• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 72
  • 40
  • 17
  • 3
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 154
  • 42
  • 42
  • 42
  • 34
  • 25
  • 23
  • 21
  • 18
  • 14
  • 14
  • 13
  • 12
  • 12
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

An In Vitro Evaluation of the Elements Apex Locator Using the Endo Q System

Brofsky, Steven Andrew 01 January 2004 (has links)
The objective of this study was two-fold: 1) to determine the accuracy of the Elements Apex Locator and 2) to compare the accuracy of the alginate and Endo Q models as in-vitro apex locator testing devices. Twenty teeth were decoronated at the CEJ and triplicate measurements were made using the Elements Apex Locator. All measurements were made to the apex reading of the apex locator. True length was established by visualizing the file tip at the apex with a dental operating microscope. Measurements were then taken with the teeth mounted in an alginate model and then in the Endo Q model. The two models were compared using a repeated-measure ANOVA. Statistically significant differences occurred between the alginate and Endo Q models. The results showed that in 95% (n=19) of the cases, an accurate location to within + 0.5 mm of the apical foramen was obtained with the Endo Q model and 55% (n=11) with the alginate model. With a + 1.0 mm tolerance level, an accuracy of 95% (n=19) was found with the use of the alginate model. In conclusion, it seems that the Endo Q system was more suitable for testing the electronic apex locator than the alginate model. The Elements Apex Locator with the use of the Endo Q model was highly accurate in locating to within + 0.5 mm of the apical foramen (Mean deviation = .17 mm).
52

Implantes de zircônia reforçada com ítria (Y-TZP): avaliação histomorfométrica / Y-TZP dental implants: histomorfometry analysis

Martins, Renato 14 November 2013 (has links)
O objetivo do trabalho foi avaliar in vivo a osseointegração de implantes produzidos em zircônia reforçada com ítria (Y-TZP) e compará-los com o implante de titânio usinado e com o de superfície jateada com brushita. Para tanto, nas tíbias de 20 coelhos machos (n=10) e fêmeas (n=10) foram implantadas em uma das tíbias o implante Y-TZP (GE-1, n=10 implantes) e na outra tíbia o titânio usinado (GC, n=5 implantes) ou jateado com brushita (GE-2, n=5 implantes). Os animais receberam marcadores ósseos fluorescentes, tetraciclina (14 e 21 dias), alizarina (28 e 35 dias) e calceína (42 e 49 dias) após a cirurgia de implantação. Ao final de 56 dias, a região dos implantes foi coletada e processada histologicamente para obtenção de cortes teciduais não desmineralizados. Nas imagens obtidas no microscópio confocal foi avaliado o percentual de área para cada marcador. Nos cortes corados pelo azul de toluidina foi avaliado morfologicamente a qualidade do tecido ósseo formado e a existência de interposição de tecido conjuntivo entre osso e implante, e morfometricamente determinado o percentual de contato osso-implante (BIC) e o percentual de tecido ósseo próximo à superfície do implante (BA). Os resultados mostraram que, não houve diferenças estatisticamente significantes entre machos e fêmeas quanto aos parâmetros avaliados. Com relação aos grupos, GE-1 e GC apresentaram cortical óssea remanescente íntegra e formação de um tecido ósseo maduro/lamelar na superfície dos implantes. No GE-2 ocorreu intensa reabsorção da cortical óssea pre-existente próxima ao implante e extensa formação óssea mais imatura em relação aos observados no GE-1 e GC. Essa intensa reabsorção e extensa formação óssea fez com que o percentual de área dos marcadores fluorescentes fosse em média 0,73 vezes maior no GE-2 em relação aos grupos GE-1 e GC. Com relação ao BIC não houve diferença entre os grupos, sendo em média de 47,8%, porém, o BA no grupo GC (66,2%) foi 0,33 vezes maior em relação ao GE-1(51,6%) e GE-2 (48,2%). No modelo utilizado o implante Y-TZP apresentou osseointegração similar ao titânio usinado e superior ao jateada com brushita, podendo ser considerado uma alternativa para substituir o implante titânio quando a estética esta envolvida. / The aim of this work was evaluate in vivo the osseointegration of implants produced with yttria stabilized zirconia (Y-TZP) and compare it with machined titanium implant and sandblasted surface with brushita titanium. Therefore, on the tibia of 20 rabbits males (n=10) and female (n=10) were implanted in one of the tibias the implant Y-TZP (GE-1, n=10 implants) and on the other tibia the machined titanium (GC, n=5 implants) or sandblasted surface with brushita titanium (GE-2, n=5 implants). The animals received fluorescent bone markers, tetracycline (14th and 21th days), alizarin (28th and 35th days) and calcein (42th and 49th days). At the end of 56 days, the implants regions were collected and histomorphometrically processed to obtain tissue sections not demineralized. On images obtained from confocal microscopy was evaluated the percentage of area for each bone markers. On slides stained with toluidine blue was measured morphologically the quality of formed bone tissue and the existence of interposition of connective tissue between bone and implant, and was morphometrically determined the percentage of bone-implant contact (BIC) and the percentage of bone tissue next to the implant surface (BA). The results showed that there were no statistically significant differences between male and female regarding to evaluated parameters. Concerning to the groups, GE-1 and GC exhibited wholesome remaining cortical bone and formation of mature/lamellar bone tissue on implants surface. In GE-2 ocurred intense reabsorption of preexisting cortical bone next to the implant and extensive bone formation more immature than GE-1 and GC. This intense reabsorption and extensive bone formation made the GE-2 area percentage for fluorescent markers 0.73 times higher on average when compared to GE-1 and GC. About the BIC, there were no differences between the groups, with an average of 47.8%, however, the BA on GC group (66.2%) was 0.33 higher compared to GE-1 (51.6%) and GE-2 (48.2%). In the model used, the Y-TZP implant exhibited osseointegration suchlike machined titanium and better than sandblasted surface with brushita titanium, being considered an alternative to replace the titanium implant when aesthetics is involved.
53

Evolução dos sistemas de retenção, fixação e ancoragem extraoral na reabilitação bucomaxilofacial: revisão sistemática / Evolution of retention, fixation and anchorage extraoral in maxillofacial rehabilitation systems: a systematic review

Cobein, Marcus Vinicius 02 July 2014 (has links)
Introdução: A utilização de próteses bucomaxilofaciais é de extrema importância para a reintegração no convívio social dos pacientes acometidos de deformidades congênitas ou adquiridas. Tendo em vista os avanços dos sistemas de retenção, fixação e ancoragem extraoral na reabilitação bucomaxilofacial realizou-se revisão sistemática. Objetivos: verificar a evolução das retenções das próteses bucomaxilofaciais comparando os sistemas osseointegrados, aos sistemas não osseointegrados, analisando algumas variáveis como: taxa de sobrevivência dos implantes ao longo do tempo, idade média dos pacientes, etiologia do defeito facial e sitio dos sistemas de retenção relacionado ao tipo de prótese, em formato de revisão sistemática. Métodos: Realizou-se busca bibliográfica nas bases de dados PubMed e SCOPUS, após elaboração de estratégias de busca, obteve-se 2630 artigos onde foram analisados títulos, resumos e eliminadas duplicidades. Resultados: Obteve-se 25 artigos pré-selecionados que passaram pelos critérios de inclusão e exclusão sendo eleitos 13 artigos para a revisão sistemática. Conclusão: As próteses retidas por implantes superam os sistemas convencionais. A perda dos implantes foi muito pequena nos estudos analisados, apesar do tempo de acompanhamento ser relativamente curto e dos protocolos distintos de tratamento. A idade adulta entre a quarta e quinta década de vida foi a de maior prevalência. A etiologia mais incidente são as neoplasias. Os sistemas osseointegrados fixados por implantes por retenção barra clipe se localizam mais na região auricular e retenção magnética nas regiões nasal e orbital. Os sistemas não osseointegrados, a retenção anatômica é mais utilizada na região ocular, retenção mecânica na região orbital e o uso da retenção por adesivos nas regiões nasal e orbital. / Introduction: The use of maxillofacial prostheses is the most importance for reintegration into social life of patients suffering from congenital or acquired deformities. Given the advances in retention, fixation and extraoral anchorage systems in maxillofacial rehabilitation got systematic review. Objectives: To observe the evolution of the retentions of maxillofacial prostheses comparing osseointegrated systems, non osseointegrated systems, analyzing some variables such as survival rate of implants over time, mean patient age, etiology of facial defect and place restraint systems related kind of prosthesis, in a systematic review format. Methods: We performed a literature search in PubMed and SCOPUS database, after preparation of search strategies, we obtained 2630 articles where were checking titles, abstracts and eliminated duplicates were analyzed. Results: We obtained 25 pre-selected articles that passed the criteria for inclusion and exclusion being elected 13 articles for systematic review. Conclusion: The dentures retained by implants outperform conventional systems. The loss of the implants was very small in the analyzed studies, although the follow-up time is relatively short and the different treatment protocols. Between the fourth and fifth ages of life was the most prevalent. The most frequent etiology are neoplasms. Osseointegrated systems for fixed for implants retention bar clip are located more auricular and magnetic retention in the regions nasal and orbital. Non osseointegrated systems, anatomical retention is most commonly used in the ocular region, mechanical retention in orbital region and the use of adhesives for retention in the regions nasal and orbital.
54

Avaliação do copolímero de ácido polilático e poliglicólico ao redor de implantes osseointegráveis sem estabilidade primária : análise biomecânica, histométrica e imunoistoquímica em coelhos /

Queiroz, Thallita Pereira. January 2006 (has links)
Resumo: A proposta deste estudo foi avaliar a associação do PLA/PGA ao redor de implantes osseointegráveis instalados sem estabilidade primária, por meio da análise biomecânica, histométrica e da expressão das proteínas OPG, RANKL, OC e COL-I. Vinte e cinco coelhos receberam 2 implantes de 2,6/ 6,0mm na tíbia direita em leitos receptores preparados com 3,0mm. Um defeito foi preenchido com coágulo sanguíneo e o outro com o PLA/PGA previamente à instalação dos implantes. A eutanásia dos animais foi realizada nos períodos de 5, 15, 40 e 60 dias pósoperatórios e o teste biomecânico foi realizado nos períodos de 40 e 60 dias. As peças foram submetidas ao processamento imunoistoquímico e coradas por HE. As peças de 5 animais do período de 60 dias foram desgastadas e coradas com vermelho de alizarina e azul de Stevenel. Não houve diferenças nos valores de torque-reverso na comparação entre os grupos e os períodos avaliados. A análise das imunomarcações não evidenciou diferença estatística entre os grupos para cada período. Houve evidência estatística de maior expressão de RANKL no período de 15 dias no grupo tratado em relação à expressão de colágeno I. A proteína RANKL apresentou mais percentuais de marcações celulares acima de 50% quando comparada às outras proteínas. Não houve diferença estatística entre os grupos quanto à extensão linear de contato entre tecido ósseo e implante. Conclui-se que o copolímero apresentou biocompatibilidade e permitiu neoformação óssea em contato com o implante. Além disso, ocorreu o processo de osseointegração em ambos os grupos, mesmo na ausência de estabilidade primária dos implantes. / Abstract: The purpose of this study was to evaluate the association of the PLA/PGA around of osseointegrated implants installed without primary stability, through the biomechanics, histometric analysis and of the OPG, RANKL, OC and COL-I proteins expression. Twenty-five rabbits received 2 implants of 2.6 / 6.0mm in the right tibia in receptor beds prepared with 3,0mm. A defect was fulfiled with blood clot and the other with the PLA/PGA, previously to the implants installation. The euthanasia of 25 animals was performed at 5, 15, 40 and 60 days and the biomechanical test was performed at 40 and 60 days. The samples followed immunoistochemistry processing and were stained with HE. The pieces of 5 animals of 60 days were trimmed and stained with alizarin red and Stevenel's blue. There were not differences in the torque-reverse between the groups and periods. The analysis of the immunolabelings did not evidence statistic difference between the groups for each period. There was statistics evidence of increase in the RANKL expression in the 15 days period, in the treated group, when compared to the COL-I. The RANKL protein presented more percentiles of immunolabelings above 50% when compared to the other proteins. There was no statistics difference between the groups regarding contact linear extension between bone tissue and implant. It can be concluded that the copolymer presented biocompatibility and it allowed bone neoformation in contact with the implant. Besides, the osseointegration process happened in both groups, even in the absence of primary stability of the implants. / Orientador: Eduardo Hochuli Vieira / Coorientador: Roberta Okamoto / Banca: Idelmo Rangel Garcia Júnior / Banca: Cássio Edvard Sverzut / Mestre
55

Aplicação do copolímero PLA/PGA adicionado ao fosfato de cálcio ao redor de implantes osseointegráveis instalados sem estabilidade primária em tíbia de coelhos : estudo biomecânico, histométrico e imunoistoquímico /

Souza, Francisley Ávila. January 2006 (has links)
Resumo: Aplicação do copolímero PLA/PGA adicionado ao fosfato de cálcio ao redor de implantes osseointegráveis sem estabilidade primária instalados em tíbia de coelhos. Estudo biomecânico, histométrico e imunoistoquímico." Proposição: O objetivo do presente trabalho foi avaliar comportamento mecânico e biológico do tecido ósseo ao redor de implantes associados ao copolímero ácido polilático/poliglicólico adicionado ao fosfato de cálcio. Materiais e Métodos: Para tal foram usados vinte e cinco coelhos Albinus. Após procedimento cirúrgico os animais foram divididos em 4 períodos, sendo o último período, 60 dias, composto por 10 animais. Os animais tiveram perfurações realizadas com sobrefresagem na porção medial das tíbias direita e esquerda. Na tíbia direita o leito cirúrgico foi preenchido com coágulo sanguíneo e na tíbia esquerda com o copolímero. Em ambos leitos cirúrgicos a instalação dos implantes osseointegráveis ocorreu imediatamente após a fresagem. Nos períodos de 5, 15, 40 e 60 dias os animais foram anestesiados e sofreram eutanásia por meio de perfusão de Formaldeído 4% no ventrículo esquerdo. Nos períodos de 40 e 60 dias realizou-se o torque reverso para remoção dos implantes. As peças dos 5 animais restantes do período de 60 dias foram levadas ao micrótomo Exakt para realização de cortes histológicos com os implantes. Nas demais peças, realizou-se análise imunoistoquímica mediante a utilização dos anticorpos primários contra as proteínas OPG, RANK e RANKL. Resultados: As médias de torque para o grupo controle foram de 10,2 e 5,6 N/cm nos períodos de 40 e 60 dias respectivamente, enquanto para o grupo tratado foram de 7,6 e 7,0 N/cm nos mesmos períodos. Houve um balanço na expressão das proteínas com leve predomínio de RANKL. / Abstract: Application of PLA/PGA copolymer added to calcium phosphate around osseointegrated implants with no primary stability in rabbits's tibia. A biomecanical, histometric and immunohistochemistry study. Purpose: The aim of the present study was to evaluate the mechanical and biological behaviour of bone tissue formed around the implants associated to copolymer polilactic/poliglicolic acids added to calcium phosphate. Materials and Methods: In the present study, twenty five Albinus rabbits, divided in 4 periods, and the last period, referred to 60 days, was composed by 10 animals. The animals had perfurations performed with osteotomy in the medial portion of right and left tibias. In the right tibia, the surgical bed was filled with blood clot and in the left tibia, the copolymer was used. In the same way in both surgical beds, the osseointegrated implants installation occurred immediately after the osteotomy. In the periods of 5, 15, 40 and 60 days, the animals were anesthetized and were sacrificed by perfusion with 4% formaldehyde, in the left ventricule. In the periods of 40 and 60 days, the reverse torque was performed in order to remove the implants. The pieces of the 5 remaining animals of the 60 days period were processed in the Exakt microtome in order to realize undecalcified histological sections with the implants. In the other pieces, the immunohistochemical analysis was performed in order to detect the presence of the OPG, RANK and RANKL proteins in the bone tissue. Results: The mean of torque for the control group were 10.2 and 5.6 N/cm in the periods of 40 and 60 days respectly, while in the treated group were 7.6 and 7.0 N/cm in the same periods. There was a balance in the expression of the proteins with moderate predominance of RANKL protein. There were no statistically differences between the groups in relation to the linear extension of contact between bone and implant. / Orientador: Roberta Okamoto / Coorientador: Eduardo Hochuli Vieira / Banca: Idelmo Rangel Garcia Júnior / Banca: Sérgio Bruzadelli Macedo / Mestre
56

Avaliação da influência da força de mordida na prótese parcial removível classe I mandibular associada ao implante osseointegrado, pelo método dos elementos finitos /

Lucas, Liliana Vicente Melo de. January 2003 (has links)
Orientador: Eduardo Piza Pellizzer / Resumo: A associação entre as próteses parciais removíveis e os implantes osseointegrados é, ainda, uma opção de tratamento muito pouco explorada na Odontologia reabilitadora moderna. Por isso, o objetivo deste estudo é avaliar, utilizando o método dos elementos finitos bidimensional, a distribuição de tensão nas estruturas de suporte da prótese parcial removível de extremidade livre (PPREL) associada a um implante osseointegrado de 10,0 x 3,75 mm (Sistema Branemark), localizado na região posterior do rebordo alveolar desdentado, atuando como suporte para a base da prótese. Para tanto, foram criados três modelos, os quais, em corte sagital, representam: modelo A (MA) - hemiarco contendo o dente natural 33 somente e o A rebordo desdentado distal; modelo B (MB) - semelhante ao MA, com uma PPREL convencional substituindo os dentes ausentes; modelo C (MC) - semelhante ao anterior, com um implante na região posterior do rebordo, sob a base da prótese. Com o auxílio do programa de elementos finitos ANSYS 5.4, os modelos foram carregados com forças verticais e oblíquas de 45º, tanto no sentido de mesial para distal como no sentido inverso, de magnitude de 50 N, em cada ponta de cúspide. A análise dos mapas de tensões permitiu concluir que: 1) a tendência de deslocamento no modelo com a PPR apoiada sobre implante é menor que no modelo com a prótese somente; 2) as forças oblíquas de 45º promovem uma tendência de deslocamento e valores de tensão maiores que a força vertical; 3) a força oblíqua de 45º, no sentido de mesial para distal, gera valores de tensão menores que a de distal para mesial e 4) a presença do implante osseointegrado, sob a base da prótese, promove alívio do dente suporte. / Abstract: The association among the removable partial dentures and the osseointegrated implants is still a non very explored option of treatment in the modern prosthetic dentistry. Because of this, the objective of this study is to evaluate, using the two-dimensional finite element analysis, the tension distribution in the support structures of the distal extension removable partial denture (RPD) associated with a 10.0 x 3.75 mm osseointegrated implant (Branemark System), located in the posterior area of the toothless alveolar edge, acting as support for the prosthesis base. Then, three plane strain models were created, represented in sagital cut: Model A (MA) - hemiarc containing the natural tooth 33 and the toothless alveolar edge; Model B (MB) - similar to MA, with a conventional RPD substituting the absent teeth; Model C (MC) - similar to the previous, with an implant in the posterior area of the edge, under the denture base. With the aid of the finite element program ANSYS 5.4, the models were loaded with vertical and 45º inclined forces, in both mesial and distal sides, with 50 N, on each peak point. The analysis of the tensions map allowed to conclude that: 1) the displacement tendency in the model with the RPD supported by the implant is smaller than the model with prosthesis only; 2) the oblique forces of 45º promote a displacement tendency and larger tension values than the vertical force; 3) the mesial to distal 45º oblique force generates smaller tension values than the one of distal to mesial and 4) the presence of the osseointegrated implant, under the denture base, promotes relief to the support tooth. / Mestre
57

Influência da osteoporose e álcool na osseointegração de implantes em ratas /

Deco, Camila Porto de. January 2009 (has links)
Orientador: Leonardo Marchini / Banca: Rosilene Fernandes da Rocha / Banca: Célia Marisa Rizzatti Barbosa / Resumo: O consumo de álcool e a osteoporose, individualmente, podem afetar o metabolismo ósseo e ter influência negativa sobre tratamentos com implantes odontológicos, comprometendo sua estabilidade biomecânica. Entretanto, os efeitos da associação entre esses dois fatores na osseointegração de implantes é desconhecido. O objetivo deste trabalho foi investigar parâmetros histomorfométricos da osseointegração em ratas sob consumo de álcool associado à osteoporose. Noventa e seis ratas foram divididas conforme o tipo de dieta e quanto à presença ou ausência hormonal. Grupo G1: Sham (ovariectomia simulada), água e ração ad libitum; G2: Sham, ração e solução de etanol a 20% ad libitum; G3: Sham, ração e solução de sacarose controladas para assegurar uma dieta isocalórica à de G2; G4: ovariectomia, água e ração ad libitum; G5: ovariectomia, ração e solução de etanol a 20% ad libitum; G6: ovariectomia, ração e solução de sacarose controladas para assegurar uma dieta isocalórica à de G5. Cada grupo foi subdividido em A e B, de acordo com o tempo de osseointegração: 4 ou 6 semanas, respectivamente. Um mês após a ovariectomia ou Sham foi iniciada a dieta e um mês depois foi realizada a cirurgia para colocação dos implantes de titânio nos fêmures dos animais. Após a eutanásia, os fêmures foram avaliados por histomorfometria para quantificação da superfície de contato direto entre osso e implante. Os grupos G5 e G6 foram os que apresentaram a menor porcentagem de contato direto ossoimplante quando comparados aos demais. Conclusão: A associação entre a deficiência estrogênica, provocada pela ovariectomia, e o consumo crônico de álcool pode prejudicar a osseointegração, assim como a associação entre deficiência estrogênica e redução no consumo de nutrientes. / Abstract: Alcohol intake and osteoporosis can, separately, affect bone physiology and have presented negative impacts on dental implant therapy. However, the effects of the association of both factors in the osseointegration are unknown. The aim of this study was evaluate osseointegration in rats alcohol fed and presenting induced osteoporosis. Methodology: Ninety-six female rats were divided according to diet and hormonal condition. Group G1: Sham (simulated ovariectomy), food and water ad libitum; G2: Sham, food and ethanol 20% solution ad libitum; G3: Sham, food and sucrose solution controlled to warranty an isocaloric diet in relation to G2; G4 ovariectomy, food and water ad libitum; G5 ovariectomy, food and ethanol 20% solution ad libitum; G6: ovariectomy, food and sucrose solution controlled to warranty an isocaloric diet to G5. The groups were subdivided according to time of osseointegration 4 or 6 weeks. Implants surgery was done one month after ovariectomy or Sham. After euthanasia, the femurs were removed and evaluated by histomorfometry. Results: Groups G5 and G6 showed the worse osseointegration condition. Conclusion: The association between estrogen deficiency and alcohol intake and the association between estrogen deficiency and reduced intake of nutrients can negatively affect osseointegration. / Mestre
58

Influência do tipo de conector na união dente e implantes de hexágono interno e externo : estudo pelo método da fotoelasticidade /

Silva, Edmar Ferreira da. January 2006 (has links)
Resumo: A união dente-implante ainda gera divergências de opiniões. A proposta deste estudo foi avaliar pelo método da fotoelasticidade a distribuição do stress entre implantes e dentes, nas próteses parciais fixas, comparando conectores rígidos e semi-rígidos e implantes de hexágono interno e externo. Para isto, foram confeccionados dois modelos com resina fotoelástica PL-2, um com implante de hexágono interno (3i - Palm Beach Gardens, Fla. - 4,00 x 13 mm) e outro com implante de hexágono externo (3i - Palm Beach Gardens, Fla. - 4,00 x 13 mm). Três desenhos de próteses foram fabricados para cada modelo de implante, incorporando cada uma um tipo de conexão para unir implantes e dentes: 1) conexão rígida soldada; 2) conexão semi-rígida; 3) conexão rígida com parafuso oclusal. Os modelos foram colocados no polariscópio e cargas axiais de 100N foram aplicadas em pontos fixos na superfície oclusal das próteses. Os resultados mostraram tendência a uma menor intensidade nas tensões nas conexões semi-rígida e rígida soldada no modelo com implante de hexágono externo e maior intensidade nas tensões na conexão semi-rígida do hexágono interno. Dentro das limitações deste estudo, as seguintes conclusões foram obtidas: houve uma tendência a menor intensidade nas tensões na conexão semi-rígida e na conexão rígida soldada, no modelo com implante de hexágono externo; entre os três tipos de conexões no modelo com implante de hexágono interno, a conexão semi-rígida foi a mais desfavorável; na associação dente-implante é preferível a utilização do implante de hexágono externo. / Abstract: The union tooth-implant still generate divergences of opinions. The purpose of this study was to examine for the photoelastic metod, the distribution of stress among implants and teeth, in the fixed partial prostheses, comparing rigid and semi-rigid connectors and internal and external hexagon implants. For this, two models were made with photoelastic resin PL-2, one with internal hexagon implant (3i - Palm Beach Gardens, Fla. - 4,00 x 13 mm) and other with external hexagon implant (3i - Palm Beach Gardens, Fla. - 4,00 x 13 mm). Three drawings of prostheses were manufactured for each implants model, incorporating each an the connection type to unite implants and teeth: 1) rigid welded connection; 2) semi-rigid connection; 3) rigid connection with screw oclusal. The models were placed in the polariscope and axial loads of 100N were applied in fixed points in the surface oclusal of the prostheses. The results showed tendency to smaller intensity in tensions in the connections semi-rigid and rigid welded in the model with external hexagon implants and larger intensity in the connection semi-rigid of the model internal hexagon implant. The following conclusions were draw: there was tendency the smallest intensity in tensions in the semi-rigid connection and in the rigid welded connection in the model with external hexagon; among the three types of connections in the model with internal hexagon implants the connection semi-rigid was the most unfavorable; in the association tooth-implants it is preferable the use of external hexagon implants. / Orientador: Eduardo Piza Pellizzer / Coorientador: Idelmo Rangel Garcia Júnior / Banca: Stefan Fiuza de Carvalho Dekon / Banca: Alcides Gonini Júnior / Mestre
59

Implantes osseointegráveis instalados sobre raízes reimplantadas tardiamente /

Cardoso, Leandro de Carvalho. January 2008 (has links)
Orientador: Wilson Roberto Poi / Banca: Idelmo Rangel Garcia Júnior / Banca: Daniele Botticelli / Banca: Hugo Alexandre de Souza / Banca: Maurício Zardo / Resumo: O objetivo deste trabalho foi analisar o reparo ósseo peri-implantar de implantes instalados sobre raízes dentárias reimplantadas tardiamente, apresentando processo de anquilose e reabsorção por substituição. Foram utilizados os terceiros e quartos pré-molares inferiores de 4 cães machos (Beagle). Os dentes foram seccionados, e as raízes mesiais extraídas e mantidas durante 1 hora em temperatura ambiente. Após a remoção do ligamento periodontal necrótico e tratamento endodôntico, imergiram-se em fluoreto de sódio por 5 minutos e reimplantou a porção no alvéolo esplintando nas porções distais. Nestas foram realizadas pulpotomia e restauração. Decorridos 30 dias, as porções mesiais tiveram suas coroas seccionadas. Após 5 meses, cinco implantes foram instalados em osso reparado, grupo I, (Controle); nove foram instalados nos alvéolos frescos pós-exodônticos das porções distais (Grupo II - Imediato) e doze implantes foram instalados sobre as raízes mesiais em processo de reabsorção radicular externa (Grupo III - experimental). Decorridos 120 dias, os resultados foram analisados pelo contato osso implante da superfície do implante sem roscas e das três primeiras roscas. Foi avaliada, também, a área de tecido ósseo presente nos espaços internos das três primeiras roscas e da área espelho correspondente. O contato osso implante foi de 55% no grupo controle, 48% no imediato e 40% no grupo experimental. A área de tecido ósseo foi, respectivamente, 71%, 61% e 55%, e a área espelho de tecido ósseo foi de 62%, 60% e 58%. Conclui-se que o reparo ósseo perimplantar de implantes instalados sobre raízes apresentou um pequeno em relação aos outros dois grupos. / Abstract: The purpose of this study was to analyze the peri-implant bone repair of dental implants placed on delayed reimplated roots, with process of ankylosis and reabsorption by substitution. The lower third and fourth pre-molar of four male dogs (Beagle) was used. The teeth were cut, and the mesial roots were extracted and kept out for 1 hour at ambient temperature. After removal of necrotic periodontal ligament and endodontic treatment, the root was immersed in sodium fluoride for 5 minutes. Then it was reimplanted in the correspondent alveolar bone and splinted in distal portion. A pulpotomy and a crown restoration were conducted on the distal portion. After 30 days, the mesial portions had their crowns cut (decoronation).Moreover, 5 months later, five implants were installed in bone repair, Group I (Control), and nine were installed in the fresh socket of the distal portions, which were extracted (Group II - Immediate). Finally, twelve implants were installed on the mesial roots, with process of external resorption (Group III - experimental). After 120 days, the results were analyzed by bone implant contact, from the surface of the implant without threads to the first three threads. It was also evaluated the area of the bone tissue located in the internal spaces of the first three threads and the corresponding mirror area. The bone implant contact was 55% in the control group, 48% in the immediate group and 40% in the experimental group. The area of bone tissue in the internal threads area was respectively 71%, 61% and 55%, and the mirror area of bone tissue had the following results: 62%, 60% and 58%. It was concluded that peri-implant bone repair of the implant put on the roots with an external resorption showed delay compared to the other two groups. / Doutor
60

Estudo da influência de corticóides no processo inicial de osseointegração de implantes de titânio instalados em maxilas de ratos /

Oliveira, Sérgio Ricardo de. January 2008 (has links)
Orientador: Valdir Gouveia Garcia / Banca: Maria José Hitomi Nagata / Banca: Álvaro Francisco Bosco / Banca: Ariel Lenharo / Banca: Jamil Awad Shibli / Resumo: As modalidades terapêuticas que envolvem implantes dentais têm se expandido gradativamente, sendo implantados em uma variedade de estruturas ósseas. Dessa forma, o propósito do presente trabalho foi estudar a influência de corticóides no processo inicial de osseointegração de implantes de titânio instalados em maxilas de ratos. Foram utilizados implantes de titânio c.p., grau II, cônico de 1,4mm de diâmetro e 2,7mm de comprimento, com superfície tratada. Trinta e oito ratos wistar tiveram seus primeiros molares superiores esquerdo e direito extraídos. Após 30 dias de reparo alveolar, dois animais foram sacrificados para confirmar o fim desse processo. Os demais animais tiveram os implantes instalados bilateralmente e foram divididos randomicamente em três grupos: Controle (Ctr/n=12) que não receberam nenhum tipo de tratamento; Placebo (Pl/n=12) e Tratado (Tra/n=12), que receberam injeções diárias de 1 ml de solução salina e corticosterona na dosagem de 5mg/kg, respectivamente. Trinta dias após a implantação, todos os animais foram eutanasiados e tiveram a concentração plasmática do corticóide mensurada: Ctr (101,31 ± 26,7 ng/ml), Pla (95,22 ± 25,36 ng/ml) e Tra (281,37 ± 64,72 ng/ml); e o contato osso-implante determinado: Ctr (96,67%), Pla (82,22%) e Tra (15,73%), nos quais o grupo Tra apresentou-se estatisticamente diferente dos demais grupos (p<0,05). Assim, diante da metodologia empregada, foram evidenciadas menor formação óssea e conseqüente redução da área de tecido ósseo neo-formado na interface osso-implante. / Abstract: The therapeutic modalities which involves dental implants has been gradually expanded, being implanted in a variety of bone structures. In this way, the aim of the present work was to study the corticoid influence at the initial process of bone integration of titanium implants installed in rat jaws. It were used titanium implants c.p.; grade II, conic with 1,4mm diameter and 2,7mm length, with treated surface. Thirty eight wistar rats had their first upper left and right molars extracted. After 30 days of alveolar repair, two animals were sacrificed to confirm the end of this process. The others had their implants installed bilaterally and they were splited randomly in three groups: Control (Ctr/n=12) which did not receive any kind of treatment; Placebo (Pla/n=12) and Treated (Tre/n=12) which received 1ml daily shots of salt solution and corticosterone at a dosage of 5mg/Kg, respectively. Thirty days after the implantation, all the animals were euthanasiated and the plasmatic concentration of corticoid was measured: Ctr (101,31 ± 26,7 ng/ml), Pla (95,22 ± 25,36 ng/ml) and Tre (281,37 ± 64,72 ng/ml); and the bone implant contact was determined: Ctr (96,67%), Pla (82,22%) and Tre (15,73%), in which the Tre group presented statistically different from the other groups (p<0,05). Thus, front the employed methodology it was shown lesser bone formation and consequent reduction of the bone tissue area neo-formed at bone-implant interface. / Doutor

Page generated in 0.0573 seconds