• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 41
  • 15
  • 2
  • Tagged with
  • 55
  • 22
  • 18
  • 16
  • 12
  • 12
  • 10
  • 6
  • 6
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Étude transversale sur l’asepsie des articles transférés entre la clinique et le laboratoire dentaire et de l’instrumentation de laboratoire

Bezerianos, Joanna 09 1900 (has links)
Les mesures de contrôle de la contamination croisée sont principalement concentrées dans la salle opératoire dentaire alors que les articles transférés entre la clinique et le laboratoire dentaire et les instruments de laboratoire ont reçu peu d’attention. Cette étude vise à documenter l’application des mesures d’asepsie sur ces articles par les professionnels du domaine dentaire ainsi que leurs perceptions entourant ces mesures. Un questionnaire autoadministré et anonyme a été envoyé à un échantillon aléatoire des dentistes, denturologistes et directeurs de laboratoire dentaire qui étaient inscrits aux listes des ordres professionnels en juin 2008 dans la province de Québec. Des 1100 questionnaires envoyés, 376 ont été retournés remplis. Presque trois quarts (72,1 %) des répondants affirment faire l’asepsie des instruments de laboratoire et 74,9 %, la désinfection des articles transférés mais avec des pourcentages variables selon le groupe d’articles (empreintes, prothèses, etc.). Seulement 9,1 % de professionnels identifient de façon générale les articles désinfectés avant l’envoi. Plus de la moitié des professionnels (51,4 %) trouvent qu’ils n’ont pas assez d’information sur l’asepsie des articles transférés et 62,4 %, qu’elle est difficile à appliquer. Cette étude est la première réalisée auprès des trois groupes de professionnels et la première à étudier leurs perceptions entourant l’asepsie des articles transférés et de l’instrumentation de laboratoire. Nous avons démontré que l’application des mesures d’asepsie à ces articles par les professionnels du domaine dentaire n’est pas toujours conforme aux normes proposées et qu’il existe un besoin de renforcer leur application, surtout en ce qui a trait aux articles transférés. / Infection control practices have been mainly concentrated in the dental operatory whereas the articles transferred between the dental clinic and the dental laboratory as well as laboratory instruments have received less attention. This study attempts to document the practices of dental care professional implicated in the fabrication of dental prosthesis as to the asepsis of these items as well as their perceptions towards it. In June 2008 an auto-administrated and anonymous questionnaire was sent to a random sample of dentists, denturologists and dental laboratory directors licensed to practice in the province of Quebec (Canada). From the 1,100 questionnaires sent, 376 were returned filled-in. Almost two thirds of responders (72.1%) claim to disinfect or sterilize laboratory instruments and 74.9% to disinfect transferred articles, with percentages varying according to the group of articles (impressions, prosthesis, etc.). However, only 9.1% regularly identify disinfected work. More than half of the responders (51.4%) think it is difficult to apply a form of asepsis on transferred articles and 62.4% believe there is a lack of information towards it. This study is the first to have been addressed simultaneously to the three groups of professionals and the first to question them on their perceptions. It demonstrated that the application of asepsis measures to transferred articles and laboratory instruments by dental care professionals is not always complying with existing recommendations. There is a need to reinforce their application, especially of asepsis measures on transferred articles.
32

Transports et désenclavement dans la problématique du développement local à Téra au Niger

Abdou Yonlihinza, Issa 05 December 2011 (has links) (PDF)
Les difficultés dans la mobilité des personnes et des biens constituent l'un des obstacles majeurs à l'amélioration des conditions de vie des populations des pays sous-développés en général et celles de l'Afrique en particulier. Cette situation est particulièrement vraie pour la république du Niger. En observant la carte de l'Afrique on peut déjà imaginer les contraintes que peuvent induire la position géographique du pays pour ses échanges avec l'extérieur. Aussi, autant son isolement externe est criant, autant à l'intérieur du territoire national, l'enclavement est réel et pose un véritable problème de développement. L'étendue du territoire, son enclavement et une situation de fragilité économique constituent les éléments fondamentaux du contexte dans lequel évolue le secteur des transports au Niger. À l'échelle du territoire nigérien, le département de Téra permet d'appréhender les difficultés que pose le dysfonctionnement d'un système de transport et de voir comment la mobilité s'inscrit dans le processus du développement local. La faiblesse de l'offre des services de transport, la vétusté des infrastructures et le difficile accès aux moyens de transport sont des problèmes récurrents pour les populations. Les stratégies des acteurs n'ont eu qu'un impact limité sur l'amélioration de la mobilité dans l'espace départemental. Cet important dysfonctionnement dans la mobilité des personnes et des biens devra être résolu.
33

Development of molecularly imprinted polymers for the recognition of urinary nucleoside cancer biomarkers / Développement de polymères à empreintes moléculaires pour la reconnaissance de biomarqueurs nucléosidiques urinaires du cancer

Krstulja, Aleksandra 27 February 2015 (has links)
Ce rapport de thèse présente l’étude de la technologie des empreintes moléculaires pour le développement de polymères spécifiques et sélectifs envers des biomarqueurs urinaires nucléosidiques du cancer colorectal chez l’Homme. L’objectif principal était de développer des polymères à empreintes moléculaires compatibles aux milieux aqueux en utilisant la technique du « dummy template », l’approche non-covalente and la polymérisation radicalaire en masse. Nous nous sommes concentrés principalement sur la qualité des polymères à partir de leur formulation, c’est-à-dire la spécificité et la sélectivité. Cela a été mené de façon empirique d’abord par la production de poudres issues de polymères monolithiques. Ainsi, pour atteindre les objectifs fixés, nous avons exploré le choix de la molécule « template ». Une étude de modèle est présentée au chapitre 3, en utilisant trois nucléosides 2’,3’,5’-peracétylés comme molécule empreinte dans une approche « dummy template ». Ensuite, en s’appuyant sur la connaissance apportée par le chapitre 3, nous avons développé des polymères à empreintes moléculaires (MIPs) sélectifs de la pseudouridine et de la N7-méthylguanosine dans les chapitres 4 et 5, respectivement, en utilisant la 2’,3’,5’-tri-O-acétylpseudouridine et la 2’,3’,5’-tri-O-acétylguanosine comme templates. L’étude de la rétention des nucléosides recherchés et de leurs analogues structuraux menée par chromatographie en phase liquide et par analyse frontale a permis de déterminer la capacité des différents polymères et de connaître leur comportement dans de l’urine synthétique. Finalement, pour évaluer la possible application de ces polymères dans un échantillon réel, l’urine humaine, la technique de l’extraction sur phase solide à empreintes moléculaires ou MISPE a été développée. Ainsi, une purification sélective des biomarqueurs cibles, tels que la pseudouridine et la N7-méthylguanosine, dans des échantillons d’urines a pu être démontrée. / This thesis report presents the exploration of molecularly imprinted polymer (MIP) technology for developing of a sensitive and selective polymers used in urinary nucleoside biomarker recognition. The main goal was to develop water compatible MIPs prepared by a “dummy template” imprinting technology, using a non-covalent approach and radical-polymerization in bulk. We were focusing mostly on the polymer quality in the formulation (rigidity, stability and repeatability). This was chosen empirically first by production of powders from monolithic MIP. Thus, to accomplish the stated goals, we have explored the choice of the template molecule. A model study presented by Chapter 3, using three 2’3’5’-tri-Operacylateduridine nucleosides as templates in a “dummy” template approach was first developed. Then, applying the knowledge of the type of template choice, we developed a selective MIP for recognition of pseudouridine and N7-methylguanosine in the studies presented in Chapter 4 and Chapter 5 respectively. By using 2’3’5’-tri-O-acetylpseudouridine and 2’3’5’-tri-O-acetylguanosine as templates. Chromatographic methods like HPLC retention and frontal analysis were used in the interest of determining the binding capacity of synthesized polymers, and the behavior in synthetic urine. Finally, to evaluate the possible application of these polymers in urine, molecularly imprinted solid phase extraction (MISPE) was developed. Selective purification of urine samples containing pseudouridine and N7-methylguanosine obtained in the end.
34

Smartphone-based indoor positioning using Wi-Fi, inertial sensors and Bluetooth / Positionnement intérieur basé sur les smartphones à l'aide de Wi-Fi, des capteurs inertiels et Bluetooth

Ta, Viet-Cuong 15 December 2017 (has links)
Grâce à l’émergence dans la vie quotidienne des appareils de plus en plus populaires que sont les smartphones et les tablettes, la tâche de postionner l'utilisateur par le biais de son téléphone est une problématique fortement étudiée dans les domaines non seulement de la recherche mais également des communautés industrielles. Parmi ces technologies, les approches GPS sont devenues une norme et ont beaucoup de succès pour une localisation en environnement extérieur. Par contre, le Wi-Fi, les capteurs inertiels et le Bluetooth sont plutôt préférés pour les tâches de positionnement dans un environnement intérieur.Pour ce qui concerne le positionnement des smartphones, les approches basées sur les « empreintes digitales » (fingerprint) Wi-Fi sont bien établies. D'une manière générale, ces approches tentent d'apprendre la fonction de correspondance (cartographie) des caractéristiques du signal Wi-Fi par rapport à la position de l’appareil dans le monde réel. Elles nécessitent généralement une grande quantité de données pour obtenir une bonne cartographie. Lorsque ces données d'entraînement disponibles sont limitées, l'approche basée sur les empreintes digitales montre alors des taux d’erreurs élevés et devient moins stable. Dans nos travaux, nous explorons d’autres approches, différentes, pour faire face à cette problématique du manque de données d'entraînement. Toutes ces méthodes sont testées sur un ensemble de données public qui est utilisé lors d’une compétition internationale à la Conférence IPIN 2016.En plus du système de positionnement basé sur la technologie Wi-Fi, les capteurs inertiels du smartphone sont également utiles pour la tâche de suivi. Les trois types de capteurs, qui sont les accéléromètres, le gyroscope et la boussole magnétique, peuvent être utilisés pour suivre l'étape et la direction de l'utilisateur (méthode SHS). Le nombre d'étapes et la distance de déplacement de l'utilisateur sont calculés en utilisant les données de l'accéléromètre. La position de l'utilisateur est calculée par trois types de données avec trois méthodes comprenant la matrice de rotation, le filtre complémentaire et le filtre de Madgwick. Il est raisonnable de combiner les sorties SHS avec les sorties de Wi-Fi, car les deux technologies sont présentes dans les smartphones et se complètent. Deux approches combinées sont testées. La première approche consiste à utiliser directement les sorties Wi-Fi comme points de pivot pour la fixation de la partie de suivi SHS. Dans la deuxième approche, nous comptons sur le signal Wi-Fi pour construire un modèle d'observation, qui est ensuite intégré à l'étape d'approximation du filtre à particules. Ces combinaisons montrent une amélioration significative par rapport au suivi SHS ou au suivi Wi-Fi uniquement.Dans un contexte multiutilisateur, la technologie Bluetooth du smartphone pourrait fournir une distance approximative entre les utilisateurs. La distance relative est calculée à partir du processus de numérisation du périphérique Bluetooth. Elle est ensuite utilisée pour améliorer la sortie des modèles de positionnement Wi-Fi. Nous étudions deux méthodes. La première vise à créer une fonction d'erreur qui permet de modéliser le bruit dans la sortie Wi-Fi et la distance approximative produite par le Bluetooth pour chaque intervalle de temps spécifié. La seconde méthode considère par contre cette relation temporelle et la contrainte de mouvement lorsque l'utilisateur se déplace. Le modèle d'observation du filtre à particules est une combinaison entre les données Wi-Fi et les données Bluetooth. Les deux approches sont testées en fonction de données réelles, qui incluent jusqu'à quatre utilisateurs différents qui se déplacent dans un bureau. Alors que la première approche n'est applicable que dans certains scénarios spécifiques, la deuxième approche montre une amélioration significative par rapport aux résultats de position basés uniquement sur le modèle d'empreintes digitales Wi-Fi. / With the popularity of smartphones and tablets in daily life, the task of finding user’s position through their phone gains much attention from both the research and industry communities. Technologies integrated in smartphones such as GPS, Wi-Fi, Bluetooth and camera are all capable for building a positioning system. Among those technologies, GPS has approaches have become a standard and achieved much success for the outdoor environment. Meanwhile, Wi-Fi, inertial sensors and Bluetooth are more preferred for positioning task in indoor environment.For smartphone positioning, Wi-Fi fingerprinting based approaches are well established within the field. Generally speaking, the approaches attempt to learn the mapping function from Wi-Fi signal characteristics to the real world position. They usually require a good amount of data for finding a good mapping. When the available training data is limited, the fingerprinting-based approach has high errors and becomes less stable. In our works, we want to explore different approaches of Wi-Fi fingerprinting methods for dealing with a lacking in training data. Based on the performance of the individual approaches, several ensemble strategies are proposed to improve the overall positioning performance. All the proposed methods are tested against a published dataset, which is used as the competition data of the IPIN 2016 Conference with offsite track (track 3).Besides the positioning system based on Wi-Fi technology, the smartphone’s inertial sensors are also useful for the tracking task. The three types of sensors, which are accelerate, gyroscope and magnetic, can be employed to create a Step-And-Heading (SHS) system. Several methods are tested in our approaches. The number of steps and user’s moving distance are calculated from the accelerometer data. The user’s heading is calculated from the three types of data with three methods, including rotation matrix, Complimentary Filter and Madgwick Filter. It is reasonable to combine SHS outputs with the outputs from Wi-Fi due to both technologies are present in the smartphone. Two combination approaches are tested. The first approach is to use directly the Wi-Fi outputs as pivot points for fixing the SHS tracking part. In the second approach, we rely on the Wi-Fi signal to build an observation model, which is then integrated into the particle filter approximation step. The combining paths have a significant improvement from the SHS tracking only and the Wi-Fi only. Although, SHS tracking with Wi-Fi fingerprinting improvement achieves promising results, it has a number of limitations such as requiring additional sensors calibration efforts and restriction on smartphone handling positions.In the context of multiple users, Bluetooth technology on the smartphone could provide the approximated distance between users. The relative distance is calculated from the Bluetooth inquiry process. It is then used to improve the output from Wi-Fi positioning models. We study two different combination methods. The first method aims to build an error function which is possible to model the noise in the Wi-Fi output and Bluetooth approximated distance for each specific time interval. It ignores the temporal relationship between successive Wi-Fi outputs. Position adjustments are then computed by minimizing the error function. The second method considers the temporal relationship and the movement constraint when the user moves around the area. The tracking step are carried out by using particle filter. The observation model of the particle filter are a combination between the Wi-Fi data and Bluetooth data. Both approaches are tested against real data, which include up to four different users moving in an office environment. While the first approach is only applicable in some specific scenarios, the second approach has a significant improvement from the position output based on Wi-Fi fingerprinting model only.
35

Conception et réalisation de capteurs biomimétiques à base de polymères à empreintes moléculaires à transduction électrochimique / Design and implementation of biomimetic electrochemical sensors transduction based on molecularly imprinted polymers

Betatache, Amina 13 December 2013 (has links)
Les biocapteurs sont des moyens d'analyse en plein essor à la fois rapides, sélectifs et peu coûteux, applicables à des domaines très variés (environnement, santé, agroalimentaire…). La capacité de reconnaissance moléculaire extraordinaire de biomolécules telles que les enzymes ou les anticorps a été exploitée avec succès pour la réalisation de nombreux biocapteurs. Cependant, l'inconvénient majeur de ces récepteurs biologiques est qu'ils sont difficiles à produire et fragiles. Une manière de surmonter ces inconvénients consiste à les remplacer par des récepteurs artificiels présentant des propriétés de reconnaissance similaires. Parmi les matériaux biomimétiques prometteurs figurent les polymères à empreintes moléculaires (MIPs). Dans ce travail, nous nous sommes intéressés au développement de deux capteurs biomimétiques impédimétriques, le premier basé sur l'utilisation de poly(éthylène co-alcool vinylique) imprimé pour la détection de la créatinine et le deuxième sur des MIPs de polyméthacrylate pour la détection de la testostérone. Dans le premier cas, le polymère imprimé a été produit et déposé à la surface d'électrodes en or, soit par drop-coating, soit sous forme de nanofibres par la technique d'électrofilage. Dans le deuxième, le MIP a été synthétisé par polymérisation radicalaire de l'acide méthacrylique en présence d'éthylèneglycol diméthacrylate (réticulant), d'initiateur et de testostérone en utilisant la méthode du « grafting from » qui consiste à greffer d'abord l'initiateur sur la surface du transducteur mais pour la polymérisation on a utilisé deux approches (spin-coating d'une solution de prépolymérisation sur la surface du transducteur ou l'immersion de ce dernier dans la solution de monomère plus testostérone) suivie de l'exposition à une source d'energie pour effectuer la polymérisation. Les performances des capteurs (limite de détection, sélectivité, reproductibilité) ont ensuite été évaluées / Biosensors are rapid, selective and low-cost analytical devices of growing interest for a wide range of application fields (e.g. environment, food, health). The extraordinary molecular recognition capabilities of sensing biomolecules such as enzymes and antibodies have been successfully exploited in the elaboration of a number of biosensors. However, these biorecognition elements are often produced via complex and costful protocols and require specific handling conditions because of their poor stability. To circumvent these limitations, artificial receptors of similar recognition properties are now proposed as alternatives to natural receptors in sensor technology. Molecular imprinted polymers are among the most promising biomimetic materials reported. In this work, we developed two impedimetric biomimetic sensors. The first one is based on imprinted poly(ethylene co-vinyl alcohol) for creatinine detection and the second on polymethacrylate MIPs for testosterone analysis. In the first case, MIP was produced and deposited onto gold microelectrodes, either by spin-coating of a pre-polymerization solution, or by electrospinning. In the second case, MIPs were synthetized by photopolymerization of methacrylic acid in presence of ethyleneglycoldimethacrylate (cross-linker), an azo-initiator and testosterone as template using the “grafting from” method in which the initiator is first attached to the transducer surface but to effect polymerization we used two different approaches (dip-coating of a prepolymerization solution on the transducer surface functionalized with the initiator or immersing it in the solution of monomers and testosterone) followed by exposure to an energy source to effect polymerization. Then, analytical performances (linear range, detection limit, selectivity and reproducibility) of both creatinine and testosterone sensors were determined and compared
36

Mise au point d'un microsystème électrophorétique pour l'analyse des hydrocarbures aromatiques polycycliques dans les huiles alimentaires / Development of a capillary electrophoresis microchip for polycyclic aromatic hydrocarbons analysis in edible oils

Ferey, Ludivine 31 October 2013 (has links)
Les hydrocarbures aromatiques polycycliques (HAP) sont des contaminants de notre environnement et de notre alimentation. En raison de leur toxicité, la Commission européenne a réglementé leur teneur dans les denrées alimentaires et notamment dans les huiles. Les industriels des corps gras ont donc pour obligation de vérifier la conformité de leurs produits. Dans ce contexte, le groupe Lesieur souhaiterait développer un nouvel outil analytique rapide et portable. Ainsi, ce vaste projet de recherche vise à concevoir un microsystème électrophorétique capable d'analyser les HAP dans les huiles alimentaires. Première étude à s'inscrire dans ce projet, ce travail de thèse a donc consisté à développer de nouveaux protocoles analytiques. Dans une première partie, des méthodes de séparation des HAP ont été développées en électrophorèse capillaire (CE) modifiée par des cyclodextrines couplée à un détecteur de fluorescence induite par laser. En suivant des stratégies multivariées basées sur les plans d'expériences, deux méthodes de séparation ont été optimisées. Les huit HAP communs aux listes établies par l'agence de protection de l'environnement des Etats-Unis et l'agence européenne de sécurité sanitaire des aliments ont été séparés en moins de 7 min et dix-neuf HAP, également classés par ces deux organismes, ont été analysés en moins de 18 min. Ces méthodes de séparation ont été appliquées avec succès à des extraits d'huile dopés. Dans une deuxième partie, il a été question de transférer la méthode d'analyse des huit HAP au format microsystèmes. La principale difficulté rencontrée a été le manque de sensibilité du système de détection couplé aux puces. Le premier objectif a donc été d'optimiser les quantités d'échantillon injectées et les paramètres de la détection avec un composé modèle dans un tampon borate. Cependant, seulement quatre HAP sur les dix-neuf étudiés précédemment en CE ont pu être détectés. Toutefois, dans les conditions optimisées par le plan d'expériences, ils étaient séparés en moins de 4 min. Enfin, différents polymères à empreintes moléculaires (MIP) ont été synthétisés en vue d'extraire sélectivement les HAP des huiles. Après un criblage des conditions de synthèse, la sélectivité de chaque MIP a été évaluée en milieu pur en comparant sa capacité de rétention avec celle d'un polymère non-imprimé. Les huit HAP communs aux deux listes ont finalement pu être extraits sélectivement à partir d'huiles de tournesol, mais avec des rendements d'extraction encore insuffisants et qui nécessitent une amélioration de la procédure d'extraction. / Polycyclic aromatic hydrocarbons (PAHs) are widespread contaminants in the environment and food products. Given their toxicity, their concentrations are regulated by the European Commission in food products and especially in edible oils. Consequently, manufacturers of fat products have to verify the conformity of their products. In this context, Lesieur wants to develop a rapid and portable new analytical tool. Hence, this ambitious research project aims at developing a capillary electrophoresis microchip for PAH analysis in edible oils. This PhD study, first one involved in this project, consisted in developing new analytical protocols.In a first part, PAH separation methods were developed by cyclodextrin-modified capillary electrophoresis (CE) with laser-induced fluorescence detection. Using experimental design-based strategies, two separation methods were optimized. The 8 PAHs in common between the United States Environmental Protection Agency and the European Food Safety Authority lists of priority pollutants were separated in less than 7 min, while 19 PAHs, also targeted by these institutions, were separated in less than 18 min. These CE separation methods were successfully applied to the analysis of spiked edible oil extracts.The second part aimed at transferring the electrophoretic separation method of the 8 PAHs from the capillary to the microsystem format. The lack of sensitivity of the detection system hyphenated with chips was the main difficulty encountered. Thus, injected sample amounts and detection parameters were first optimized with a model compound in a borate buffer. However, only 4 out of the 19 PAHs, previously studied in CE, could be detected. Nevertheless, under conditions predicted by the design of experiments, they were baseline resolved in less than 4 min.Finally, several molecularly imprinted polymers (MIPs) were synthesized for the selective extraction of PAHs from oils. After a screening of synthesis conditions, the selectivity of each MIP was evaluated in pure media by comparing the extraction recoveries obtained on MIP with those obtained on a non-imprinted polymer. Finally, the 8 PAHs in common between the two lists were selectively extracted from sunflower oils, but with low recoveries. Improvements in extraction procedures are still required.
37

Etude de cristaux photoniques et de polymères stimulables : réalisation d'un capteur de nanoparticules / Studies of photonic crystals and stimulable polymers for the detection of nanoparticles

Bourdillon, Céline 07 October 2016 (has links)
L’essor des techniques d’analyse à l’échelle nanométrique a initié la synthèse et le développement de nombreuses nanostructures et nanoparticules. De par les propriétés spécifiques induites par leur taille, ces nanoparticules sont à présent omniprésentes dans la vie quotidienne et leur utilisation introduit de nouveaux enjeux environnementaux et toxicologiques. Il est donc important de pouvoir les capter et les détecter à l’état de trace en fonction de leur taille et de leur chimie de surface, deux facteurs dont dépend leur toxicité. Ce travail de thèse porte sur l’association des propriétés optiques d’un cristal photonique, l’opale, et des propriétés de reconnaissance d’un polymère stimulable, le polymère à empreintes de nanoparticules, afin de réaliser un capteur sensible, spécifique et sélectif (notamment en revêtement de surface) de nanoparticules. Les nanoparticules cibles que nous avons étudiées sont des nanocristaux fluorescents de CdSeTe/ZnS. Cette thèse se décompose en deux parties : dans la première, nous avons étudié le filtrage de l’émission des nanocristaux cibles par des hétérostructures à base d’opales directes. Dans la seconde partie, nous avons synthétisé, pour la première fois à notre connaissance, un polymère à empreintes de nanocristaux, en nous basant sur les travaux réalisés dans le cadre des polymères à empreintes moléculaires. Ce polymère a été utilisé pour réaliser une opale inverse permettant la détection de ces nanoparticules à partir de mesures de réflectivité. Ce capteur est généralisable à toute nanoparticule présentant une fonctionnalisation de surface. / Since the emergence of analysis techniques at the nanometer scale, many nanostructures and nanoparticles have been elaborated. Because of the specific properties induced by their size, nanoparticles are present in a lot of products used in the everyday life and can present a high toxicity. This toxicity depends, inter alia, on their size and surface chemistry. Therefore, it is really important to collect and detect them specifically when they are present as trace contaminants. This thesis deals with the combination of the optical properties of a photonic crystal, an opal, and the chemical properties of a stimulable polymer, a nanoparticles imprinted polymer, to realize a sensitive, specific and selective nanoparticles sensor. The nanoparticles that we used as targets are fluorescent CdSeTe/ZnS nanocrystals. In the first part of this thesis, we studied the filtering of the emission of the targets by heterostructures based on direct opals. In the second part, we synthetized, for the first time to our knowledge, a polymer presenting nanocrystals imprints. We used this polymer to realize an inverse opal allowing the sensing of these nanoparticles by specular reflection measurements. This sensor can be generalized to any functionalized nanoparticle.
38

Développement de nouveaux monomères biosourcés à base d’Isosorbide et applications à la synthèse de matériaux à applications spécifiques / Development of new biosourced monomers based on Isosorbide and applications to the synthesis of materials with specific applications

Saadaoui, Asma 03 March 2017 (has links)
L'isosorbide et ses dérivés sont des diols chiraux issus de l'amidon de maïs. L'utilisation de ce dernier en tant que monomère pour l'élaboration de polymères s'est révélée efficace, ces derniers égalant les propriétés des polymères conventionnels. Dans le cadre de cette thèse, ces diols sont employés pour synthétiser de nouvelles plateformes des monomères biosourcés AA et AB à partir des 1,4 :3,6- dianhydrohexitols. La synthèse d'intermédiaires à base de dinitriles ou de mononitriles et leurs dérivés à partir des trois isomères ainsi que les résultats d'essais de polymérisation de l'un de ces monomères prometteurs ont été décrits. Le polymère obtenu a révélé semi-cristallin grâce à l'agencement stéréorégulier des monomères AB. Ce travail est aussi le premier à décrire l'utilisation des réticulants chiraux à base de 1,4 :3,6-dianhydrohexitols participant à la formation du réseau tridimensionnel pour l'élaboration de polymères à empreintes (MIP) biosourcés pour la détéction de la Méthyltestostérone (MT). Les polymères synthétisés par polymérisation par précipitation ont été caractérisés. Les propriétés de rétention ont été évaluées en mode batch par HPLC-MS/MS. Ces MIPs présentent de bonnes propriétés d'adsorption vis-à-vis la MT avec des facteurs d'empreinte supérieurs à 1 montrant l'efficacité de l'impression. Ces matériaux présentent une bonne capacité d'adsorption comparée à la littérature. Les polymères non imprimés (NIP) ont même montré des capacités d'adsorption supérieure aux MIP classiques. La capacité d'adsorption la plus élevée a été observée pour cMIP-Is à base d'isosorbide, pour les concentrations importantes (500 mg L-1). Les données expérimentales ont été étudiées selon les modèles d'adsorption de Langmuir et Freundlich pour interpréter les phénomènes d'adsorption. Ces cMIP développés ont été adaptés pour l'extraction de la méthyltestotérone sur phase solide (SPE). Une procédure d'extraction a été développée en menant au travers d'une optimisation complète finalisée par une application aux eaux usées / The isosorbide and its derivatives are chiral diols obtained from cornstarch. The use of the latter as a monomer for the development of polymers has proved to be effective. The diols match the properties of conventional polymers. As part of this thesis, the diols are used to synthesize new platforms of bio based AA and AB from the 1,4: 3,6 - dianhydrohexitols monomers. The synthesis of intermediaries based on dinitriles or mononitrilies and their derivaties starting from the three isomers as well as the test results from one of these promising monomers polymerization which have been described. The resulting polymer revealed semi-cristallin through stereoregulier AB monomers layout. This work is also the first to describe the use of the reticulants chiral at base of 1.4: 3, 6-dianhydrohexitols participating in the formation of three-dimensional network for the development of polymers to footprints (MIP) Excelsior for detection of Methyltestosterone (MT). The polymers synthesized by polymerization have been characterized by precipitation. The properties of retention were evaluated in batch mode by HPLC-MS/MS. These MIPs present good properties of adsorption towards the MT with factors of footprint greater than 1 showing the effectiveness of printing. These materials have a good ability of adsorption compared to literature. Unprinted polymers (PIN) have shown even greater adsorption capacity than the conventional MIP. The high adsorption capacity was observed in cMIP-Is based on isosorbide for the concentrations (500 mg L-1). The experimental data have been studied according to Langmuir and Freundlich adsorption models to interpret the phenomena of adsorption these developed cMIP have been adapted for the methyltestoterone on the phase of extraction (SPE) solid. An extraction procedure has been developed leading through a full optimization finalized by an application in wastewater
39

Elaboration of a new sensor based on molecularly imprinted polymers for the detection of molecules in physiological fluids / Elaboration de polymères à empreinte moléculaire pour la détection optique de molécule dans un fluide physiologique

Marie, Héléne 19 December 2013 (has links)
Ce travail de thèse avait pour objectif l'élaboration d'un capteur optique pour la détection directe de molécules d'intérêt dans un fluide biologique. Deux stéroïdes et un xéniobiotique (herbicide) ont été choisis en tant que biomarqueurs apparaissant dans des fluides corporels : respectivement l'acétate de cyprotérone, le cortisol et l'acide 2,4 dichlorophénoxyacétique. La partie détection, d'une part, est assurée par les polymères à empreintes moléculaires (MIPs, de l'anglais Molecularly Imprinted Polymers). Ces récepteurs synthétiques sur mesure présentent en effet de nombreuses qualités pour l'intégration dans un capteur. Des polymères à empreintes moléculaires ont ainsi été développés pour les analytes visés. L'optimisation des formulations de polymère a été basée sur des plans d'expériences. La transduction optique, d'autre part, est basée sur la structuration du polymère sous la forme d'un cristal photonique. Des opales ont été fabriquées avec un procédé industrialisable pour permettre la mise en forme du MIP en opale inverse. Ainsi structuré à l'échelle submicronique, le matériau présente une couleur susceptible d'évoluer lors de la détection de l'analyte, et ce, grâce à un changement de conformation (gonflement). Les formulations polymères étudiées ont généré des gonflements réduits mais visibles en spectrophotométrie. Le travail rapporté dans cette thèse consiste donc en l'élaboration de polymères à empreintes moléculaires et leur intégration dans un capteur afin de détecter un analyte de façon directe, rapide et ne nécessitant que des équipements transportables, voire portables. / This thesis aimed at elaborating an optical sensor to detect molecules in a biological fluid. Two steroids and a xenobiotic were identified as biomarkers released in some body fluids: cyproterone acetate, cortisol and 2,4-dichlorophenoxyacetic acid respectively. On one hand, detection was performed by Molecularly Imprinted Polymers (MIPs). These tailor-made synthetic receptors display numerous qualities that foster their integration in sensors. MIPs were therefore developed against the targeted analytes. Formulation optimization was led thanks to experimental designs. On the other hand, optical transduction was made possible thanks to the structuring of a polymer into a photonic crystal. Opals were manufactured with a new process suitable for large scales and were used to mold MIPs in inverse opals. Thus, submicron structures of the polymer are responsible for the color of the sensor. A change of color is triggered by the recognition of the analyte by the polymer (upon swelling). Polymers studied displayed sufficient swelling observed by spectrophotometry. Finally, the work of this thesis consisted in elaborating polymer formulations and their integration in a sensor so as to detect an analyte with direct, rapid and unobtrusive means.
40

Techniques modernes de diagnostic paraclinique non invasif du déficit en cellules souches limbiques : comparaison, développement, recommandations / New minimally invasive techniques for diagnosing limbal stem cell deficiency : comparison, development and recommendations

Poli, Muriel 17 October 2014 (has links)
Optimiser le diagnostic paraclinique prédictif et non invasif du déficit en cellules souches limbiques (DCSL) : in vitro après empreinte cytologique (EC) par la recherche immunohistochimique (IH) de marqueurs pertinents et par reverse-transcription polymerase chain reaction (RT-PCR), technique de haute sensibilité ; in vivo par microscopie confocale (MCIV). Matériel et Méthodes: La preuve diagnostique de DCSL est la présence de cellules conjonctivales au sein de la cornée, la persistance de cellules cornéennes signant un DCSL partiel. L'EC a été standardisée. La spécificité de chacun des marqueurs cornéens ou conjonctivaux sélectionnés a été recherchée sur des tissus normaux avant d'aborder une étude prospective monocentrique, sur 22 yeux de 18 patients cliniquement suspects de DCSL. Les cellules épithéliales de la cornée centrale étaient recueillies par EC puis transférées sur lame. L'expression des marqueurs de différentiation conjonctivale (K7, K13, K19, MUC5AC) et cornéenne (K12) a été recherchée par IH sur les 22 EC et celle de la MUC5AC par RT-PCR sur 4 d'entre elles. Enfin, la cornée et le limbe de 7 patients ont étés analysés par MCIV. La concordance entre les techniques est évaluée. Conclusion: Ces techniques complémentaires dépendent de l'équipement du service et de l'accessibilité à un laboratoire compétent. Un organigramme décisionnel a été établi pour permettre de faire un diagnostic fiable de DCSL, les examens paracliniques étant inutiles dans certains cas. La recherche IH de kératines conjonctivales K7/K13 et/ou la détection de MUC5AC par RT-PCR sur cellules cornéennes recueillies par EC sont des techniques diagnostiques de haute valeur scientifique, tandis que l'IH K12/MUC5AC doit être abandonnée pour manque de sensibilité et celle de K3/K19 pour manque de spécificité. La MCIV, quand elle est réalisable, est une technique hautement sensible qui permet une quantification du degré de sévérité de la maladie avec une forte concordance avec les autres examens / Purpose: to optimize minimally invasive techniques for diagnosing limbal stem cell deficiency: in vitro after impression cytology (IC) by means of immunocytochemical detection of relevant markers and reverse-transcription polymerase chain reaction (RT PCR), an highly sensitive method; in vivo by confocal microscopy (IVCM). Material and Methods: Presence of conjunctival cells in central cornea was diagnosis proof of LSCD, whereas corneal epithelial cells’ remaining traduces partial LSCD. IC was labeled. Corneal or conjunctival specificity of each marker was previously assessed on healthy tissues. In a prospective case control observational study, 22 eyes of 18 patients clinically suspected of LSCD were enrolled. Epithelial cells from central cornea were collected by IC. Conjunctival (K7, K13, K19, MUC5AC) and corneal (K12) differentiation markers were assessed by immunocytochemistry on each of 22 eyes and MUC5AC RT-PCR was assessed for 4 of them. Cornea and limbus of 7 eyes were assessed by IVCM. The inter-examination agreement was determined. Conclusion: These techniques require skilled technicians and laboratory facilities. We propose a decision tree model to provide unfailing LSCD diagnosis, complementary examinations being sometimes useless. Clinical examination can lead to LSCD misdiagnosis. Immunostaining of conjunctival keratins K7 and K13 as well as MUC5AC detection by RT-PCR are highly effective methods whereas MUC5AC/K12 immuno staining are not sensible and both K3 and K19 are not specific. IVCM of great sensitivity if realizable allows quantification of LSCD severity. Combining both methods provides in every case unfailing diagnosis of LSCD and evaluation of the extent of the disease with high agreement

Page generated in 0.1092 seconds