• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 340
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 349
  • 349
  • 218
  • 216
  • 46
  • 35
  • 34
  • 29
  • 26
  • 26
  • 25
  • 24
  • 23
  • 23
  • 22
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
201

"Avaliação e comparação de diferentes tipos de trocadores de calor e umidade" / Evaluation and comparison among different heat and moisture exchangers

Lucato, Jeanette Janaina Jaber 30 June 2005 (has links)
As tarefas de umidificação e aquecimento do ar inspirado podem ser realizadas por meio de trocadores de calor e umidade (HMEs - Heat and moisture exchangers). Os objetivos do nosso estudo são avaliar e comparar a capacidade de umidificação e aquecimento de oito diferentes tipos de HMEs em um modelo experimental com pulmão animal isolado e avaliar o impacto de cada um dos HMEs na ventilação alveolar em um modelo mecânico do sistema respiratório, com adição de CO2 a um fluxo de 0,65L/min. Os níveis de umidade e temperatura foram medidos durante a situação controle (nenhum HME) e com os diferentes HMEs quando volume corrente; freqüência respiratória e fluxo foram variados. A recuperação da umidade absoluta da expiração durante a próxima inspiração (% RAH) foi calculada. A % RAH aumentou com o uso do HME comparado ao controle. O volume corrente teve um significante efeito na % RAH, o que não ocorreu com alterações na frequência respiratória ou fluxo. O aumento do ETCO2 foi proporcional ao aumento do espaço morto dos HMEs. As alterações de fluxo ou a saturação dos HMEs não determinaram relevantes alterações no ETCO2 / When tracheal intubation is necessary during ventilatory support, the physiological mechanisms of heating and humidifying the inspired air are supressed, so it is vital the preconditioning of the inspired gases with the goal of offering water and heat contents similar to those normally provided by the upper airways. These tasks of humidification and heating can be accomplished through the use of heat and moisture exchangers (HMEs). Objectives: 1- Evaluate and compare the humidification and heating capacity of eight different types of HMEs in a respiratory system analog using preserved swine lung. 2- Evaluate the impact of each one of the tested HMEs over alveolar ventilation in a mevhanical model of the respiratory system
202

"Endotelização in vivo das biopróteses cardíacas porcinas: comparação entre a preservação convencional e a não-aldeídica" / In vivo endothelialization of conventional and non-aldehyde-fixed porcine bioprostheses: comparative study

Nina, Vinicius José da Silva 12 November 2003 (has links)
O revestimento completo das superfícies das biopróteses cardíacas por uma camada protetora de células endoteliais do hospedeiro ainda não foi relatado. As próteses cardíacas de uso corrente são comumente preservadas em glutaraldeído, o qual é citotóxico para as células do hospedeiro evitando a endotelização espontânea. O objetivo deste estudo é demonstrar o potencial para a endotelização in vivo das próteses cardíacas tratadas por um processo alternativo de preservação tecidual (L-Hydro™). O processo de preservação L-Hydro™ consiste na extração controlada de substâncias antigênicas do tecido valvar e na incorporação de um agente antiinflamatório e anti-trombótico. Sete biopróteses porcinas com suporte tratadas pelo processo L-Hydro™ (grupo teste) e três fixadas em glutaraldeído (grupo controle) foram implantadas na posição mitral de ovelhas jovens. As próteses foram avaliadas pela ecocardiografia e angiografia antes do sacrifício aos cinco meses. As próteses explantadas foram avaliadas quanto ao aspecto radiológico, histológico e histoquímico. O teste-t não-pareado de Student e o teste exato de Fisher foram utilizados para a análise estatística. Não houve diferença hemodinâmica entre os grupos, exceto pela pressão capilar mais elevada no grupo controle. Entretanto, a microscopia óptica e a eletrônica de varredura e transmissão mostraram o revestimento quase completo de células endoteliais na superfície de todos os folhetos das próteses tratadas pelo L-Hydro™ após cinco meses de implante. As células endoteliais estavam em contato direto com a camada do colágeno subjacente e expressaram antígenos ligados ao fator von Willebrand. As superfícies das próteses tratadas pelo glutaraldeído encontravam-se cobertas por depósitos de fibrina, macrófagos, cálcio e material trombótico. Apenas células endoteliais esparsas foram observadas neste grupo, e o contato destas células com o colágeno subjacente foi incompleto. Estes dados indicam que a preservação tecidual não-aldeídica (L-Hydro™) utilizada neste estudo é capaz de induzir a endotelização espontânea evidenciada pela boa adesividade celular do novo endotélio à matriz do colágeno, e pela maior resistência à trombose e à calcificação. / A protective layer of endothelial cells of host origin on the entire surfaces of bioprosthetic heart valves has never been reported. Current commercial bioprosthetic heart valves are commonly preserved in glutaraldehyde which is cytotoxic to host cells preventing spontaneous endothelialization. The aim of this study is to demonstrate the potential for in vivo endothelialization of heart valves treated by an alternative tissue preservation process (L-Hydro). L-Hydro preservation process consists of controlled extraction of antigenic substances from the valvular tissue and incorporation of an anti-inflammatory and a anti-thrombotic agent. Seven stented porcine heart valves treated by the L-Hydro™ process (test group) and three glutaraldehyde-fixed porcine heart valves (control group) were implanted in the mitral position of juvenile sheep. The valves were evaluated echocardiographically and angiographically prior to sacrifice at five months. Recovered valves were also radiologically, histologically and histochemically evaluated. Unpaired t-test of Student and Fisher’s exact test were performed for statistical analysis. There were no hemodynamic differences between groups except for a higher pulmonary artery wedge pressure in the control group. However, optical microscopy, scanning and transmission electron microscopy showed a nearly complete coverage of endothelial cells on the surfaces of all leaflets in the L-Hydro™ treated valves after five months of implantation. The endothelial cells were in direct contact with the underlying collagen layer and expressed von Willebrand-related antigens. The surfaces of the glutaraldehyde-treated valves were covered by fibrin deposition, macrophages, calcium and thrombotic material. Only sparse endothelial cells were observed in this group, and contact of the endothelial cells with the underlying tissue was incomplete. These data indicate that the non-aldehyde tissue preservation (L-Hydro) utilised in this study is capable of inducing spontaneous endothelialization with evidence of strong cell attachment of the new endothelium to the collagen tissue matrix, and it also provides a greater resistance to thrombosis and calcification.
203

Estudo comparativo, em cadáveres, da determinação dos pontos isométricos para a reconstrução do ligamento cruzado anterior do joelho com e sem navegação / Surgery computer assisted, Anterior cruciate ligament/surgery, Comparative study, Cadaver, Knee/surgery, Arthroscopy

Angelini, Fabio Janson 11 February 2009 (has links)
INTRODUÇÃO: A precisão no posicionamento dos túneis ósseos na reconstrução do ligamento cruzado anterior do joelho (LCA) é considerado um dos fatores fundamentais para o bom resultado dessa cirurgia. A cirurgia ortopédica auxiliada por computador (computer aided orthopedic surgery CAOS) é um avanço tecnológico que tem como um dos principais objetivos exatamente o aumento da precisão. OBJETIVO: comparar o posicionamento do centro dos túneis e a isometria do enxerto obtidos com o uso de um sistema de navegação computadorizada (Orthopilot) e com o uso de guias cirúrgicos convencionais. MÉTODOS: 36 joelhos pareados de cadáveres tiveram o LCA ressecado por artroscopia no Laboratório de Artroscopia do Departamento de Ortopedia e Traumatologia da Faculdade de Medicina da Universidade de São Paulo. Um joelho de cada par foi ramdomizado para o grupo 1 (guias cirúrgicos convencionais) e o outro para o grupo 2 (Orthopilot). Um fio de sutura inelástico foi passado pelo centro dos túneis tibial e femoral confeccionados para a reconstrução do LCA, sem que os túneis fossem finalmente brocados. Todos os joelhos foram então analisados quanto ao posicionamento do centro do túnel tibial (distância do LCP, distância da tubérculo intercondilar medial da tíbia e distância do corno anterior do menisco lateral), do centro do túnel femoral (distância da cortical posterior e angulação coronal na fossa intercondilar do fêmur) e a variação da distância entre os pontos centrais do túnel femoral para o túnel tibial em flexão de 90º e em extensão (isometria). Os dados foram analisados segundo o teste de Wilcoxon para comparação de duas amostras pareadas. RESULTADOS: A variação da distância entre o tunel femoral e tibial em flexão e extensão (isometria) foi maior no grupo 1 convencional, do que no grupo 2 Orthopilot (grupo 1: média 4,2mm com intervalo de 1,1mm a 9,4mm versus grupo 2: média 2,8mm com intervalo de 0,3mm a 6,7mm; p<0,05). Os outros parâmetros analisados não tiveram diferença estatística entre os grupos e demonstraram que todos os túneis dos dois grupos estavam bem posicionados de acordo com os critérios adotados. CONCLUSÕES: O emprego de instrumental cirúrgico navegado pelo sistema Orhtopilot permitiu o posicionamento dos túneis ósseos da reconstrução do LCA de maneira tão precisa quanto os guias cirúrgicos convencionais utilizados. Mais do que isso, proporcionou um posicionamento significativamente mais isométrico nessa série / INTRODUCTION: Precise tunnel location has been considered to be very important to achieve good results in anterior cruciate ligament (ACL) reconstruction surgery. Computer Aided Orthopedic Surgery (CAOS) is a technology improvement whose main objective is to enhance precision. PURPOSE: To compare the accuracy of tunnel placement and graft isometry for ACL reconstruction performed with the use of a computer-assisted navigation system (Orthopilot) and with traditional instruments. METHODS: 36 matched-paired cadaveric knees had their intact ACL removed by arthroscopy at the Arthroscopy Laboratory Orthopedic Department of University of São Paulo Medical School. One knee of each pair was randomized to group 1 (traditional instruments) or group 2 (Orthopilot). An inelastic suture was then passed through the center of where would be the tibial tunnel and then through the center of where would be the femoral tunnel. None of the tunnels were actually drilled. All knees were then dissected and 6 parameters were obtained: The distance from the tibial tunnel center to: 1) the PCL; 2) the lateral meniscus anterior horn; 3) the medial tibial spine. 4) The distance from the femoral tunnel center to the posterior femoral cortex. 5) The femoral tunnel coronal angle. 6) The variation of the distance from the femoral to the tibial tunnels with the knee extended and in 90 degree flexion. The data were submitted to statistical analysis and compared with the Wilcoxon Matched Pairs Test. RESULTS: The variation of the distance from the femoral to the tibial tunnels in flexion and extension was smaller in the Orthopilot group (better isometry): group 1: mean 4.2 mm (1.1-9.4 mm); group 2: mean 2.8 mm (0.3-6.7 mm) p<0,05. All other parameters showed no statistical difference between the groups and all tunnels were considered to be in satisfactory positions. DISCUSSION: There was no difference in tunnel position between the groups. Better isometry was achieved in the Orthopilot group compared to conventional instruments
204

Influência da espessura corneana na acuidade visual corrigida após transplante de córnea endotelial lamelar profundo (TCELP) / The influence of corneal thickness in visual acuity after deep lamellar endothelial keratoplasty (DLEK)

Marcon, Alexandre Seminoti 07 November 2006 (has links)
Objetivo: Analisar a influência da espessura corneana central na acuidade visual (AV) corrigida após transplante de córnea endotelial lamelar profundo (TCELP). Métodos: Foram estudados de forma prospectiva 155 olhos de 127 pacientes portadores de ceratopatia bolhosa ou distrofia endotelial de Fuchs no sexto mês de pós-operatório do TCELP, entre março de 2000 e março de 2005. Foram excluídos pacientes com outras alterações oculares que justificassem baixa AV. Todos os pacientes foram submetidos à avaliação oftálmica, quando foram determinadas AV corrigida, por meio de exame refratométrico, e espessura corneana central, através da paquimetria ultra-sônica. As técnicas usada foram previamente descritas. Os olhos foram agrupados de acordo com as medidas de AV: grupo I (20/20 - 20/30), grupo II (20/40 - 20/50), grupo III (20/60 - 20/80), grupo IV (20/100 - 20/400). Para correlação com paquimetria e análise estatística, as medidas de AV foram convertidas da tabela de Snellen para a tabela logarítmica (logMAR). Foram criadas variáveis categóricas para expressar status de faixa de normalidade de espessura corneana (entre 495 e 651 ?m), usando como pontos de corte valores encontrados na literatura. Resultados: A média, o desvio padrão e a variação da paquimetria foi: grupo I (n=38) 571 ±80 um, 408 a 784 um; grupo II (n=79) 598 ±80 um, 437 a 816 um; grupo III (n=30) 605 ±99 um, 454 a 945 um e grupo IV (n=8) 607 ±120 ?m, 410 a 781 ?m. Analisando o resultado da AV e a porcentagem de casos com espessura corneana acima de 651 um, foi observada associação linear significativa (P=0,037; ?2 de tendência linear) entre o aumento da paquimetria e a piora da AV. Analisando a associação entre os grupos de AV e a porcentagem de casos com espessura corneana abaixo da faixa de normalidade (<495 um), não foi encontrada significância estatística (P=0,92; x2 de Pearson). Quando analisado o resultado visual do grupo I em relação ao resultado dos grupos II+III+IV em conjunto, observou-se que somente 13% dos casos do grupo I e 30% dos casos dos demais grupos apresentaram espessura corneana maior do que 651 ?m. Essa correlação demonstrou significância estatística limítrofe (P=0,066; x2 de Pearson com correção de Yates). Conclusão: Observou-se associação linear significativa entre piora da AV corrigida e aumento da espessura corneana central. Quando analisados somente casos com paquimetria abaixo da faixa de normalidade, não foi observada associação significativa entre piora da AV corrigida e espessura corneana central / Purpose: To analyze the influence of central corneal thickness in the corrected visual acuity (VA) after deep lamellar endothelial corneal keratoplasty (DLEK). Methods: Retrospective study of 155 eyes of 127 patients 6 months post-op DLEK between March 2000 and March 2005. These patients had been previously diagnosed with either bullous keratopathy or Fuch\'s endothelial dystrophy. Patients with other ophthalmic conditions that could cause loss of vision were excluded. All patients underwent ophthalmic evaluation to determine corrected VA by means of refraction and central corneal thickness by means of ultrasonic pachymetry. Eyes were grouped according to visual acuity into 4 groups: I (20/20 - 20/30), II (20/40 - 20/50), III (20/60 - 20/80), IV (20/100 - 20/400). For statistical analysis and corelation with pachymetry, VA measurements were converted to logMAR. Categorical variables were created to express normal range corneal thickness status (from 495 to 651 um) using values published on the literature. Results: Mean and standart deviation pachymetry values were: group I (n=38) 571 ±80 ?m, ranging from 408 to 784 um; group II (n=79) 598 ±80 um, ranging from 437 to 816 ?m; group III (n=30) 605 ±99 um, ranging from 454 to 945 um and group IV (n=8) 607 ±120 um, ranging from 410 to 781 ?m. Analyzing the VA results and the percentage of cases with corneal thickness above 651 um, a significant linear correlation between higher pachymetry and worse VA was observed (P=0.037; linear trend). Analyzing the association between the different groups and the percentage of cases with corneal thickness bellow 495 um, there was no statistical significance (P=0.92; Pearson\'s x2). When analyzing the visual results of group I compared to groups II+III+IV together, it was observed that only 13% of group I cases and 30% of cases from the other groups presented corneal thickness greater then 651 um. This correlation showed borderline statistical significance (P=0.066; Pearson\'s x2 with Yates\' correction). Conclusions: A significant linear correlation between increased corneal thickness and worse VA was observed. When analyzing only cases bellow normal pachymetry, there was no correlation between corneal thickness and worse VA
205

Perfil de risco cardiovascular de crianças e adolescentes com vírus da imunodeficiência humana/síndrome da imunodeficiência adquirida: estudo PERI / Cardiovascular risk profile in children and adolescents with human immunodeficiency virus/acquired immune deficiency syndrome: PERI study

Giuliano, Isabela de Carlos Back 01 June 2007 (has links)
INTRODUÇÃO: Com a evolução da terapêutica para a Síndrome da Imunodeficiência Adquirida e o conseqüente aumento da sobrevida, um número crescente de crianças e adolescentes passou a conviver com a infecção pelo vírus da imunodeficiência humana (VIH). Paralelamente, aumentou a prevalência de complicações da doença sendo que as cardiovasculares são as mais graves. O presente estudo teve por objetivo determinar a prevalência das alterações cardiovasculares em crianças e adolescentes soropositivas, comparando com soronegativas e a sua relação com variáveis sócio-demográficas e clínicas. MÉTODOS: Estudo observacional, transversal, do tipo caso-controle de 83 crianças e adolescentes soropositivas do ambulatório de infectologia do Hospital Infantil Joana de Gusmão (Florianópolis, Santa Catarina) comparada a 83 crianças e adolescentes soronegativas e aparentemente saudáveis. Foi aplicado questionário estruturado, foram realizados pesquisa em prontuários, exame físico e antropométrico, eletrocardiografia, radiografia de tórax, ecocardiografia e ultra-sonografia carotídea e foi coletado sangue para análises. Foram realizadas análises univariadas e bivariadas para determinação de diferenças entre os grupos e multivariadas por regressão logística, pelo método anterógrado condicional, para os desfechos VIH+, disfunção de ventrículo esquerdo e aumento da espessura médio-intimal carotídea. RESULTADOS: Alterações cardiovasculares foram encontradas em 88% das crianças e adolescentes soropositivos sendo que 31% delas apresentaram mais de duas alterações. Todas as crianças e adolescentes soropositivas apresentaram ao menos um fator ou marcador de risco para aterosclerose, sendo que 68% delas apresentaram mais de dois destes fatores. Após a análise multivariada, a condição VIH+ apresentou associação positiva com tempo de aceleração pulmonar diminuído [razão de chance (RC): 23,9(2,8-204,6), p = 0,004], espessamento médio-intimal [RC: 13,1(3,9-43,5), p < 0,001], proteína C reativa elevada [RC: 11,5(2,8-47,6), p = 0,001] e negativa com excesso de ingestão de gorduras saturadas [0,2(0,1-0,5), p = 0,001]. O espessamento médio-intimal associou-se positivamente com o uso de estavudina [RC: 18,9(2,5-145,6), p = 0,005], aumento da relação átrio esquerdo/aorta [RC: 15,6(1,6-154,6), p = 0,019], aumento de prega suprailíaca [RC: 7,9(1,5-41,9), p = 0,015], taquipnéia [RC: 5,9(1,2-29,3), p = 0,031], níveis elevados de linfócito T CD8+ [RC: 5,7(1,1-28,3), p = 0,033], baixos níveis de linfócito T CD4+ [RC: 5,5(1,2-24,6), p = 0,025]. Por outro lado, associou-se negativamente com níveis elevados de colesterol total [RC: 0,22(0,1-0,8), p = 0,025] e zênite de linfócito T CD8+ [RC: 0,1(0,1-0,5), p = 0,007]. A disfunção de ventrículo esquerdo associou-se positivamente à carga viral detectável [RC: 18,6(3,1-111,6), p = 0,001], ingestão de bebida alcoólica [RC: 10,7(1,7-66,5), p = 0,011], baixo peso ao nascimento [RC: 5,6(1,2-24,7), p = 0,025] e negativamente a veias proeminentes de membros superiores [RC: 0,15(0,03-0,7), p < 0,001]. CONCLUSÕES: Na amostra estudada, as crianças e adolescentes apresentaram altas prevalências de anormalidades cardiovasculares, assim como de fatores de risco para aterosclerose. Estas alterações encontradas, em especial as relacionadas a alterações vasculares precoces da aterosclerose, por sua forte associação com pior prognóstico cardiovascular, indicam a necessidade imediata de formulação de estratégias para seu controle / INTRODUCTION: The Highly Active Anti-Retroviral Therapy employed to acquired immunodeficiency syndrome treatment has increased survival rate of children and adolescents living with human immunodeficiency virus (HIV). The new concerns in this population are infection-related or drug-related complications, and the higher risk complications may be determined by cardiovascular involvement. This study aimed to determine cardiovascular abnormalities prevalence in HIV-infected children and adolescents, and associations among these abnormalities and socio-cultural and clinical variables and cardiovascular risk factors, when compared to HIV-negative children and adolescents. METHODS: An observational, cross-sectional, case-control study was carried out, comparing 83 HIV-infected children and adolescents from an outpatient ambulatory of infectology at Joana de Gusmão Childrens Hospital (Florianopolis, Santa Catarina State) and 83 healthy children from a cardiologic triage outpatient ambulatory, at the same hospital, without any cardiovascular structural abnormality. A questionnaire, research of clinical records, physical examination, anthropometry, electrocardiography, chest X-ray, echocardiography and carotid ultrasound examination were performed and fasting blood sample were collected. Student t, chi-square, Mann-Whitney and Fischer exact tests were performed for univariate and bivariate analysis. For the multivariate analysis, a logistic regression was applied by forward conditional method, to the outcomes HIV-positive, left ventricular dysfunction and thicken intima-media complex. RESULTS: Cardiac abnormalities were found in 88% of the HIV-infected children and adolescents, and in 31% of them there were more than 2 abnormalities. Atherosclerotic risk factors were found in all HIV-infected children and adolescents, and in 68% of them there were more than to risk factors. After multivariate analysis, HIV-infection were positively associated with low pulmonary artery systolic acceleration time [odds ratio (OR): 23.9(2.8-204.6), p = 0.004], thicken carotid intima-media complex [OR: 13.1(3.9- 3.9-43.5), p < 0.001], high C-reactive protein levels [OR: 11.5(2.8-47.6), p = 0.001] and negative association with excessive ingestion of saturated fat [OR: 0.2(0.1-0.5), p = 0.001]. The presence of thicken intima-media complex were positively associated with stavudine use [OR: 18.9(2.5-145.6), p = 0.005], high left atrium/aorta relation [OR: 15.6(1.6-154.6), p = 0.019], high suprailiac skinfold thickness [OR: 7.9(1.5-41.9), 0.015], tachypnea [5.9(1.2-29.3), p = 0.031], high CD8+ T cells count [OR: 5.7(1.1- 28.3), p = 0.033], low CD4+ T cells count [OR: 5.5(1.2-24.6), p = 0.025], and negatively associated with total cholesterol [OR: 0.22(0.1-0.8), 0.1-0.8), p = 0.025] and zenith of CD8+ T cells [OR: 0.1(0.1-0.5), p = 0.025]. Left ventricular dysfunction had a positive association with detectable HIV viral load [OR: OR: 18.6(3.1-111.6), p = 0.001], alcohol ingestion [OR: 10.7(1.7-66.5), p = 0.011], and low birthweight [OR: 5.6(1.2-24.7), p = 0.025] and a negative association with arms prominent veins [OR: 0.15(0.1-0.7), p < 0.001]. CONCLUSIONS: In this sample, we found high prevalence of cardiovascular abnormalities and atherosclerotic risk factors. These abnormalities, especially early cardiovascular markers of atherosclerosis, because are related to a poor cardiovascular prognosis, pointed that there is an urgent necessity to implement preventive strategies to control cardiovascular events in this population, in the next decades
206

Correlação entre a ressonância magnética e a ultra-sonografia com duplex scan colorido no diagnóstico da trombose venosa profunda dos membros inferiores / Correlation between magnetic resonance and duplex color sonography in diagnosis of deep venous thrombosis in lower limbs

Andrade Neto, Flávio Mendes de 07 May 2007 (has links)
A trombose venosa profunda é uma doença que acomete o sistema venoso profundo, com formação de trombos dentro de uma veia e conseqüente reação inflamatória do vaso. O trombo pode determinar a obstrução parcial ou total do vaso. Ocorre em maior número nos membros inferiores e pelve. O quadro normalmente é agudo, mas pode se tornar crônico, com recidivas. Na maior parte dos casos, acomete os membros de forma unilateral. No presente estudo, foram utilizados dois métodos de diagnóstico por imagem na detecção de trombose venosa profunda, que foram a ultra-sonografia em escala de cinza (modo B) associada ao Duplex Scan colorido, e a ressonância magnética. Neste último, foi utilizado meio de contraste paramagnético (Gadolínio) através de administração venosa pediosa. Foram estudados um total de 26 pacientes, 47 membros inferiores e 141 segmentos corporais. A comparação entre os métodos de imagem foi feita por segmento venoso e por segmento corporal. O objetivo do estudo foi avaliar a concordância diagnóstica entre os métodos e a confiabilidade interobservadores nos exames de ressonância magnética, bem como avaliar a sensibilidade, especificidade e acurácia do Duplex Scan colorido em relação à ressonância magnética por segmentos venosos e corporais. Como conclusões do estudo, notamos que houve boa correlação entre a ultrasonografia e a ressonância magnética nos segmentos femorais comuns e superficiais, perfurantes da coxa, poplíteas, tibiais posteriores, fibulares e ilíacas externas. Também houve boa correlação entre os métodos na avaliação das coxas e pernas, e ausência de correlação significativa na pelve. Houve boa confiabilidade interobservadores nos exames de ressonância magnética por segmento venoso. A sensibilidade da ultrasonografia em relação à ressonância magnética foi excelente na pelve, coxas e pernas, sendo a especificidade e acurácia altas na coxa e perna, e baixas na pelve / Deep venous thrombosis is a disease that occurs in deep venous system, with thrombi formation into a vein, and consequent vascular inflammatory reaction. This thrombus can determine partial or total vascular occlusion. It occurs mostly in the lower limbs and pelvis. Clinical presentation is usually acute, but may also be chronic with relapses. In most cases, limb disease is unilateral. In the present study, two different imaging techniques were used in the diagnosis of deep venous thrombosis: B-mode sonography with duplex color Doppler and magnetic resonance imaging with pedal vein administration of paramagnetic contrast media. Twenty-six patients, 47 lower extremities and 141 body segments were evaluated. Comparasion between techniques was made by vascular segments and body segments.The objectives of the study were to evaluate agreement in diagnosis between methods by vascular and body segments, interobserver reliability to read magnetic resonance exams, and sensibility, specificity and accuracy of duplex color sonography in relation to magnetic resonance imaging by vascular and body segments. In conclusion, there was a good correlation between ultrasound and magnetic resonance imaging at common and superficial femoral vein segments, thigh perfurants, calf veins, posterior tibial, fibular and external iliac veins. There was a good correlation between techniques in the evaluation of thighs and legs, but not in the pelvis. There was a good interobserver reliability in the evaluation of vascular segments by magnetic resonance imaging. The sensibility of duplex color sonography in relation to magnetic resonance imaging was excellent in pelvis, thighs and legs; specificity and accuracy were high in thighs and legs, and low in the pelvis
207

Estudo morfométrico comparando duas alternativas de reconstrução da via de efluxo venoso do enxerto no método piggyback de transplante de fígado / Morphometric study comparing two methods of hepatic venous outflow reconstruction in piggyback liver transplantation

Coelho, Fabricio Ferreira 12 February 2007 (has links)
INTRODUÇÃO: No método piggyback de transplante de fígado (Tx), o pinçamento da veia cava inferior (VCI) do receptor é apenas parcial, permitindo a manutenção do retorno venoso durante a fase anepática sem a necessidade de utilização de desvio veno-venoso. A essa vantagem, contrapõe-se uma maior incidência de obstrução da drenagem venosa do enxerto, complicação que está relacionada com o tipo de reconstrução empregado. A implantação da VCI do enxerto no óstio das veias hepáticas média e esquerda (ME) do receptor tem sido evitada devido a uma maior freqüência de bloqueio venoso. Essa incidência diminui quando são empregadas a anastomose látero-lateral (LL) ou a implantação da VCI do enxerto no óstio das veias hepáticas direita, média e esquerda (DME) do receptor. Entretanto, essas reconstruções reduzem a eficiência do retorno venoso na fase anepática do Tx devido à constrição mais pronunciada da VCI durante o pinçamento necessário para a confecção da anastomose. A alternativa de utilizar o óstio formado pelas veias hepáticas direita e média (DM) pode propiciar uma constrição menor da VCI. Entretanto, esse benefício só se justifica se a via de efluxo venoso obtida não apresentar restrições anatômicas. O objetivo deste trabalho é comparar a congruência do perímetro da VCI com o perímetro das bocas anastomóticas e dos óstios de drenagem na VCI, obtidos por meio da utilização das modalidades DM e DME para a reconstrução do efluxo venoso no Tx piggyback. MÉTODO: Foram estudados prospectivamente 16 cadáveres frescos. Após a hepatectomia total, realizou-se o estudo morfométrico da confluência hepatocaval aferindo-se o perímetro da VCI (PVCI) e, nas reconstruções DM e DME, o perímetro das bocas anastomóticas (PDM e PDME) e dos óstios de desembocadura na VCI (PoDM e PoDME). Foram obtidas imagens digitalizadas de todos os perímetros. As medidas foram realizadas por meio do programa analisador de imagens KS300. A análise estatística foi realizada por meio de análise de variância (ANOVA) para medidas repetidas. Utilizou-se um nível de significância de 5%. RESULTADO: Foram estudados 11 casos do sexo masculino (68,8%). A média de idade foi de 63,7 ± 15,7 anos (40 a 83 anos). Foram obtidos dados completos para todas as variáveis, exceto para o PoDME. Os valores de PDME (137,2 ± 24,3 mm; p<0,001), PDM (123,2 ± 20,1 mm; p=0,003) e PoDM (116,6 ± 17,5 mm; p=0,027) foram significantemente maiores do que o PVCI (107,9 ± 18,8 mm). Os valores de PDME foram significantemente maiores que os de PDM (p=0,004) e PoDM (p=0,001). CONCLUSÃO: A via de efluxo venoso da modalidade DM apresenta um perímetro maior que o da VCI tanto no ponto de anastomose quanto no óstio de desembocadura na VCI, não determinando restrições anatômicas para o efluxo venoso do enxerto hepático. Em comparação com a modalidade DME, a modalidade DM apresenta perímetro mais congruente com o da VCI. / INTRODUCTION: In piggyback liver transplantation (LT), partial clamping of the recipient inferior vena cava (IVC) preserves the venous return of the lower extremities during the anhepatic phase precluding the use of venovenous bypass. The incidence of hepatic venous outflow obstruction after piggyback LT varies according to the type of venous reconstruction. Anastomosis between the cranial portion of the graft IVC and common stump of the middle and left hepatic veins (ME) of the recipient has been avoided due to a higher frequency of hepatic venous outflow obstruction. This incidence decreases when a cavo-caval side-to-side anastomosis (SS) or the ostium of the three main hepatic veins of the recipient (RML) are used. On the other hand, venous return is reduced in these modalities due to a more pronounced constriction during the IVC clamping. The use of the ostium formed by the right and middle hepatic veins (RM) may limit IVC constriction. However, this benefit is only justified if a hepatic venous outflow tract with no anatomical restrictions can be obtained. The aim of this study is to compare the congruence of the IVC perimeter with the perimeter of the venous outflow tract at the anastomotic site and also its opening into the IVC both in the RM and RML modalities. METHODS: Sixteen fresh human cadavers were prospectively studied. After total hepatectomy, a morphometric study of the hepatocaval confluence was done by measuring the perimeter of the IVC (IVCP) and, in RM and RML reconstructions, the perimeter of the venous outflow tract at the anastomotic site (RMP and RMLP) and at its opening into the IVC (RMoP and RMLoP). Digital images of all perimeters were obtained. The measurements were accomplished utilizing the KS300 image analysis software. The statistical analysis was performed using analysis of variance (ANOVA) for repeated measures. Statistical significance was established when the p value was less than 0.05. RESULTS: Examinations were performed in 11 men and 5 women with a mean age of 63.7 ± 15.7 years (40 to 83 years). Complete data were obtained for all the variables except for RMLoP. The mean RMLP (137.2 ± 24.3 mm; p<0.001), RMP (123.2 ± 20.1 mm; p=0.003) and RMoP (116.6 ± 17.5 mm; p=0.027) values were significantly larger than IVCP (107.9 ± 18.8 mm). RMLP values were significantly larger than RMP (p=0.004) and RMoP (p=0.001). CONCLUSION: In RM reconstruction, the venous outflow tract presents a larger perimeter than IVC both at the anastomotic site and at the opening into IVC. In comparison to RML, the RM modality presents a more congruent perimeter with the IVC.
208

Vagar e navegar: pelo mar de Melville e o sertão de Rosa. Estudo Comparativo entre Moby-Dick e Grande Sertão: veredas / Wander and browse: by Melville´s sea and the backlands of Rosa: a comparative study of Moby-Dick and The Devil to Pay in the Backlands.

Viviane Cristine Calor 10 August 2011 (has links)
Embora haja um intervalo de mais de um século entre a publicação de Moby-Dick (1851) e a de Grande sertão: veredas (1956), o romance de João Guimarães Rosa apresenta, quer na forma, quer no conteúdo ou em seus respectivos desdobramentos alegóricos, muitos pontos em comum com o livro de Herman Melville. Produtos de literaturas periféricas de países ainda em processo de formação, essas obras são narrativas híbridas que não se encaixam na concepção original do romance moderno europeu (ou novel): ambas resgatam e transformam a épica e a tragédia, os chamados gêneros altos, para dar voz a um indivíduo que, à margem da sociedade de seu tempo, erra por um vasto espaço inóspito enquanto empenha-se em combates mortais. O propósito deste estudo é analisar, sob um ponto de vista comparativo, passos de Moby-Dick e Grande sertão: veredas, divididos de acordo com os gêneros literários que abarcam e, destacando semelhanças e diferenças, propor Moby-Dick, livro que Guimarães Rosa tinha em sua biblioteca pessoal, como uma das fontes inspiradoras do Grande sertão. / Although written more than a century apart, American Herman Melvilles Moby-Dick (1851) and Brazilian João Guimarães Rosas The Devil do Pay in the Backlands (1956) sharewhether in format, content, and even in their allegorical significancemany common traits. As products of peripheral literatures of countries undergoing a formative process, both are hybrid narratives that do not fit into the original concept of the European novel; their authors resort to, and transform, the so-called high genres, the epic and the tragedy, to give voice to an individual who, at the margin of the society of his time, wanders through a vast and hostile space whilst engaged in lethal combats. In telling his memories, that individual also outlines a survey of the society from which he is excluded, mixing his history with that of his country. The purpose of this study is to examine and compare extracts from Moby-Dick and The Devil to Pay in the Backlands, divided according to the literary genres that both used and transformed, and, by highlighting similarities and differences, identify Moby-Dick, a book that Rosa had in his personal library, as one of the literary sources for The Devil to Pay in the Backlands.
209

SISTEMA DE ATENDIMENTO AOS ADOLESCENTES EM CONFLITO COM A LEI: UM ESTUDO COMPARATIVO ENTRE MOÇAMBIQUE E BRASIL / Care system for children in conflict with the law

Francisco, Tomás Xavier José 24 February 2014 (has links)
Made available in DSpace on 2017-07-21T14:43:12Z (GMT). No. of bitstreams: 1 Tomas Xavier Francisco.pdf: 1542084 bytes, checksum: 8ca03ff0bb912f54bdd68a805807eff7 (MD5) Previous issue date: 2014-02-24 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / This dissertation deals with the system of care for children in conflict with the law, making a comparative study between Mozambique and Brazil, taking as a historic landmark, the constitutional changes brought these two countries in 2004, for the case of Mozambique and in 1988, for the case of Brazil. These constitutional changes meant that subsequently adopt these two countries, an environment conducive to promoting and protecting the rights of the child and adolescent legal framework. This is in general, and more specifically in cases of children in conflict with the law, through a system of care that adequately meets the adolescent offenders. It was in this context that exists in 1990, in Brazil the adoption status of children and adolescents, commonly known as ACE. For the case of Mozambique, a law that can equate to a statute, called the Law for the Promotion and Protection of the Rights of the Child (LPPRC) and the Law of Jurisdictional Organization for Minors, in 2008 approved. The work is structured in three chapters, namely: The first chapter talks about aspects of State, Rule of Law, sovereignty, globalization, fundamental rights and brief approach to Mozambique and Brazil, in terms of geography, political, social and economic. The second chapter presents considerations about the history of the rights of children and adolescents in the world, Mozambique and Brazil; in the third chapter, we addressed properly on the system of care for children in conflict with the law of Mozambique and Brazil. Also work presents conclusions and references. For the preparation of the dissertation, we use as a methodology, descriptive research, preceded by an initial exploratory study and documentary research. / O presente trabalho trata sobre o sistema de atendimento aos adolescentes em conflito com a lei, por meio de um estudo comparativo entre Moçambique e Brasil, tomando como marco histórico as mudanças constitucionais operadas nestes dois países, em 2004, para o caso de Moçambique, e em 1988, para o caso de Brasil. Essas mudanças constitucionais fizeram com que, posteriormente, se adotasse nestes dois países um quadro legal favorável à promoção e proteção dos direitos da criança e do adolescente. Isso ocorre de maneira geral, e mais especificamente naqueles casos de adolescentes em conflito com a lei, através de um sistema de atendimento que atenda adequadamente aos adolescentes infratores. É neste âmbito que se verifica, em 1990, no Brasil, a adoção do Estatuto da Criança e do Adolescente (ECA). Para o caso de Moçambique, é aprovada a Lei de Promoção e Proteção dos Direitos da Criança (LPPDC), a qual pode ser equiparada a um estatuto, e a Lei da Organização Jurisdicional de Menores, no ano de 2008. Para a elaboração desta dissertação, utilizamos como metodologia a pesquisa descritiva, antecedida de um inicial estudo exploratório e pesquisa documental. O trabalho está estruturado em três capítulos, a saber: o primeiro capítulo disserta sobre aspectos relacionados com Estado, Estado de Direito Democrático, soberania, globalização, direitos fundamentais e uma breve abordagem sobre Moçambique e Brasil, em termos geográficos, políticos, sociais e econômicos. O segundo capítulo apresenta considerações sobre a história dos direitos das crianças e dos adolescentes no mundo, em Moçambique e no Brasil. O terceiro capítulo apresenta o sistema de atendimento aos adolescentes em conflito com a lei de Moçambique e Brasil. Por fim, o trabalho traz as considerações finais e as referências bibliográficas utilizadas.
210

Estudo comparativo de duas modalidades de mensuração do refluxo gastroesofágico: pHmetria esofágica convencional e pHmetria sem cateter / Comparative study of two modes of gastroesophageal reflux measuring: conventional esophageal pH monitoring and wireless pH monitoring

Azzam, Rimon Sobhi 02 September 2009 (has links)
A pHmetria esofágica é considerada o melhor método diagnóstico do refluxo ácido gastroesofágico. Contudo, é bastante incômoda e restringe consideravelmente as atividades cotidianas do paciente. A pHmetria sem cateter foi desenvolvida para contornar tais limitações. OBJETIVOS: Comparar as pHmetrias convencional e sem cateter em relação: ao grau de incômodo e limitações das atividades cotidianas, à ocorrência de falhas técnicas relevantes, à capacidade de detecção do refluxo e de relacionar as queixas clínicas com o mesmo. Objetiva-se também, verificar se a monitorização mais prolongada (48 horas) oferece vantagens em relação à monitorização usual (24 horas). MÉTODOS: Foram estudados, de modo prospectivo, 25 pacientes encaminhados para realização de pHmetria esofágica, com sintomas típicos da doença do refluxo gastroesofágico, como queixa predominante. Todos pacientes foram submetidos à entrevista clínica, manometria esofágica e realização, com período inicial simultâneo, de pHmetrias com cateter (24 horas) e sem cateter (48 horas). Foi aplicado questionário para avaliação do grau de incômodo, após o término das pHmetrias. RESULTADOS: Quanto ao incômodo na introdução dos sensores de medida de pH, quinze (60%) pacientes apontaram a cápsula como mais incômoda e dez (40%) o cateter (p=0,327). Durante a monitorização, o incômodo foi menor no segundo dia em relação ao primeiro, em todos os itens do questionário (p<0,05). Houve queda precoce da cápsula em um (4%) paciente e nenhuma falha técnica relevante na pHmetria com cateter (p=0,463). As porcentagens de tempo de refluxo (total, ortostático e supino) foram mais elevadas na pHmetria sem cateter (p<0,05). O Índice de Sintomas foi positivo em 12 (48%) pacientes na pHmetria com cateter e em 13 (52%) na pHmetria sem cateter (p=0,777). O Índice de Sintomas foi positivo em 13 (52%) pacientes na pHmetria por tempo usual (24h) e em 14 (56%) na mais prolongada (48h) (p=1,000). CONCLUSÕES: Nas condições da presente pesquisa: 1) Não há diferença significante entre as duas modalidades de pHmetria, em relação ao grau de incômodo na introdução dos sensores de pH (cápsula X cateter) e nem quanto à ocorrência de falhas técnicas relevantes durante o exame; 2) A monitorização do refluxo pela pHmetria sem cateter é menos incômoda que a com cateter. A pHmetria sem cateter detecta refluxo em porcentagens superiores aos detectados pela pHmetria convencional; 3) Os dois métodos de pHmetria têm capacidades semelhantes de relacionar as queixas clínicas com o refluxo; 4) A monitorização mais prolongada (48h) não proporciona incremento significante na capacidade de relacionar as queixas clínicas com o refluxo, em relação à monitorização por tempo usual (24h). / Esophageal pH monitoring is considered to be the gold standard for the diagnosis of gastroesophageal acid reflux. However, this method is very troublesome and considerably limits the patients routine activities. Wireless pH monitoring was developed to avoid these restrictions. OBJECTIVES: To compare conventional and wireless pH monitoring in relation to: routine activity limitations and degree of discomfort, the occurrence of relevant technical failures, the ability to detect reflux and to correlate the clinical symptoms to it. An additional objective is to determine if longer monitoring (48-hour) offers any advantages over usual monitoring (24-hour). METHOD: Twenty-five patients referred for esophageal pH monitoring and with typical symptoms of gastroesophageal reflux disease as the main complaint were studied prospectively. All patients underwent clinical interview, esophageal manometry and were submitted, with a simultaneous initial period, to 24-hour catheter pH monitoring and 48-hour wireless pH monitoring. After each pH-metry the patients completed a questionnaire on the degree of discomfort. RESULTS: Fifteen (60%) patients reported a higher level of discomfort to introduce the capsule and ten (40%) to introduce the catheter (p=0.327). For all questionnaire items, less discomfort was reported during the second day of monitoring in comparison to the first day (p<0.05). Early capsule detachment occurred in one (4%) case and there were no relevant technical failures with the catheter pH monitoring (p=0.463). Percentages of reflux time (total, upright and supine) were higher with the wireless pH monitoring (p<0.05). The Symptom Index was positive in 12 (48%) patients with catheter pH monitoring and in 13 (52%) with wireless pH monitoring (p=0.777). The Symptom Index was positive in 13 (52%) patients with usual 24-hour pH-metry and in 14 (56%) with longer pH-metry (48-hour) (p=1.000). CONCLUSIONS: Under the conditions of the current research: 1) No significant differences were reported between the two methods of pH monitoring, in relation to the degree of discomfort to introduce the pH sensors (capsule X catheter) or in regard to relevant technical failures; 2) During pH monitoring, the wireless system is better tolerated than the catheter. Wireless pH monitoring detected higher percentages of reflux time than the conventional pH-metry; 3) The two methods of pH monitoring were comparable in correlating the clinical symptoms with the reflux; 4) The longer 48-hour pH monitoring does not significantly improve the ability to correlate the clinical symptoms with the reflux in relation to the 24-hour pH monitoring.

Page generated in 0.1436 seconds