• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 341
  • 4
  • 4
  • 4
  • 4
  • 3
  • 2
  • 1
  • Tagged with
  • 346
  • 146
  • 70
  • 65
  • 56
  • 56
  • 46
  • 41
  • 39
  • 37
  • 37
  • 34
  • 28
  • 28
  • 27
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
321

Estudo clínico randomizado para avaliação da segurança e dos efeitos da estimulação ventricular esquerda unifocal em pacientes com bradiarritmias / Randomized clinical trial for eficaccy, safety and performance of of isoleted left ventricular pacing in patients with bradyarrhythmias

Crevelari, Elizabeth Sartori 31 August 2018 (has links)
Introdução: Considerando-se os potenciais efeitos deletérios da estimulação do ventrículo direito (VD), a hipótese desse estudo é que a estimulação unifocal ventricular esquerda (VE) pelo seio coronário é segura e pode proporcionar melhores benefícios clínicos e ecocardiográficos aos pacientes com bloqueio atrioventricular e função ventricular esquerda preservada ou pouco alterada, necessitando apenas da correção da frequência cardíaca. Objetivos: Avaliar a segurança, a eficácia e os efeitos da estimulação ventricular esquerda, utilizando um cabo-eletrodo com fixação ativa, em comparação à estimulação ventricular direita em pacientes com indicação de marca-passo (MP) convencional e função ventricular esquerda normal a moderadamente alterada. Métodos: Trata-se de um estudo clínico, randomizado, simples-cego que incluiu pacientes adultos com indicação de MP convencional por bloqueio atrioventricular avançado e função ventricular sistólica >= 0,40. A randomização aleatória (VD vs. VE) ocorreu antes do procedimento. Os desfechos primários do estudo foram o sucesso, a segurança e a eficácia do procedimento proposto. Os desfechos secundários foram a evolução clínica e alterações ecocardiográficas. Foram empregados os testes qui-quadrado, exato de Fisher e teste t de Student para comparação dos desfechos entre os dois grupos, considerando o nível de significância de 5%. Resultados: De junho de 2012 a janeiro de 2014 foram incluídos 91 pacientes, sendo 36 no grupo VD e 55 no grupo VE. As características basais dos pacientes dos dois grupos foram similares (P = NS). O implante de MP foi realizado com sucesso e sem nenhuma intercorrência em todos os pacientes do grupo VD. No grupo VE, entretanto, dos 55 pacientes inicialmente alocados, o implante do cabo-eletrodo em veias coronárias não foi possível em 20 (36,4%) pacientes. Complicações pós-operatórias foram detectadas apenas no grupo VE. A complicação mais frequente foi a estimulação frênica, detectada em 9 (25,7%) pacientes. Durante o período de seguimento do estudo, não houve hospitalizações por insuficiência cardíaca. Reduções superiores a 10% na fração de ejeção do ventrículo esquerdo foram observadas em 23,5% dos pacientes do grupo VD e em 20,6% dos do grupo VE (P = 0,767). A análise feita pelo Doppler tecidual mostrou que 55,9% dos indivíduos do grupo VD e 43,8% dos do grupo VE apresentaram dissincronia intraventricular ventricular esquerda (P = 0,324). Pelo mesmo método, foi detectado que 91,2% e 68,8% dos pacientes dos grupos VD e VE, respectivamente, apresentavam dissincronia interventricular (P=0,022). Conclusões: A estimulação ventricular esquerda exclusiva, nas condições estudadas, mostrou taxa de sucesso, segurança e eficácia inadequadas. A despeito da melhor sincronia interventricular observada nos pacientes sob estimulação ventricular esquerda, a comparação dos desfechos secundários entre os dois grupos não mostrou diferenças significativas / Background: Considering the potential deleterious effects of right ventricular (RV) pacing, the hypothesis of this study is that isolated left ventricular (LV) pacing through the coronary sinus is safe and may provide better clinical and echocardiographic benefits to patients with bradyarrhythmias and normal ventricular function requiring only the correction of heart rate. Objective: To assess the safety, efficacy and effects of LV pacing using an active-fixation coronary sinus lead compared to RV pacing in patients eligible to conventional pacemaker (PM) implantation. Methods: Randomized, controlled and single-blinded trial in adult patients submitted to PM implantation due to bradyarrhythmias and systolic ventricular function >= 0.40. Randomization (RV vs LV) occurred before PM implantation. Procedural success, safety, and efficacy were the main endpoints. Secondary outcomes were clinical and echocardiographic changes. Chi-square, Fisher\'s exact test and Student\'s t test were used, considering a significance level of 5%. Results: From June/2012 to January/2014, 91 patients were included, 36 in the RV group and 55 in the LV group. Baseline characteristics of patients in both groups were similar. PM implantation was performed successfully and without any complications in all patients in the RV group. Of the 55 patients initially allocated to the LV group, the implant of the active-fixation coronary sinus lead was not possible in 20 (36.4%) patients. The most frequent complication was phrenic nerve stimulation, detected in 9 (25.7%) patients in the LV group. During the follow-up period, there were no hospitalizations for heart failure. Reductions of more than 10% in left ventricular ejection fraction were observed in 23.5% of patients in the RV group and in 20.6% of those in the LV group (P= 0.767). Echo-tissue doppler showed that 91.2% of subjects in the RV group and 68.8% of those in the LV group had interventricular dyssynchrony (P= 0.022). Conclusion: Isolated left ventricular pacing, under the conditions studied, showed an inadequate success rate, safety and efficacy. Despite the better interventricular synchrony observed in LV group, the comparison of secondary outcomes between the two groups did not show significant differences
322

Estudo do aumento do desempenho de um sistema de tomografia de impedância elétrica através do método de otimização topológica. / Increasing electrial impedance tomography system performance through the topology optimization method.

Mello, Luís Augusto Motta 27 January 2010 (has links)
A Tomografia de Impedância Elétrica é uma técnica de obtenção de imagens do interior de um corpo, mediante grandezas elétricas medidas em sua superfície. Matematicamente, a técnica determina as distribuições de condutividades e permissividades elétricas num dado modelo do corpo, as quais reproduzem as medidas de correntes e potenciais elétricos em eletrodos fixados ao corpo. Nesse caso, as distribuições de condutividades e permissividades representam a solução de um problema não-linear e mal-posto, o qual é instável e apresenta mínimos locais, requerendo técnicas de inversão específicas. Um sistema de Tomografia de Impedância Elétrica aplicado à obtenção de imagens de valores absolutos possui, atualmente, limitações. São algumas delas a obtenção de distribuições de propriedades suaves e de valores geralmente subestimados, a sensibilidade elevada ao erro de posicionamento dos eletrodos (com relação ao modelo) e ao erro nos valores de parâmetros de contato, a sensibilidade elevada aos ruídos de medição, os tempos elevados de processamento, dentre outros. Com o intuito de abordar as limitações, melhorando o desempenho do sistema de Tomografia de Impedância Elétrica de imagens absolutas, são então propostas e avaliadas ferramentas baseadas no Método de Otimização Topológica no atual trabalho. Mais especificamente, avaliam-se: 1) um método para obtenção de parâmetros de contato em conjunto com uma imagem e um método de regularização baseado no controle explícito da variação espacial da imagem, 2) uma formulação para acomodação de incertezas, 3) uma formulação para correção do posicionamento de eletrodos, 4) uma formulação para projeto de eletrodos e 5) um novo solucionador de sistemas lineares de larga escala. Os resultados mostram a efetividade da maioria das técnicas propostas, e sugerem os novos tópicos de pesquisa em Tomografia de Impedância Elétrica. / Electrical Impedance Tomography images the interior of a body based on electrical quantities measured on the surface of it. Mathematically, the technique finds the electric admittivity distribution in a given body model which reproduces the boundary measurements of electric currents and potentials on electrodes attached to that body. Therefore, the admittivity distribution is the solution of a non-linear and ill-posed problem, which is unstable and have local minima, requiring specific inversion techniques. Electrical Impedance Tomography systems which obtain images corresponding to absolute values present limitations. For instance, the results are usually smooth and underestimated, the sensitivity to errors in the positioning of electrodes and wrong values of contact parameters and the sensitivity to measurement noise are high, the data processing time is high, etc. In this work, techniques based on the Topology Optimization Method intended for improving the performance of the particular Electrical Impedance Tomography system applied to absolute images are proposed and evaluated. More specifically, the following techniques are evaluated: 1) a method intended to obtain contact parameters together with images, and a regularization method based on the explicit control of the spatial variation regarding the image, 2) a formulation applied to handle uncertainties, 3) a formulation applied to correct the position of electrodes, 4) a formulation applied to design electrodes, 5) and a new solver for large-scale linear systems. Results show the effectiveness of most of the proposed techniques, and suggest new research topics in Electrical Impedance Tomography.
323

Estudo e desenvolvimento de conjuntos membrana-eletrodos (MEA) para célula a combustível de eletrólito polimérico condutor de prótons (PEMFC) com eletrocatalisadores à base de paládio / Study and development of membrane electrode assemblies for proton exchange membrane fuel cell (PEMFC) with palladium based catalysts

Bonifacio, Rafael Nogueira 19 November 2013 (has links)
Sistemas de PEMFC são capazes de gerar energia elétrica com alta eficiência e baixa ou nenhuma emissão de poluentes, porém questões de custo e durabilidade impedem sua ampla comercialização. Nesse trabalho foi desenvolvido um MEA com eletrocatalisadores à base de paládio. Foram sintetizados e caracterizados eletrocatalisadores Pd/C, Pt/C e Ligas PdPt/C com diferentes razões entre metais e carbono. Foi realizado um estudo da razão entre ionômero de Nafion e eletrocatalisador para formação de triplas fases reacionais de máximos desempenhos, criado um modelo matemático para transpor esse ajuste para eletrocatalisadores com diferentes razões entre metal e suporte, considerando os aspectos volumétricos da camada catalisadora, e então realizado um estudo da espessura da camada catalisadora. Para as caracterizações foram utilizadas as técnicas de Difração de Raios-X, Microscopias Eletrônicas de Transmissão e de Varredura, Energia Dispersiva de Raios-X, Picnometria a Gás, Porosimetria por Intrusão de Mercúrio, Adsorção de Gás, segundo as equações de BET e BJH, Análise Termo Gravimétrica e feitas as determinações de diâmetros de partículas, de áreas de superfície específica e de parâmetros de rede. Todos os eletrocatalisadores foram usados no preparo de MEAs que foram avaliados em célula unitária de 5 cm2 entre 25 e 100 °C a 1 atm; e a melhor composição foi avaliada também a 3 atm. No estudo dos metais para as reações, visando reduzir a platina aplicada aos eletrodos, sem perdas de desempenho, foram selecionados Pd/C para ânodos e PdPt/C 1:1 para cátodos. A estrutura de MEA desenvolvida utilizou 0,25 mgPt.cm-2 e resultou em densidades de potência de até 550 mW.cm-2 e potências de até 2,2 kWe por grama de platina. A estimativa realizada mostrou que houve uma redução de até 64,5 % nos custos em relação à estrutura de MEA previamente conhecida. Em função da temperatura e pressão de operação foram obtidos valores a partir de R$ 3.540,73 para o preparo de MEAs para cada quilowatt instalado. Com base em estudos recentes, concluiu-se que o custo do MEA desenvolvido é compatível às aplicações estacionárias de PEMFC. / PEMFC systems are capable of generating electricity with high efficiency and low or no emissions, but durability and cost issues prevent its large commercialization. In this work MEA with palladium based catalysts were developed, Pd/C, Pt/C and alloys PdPt/C catalysts with different ratios between metals and carbon were synthesized and characterized. A study of the ratio between catalyst and Nafion Ionomer for formation of high performance triple-phase reaction was carried out, a mathematical model to implement this adjustment to catalysts with different relations between metal and support taking into account the volumetric aspects of the catalyst layer was developed and then a study of the catalyst layer thickness was performed. X-ray diffraction, Transmission and Scanning Electron Microscopy, X-ray Energy Dispersive, Gas Pycnometry, Mercury Intrusion Porosimetry, Gas adsorption according to the BET and BJH equations, and Thermo Gravimetric Analysis techniques were used for characterization and particle size, specific surface areas and lattice parameters determinations were also carried out. All catalysts were used on MEAs preparation and evaluated in 5 cm2 single cell from 25 to 100 °C at 1 atm and the best composition was also evaluated at 3 atm. In the study of metals for reactions, to reduce the platinum applied to the electrodes without performance losses, Pd/C and PdPt/C 1:1 were selected for anodes and cathodes, respectively. The developed MEA structure used 0,25 mgPt.cm-2, showing power densities up to 550 mW.cm-2 and power of 2.2 kWnet per gram of platinum. The estimated costs showed that there was a reduction of up to 64.5 %, compared to the MEA structures previously known. Depending on the temperature and operating pressure, values from US$ 1,475.30 to prepare MEAs for each installed kilowatt were obtained. Taking into account recent studies, it was concluded that the cost of the developed MEA is compatible with PEMFC stationary application.
324

Desenvolvimento de novos sensores eletroquímicos descartáveis para fins analíticos / Development of new disposable electrochemical sensors for analytical purposes

Ana Paula Ruas de Souza 16 October 2015 (has links)
O presente trabalho trata do desenvolvimento de sensores eletroquímicos que possuam características descartáveis e ao uso destes dispositivos para a determinação de diferentes analitos em amostras biológicas, farmacêuticas e de interesse ambiental. O desenvolvimento e a aplicação dos sensores foram divididos em seis capítulos. O primeiro capítulo corresponde a fabricação de conjuntos de microeletrodos em suporte de CD-RW e placa fenolite utilizando impressão com tinta toner. Os conjuntos de microeletrodos foram fabricados por meio da deposição de duas máscaras de toner em um substrato de cobre ou ouro. Os eletrodos fabricados neste capítulo foram caracterizados e aplicados nos capítulos subsequentes. Os resultados da aplicação do conjunto de microeletrodos de cobre (DCRM) foram descritos no segundo capítulo. Os dispositivos foram aplicados para a determinação de peróxido de hidrogênio em amostras de antisséptico bucal e clareadores dentais. As determinações foram realizadas em solução de tampão fosfato (pH 7.0) por meio da técnica de amperometria (E = -0,2 V). Estes sensores foram também aplicados para determinação de ácido acetilsalítico (AAS) em amostras farmacêuticas em solução de hidróxido de sódio 0,1 mol L-1 por amperometria (E = 0,6 V). A determinação de nitrato em amostra de água de rio foi realizada por amperometria (E = -0,45V) em solução de sulfato de sódio 0,1 mol L-1 (pH = 2,0). Os resultados obtidos com o sensor demonstraram o sucesso das aplicações. As principais vantagens deste dispositivo dizem respeito à simplicidade de fabricação, baixo custo do equipamento e rapidez das análises. A caracterização eletroquímica do sensor e a determinação de ciclopirox olamina em solução de tampão BR 0,1 mol L-1 (pH = 5,0) utilizando o conjunto de microeletrodos de ouro (CD-RW) foi apresentada no terceiro capítulo. Os resultados obtidos mostraram que é possível realizar a determinação desta espécie de interesse em soluções oftalmológicas. O desenvolvimento, a caracterização e aplicação de um novo conjunto de microeletrodos de ouro fabricados a partir da redução eletroquímica da 5-bromo-1,10-fenantrolina em solução de dimetilformalmida (DMF) foi investidada no quarto capítulo. A superfície foi bloqueada com um filme isolante de 1,10-fenantrolina e o sensor foi caracterizado como um conjunto de microeletrodos de ouro. O sensor foi aplicado para a determinação de peróxido de hidrogênio, nas condições descritas anteriormente a fim de avaliar a aplicabilidade deste dispositivo. Os resultados obtidos foram promissores. A utilização de um eletrodo de microbanda impresso na configuração \"back-to-back\" foi descrita no quinto capítulo. A configuração faz uso da impressão de um novo eletrodo nas costas de um eletrodo impresso \"tradicional\", aumentando com isso a sensibilidade do sensor. O eletrodo impresso na configuração \"back-to-back\" foi utilizado para a determinação de íons Pb(II) em amostras de água potável por meio da técnica de voltametria de redissolução anódica por onda quadrada e os resultados obtidos foram concordantes com os encontrados utilizando espectrometria de emissão atômica por plasma acoplado. Os eletrodos de microbanda impressos na configuração \"back-to-back\" modificados com nanotubos de carbono para a determinação de capsaicina e dopamina e com ftalocianina de cobalto (II) para determinação de hidrazina foram investigados no sexto capítulo. Os resultados obtidos foram concordantes com aqueles descritos em outros trabalhos encontrados na literatura. / This work presents results on the fabrication of disposable electrochemical sensors and the use of such devices for the determination of different analytes in biological, pharmaceutical and environmental samples. The development and application of these sensors have been divided into six chapters. The first chapter describes the fabrication of a microelectrode ensemble (CD-RW) using ink toner. The sensor was fabricated by deposition of two toner pattern masks on copper and gold substrates. The electrodes fabricated according this procedure were characterized and applied in subsequent chapters. The second chapter describes the use of a disposable copper random microarrays (DCRM) for the amperometric determination of three analytes: hydrogen peroxide in real samples (oral antiseptic and dental whitening) at -0.2 V in phosphate buffer (pH 7.0) solution, acetylsalicylic acid (ASA) in pharmaceutical formulations at 0.6 V in 0.10 mol L-1 NaOH solution and nitrate in river samples at -0.45V in a 0.10 mol L-1 sodium sulfate solution (pH 2.0). The good results obtained with the DCRM demonstrated the successful application of this new sensor. The main advantages of the proposed manufacturing procedure are the simplicity, low cost of equipment and the high speed of production. The third chapter presents results on the use of a gold random microarray (GRM) for the determination of ciclopirox olamine in 0.10 mol L-1 Britton Robinson buffer solution (pH 5.0). Following the optimization of the experimental parameters, the proposed sensor presented excellent analytical properties for the amperometric detection of ciclopirox olamine at +0.85 V. The usefulness of the GRM sensor was confirmed by determining ciclopirox olamine in commercial products and the results obtained agreed well with those found by potentiometric titration and the labeled values. The fourth chapter describes the fabrication of a random assembly of microelectrodes (RAMs) by electrochemical reduction of 5-bromo-1,10- phenathroline in N,N-dimethylformamide (DMF), generating the 1,10-phenanthroline radical, which was covalently grafted on gold electrodes. After several potential cycles, the gold surface was partially blocked with an insulating film of 1,10-phenanthroline and the resulting modified electrode exhibited the characteristics of RAMs for the electrochemical reduction of the reversible probe 1,4-benzoquinone in DMF. This sensor was applied for hydrogen peroxide detection at -0.2 V in phosphate buffer (pH 7.0) solution. The fifth chapter reports on the use of screen-printed back-to-back microband electroanalytical sensors for quantification of lead(II) ions in drinking water samples in 0.01 mol L-1 HCl and the validation of the results by ICP-OES. The sixth chapter shows results on the use of back-to-back screen-printed microband electrodes modified with single-walled carbon nanotubes and cobalt phthalocyanine. The electroanalytical applications of this novel electrode configuration were exemplified towards the sensing of dopamine, capsaicin and hydrazine.
325

Estudo clínico randomizado para avaliação da segurança e dos efeitos da estimulação ventricular esquerda unifocal em pacientes com bradiarritmias / Randomized clinical trial for eficaccy, safety and performance of of isoleted left ventricular pacing in patients with bradyarrhythmias

Elizabeth Sartori Crevelari 31 August 2018 (has links)
Introdução: Considerando-se os potenciais efeitos deletérios da estimulação do ventrículo direito (VD), a hipótese desse estudo é que a estimulação unifocal ventricular esquerda (VE) pelo seio coronário é segura e pode proporcionar melhores benefícios clínicos e ecocardiográficos aos pacientes com bloqueio atrioventricular e função ventricular esquerda preservada ou pouco alterada, necessitando apenas da correção da frequência cardíaca. Objetivos: Avaliar a segurança, a eficácia e os efeitos da estimulação ventricular esquerda, utilizando um cabo-eletrodo com fixação ativa, em comparação à estimulação ventricular direita em pacientes com indicação de marca-passo (MP) convencional e função ventricular esquerda normal a moderadamente alterada. Métodos: Trata-se de um estudo clínico, randomizado, simples-cego que incluiu pacientes adultos com indicação de MP convencional por bloqueio atrioventricular avançado e função ventricular sistólica >= 0,40. A randomização aleatória (VD vs. VE) ocorreu antes do procedimento. Os desfechos primários do estudo foram o sucesso, a segurança e a eficácia do procedimento proposto. Os desfechos secundários foram a evolução clínica e alterações ecocardiográficas. Foram empregados os testes qui-quadrado, exato de Fisher e teste t de Student para comparação dos desfechos entre os dois grupos, considerando o nível de significância de 5%. Resultados: De junho de 2012 a janeiro de 2014 foram incluídos 91 pacientes, sendo 36 no grupo VD e 55 no grupo VE. As características basais dos pacientes dos dois grupos foram similares (P = NS). O implante de MP foi realizado com sucesso e sem nenhuma intercorrência em todos os pacientes do grupo VD. No grupo VE, entretanto, dos 55 pacientes inicialmente alocados, o implante do cabo-eletrodo em veias coronárias não foi possível em 20 (36,4%) pacientes. Complicações pós-operatórias foram detectadas apenas no grupo VE. A complicação mais frequente foi a estimulação frênica, detectada em 9 (25,7%) pacientes. Durante o período de seguimento do estudo, não houve hospitalizações por insuficiência cardíaca. Reduções superiores a 10% na fração de ejeção do ventrículo esquerdo foram observadas em 23,5% dos pacientes do grupo VD e em 20,6% dos do grupo VE (P = 0,767). A análise feita pelo Doppler tecidual mostrou que 55,9% dos indivíduos do grupo VD e 43,8% dos do grupo VE apresentaram dissincronia intraventricular ventricular esquerda (P = 0,324). Pelo mesmo método, foi detectado que 91,2% e 68,8% dos pacientes dos grupos VD e VE, respectivamente, apresentavam dissincronia interventricular (P=0,022). Conclusões: A estimulação ventricular esquerda exclusiva, nas condições estudadas, mostrou taxa de sucesso, segurança e eficácia inadequadas. A despeito da melhor sincronia interventricular observada nos pacientes sob estimulação ventricular esquerda, a comparação dos desfechos secundários entre os dois grupos não mostrou diferenças significativas / Background: Considering the potential deleterious effects of right ventricular (RV) pacing, the hypothesis of this study is that isolated left ventricular (LV) pacing through the coronary sinus is safe and may provide better clinical and echocardiographic benefits to patients with bradyarrhythmias and normal ventricular function requiring only the correction of heart rate. Objective: To assess the safety, efficacy and effects of LV pacing using an active-fixation coronary sinus lead compared to RV pacing in patients eligible to conventional pacemaker (PM) implantation. Methods: Randomized, controlled and single-blinded trial in adult patients submitted to PM implantation due to bradyarrhythmias and systolic ventricular function >= 0.40. Randomization (RV vs LV) occurred before PM implantation. Procedural success, safety, and efficacy were the main endpoints. Secondary outcomes were clinical and echocardiographic changes. Chi-square, Fisher\'s exact test and Student\'s t test were used, considering a significance level of 5%. Results: From June/2012 to January/2014, 91 patients were included, 36 in the RV group and 55 in the LV group. Baseline characteristics of patients in both groups were similar. PM implantation was performed successfully and without any complications in all patients in the RV group. Of the 55 patients initially allocated to the LV group, the implant of the active-fixation coronary sinus lead was not possible in 20 (36.4%) patients. The most frequent complication was phrenic nerve stimulation, detected in 9 (25.7%) patients in the LV group. During the follow-up period, there were no hospitalizations for heart failure. Reductions of more than 10% in left ventricular ejection fraction were observed in 23.5% of patients in the RV group and in 20.6% of those in the LV group (P= 0.767). Echo-tissue doppler showed that 91.2% of subjects in the RV group and 68.8% of those in the LV group had interventricular dyssynchrony (P= 0.022). Conclusion: Isolated left ventricular pacing, under the conditions studied, showed an inadequate success rate, safety and efficacy. Despite the better interventricular synchrony observed in LV group, the comparison of secondary outcomes between the two groups did not show significant differences
326

Estudo e desenvolvimento de conjuntos membrana-eletrodos (MEA) para célula a combustível de eletrólito polimérico condutor de prótons (PEMFC) com eletrocatalisadores à base de paládio / Study and development of membrane electrode assemblies for proton exchange membrane fuel cell (PEMFC) with palladium based catalysts

Rafael Nogueira Bonifacio 19 November 2013 (has links)
Sistemas de PEMFC são capazes de gerar energia elétrica com alta eficiência e baixa ou nenhuma emissão de poluentes, porém questões de custo e durabilidade impedem sua ampla comercialização. Nesse trabalho foi desenvolvido um MEA com eletrocatalisadores à base de paládio. Foram sintetizados e caracterizados eletrocatalisadores Pd/C, Pt/C e Ligas PdPt/C com diferentes razões entre metais e carbono. Foi realizado um estudo da razão entre ionômero de Nafion e eletrocatalisador para formação de triplas fases reacionais de máximos desempenhos, criado um modelo matemático para transpor esse ajuste para eletrocatalisadores com diferentes razões entre metal e suporte, considerando os aspectos volumétricos da camada catalisadora, e então realizado um estudo da espessura da camada catalisadora. Para as caracterizações foram utilizadas as técnicas de Difração de Raios-X, Microscopias Eletrônicas de Transmissão e de Varredura, Energia Dispersiva de Raios-X, Picnometria a Gás, Porosimetria por Intrusão de Mercúrio, Adsorção de Gás, segundo as equações de BET e BJH, Análise Termo Gravimétrica e feitas as determinações de diâmetros de partículas, de áreas de superfície específica e de parâmetros de rede. Todos os eletrocatalisadores foram usados no preparo de MEAs que foram avaliados em célula unitária de 5 cm2 entre 25 e 100 °C a 1 atm; e a melhor composição foi avaliada também a 3 atm. No estudo dos metais para as reações, visando reduzir a platina aplicada aos eletrodos, sem perdas de desempenho, foram selecionados Pd/C para ânodos e PdPt/C 1:1 para cátodos. A estrutura de MEA desenvolvida utilizou 0,25 mgPt.cm-2 e resultou em densidades de potência de até 550 mW.cm-2 e potências de até 2,2 kWe por grama de platina. A estimativa realizada mostrou que houve uma redução de até 64,5 % nos custos em relação à estrutura de MEA previamente conhecida. Em função da temperatura e pressão de operação foram obtidos valores a partir de R$ 3.540,73 para o preparo de MEAs para cada quilowatt instalado. Com base em estudos recentes, concluiu-se que o custo do MEA desenvolvido é compatível às aplicações estacionárias de PEMFC. / PEMFC systems are capable of generating electricity with high efficiency and low or no emissions, but durability and cost issues prevent its large commercialization. In this work MEA with palladium based catalysts were developed, Pd/C, Pt/C and alloys PdPt/C catalysts with different ratios between metals and carbon were synthesized and characterized. A study of the ratio between catalyst and Nafion Ionomer for formation of high performance triple-phase reaction was carried out, a mathematical model to implement this adjustment to catalysts with different relations between metal and support taking into account the volumetric aspects of the catalyst layer was developed and then a study of the catalyst layer thickness was performed. X-ray diffraction, Transmission and Scanning Electron Microscopy, X-ray Energy Dispersive, Gas Pycnometry, Mercury Intrusion Porosimetry, Gas adsorption according to the BET and BJH equations, and Thermo Gravimetric Analysis techniques were used for characterization and particle size, specific surface areas and lattice parameters determinations were also carried out. All catalysts were used on MEAs preparation and evaluated in 5 cm2 single cell from 25 to 100 °C at 1 atm and the best composition was also evaluated at 3 atm. In the study of metals for reactions, to reduce the platinum applied to the electrodes without performance losses, Pd/C and PdPt/C 1:1 were selected for anodes and cathodes, respectively. The developed MEA structure used 0,25 mgPt.cm-2, showing power densities up to 550 mW.cm-2 and power of 2.2 kWnet per gram of platinum. The estimated costs showed that there was a reduction of up to 64.5 %, compared to the MEA structures previously known. Depending on the temperature and operating pressure, values from US$ 1,475.30 to prepare MEAs for each installed kilowatt were obtained. Taking into account recent studies, it was concluded that the cost of the developed MEA is compatible with PEMFC stationary application.
327

Estudo experimental do escoamento bifásico ar-água em uma bomba centrífuga radial / Experimental study of two-phase flow air-water in a radial centrifugal pump

Cubas, Jhoan Miguel Cubas 05 July 2017 (has links)
PETROBRAS / Ao longo dos últimos anos a utilização de bombas centrífugas submersas (BCS) se tornou o segundo método de elevação artificial mais usado na indústria petrolífera. Como a produção típica dos poços petrolíferos submarinos consiste em misturas contendo óleo e gás, as bombas centrífugas estão sujeitas a operar com escoamento bifásico. A presença de gás livre no escoamento provoca instabilidades e degradação da curva de ganho de pressão da bomba. Essa degradação se torna muito grande quando ocorre o fenômeno de surging. Este fenômeno é caracterizado por um grande acúmulo de gás nos canais do rotor, sendo seu início identificado como um ponto na curva de ganho de pressão a partir do qual o desempenho cai de forma abrupta com a diminuição da vazão do líquido. Dependendo da fração de gás na entrada da bomba, pode ocorrer o bloqueio dos canais do rotor, fenômeno conhecido como gas locking, fazendo com que a vazão de líquido e o incremento de pressão sejam praticamente nulos. Portanto, é fundamental o conhecimento das condições operacionais e padrões de escoamento ligados à ocorrência de surging para uma operação adequada da bomba. Nesse cenário, o presente trabalho tem por objetivo avaliar o desempenho de uma bomba centrífuga operando com escoamento bifásico ar-água. Para esse fim, foram levantadas as curvas de ganho de pressão de uma bomba centrifuga convencional de dois estágios com rotores de tipo radial. Os testes foram feitos utilizando água e ar como fluidos de trabalho, com frações volumétricas de gás entre 0 e 10%, velocidades de rotação entre 300 e 600 rpm, com vazões de água entre 0,2 e 1,5 vezes o ponto de máxima eficiência e uma pressão de sucção de 160 kPa. Ao mesmo tempo, foram identificados os diferentes padrões de escoamento dentro do rotor em diferentes condições operacionais. Para construção da bancada, a carcaça da bomba e o rotor original de seu primeiro estágio foram substituídos por outros de material transparente, o que permitiu fotografar a distribuição de gás na bomba com a ajuda de uma câmera de alta velocidade. Além de se utilizar o modelo homogêneo (não deslizamento) como referência para calcular a fração de vazio de entrada em cada teste, um sensor de malha de eletrodos (wire mesh) foi instalado na sucção da bomba com o objetivo de medir frações de vazio reais, que posteriormente foram comparadas com os resultados do modelo homogêneo e o de deslizamento (drift flux). As imagens obtidas foram associadas às instabilidades observadas nas curvas de desempenho da bomba, como forma de se compreender os fenômenos relacionados à queda de desempenho em operação com escoamento bifásico, em especial nas condições de surging. Esse procedimento, associado à medida da fração de vazio real na entrada da bomba, não apenas contribui com o entendimento do escoamento bifásico líquido-gás em bombas, como também oferece uma fonte interessante de dados de entrada e de validação de modelos teóricos e numéricos para outros trabalhos. / Over the last years the use of electric submersible centrifugal pumps (ESPs) has become the second most widely used artificial elevation method in the oil industry. As the typical production of submarine oil wells consists of mixtures containing oil and gas, the centrifugal pumps are subjected to operate with two-phase flow. The presence of free gas in the flow causes instabilities and degradation of the pump pressure-rise curve. This degradation becomes severe when the surging phenomenon occurs, which is characterized by large gas accumulations inside the impeller, with its initiation identified as the point in the pressure-rise curve from which the performance falls abruptly with the decrease of the liquid flow rate. Depending on the intake gas fraction, the rotor channels can be completely blocked (gas locking), causing the liquid flow rate and the pressure-rise to be almost null. Therefore, knowledge of operating conditions and flow patterns linked to the occurrence of surging for proper pump operation is critical. In this scenario, the present work aims to evaluate the performance of a centrifugal pump operating with two-phase air-water flow. To this end, the pressure-rise curves of a conventional two-stage centrifugal pump with radial rotors were measured. The tests were done using water and air as working fluids, with volumetric gas fractions between 0 and 10%, rotational speeds between 300 and 600 rpm, water flow rates between 0.2 and 1.5 times the best efficiency point and a suction pressure of 160 kPa. At the same time, different flow patterns were identified inside the rotor under different operating conditions. For this purpose, the pump casing and the original rotor of its first stage were replaced by equivalent transparent pieces, which allowed photographing the gas distribution inside the pump with the help of a high-speed camera. In addition to using the homogeneous (non-slip) model as a reference to calculate the inlet gas volume fraction in each test, a wire mesh sensor was installed in the intake pipe in order to measure the actual void fractions, which were later compared with the results from the homogeneous and the drift flux models. The images obtained were associated with the instabilities observed in the performance curves of the pump, as a way to understand the phenomena related to the performance degradation in two-phase flow operation, especially under surging conditions. This procedure, together with the measurement of the actual gas volume fractions in the pump intake, not just contributes to the understanding of gas-liquid flows in pumps, but also provides an interesting source of data for input and validation of theoretical and numerical models for other investigations.
328

Determinação voltamétrica de triclocarban e carbendazim em produtos de higiene pessoal e água potável

Lúcio, Maria Mônica Lacerda Martins 26 August 2015 (has links)
Submitted by Maike Costa (maiksebas@gmail.com) on 2016-05-11T12:53:38Z No. of bitstreams: 1 arquivo total.pdf: 6105657 bytes, checksum: 8404a0fcb54e3893c95fdfb017f0ac96 (MD5) / Made available in DSpace on 2016-05-11T12:53:38Z (GMT). No. of bitstreams: 1 arquivo total.pdf: 6105657 bytes, checksum: 8404a0fcb54e3893c95fdfb017f0ac96 (MD5) Previous issue date: 2015-08-26 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPq / Triclocarban (TCC) is a bactericide and fungicide widely used in personal care products, while carbendazim (MBC) is a fungicide widely used in cereal crops and a variety of fruits and vegetables, both are considered environmental contaminants. In this paper, propose the study of oxidation and determination of TCC using glassy carbon electrode (ECV) and the use of a carbon paste electrode modified with carbon nanotubes functionalized multi walled (EPC-NTCPMF) to determine MBC. Electrochemical detection of TCC and MBC was studied using different voltammetric techniques on a wide range of pH and the determination was performed on samples of soaps, only the TCC and drinking water at low concentrations, for both contaminants. For TCC, various oxidation processes were observed, however the peak P1 had greater sensitivity and selectivity in acetate buffer, pH 5.4 and was therefore used for the development of voltammetric methods, direct VOQ and adsorptive stripping voltammetry. For adsorptive stripping voltammetry, the linear response range was from 1.8 to 21 × 10-9 mol L-1 with a detection limit (LD) of 3.2 × 10-10 mol L-1, 1,000 times smaller than the LD obtained by direct VOQ. The method of adsorptive stripping voltammetry showed satisfactory levels of repeatability, 4.1% and reproducibility, 5.4% and was applied to determine TCC in soaps samples and an average recovery of 95.3% and drinking water with an average recovery apparent 95.4%. The MBC peaked main oxidation, almost reversible; the better sensitivity was achieved in H2SO4, pH 1.0 on the EPC-NTCPMF using VOQ. The linear response range is between 3 and 150 × 10-10 mol L-1 to LD 1.1 × 10-11 mol L-1. The method developed showed acceptable levels of repeatability, 4.6% and reproducibility, 6.2% and was applied for MBC determination in drinking water samples obtained average apparent recovery of 95.6%. The results obtained in the development of methods for determination of TCC and MBC showed excellent applicability for the studied samples, in addition to having advantages such as low cost instrumentation, analytical fast response, high sensitivity and selectivity. / Triclocarban (TCC) é um bactericida e fungicida amplamente utilizado em produtos de higiene pessoal, enquanto que o carbendazim (MBC) é um fungicida muito utilizado em culturas de cereais e numa grande variedade de frutas e vegetais, e ambos são considerados contaminantes ambientais. Nesse trabalho, propõe-se o estudo da oxidação e determinação do TCC utilizando eletrodo de carbono vítreo (ECV) e o uso de um eletrodo de pasta de carbono modificado com nanotubos de carbono de múltiplas paredes funcionalizado (EPC-NTCPMF) para determinação de MBC. A detecção eletroquímica de TCC e MBC foi estudada utilizando diferentes técnicas voltamétricas sobre uma ampla faixa de pH e a determinação foi realizada em amostras de sabonetes para TCC e em água potável em baixas concentrações para os dois contaminantes. Para TCC, foram observados seis processos de oxidação, entretanto, o processo correspondente ao pico P1 apresentou maior sensibilidade e seletividade em tampão acetato pH 5,4, portanto, foi utilizado para o desenvolvimento das metodologias voltamétricas, VOQ direta e VOQ com redissolução adsortiva. Para a VOQ com redissolução adsortiva, a faixa de resposta linear foi de 1,8 a 21 × 10-9 mol L-1 com limite de detecção (LD) de 3,2 × 10-10 mol L-1, 1.000 vezes menor do que o LD obtido por VOQ direta. O método de redissolução adsortiva apresentou níveis satisfatórios de repetibilidade, 4,1% e reprodutibilidade, 5,4% e foi aplicado para determinação de TCC em amostras de sabonetes, obtendo uma recuperação média de 95,3% e água potável com uma média de recuperação aparente de 95,4%. O MBC apresentou um pico de oxidação principal, quase reversível e a maior sensibilidade foi alcançada em H2SO4, pH 1,0, sobre o EPC-NTCPMF, utilizando VOQ. A faixa de resposta linear está entre 3 e 150 × 10-10 mol L-1 com LD de 1,1 × 10-11 mol L-1. O método desenvolvido apresentou níveis satisfatórios de repetibilidade, 4,6% e reprodutibilidade, 6,2% e foi aplicado para determinação de MBC em amostras de água potável, obtendo-se valor médio de recuperação aparente de 95,6%. Os resultados obtidos no desenvolvimento dos métodos para determinação de TCC e MBC demonstraram excelente aplicabilidade para as amostras estudadas, além de apresentarem vantagens como instrumentação de baixo custo, rápida resposta analítica, elevada sensibilidade e seletividade.
329

Ambiente para aquisição e processamento de sinal eletromiográfico de superfície / Environment to acquisition and processing of surface electromyography signal

Magagnin Junior, Ari 22 December 2015 (has links)
Nesse trabalho foi desenvolvida uma plataforma para o condicionamento, digitalização, visualização e gravação de sinais de eletromiografia (EMG). Posteriormente a aquisição, a análise pode ser realizada através de técnicas de processamento de sinais. A plataforma consiste em dois módulos que adquirem sinais de EMG através de eletrodos de superfície, limitam a faixa de frequências de interesse, filtram interferências da rede elétrica e digitalizam os sinais pelo conversor analógico-digital do microcontrolador dos módulos. Deste modo, os dados são enviados para o computador pela interface USB na especificação HID, sendo apresentados em tempo real na forma gráfica e armazenados em arquivo. Como recursos de processamento foram implementadas as operações de módulo do sinal, a determinação do valor eficaz (RMS), a análise de Fourier, filtro digital (IIR) e filtro adaptativo. Foram realizados testes iniciais de avaliação da plataforma com sinais de membros inferiores e superiores para fins de comparação de lateralidade de sinais de EMG. A plataforma aberta destina-se a atividades didáticas e a pesquisa acadêmica, permitindo acrescentar outros métodos de processamento que o pesquisador tenha interesse em avaliar ou outras análises que se façam necessárias. / In this work, a platform to the conditioning, digitizing, visualization and recording of the EMG signals was developed. After the acquisition, the analysis can be done by signal processing techniques. The platform consists of two modules witch acquire electromyography (EMG) signals by surface electrodes, limit the interest frequency band, filter the power grid interference and digitalize the signals by the analogue-to- digital converter of the modules microcontroller. Thereby, the data are sent to the computer by the USB interface by the HID specification, displayed in real-time in graphical form and stored in files. As processing resources was implemented the operations of signal absolute value, the determination of effective value (RMS), Fourier analysis, digital filter (IIR) and the adaptive filter. Platform initial tests were performed with signal of lower and upper limbs with the aim to compare the EMG signal laterality. The open platform is intended to educational activities and academic research, allowing the addition of other processing methods that the researcher want to evaluate or other required analysis.
330

Sensor wire-mesh de impedância para investigação de escoamentos multifásicos

Vendruscolo, Tiago Piovesan 03 July 2012 (has links)
BG - Brasil e do Instituto Brasileiro de Petróleo, Gás e Biocombustíveis / Escoamentos multifásicos estão presentes em diversas atividades industriais como na exploração, produção e transporte de petróleo e gás, onde é comum encontrar escoando por dutos uma mistura de óleo, gás e água. Em muitos casos, o tipo de escoamento determina a eficiência e segurança dos processos e equipamentos onde ocorrem. Com isso, investigações experimentais de escoamento multifásicos são de grande importância no auxilio do desenvolvimento de modelos teóricos e na validação de predições realizadas por simulações, ampliando o entendimento do fenômeno. No passado algumas técnicas para investigação de escoamentos multifásicos foram propostas e aplicadas. Contudo, estas técnicas, na sua maioria, estão limitadas a investigação de escoamentos envolvendo apenas duas fases. Neste trabalho, foi proposta uma nova eletrônica para operar um sensor de malha de eletrodos (Wire-Mesh Sensor) que é capaz de investigar escoamentos contendo até três fases. Inicialmente proposto para visualização de escoamentos bifásicos, o sensor wire-mesh realiza o imageamento da distribuição de fases de uma seção transversal. Com a passagem do escoamento através do sensor, o mapeamento das fases é realizado de forma intrusiva com alta resolução temporal e espacial. Para possibilitar seu uso em escoamentos trifásicos, neste trabalho foi desenvolvida uma nova eletrônica capaz de medir simultaneamente a permissividade elétrica e a condutividade elétrica do fluido presente entre os eletrodos do sensor. O princípio básico do funcionamento é baseado na excitação com duas frequências distintas. Além do hardware foi também desenvolvido um software, onde é possível salvar os dados adquiridos em uma base de dados para futuros estudos. O desempenho da nova eletrônica foi verificado através de medições em componentes (rede RC) com valores de referência. O sistema completo foi utilizado para gerar imagens de uma mistura trifásica ar-óleo-água em condições estáticas e dinâmicas, apresentando bons resultados. Desta forma, a principal contribuição deste trabalho é a disponibilização de uma nova ferramenta para análise de escoamentos multifásicos. / Multiphase flows are present in many industrial activities such as in exploration, production and transportation of oil and gas, in which is common to find a mixture of oil, gas and water flowing inside pipes. In many cases this type of flow determines the efficiency and safety of the processes and equipment where they occur. In this way, experimental investigations of multiphase flow are of great value to develop new theoretical models and to validate predictions made by computer simulations, hence increasing the understanding of the flow phenomena. In this work, a new measuring electronics to operate a wire-mesh sensor (WMS) is introduced. Initially proposed for visualization of two-phase flow, the WMS performs the imaging of the phase distribution of a cross section based on the multiplexed measurement of an electrical property of the fluid in contact with the mesh grid of the sensor. With the passage of flow through the sensor, the phase mapping is realized by intrusive electrodes at high temporal and spatial resolution. To allow its use in multiphase flows, the new electronics developed in this work simultaneously measures the electrical permittivity and electrical conductivity of the media in the mesh grid. The basic idea is to activate the electrodes with a signal composed of two distinct frequencies. Besides the development of the electronics' hardware, a software was also implemented, by which data can be acquired and for future investigation. The performance of the new instrument has been verified by use of components (RC network) with reference values. The developed system was used to generate images of a multiphase mixture of air-oil-water in static and dynamic conditions, showing good results. Thus, the main contribution of this work is to make available a new tool for the investigation of multiphase flows.

Page generated in 0.0789 seconds