. Two types of reactors were used: a reactor type concentric tubes containing a 15W bactericidal UV lamp inside, treating wastewaters coming of two systems: UASB and Anaerobic Filter of Chicanes, with a flow of recirculation of 72 L.h-1 for 2 hours. In this reactor was made experiments with and without TiO2 in suspension. And a TiO2 impregnated plate reactor, treating wastewater of the anaerobic filter of chicanes, working in four different flow of recirculation: 13,2L.h-1, 25L.h-1, 42L.h-1 and 75L.h-1, for 4 hours of exposed to the sunlight. For both were evaluated the removal efficiencies of the fecal contamination indicative microorganisms - thermotolerants coliforms, and the rate of bacterial inativation through the study of the kinetic constant (k) and analyzed the physical and chemical parameters corresponding to the variation of the temperature, pH, electric conductivity (CE), total alkalinity and to bicarbonate, total nitrogen Kjeldahl (TNK), ammonia (NH3), total phosphor and orthophosphate, solids and your fractions, volatile greasiest acids (AGV) and removal of the organic matter (QDO). The kinetics study of the bacterial inativation (k) it revealed the best acting, in the concentric tubes reactor, for the experiment with photocatalysis using the anaerobic filter of chicanes wastewater. Already in the impregnated plate reactor, the best acting was observed in the 25L.h-1 flow, with 100% thermotolerants coliforms removed. The experiment with impregnated plate reactor it was shown efficient in the removal of the nitrogen compounds TNK and Ammonia. The smallest removal efficiency of thermotolerants coliforms of the UASB wastewater, in the concentric tubes reactor, was due to the high concentration of solids in suspension of the secondary wastewater, what block the uniformity of the UV radiation penetration. High evaporation rates, frequent in the experiments with the impregnated plate reactor, they caused increase in the final concentration of some parameters. The process of the heterogeneous photocatalysis is an efficient alternative method for the disinfection of tertiary wastewater with low concentration of solids in suspension. / Esta pesquisa foi realizada com a finalidade de estudar o desempenho de um processo desenvolvido para descontaminação ambiental, contribuindo para a desinfecção de efluentes de sistemas de tratamento anaeróbio de esgotos sanitários. Este processo foi o da fotocatálise heterogênea, que consiste na oxidação de contaminantes orgânicos através da geração de radicais hidroxila ( OH), altamente oxidantes, e que é conseguido com o auxílio de um fotocatalisador, no caso um semicondutor, e uma fonte de radiação UV. O semicondutor utilizado foi o dióxido de titânio (TiO2) e a fonte de energia luminosa proveniente de fonte artificial (lâmpada UV) e natural (Sol) de radiação ultravioleta. Foram utilizados dois tipos de reatores: um reator do tipo tubos concêntricos contendo uma lâmpada UV germicida 15W em seu interior, tratando efluentes provenientes de dois sistemas: UASB e filtro anaeróbio de chicanas, com uma vazão de recirculação de 72 L.h-1 durante 2 horas, com os quais foram feitos experimentos com e sem a utilização do TiO2 em suspensão; e um reator de placa impregnada com TiO2, tratando efluente do filtro anaeróbio de chicanas, trabalhando em quatro diferentes vazões de recirculação: 13,2 L.h-1, 25 L.h-1, 42 L.h-1 e 75 L.h-1, durante 4 horas de exposição à luz solar. Para ambos os reatores foram avaliadas as eficiências de remoção dos microrganismos indicadores de contaminação fecal os coliformes termotolerantes, como também a taxa de inativação bacteriana através do estudo da constante cinética (k) e analisados os parâmetros físico e químicos correspondentes à variação da temperatura, pH, condutividade elétrica (CE), alcalinidade total e a bicarbonato, nitrogênio total Kjeldahl (NTK), nitrogênio amoniacal (NH3), fósforo total e ortofosfato, sólidos e suas frações, ácidos graxos voláteis (AGV) e remoção de matéria orgânica (DQO). O estudo da constante cinética de inativação bacteriana (k) revelou o melhor desempenho, no reator de tubos concêntricos, para o experimento com fotocatálise utilizando o efluente do filtro anaeróbio de chicanas. Já no reator de placa impregnada, o melhor desempenho foi observado na vazão de 25L.h-1, com 100% dos coliformes termotolerantes removidos. O experimento com o reator de placa impregnada mostrou-se eficiente na remoção dos compostos nitrogenados NTK e N-amoniacal. A menor eficiência de remoção de coliformes termotolerantes do efluente do reator UASB, no reator de tubos concêntricos, deveu-se à alta concentração de sólidos em suspensão do efluente secundário, o que impede a uniformidade da penetração da radiação UV. Elevadas taxas de evaporação, freqüentes nos experimentos com o reator de placa impregnada, provocaram aumento na concentração final de alguns parâmetros. O processo da fotocatálise heterogênea é um método alternativo eficiente para a desinfecção de efluentes terciários com baixa concentração de sólidos em suspensão.
247

Fotocatálise heterogênea com Ti'O IND.2' aplicada ao tratamento de esgoto sanitário secundário / Ti'O IND.2' heterogeneous photocatalysis in secondary wastewater treatment

Ferreira, Ivete Vasconcelos Lopes 16 December 2005 (has links)
Este trabalho teve como objetivo estudar a fotocatálise heterogênea com Ti'O IND.2' no tratamento de esgoto sanitário secundário, visando a oxidação da matéria orgânica e desinfecção. A luz solar foi utilizada como fonte de radiação. O reator fotocatalítico consistiu de placa de vidro (aproxidamente 0,48 'M POT.2') sobre a qual foi fixado o catalisador (10 g/'M POT.2'). Foi avaliada a influência de parâmetros operacionais (vazão e ângulo de inclinação do fotorreator) na eficiência do processo. As vazões de estudo foram 15; 22,5 e 30 L/h, e os ângulos de inclinação em relação à horizontal foram 2, 12 e 22 graus. Os experimentos foram realizados com dois tipos de efluentes. O primeiro (efluente 1) foi de reator anaeróbio compartimentado tratando esgoto doméstico e o segundo (efluente 2) de reator anaeróbio/aeróbio de leito expandido com meio suporte constituído de carvão ativado que trata o esgoto do Campus I da USP/São Carlos e de contribuições domésticas. Os ensaios foram do tipo batelada com recirculação do esgoto durante 4 horas. Também foi avaliada a fotólise (ensaio apenas com radiação solar) e adsorção do catalisador (ensaio sem luz e com Ti'O IND.2') na oxidação de matéria orgânica e na desinfecção. Foram avaliadas as remoções de matéria orgânica (DQO e COT) e de microrganismos indicadores de contaminação fecal (Clostridium perfringens, coliformes totais, E. coli e colifagos). Os resultados indicaram que a fotocatálise heterogênea foi mais eficiente como método de desinfecção que a fotólise. A resistência dos microrganismos ao processo Ti'O IND.2'/UV, em ordem decrescente, foi: Clostridium perfringens, coliformes totais, E. coli e colifagos. As melhores condições operacionais para inativação de microrganismos no efluente 1 foram: 'alfa' = 2 graus e Q = 22,5 L/h. O ângulo de inclinação da placa teve maior influência na oxidação de COT do efluente 2 do que a vazão. As características físico-químicas dos efluentes tiveram papel importante no resultado final da fotocatálise heterogênea, tanto na oxidação de matéria orgânica como na desinfecção. A concentração inicial de E. coli exerceu maior influência na desinfecção fotocatalítica do que a radiação solar, para as condições dos ensaios realizados. Os reatores de placa plana com Ti'O IND.2' imobilizado, quando expostos à luz solar, devem ser vedados para evitar evaporação excessiva / The heterogeneous photocatalysis with Ti'O IND.2' and solar radiation in secondary wastewater treatment to remove organic matter and microorganisms was investigated. A glass plate (approximate 0.48 'M POT.2') with immobilized titanium dioxide (10 g/'M POT.2') was operated in different flow rates (15; 22.5 and 30 L/h) and angles in relation to horizontal (2, 12 and 22 degrees). Two effluents were used in the assays. The first (effluent 1) was from an anaerobic reactor treating sewage and the second (effluent 2) from an anaerobic/aerobic granular activated carbon expanded bed reactor which receives the wastewater collected in the Campus of USP/São Carlos and from the surrounding neighborhood of the campus. The assays were carried out in batch with recirculation time of 4 hours. The photolysis (only solar radiation) and the catalyst adsorption (Ti'O IND.2' in the dark) in organic matter removal and disinfection were evaluated. The oxidation of organic matter (COD and TOC) and inactivation of indicators of fecal contamination (Clostridium perfringens, total coliforms, E. coli, and coliphages) were evaluated. The results shows that heterogeneous photocatalysis was more efficient in effluents disinfection than the photolysis. The resistance of the microorganisms to Ti'O IND.2'/UV process was in decreasing order: Clostridium perfringens, total coliforms, E. coli and coliphages. The best operational conditions for microorganisms inactivation in effluent 1 are: 'alfa' = 2 degrees and Q = 22.5 L/h. TOC oxidation in effluent 2 was more influenced by angle than by flow rate. The physical and chemical characteristics of the effluents had an important role in oxidation and disinfection. Initial E. coli concentration was more important than intensity of solar radiation during photocatalytic disinfection in the experimental conditions of this work. The reactors with immobilized Ti'O IND.2' open to solar radiation have to be closed to avoid excessive evaporation
248

Construção de Procedimento Operacional Padrão para Desinfecção de Superfícies Ambientais em Bloco Cirúrgico

Serafim, Williany Dark Silva January 2019 (has links)
Orientador: Ione Correa / Resumo: Introdução: O bloco cirúrgico ou bloco operatório é classificado como um setor crítico e complexo, com a capacidade de atender as necessidades da prática cirúrgica. Estratégias ambientais são componente essencial para prevenir infecções associadas aos cuidados de saúde. Objetivo: Analisar as evidências científicas sobre a desinfecção de superfícies ambientais em bloco cirúrgico, com uma proposta de construção de um procedimento operacional padrão. Método: Revisão integrativa da literatura com artigos em português, inglês, espanhol nas bases de dados LILACS (via portal Bireme), BDENF, MEDLINE, PubMed, Scopus, SciELO, Web of Science. Os critérios de inclusão foram artigos publicados em periódicos e disponíveis na íntegra, inglês, português ou espanhol que abordassem a temática e sem limitação temporal. Resultados e Discussão: Foram analisados três artigos, dois (66%) foram encontrados na base de dados Medline e um (34%) na Lilacs. Em relação a formação profissional dos autores, dois (66%) eram médicos e um artigo (34%) foi produzido por um enfermeiro. Quanto ao ano de publicação houve uma correlata aproximação de anos. Em relação ao local de estudo, periódico e seu respectivo Qualis, as publicações foram distribuídas em: um (34%) periódico nacional publicado em Uberlândia – MG e dois (66%) periódicos nacionais pulicados em Miami e Texas – USA respectivamente; os três artigos foram publicados em periódicos de grande impacto, sendo o artigo nacional (34%) publicado pela Revista L... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Introduction: The surgical block or operative block is classified as a critical and complex sector, with the capacity to meet the needs of the surgical practice. Environmental strategies are an essential component in preventing infections associated with health care. Objective: To analyze the scientific evidence on the disinfection of environmental surfaces in a surgical block, with a proposal to construct a standard operating procedure. Method: Integrative literature review with articles in Portuguese, English and Spanish in the LILACS (via Bireme portal), BDENF, MEDLINE, PubMed, Scopus, SciELO, Web of Science. The inclusion criteria were articles published in periodicals and available in full, English, Portuguese or Spanish that approached the theme and without temporal limitation. Results and Discussion: Three articles were analyzed, two (66%) were found in the Medline database and one (34%) in Lilacs. Regarding the professional training of the authors, two (66%) were doctors and one article (34%) was produced by a nurse. As for the year of publication there was a correlata approximation of years. The publications were distributed in: one (34%) national periodical published in Uberlândia - MG and two (66%) national journals published in Miami and Texas - USA respectively; (34%) published by the Revista Latino Americana de Enfermagem (Revista Latino Americana de Enfermagem) with the stratum indicative of Qualis A1, and the international papers (66%) were published by Infect... (Complete abstract click electronic access below) / Mestre
249

Efetividade da irradiação por microondas na desinfecção de próteses totais contaminadas por diferentes espécies de Candida isoladas de pacientes HIV positivo

Sanitá, Paula Volpato [UNESP] 26 March 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:38Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-03-26Bitstream added on 2014-06-13T19:16:49Z : No. of bitstreams: 1 sanita_pv_me_arafo.pdf: 1236296 bytes, checksum: 793fd4710489b2253297ebbc15835736 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A estomatite protética associada à Candida é a forma mais comum de candidíase oral e também uma das infecções oportunistas mais encontradas em pacientes infectados por HIV. Atualmente, a desinfecção de próteses totais através da irradiação por microondas tem sido recomendada para tratamento e prevenção da estomatite protética, tanto em indivíduos saudáveis, quanto em pacientes imunocomprometidos. O presente estudo avaliou a efetividade da irradiação por microondas na desinfecção de próteses totais simuladas contaminadas com 5 diferentes espécies do microorganismo Candida (C. albicans, C. glabrata, C. dubliniensis, C. tropicalis e C. krusei) isoladas de culturas padrão e de pacientes HIV positivo. Para isso, próteses totais simuladas foram confeccionadas, esterilizadas por meio de óxido de etileno e individualmente inoculadas com os microorganismos avaliados. Após o período de incubação (48 horas a 37°C), as próteses foram submetidas à irradiação por microondas a 650W durante 3 minutos. Próteses totais não irradiadas foram utilizadas como controle positivo. A seguir, uma alíquota de 25 æL da solução resultante das diluições seriadas de 10-1 a 10-4 foi semeada em placas de Petri em duplicata e todas as placas foram incubadas por 48 horas a 37°C. As colônias foram quantificadas em ufc/mL. Para verificar a efetividade da desinfecção por microondas a longo prazo, as próteses totais irradiadas foram incubadas a 37°C por 7 dias. Os resultados obtidos foram analisados estatisticamente pelos testes de ANOVA e de Tukey (a=0.05). As próteses totais contaminadas com todas as espécies de Candida avaliadas demonstraram esterilização após irradiação por microondas durante 3 minutos a 650W. Todas as próteses do grupo controle positivo demonstraram crescimento microbiológico após incubação nas placas de Petri. / The most common form of oral candidiasis is Candida-associated denture stomatitis. Oral candidiasis is also a frequent manifestation of HIV infection. Microwave disinfection of complete dentures has been recommended to treat and prevent denture stomatitis in non-immune compromised patients. The present study evaluated the effectiveness of microwave irradiation on the disinfection of simulated complete dentures inoculated with ATCC and HIV isolates of 5 species of Candida (C. albicans, C. glabrata, C. dubliniensis, C. tropicalis and C. krusei). Simulated complete dentures were made, sterilized and individually inoculated with the tested microorganisms. After incubation for 48 hours at 37°C, dentures were submitted to microwave irradiation (650W for 3 minutes). Non-irradiated dentures were used as positive controls. Replicate aliquots of suspensions were plated at dilutions 10-1-10-4 and incubated for 48 hours at 37°C. Colonies counts (cfu/mL) of each plate were quantified. To verify the long-term effectiveness of microwave disinfection, dentures were incubated at 37°C for 7 days. Data were analyzed with two-way ANOVA and Tukey HSD tests (a=0.05). The results indicated that complete dentures contaminated with all Candida yeasts showed sterilization after microwave irradiation for 3 minutes at 650W. All control dentures showed microbial growth on the plates. The cfu/mL for C. glabrata was significantly higher than those of C. albicans, C. dubliniensis and C. tropicalis whereas the cfu/mL for C. krusei was significantly lower. The cfu/mL for clinical isolates was significantly higher than those of ATCC yeasts. Microwave irradiation for 3 minutes at 650W resulted in sterilization of complete dentures contaminated with the 5 species of Candida isolated from HIV-infected patients.
250

Efetividade de duas soluções desinfetantes e da irradiação por micro-ondas na desinfecção de próteses totais contaminadas com staphylococcus aureus resistente à meticilina (MRSA)

Altieri, Karen Tereza [UNESP] 28 March 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:38Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-03-28Bitstream added on 2014-06-13T20:18:32Z : No. of bitstreams: 1 altieri_kt_me_arafo.pdf: 598917 bytes, checksum: 3b01564a77c1be4471454056881b7028 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Infecções causadas por bactérias resistentes a antibióticos são consideradas causa principal de mortalidade entre indivíduos imunocomprometidos e aproximadamente 50 % destas infecções tem sido relacionadas ao Staphylococcus aureus resistente à meticilina (MRSA). Estes microrganismos, quando presentes no biofilme das próteses dentarias, podem se dispersar nas secreções salivares e se disseminar pelo trato respiratório, causando pneumonia aspirativa. Assim, o presente estudo comparou a efetividade do hipoclorito de sódio a 1 %, digluconato de clorexidina a 2 % e irradiação por micro-ondas na desinfecção de próteses totais e corpos-de-prova circulares de resina acrílica para base de prótese (10 x 2 mm) contaminados com MRSA. Para isso, 36 próteses totais simuladas e 36 corpos-de-prova circulares foram confeccionados, esterilizados, inoculados com MRSA (107 ufc/mL) e incubados a 37 °C (por 24 e 48 h, respectivamente). Após incubação, próteses totais e corpos-de-prova foram distribuídos em 4 grupos de estudo (n=9): GC - não foi realizado nenhum método de desinfecção; GH - foi realizada a imersão em solução de hipoclorito de sódio a 1 % por 10 min; GCl -foi realizada a imersão em solução de digluconato de clorexidina a 2 % por 10 min; GM - foi realizada a desinfecção por irradiação em forno de micro-ondas a 650 W por 3 min. A efetividade dos procedimentos de desinfecção foi avaliada por meio de quantificação de colônias viáveis e da viabilidade celular. Para a quantificação de colônias viáveis, alíquotas de 25 μL da solução resultante das diluições seriadas (10-3 a 10-6 para GC e 100 a 10-3 para os grupos experimentais) foram semeadas em placas de Petri em duplicata e todas as placas foram incubadas por 48 h a 37 °C. As colônias foram quantificadas em ufc/mL. Para verificar a efetividade da desinfecção por micro-ondas em longo prazo... / Infections caused by antibiotic-resistant bacteria have been recognized as a predominant risk factor for mortality in elderly patients and approximately 50 % of these infections have been related to methicillin-resistant Staphylococcus aureus (MRSA). This microorganism, when present in the denture biofilm, can be released into the oral fluids and aspirated into the lower respiratory tract, thus causing infections such as aspiration pneumonia. The present study compared the efficacy of 1 % sodium hypochlorite, 2 % chlorhexidine gluconate, and microwave irradiation in disinfecting simulated complete dentures and circular specimens of acrylic resin denture base material (10 x 2 mm) contaminated with MRSA. Thirty-six dentures and 36 specimens were made, sterilized, inoculated with MRSA (107 cfu/mL), and incubated at 37 °C (for 24 and 48 h, respectively). After incubation, dentures and specimens were divided into 4 groups of study (n=9): PC - positive control, consisting of dentures and specimens not disinfected; HY - soaking in 1 % sodium hypochlorite solution for 10 min; CHL - soaking in 2 % chlorhexidine gluconate solution for 10 min; and MW - irradiating by microwave for 3 min at 650W. The effectiveness of the disinfection procedures was assessed cell viability (quantification of viable cells and XTT reduction method). For quantification procedures, aliquots of suspensions were plated at dilutions (10-3 to 10-6 for PC and 100 to 10-3 for experimental groups) and incubated (37 °C/48 h). Colonies counts (cfu/mL) were quantified. Dentures disinfected were also incubated at 37 °C for 7 days to verify the long-term effectiveness of disinfection. The viability of cells in each group of specimens was evaluated by XTT reduction method. The results showed that all dentures and specimens from the PC groups showed substantial microbial growth. No evidence of microbial growth was observed... (Complete abstract click electronic access below)

Page generated in 1.5389 seconds