• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 209
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 216
  • 113
  • 67
  • 47
  • 40
  • 27
  • 26
  • 22
  • 22
  • 20
  • 19
  • 16
  • 15
  • 14
  • 14
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
151

Validação de métodos para análise de estatinas em medicamentos por cromatografia líquida de alta eficiência e eletroforese capilar / Validation of methods for analysis of statins in pharmaceutical preparations by high performance liquid chromatography and capillary electrophoresis

Karina Litzi González Tejerina 05 December 2011 (has links)
As estatinas são os fármacos mais usados para tratamento das hiperlipidemias em prevenção primária e secundária, com o propósito de diminuir os níveis de lipoproteínas plasmáticas ricas em colesterol e reduzir os riscos de doença arterialcoronária (DAC) (WITZTUM, 2005). Estes efeitos são resultantes da atividade inibidora das estatinas sobre a enzima HMG-CoA redutase (hidroximetilglutaril-CoA redutase), com a propriedade de bloquear a conversão do substrato HMG-CoA em ácido mevalônico, inibindo os primeiros passos da biossíntese de colesterol. Estas substâncias, (fluvastatina FS, atorvastatina ATC e rosuvastatina RC) são capazes de mimetizar o substrato natural. Podem ser divididas em naturais e sintéticas e diferem fundamentalmente, em termos de potência, perfil farmacocinético, interação farmacológica e efeito indesejado relacionado à miotoxicidade. Na presente pesquisa foram desenvolvidos e validados métodos analíticos de separação (cromatografia liquida de alta eficiência e eletroforese capilar) para cada fármaco. Estes métodos foram aplicados a medicamentos comercializados no Brasil. O método por CLAE foi realizado em coluna LiChrospher® RP-18 (125x4 mm, 5µm) Merck® e uma fase móvel composta por metanol:água (70:30 v/v) para FS e ATC, (60:40 v/v) para RC, com 5 mM trietilamina e pH ajustado para 3.0 com ácido ortofosfórico. O método mostrou boa linearidade (r 0,9915), (LD 2,02 e LQ 6,12) FS; (r 0,9959), (LD 0,44 e LQ 1,34) ATC e (r 0,9945), (LD 1,55 e LQ 4,70) RC. A exatidão foi expressa em porcentagem de recuperação (R% 99,59) FS, (R% 100,24) ATC e (R% 99,2). Pelo método MEKC foi realizado utilizando capilar de sílica fundida de 40,2 cm x 75 m d. i. (30 cm até detector); eletrólito: tampão borato 20 mM: SDS 30 mM: metanol10% v/v pH 9,24; voltagem aplicada: +22 kV; injeção: hidrodinâmica 0,5 psi/3s, apresentaram linearidade (r 0,9997), (LD 0,94 e LQ 2,85) FS; (r 0,9999), (LD 2,36 e LQ 7,17) ATC. A porcentagem de recuperação (R% 104,61) FS, (R% 103,96) ATC. Pelo método CZE foi realizado utilizando sílica fundida de 40,2 cm de cumprimento sendo 30 cm até o detector, 75 µm de d.i. e 375 µm de d.d., eletrólito: tampão tetraborato de sódio 20 mM, pH 9,20; voltagem aplicada: +25kV; injeção: hidrodinâmica 0,5 psi/5s, apresentou linearidade (r 0,9989), (LD 4,92 e LQ 14,91) RC; A porcentagem de recuperação (R% 100,66) RC. / Statins are the drugs most commonly used for treatment of hyperlipidemia in primary and secondary prevention, with the aim of reducing levels of lipoproteins rich in cholesterol and reduce the risk of coronary-artery disease (CAD) (Witztum, 2005). These effects are due to the inhibitory activity of statins on the enzyme HMG-CoA reductase (hydroxymethylglutaryl CoA reductase), with the property to block the conversion of the substrate HMG-CoA to mevalonic acid, inhibiting the first steps of cholesterol biosynthesis. These substances (fluvastatin FS, atorvastatin ATC and rosuvastatin RC) may mimic the natural substrate, can be divided into natural and synthetic, and differ fundamentally in terms of potency, pharmacokinetics, drug interactions and unwanted effects related to muscle-toxicity. In the present study were developed and fully validated analytical methods of separation (high efficiency liquid chromatography and capillary electrophoresis) for each drug. These methods were applied to drugs marketed in Brazil. The method was performed by HPLC column LiChrospher® RP-18 (125x4 mm, 5mm) Merck® and a mobile phase consisting of methanol: water (70:30 v / v) for FS and ATC (60:40 v / v) to RC, with 5 mM triethylamine and pH adjusted to 3.0 with orthophosphoric acid. The method showed good linearity (r 0.9915), (2.02 LD and LQ 6.12) FS; (r 0.9959), (0.44 LD and LQ 1.34) ATC; (r 0.9945), (1.55 LD and LQ 4.70) for RC. The accuracy was expressed as a percentage of recovery (R% 99.59%) FS, (R% 100.24) ATC and (R 99.2%) RC. The MEKC method was performed using a fused silica capillary of 40.2 cm x 75 m d. i. (30 cm to detector); electrolyte: 20 mM borate buffer: 30 mM SDS: metanol10% v / v pH 9.24, applied voltage: +22 kV, injection: hydrodynamic psi/3s 0.5 showed linearity (r 0, 9997), (LQ 0.94 and LD 2.85) FS, (r 0.9999), (LQ 2.36 and LD 7.17) ATC. The percentage recovery (% R 104.61) FS, (R 103.96%) ATC. The CZE method was performed using fused silica of 40.2 cm long and 30 cm to the detector, 75 mm in di and 375 mm in dd, electrolyte: sodium tetraborate buffer 20 mM, pH 9.20, applied voltage: +25 kV, injection: hydrodynamic psi/5s 0.5, showed linearity (r 0.9989), (4.92 LD and LQ 14.91) RC; The percentage recovery (% R 100.66) RC.
152

Avaliação in vitro da liberação, penetração e retenção cutâneas de ciclopirox olamina em formulações de uso tópico por um processo validado / In vitro evaluation of the release, penetration and cutaneous retention of cyclopirox olamine in topical formulations

Daniela Serikaku 13 February 2006 (has links)
Para que um produto de aplicação tópica apresente o efeito terapêutico é necessário que o fármaco seja liberado de seu veículo e atravesse a barreira do estrato córneo, atingindo seus sítios de ação nas camadas da pele nas quais o efeito é esperado. Os estudos de penetração cutânea in vitro, utilizando células de difusão de Franz modificadas, podem fornecer resultados úteis quanto à eficácia do produto. As dermatofitoses são micoses superficiais. São manifestações crônicas e resistentes ao tratamento, fato que se explica não só em decorrência da própria natureza destas afecções como também devido à baixa penetração de fármacos antimicóticos na pele. Dentre os antifúngicos disponíveis na terapêutica, ciclopirox olamina é uma substância que tem demonstrado elevada eficácia no tratamento de dermatofitoses. O presente trabalho teve como objetivo desenvolver formulações de uso tópico contendo 0,5% de ciclopirox olamina e avaliar a performance dessas formulações. Foi possível obter formulações estáveis fisicamente, contendo promotores de penetração cutânea. O sistema de amostragem automática utilizado para realização dos experimentos foi qualificado e apresentou-se em condições adequadas. / In order to present the pharmacological effect, a topical product must release the pharmaceutical active ingredient from its vehicle and this active must pass through the stratum corneum barrier, reaching the target layer of the skin, where its effect is desired. In vitro skin penetration studies, using modified diffusion Franz cells, can provide useful results regarding the product efficacy. Dermatophytosis is superficial mycosis resistant to treatment due to the disease nature and also to the low penetration profile of the antifungals into the skin. Among the antifungals available in the therapeutic arsenal, ciclopirox olamine has demonstrated a high efficacy in the treatment of dermatophytosis. The objectives of the present work were to develop topical formulations containing 0,5% of ciclopirox olamine and evaluate their performance. It was possible to obtain physically stable formulae, containing skin penetration enhancers. The automatic sampling system used in the experiments was qualified, showing adequate performance.
153

Correlação in vitro in vivo para formas farmacêuticas sólidas de liberação modificada contendo diclofenaco de sódio / In vitro-in vivo correlation for sodium diclofenac modified release tablet formulations

Samanta Cardozo Mourão 17 September 2009 (has links)
A correlação in vitro-in vivo (CIVIV) refere-se ao estabelecimento de uma relação racional entre as propriedades biológicas, ou parâmetros derivados destas, produzidos por uma forma farmacêutica e suas propriedades ou características físico-químicas. O estabelecimento desse tipo de correlação de dados pode possibilitar a substituição dos estudos in vivo, necessários à demonstração da bioequivalência, pelos estudos in vitro, no caso de alterações no processo de fabricação pós-registro. Os sistemas matriciais apresentam, como principal exemplo de material controlador da liberação, substâncias poliméricas formadoras de matrizes hidrofílicas. Hidroxipropilmetilcelulose (HPMC) é um excipiente de escolha para o preparo de matrizes hidrofílicas, devido à capacidade de formação de gel e controle da liberação. O diclofenaco de sódio (DCL) é um antiinflamatório não esteroidal com ação analgésica e antipirética. Considerando suas características físico-químicas e farmacológicas, é objetivo deste trabalho o estabelecimento de uma CIVIV para DCL incorporado em sistemas matriciais. Os comprimidos de DCL com HPMC foram desenvolvidos e submetidos aos ensaios de dissolução utilizando os aparatos 1, 2, 3 e 4 conforme as especificações farmacopeicas. Foi realizado o estudo de biodisponibilidade, seguindo as normas éticas, com as formulações selecionadas. A partir dos dados de absorção obtidos pela técnica de deconvolução e dos dados de dissolução foi estabelecida a correlação. Os resultados demonstraram que o aumento da concentração de HPMC produziu a redução da velocidade de dissolução e, dependendo da condição de estudo, estas diferenças foram mais ou menos significativas. Os comprimidos com concentração intermediária de HPMC (15 a 20%) foram mais sensíveis às alterações de formulação e das condições do ensaio de dissolução. As formulações contendo 30% de HPMC praticamente não modificaram o perfil de dissolução, mesmo com alterações na formulação e condições de estudo. No estudo de biodisponibilidade empregado no estabelecimento da CIVIV, foram utilizadas as formulações F1, F2A, F3 e o medicamento de referência Voltaren® 50 mg. A fração absorvida percentual foi determinada pela técnica de deconvolução. A correlação linear entre a fração absorvida e fração dissolvida apresenta um coeficiente de determinação maior do que 0,7. Foi observado que os perfis de dissolução são mais discriminativos que os perfis de absorção, indicando que uma melhor correlação pode ser obtida através da adequação do método de dissolução. / The term in vitro-in vivo correlation (IVIVC) refers to the establishment of a rational relationship between the biological properties, or a parameter derived from a biological property produced by a dosage form, and a physicochemical characteristic or property of the same dosage form. The establishment of IVIVC enables the substitution of in vivo studies for in vitro studies to evaluate bioequivalence, e.g. in case of post-approval changes. Matrix tablets employ mainly hydrophilic polymers to control drug release. Hydroxypropylmethylcellulose (HPMC) is an excipient of choice for preparation of hydrophilic matrices, due to its gel formation and controlled drug release capacities. Sodium diclofenac (SD) is a non-steroidal anti-inflammatory drug with analgesic and antipyretic effects. Considering its physicochemical and pharmacological characteristics, the objective of this work is to establish an IVIVC for HPMC matrix tablets containing SD. HPMC matrix tablets with SD were formulated and submitted to dissolution testing using apparatus 1, 2, 3 and 4 in accordance with pharmacopoeial specifications. The bioavailability study was carried out under ethical guidelines, using the selected formulations. The correlation was obtained by plotting absorption data, obtained from diclofenac plasmatic curves through a deconvolution technique, against dissolution data. The results showed that the increase of HPMC concentration produces a decrease of the drug dissolution rate and these differences were more or less significant, depending on the study conditions. Tablets with intermediate HPMC concentrations (15 to 20%) were more sensitive to changes in dissolution conditions. Formulations containing 30% HPMC do not present changes in dissolution profiles, even when the formulation or the study conditions change. Formulations F1, F2A, F3 and Voltaren® 50 mg as reference product were used in the bioavailability study to establish IVIVC. The linear correlation between absorbed drug fraction and dissolved drug fraction has a determination coefficient higher than 0.7. It was observed that the dissolution profiles are more discriminative than the absorption profiles, which indicates that a better correlation can be obtained through changes of the dissolution method.
154

Validação de metodologias analíticas para determinação quantitativa de princípios ativos em formulações farmacêuticas empregadas para \"peelings\" químicos / Validation of analytical methodologies for quantitative determination of drugs in pharmaceutical formulations employeds to chemical \"peelings\"

Tatiane Rodrigues Ramos 15 June 2004 (has links)
Os \"peelings\" químicos são formulações esfoliantes utilizadas na terapêutica de queratoses actínicas, rugas, discromias pigmentares, acne vulgar e rosácea. A solução de Jessner (SJ) é amplamente usada como agente em peelings químicos. Na presente pesquisa foram empregadas formulações farmacêuticas de SJ como amostras para a determinação quantitativa simultânea das substâncias ativas. A solução alcoólica é composta de resorcinol (14%), ácido salicílico (14%) e ácido láctico (14%). Duas amostras de gel são compostas de resorcinol (30%) e ácido salicílico (20%), respectivamente. Foram desenvolvidos e validados métodos espectrofotométricos na primeira e segunda derivada no UV para a quantificação de ácido salicílico e resorcinol, respectivamente na SJ, utilizando etanol como branco e foram desenvolvidos métodos espectrofotométricos na primeira derivada no UV para a quantificação de resorcinol e ácido salicílico nas amostras em gel, utilizando ácido sulfúrico 0,1 N como branco. Quando o etanol foi utilizado como branco, as curvas de calibração foram lineares em uma faixa de concentração de 22,0 a 34,0 µg/mL (resorcinol) e de 12,0 a 24,0 µg/mL (ácidos salicílico), para os métodos na segunda e primeira derivada no UV (usando etanol como branco), ambos com coeficientes de correlação de 0,9999. Quando o ácido sulfúrico 0,1N foi utilizado como branco, as curvas de calibração foram lineares em uma faixa de concentração de 18,0 a 42,0 µg/mL (resorcinol) e de 8,0 a 32,0 µg/mL (ácido salicílico), para o método na primeira derivada no UV com coeficientes de correlação de 0,9999 e 0,9998 respectivamente. Os resultados nas amostras alcoólicas de SJ (amostras A e B) foram 104,4% de resorcinol (DPR 0,83%) e 103,2% de ácido salicílico (DPR 0,68%) enquanto que nas amostras em gel (amostras E e F) foram 101,9% de resorcinol (DPR 0,34%) e as amostras em gel C e D, 100,7% de ácido salicílico (DPR 0,28%). / Chemical peelings are exfoliating formulations used in the treatment of actinic keratosis, wrinkles, dyschromies, acne vulgaris and rosacea acne.The Jessner Solution (JS) sample is widely used as chemical peeling agent. In this research we selected a JS pharmaceutical preparation for simultaneous quantitative determination of the active components. The alcoholic solution sample is composed of resorcinol (14%), salicylic acid (14%) and lactic acid (14%); two gel samples are composed of resorcinol (30%) and salicylic acid (20%), respectively. First and second derivative UV spectrophotometric methods were developed and validated for quantitative determination of salicylic acid and resorcinol, respectively. In JS alcoholic solution, ethanol was used as background. A first derivative UV spectrophotometric method was developed for quantitative determination of resorcinol and salicylic acid in gel samples using 0.1N sulfuric acid as background. Calibration curves were linear within a concentration range from 22.0 to 34.0 µg/mL (resorcinol) and from 12.0 to 24.0 µg/mL (salicylic acid), for second and first derivative UV spectrophotometric method (ethanol as background) with a correlation coefficients of 0.9999 and 0.9999, respectively. Calibration curves were linear within a concentration range from 18,0 to 42,0 µg/mL (resorcinol) and from 8.0 to 32.0 µg/mL (salicylic acid), for first derivative UV spectrophotometric method (0.1N sulfuric acid as background) with correlation coefficients of 0.9999 and 0.9998, respectively. The alcoholic samples of JS (sample A and B) presented 104.4% of resorcinol (RSD 0.83%) and 103.2% of salicylic acid (RSD 0.68%) while the gel samples (sample E and F) presented 101.9% of resorcinol (RSD 0.34%) and gel sample C and D, 100.7% of salicylic acid (RSD 0.28%).
155

Desenvolvimento e aplicação de eletrodos compósitos impressos à base de grafite e poliuretana / Development and application of graphite and polyurethane screen-printed composite electrodes

Thalita Rocha Saciloto 07 November 2014 (has links)
Um método de fabricação para eletrodos compósitos impressos à base de grafite e resina poliuretana (EIGPU) foi desenvolvido, iniciando-se pela tinta e processo para a impressão, além da otimização dos parâmetros para garantir a aplicabilidade e maximização da resposta dos mesmos. Os parâmetros otimizados na fabricação da tinta foram a composição de 60% grafite e 40% poliuretana (m/m), a natureza e quantidade de solvente, dimensão do conjunto impresso, quantidade de demãos aplicadas no processo de \"screen-printing\", espessura da máscara adesiva e o tipo de isolante que define os contatos elétricos e a área ativa do eletrodo. Também foi proposto e desenvolvido um procedimento de ativação da superfície do eletrodo, que consiste em uma compressão do compósito, seguido de tratamento eletroquímico da superfície do eletrodo de trabalho, que se mostraram fundamentais para o desempenho adequado do sensor. Os resultados desses estudos inciais foram avaliados usando K3[Fe(CN)6], como sonda eletroquímica. Em seguida, o EIGPU foi avaliado quanto ao seu potencial para determinação de analitos de interesse farmacológico, usando como modelo o paracetamola (APAP) e suas misturasb com cafeína (CAF) em amostras de fármacos (LOD=0,81a, 0,84b(APAP), 1,6b(CAF) µmol L-1); ambiental: Zn2+, Pb2+, Cu2+ e Hg2+ simultaneamente em amostras de etanol combustível (LOD=300, 65, 30, 46 nmol L-1, respectivamente) e biológico: epinefrina (EP) em amostras artificiais de fluido cérebro-espinal sintético (LOD=42,8 e 768 nmol L-1, para DPV e SWV, respectivamente). Para isso, foram usadas Voltametria Cíclica (CV), Voltametria de Pulso Diferencial (DPV), Voltametria de Pulso Diferencial de Redissolução Anódica (DPASV) e Voltametria de Onda Quadrada (SWV). Na determinação dos analitos de interesse ambiental, os eletrodos impressos foram modificados com sílica SBA-15, antes e após organofuncionalização com a espécie benzotiazol-2-tiol. Os compósitos modificados foram preparados substituindo quantidades correspondentes de pó de grafite de modo a obter eletrodos com 5% (m/m) do modificador. Antes de realizar as análises, foram feitas as otimizações dos parâmetros envolvidos em cada técnica escolhida e obtidas as curvas analíticas. Em seguida, o EIGPU foi utilizado na determinação dos analitos nas respectivas matrizes. A quantidade dos analitos presentes nas amostras foi determinada pelo método de adição de padrão, em triplicata. Os resultados foram comparados com aqueles obtidos por Cromatografia Líquida de Alta Eficiência (HPLC) e Espectroscopia de Absorção Atômica (AAS), para as análises farmacêuticas e ambientais, respectivamente. / A method for the fabrication of a graphite polyurethane composite based screen printed electrodes (EIGPU) was proposed by developing a ink and a imprinting procedure after optimizing parameters such as ink composition 60% graphite and 40% polyurethane (m/m), nature and quantity of solvent, dimensions of the electrode set, number of ink layers, deepness of the adhesive mask and nature of the insulating that defines the active electrode area and the electrical contacts. Procedures for activating the electrode surface, by mechanically compressing the ink followed by an electrochemical treatment of the surface were also developed. The results of this phase were evaluated using K3[Fe(CN)6] as an electrochemical probe. Than the EIGPU was evaluated regarding its potentialities for the determination of analytes with pharmacological interest using paracetamola (APAP) and its mixturesb with caffeine (CAF) in pharmaceutical formulations (LOD=0,81a, 0,84b(APAP), 1,6b(CAF) µmol L-1), environmental relevance as metal ions Zn2+, Pb2+, Cu2+ e Hg2+ determined simultaneously in ethanol fuel samples (LOD=300, 65, 30, 46 nmol L-1, respectively) and biologically important as epinephrine (EP) contained in artificial cerebro-spinal fluid. (LOD=42,8 e 768 nmol L-1, for DPV e SWV, respectively).These applications were achieved by means of Cyclic Voltammetry (CV), Differential Pulse Voltammetry (DPV), Square Wave Voltammetry (SWV) and Differential Pulse Anodic Stripping Voltammetry (DPASV). In the determination of the metal ions in ethanol fuel, the electrodes were modified with SBA-15 silica organofunctionalized with benzothiazol-2-thiol. The composities were prepared by substituting corresponding amounts of graphite powder in order to have 5% (m/m) of the modifier in the final device. Before performing the analysis several parameters were optimized for each case for each technique before measuring the analytical curves. After, the EIGPU was used in the determination of the different analytes in the chosen matrices. The amount of analytes present in the samples was determined using addition method in triplicate. The results were compared with those obtained using high performance liquid chromatography (HPLC) and Atomic Absorption Spectrocopy (AAS), as comparision methods.
156

DESENVOLVIMENTO DE UM SIMPLES E NOVO SENSOR PARA FLUTAMIDA À BASE DE NANOTUBOS DE CARBONO OXIDADO E ÓXIDO DE GRAFENO: APLICAÇÃO EM AMOSTRAS DE URINA ARTIFICIAL E FORMULAÇÕES FARMACÊUTICAS / DEVELOPMENT OF A NEW AND SIMPLE SENSOR FOR FLUTAMIDE TO BASE OXIDIZED CARBON NANOTUBES AND GRAPHENE OXIDE: APPLICATION IN ARTIFICIAL URINE SAMPLES AND PHARMACEUTICAL FORMULATIONS

FARIAS, Julianna Santos 06 March 2017 (has links)
Submitted by Maria Aparecida (cidazen@gmail.com) on 2017-04-12T15:30:06Z No. of bitstreams: 1 Juliana Santos Farias.pdf: 1234303 bytes, checksum: 420e49b91acb05fb1346e95075411509 (MD5) / Made available in DSpace on 2017-04-12T15:30:06Z (GMT). No. of bitstreams: 1 Juliana Santos Farias.pdf: 1234303 bytes, checksum: 420e49b91acb05fb1346e95075411509 (MD5) Previous issue date: 2017-03-06 / CAPES, FAPEMA,CNPQ / This paper describes the development of a simple and new sensor electrochemical determination of flutamide in voltamétrica formulations pharmaceutical and artificial urine specimens using a carbon electrode vitreous (ECV) modified with oxidized carbon nanotubes and graphene oxide (NCO-OG), which was named ECV/NCO-OG. Electronic microscopy techniques scanning (SEM) and Raman Spectroscopy were used for the characterization of carbon based materials. The electrochemical response of the analyte front of the ECV/NCO-OG was investigated by cyclic voltammetry techniques (VC) and square wave voltammetry (VOQ). The sensor exhibited a high activity eletrocatalítica for the reduction of flutamide in 0.05 V vs. Ag/AgCl. The parameters experimental influence the response of the electrode was investigated and the optimum conditions were found for the electrode modified with NCO-OG, in Britton-Robinson buffer solution-BR on concentration of 0.1 mol L-1 (pH 5). The proposed sensor presented a wide range of linear response of concentration for the flutamide of 0.1 to 1000 µmol L-1 (or µ g L-1 27.6 to 0.27 g L-1) for n = 15 (R2 = 0.997), limit of detection (LOD), limit of quantification (LOQ), and sensitivity of 0.03 µmol L-1, 0.1 µmol L-1, and 0.30 µmol µA -1 L, respectively. The ECV/NCO-OG was successfully applied to the determination of flutamide in pharmaceutical formulations used in the treatment of prostate cancer and artificial urine samples. The results obtained with the proposed sensor were compared with the method described in the literature and showed a level of 95% confidence, demonstrating that there is no statistical difference between the method of reference and the method proposed. The addition and recovery studies show that the proposed method presents a satisfactory accuracy with average value of 101% recovery ( 1)%. for the fortified samples. / Este trabalho descreve o desenvolvimento de um simples e novo sensor eletroquímico para determinação voltamétrica de flutamida em formulações farmacêuticas e amostras de urina artificial empregando um eletrodo de carbono vítreo (ECV) modificado com nanotubos de carbono oxidado e óxido de grafeno (NCO-OG), o qual foi denominado ECV/NCO-OG. As técnicas microscopia eletrônica de varredura (MEV) e a Espectroscopia Raman foram utilizadas para a caracterização dos materiais à base de carbono. A resposta eletroquímica do analito frente ao ECV/NCO-OG foi investigada através das técnicas de voltametria cíclica (VC) e voltametria de onda quadrada (VOQ). O sensor exibiu uma alta atividade eletrocatalítica para a redução da flutamida em 0,05 V vs Ag/AgCl. Os parâmetros experimentais que influenciam a resposta do eletrodo foram investigados e as condições ótimas foram encontradas para o eletrodo modificado com NCO-OG, em solução tampão Britton-Robinson-BR na concentração de 0,1 mol L-1 (pH 5). O sensor proposto apresentou uma ampla faixa de resposta linear de concentração para a flutamida de 0,1 a 1000 µmol L-1 (ou 27,6 µg L-1 a 0,27 g L-1) para n=15 (R2=0,997), com limite de detecção (LOD), limite de quantificação (LOQ), e sensibilidade de 0,03 µmol L-1, 0,1 µmol L-1, e 0,30 µA µmol-1 L, respectivamente. O ECV/NCO-OG foi aplicado com sucesso para a determinação de flutamida em formulações farmacêuticas utilizadas no tratamento de câncer de próstata e amostras de urina artificial. Os resultados obtidos com o sensor proposto foram comparados com o método descrito na literatura e observou-se um nível de confiança de 95%, demonstrando que não há diferença estatística entre o método de referência e o método proposto. Os estudos de adição e recuperação mostram que o método proposto apresenta uma exatidão satisfatória com valor médio de recuperação de 101% ( 1) %. para as amostras fortificadas.
157

Singularidades associadas ao mecanismo de estabilização eletroestérico e seus efeitos sobre o comportamento reológico de suspensões concentradas. / Singularities related to the electrosteric stabilization mechanism and their effects over the rheological behaviour of concentrated suspensions.

Kleber Lanigra Guimarães 13 November 2008 (has links)
O presente projeto de trabalho buscou avaliar e estabelecer relações de causa e efeito que justificassem a ocorrência de singularidades no comportamento reológico de formulações complexas contendo elevada carga de sólidos em suspensão incorporada. O mecanismo de estabilização coloidal empregado para preparação das formulações e posterior análise foi o mecanismo de estabilização eletroestérico. O caso particular estudado correspondeu à dispersão de cargas inorgânicas (óxido de alumínio) em meio aquoso auxiliada pela incorporação de conteúdo orgânico com ação dispersante (poliacrilato de amônio) e ligante (emulsão acrílica) respectivamente. A implementação de técnicas analíticas complementares permitiu o estudo detalhado de uma singularidade associada ao comportamento reológico do sistema, exclusivamente evidenciada em função da elevada carga de sólidos, oferecendo, portanto, subsídios para elaboração de um modelo supramolecular fundamentado em possíveis alterações de configuração das cadeias poliméricas para justificativa do fenômeno. A contribuição referente ao pleno entendimento do fenômeno, considerando-se suas causas e efeitos, reside na possibilidade de se estabelecer diretrizes de formulação que propiciem a otimização das quantidades de aditivos incorporados e o respectivo controle do estado de dispersão e estabilidade do sistema. Considerou-se, para efeitos práticos de engenharia de formulação, que o mínimo secundário de viscosidade corresponda ao ponto ótimo de estabilidade do sistema mesmo que a condição de máxima dispersão já tenha sido alcançada para uma concentração de dispersante equivalente ao mínimo primário de viscosidade. A contribuição do efeito estérico associada à reduzida distância de separação entre as partículas (IPS) mostrou-se de vital importância para assegurar a viabilidade de uma dada formulação. A proposta aqui apresentada fundamentou-se no mecanismo de depleção como principal força motriz para desencadear possíveis mudanças de conformação espacial das cadeias poliméricas implicando, portanto, em alterações do raio hidrodinâmico, da fração volumétrica efetiva ocupada e da intensidade de interação (repulsão) entre as partículas. O efeito da dinâmica configuracional sofrida pelo sistema refletiu-se diretamente no comportamento reológico do mesmo. O caráter de inovação do presente trabalho reside na utilização não convencional da técnica de espectroscopia eletroacústica, empregada para avaliação de mudanças do raio hidrodinâmico de partículas em suspensão (sistemas concentrados), integrada com a técnica de turbidimetria dinâmica de varredura para avaliação de desempenho (cinética de sedimentação) de formulações complexas (suspensões). / The present research project pretended to evaluate and establish cause and effect relationships able to justify the singularities evidenced when exploring the rheological behaviour of complex formulations containing elevated solids loading. The stabilization mechanism used for the preparation of the dispersed systems and subsequent analyses corresponded to the electrosteric mechanism. The particular case studied herein corresponded to the dispersion of inorganic colloidal particles (aluminun oxide) in aqueous media assisted by the incorporation of organic components acting respectively as dispersant (ammonium polyacrylate) and binder agent (acrylic emulsion). The implementation of complementary analytical techniques enabled the detailed study of a singularity related to the rheological behaviour of the system that could only be evidenced for high solids loading condition. The results obtained provided the fundamental concepts necessary to propose a supramolecular model based on possible conformational changes associated with the adsorbed polymeric chains and sufficient to justify the phenomenon. Considering the practical aspects related to formulation engineering, it was determined that the secondary minimum viscosity corresponds to the optimum stablity condition although the maximum dispersion condition was achieved for dispersant concentrations equal to the primary minimum viscosity. The contribution of the steric effect associated with the reduced interparticle separation distance (IPS) showed itself to be of vital importance to ensure the viability of a stable formulation. The proposal here presented suggests that the depletion mechanism corresponds to the major cause that imparts possible configurational changes related to the adsorbed polymer chains. As a result of, significant alterations of the hydrodynamic radius, effective volume fraction occupied by and interaction intensity (repulsion) between the particles are expected. The effect of the configurational dynamics experienced by the system reflected directly on the associated rheological behaviour.The innovation character of the present work relies on the employment of the electrosacoustic spectroscopy technique to evaluate possible changes of the hydrodynamic radius of the suspended particles (concentrated systems) integrated with the dynamic turbidimetry technique to evaluate the performance (sedimentation kinetics) of the complex formulations.
158

Determinação simultânea de propifenazona, paracetamol e cafeína utilizando eletrodo de diamante dopado com boro

Silva, Weberson Pereira da 16 February 2017 (has links)
Fundação de Amparo a Pesquisa do Estado de Minas Gerais / No presente trabalho investigou-se o desenvolvimento de novos procedimentos analíticos para a determinação simultânea de paracetamol (PAR), propifenazona (PRO) e cafeína (CAF) em formulações farmacêuticas. Três métodos foram desenvolvidos usando as técnicas de voltametria de onda quadrada (SWV) e amperometria de múltiplos pulsos (MPA) e diamante dopado com boro (BDD) como eletrodo de trabalho. Empregando a SWV, duas estratégias de análise foram desenvolvidas: (I) uso de uma célula eletroquímica convencional (modo estacionário) e o método de adição de padrão; (II) uso de análise por injeção em batelada com detecção por voltametria de onda quadrada (BIA-SWV) e o método de calibração externa. Os métodos propostos foram desenvolvidos usando como eletrólito de suporte H2SO4 0,1 mol L-1 e os parâmetros otimizados da SWV foram: potencial de condicionamento: -1,5 V durante 20 s; frequência: 60 s-1; amplitude: 50 mV e incremento de potencial: 4 mV. No método proposto empregando BIA-SWV, o volume e a velocidade de injeção otimizados foram de 100 μL e 28 μL s-1, respectivamente. Um terceiro método proposto para determinação simultânea de PAR, PRO e CAF, o procedimento de análise por injeção em batelada com detecção por amperometria de múltiplos pulsos (BIA-MPA) foi empregado. Três pulsos de potenciais foram selecionados para realização da análise: +0,90 V /50 ms: apenas o PAR foi oxidado sem a interferência dos outros dois compostos; +1,20 V /50 ms: oxidação do PAR e da PRO livre da interferência da CAF; +1,60 V /50 ms: oxidação dos três compostos (PAR, PRO e CAF). A seletividade na detecção da PRO e CAF foi obtida mediante subtração de correntes entre os amperogramas adquiridos nos potenciais selecionados e o uso de fatores de correção (FCs). Todos os procedimentos de análise desenvolvidos mostraram-se estáveis (DPR < 4,1%) e lineares (r > 0,997). O método empregando uma célula eletroquímica convencional apresentou frequência analítica de 20 análises h-1 e limites de detecção de 0,005, 0,009 e 0,006 mg L-1 para PAR, PRO e CAF, respectivamente. Os métodos BIA-SWV e BIA-MPA apresentaram frequência analítica muito superior: 80 e 75 análises h-1, respectivamente. Os limites de detecção foram de 0,3, 0,2 e 0,3 mg L-1 (BIA-SWV) e 0,2, 0,3 e 0,1 mg L-1 (BIA-MPA) para PAR, PRO e CAF, respectivamente. / In this work we investigated the development of new analytical procedures for simultaneous determination of paracetamol (PAR), propyphenazone (PRO) and caffeine (CAF) in pharmaceutical formulations. Three methods was developed using of Square wave voltammetry (SWV), multiple pulse amperometry (MPA) and boron doped diamond (BDD) with work electrode. Employing SWV, two analysis strategies were developed (I) Use of a conventional electrochemical cell (stationary mode) and the standard addition method; (II) use of batch injection analysis with detection by square wave voltammetry (BIA-SWV) and external calibration method. The proposed methods were developed using H2SO4 0.1 mol L-1 as supporting electrolyte and optimized parameters of the SWV: Conditioning potential: -1.5 V during 20 s; frequency: 60 s-1; amplitude: 50 mV and step potential: 4 mV. In the proposed method using BIA-SWV, volume and speed of optimized injection were 100 μL e 28 μL s-1, respectively. On the third method proposed for simultaneous determination of the PAR, PRO and CAF, the batch injection analysis procedure with multiple pulse amperometry detection (BIA-MPA) was employed. Three potentials pulses were selected for the analysis: +0.90 V/50 ms: only PAR was oxidized without the interference of the other two compounds; +1.20 V/50 ms: oxidation PAR and PRO without the interference of the CAF; +1.60 V/50 ms: oxidation of the three compounds (PAR, PRO and CAF). The selectivity in the detection of PRO and CAF was obtained by subtracting currents between the amperograms acquired in the selected potentials and the use of correction factors (CFs). All developed analysis procedures remained stable (RSD < 4.1%) and linear (r > 0.997). The method using a conventional electrochemical cell showed an analytical frequency of 20 analysis h-1 and limits of detection of 0.005, 0.009, and 0.006 mg L-1 for PAR, PRO, and CAF, respectively. The BIA-SWV and BIA-MPA methods presented higher analytical frequency: 80 and 75 analysis h-1, respectively. The limits of detection were 0.3, 0.2, and 0.3 mg L-1 (BIA-SWV) and 0.2, 0.3, and 0.1 mg L-1 (BIA-MPA) for PAR, PRO and CAF, respectively. / Dissertação (Mestrado)
159

Avaliação de efetividade, custos e eventos adversos de bombas de infusão de medicamentos : um ensaio clínico randomizado

Torelly, Ethel Maris Schroder January 2009 (has links)
Objetivo: Este estudo objetivou avaliar a precisão de infusões de medicamentos em dois modelos de Bomba de Infusão (BI), de equipo específico do fabricante e de equipo universal, a concordância entre estes dois modelos e sua relação de custo e efetividade. Método: Foi realizado um ensaio clínico randomizado em pacientes internados em um hospital geral universitário de 740 leitos. As unidades de internação foram randomizadas através de sorteio simples para cada modelo de equipamento e os pacientes foram incluídos de acordo com indicação de uso de BI, conforme protocolo institucional. Os tipos de erros e reações adversas foram classificados por meio de algoritmos. Foi calculado o custo de cada sistema de bomba de infusão, pela vida útil da tecnologia. Resultados: Em 55 pacientes foram acompanhadas 310 infusões, 117 no grupo da bomba de infusão de equipo universal e 193 na bomba de infusão de equipo especifico. Houve semelhança (p=0,40) entre o tempo programado e o observado nas infusões por meio da bomba de equipo específico (-2,1 ± 19 min) e universal (0,08 ± 23 min). Percentualmente, também não foi observada diferença (p=0,70) entre a infusão por bomba de equipo específico (-0,15±3,8%) e universal (0,1±6,3%). Foram observados 14 (4,5%) erros de medicação, semelhantes (p=0,58) entre os tipos de BI. Os custos cumulativos entre os dois sistemas de bombas se equivaleram em 30 meses, sendo que após 11 anos, foram significativamente maiores para bomba de equipo específico em 184,29%. Conclusão: Ambos modelos de BI avaliadas mostraram-se igualmente seguras para administração EV de fármacos, sendo o modelo de equipo universal mais vantajoso economicamente ao longo da vida útil dos equipamentos. / Objective: This study aimed to evaluate the accuracy of drug infusion in two models of infusion pumps (IP), one with a specific IV set and other with universal IV set, the correlation between these two models and their relation of cost and effectiveness. Method: A randomized clinical trial was conducted in hospitalized patients in a university general hospital of 740 beds. The ward units were randomly chosen for each type of equipment, and patients were included according to indication for use of IP, based on institutional protocol. The types of errors and adverse reactions were classified by means of algorithms. The costs of each system for IP, was calculated considering the useful life of the technology. Results: 310 infusions were monitored: 117 in the universal infusion pump group and 193 in the specific equipment group, in 55 patients. The average difference between the scheduled time and the actual one in the infusions was -2.1 ± 19 min. and 0.08 ± 23 min. (p = 0.40) for the universal equipment and specific equipment, respectively, which means an average error of -0.15% ± 3.8% for the universal equipment and 0.10% ± 6.3% for the specific equipment, with no difference between the two types of pump. Fourteen (4.5%) medication errors were observed during the administration of medication, similar between the two types of IP. The cumulative costs between the two pump systems were equivalent in 30 months, and after 11 years the costs were meaningfully higher for the specific equipment pumps in 184,29 %. Conclusion: The infusion pumps do not show meaningful difference in accuracy between scheduled time and the actual one qualifying them as safe for the drugs observed. Cumulative costs were significantly distinct between both pieces of equipment.
160

Judicialização da Saúde: Características das ações judiciais recebidas na Secretaria de Ciência, Tecnologia e Insumos Estratégicos do Ministério da Saúde no ano de 2007 / Judicialization of Health: Characteristics of lawsuits received at the Secretary of Science, Technology and Strategic Inputs (SCTIE) of the Ministry of Health in the year 2007

Veloso, Sandra Ceciliano de Souza [UNIFESP] 26 January 2011 (has links) (PDF)
Made available in DSpace on 2015-07-22T20:50:24Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-01-26. Added 1 bitstream(s) on 2015-08-11T03:26:13Z : No. of bitstreams: 1 Publico-12866.pdf: 452879 bytes, checksum: cbd7a421771ee8ed837a1515f62fa5ea (MD5) / Introdução: Atualmente, as duas maiores demandas por recursos financeiros para a assistência farmacêutica são o Programa de Medicamentos Excepcionais e o atendimento às demandas judiciais para o fornecimento de medicamentos. As demandas judiciais, além de desorganizar o serviço, comprometem a equidade e se contrapõe às definições coletivas. Portanto, se faz prioritário um estudo que descreva as características dessas ações para subsidiar as políticas públicas de saúde. Objetivo: Descrever as características das ações judiciais recebidas na Secretaria de Ciência, Tecnologia e Insumos Estratégicos (SCTIE) do Ministério da Saúde no ano de 2007. Material e Método: Análise descritiva contemplando o total de ações recebidas no ano de 2007. Foram avaliadas a distribuição das ações por estado, as características das solicitações, classificação dos medicamentos quanto a regulamentação e disponibilidade e considerações sobre evidências científicas. Resultados: No ano de 2007 foram recebidos na Secretaria de Ciência, Tecnologia e Insumos Estratégicos (SCTIE) 832 processos de ações judiciais. Essas ações foram provenientes de 20 Estados da Federação, sendo o maior número de ações, 207 (24,88%), provenientes do estado de Santa Catarina, seguido do estado do Rio Grande do Sul com 127 (15,14%). Incluindo as ações provenientes do estado do Paraná, a Região Sul do país totalizou 50,72% das ações recebidas em 2007. Do total de 832 ações 444 (53,37%) foram de solicitações de medicamentos ou produtos específicos. Destas apenas duas foram de produtos para saúde, as demais foram de medicamentos. Os medicamentos mais solicitados foram adalimumabe e etanercepte que juntos correspondem a 16,89% do total de solicitações e foram geradas por estados da região sul em sua maioria. Os 11 medicamentos mais solicitados representam 47,07% do total. As indicações dos medicamentos de uma maneira geral foram conforme a regulamentação e são indicados para doenças crônicas, sendo que dois ainda não possuíam registro na ANVISA. Dos onze medicamentos mais solicitados nenhum constava da Relação Nacional de Medicamentos Essenciais e 3 (três), adalimumabe, etanercepte e infliximabe já faziam parte da Lista do Componente de Medicamentos de Dispensação Excepcional. Quanto à evidência científica foi observado que para a maioria dos medicamentos seriam necessários estudos complementares para evidências de efetividade, segurança e custo-benefício. Conclusão: A análise das ações judiciais é necessária para a avaliação das políticas e gestão dos serviços de saúde e também para auxiliar na identificação de medicamentos para avaliação tecnológica. O conhecimento dos fatores que levam os medicamentos às ações judiciais, somada a aproximação do poder judiciário com os gestores e profissionais de saúde podem atingir o objetivo comum de uma saúde pública de qualidade, universal e integral, baseadas na equidade. / Introduction: Currently, the two largest financial resources demands for pharmaceutical assistance are exceptional medicines programme and legal demands service for the supply of medicines. The legal demands, and disrupt the service, commitment to fairness and collective contradict definitions. Therefore, it’s a priority a study that describes the characteristics of these actions to subsidize public health policies. Objective: To describe the characteristics of lawsuits received at the Secretary of Science, Technology and Strategic Inputs (SCTIE) of the Ministry of Health in the year 2007. Material and methods: A descriptive analysis that covers the total shares received in the year 2007. Were evaluated the distribution by State, the characteristics of requests, classification of medicines as the availability and regulatory and scientific evidence considerations. Results: In 2007 were received on the SCTIE 832 litigation processes. These actions were from 20 States of the Federation, being the largest number of actions, 207 (24,88%), from the State of Santa Catarina, followed by the State of Rio Grande do Sul with 127 (15,14%). Including the actions from the State of Paraná, the South region of the country totaled stock received 50,72% in 2007. Of the total of 832 actions 444 (53,37%) were requests for specific products or medicines. These are only two medical devices, the others are medicines. Most requested medicines were adalimumab and etanercept which together correspond to 16,89% of total requests and were generated by southern states in its majority. The 11 most requested medicines represent 47.07% of the total. In general the medicines indications were as regulation and are indicated for chronic diseases, two were not registered at ANVISA yet. The eleven medicines most requested were not found in the national essential medicines (RENAME) and 3 (three), adalimumab, etanercept and infliximab were already part of the exceptional dispensing medicines (CDME). Regarding the scientific evidence was found that for most medicines would need further studies for evidence of effectiveness, safety and cost-effectiveness. Conclusion: The analysis of lawsuits is needed for the evaluation of policies and management of health services and also to assist in identifying medicinal products for health technology assessment. Knowledge of the factors that lead to lawsuits medicines added approximation of judiciary with managers and health professionals can achieve the common goal of a quality public health, universal and comprehensive based on fairness. / TEDE / BV UNIFESP: Teses e dissertações

Page generated in 0.0583 seconds