• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 340
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 349
  • 349
  • 218
  • 216
  • 46
  • 35
  • 34
  • 29
  • 26
  • 26
  • 25
  • 24
  • 23
  • 23
  • 22
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
171

Comparação entre o pericárdio bovino decelularizado e o pericárdio bovino convencional utilizado na confecção de biopróteses valvares cardíacas / Comparison between the decellularized bovine pericardium and the conventional bovine pericardium used in the manufacturing of cardiac bioprosthesis

Jean Newton Lima Costa 15 February 2005 (has links)
O pericárdio bovino tratado com glutaraldeído (GTA) e armazenado em formaldeído tem sido utilizado para confecção de biopróteses cardíacas ao longo das últimas décadas, já se tendo acumulado grande experiência com seu manuseio. Sabemos, no entanto, que o uso do GTA associadamente à presença de restos celulares existentes em meio às fibras de colágeno e elastina do pericárdio, são fatores indutores de resposta inflamatória e de enucleação de cristais de cálcio, o que compromete a durabilidade da bioprótese in vivo a longo prazo. No presente trabalho, tivemos como objetivo comparar a resistência mecânica do pericárdio decelularizado com o pericárdio convencional, assim como avaliar sua capacidade de induzir resposta inflamatória em modelo experimental com ratos. Para estudar as duas técnicas, dividimos os pericárdios em dois grupos: Grupo I - pericárdio submetido a tratamento convencional com GTA e Grupo II - pericárdio submetido a tratamento de decelularização previamente ao tratamento convencional com GTA. Após o processamento químico dos pericárdios, as amostras do Grupo II foram histologicamente avaliadas para confirmar a eficácia da decelularização. A seguir, analisamos a resistência mecânica nos dois grupos de pericárdio através dos testes de tração e de desnaturação térmica. Em nossa casuística, os dois grupos tiveram desempenho semelhante. A capacidade de induzir resposta inflamatória foi avaliada em estudo experimental em 50 ratos Wistar, machos, com 3 meses de idade, os quais foram submetidos a implante subcutâneo no abdome de fragmentos de pericárdio dos dois grupos. Igualmente, não evidenciamos diferença significativa. Nossa terceira etapa de avaliação consistiu em confeccionar 3 biopróteses (mitral n. 29) com o pericárdio decelularizado e que foram submetidas a avaliação hidrodinâmica juntamente com uma bioprótese convencional de teste. As biopróteses decelularizadas mostraram ter desempenho hidrodinâmico semelhante à prótese de teste e ao padrão de avaliação de próteses já conhecido da Braile Biomédica (S.J.Rio Preto-SP), todas atingindo a marca de 150 milhões de ciclos. A avaliação histológica do pericárdio das próteses ao fim da ciclagem mostrou padrão microscópico habitual, não tendo havido ruptura ou fragmentação anormal induzida por estresse mecânico. Temos como conclusão que a técnica de decelularização mantém a resistência física do pericárdio em comparação àquele convencionalmente preparado, não levando à fragmentação da matriz de colágeno e elastina e nem à perda de sua resistência mecânica tanto estática quanto dinâmica, além de não ter induzido resposta inflamatória diferente daquela habitualmente encontrada no pericárdio convencional / The bovine pericardium treated with glutaraldehyde (GTA) and stored in formaldehyde has been used in the manufacturing of cardiac bioprosthesis through the past decades, and a great knowledge has been acquired in this field. We know however that the use of the GTA and the presence of cell debris among the collagen and elastin fibers are triggers to induce inflammatory response and calcium deposition in the tissue, what compromises the long term durability of bioprosthesis in vivo. In this paper, our objective was to compare the decellularized and the conventional pericardium mechanical resistance and also its capability of inducing inflammatory response in an animal experimental model. In order to study these two techniques, we divided the pericardia into two groups: Group I- pericardia conventionally treated with GTA and Group II - pericardia previously decellularized and then conventionally treated with GTA. At first, after the pericardia chemical treatment, we performed histological analysis of Group II to certify the efficacy of the decellularization process. Afterwards, we analyzed the mechanical resistance in both groups using the stretching and shrinkage tests. In our samples, both groups had the same performance. The capacity of inducing inflammatory response was evaluated in an experimental study with 50 Wistar rats, male, 3 months old, which were operated to receive the pericardia patches of both groups underneath the dermal layer in the abdomen. We also did not find any difference between the groups. The third step of evaluation was to manufacture three decellularized bioprosthesis and one no decellularized one that were submitted to hydrodynamic tests. The decellularized and the test prosthesis showed the same performance and there was also no difference when compared with the known performance of the Braile Biomédica\'s (S.J.R. Preto-SP) bioprosthesis. They all reached 150 million cicles. The histological avaluation of the bioprosthesis showed the usual microscopic pattern, and there was no abnormal rupture or fragmentation caused by mechanical stress. We have therefore reached to the conclusion that the decellularization technique keeps the physical resistance of the pericardium when compared with the conventionally prepared. It does not cause damage or fragmentation of the collagen and elastin fibers and does not lead to loss of the mechanical resistance. And also, there was no difference in both groups regarding to inflammatory response studied in the animal model
172

Uso de antipsicóticos e prevenção de re-hospitalizações em pacientes com esquizofrenia / Antipsychotics use and rehospitalization prevention in patients with schizophrenia

Ana Paula Werneck de Castro 11 September 2009 (has links)
INTRODUÇÃO: Re-hospitalização é uma medida de desfecho reconhecida e utilizada em estudos para acessar prevenção de recaída que é considerada um dos principais indicadores de efetividade de um antipsicótico. Foi testada a hipótese que a clozapina seria superior aos demais antipsicóticos na prevenção de re-hospitalizações em pacientes com esquizofrenia que receberam alta do Instituto de Psiquiatria do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo entre 1 de dezembro de 1997 e 31 de dezembro de 2004. MÉTODOS: Este foi um estudo observacional de coorte, retrospectivo, desenhado para avaliar o tempo de re-hospitalização de pacientes que receberam alta em uso de antipsicóticos convencionais ou antipsicóticos de segunda geração, exceto clozapina ou clozapina, por um período de três anos. A análise de sobrevivência foi estimada pela fórmula produtolimite de Kaplan-Meier. Foi utilizado o modelo de regressão de Cox para identificar fatores associados à re-hospitalização. RESULTADOS: Dos 464 pacientes com esquizofrenia que receberam alta no período do estudo, foram selecionados 242 pacientes. A re-hospitalização foi observada em 12 (17%) pacientes em uso de antipsicóticos convencionais, 27 (24%) pacientes em uso de antipsicóticos de segunda geração, exceto clozapina, e nove (15%) pacientes em uso de clozapina. As análises de sobrevivência demonstraram uma diferença estatisticamente significante entre os três grupos e entre os grupos de antipsicóticos de segunda geração e clozapina. As variáveis clínico-demográficas não foram associadas à re-hospitalização. CONCLUSÕES: O grupo de pacientes que recebeu clozapina apresentou menor taxa de re-hospitalização do que os demais grupos. As diferenças entre tempo de rehospitalização foram estatisticamente significantes entre os três grupos e entre os grupos de pacientes que receberam clozapina e antipsicóticos de segunda geração. Os resultados são limitados pela heterogeneidade da gravidade do transtorno entre os grupos. / INTRODUCTION: An important outcome parameter of drug effectiveness in schizophrenia is relapse prevention which can be reliably measured by time to rehospitalization. We tested the hypothesis that clozapine was superior to other antipsychotics in preventing rehospitalization in patients with schizophrenia discharged from the Institute of Psychiatry. METHODS: This is a retrospective observational cohort study designed to evaluate rehospitalization rates of patients with schizophrenia discharged from the Institute of Psychiatry of the Hospital das Clínicas of the University of Sao Paulo between Dec 1, 1997 and Dec 31, 2004 on a regimen of either conventional antipsychotics or nonclozapine second generation antipsychotics or clozapine during a three years follow-up. Risk factors associated with rehospitalization were examined by Cox regression model and survival curves were estimated by the product-limit formula (Kaplan-Meier). RESULTS: Of the 464 patients with schizophrenia discharged from hospital 242 met criteria to enter the study. They were followed at IPq outpatient clinic for three years. Of these 12 (17%) patients discharged in use of conventional antipsychotic, 27 (24%) in use of non-clozapine second generation antipsychotic, and nine (15%) in use of clozapine were rehospitalized. Survival analysis demonstrated a significant difference in timeto-rehospitalization between groups and between clozapine and second generation antipsychotics groups. CONCLUSIONS: Patients with clozapine were less rehospitalized than the others groups. The differences in time to rehospitalization were statistically significant between the three groups and between clozapine and nonclozapine second generation antipsychotics groups. Results were limited due to the heterogeneity of severity of illness between groups.
173

Efeito da reeducação postural global e do alongamento estático segmentar em portadoras de disfunção temporomandibular: um estudo comparativo / Postural global reeducation and segmental static stretch in individuals with temporomandibular disorder: a comparative study

Sâmia Amire Maluf 13 February 2007 (has links)
Pacientes com desordens temporomandibulares (DTMs) miogênicas em geral apresentam dor nos músculos elevadores da mandíbula durante a palpação e mastigação, com atividade eletromiográfica postural aumentada e limitação de movimento. Além disso, áreas vizinhas como ombros e região cervical podem apresentar tensão, encurtamentos musculares e pontos-gatilho. Os exercícios terapêuticos têm sido utilizados na reabilitação e prevenção das DTMs miogênicas, porém de forma associada a outros recursos da fisioterapia e/ou odontologia, o que impede a verificação clara de seus efeitos nas DTMs. Este estudo teve por objetivo comparar os efeitos da reeducação postural global (RPG) e do alongamento estático segmentar no tratamento de 24 mulheres portadoras de DTM miogênica, Helkimo III. Foram avaliadas a intensidade dos sintomas (por escalas visuais analógicas), a qualidade de vida (pelo questionário SF-36), a eletromiografia e dolorimetria dos músculos masseter, temporal, trapézio e esternocleidomastóideo. As 24 pacientes foram divididas randomicamente em dois grupos. O tratamento do primeiro grupo consistiu de duas posturas da RPG, uma para a cadeia anterior e outra para a cadeia posterior; o tratamento do segundo consistiu em alongamento segmentar dos músculos da mastigação, região cervical e membros superiores. Em ambos os protocolos foram acrescentadas manobras de pompage. Os dois grupos realizaram oito sessões individuais com freqüência semanal e duração de 40 minutos. Os dados foram analisados estatisticamente, com nível de significância de 5%. Os resultados sugerem que os dois tipos de alongamento tiveram igual eficácia no alívio dos sintomas (p < 0,005), melhora da qualidade de vida (p < 0,005), diminuição da atividade eletromiográfica do músculo masseter (p < 0,005) e elevação do limiar de dor (p < 0,005), tanto logo após o tratamento quanto na reavaliação realizada dois meses depois por avaliador cego. / Patients with myogenic temporomandibular disorders (TMD) usually present pain at palpation and during mastication in mandible muscles, increased postural electromyographic activity, and movement limitation. Also, nearby areas such as shoulders and cervical region may present tension, muscle shortening and trigger points. Therapeutic exercises have been used in rehabilitation and prevention of myogenic TMDs; however, these are usually associated to other physical therapy or odontology resources, which prevents a clear assessment of the impact of the exercises alone. This study aims at comparing the effects of postural global reeducation (PGR) and segmental static stretch in treating 24 women with myogenic TMD, Helkimo III. Intensity of symptoms was evaluated by means of visual analog scales, quality of life by the SF-36 inventory, and electromyography and dolorimetry were measured at masseter, temporalis, trapezius and sternocleidomastoid muscles. Patients were randomly divided into two groups; group 1 treatment consisted of two PGR postures, one for the anterior chain and the other for the posterior muscle chain; group 2 treatment consisted of segmental stretch of the masticatory muscles, cervical region and upper limbs. Pompage manoeuvres were added to both protocols. Patients of both groups had 8 individual weekly sessions lasting 40 minutes each. Data were statistically anaIysed, with significance level set at 5%. Results show that both kinds of stretching had the same effectiveness in relieving symptoms (p < 0.005), improving quality of life (p < 0.005), decreasing electromyographic activity in the masseter muscle (p < 0.005), and lifting pain threshold (p < 0.005), both immediately after treatment and in reevaluation held two months later by a blind assessor.
174

"Compensação automática do tubo "ATC(R)": uma comparação com a ventilação com pressão de suporte em simulador do sistema respiratório" / Automatic tube compensation "ATC(R)" : a comparison with pressure support ventilation in respiratory system simulator

Germano Forti Junior 22 July 2004 (has links)
INTRODUÇÃO: altos valores de pressão de suporte em pacientes obstrutivos crônicos (DPOC) podem levar a dissincronia paciente – ventilador e conseqüente aumento de trabalho e desconforto respiratório que podem ser agravados devido a tubos endotraqueais (TET) estreitos. Estudos revelam que a Compensação Automática do Tubo (ATC) pode compensar o trabalho imposto pelo tubo e melhorar o conforto respiratório, o que sugere melhora da sincronia paciente – ventilador, assunto pouco estudado na ATC principalmente em situações de obstrução ao fluxo da via aérea. OBJETIVO: comparar o desempenho entre a ATC e PSV do ventilador Evita 4. MATERIAL E MÉTODOS: um simulador de 2 compartimentos (TTL Michigan) foi conectado a um ventilador drive (Bear1000), determinando quatro situações de respiração espontânea: E1 e E2R7 (esforço normal e alto com resistência normal), E1 e E2R20 (esforço normal e alto com resistência alta). O segundo compartimento foi conectado a outro simulador (Bear Lung) simulando as pressões pleural e de via aérea, o qual foi conectado ao ventilador teste Evita 4 através de dois tubos endotraqueais (TET) 7,5 e 8,5 mm. Estudamos os efeitos de 4 valores de PS (5, 10, 15 e 20 cmH2O), ATC e ATC+PSV de 5 e 10 cmH2O. Para avaliar a compensação expiratória comparamos ATC+CPAP de 5 cmH2O com CPAP de 5 cmH2O. O grupo CONTROLE foram as 4 situações de respiração espontânea com o modelo sem o TET e sem o Evita 4. Foram analisados o trabalho inspiratório total e imposto (WOB), produto pressão-tempo inspiratório total e imposto pelo tubo (PTP), produto pressão-tempo expiratório (PTPexp), pressão proximal, e tempos de disparo (&#916;t inicial) e ciclagem (&#916;t final) do ventilador teste. RESULTADOS: a ATC e ATC+PSV geralmente determinaram valores de WOB e PTP menores ou similares que a PSV na situação de maior esforço (E2). Ao contrário, nas demais situações, o WOB e PTP foram menores na PSV do que na ATC e ATC+PSV. O &#916;t inicial foi menor que 100 milissegundos em todas as situações nos dois modos ventilatórios. O &#916;t final foi menor na ATC e ATC+PSV do que na PSV em todas as situações. Na maioria das situações, a compensação expiratória da ATC+CPAP contra CPAP, determinou uma redução do PTPexp. CONCLUSÕES: na compensação do trabalho respiratório, no maior esforço, geralmente a ATC é equivalente a PSV de 5 cmH2O. No menor esforço, ATC e ATC+PSV determinam menor alivio do trabalho respiratório do que a PSV nas comparações que realizamos. A ATC e ATC+PSV sempre determinam melhor sincronia na ciclagem do que a PSV em modelo mecânico. Em CPAP, quando a ATC está ativa determina menor resistência da válvula exalatória sem alterar o controle da PEEP traqueal. / We evaluated the performance of the automatic tube compensation (ATC) and pressure support ventilation (PSV) of Evita 4 ventilator in respiratory system simulator at 4 different situations (2 effort and 2 resistance). The PSV was compared with ATC and with ATC+PSV and the CPAP with ATC+CPAP. The ATC resulted in the same work as PSV of 5 cmH2O in only 1 out of 4 simulations, in which ATC+PSV was also superior to PSV. The delay time in cycling was lower in ATC and ATC+PSV in 4 simulations. The ATC+CPAP reduced the expiratory pressure-time product in relation to CPAP. Hence, the compensation by ATC is equivalent to the PSV of 5 cmH2O. The combination ATC+PSV is more effective. The ATC and ATC+PSV provide better synchronism than PSV. The ATC expiratory compensation results in less expiratory work.
175

Estudo comparativo entre a via de acesso minimamente invasiva posterior e a via de acesso lateral direta nas artroplastias totais do quadril não cimentadas / Prospective comparative study of the minimally invasive posterior approach and the direct lateral approach to total hip uncemented arthroplasty

José Ricardo Negreiros Vicente 21 November 2007 (has links)
Um estudo terapêutico comparativo prospectivo é realizado para avaliar o acesso posterior minimamente invasivo em artroplastia total do quadril comparado com o acesso lateral direto tradicional. O estudo inclui 76 pacientes submetidos à artroplastia total do quadril primárias não cimentadas por diagnóstico de osteoartrose primária e secundária. Não são incluídos, pacientes com qualquer tipo de coagulopatia, em uso de anticoagulantes ou antiagregante plaquetário, pacientes hipertensos sem controle medicamentoso, pacientes submetidos à qualquer cirurgia prévia do quadril, e pacientes com seqüela de displasia do desenvolvimento do quadril que tenham a cabeça femoral ectópica. O objetivo principal deste estudo é avaliar a perda volêmica que ocorre nestes pacientes. Há diferença de média de idade (p=0,017) no acesso minimamente invasivo (50,1 anos) em relação ao grupo controle (56,8 anos), porém não observamos diferenças entre os grupos quanto ao índice de massa corpórea, lado operado e diagnóstico inicial. Observa-se um sangramento menor (p<0,001) no período intra-operatório (745,6 ml contra 1282,8 ml), assim como, menor sangramento total (p<0,001) no acesso minimamente invasivo posterior (1083,5 ml contra 1682,3 ml). Relatamos diferença entre os grupos quanto à necessidade de transfusão alogênica, favorável aos pacientes do grupo minimamente invasivo (p=0,02), com 8,8% dos pacientes sendo transfundidos em relação a 28,6% dos pacientes do grupo controle. Nossa estimativa de sangramento no acesso minimamente invasivo posterior é significativamente maior que a literatura, porém a quantidade de unidades de concentrados de hemáceas transfundidas,assim como, a proporção de pacientes transfundidos são menores em relação aos outros autores. Concluímos que os pacientes submetidos ao acesso minimamente invasivo posterior apresentam menor sangramento, melhor resultado clínico precoce e posicionamento adequado dos componentes da prótese. / A therapeutic, comparative, prospective study was carried out to evaluate the minimally invasive posterior approach to total hip arthroplasty in relation to the traditional direct lateral approach. The study included 76 cases of primary total hip arthroplasty due to a diagnosis of primary or secondary osteoarthrosis. Patients were excluded from the study if they presented any type of coagulopathy and were using anticoagulants or platelet antiagregants; hypertension without medicinal control; any previous hip surgery; and sequelae of hip developmental dysplasia that might have led to an ectopic femoral head. The objective of our study was to evaluate the blood loss among patients for whom the minimally invasive posterior access is used. Regarding our patients\' ages, we observed a significant difference between the two groups: the mean age of the mini-incision group (50,1 years) was lower than the mean of the control group (56,8 years), p= 0.01. Lower total estimated bleeding was found in the mini-incision group (means of 1083,5 ml versus 1682,3 ml; p < 0.001) and lower intraoperative bleeding (means of 745,6 ml versus 1282,8 ml; p <0.001). There was difference in the need of allogenic transfusion between the two groups (8,8% versus 28,6%,p = 0.13). Our volumes of bleeding from the minimally invasive posterior approach were significantly higher than in the literature, but the mean quantity of transfused red cells and the proportion of transfused patients were both significantly lower than in the literature. Our final impression of the minimally invasive approach is positive with regard to lower blood loss, better clinical results after six months and a satisfactory alignment of the acetabular and femoral components.
176

Estudo comparativo do posicionamento acetabular e sua relação com osteoartrite primária do quadril / Comparative study of acetabular positioning and its relationship with primary osteoarthritis of the hip

Adriano Melo Correia 16 January 2008 (has links)
O presente estudo destinou-se a realizar uma análise comparativa entre a osteoartrite de quadris e o posicionamento acetabular através de exames radiográficos e de tomografia computadorizada. Foram incluídos 13 pacientes portadores e oito não-portadores de osteoartrite primária do quadril, recrutados no Ambulatório do Instituto de Ortopedia e Traumatologia do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo. Os exames foram submetidos à medição das seguintes variáveis: ângulos acetabulares, ângulo centro-borda, sinal do entrecruzamento, largura e profundidade do acetábulo no RX; anteversão e ângulos setoriais acetabulares nos tomogramas. Não se verificou diferença estatisticamente significatova na anteversão acetabular entre ambos os grupos, ao passo que o ângulo acetabular setorial posterior mostrou média inferior no grupo afetado / The present study intends to develop a comparative analysis between primary hip osteoarthritis and acetabular positioning through x-ray exams and computed tomographic scans. 13 affected and 8 non-affected patients by degenerative hip disease with no underline causes are recruited within the ambulatory care service of the Institute of Orthopedics and Traumatology of the Hospital of Clinics, São Paulo University Medical School. Their radiographic exams are studied for extracting some parameters named as: acetabular angles, center edge angle, crossover sign, acetabular width and acetabular depth. Tomographic films give information to measure acetabular ante version and acetabular setorial angles. Statistically, there is no significant relationship concerning acetabular ante version within the two groups, although, the posterior acetabular setorial angle shows a lower median value in the osteoarthritic group
177

Comparação do efeito condroprotetor terapêutico da glicosamina em relação à diacereína no modelo experimental de artrose em ratos / A comparison between the therapeutic chondroprotective effects of glucosamine and diacerhein in an experimental model of arthritis in rats

Alex Silva Santiago Lopes 11 December 2006 (has links)
O objetivo do presente estudo é o de comparar funcionalmente ehistologicamente o efeito terapêutico da glicosamina em relação a diacereína no modelo experimental de artrose em ratos. Trinta ratos Wistar foram submetidos a meniscectomia medial do joelho direito. Dez animais receberam 50mg/kg/dia de diacereína a partir do 3o até o 7o mês de pósoperatório (PO), dez animais receberam 40mg/kg/dia de glicosamina e dez animais não receberam nenhuma medicação. Todos foram sacrificados no 7o mês PO. Foram medidos os ângulos de extensão máxima de cada joelho. A análise histológica com hematoxilina-eosina e alcian blue foi feita de cada um dos côndilos tibiais e femorais. Todos os joelhos operados apresentaram amplitude de extensão do joelho mais limitada que o lado contra-lateral (p=0,001), porém os que receberam diacereína apresentavam menor rigidez (p=0,005). Histologicamente, o modelo experimental levou a uma artrose de leve a moderada estatisticamente diferente do joelho contra-lateral não operado (p=0,001). Já os joelhos dos ratos que fizeram uso das medicações não apresentaram diferenças significativas (p=0,3) entre aqueles que tomaram glicosamina e os que fizeram uso da diacereína. As diferenças entre os joelhos operados medicados e não medicados também não foram estaticamente diferentes. Conclusões: O uso terapêutico da diacereína e glicosamina diminuiu a rigidez articular e retardou a progressão da artrose. A diacereína atuou melhor na mobilidade articular do que a glicosamina, porém não houve diferença estatística entre as duas drogas no controle da degeneração articular / The purpose of this study is to compare, based on a functional and histological analysis, the therapeutic effects of glucosamine as compared to diacerhein in an experimental model of arthritis in rats. Thirty Wistar rats were submitted to a medial meniscectomy of the right knee. Ten animals received 50 mg/kg/day of diacerhein from the third through seventh postoperative (PO) months, ten animals received 40mg/kg/day of glucosamine and ten animals received no medication at all. All of these animals were sacrificed during the seventh PO month. The maximum angle of each knee extension was measured. A histological analysis was carried out by hematoxilin-eosin and alcian blue staining of each of the tibial and femoral condyles. All the operated knees presented a more limited range of extension than the non-operated knees (p=0.001), however, the animals that received diacerhein presented less stiffness (p=0.005). Histologically, the experimental model caused a light to moderate arthritis statistically different from the other non-operated knee (p=0.001). No significant differences (p=0.3) were detected between the knees of the rats medicated with glucosamine and those that received diacerhein. The operated medicated knees and non-operated knees also showed no statistical differences. Conclusion: The therapeutic use of diacerhein and glucosamine decreased joint stiffness and delayed the progression of the arthritis. The diacerhein had a more positive effect on joint mobility than the glucosamine, even though there was no statistical difference between the two drugs in controlling the degeneration of the joint
178

Estudo comparativo entre as osteossínteses de tornozelo com implantes convencionais e bioabsorvíveis / Comparative study of osteosynthesis of ankle with conventional and bioabsorbable implants

Guilherme Pelosini Gaiarsa 06 March 2013 (has links)
O padrão ouro no tratamento cirúrgico das fraturas de tornozelo são as sínteses metálicas, sejam de titânio ou aço. Os implantes bioabsorvíveis foram desenvolvidos para evitar o efeito do stress shielding, ou escudo de carga, e a retirada de material de síntese. O uso de materiais absorvíveis é bem documentado, e com bons resultados em grande número de fraturas craniofaciais. O objetivo deste estudo foi comparar os resultados funcionais de fraturas de tornozelo tratadas com placas metálicas e absorvíveis. Os pacientes foram randomizados e seguidos de forma prospectiva em dois grupos, metálico e absorvível. No período pós operatório imediato os pacientes foram imobilizados com tala gessada por uma semana, substituída por órtese removível por mais 4 semanas. Carga parcial foi autorizada com 3 semanas, e carga total com 6 semanas. Dezenove pacientes foram seguidos por nove meses, e avaliados radiográfica e funcionalmente aos 6 e 9 meses. Todos consolidaram entre 8 e 12 semanas. A recuperação funcional foi similar nos dois grupos. Aos 6 meses, três pacientes no grupo metálico queixaram-se de problemas locais, e tiveram seus implantes removidos. Um paciente do grupo absorvível teve uma deiscência da sutura, tratado com boa evolução. Aos 9 meses foi aplicado o escore da AOFAS para todos os pacientes. Os resultados funcionais foram semelhantes nos dois grupos, após a retirada de implante de três pacientes no grupo metálico. Os implantes absorvíveis permitiram resultados clínicos e funcionais semelhantes aos metálicos em fraturas de tornozelo / The current gold standard fixation system for surgical ankle fractures are the metallic implants, steel or titanium made. Resorbable implants have been developed to avoid stress shielding and a new surgery for implant removal, common with metal implants. Use of resorbable implants is well documented in the literature for a range of craniofacial fractures, with good results. The purpose of this study was to compare the outcome of ankle fractures using biodegradable and metal plates. Patients were randomly and prospectively treated with resorbable or metal fixation system. Post-operatively, the ankle was immobilized with a plaster cast for 1 week, removable cast for other 4 weeks. Half and full weight bearing were allowed at weeks 3 and 6. nineteen patients were followed for 9 months. Functional recovery was similar in both groups at 6 and 9 months, three patients in metal group complained implant-related problems, and had their implants removed, and one in resorbable had an acute dehiscence, solved with surgical debridement and closure. At 6 and 9 months, the AOFAS score was applied for all patients. The functional results were similar in both groups. Implant removal was necessary in three patients from the metallic group. The resorbable plate provided qualitatively similar fracture healing results as the metal plate
179

Comparação entre duas soluções de recondicionamento pulmonar em pulmões humanos não-aceitos para transplante em modelo de avaliação e recondicionamento pulmonar ex vivo / Comparison between two pulmonary reconditioning solution in human lungs non-accepted for transplantation with an ex vivo lung assessment and reconditioning model

Lucas Matos Fernandes 18 August 2015 (has links)
INTRODUÇÃO: O transplante pulmonar é terapia reconhecida de tratamento de doenças terminais pulmonares. Os pulmões, entretanto, são muito susceptíveis às transformações hormonais e hidroeletrolíticas ocorridas no doador após a morte encefálica. As baixas taxas de aproveitamento dos pulmões alavancam pesquisas e meios de utilizar pulmões considerados nãoideais. Um desses modelos é o recondicionamento pulmonar ex-vivo concebido por Steen, no qual se utiliza uma solução hiperosmolar (Steen Solution®) para avaliação e melhora dos pulmões doados. Consideramos que o desenvolvimento de uma solução de recondicionamento pulmonar produzida no Brasil seria conveniente aos serviços de transplante e aos pacientes. Foram comparadas a solução de recondicionamento Steen Solution® e uma solução de fabricação nacional em modelo de ex vivo de pulmões humanos não aceitos para transplante, através da avaliação da mecânica ventilatória, hemodinâmica, trocas gasosas e histologia. MÉTODOS: Foram utilizados 16 pulmões de doadores em morte encefálica, considerados inadequados para o transplante pulmonar. Os pulmões foram submetidos à captação habitual e acondicionados sob isquemia fria por 10 horas. Após este período, os pulmões foram designados, por sorteio, para reperfusão com a solução padrão (Steen solution®) ou a solução nacional por 1h em modelo ex vivo. A lesão pulmonar foi estudada através de parâmetros gasométricos, resistência pulmonar e complacência pulmonar. Foram medidos os pesos em três tempos e relação peso úmido/peso seco após a reperfusão para avaliação de edema. A partir de biópsias seriadas era calculado um score de lesão tecidual e grau de apoptose. RESULTADOS: A capacidade de oxigenação foi de 498,00 ± 37,53 mmHg no grupo STEEN e 521,00 ± 55,43 mmHg no grupo SRNac (p = 0,348). A capacidade relativa de oxigenação calculada ao final do recondicionamento foi 501,37 ± 207,77 no grupo STEEN e 470,30 ± 232,41 no grupo SRNac (p=0,782). Os pesos dos pulmões nos três momentos de avaliação foram: início da isquemia: STEEN = 1.026 ± 451 g, SRNac = 745 ± 282 g (p = 0,180); fim da isquemia: STEEN = 998 ± 391 g, SRNac = 738 ± 316 g (p = 0,184); e fim da reperfusão: STEEN = 1.097 ± 526 g, SRNac = 743 ± 248 g (p = 0,163). A relação peso úmido/peso seco foi 3,63 ± 1,26 no grupo SRNac e 2,06 ± 0,28 no grupo STEEN (p = 0,009). A resistência vascular pulmonar foi 787,99 ± 367,23 dina.s.cm-5 no grupo STEEN e 1.026,81 ± 1.112,53 dina.s.cm-5 no grupo SRNac (p = 0,575). A complacência pulmonar média foi 46,75 ± 20,99 mL/cmH2O no grupo STEEN e 49,74 ± 26,11 cmH2O no grupo SRNac (p = 0,809). O Escore de Lesão Pulmonar foi: STEEN = 4,38 ± 1,51 e SRNac = 4,50 ± 1,77 (p = 0,881). O número de células apoptóticas foi: STEEN = 2,4 ± 2,0 cel/mm2 e SRNac = 4,8 ± 6,9 cel/mm2 (p = 0,361). CONCLUSÕES: Os pulmões reperfundidos com a solução de recondicionamento de fabricação nacional apresentaram características morfológicas e funcionais similares aos que foram reperfundidos com a solução STEEN®, apesar do maior edema encontrado no grupo da solução nacional / INTRODUCTION: Lung transplantation is routine treatment of end-stage lung diseases. The lungs, however, are very susceptible to hormonal and electrolyte changes occurred in the donor after brain death. The low recovery rates of the lungs leverage researches and ways to use lungs considered non-ideal. One such model is the lung ex vivo reconditioning designed by Steen, in which using a hyperosmolar solution (Steen Solution®) for evaluation and improvement of donor lungs. We believe that the development of a pulmonary reconditioning solution produced in Brazil would be convenient to transplantation service and patients. Were compared the standard Steen Solution® and a national manufacturing solution in ex vivo model with human lungs not accepted for transplant, through the evaluation of respiratory mechanics, hemodynamics, gas exchange and histology. METHODS: 16 brain-dead donors lungs, considered unsuitable for lung transplantation, were used. The lungs were harvest as usual, packed and stored in cold ischemia for 10 hours. After this period, the lungs were appointed by randomization to reperfusion with the standard solution (Steen Solution®) or national solution for 1 h in ex vivo model. Lung injury was accessed by blood gas parameters, lung resistance and lung compliance. The weights were measured in three times and the after reperfusion wet weight / dry weight ratio for evaluation of edema. The degree of apoptosis and tissue injury score was calculated from serial biopsies. RESULTS: The oxygenation capacity was 498.00 ± 37.53mmHg in STEEN group and 521.00 ± 55.43mmHg in SRNac group (p = 0.348). The relative oxygenation capacity calculated at the end of the reconditioning was 501.37 ± 207.77 in the STEEN group and 470.30 ± 232.41 in the SRNac group (p = 0.782). The weights of lungs in the three stages of evaluation were: onset of ischemia: STEEN = 1,026 ± 451g, SRNac = 745 ± 282g (p = 0.180); end of ischemia: STEEN = 998 ± 391g, SRNac = 738 ± 316g (p = 0.184); and the end of reperfusion: STEEN = 1,097 ± 526g, SRNac = 743 ± 248g (p = 0.163). The wet weight / dry weight ratio was 3.63 ± 1.26 in SRNac group and 2.06 ± 0.28 in STEEN group (p = 0.009). Pulmonary vascular resistance was 787.99 ± 367.23dina.s.cm-5 in STEEN group and 1026.81 ± 1112.53dina.s.cm-5 in SRNac group (p = 0.575). The Lung Injury Score was: STEEN = 4.38 ± 1.51 and SRNac = 4.50 ± 1.77 (p = 0.881). The number of apoptotic cells was: STEEN = 2.4 ± 2.0 cells / mm 2 and SRNac = 4.8 ± 6.9 cells / mm2 (p = 0.361). CONCLUSIONS: The lungs reperfused with national manufacturing reconditioning solution presented morphological and functional characteristics similar to those reperfused with STEEN® solution despite the greater edema found in the group of national solution
180

Potenciais impactos no comércio internacional de biocombustíveis associados à implementação de esquemas de certificação / Potential impacts on international biofuels trade associated with the implementation of certification schemes

Ravagnani, Rachel Marini, 1986- 26 August 2018 (has links)
Orientador: Arnaldo César da Silva Walter / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica / Made available in DSpace on 2018-08-26T06:47:32Z (GMT). No. of bitstreams: 1 Ravagnani_RachelMarini_M.pdf: 2891702 bytes, checksum: 4f634859cc84db4cdd1d466fcb2787d1 (MD5) Previous issue date: 2014 / Resumo: Em virtude do crescente reconhecimento dos impactos adversos que podem ser causados pelo uso intensivo dos derivados de petróleo, os biocombustíveis surgem com o fim de promover soluções para problemas relacionados à redução de emissões de gases de efeito estufa, segurança de suprimento energético e redução da dependência do petróleo e seus derivados. No entanto, em virtude do aumento do consumo dos biocombustíveis, a sustentabilidade na produção da matéria-prima e conversão do produto final passou a ser pressuposto para que o atendimento às questões mencionadas acima fossem, de fato, cumpridas. A preocupação quanto ao estabelecimento de barreiras comerciais em virtude da implementação de esquemas de certificação para atestar o cumprimento aos requisitos de sustentabilidade tem início neste ponto, para os biocombustíveis. Como o mercado internacional de combustíveis renováveis ainda é recente, a avaliação dos impactos econômicos originados por esquemas de certificação torna-se impraticável e, por esta razão foi proposta uma análise comparada à setores mais maduros e experientes em relação aos esquemas de certificação. A fim de realizar tal comparação artigos que descreviam impactos econômicos dos setores de alimentos e produtos florestais madeireiros foram analisados. Do exame realizado, os impactos econômicos havidos em virtude da certificação puderam ser analisados e classificados para que, posteriormente, um paralelo pudesse ser traçado em relação a identificação de potenciais impactos para os biocombustíveis. O potencial dos esquemas de certificação para criação de barreiras comerciais não tarifárias provou-se complexo para a análise e, também, para constatação. Verificou-se que sua formação não pode ser taxativamente definida, dado que diversos fatores e variáveis interferem para tanto. De forma a complementar o estudo conduzido algumas noções de Direito Internacional e Comércio Internacional foram apresentadas. A configuração das barreiras comerciais não tarifárias, no âmbito da Organização Mundial do Comércio, a identificação de suas disposições nos diferentes acordos da OMC e o cabimento da discussão, no que concerne os biocombustíveis, são realizadas. Disputas envolvendo o estabelecimento ou exigência das avaliações de conformidade (certificados) também são apresentadas, tanto para os biocombustíveis quanto para os demais setores estudados, a fim de fornecer um panorama geral de tais exigências considerando o quadro regulatório internacional. As disputas envolvendo biocombustíveis são discutidas de forma mais profunda / Abstract: Due to the growing recognition of the adverse impacts caused by the intensive use of petroleum, biofuels emerge as alternatives to promote solutions to problems related to reducing of greenhouse gases emissions, security of energy supply and reducing dependence on oil and its derivatives. However, due to the increased consumption of biofuels, sustainability in the production of the feedstock and conversion of the final product became a requirement so that the issues mentioned above are fulfilled. The concern regarding the establishment of trade barriers for biofuels due to the settlement of certification schemes that attest compliance with sustainability requirements takes place at this point. As the international market for renewable fuels is still recent, the assessment of economic impacts originated by certification schemes becomes impractical and, for this reason, a compared analysis to more mature and experienced sectors in relation to certification schemes was proposed. In order to accomplish such comparison, articles related with the food and timber sectors, assessing economic impacts were analyzed. From the examination conducted, economic impacts due to certification schemes could be analyzed and classified so that, later, a parallel could be drawn considering the identification of probable impacts for biofuels. The potential of certification schemes to create non-tariff trade barriers proved complex for analysis and for verification. It was found that the creation of trade barriers cannot be categorically defined since many factors and variables interfere. To complement the conducted study some notions of International Law and International Trade are presented. The configuration of non-tariff trade barriers under the World Trade Organization (WTO), the identification of its provisions in several WTO agreements and the pertinence of the discussion regarding biofuels are carried out. Disputes involving the establishment or requirement of conformity assessments (certificates) are also presented for biofuels and for the other sectors studied, in order to provide an overview of these requirements, considering the international regulatory framework. The disputes involving biofuels are discussed in depth / Mestrado / Planejamento de Sistemas Energeticos / Mestra em Planejamento de Sistemas Energéticos

Page generated in 0.1333 seconds