• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 102
  • 50
  • 28
  • 16
  • 11
  • 9
  • 7
  • 5
  • 5
  • 1
  • 1
  • 1
  • Tagged with
  • 264
  • 175
  • 66
  • 63
  • 55
  • 51
  • 39
  • 37
  • 36
  • 24
  • 21
  • 21
  • 20
  • 19
  • 18
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
141

Comparaison entre l'infiltration para-vertébrale rétrolaminaire d'un mélange analgésique non-stéroïde et l'infiltration péridurale stéroïdienne chez les patients souffrant de douleurs radiculaires chroniques : une étude rétrospective

Nekoui, Alireza 06 1900 (has links)
No description available.
142

Desenvolvimento de diferentes métodos LC-MS/MS para a determinação de fármacos e endocanabinóides em amostras de plasma / Development of different LC-MS/MS methods for the determination of drugs and endocannabinoids in plasma samples

Acquaro Junior, Vinicius Ricardo 06 April 2018 (has links)
Esta tese foi dividida em três capítulos. O capítulo I descreve o desenvolvimento do método Column switching UHPLC-MS/MS para a determinação simultaneamente de fármacos psicotrópicos em amostras de plasma de pacientes esquizofrênicos. A politerapia é uma prática comum no tratamento da esquizofrenia. Portanto, a monitorização terapêutica destes fármacos tem sido realizada para o ajuste das doses e individualização da terapia farmacológica. O método Column switching UHPLC-MS/MS apresentou linearidade na faixa de concentração de 0,025 a 1,25 ng mL-1 com R2 acima de 0,9950 e a falta de teste de ajuste (p > 0,05); precisão com coeficientes de variação inferiores a 12% e exatidão com erro padrão relativo inferior a 14%. Este método foi aplicado com sucesso para determinação de fármacos em amostras de plasma de pacientes esquizofrênicos para fins de monitorização terapêutica. No capítulo II, o desempenho cromatográfico de colunas C18 superficialmente e totalmente porosas com diferentes tamanhos de partícula foi avaliado para a análise de fármacos psicotrópicos por LC-MS/MS e LC-DAD. Com o sistema LC-MS/MS foram avaliados os seguintes parâmetros cromatográficos: altura do prato reduzido vs velocidade linear reduzida, impedância vs velocidade linear reduzida, tempo da corrida cromatográfica vs vazão, pressão vs vazão, resolução, capacidade de pico, assimetria e fator de retenção. Já com o sistema LC-DAD foram avaliados a hidrofobicidade, atividade silanol e impurezas metálicas também foram avaliadas. As colunas com superfície carregada apresentaram maior eficiência cromatográfica para os fármacos em sua forma ionizada. Já as colunas com partículas menores que 2 µm (Cortecs 1,6 µm, Acquity 1,7 µm, e Kinetex 1,7 µm) apresentaram maior eficiência cromatográfica para os fármacos na forma parcialmente ionizada. Os modelos matemáticos gerados foram capazes de prever a pressão e o tempo da corrida cromatográfica em diferentes vazões para todas as colunas. Considerando a eficiência, impedância, resolução, capacidade de pico, fator de retenção e hidrofobicidade, as colunas Cortecs 1,6 µm e Acquity 1,7 µm apresentaram melhor desempenho durante a análise dos fármacos em amostra de plasma. O capítulo III descreve o desenvolvimento e validação dos métodos SPME-UHPLC-MS/MS e Bio-SPME-Nano-ESI-MS/MS para a determinação dos endocanabinóides (AEA e 2-AG) em amostras biológicas. Para a otimização do processo SPME foram avaliadas as fases SPME (C18, C30 e HLB) e os solventes para dessorção (metanol, acetonitrila e isopropanol). Os aditivos modificadores de matriz, como cloridrato de guanidina, ácido trifluoroacético e acetonitrila foram avaliados por planejamento experimental. Os métodos SPME-UHPLC-MS/MS e Bio-SPME-Nano-ESI-MS/MS, com a fase HLB biocompatível, apresentaram para ambos endocanabinóides valores de LOQs de 1 ng mL-1 e 50 ng mL-1, respectivamente. O método Bio-SPME-Nano-ESI-MS/MS permitiu o direto acoplamento da fibra SPME ao espectrômetro de massas via dessorção/ionização nanoeletrospray que resultou em rápida determinação quantitativa dos endocanabinóides em amostras biológicas. / This thesis is divided into three chapters. Chapter I describes the development of a column switching UHPLCMS/MS method to determine psychotropic drugs in schizophrenic patients plasma samples simultaneously. Polytherapy is a common practice in schizophrenia treatment. Therefore, therapeutic drug monitoring has been applied to adjust doses and to customize pharmacological therapy. The column switching UHPLCMS/MS method developed here is linear at concentrations ranging from 0.025 to 1.25 ng mL-1 with R2 above 0.9950 and presents lack of fit test (p > 0.05), precision with coefficients of variation lower than 12%, and accuracy with relative standard error lower than 14%. This method was successfully applied to determine drugs in schizophrenic patients plasma samples for therapeutic drug monitoring. In chapter II, the chromatographic performance of C18 superficially porous columns and of C18 fully porous columns with different particle sizes were evaluated for analysis of psychotropic drugs by LC-MS/MS and LC-DAD. Within the LC-MS/MS system, the following chromatographic parameters were assessed: reduced plate height vs reduced linear velocity, impedance vs reduced linear velocity, chromatographic run time vs flow rate, backpressure vs flow rate, resolution, peak capacity, asymmetry, and retention factor. Within the LC-DAD system, hydrophobicity, silanol activity, and metal impurities were also examined. Columns with charged surface displayed improved chromatographic efficiency for drugs in the ionized form. Columns with particles smaller than 2 µm (Cortecs 1.6 µm, Acquity 1.7 µm, and Kinetex 1.7 µm) presented higher chromatographic efficiency for the drugs, which were in their partially ionized form. The generated mathematical models were able to predict the backpressure and the chromatographic run time at different flow rates for all the columns. Considering efficiency, impedance, resolution, peak capacity, retention factor, and hydrophobicity, columns Cortecs 1.6 µm and Acquity 1.7 µm provided the best performance during analysis of drugs in plasma samples. Chapter III describes the development and validation of the SPME-UHPLC-MS/MS and the Bio-SPME-Nano-ESI-MS/MS methods for determination of endocannabinoids (AEA and 2-AG) in biological samples. To optimize the SPME process, SPME coatings (C18, C30, and HLB) and solvents for desorption (methanol, acetonitrile, and isopropanol) were evaluated. Matrix modifier additives, such as guanidine hydrochloride, trifluoroacetic acid, and acetonitrile, were assessed by experimental design. The SPME-UHPC-MS/MS and the Bio-SPME-Nano-ESI-MS/MS methods with HLB biocompatible coating provided LOQ values of 1 ng mL-1 and 50 ng mL-1, respectively, for both endocannabinoids. The Bio-SPME-Nano-ESI-MS/MS method allowed direct coupling of SPME fibers to the mass spectrometer by desorption/ionization nanoelectrospray, which resulted in rapid quantitative determinations of endocannabinoids in biological samples.
143

RAFT-Polymerisation an Oberflächen / RAFT Polymerization from Surfaces

Nguyen, Duc Hung 03 July 2007 (has links)
No description available.
144

Management of ergonomic aspects in early design phases using virtual reality : Mapping of ergonomic aspects in early design phases, How would mordern technology like VR be used? / Hantering av ergonomiska aspekter i tidigt konstruktonsfas genom använding av skenbar verklighet : Kartläggning av ergonomiska aspekter i tidiga konstruktionsfaser, Hur skulle modern teknik som skenbar verklighet användas?

Niemand, Ponthus, Saladdin, Aya January 2018 (has links)
Volvo Group är ett av världens ledande tillverkare av bland annat lastbilar, bussar, entreprenadmaskiner och motorer för marina och industriella applikationer. Volvo Group äger totalt 10 olika märken, dessa är: Volvo Trucks, UD Trucks, Renault Trucks, Mack Trucks, Group Trucks Asia & JVs, Volvo Construction Equipment, Volvo Bus, Volvo Penta, Volvo Financial Services och Governmental Sales. Initiativet till projektet togs av Metod och Processutvecklings avdelningen på Volvo Group Trucks Operations (GTO), som är den delen av Volvo Group som utför själva sammansättningen av lastbilar. Volvo GTO finns i flertal olika länder världen över vilket leder till att arbetsprocesserna kan skilja mellan länderna. För att kunna standardisera ett arbetssätt där konstruktören (komponent ägaren) tillsammans med geometri arkitekten kan göra en första ergonomisk analys på den berörda komponenten. För att detta ska vara möjligt så tog projektet fram en handbok på hur man som komponentägare skall gå tillväga för att få en så bra och korrekt analys som möjligt. I denna kandidatarbete tas det upp förslag på hur VR hade kunnat hjälpa till ett utvärderingsverktyg redan i konstruktionsstadiet när en ny produkt/komponent ska tas fram eller om det ska göras förbättringar på en befintlig komponent. Kandidatarbetet har valt att fokusera mest på hur konstruktören och geometri arkitekten ska kunna utvärdera de ergonomiska aspekterna med VR som hjälp. Projektet har undersökt två user case varav ett av dem presenteras i denna rapport. Detta gäller monteringen av värmeskydd. Anledningen till att just denna montering valdes är på grund av dess dåliga ergonomi och åtkomlighet. Projektet valde att göra både en RULA-analys och PLIBEL-analys. RULA-analysen gav hög totalpoäng, 7 av 7 medan PLIBEL endast är en analys på arbetsplatsen vilket gav ett bra underlag för fortsatt arbete. Studien visade att VR är ett väldigt bra hjälpmedel vid analys av ergonomiska aspekter i tidig design fas. Det ger relevanta resultat och har potential för besparingar i resurser och kostnader inom utvecklingsprocessen. För att förbättra kandidatarbetes resultat har det gjorts besök på ESI-Group som har gått in med stöttning i form av VR utrustning och workshop. Detta gav projektmedlemmarna en inblick på möjligheterna man har med VR. / Volvo Group is one of the Worlds leading manufacturer in the categories trucks, busses, construction equipment and engines for the marine and industrial applications. Volvo Group consist of many different brands 10 in total, these are: Volvo Trucks, UD Trucks, Renault Trucks, Mack Trucks, Group Trucks Asia & JVs, Volvo Construction Equipment, Volvo Bus, Volvo Penta, Volvo Financial Services and Governmental Sales. The initiative for the project came from Method and Process Development within Volvo Trucks Tuve Plant, department at Volvo Group Trucks Operations (GTO), which is the part of Volvo Group performing the actual production of the trucks. Volvo GTO is located worldwide in several different countries, which leads to different work processes. To standardize a method where the designer (component owner) together with the geometry architect can make a first ergonomics analysis of the concerned component. To make this possible, the project presented a manual on how the component owner should proceed to obtain as good and correct analysis of ergonomics as possible. This bachelor thesis makes suggestions for how VR would be helpful in the design phase as an evaluation tool during development of a new product/component or whether improvements should be made to an existing component. The thesis has focused mostly on how the designer and geometry architect can evaluate the ergonomics aspects with VR as a help, already in the design phase. The project has investigated two user cases. One of them is presented in this report. This applies to the installation of heat shield, the reason that this particular assembly was chosen is due to its poor ergonomics and accessibility. The project chose to do a RULA-analysis and PLIBEL-analysis. The RULA analysis gave a high total score, 7 out of 7, while PLIBEL was an analysis at the workplace. Both proved to be a good basis for continued work.  The study shows that VR is a great tool for analysis of the ergonomics aspects in early design phase. It gives relevant results and has the potential for savings in resources and cost in product development process. To improve the results of the thesis, there have been visits on ESI-Group which has sponsored the thesis in the form of VR equipment and workshop. This gave the project members an insight into the possibilities of VR.
145

Contribution à l'étude phytochimique d'orchidées tropicales : identification des constituants d'Aerides rosea et d'Acampe rigida : techniques analytiques et préparatives appliquées à Vanda coerulea et Vanda teres / Contribution to the phytochemical studies of tropical orchids

Čáková, Veronika 16 December 2013 (has links)
L’analyse de la composition chimique de deux orchidées de la sous-tribu des Aeridinae, Aerides rosea Lodd. ex. Lindl. & Paxton et Acampe rigida (Buch.-Ham. ex Sm.) P. F. Hunt, a été menée en ayant recours à des techniques de couplages et grâce à une stratégie de déréplication. Dix dérivés phénanthréniques ont ainsi été identifiés dans les tiges d’A. rosea, dont deux nouvellement décrits. Quatre stilbénoïdes, trois dérivés d'acides phénoliques et quatre esters d'acide cinnamique ont été identifiés dans les tiges d’A. rigida. Nous avons également effectué des dosages de traceurs dans différents échantillons de deux représentants de la tribu des Vandeae : Vanda teres (Roxb.) Lindl. et Vanda coerulea Griff. ex. Lindl., afin de mettre en évidence d’éventuelles variations de composition en fonction des facteurs environnementaux et du stade de croissance végétative. Enfin, nous avons mis au point des conditions d’isolement préparatif par chromatographie de partage centrifuge afin de purifier des marqueurs biologiques préalablement identifiés dans les tiges de Vanda teres : trois glucospyranosyloxybenzyl - malates ainsi que leur précurseur biosynthétique. / Phytochemical analyses of the composition of two orchids Aeridinae subtribe, Aerides rosea Lod . ex . Lindl . & Paxton and Acampe rigida (Buch. -Ham . Ex Sm.) P. F. Hunt were conducted using the state-of-the-art hyphenated techniques and a developed dereplication strategy. Ten phenanthrene derivatives have been identified in the stems of A. rosea, including two newly described structures. Four stilbenoids, three phenolic acids derivatives and four cinnamic acid esters were identified in the stems of A. rigida. We also performed quantitative assays of chemical tracers in different samples of two representative species from the Vandeae tribe: Vanda teres (Roxb.) Lindl. and Vanda coerulea Griff. ex. Lindl., in the aim to highlight possible variations in their composition, depending on environmental factors and vegetative growth stage. Finally, we have developed conditions for preparative isolation using centrifugal partition chromatography to purify biomarkers previously identified in the stems of Vanda teres: three glucosyloxybenzyl malates derivatives and their biosynthetic precursor.
146

La conception collaborative avec les fournisseurs : proposition d'une méthode d'analyse par les dysfonctionnements / Measuring benefits of inter organisational collaborations and implementing necessary interface process

Personnier, Hélène 15 October 2013 (has links)
Ce travail de thèse a pour thème le co-développement de nouveau produit avec les fournisseurs.Nous proposons une méthode d’analyse des dysfonctionnements liés à ce type de conceptiondite « collaborative » qui permet d’en améliorer la pratique. Ce travail s’appuie sur des études decas réalisées au sein de l’entreprise Somfy, des interviews menées au sein de 10 entreprises etune étude quantitative menée avec l’Université de Twente. A partir de la littérature et des étudesde cas, nous proposons une liste des dysfonctionnements puis une classification de ces derniersen 5 classes selon le cycle de vie de la collaboration client/fournisseur. Puis, une analysequantitative d’impact des dysfonctionnements sur la performance projet via une enquête estproposée pour généraliser les résultats des études de cas. Le résultat final de cette thèse est unoutil d’analyse de risques en co-développement avec les fournisseurs développé avecl’entreprise Somfy et inspiré de la démarche AMDEC. Cet outil permet, en début de projet de codéveloppement,d’identifier les dysfonctionnements potentiels les plus critiques de façon àmettre en place un plan d’action adapté. / This thesis is focused on collaborative development of new products with suppliers. A method toanalyze failures linked to this type of development is proposed and enables to improve thispractice. This work is based on case studies carried out at Somfy Company, on interviews carriedout with 10 companies and on a quantitative study carried out with the University of Twente.From a literature review and our case studies, a list of failures is proposed followed by a failuresclassification in 5 classes following the customer/supplier collaboration lifecycle. Then, aquantitative impact analysis of the failures on the project performance via a survey is proposedto generalize the case studies’ results. The final result of this thesis is a risk analysis tool appliedto collaborative development with suppliers developed with Somfy and inspired by the FMEAapproach. This tool enables, at the beginning of a collaborative development project, to identifythe most critical potential failures in order to set up an adapted action plan.
147

Aplicações da Espectrometria de Massas de Ressonância Ciclotrônica de Íons por Transformada de Fourier (FT-ICR MS) em Petroleômica

Pereira, Thieres Magaive Costa 23 August 2013 (has links)
Made available in DSpace on 2016-12-23T14:41:52Z (GMT). No. of bitstreams: 1 Thieres Magaive Costa Pereira.pdf: 7173330 bytes, checksum: 5a2aee56b5048351ab0fc838877f8030 (MD5) Previous issue date: 2013-08-23 / O petróleo é uma mistura complexa, sendo uma das misturas mais desafiadoras para as análises químicas. Muitas técnicas são empregadas para a caracterização dos constituintes do óleo. Entretanto, quando combinamos o altíssimo poder de resolução e exatidão da espectrometria de massas, em especial a Ressonância Ciclotrônica de Íons com Transformada de Fourier, (FT-ICR MS) com fontes de ionização a pressão atmosférica, uma atribuição precisa de mais de 20 000 compostos orgânicos do petróleo pode ser obtida. Na indústria do petróleo existe um grande interesse na análise de ácidos naftênicos e asfaltenos devido a problemas como corrosão e formação de depósitos, que aumentam os custos de produção. Portanto este trabalho tem como objetivo a avaliação da termodegradação de ácidos naftênicos, além do emprego das fontes de ESI, APCI, APPI, LDI e MALDI para aquisição de novos dados relativos a caracterização de asfaltenos. Dois petróleos foram utilizados nos ensaios de termodegradação, o petróleo A com acidez de 2,38 mg KOH g-1 e o petróleo B com 4,79 mg KOH g-1 os quais foram tratados a 280, 300 e 350 ºC pelo período de 2, 4 e 6 horas. De uma maneira geral, as principais classes identificadas para ambas às amostras foram O2, N e NO2, respectivamente. Uma leve redução do NAT e da abundância relativa referente à classe O2 foram observado em função da temperatura e do tempo de envelhecimento (T = 280 → 300 oC e t = 2 → 6 h), sendo que a temperatura de tratamento térmico a 350 ºC demonstrou-se determinante na remoção de compostos da classe O2. O perfil químico de amostras de asfaltenos brasileiros foi avaliado utilizando-se cinco diferentes métodos de ionização em ambos os modos de ionização: positivo e negativo, depois, a distribuição de peso molecular, distribuição de classe, parcelas típicas de número de carbono contra DBE e diagramas van Krevelen foram obtidos e discutidos. Um comportamento atípico foi observado para a fonte de LDI e MALDI (±) FT-ICR MS. Um amplo perfil, de m/z 500-3000, apresentando espaçamento de 24 Da foi observado, e este corresponde a formas alotrópicas de fulereno, C60. Em geral, os asfaltenos apresentaram um elevada proporção de espécies heteroatómicas como: HC, HC [H], N, N [H], N2O, N2O [H], N2, N2 [H], O, O[H] para o modo (+) e N, N [H], NO, NO [H], NO, NO2[H], N2O, N2O[H] para o modo negativo. Nos diagramas de DBE contra o número de carbono, os asfaltenos mostraram para cada valor de DBE uma pequena amplitude de compostos com respeito à NC, proporcionando assim, imagens que formam uma linha de 45 ° entre os eixos CN e DBE. Isto indica que estes compostos não exibem grandes cadeias de alquílicas, sendo composta principalmente por anéis aromáticos. Em geral os diagramas de van Krevelen mostraram alta proporção de compostos com razão H/C ~0,7, corroborando com a existência de espécies altamente aromáticas / Petroleum is a complex mixture, being one of the most challenging mixtures for chemical analyzes. Many techniques are employed to characterize constituents of the oil. However , when we combine the highest resolving power and accuracy of mass spectrometry , especially Ion Cyclotron Resonance Fourier Transform ( FT - ICR MS ) with sources of atmospheric pressure ionization , an assignment need more than 20 000 organic compounds in the oil can be obtained. In the oil industry there is a great interest in the analysis of asphaltenes and naphthenic acids due to problems such as corrosion and deposit formation, which increases production costs. Therefore this study aims to evaluate the thermodegradation of naphthenic acids, besides the use of sources of ESI, APCI, APPI, MALDI and LDI for the acquisition of new data on the characterization of asphaltenes . Two test oils were used in thermodegradation of the oil with an acidity of 2.38 mg KOH g -1 and Oil B with 4.79 mg KOH g- 1 which were treated at 280 , 300 and 350 ° C for a period of 2 , 4 and 6 hours. Generally, the major classes identified for both samples O2, NO2, and C, respectively. A slight reduction of NAT and relative abundance refers to the class O2 were observed as a function of temperature and aging time (T = 280 → 300 ° C t = 2 → 6 h), and the heat treatment temperature at 350 ° C showed a determinant for the removal of class O2. The chemical asphaltenes Brazilian samples was evaluated using five different methods of ionization in both modes of ionization: positive and negative, then the molecular weight distribution, distribution class, typical plots versus carbon number and DBE van Krevelen diagrams were obtained and discussed. An unusual behavior was observed for the LDI and MALDI source ( ± ) FT - ICR MS . A comprehensive profile of m / z 500-3000, with spacing of 24 Da was observed, and this corresponds to allotropes of fullerene C60. In general, the asphaltenes had an heteroatómicas high proportion of species such as HC , HC [ H] , N, [ H] , N2O N2O [ H] N2, N2 [ M ] O O [ H] to mode (+) and N, [ H ] , NO [ H] , NO , NO2, [ H] , N2O N2O [ H ] for the negative mode . In the diagrams DBE against the carbon number , the asphaltenes shown for each value of DBE composed of a small amplitude with respect to NC, thus providing images that form a line of 45 ° between the axes CN and DBE. This indicates that these compounds do not exhibit large chain alkyl, composed mainly of aromatic rings. In general diagrams van Krevelen showed a high proportion of compounds ratio H / C ~ 0.7, confirming the existence of highly aromatic species
148

Oleorresina de Copaifera spp.: caracterização, verificação da atividade antimicrobiana in vitro e avaliação preliminar de uma formulação em vacas leiteiras com mastite / Oleoresin of Copaifera spp.:characterization, verification antimicrobial activity in vitro and preliminary evaluation a formulation

Faria, Maria Juíva Marques de 07 May 2014 (has links)
Submitted by Luciana Ferreira (lucgeral@gmail.com) on 2014-12-22T14:31:16Z No. of bitstreams: 1 Dissertação - Maria Juíva Marques de Faria - 2014.pdf: 3781718 bytes, checksum: 5a98e4c3d48dde6e80b58427a1a73012 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2015-01-26T13:13:18Z (GMT) No. of bitstreams: 1 Dissertação - Maria Juíva Marques de Faria - 2014.pdf: 3781718 bytes, checksum: 5a98e4c3d48dde6e80b58427a1a73012 (MD5) / Made available in DSpace on 2015-01-26T13:13:18Z (GMT). No. of bitstreams: 1 Dissertação - Maria Juíva Marques de Faria - 2014.pdf: 3781718 bytes, checksum: 5a98e4c3d48dde6e80b58427a1a73012 (MD5) Previous issue date: 2014-05-07 / Bovine mastitis is an inflammatory/infectious process of the mammary gland, its etiology is complex and multivariate. The most common mastitis has bacterial origin. Because of the high cost to treat this disease, and the bacterial resistance to antibiotics, beyond the losses due to the milk discard or the presence of drug residues in milk, studies are necessary to find out alternative methods to circumvent these problematic. The medicinal plants with antimicrobial activity have been making room in veterinary medicine with the objective to reduce the impact and the use of drugs indiscriminately, as well as maintain the integrity of the animal and control the dissemination of resistant bacterial lineage. Therefore, the aim of this work was characterize the oleoresin Copaifera spp., verify the antimicrobial activity in vitro of oleoresin and essential oil of Copaifera spp. in combating against aerobic and facultative isolated bacteria from cows’ milk with subclinical grade III mastitis diagnostic and evaluate preliminarily, in vivo, phytotherapic formulation composed of Copaifera spp. The tests for characterization of the oleoresin, confirmed its authenticity and quality, considered appropriate for use. The analyzes performed by gas chromatography coupled to mass spectrometry (GC/MS) and electrospray ionization Fourier transformed íonic cyclotron resonance mass spectrometry (ESI FT-ICR MS) identified sesquiterpenes and diterpenes present in the essential oil and oleoresin of Copaifera spp., respectively. The technique of High Performance Liquid Chromatography (HPLC) for sesquiterpenes, especially for β-caryophyllene, can be used in quality control of essential oil and oleoresin of Copaifera spp., as well as in phytotherapic formulation using oleoresin of Copaifera spp. The oleoresin showed better antimicrobial activity than the essential oil of Copaifera spp. (ρ<0,0001) in combating the 55 isolated bacteria. The antibiogram test of the three phytotherapic formulations demonstrated that the oleoresin had antimicrobial activity against the isolated microorganisms. The preliminary evaluation, in vivo, of a phytotherapic formulation containing 20% oleoresin of copaiba was neither effective nor safe, because it intensified the inflammatory process, requiring further tests, such as cytotoxicity and irritability of the raw material plant and of the vehicle used. Key words: Bovine Mastitis. Oleoresin. Essential Oil. Copaifera spp. Minimum Inhibitory Concentration. ESI FT-ICR MS. / Mastite bovina é um processo inflamatório/infeccioso da glândula mamária, de etiologia complexa e multivariada, sendo a de origem bacteriana a mais frequente. Devido aos elevados custos dos tratamentos dessa enfermidade, resistência bacteriana aos antibióticos, além dos prejuízos inerentes ao descarte do leite ou à presença de resíduos de medicamentos no mesmo, faz-se necessário estudos que busquem métodos alternativos para contornar essa problemática. As plantas medicinais com potencial antimicrobiano vêm ganhando espaço na medicina veterinária com o objetivo de reduzir o impacto e o uso de medicamentos de forma indiscriminada, bem como manter a integridade do animal e controlar a disseminação de linhagens bacterianas resistentes. Diante disso, o objetivo desse trabalho foi caracterizar a oleorresina de Copaifera spp., verificar atividade antimicrobiana in vitro da oleorresina e do óleo essencial de Copaifera spp. frente às bactérias aeróbias e facultativas isoladas de leite de vacas diagnosticadas com mastite subclínica grau III e avaliar preliminarmente, in vivo, formulação fitoterápica à base de Copaifera spp. Os testes de caracterização da oleorresina de Copaifera spp. demonstraram sua autenticidade e qualidade, a qual foi considerada adequada para o uso. As análises realizadas por cromatografia gasosa acoplada à espectrometria de massas (CG/EM) e por espectrometria de massas com ionização por electrospray de ressonância ciclotrônica de íons por transformada de Fourier (ESI FT-ICR MS) identificaram os sesquiterpenos e diterpenos presentes no óleo essencial e na oleorresina de Copaifera spp., respectivamente. A técnica Cromatografia Líquida de Alta Eficiência (CLAE) para sesquiterpenos, em especial para β-cariofileno, pode ser utilizada no controle de qualidade de oleorresina e óleo essencial de Copaifera spp., bem como em formulação fitoterápica utilizando oleorresina de Copaifera spp. como matéria-prima vegetal. A oleorresina apresentou melhor atividade antimicrobiana do que o óleo essencial de Copaifera spp. (ρ<0,0001) frente às 55 bactérias isoladas. O teste de antibiograma das três formulações fitoterápicas demonstrou que a oleorresina de copaíba reproduziu a sua atividade antimicrobiana frente aos micro-organismos isolados. A avaliação preliminar, in vivo, de uma formulação fitoterápica contendo 20% oleorresina de copaíba não foi eficaz e nem segura, pois intensificou o processo inflamatório, havendo necessidade de testes futuros, como de citotoxicidade e de irritabilidade dessa matéria-prima vegetal e do veículo utilizado.
149

Estendendo a caracterização dos compostos nitrogenados em resíduo de vácuo por FT-ICR MS / Extending the characterization of nitrogen compounds in vacuum residue by FT-ICR MS

Vasconcelos, Géssica Adriana 10 March 2016 (has links)
Submitted by Cláudia Bueno (claudiamoura18@gmail.com) on 2016-08-17T21:37:32Z No. of bitstreams: 2 Dissertação - Géssica Adriana Vasconcelos - 2016.pdf: 2159448 bytes, checksum: a3e5f1ad74eff4a8b0472438d2a2bbf0 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Cláudia Bueno (claudiamoura18@gmail.com) on 2016-08-17T21:39:28Z (GMT) No. of bitstreams: 2 Dissertação - Géssica Adriana Vasconcelos - 2016.pdf: 2159448 bytes, checksum: a3e5f1ad74eff4a8b0472438d2a2bbf0 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2016-08-17T21:39:28Z (GMT). No. of bitstreams: 2 Dissertação - Géssica Adriana Vasconcelos - 2016.pdf: 2159448 bytes, checksum: a3e5f1ad74eff4a8b0472438d2a2bbf0 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2016-03-10 / Outro / Petroleomics by FT-ICR MS was able to characterize petroleum and its derivatives at molecular level. The most used ionization source on the analysis of these compounds is electrospray. However, species that are more basic or more acidic suppress the ionization of other compounds with less strength. This disadvantage consists of, especially in positive mode, only detecting compounds with higher pKa values preventing the mass spectrometer from reading less basic species that is also present in the sample. In view of this, the development of new methods whose purpose is to minimize these effects is essential. An alternative is to use fast techniques of extraction and separation followed by analysis by FT-ICR MS. This study pursued two goals: first, to perform an extraction of vacuum residue into basic and neutral nitrogen compounds using different methods, and second, to fractionate the basic nitrogen compounds present in RV according to their mass/ratio. Three methods were tested to achieve the first objective: solvent extraction (LLE), column chromatography (LC), and solid phase extraction (SPE). The results showed that LLE was the less selective technique among all three studied procedures. SPE and LC showed similar results, and they allowed to partially separate the basic nitrogen compounds from neutral species. To accomplish the second goal, a fractionation using SPE was applied to the vacuum residue sample. This procedure permitted to detect compounds that apparently were not present in the untreated sample as a consequence of a reduction on ion suppression effect. Electrospray ionization and high resolution mass spectrometry (FT-ICR MS) were employed on the analysis of each sample. / A petroleômica por FT-ICR MS foi capaz de caracterizar o petróleo e seus diferentes derivados a nível molecular. A fonte de ionização mais utilizada na análise destes compostos é o electrospray. Componentes mais básicos e mais ácidos, entretanto, suprimem a ionização de outras espécies com menor força. A grande desvantagem deste fato consiste, especialmente no modo positivo, detectar somente os compostos com elevado pKa impedindo a leitura das espécies menos básicas presentes na mesma amostra. À vista disso, é fundamental o desenvolvimento de novos métodos que tenham por finalidade minimizar estes efeitos. Uma alternativa é fazer o uso de técnicas rápidas de extração e separação seguida pelas análises por FT- ICR MS. Desta forma, este estudo teve dois objetivos principais: primeiro, realizar uma extração dos compostos nitrogenados de resíduo de vácuo em suas frações básica e neutra utilizando diferentes métodos e, segundo realizar um fracionamento dos compostos nitrogenados básicos presentes em RV de acordo com a sua massa. Para se alcançar o primeiro objetivo, três métodos foram testados: Extração líquido-líquido (LLE), cromatografia em coluna clássica (LC) e extração em fase sólida (SPE). Os resultados mostraram que o LLE foi a menos seletiva dentre os três procedimentos estudados. SPE e LC apresentaram resultados semelhantes e foi possível separar parcialmente os compostos básicos das espécies neutras. Para alcançar o segundo objetivo, um fracionamento utilizando extração em fase sólida foi empregado na amostra de resíduo de vácuo. Este procedimento permitiu detectar compostos que aparentemente não estavam presentes na amostra não tratada como consequência da redução do efeito de supressão iônica. A ionização por electrospray e por espectrometria de massa de alta resolução (FT-ICR MS) foram utilizados na análise de cada amostra.
150

Desenvolvimento de diferentes métodos LC-MS/MS para a determinação de fármacos e endocanabinóides em amostras de plasma / Development of different LC-MS/MS methods for the determination of drugs and endocannabinoids in plasma samples

Vinicius Ricardo Acquaro Junior 06 April 2018 (has links)
Esta tese foi dividida em três capítulos. O capítulo I descreve o desenvolvimento do método Column switching UHPLC-MS/MS para a determinação simultaneamente de fármacos psicotrópicos em amostras de plasma de pacientes esquizofrênicos. A politerapia é uma prática comum no tratamento da esquizofrenia. Portanto, a monitorização terapêutica destes fármacos tem sido realizada para o ajuste das doses e individualização da terapia farmacológica. O método Column switching UHPLC-MS/MS apresentou linearidade na faixa de concentração de 0,025 a 1,25 ng mL-1 com R2 acima de 0,9950 e a falta de teste de ajuste (p > 0,05); precisão com coeficientes de variação inferiores a 12% e exatidão com erro padrão relativo inferior a 14%. Este método foi aplicado com sucesso para determinação de fármacos em amostras de plasma de pacientes esquizofrênicos para fins de monitorização terapêutica. No capítulo II, o desempenho cromatográfico de colunas C18 superficialmente e totalmente porosas com diferentes tamanhos de partícula foi avaliado para a análise de fármacos psicotrópicos por LC-MS/MS e LC-DAD. Com o sistema LC-MS/MS foram avaliados os seguintes parâmetros cromatográficos: altura do prato reduzido vs velocidade linear reduzida, impedância vs velocidade linear reduzida, tempo da corrida cromatográfica vs vazão, pressão vs vazão, resolução, capacidade de pico, assimetria e fator de retenção. Já com o sistema LC-DAD foram avaliados a hidrofobicidade, atividade silanol e impurezas metálicas também foram avaliadas. As colunas com superfície carregada apresentaram maior eficiência cromatográfica para os fármacos em sua forma ionizada. Já as colunas com partículas menores que 2 µm (Cortecs 1,6 µm, Acquity 1,7 µm, e Kinetex 1,7 µm) apresentaram maior eficiência cromatográfica para os fármacos na forma parcialmente ionizada. Os modelos matemáticos gerados foram capazes de prever a pressão e o tempo da corrida cromatográfica em diferentes vazões para todas as colunas. Considerando a eficiência, impedância, resolução, capacidade de pico, fator de retenção e hidrofobicidade, as colunas Cortecs 1,6 µm e Acquity 1,7 µm apresentaram melhor desempenho durante a análise dos fármacos em amostra de plasma. O capítulo III descreve o desenvolvimento e validação dos métodos SPME-UHPLC-MS/MS e Bio-SPME-Nano-ESI-MS/MS para a determinação dos endocanabinóides (AEA e 2-AG) em amostras biológicas. Para a otimização do processo SPME foram avaliadas as fases SPME (C18, C30 e HLB) e os solventes para dessorção (metanol, acetonitrila e isopropanol). Os aditivos modificadores de matriz, como cloridrato de guanidina, ácido trifluoroacético e acetonitrila foram avaliados por planejamento experimental. Os métodos SPME-UHPLC-MS/MS e Bio-SPME-Nano-ESI-MS/MS, com a fase HLB biocompatível, apresentaram para ambos endocanabinóides valores de LOQs de 1 ng mL-1 e 50 ng mL-1, respectivamente. O método Bio-SPME-Nano-ESI-MS/MS permitiu o direto acoplamento da fibra SPME ao espectrômetro de massas via dessorção/ionização nanoeletrospray que resultou em rápida determinação quantitativa dos endocanabinóides em amostras biológicas. / This thesis is divided into three chapters. Chapter I describes the development of a column switching UHPLCMS/MS method to determine psychotropic drugs in schizophrenic patients plasma samples simultaneously. Polytherapy is a common practice in schizophrenia treatment. Therefore, therapeutic drug monitoring has been applied to adjust doses and to customize pharmacological therapy. The column switching UHPLCMS/MS method developed here is linear at concentrations ranging from 0.025 to 1.25 ng mL-1 with R2 above 0.9950 and presents lack of fit test (p > 0.05), precision with coefficients of variation lower than 12%, and accuracy with relative standard error lower than 14%. This method was successfully applied to determine drugs in schizophrenic patients plasma samples for therapeutic drug monitoring. In chapter II, the chromatographic performance of C18 superficially porous columns and of C18 fully porous columns with different particle sizes were evaluated for analysis of psychotropic drugs by LC-MS/MS and LC-DAD. Within the LC-MS/MS system, the following chromatographic parameters were assessed: reduced plate height vs reduced linear velocity, impedance vs reduced linear velocity, chromatographic run time vs flow rate, backpressure vs flow rate, resolution, peak capacity, asymmetry, and retention factor. Within the LC-DAD system, hydrophobicity, silanol activity, and metal impurities were also examined. Columns with charged surface displayed improved chromatographic efficiency for drugs in the ionized form. Columns with particles smaller than 2 µm (Cortecs 1.6 µm, Acquity 1.7 µm, and Kinetex 1.7 µm) presented higher chromatographic efficiency for the drugs, which were in their partially ionized form. The generated mathematical models were able to predict the backpressure and the chromatographic run time at different flow rates for all the columns. Considering efficiency, impedance, resolution, peak capacity, retention factor, and hydrophobicity, columns Cortecs 1.6 µm and Acquity 1.7 µm provided the best performance during analysis of drugs in plasma samples. Chapter III describes the development and validation of the SPME-UHPLC-MS/MS and the Bio-SPME-Nano-ESI-MS/MS methods for determination of endocannabinoids (AEA and 2-AG) in biological samples. To optimize the SPME process, SPME coatings (C18, C30, and HLB) and solvents for desorption (methanol, acetonitrile, and isopropanol) were evaluated. Matrix modifier additives, such as guanidine hydrochloride, trifluoroacetic acid, and acetonitrile, were assessed by experimental design. The SPME-UHPC-MS/MS and the Bio-SPME-Nano-ESI-MS/MS methods with HLB biocompatible coating provided LOQ values of 1 ng mL-1 and 50 ng mL-1, respectively, for both endocannabinoids. The Bio-SPME-Nano-ESI-MS/MS method allowed direct coupling of SPME fibers to the mass spectrometer by desorption/ionization nanoelectrospray, which resulted in rapid quantitative determinations of endocannabinoids in biological samples.

Page generated in 0.0481 seconds