• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 70
  • 26
  • 6
  • Tagged with
  • 102
  • 41
  • 35
  • 32
  • 27
  • 27
  • 23
  • 23
  • 20
  • 20
  • 19
  • 19
  • 19
  • 17
  • 17
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Contribution à l'étude de la formation des sprays / Contribution to the study of spray formation

Dos Santos, Fabien 10 December 2012 (has links)
Le travail de cette thèse a pour but de fournir et valider des outils permettant d'étudier et de comprendre les phénomènes mis en jeu lors de l'injection d'un carburant dans un moteur à combustion interne, principalement axé sur l'écoulement intra-injecteur. Ces outils sont numériques et permettent de simuler la formation d'un spray. Une première partie est axée sur la modélisation 0D. Les modèles permettant de prédire des caractéristiques de spray comme son angle, sa pénétration ou encore la longueur du corps liquide, sont comparés à des données expérimentales. Les conclusions sont que la modélisation 0D permet d'obtenir de bons résultats. Par contre une meilleure connaissance de l'influence de la cavitation sur le spray, qui passe par la compréhension de l'écoulement intra-injecteur, pourrait être bénéfique pour la prédiction de ces modèles. Une seconde étude sur l'écoulement intra-injecteur est alors menée en utilisant un modèle à équation barotrope. Une validation de celui-ci est effectuée de façon à vérifier qu'il est capable de prédire correctement l'écoulement dans un injecteur. Le modèle offre de bons résultats et peut être utilisé pour l'étude suivante. Enfin, dans la dernière partie, le modèle de cavitation qui a été validé est utilisé. Une géométrie d'injecteur mono-trou est utilisée avec des pressions comparables à celles utilisées actuellement en automobile. L'étude consiste à étudier l'influence de plusieurs paramètres géométriques sur l'apparition de la cavitation. Le mouvement de l'aiguille est aussi étudié et est comparé, après avoir offert au code la possibilité de maillage mobile, à des résultats in-stationnaires pour plusieurs levées d'aiguille. / The work of this thesis aims to provide and validate tools useful to study and understand the phenomena involved in the injection of fuel, mainly focused on intra-flow injector. These tools are numeric and simulate the formation of a spray. A first part focuses on zero-dimensional modelling. Models which predict these following characteristics of spray like the spray angle, the spray penetration or the liquid length are compared with experimental data. The conclusions are that zero-dimensional modelling provides good results very quickly in some cases. Although, a better understanding of the influence of cavitation on the spray, which requires an understanding of the intra-flow injector, could be beneficial for the prediction of these models. A second study is carried out to select a model of multi-dimensional cavitation. The chosen model is a barotropic equation model. A validation of this model is then performed to ensure that it is able to predict the cavitating flow inside a nozzle. The model provides good results and can be used for the next step. Finally, in the third part, the cavitation model previously validated is used. Single-hole nozzle geometry is used with an injection pressure comparable to that used in internal combustion engines with direct injection system. The study is done to investigate the influence of several geometrical parameters on the onset of cavitation. The movement of the needle is also studied and compared, after offering to the code the possibility of moving mesh, to the results of several stationary needle lifts.
72

Experimental study of the thermal and rheological behaviour of paraffin-in-water emulsions used as a secondary refrigerants / Etude expérimentale du comportement thermique et rhéologique d'émulsions de paraffine dans l'eau utilisées comme réfrigérants secondaires

Vasile, Virginia 26 July 2019 (has links)
Une émulsion à changement de phase (PCME: phase-change material emulsion) est un fluide consistant en une émulsion d'un matériau à changement de phase (PCM, phase change material), comme de la paraffine, dispersé dans un fluide porteur (phase continue), souvent de l'eau ou une solution acqueuse de surfactant. Les PCME peuvent être envisagés comme fluides à haute performance thermique (frigoporteurs ou caloporteurs) en raison de leur potentiel de transport de chaleur latente (cristallisation ou fusion du PCM). Cette thèse présente des résultats expérimentaux concernant le comportement thermo-rheologique des differentes versions de PCME (émulsions de paraffine dans différentes solutions acqueuses de surfactant, avec une concentration massique en paraffine égale à 30 %) sur une plage de température de 0 - 20 °C. Les propriétés thermophysiques des émulsions ont été déterminées. Ensuite, une étude expérimentale du transfert de chaleur par convection forcée laminaire a été effectuée. Le coefficient de transfert de chaleur convectif de l'émulsion pendant le refroidissement a été déterminé dans une configuration expérimentale proche de celle pouvant être rencontrée dans des échangeurs thermiques à plaques. La configuration se compose principalement de deux canaux rectangulaires (80 x 6 mm²) de longueurs égale à 1 m. Des corrélations utiles pour évaluer les coefficients d'échange thermique (locaux ou globaux) ont été établies entre les nombres de Nusselt, de Reynolds et de Prandtl. Un banc d'essais spécifique a également été utilisé pour analyser le comportement rhéologique des PCME. Des essais ont été effectués à l'aide d'un viscosimètre à différentes températures. La stabilité des émulsions a été examinée sous diverses charges thermomécaniques. Les expériences ont révélé un comportement rheofluidisant. L'ensemble de ces résultats montre que les PCME sont des candidats prometteurs pour les applications à la climatisation. / A phase change material emulsion (PCME) is a fluid consisting of an emulsion of a phase change material (PCM), such as paraffin, dispersed in a carrier fluid (contiunuous phase), often water of an aqueous solution of surfactant. PCMEs can be considered as potential high performance thermal fluids (used as secondary refrigerants or as heat transport fluids) owing to their latent heat involved in the fusion of cristalisation of the PCM. This thesis reports experimental results concerning the thermo-rheological behavior of different versions of a PCME (30%wt. paraffin concentration in various acqueous solutions of surfactant) over the temperature range [0 – 20 °C]. The thermophysical properties of the PCMEs were determined. Then, an experimental study of forced convection heat transfer during laminar flow was carried out. The convective heat transfer coefficient of the PCMEs during cooling was determined in an experimental configuration mocking up applications in plate heat exchangers. The configuration mainly consists of two 1 m long rectangular channels (80 x 6 mm2). Correlations were developped for the prediction of the (local and overall) heat transfers coefficients, based on the Nussel, Reynolds and Prandtl numbers. A specific test bench was also used to analyse the rheological behaviour of the PCMEs. Tests were carried out using a viscometer at different temperatures. The stability of the emulsion was examined under various thermo-mechanical loads. Experiments revealed a pseudoplastic behavior for all tested versions of the PCME. All these results show that PCMEs are an attractive candidate for their applications in the field of air conditioning.
73

Implementation of socioeconomic criteria in a life cycle sustainability assessment framework applied to housing retrofitting. The Brussels-Capital region case study

Touceda Gomez, Maria Isabel 10 October 2016 (has links) (PDF)
Most of the housing stock in European cities needs to be updated to fulfill current requirements. Although energy and climate have been prioritized in European policies, other sustainable development challenges are sometimes disregarded. Retrofitting plays a part in addressing social concerns such as unemployment and poverty. Therefore, these issues also need to be tackled during the decision-making process.Decision makers need assessment methods to help them to comprehensively address complex processes such as retrofitting on a territorial scale. Several tools are available to address certain aspects of building sustainability, but these often disregard social inclusion aspects. The life cycle sustainability assessment (LCSA) methodology seems to be an appropriate framework, but it needs further adaptation and development for the intended application; that is, to guide policy-making related to housing retrofitting in a given territory towards a more sustainable model of development.This PhD thesis develops an assessment tool in the framework of LCSA. The proposal combines environmental assessment methods with a set of specifically developed socioeconomic models. The socioeconomic models address social and socioeconomic concerns, which are relevant in housing retrofitting processes, for which a cause-effect relationship can be established. The so-called characterization models result from the identification, combination and adaptation of available methods developed within various research fields. These methods analyze damages to the health of workers involved in the life cycle and to the health of the household living in the retrofitted dwelling. Impacts on human well-being and dignity are addressed through prosperity, in terms of fair employment, alleviation of fuel poverty of households, and contribution to economic growth.Two retrofits are analyzed and compared in multiple scenarios of household and housing conditions. The impacts of the retrofitting on sustainable development are calculated considering their remaining life period and taking into account the reference situation where retrofitting would not be undertaken. Some of the results are unexpected, whereas others were more predictable, and the tool helps to properly quantifying them. However, the tool does not provide a unique solution: the “best-performing” scenarios regarding natural environment are the “less-performing” scenarios regarding health and well-being, and vice versa. Decisions therefore need to be adjusted and aim for a combination of job creation, meeting environmental targets, overcoming poverty thresholds and using available public resources. This LCSA proposal helps to adapt measures which promote retrofitting to housing typologies, household type and dwelling conditions. This tool also serves to identify scenarios to prioritize and quantify the potential improvements in the retrofitting process. / En Europe, la plupart du parc bâti de logements doit être rénové en accord avec les besoins actuels. Dans les politiques européennes, la priorité est donnée à l’énergie et au climat et d’autres défis liés au développement durable semblent être négligés. La rénovation parait pouvoir atténuer des problèmes sociaux tels que le taux de chômage, la pauvreté ou l’exclusion sociale et doit donc aussi être considérées.Les décideurs publics ont besoin de méthodes d’analyse qui leur permettent d’aborder des processus complexes comme la rénovation de logements au niveau du territoire. Il y plusieurs outils à disposition pour analyser certains aspects de la durabilité des bâtiments mais, souvent, ces outils ne prennent pas en compte des aspects d’inclusion sociale. La méthodologie d’analyse de la durabilité du cycle de vie (LCSA en anglais) s’avère un cadre approprié pour aborder cette problématique mais il est encore nécessaire de la développer et de l’adapter pour l’appliquer à l’objet de cette étude ,c’est-à-dire, guider la prise de décisions publiques, en relation avec la rénovation de bâtiments à l’échelle du territoire, vers un développement plus durable.Cette recherche développe « sur mesure » un outil d’analyse dans le cadre du LCSA. La méthodologie proposée combine des méthodes d’analyse environnementale avec un ensemble de modèles socioéconomiques, dits modèles de caractérisation. Ces derniers, spécifiquement développés, ciblent des préoccupations sociales et socioéconomiques qui concernent le processus de rénovation du logement et dont la relation cause-effet peut être établie. Ils résultent de l’identification, la combinaison et l’adaptation de méthodes existantes développées dans différents domaines. Ces méthodes analysent les impacts sur la santé des travailleurs impliqués dans tout le cycle de vie et sur la santé du ménage qui habite le logement. Les impacts sur le bien-être et la dignité humaine sont analysés au moyen de la prospérité, en termes de travail juste, de la lutte contre la précarité énergétique et de la contribution au développement économique.Les effets produits par deux rénovations à Bruxelles sont analysés et comparés dans plusieurs scénarios, pour la période de vie qui reste au logement. Quelques résultats s’écartent de ceux attendus ;d’autres pouvaient être pressentis mais cet outil permet de les quantifier de manière appropriée. Cependant, l’outil ne dégage pas de solution unique :dans certains cas, les bénéfices en termes de bien-être sont moindres pour les scénarios où la rénovation produit les meilleurs résultats environnementaux, et vice versa. Les décisions résultent de l’ajustement et la combinaison entre les objectifs en termes d’environnement, de création d’emploi, seuils de seuil de pauvreté et les ressources publiques disponibles. Cet outil aide à l’adaptation des politiques et mesures d’encouragement aux typologies de bâti, aux types de ménages et aux conditions du logement. Il permet l’identification de scénarios à rendre prioritaire, ainsi que de quantifier les effets d’éventuelles améliorations à apporter au processus de rénovation urbaine. / Doctorat en Art de bâtir et urbanisme (Polytechnique) / info:eu-repo/semantics/nonPublished
74

Contribution à l'évaluation in situ des performances d'isolation thermique de l'enveloppe des bâtiments / In situ assessment of the thermal insulation performance of building envelopes

Thébault, Simon Romain 27 January 2017 (has links)
Dans un contexte d’économie d’énergie et de réduction des émissions de gaz à effet de serre, de nombreux efforts ont été réalisés en France pour renforcer l’isolation de l’enveloppe des bâtiments afin de contribuer à réduire les consommations de chauffage. Toutefois, il arrive souvent que la performance thermique calculée avant construction ou rénovation ne soit pas atteinte sur le terrain (erreur de calcul, défauts de mise en œuvre, etc.). Or, pour pouvoir généraliser la construction de bâtiments à basse consommation et la rénovation, il faut pouvoir garantir aux maîtres d'ouvrage une performance réelle de leur bâtiment après travaux. Le fait de mesurer in situ la performance intrinsèque d'isolation thermique de l'enveloppe permet de contribuer à cette garantie. Il existe à l’échelle internationale de nombreuses méthodes basées sur le suivi des consommations et des conditions thermiques intérieures et extérieures. Certaines ont déjà fait leurs preuves sur le terrain, mais sont souvent soit contraignantes, soit peu précises. Et surtout, les calculs d’incertitude associés sont souvent rudimentaires. L’objectif de ce travail financé par le CSTB est de consolider scientifiquement une nouvelle méthode de mesure de la qualité d’isolation globale d’un bâtiment à réception des travaux (méthode ISABELE). Dans le premier chapitre, un état de l'art sur les méthodes existantes a été réalisé afin de dégager des pistes d'amélioration sur la base d'une synthèse comparative. La piste prioritaire identifiée porte sur le calcul d'incertitude (un point central du problème). La propagation des erreurs aléatoires par un approche bayésienne ainsi que des erreurs systématiques par une approche plus classique feront l'objet de la méthodologie globale proposée dans le second chapitre. L'une des importantes sources d'incertitude porte sur l'évaluation du débit d'infiltration. La caractérisation de cette incertitude et de l'impact sur le résultat de mesure fera l'objet du troisième chapitre, avec un comparatif de différentes approches expérimentales (règle du pouce, modèles aérauliques, gaz traceur). Enfin, une amélioration de la prise en compte de la dynamique thermique du bâtiment au cours du test sera proposée dans le dernier chapitre. Son fondement repose sur l'adaptation du modèle thermique inverse en fonction du bâtiment et des conditions du test. Pour cela, une sélection parmi une banque de modèles simplifiés est réalisée sur la base de critères statistiques et du principe de parcimonie. Ces différentes dispositions ont été testés sur une large série de mesures menées sur un même bâtiment à ossature bois (chalet OPTIMOB). La robustesse et la précision du résultat de mesure ont ainsi pu être légèrement améliorées. La méthode de calcul du débit d'infiltration, ni trop simple ni trop complexe, a pu également être validée. Enfin, le temps de mesure minimal nécessaire a pu être déterminé en fonction de la classe d'inertie du bâtiment. / The global context of energy savings and greenhouse gases emissions control led to significant efforts in France to boost the thermal insulation in buildings in order to reduce heating consumption. Nevertheless, the stated thermal performance before construction or refurbishment is rarely achieved in practice, for many reasons (calculation errors, defects in materials or workmanship, etc.). Yet, guaranteeing the real thermal performance of buildings on the spot is crucial to enhance the refurbishment market and the construction of energy efficient buildings. To do so, measurement techniques of the intrinsinc thermal insulation performance indicators are needed. Such techniques already exist worldwide, and consist in processing the measurement data from the indoor and outdoor thermal conditions and the heat consumption. Some of them have already proved themselves in the field, but are either binding or very imprecise. And above all, the related uncertainty calculations are often rough. The objective of this thesis funded by CSTB is to consolidate a novel measurement method of the thermal insulation quality of a whole building after reception of work (ISABELE method). In the first chapter, a state of the art of the existing methods allows to identify possible ways to pursue this goal from a comparative synthesis. The primary reflection is about the uncertainty calculation method (which is a central issue). The second chapter presents a global methodology to combine the propagation of random and systematic errors from bayesian and classical approaches. One of the most important uncertainty sources deals with the infiltration air flow evaluation during the test. The third chapter investigates the characterization of this uncertainty, as well as its impact on the final result, depending on the chosen experimental approach (rule of thumb, simplified aeraulic models, tracer gases). Lastly, an improvement of the inclusion of the bluiding thermal dynamics during the test will be proposed in the last chapter. The basis of this improvement is to adapt the inverse model according to the building type and the test conditions. To do so, the proposed algorithm selects a model form a variety of simplified greybox models based on statistical criteria and parcimony. All these contributions have been tested on a large serie of measurements on a same timber-framed building (OPTIMOB shed). The robustness and precision of the results have been slightly improved. The intial infiltration air flow calculation, neither too simple of too complicated, has also been validated. Finaly, a better ordrer of magnitude of the minimal test duration has been determined, depending on the building inertia.
75

Application des représentations diffusives à temps discret

Dauphin, Gabriel 20 December 2001 (has links) (PDF)
Ce travail s'inscrit dans une thématique de recherche sur l'étude des opérateurs pseudo-différentiels sous représentations diffusives ; l'intégration fractionnaire est un exemple devenu classique d'opérateurs diffusifs.<br />Le première partie consiste en la mise en place des représentations diffusives à temps discret. Certains filtres non-relationnels, notamment les différences frationnaires, sont une agrégation continue de dynamiques purement amorties. Les représentations diffusives s'appliquent à toutes les discrétisations de l'intégration fractionnaire y compris celles pour lesquelles la fonction de transfert n'est pas connue analytiquement. Les filtres diffusifs peuvent être réalisés par un système de dimension infinie. Cette structure est un cadre adapté à l'approximation par un filtre relationnel, à l'analyse asymptotique aux temps longs et à l'élaboration d'un critère de dissipativité.<br />La deuxième partie consiste à appliquer ces outils pour l'étude des couplages formés de filtres diffusifs et de filtres rationnels positifs. L'application d'un critère de Nyquist prouve la stabilité énergétique. Ces couplages sont en fait la somme d'une partie entière et d'une partie diffusive, ce résultat de décomposition montre que certains couplages sont stables EBSB (entrée-bornée, sortie-bornée). La dissipativité de la réalisation diffusive ainsi que le lemme de Kalman-Yacubovich-Popov montrent notamment la stabilité interne de ces couplages ; une démonstration originale du caractère asymptotique de la stabilité interne est ainsi proposée. Les approches utilisées pour prouver ces stabiblités permettent une analyse asymptotique aux temps longs.
76

Modèles de connaissance à paramètres identifiables expérimentalement pour les systèmes de refroidissement dessiccatif couplés à un système solaire

Ghazal, Roula 12 April 2013 (has links) (PDF)
La Centrale de traitement d'Air par Dessiccation (CAD) offre un contrôle complet de la température et de l'humidité dans les locaux climatisés. Son élément clé est la roue dessicante qui permet la dessiccation de l'air et une régénération continue. A travers cette étude, nous nous intéressons au développement d'une méthodologie pour obtenir un modèle dynamique de la roue utilisable dans les algorithmes de contrôle avancés de la CAD. La roue dessicante peut être considérée comme un système de type multi-entrées/multi-sorties (MIMO). La seconde partie de ce mémoire concerne l'identification expérimentale des paramètres des modèles d'état de la roue dessicante pour deux types de modèles : boîte noire et boîte grise. Dans le cas de la boîte noire, tous les paramètres du modèle sont identifiés expérimentalement. Dans le cas de la boîte grise, certains paramètres sont dérivés de considérations physiques et les paramètres restants sont identifiés en utilisant les mesures expérimentales des entrées et des sorties. Les paramètres du modèle boîte grise ont une signification physique. En comparaison avec les modèles boîte noire, les modèles boîte grises sont moins précis sur le domaine sur lequel les paramètres ont été identifiés, mais beaucoup plus précis en dehors de ce domaine. Comme les paramètres ont une signification physique, leurs valeurs ne varient pas de manière significative avec le point de fonctionnement utilisé pour l'identification. Dans l'approche boîte grise, les valeurs des paramètres obtenues pour les modèles linéaires sont presque identiques pour tous les modèles locaux du coté dessiccation et pour tous les modèles locaux du coté régénération ; cela nous a permis de considérer qu'un modèle local est valable pour tout le domaine de variation des variables d'entrée. Le modèle final de la roue dessicante se compose de deux modèles globaux : un pour le côté de la dessiccation et l'autre pour le côté de la régénération. La troisième partie de ce travail consiste dans l'identification des coefficients de transfert de masse et de chaleur au sein de la roue dessicante en utilisant un modèle boîte grise. Le coefficient de transfert de masse, le coefficient de transfert convectif et le nombre de Nusselt ont été obtenus en écrivant les paramètres du modèle d'état en fonction d'une seule variable et en exprimant les paramètres en fonction des caractéristiques géométriques et des propriétés de matériaux de la roue. Ce travail contribue au développement d'un modèle d'état utilisable pour la synthèse des algorithmes de contrôle pour la roue dessicante.
77

Rayonnement acoustique d'une structure périodique de type batterie à ailettes : Application aux pompes à chaleur

Gosse, Guillaume 20 November 2012 (has links) (PDF)
La prédiction du bruit émis par les unités extérieures des pompes à chaleur, provenant en partie des batteries à ailettes, constitue un enjeu industriel important. L'obstacle majeur réside dans l'impossibilité de réaliser le calcul acoustique d'une batterie à ailettes avec les outils de simulation classiques (Éléments Finis de Frontière) à cause du trop grand nombre d'éléments nécessaires (près de 600 ailettes par mètre). Cette thèse a pour objectif d'exploiter la périodicité des batteries à ailettes afin de pouvoir calculer leur bruit rayonné à partir du rayonnement d'une seule ailette. La propagation des vibrations est décrite sous la forme d'une décomposition en ondes, autorisant la réalisation séparée des calculs pour chaque onde. Le déplacement en tout point de la structure est calculé à partir du déplacement d'un seul élément unitaire, obtenu par la Méthode des Éléments Finis (FEM). Un élément unitaire acoustique est spécialement défini, comprenant des baffles rigides destinés à représenter l'influence des autres ailettes de la structure. Le rayonnement de cet élément est calculé pour chaque onde en utilisant la méthode des Éléments Finis de Frontière (BEM), puis dupliqué spatialement en tenant compte de la nature propagative des différentes ondes. Pour chaque structure étudiée, la comparaison avec le calcul direct de la structure complète montre une très bonne concordance avec des temps de calcul fortement réduits. L'influence de plusieurs paramètres sur le comportement de la structure a également été identifiée, mettant ainsi en évidence certains phénomènes particuliers propres aux structures périodiques. Dans la dernière partie de cette thèse, une validation expérimentale de l'approche périodique est proposée. Les résultats numériques sont comparables aux mesures vibratoires et acoustiques réalisées sur les batteries à ailettes.
78

Modélisation, conception et étude expérimentale d'une pompe à chaleur industrielle à eau à haute température

Chamoun, Marwan 11 December 2012 (has links) (PDF)
Le contexte énergétique global impose, durablement aux industriels la poursuite des efforts en matière d'efficacité énergétique nécessitant le déploiement de nouveaux procédés innovants éco-efficaces. Une meilleure gestion de l'énergie permet l'amélioration de l'efficacité énergétique globale des procédés ainsi que la réduction des émissions de CO2. Dans ces conditions, la récupération et la valorisation de la chaleur perdue apparait comme un potentiel pour atteindre ces objectifs. L'intégration d'une pompe à chaleur à haute température permet une valorisation de pertes calorifiques en satisfaisant des besoins de chauffage à haute température (>130°C) qui apparaissent simultanément dans certains procédés (distillation, séchage...). Malheureusement, les pompes à chaleur répondant à ces besoins industriels sont indisponibles actuellement. C'est dans ce contexte que s'inscrit la présente étude qui a permis le développement et la mise en place d'une pompe à chaleur à haute température utilisant l'eau comme fluide frigorigène. Les verrous techniques et technologiques limitant la faisabilité d'une telle machine ont été levés en concevant une nouvelle architecture de PAC et en développant deux types de compresseur : un compresseur bi-vis adapté et un compresseur centrifuge bi-étagé à paliers magnétiques. La mise en place de cette PAC munie du compresseur bi-vis est présentée. Un modèle dynamique de cette pompe à chaleur est développé avec Modelica en tenant compte de la présence de gaz incondensables dans la machine. Des modèles détaillés des compresseurs sont développés en fonction de leurs caractéristiques géométriques. Une étude expérimentale de la phase de démarrage est présentée montrant le processus de purge des incondensables et l'évolution de certains paramètres de la pompe à chaleur. Ces résultats expérimentaux ont été confrontés à des simulations numériques. Plusieurs modes de fonctionnement de la machine de récupération des pertes calorifiques sont simulés numériquement et analysés énergétiquement ainsi qu'exergétiquement. Le modèle de pompe à chaleur a enfin été intégré à un modèle de colonne à distiller montrant les économies d'énergie globales et les avantages environnementaux obtenus.
79

Intégration des systèmes à absorption solaire de petites puissances aux bâtiments - approche multifonction solaire : chauffage, ECS et rafraîchissement

Jabbour, Noël 30 September 2011 (has links) (PDF)
L'introduction des nouvelles machines frigorifiques à absorption des petites puissances ouvre des nouvelles perspectives pour les systèmes solaires multifonction multi-source (SYSMFS) qui exploitent le potentiel de l'énergie solaire pour le chauffage, le refroidissement et la préparation de l'eau chaude sanitaire (ECS). Les systèmes solaires combinés (SSC), qui ont précédés les SYSMFS, manquaient néanmoins une procédure adaptée pour le dimensionnement de leurs composants principaux : le panneau solaire et le ballon solaire de stockage thermique. De point de vue de l'énergie et du coût d'investissement et d'exploitation, une méthode de dimensionnement basée sur le pic de charge ne conviendrait pas si la source d'énergie n'est pas garantie d'être stable dans le temps. Une optimisation des composants principaux par la simulation peut être alors une solution clef pour le dimensionnement optimal de SYSMFS. À partir des informations sur les SSC trouvées dans la littérature et celles de fabricant de la machine frigorifique, un schéma hydraulique initial a été élaboré pour un SYSMFS. La modélisation de ce schéma est complexe car des simulations et des modifications répétitives ont été nécessaires pour éliminer les problèmes potentiels de convergence de la solution. A partir de cette expérience, une méthodologie de conception assistée par simulation a été élaborée afin d'en profiter pour des modélisations similaires. En tant que telle, le modèle devrait être prêt pour la phase l'optimisation. Une étude paramétrique a été menée sur le modèle SYSMFS ; elle offre les donnés requises pour la comparaison des algorithmes d'optimisation qui sont testés par la suite. Le résultat de cette étude est une surface de réponse qui représente le coût du SYSMFS en fonction de la superficie du panneau solaire et du volume de stockage thermique du ballon solaire. Pour réduire le nombre des simulations requis par une étude paramétrique complète, l'utilisation d'un algorithme d'optimisation est nécessaire. Un algorithme basé sur le plan d'expérience (OptDOE) a été développé et sa performance est comparée avec celles d'un algorithme d'optimisation hybride sur une fonction de référence de Rosenbrock et sur le modèle SYSMFS. Comparé à l'algorithme hybride, OptDOE a montré une bonne performance. Le nombre de simulations est réduit et les valeurs optimales trouvées, par cette méthode, sont porches de celles de l'étude paramétrique L'OptDOE permet également de décrire le comportement du modèle SYSMFS au voisinage de l'optimum avec une fonction coût approximée. Cette information est importante surtout au cas où la fonction coût a la forme d'une vallée. Dans ce cas, des valeurs différentes de l'optimum donnent presque le même coût global.
80

Influence des transferts hygro-aérauliques sur les transferts thermiques dans les super-isolants nanostructurés sous vide

Bouquerel, Mathias 13 December 2012 (has links) (PDF)
Les panneaux d'isolation sous vide (PIV) sont constitués d'un matériau de coeur nanoporeux en dépression, et d'une enveloppe barrière aux gaz atmosphériques. Leur conductivité thermique initiale est de l'ordre de 5 mW/(m.K), cinq à huit fois inférieure à celle des isolants conventionnels. Au regard des isolants classiques, le questionnement le plus important concerne le couple performance / durabilité. La réponse passe par la compréhension et la modélisation des transferts thermiques et massiques dans les PIV. De nombreuses études expérimentales et numériques ont conduit à un modèle semi-empirique pour la conductivité thermique apparente d'un PIV, prenant en compte les différents modes de transfert dans le panneau. Ce modèle met en lumière le principal mécanisme de vieillissement : du fait de la perméation gazeuse à travers l'enveloppe, pression et humidité dans le panneau remontent au cours du temps, ce qui engendre une augmentation de la conductivité thermique. L'étude des transferts massiques à travers l'enveloppe est particulièrement délicate. Premièrement, la modélisation de la perméabilité des enveloppes utilisées (membranes multicouches de films polymères métallisés) repose sur la prise en compte des micro-défauts dans les couches métallisées, qui gouvernent le débit total de perméation. Deuxièmement, les valeurs des perméabilités à mesurer sont trop basses pour beaucoup de techniques conventionnelles. Troisièmement, une analyse de la littérature montre une lacune de taille en ce qui concerne la prise en compte de l'influence conjointe de la température et de l'humidité relative dans le modèle classique de perméation gazeuse. En se basant sur des données expérimentales existantes, le rôle de l'humidité relative sur les propriétés barrières des enveloppes des PIV est mis en lumière. L'existence d'un couplage entre les flux des différents gaz est posé comme hypothèse de départ à la mise en place d'un nouveau modèle de perméation gazeuse, prenant en compte pression partielle et pression totale, et donc la concentration molaire de chaque gaz dans le mélange. Les prédictions de ce modèle sont comparées à celles issues du modèle classique de perméation gazeuse, et les différences de comportement entre les deux modèles sont mises en avant. Deux séries de mesure de perméance sont ensuite mises en place, par vieillissement de PIV en enceintes climatiques et par mesure directe de perméance sur échantillons de membrane (méthode manométrique). Ces mesures sont menées à température et humidité relative fixées (T = 48 °C, φ = 65 % HR), mais avec une pression totale variant de 80 mbar à 1 bar. Cette campagne de mesure exploratoire ne montre pas d'influence notable de la pression totale sur la perméabilité à la vapeur d'eau. Ces résultats permettent de dresser les premières conclusions sur le rôle respectif de la pression partielle et de la pression totale, et de proposer une suite à la démarche expérimentale initiée dans cette étude.

Page generated in 0.0835 seconds