• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 253
  • 10
  • 9
  • 9
  • 8
  • 5
  • 4
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 265
  • 115
  • 80
  • 52
  • 48
  • 47
  • 39
  • 31
  • 29
  • 29
  • 23
  • 23
  • 22
  • 22
  • 20
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Desempenho de estações de tratamento de águas cinzas e negras para residências rurais, envolvendo filtros orgânicos e reatores solares / Performance overview of grey and black water treatment plants for rural residences, involving organic filters and solar reactors

Rocha, André Luiz Marques 04 February 2013 (has links)
Submitted by Reginaldo Soares de Freitas (reginaldo.freitas@ufv.br) on 2017-05-31T12:27:30Z No. of bitstreams: 1 texto completo.pdf: 2353197 bytes, checksum: c7857ff947a3da3dfb17abdaa73dd50c (MD5) / Made available in DSpace on 2017-05-31T12:27:30Z (GMT). No. of bitstreams: 1 texto completo.pdf: 2353197 bytes, checksum: c7857ff947a3da3dfb17abdaa73dd50c (MD5) Previous issue date: 2013-02-04 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / A água de reuso é uma opção promissora do ponto de vista ambiental, já que contribui para diminuição da captação e consequentemente redução nas vazões de lançamento de efluentes. O lançamento de águas cinzas e águas negras sem tratamento no ambiente deprecia a qualidade de vida das populações em função do surgimento de várias doenças. O presente trabalho objetivou monitorar e avaliar a eficiência de uma estação de tratamento de águas cinzas (ETAC) e de uma estação de tratamento de águas negras (ETAN), visando o reaproveitamento não-potável das águas cinzas e das águas negras em comunidades rurais de baixa renda. A ETAC foi montada na comunidade rural Macena, no município de Viçosa-MG. Tal sistema era constituído de biofiltro, reatores solares e sumidouro, o qual foi monitorado no período de 23 de julho de 2009 a 01 de outubro de 2009. As análises físico-químicas e microbiológicas dos efluentes foram realizadas em distintos pontos do sistema para avaliação do desempenho. A ETAC foi montada no Delineamento Inteiramente Casualizado com três tratamentos (pontos de amostragem) e cinco repetições no tempo. De acordo com os resultados obtidos durante a avaliação da estação de tratamento de águas cinzas (ETAC), conclui-se que a (ETAC) proporcionou eficiências médias de remoções de 28%, 56%, 71,3%, 76,5%, 52,5%, 71%, 61%, 4,6% e 87% nas concentrações de Condutividade Elétrica (CE), Turbidez (TB), Demanda Química de Oxigênio (DQO), Demanda Bioquímica de Oxigênio (DBO), Sólidos Totais (ST), Sólidos Suspensos Totais (SST), Fósforo Total (P total ), Nitrogênio Total (N total ) e Óleos e Graxas (OG), respectivamente. Com relação às características microbiológicas, a ETAC obteve uma eficiência de remoção média de E. coli de 3 unidades logarítmicas. A ETAN foi montada na comunidade rural de Água Limpa do município de Cajuri-MG. Tal sistema foi constituído de caixa de gordura, tanque séptico, biofiltro, reatores solares e sumidouro, o qual foi monitorado no período de 7 de maio de 2009 a 25 de junho de 2009. As análises físico-químicas e microbiológicas dos efluentes foram realizadas em distintos pontos do sistema para avaliação do desempenho. O experimento para tratamento de águas negras foi montado no Delineamento Inteiramente Casualizado com quatro tratamentos (pontos de amostragem) e seis repetições no tempo. De acordo com os resultados obtidos durante a avaliação da estação de tratamento de águas negras (ETAN), conclui-se que a (ETAN) proporcionou eficiências médias de remoções de 46%, 88%, 78,2%, 85,8%, 61,5%, 91%, 75%, 14,4% e 67,8% nas concentrações de Condutividade Elétrica (CE), Turbidez (TB), Demanda Química de Oxigênio (DQO), Demanda Bioquímica de Oxigênio (DBO), Sólidos Totais (ST), Sólidos Suspensos Totais (SST), Fósforo Total (P total ), Nitrogênio Total (N total ) e Óleos e Graxas (OG), respectivamente. Com relação às características microbiológicas, a ETAN proporcionou uma eficiência de remoção média de E. coli de 2 unidades logarítmicas. / The water reuse is a promising alternative for the viewpoint of the environment, contributing to reduced absorption and reduces the flow of effluent discharge. The release of greywater and untreated sewage depreciates environmental quality of life of populations due to the onset of various diseases. This study aimed to monitor and evaluate the capacity of a treatment plant for greywater and a treatment of sewage, for non-potable reuse of greywater and blackwater in communities low-income rural. The treatment plant grey water was set up in the rural community Macena in Viçosa-MG. This system consists of biofilters, solar reactors and sinkhole, which was controlled in the period from July 23, 2009 to October 1, 2009. The physico-chemical and microbiological characteristics of the effluents were realized in different parts of the performance evaluation system. The treatment plant greywater was mounted in a completely randomized design with three treatments (sampling points) and five replications in time. According to the results obtained during the evaluation of the water treatment station ash, it is concluded that this treatment stationgave mean elimination efficiency of 28%, 56%, 71.3%, 76.5 %, 52.5%, 71%, 61%, 4.6% and 87% concentrations of electrical conductivity, turbidity, chemical oxygen demand, biochemical oxygen demand, total solids, total suspended solids, total phosphorus, total oil and grease, nitrogen, respectively. Regarding the microbiological characteristics, the treatment plant greywater obtained an average efficiency of removal of E. coli three logarithmic units.The station blackwater treatment was mounted in the rural community of Água Limpa, in Cajuri-MG.This system consisted of the grease trap, septic tank, biological filter, solar reactors and the sinkhole, which is monitored in the period from May 7, 2009 to June 25, 2009. The physico-chemical and microbiological characteristics of the effluents were carried out in different parts of the performance evaluation system. Experience in wastewater treatment was mounted in a completely randomized design with four treatments (sampling points) and six replications in time. According to the results obtained during the evaluation of treatment plant sludge, is follows that a gave mean elimination efficiency of 46%, 88%, 78.2%, 85.8%, 61.5%, 91%, 75%, 14.4% and 67.8% to levels of electrical conductivity, turbidity, chemical oxygen demand, biochemical oxygen demand, total solids, total suspended solids, total phosphorus, nitrogen total, oil and grease, respectively. Regarding the microbiological characteristics, the station blackwater treatment obtained an average efficiency of removal of E. coli two logarithmic units.
42

Redes neurais aplicadas à inferência dos sinais de controle de dosagem de coagulantes em uma estação de tratamento de água por filtração rápida / Artificial neural networks applied to the inference of dosage control signals of coagulants in a water treatment plant by direct filtration

Gomes, Leonaldo da Silva 03 1900 (has links)
GOMES, L. da S. Redes neurais aplicadas à inferência dos sinais de controle de dosagem de coagulantes em uma estação de tratamento de água por filtração rápida. 2012. 98 f. Dissertação (Mestrado em Engenharia Elétrica) - Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2012. / Submitted by Marlene Sousa (mmarlene@ufc.br) on 2012-09-13T18:15:13Z No. of bitstreams: 1 2012_dis_lsgomes.pdf: 7198003 bytes, checksum: 6a4247c4aa5d59a00fb9744fef097ea9 (MD5) / Approved for entry into archive by Marlene Sousa(mmarlene@ufc.br) on 2012-09-25T14:35:04Z (GMT) No. of bitstreams: 1 2012_dis_lsgomes.pdf: 7198003 bytes, checksum: 6a4247c4aa5d59a00fb9744fef097ea9 (MD5) / Made available in DSpace on 2012-09-25T14:35:04Z (GMT). No. of bitstreams: 1 2012_dis_lsgomes.pdf: 7198003 bytes, checksum: 6a4247c4aa5d59a00fb9744fef097ea9 (MD5) Previous issue date: 2012-03 / Considering the importance of the chemical coagulation control for the water treatment by direct filtration, this work proposes the application of artificial neural networks for inference of dosage control signals of principal and auxiliary coagulant, in the chemical coagulation process in a water treatment plant by direct filtration. To that end, was made a comparative analysis of the application of models based on neural networks, such as: Focused Time Lagged Feedforward Network (FTLFN); Distributed Time Lagged Feedforward Network (DTLFN); Elman Recurrent Network (ERN) and Non-linear Autoregressive with exogenous inputs (NARX). From the comparative analysis, the model based on NARX networks showed better results, demonstrating the potential of the model for use in real cases, which will contribute to the viability of projects of this nature in small size water treatment plants. / Considerando a importância do controle da coagulação química para o processo de tratamento de água por filtração rápida, esta dissertação propõe a aplicação de redes neurais artificiais para inferência dos sinais de controle de dosagem de coagulantes principal e auxiliar, no processo de coagulação química em uma estação de tratamento de água por filtração rápida. Para tanto, foi feito uma análise comparativa da aplicação de modelos baseados em redes neurais do tipo: alimentada adiante focada atrasada no tempo (FTLFN); alimentada adiante atrasada no tempo distribuída (DTLFN); recorrente de Elman (ERN) e auto-regressiva não-linear com entradas exógenas (NARX). Da análise comparativa, o modelo baseado em redes NARX apresentou melhores resultados, evidenciando o potencial do modelo para uso em casos reais, o que contribuirá para a viabilização de projetos desta natureza em estações de tratamento de água de pequeno porte.
43

Genocidio velado : trajetória da EFNOB e perspectivas para o patrimônio industrial ferroviário /

Fonseca-Castro, Ellen Beatriz Santos. January 2016 (has links)
Orientador: Rosío Fernández Baca Salcedo / Banca: Rosio Fernandez Baca Salcedo / Banca: Nilson Ghiraldello / Banca: Marcelo Zarate / Resumo: Os trens são reconhecidos como patrimônio cultural pela população bauruense, e o pátio ferroviário da cidade, tombado pelo CODEPAC e em Estudo de Tombamento pelo CONDEPHAAT (Conselhos municipal e estadual, respectivamente), está sem previsão de políticas, programas ou projetos públicos de salvaguarda de seu patrimônio, com suas edificações degradadas e abandonadas. Apesar dessa situação de descaso, o complexo da Companhia Estrada de Ferro Noroeste do Brasil - CEFNOB (nosso estudo de caso) continua sendo considerado um dos melhores e mais completo exemplar de pátio ferroviário da América Latina. Muitas pesquisas na temática da ferrovia, e da Noroeste em particular, já foram desenvolvidas, entretanto, as diversas informações e resultados produzidos ainda não foram sistematizados, analisados e interpretados conjuntamente. No intuito de começar a se pensar em uma maneira de reintegrar o complexo ferroviário ao cenário urbano, esta pesquisa tem por objetivo testar se o reconhecimento do código genético do patrimônio, a partir de suas articulações socioeconômicas, simbólicas, de identidade e memória, é necessário para intervenção no complexo ferroviário da Estrada de Ferro Noroeste do Brasil (EFNOB); e, propor diretrizes urbanas sustentáveis para sua reintegração ao cenário urbano. A metodologia compreende seis etapas, sendo a primeira uma abordagem teórica sobre o patrimônio industrial ferroviário; sobre lugar, cultura e memória; métodos de intervenção; e, urbanismo ambiental. A s... (Resumo completo, clicar acesso eletrônico abaixo) / Mestre
44

Monitoramento e controle do balanceamento de unidade de bombeio mecânico usando inversor de frequência e fator de carga cíclica

Paula, Cícero Alexandre Brandão 16 March 2012 (has links)
Submitted by LIVIA FREITAS (livia.freitas@ufba.br) on 2016-02-15T19:40:33Z No. of bitstreams: 1 Dissertação_Cicero_Brandão_Final.pdf: 2013213 bytes, checksum: d134e81af3b53e4027c70fb34e1eb13f (MD5) / Approved for entry into archive by LIVIA FREITAS (livia.freitas@ufba.br) on 2016-03-17T17:17:45Z (GMT) No. of bitstreams: 1 Dissertação_Cicero_Brandão_Final.pdf: 2013213 bytes, checksum: d134e81af3b53e4027c70fb34e1eb13f (MD5) / Made available in DSpace on 2016-03-17T17:17:45Z (GMT). No. of bitstreams: 1 Dissertação_Cicero_Brandão_Final.pdf: 2013213 bytes, checksum: d134e81af3b53e4027c70fb34e1eb13f (MD5) / O desbalanceamento é inerente ao funcionamento de uma unidade de bombeio (UB). Para reduzir seus efeitos, o contrabalanceio é uma das ações que precisa ser adotada. Para atingir o balanceamento ideal é preciso buscar o equilíbrio entre os torques requerido pela haste polida e o torque fornecido pelo redutor durante o ciclo de bombeio. O objetivo principal deste trabalho é utilizar informações extraídas de medições realizadas da tensão no barramento DC de inversores de frequência, visando, promover o balanceamento das forças que atuam nesse equipamento. O balanceamento ótimo de uma unidade de bombeio mecânico foi alcançado, medindo esta variável, determinando o fator de carga cíclica (CLF), promovendo o ajuste na posição dos contrapesos e manipulando a velocidade de bombeamento. Para isto, faz-se necessário conhecer os principais métodos utilizados para contrabalancear a UB. Também foi preciso determinar o CLF por meio da tensão do barramento DC. Além disso, um controlador de tensão elétrica foi projetado e implantado em um controlador (CLP), sendo seu propósito reduzir a variabilidade da tensão no barramento do inversor. Como resultados, se tem uma redução significativa na potência consumida, em função do rendimento energético do motor que foi elevado. A variação do torque foi reduzida drasticamente, contribuindo pra uma operação mais suave do sistema, o que certamente irá elevar o tempo médio entre falhas (MTBF). Estes resultados levaram a melhoria do rendimento energético e da confiabilidade do sistema.
45

Remoção do herbicida 2,4-D por meio do tratamento convencional da água e adsorção em carvão ativado granular em instalação piloto

Brega, Renata Santos 01 July 2014 (has links)
Submitted by Maykon Nascimento (maykon.albani@hotmail.com) on 2014-10-20T19:42:42Z No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertacao.texto completo.Renata.pdf: 2944882 bytes, checksum: a014f9f63e76c5f39ddf6fda8ee9a824 (MD5) / Approved for entry into archive by Elizabete Silva (elizabete.silva@ufes.br) on 2014-11-25T20:31:01Z (GMT) No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertacao.texto completo.Renata.pdf: 2944882 bytes, checksum: a014f9f63e76c5f39ddf6fda8ee9a824 (MD5) / Made available in DSpace on 2014-11-25T20:31:02Z (GMT). No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertacao.texto completo.Renata.pdf: 2944882 bytes, checksum: a014f9f63e76c5f39ddf6fda8ee9a824 (MD5) Previous issue date: 2014 / O crescimento populacional empurra a produção agrícola em direção ao uso intensivo dos agrotóxicos que aumentam a produtividade. Porém, seu uso incorreto pode resultar em grave problema para as estações de tratamento da água e impactar negativamente na saúde pública. Segundo estudos em escala laboratorial, o tratamento convencional, um dos mais utilizados no Brasil, apresenta remoção insignificante do 2,4-D. A adsorção em carvão ativado tem se demonstrado como tecnologia eficiente na remoção de diversos contaminantes, dentre eles os agrotóxicos. Assim, foi avaliada a remoção dos herbicidas 2,4-D e 2,4,5-T e metabólito 2,4-DCP, utilizando o tratamento convencional e a adsorção em coluna de carvão ativado granular em instalação piloto. O carvão ativado granular empregado foi o derivado da casca de coco. A concentração dos herbicidas foi analisada por cromatografia líquida de alta eficiência com detector por arranjo de diodos e extração em fase sólida. A associação do tratamento convencional com a adsorção em carvão ativado granular apresentou elevada remoção do 2,4-D (99%) atingindo concentrações finais abaixo do limite da Portaria MS n° 2914/2011. O tratamento convencional, no entanto, também apresentou remoção do 2,4-D (35 a 59%), sendo o maior percentual obtido na decantação (30 a 52%), indicando que houve interação entre a matéria orgânica natural e o 2,4-D, contribuindo para sua remoção nessa etapa. O 2,4-DCP e 2,4,5-T apresentaram concentrações abaixo do limite de detecção. / The population growth pushes agricultural production towards intensive use of pesticides that increase productivity. However, incorrect use can result in serious problem at water treatment plants and negatively impact in public health. According to laboratory-scale studies, conventional treatment, one of the most used in Brazil, presents negligible removal of 2,4-D. The activated carbon adsorption have been documented to be effective for the removal of various contaminants, including pesticides. Thus, it was evaluated the removal of the herbicides 2,4-D and 2,4,5 -T and metabolite 2,4- DCP using the conventional treatment and granular activated carbon adsorption, in a pilot-plant. The granular activated carbon used was manufactured from coconut shell. The herbicides concentration was analyzed by High Performance Liquid Chromatography with diode array detection and solid phase extraction. The combination of conventional treatment and granular activated carbon adsorption showed high removal of 2,4-D (99%) reaching final concentrations below the limit of Portaria MS n° 2914/2011. Conventional treatment, however, also showed considerable removal of 2,4- D (35-59%), with a high percentage removal obtained in sedimentation (30-52%), suggesting that there were interaction between natural organic matter and 2,4-D, increasing the removal in this step. 2,4-DCP and 2,4,5-T showed concentrations below the detection limit.
46

O uso da arquitetura da paisagem no tratamento final dos efluentes de estações de tratamento de esgotos em São José/SC

D'Acampora, Bárbara Heliodora Alves January 2013 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências Tecnológicas, Programa de Pós-Graduação em Arquitetura e Urbanismo, Florianópolis, 2013. / Made available in DSpace on 2013-12-05T23:12:46Z (GMT). No. of bitstreams: 1 321674.pdf: 8657291 bytes, checksum: bd14220d5ac3edf08fcd3baee39d2f58 (MD5) Previous issue date: 2013 / O crescimento populacional e a falta de planejamento são graves problemas no desenvolvimento das cidades brasileiras, que geram a deficiência de coleta e de tratamento de esgotos urbanos, causando problema de saúde pública. Por sua vez, ocasionam também a carência de espaços verdes, que apesar de possuírem áreas de vegetação, a sua qualidade não está ligada às necessidades da população, atingindo a qualidade de vida. Dentro desse enfoque, o Município de São José/SC possui uma deficiência de vegetação urbana e um único sistema de tratamento que cobre uma parte ínfima da área urbana. Portanto, esta pesquisa tem por objetivo articular as possíveis conexões entre a arquitetura da paisagem e o tratamento final de efluentes das ETEs no Município de São José/SC. O estudo possui análise espacial de campo e solução de problemas específicos para sociedade, através do tratamento de dados quali-quantitativos, revisão de material bibliográfico e documental sobre os tratamentos de esgotos urbanos, que unem-se aos espaços verdes em São José. O tratamento de esgoto com Jardins Filtrantes, utilizado como espaço verde é uma alternativa viável como solução ao complemento de tratamento de esgotos urbanos convencionais, criando uma paisagem concebida como um jardim ou parque público. Constata-se, portanto, os efeitos positivos dessa integração sobre o ambiente, a população e a economia urbana josefense, através de uma solução integrada à natureza.<br> / Abstract : Population growth and lack of planning are serious problems in the Brazilian cities' development, which generates the deficiency on collection and on treatment of urban sewage, causing public health problem. By other hand, leads also to the lack green spaces, which despite having areas of vegetation, its quality is not linked to the needs of the population, affecting the quality of life. Under this approach, the City of São José/SC has a deficiency of urban greenery and a single treatment system that covers a tiny part of the urban area. Therefore, this research aims to articulate the possible connections between landscape architecture and final treatment of effluent from the STPs in São José/SC. The study has a field's spatial analysis on troubleshooting specific for society, data processing qualitative and quantitative data, bibliography and documentary about the treatment of urban sewage, uniting the green spaces of São José. The sewage treatment by filtering gardens, used as green space is a viable alternative solution to complement conventional urban sewage treatment, creating a landscape conceived as a garden or public park. Noticing, therefore, the positive effects of such integration on the environment, population and urban economy of São José through an integrated solution to nature.
47

Caracterização e clarificação por sedimentação da água de lavagem de filtro rápido de uma estação de água

Olinger, Cristiano January 2002 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Ambiental. / Made available in DSpace on 2012-10-20T03:42:01Z (GMT). No. of bitstreams: 0Bitstream added on 2014-09-26T01:09:09Z : No. of bitstreams: 1 193973.pdf: 14011055 bytes, checksum: 494fe92048f0a8b85d532725557a7056 (MD5) / Atualmente, as estações de tratamento de água, tem utilizado em sua maioria, os corpos receptores mais próximos ou a rede de águas pluviais como destino final para os resíduos formados durante o processo de tratamento A maior parcela destes resíduos é formada pela água proveniente da lavagem dos filtros e pode chegar, dependendo da ETA, de 1 a 5 % do volume total de água tratada. A diminuição destes resíduos formados e disposição final adequada deve ser estudada para que se possibilite a adoção destes métodos por todas as ETAs. O reaproveitamento da água de lavagem dos filtros, após sua clarificação, é importante pois contribui para o atendimento da crescente demanda de água e a diminuição do despejo, que será tratado e/ou enviado para a disposição final. Neste trabalho foi estudada a caracterização da água de lavagem dos filtros de uma ETA que utiliza sulfato de alumínio como coagulante primário. Através desses ensaios verficam-se a possibilidade de reaproveitamento da água de lavagem dos filtros, mediante a recirculação de parte desta água que possui após algum tempo qualidade superior a água aduzida a ETA e também a viabilidade de clarificação por sedimentação da água de lavagem.
48

A importância da água para a percepção turística na bacia do rio formoso em Bonito-MS

Silva, Priscila Varges da [UNESP] 27 July 2015 (has links) (PDF)
Made available in DSpace on 2016-03-07T19:21:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-07-27. Added 1 bitstream(s) on 2016-03-07T19:24:58Z : No. of bitstreams: 1 000857480.pdf: 7844600 bytes, checksum: 7ca3607be9949ced940828a854b51c06 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Em diversos destinos turísticos os recursos hídricos são os principais elementos de potencialidade e atração turística. A prática do turismo utilizando a água como atrativo, atribui valor à qualidade da água, já que para que o turismo aconteça, esta deve apresentar características que exerçam o poder de atração e de satisfação do turista. Além disso, as águas devem ter características físico-químicas compatíveis às normas estabelecidas ao uso turístico. A bacia do rio Formoso é a principal bacia hidrográfica do município de Bonito-MS e grande parte dos atrativos turísticos do município estão relacionados à água e nela inseridos. A presente tese buscou analisar as características fisiografias da bacia, avaliar a qualidade da água nos atrativos turísticos e a percepção dos turistas após o contato com a mesma, visando compreender a importância da água para a atividade turística a partir da visão dos turistas, e quais os fatores que influenciam na qualidade e balneabilidade da água para esta atividade ocorra na bacia do rio Formoso. A pesquisa foi desenvolvida a partir da revisão bibliográfica, da elaboração e análise de mapas, da análise da água nos 15 atrativos turísticos pesquisados (tarefa realizada em 2 campanhas), e da elaboração, aplicação e análise de entrevistas com os turistas... / Water resources are considered the most relevant and potential elements, as well as a tourist attraction factor in many touristic destinations. Tourism practice using water as an attraction gives value to water quality. Into this context, it may be considered that to have the tourism activity, the water must have all the characteristis able to generate the feeling of attraction and satisfaction to tourists. Beyond that, water must have compatible physio-chemical characteristics to the stabilished rules regarded to tourism use. Rio Formoso basin is the most imnportant water basin of Bonito-MS in which part of the tourist attracation related to the water are located in it. This present thesis tried to analyse the basin physiographic characteristics, evaluate the water quality of the touristic attractions as well as the perception of the tourists after their contact with it, in an attempt of understanding the water importance on tourism activity from the tourists point of view. It was also a goal of the present research, the evaluation of all the factors that did influence the water quality allowing the bathing and tourism practice into Formoso basin. The study was developed throughout a bibliographic revision, maps's elaboration and analysis, water analysis of 15 studied attractions (duty developed in two differente stages) as well as elaboration, application of interview to tourists... / CAPES: Projeto 153/12
49

Fauna de Ichneumonidae (Hymenoptera: Ichneumonoidea) em um agroecossistema cafeeiro no Estado de São Paulo

Fernandes, Daniell Rodrigo Rodrigues [UNESP] 17 December 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:46Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-12-17Bitstream added on 2014-06-13T19:21:15Z : No. of bitstreams: 1 fernandes_drr_dr_jabo.pdf: 1092108 bytes, checksum: 64d1e66eebe2f7b467eec94db5f808ee (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste trabalho foi estudar a fauna de Ichneumonidae (Hymenoptera: Ichneumonoidea) em um agroecossistema cafeeiro localizado em Cravinhos, SP, Brasil, identificar as espécies encontradas, analisar a diversidade, sazonalidade e os métodos de amostragem. A amostragem foi realizada semanalmente entre maio de 2005 e abril de 2007 com armadilhas de Moericke e luminosa modelo Jermy. As armadilhas de Moericke foram fixadas em estacas de madeira próximas aos terços inferior e médio da planta e permaneceram ativas por 48 horas/semana; foram estabelecidos 20 pontos de amostragem em um ha e, em cada ponto, instalados três conjuntos de armadilhas, distantes entre si por um metro. As armadilhas luminosas foram fixadas de forma que sua cobertura ficasse na altura do dossel das plantas; foram instaladas duas armadilhas em um talhão de um ha, ativas por dois períodos de 12 horas/semana. Foram obtidos 1803 exemplares de Ichneumonidae, de 62 gêneros e 109 espécies, dentre as quais 37 nominais e 72 morfoespécies, distribuídas em 16 subfamílias. As espécies mais abundantes foram Lissonota sp. (Banchinae), Ophion flavidus Brullé, 1846 (Ophioninae), Mesostenus alvarengae Porter, 1973 (Cryptinae), Thymebatis sp. 1 (Ichneumoninae), Netelia sp. (Tryphoninae), Pimpla sp. (Pimplinae), Eiphosoma laphygmae Costa Lima, 1953 (Cremastinae) e Syzeuctus sp. (Banchinae), com 578, 318, 102, 97, 87, 66, 52 e 49 exemplares capturados, respectivamente. O índice de diversidade de Margalef foi de 14,41, o de Shannon de 2,81 e o de Pielou 0,60. Foram coletados 1243 (68,9% do total) exemplares com armadilhas Moericke e 560 (31,1%) com armadilha luminosa. A diversidade de espécies de Ichneumonidae encontrada foi maior na armadilha Moericke em relação à luminosa; para grupos de hábito norturno... / The aim of this work was to study the fauna of Ichneumonidae (Hymenoptera: Ichneumonoidea) in a coffee agroecosystem located in Cravinhos, Sao Paulo, Brazil. The identification of species, the analysis of its diversity and seasonality, and the study of sampling methods were performed. Sampling was carried out weekly between May 2005 and April 2007, using Moericke and light traps (Jermy model). Moericke traps were fixed to wood stake near the lower and middle thirds of the coffee plants and kept there during 48 hours/week; twenty sample points were evaluated in one hectare, each one of them with three Moericke traps, distant one meter each other. Light traps were set at the height of the coffee plants´canopy. Two light traps were twice installed for a 12 hours/week period, in a 1-ha plot. A total of 1,803 specimens of Ichneumonidae were collected, belonging to 16 subfamilies, 62 genera and 109 species (37 nominal and 72 morphospecies). Lissonota sp. (Banchinae), Ophion flavidus Brullé, 1846 (Ophioninae), Mesostenus alvarengae Porter, 1973 (Cryptinae), Thymebatis sp. 1 (Ichneumoninae), Netelia sp. (Tryphoninae), Pimpla sp. (Pimplinae), Eiphosoma laphygmae Costa Lima, 1953 (Cremastinae) and Syzeuctus sp. (Banchinae) were the most abundant, totaling 578, 318, 102, 97, 87, 66, 52 and 49 specimens collected, respectively. The Margalef and Shannon diversity indexes were, respectively, 14.41 and 2.81; and Pielou's evenness index was 0.60. A total of 1,243 (68.9% of total) ichneumonids were collected with Moericke traps and 560 (31.1%) with light traps. The diversity of ichneumonid species was higher in Moericke traps than in light traps. However, for groups with nocturnal habits, opposite results were observed. Moericke traps installed in the lower and middle third of the plants did not differ to ichneumonids... (Complete abstract click electronic access below)
50

Aplicação de inversor de freqüência para economia de energia elétrica, em sistema de irrigação por aspersão

Araújo, João Alberto Borges de [UNESP] 12 1900 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:44Z (GMT). No. of bitstreams: 0 Previous issue date: 2003-12Bitstream added on 2014-06-13T19:22:15Z : No. of bitstreams: 1 araujo_jab_dr_botfca.pdf: 1306145 bytes, checksum: 073270ab02463cb248ef1038fe9a2769 (MD5) / A crise energética ocorrida durante o ano de 2001 alertou todos os setores produtivos, em especial o setor rural, onde o consumo de energia elétrica aumentou acentuadamente na irrigação nos últimos anos. A maior parte da energia consumida está no acionamento de conjuntos motobomba para irrigação. Inúmeras pesquisas realizadas relatam que a maioria dos desperdícios está no superdimensionamento dos sistemas moto-bombas e nos controles de vazão e pressão necessários ao manejo da irrigação. Tais manobras introduzem perdas de carga no sistema promovendo desperdícios de energia elétrica e consequentemente aumentando os custos de produção. Com base neste contexto, esta pesquisa teve por objetivo avaliar o comportamento elétrico e hidráulico de um conjunto motobomba em um sistema de irrigação por aspersão em condições de acionamento convencional com rotação constante e variável através do uso de um inversor de freqüência. Para a realização do experimento em uma primeira fase, instalou-se um sistema de bombeamento convencional por aspersão operando com rotação constante. Em uma segunda fase instalou-se um sistema de acionamento com rotação variável, composto de um transdutor de pressão e um inversor de freqüência o qual atuou adequando a pressão préestabelecida em relação a variação de vazão. O confronto técnico entre os dois sistemas, demostrou a viabilidade econômica da instalação de inversores de freqüência no acionamento de motores elétricos trifásicos nos sistemas de irrigação por aspersão. Com a implantação do sistema em campo, pode-se avaliar e quantificar a economia de energia elétrica, entre os dois sistemas avaliados, demonstrando a viabilidade técnica e econômica, do inversor de freqüência em função do números de horas anuais de funcionamento. O sistema operando com inversor de freqüência manteve a pressão de... .

Page generated in 0.0742 seconds