• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 832
  • 26
  • 9
  • 7
  • 7
  • 6
  • 5
  • 4
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 886
  • 578
  • 151
  • 110
  • 109
  • 100
  • 88
  • 83
  • 79
  • 77
  • 67
  • 65
  • 63
  • 56
  • 54
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
131

Validação de métodos para as técnicas de WDXRF e OES -spark, na análise de aços. Cálculo de incerteza de medição para amostras de processo, aço classe API / VALIDATION OF METHODS FOR WDXRF AND OES-SPARK TECHNIQUES IN STEEL ANALYSIS. DETERMINATION OF THE UNCERTAINTY OF MEASUREMENTS FOR API STEEL PLANT SAMPLE

Silva, Carlos Eduardo da 18 February 2009 (has links)
Em conseqüência do aumento da demanda de gás e petróleo no mercado nacional e internacional, as especificações e certificações dos resultados de analises químicas de tubos para gasodutos e oleodutos têm se tornados cada vez mais exigentes. Um contínuo desenvolvimento tem sido realizado para a melhoria de aços microligados da classe API (American Petroleum Institute). As propriedades do aço dependem do controle da composição química e parâmetros de processo durante sua fabricação. Neste trabalho, foi realizada comparação das incertezas de medição entre as técnicas de espectrometria de fluorescência de raios X por comprimento de onda (WDXRF) e de emissão óptica com fonte de arco voltaico (OES-spark) nas análises de acompanhamento de processo na produção de aços classe API. Usualmente, este tipo de análise requer menos de 40 segundos para completa caracterização química para ajuste nos parâmetros de processo de produção. As principais fontes de influência nas análises químicas foram avaliadas por planejamento de experimentos. Os elementos constituintes e traço como Al, Si, P, S, Ti, V, Cr, Mn, Co, Ni, Cu, As, Nb, Mo e Sn foram determinados utilizando as metodologias normalizadas pela ASTM E-322, E-415, E-1009 e E-1085. Os materiais de referência certificados 185A e 187A da CMI (Czech Metrology Institute) foram utilizados para avaliação dos métodos. As incertezas das medições de resultados e a validação com relação a repetitividade e reprodutibilidade das medições foram obtidas conforme os testes estatísticos, recomendados pela norma ISO/IEC 17025. A incerteza de medição para cada elemento é discutida para ambas as técnicas. / The increase of gas and petroleum demanding in the national and international markets, the specification and certification of the chemical analysis results of gas and oil pipe-line have became more and more challenging. A continuous development has been outlined to improve API grade alloy steels (American Petroleum Institute). The steel properties depend on the chemical composition control and process parameters during its manufacturing. In this work, a comparison of the measurement uncertainty between X-ray fluorescence (WD system) and Optical Emission (OES-spark) spectrometries, for API grade steel plant samples analysis, was outlined. Usually, this kind of analyze requires less than 40 seconds for full chemical characterization for adjustment in the process parameters production. The main influence source in the chemical analysis was evaluated for design of experiments. The constituents and trace elements such as Al, Si, P, S, Ti, V, Cr, Mn, Co, Ni, Cu, As, Nb, Mo and Sn were determined using the ASTM E-322, E-415, E-1009 and E-1085 standard methodologies. The 185A and 187A certified reference materials from CMI (Czech Metrology Institute) were used for evaluation of the methods. The uncertainty of the measurement, precision, accuracy, repeatability and reproducibility of the measurements were obtained applying statistic tests, recommended by ISO/IEC 17025. The uncertainty of measurement for each element is discussed for both techniques.
132

Controle de qualidade na analise de silicatos por espectrometria de fluorescencia de raios X

Vendemiatto, Maria Aparecida 08 February 2001 (has links)
Orientador : Jacinta Enzweiler / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Geociencias / Made available in DSpace on 2018-07-28T19:42:19Z (GMT). No. of bitstreams: 1 Vendemiatto_MariaAparecida_M.pdf: 4921255 bytes, checksum: 8fa65f7fb2585244f582f44a3c2a5dba (MD5) Previous issue date: 2001 / Resumo: Esta dissertação propõe um método simples de controle da qualidade de resultados, na análise de silicatos por espectrometria de fluorescência de raios X, baseado na expressão de Horwitz modificada (Hc = 0,01c0,8495 qual prevê como a precisão analítica Hc varia com a concentração do analitos. A expressão foi utilizada para calcular Hc de cada valor recomendado VR dos materiais de referência utilizados para avaliar a exatidão. O intervalo VR±Hc foi tomado como limite de aceitação dos resultados analíticos. Programas de determinação de elementos maiores (Si02, TiO2, A1203, Fe203, MnO, MgO, CaO, Na20, K2O, P2Os) em discos de vidro e de traços (Ba, Ce, Cr, Cs, Cu, Ga, La, Nb, Nd, Ni, Pb, Rb, Se, Sn, Sr, Th, U, V, Y, Zn e Zr) em pastilhas prensadas foram elaborados e os resultados analíticos de nove materiais de referência foram avaliados. A adoção do intervalo VR±Hc como critério de aceitação dos resultados foi útil para identificar deficiências e erros sistemáticos na calibração do espectrômetro e corrigi-Ios. Observou-se que os resultados dos elementos maiores facilmente atendem ao intervalo VR±Hc, enquanto para os elementos-traços, os resultados nem sempre caem naquele intervalo, especialmente quando a concentração é próxima do limite de detecção. Este efeito foi atribuído aos tempos de leitura (contagens) adotados e, também, às incertezas dos valores recomendados dos materiais de referência. A precisão foi medida com a análise de dez pastilhas prensadas e dez discos de vidro de uma amostra de referência interna (BAC). Os coeficientes de variação da maior parte dos resultados encontram-se entre 0,2 e 2,6%. Adicionalmente, o método de duplicação das amostras foi usado para avaliar a contribuição de cada etapa do processo analítico à precisão total. As etapas avaliadas foram a cominuição da amostra (homogeneização do material britado, quarteamento e moagem), a preparação dos discos de vidro e pastilhas prensadas e a medida instrumental. Para a maioria dos analitos (maiores e muitos traços), a cominuição é a etapa que mais contribui à incerteza analítica total, seguida da preparação dos discos de vidro ou pastilhas prensadas. Na faixa de menor concentração, isto é, para alguns elementos-traços, a precisão instrumental é a etapa cuja contribuição é dominante em relação às demais / Abstract: This dissertation proposes a simple method for quality control of results in silicate analysis by X-ray fluorescence spectrometry, based on the modified Horwitz expression, (Hc = 0,01c0,8495 which allows to foresee the analytical precision Hc according to the analyte concentration c. The expression was used to calculate Hc of each recommended value RV of the reference materials used to evaluate the accuracy. The interval RV±Hc was taken as limits to accept the analytical results. Analytical programs for determination of major elements (SiO2, Ti_, A12O3, F_O3, MnO, MgO, CaO, Na20, K2O, P20S) in glass disks and of traces (8a, Ce, Cr, Cs, Cu, Ga, La, Nb, Nd, Ni, Pb, Rb, Sc, Sn, Sr, Th, U, V, Y, Zn e Zr) in pressed pellets were prepared and analytical results of nine reference materials were evaluated. The interval RV±Hc as criterion for acceptance of results was useful to identify deficiencies and systematic errors of the spectrometer calibration, and to correct them. It was observed that results of major elements easily fall within the interval RV±Hc, while results of trace elements sometimes exceed it, specially when concentration is close to the detection limit. This effect was attributed to the counting times adopted for analysis and, also, to the uncertainties associated to the recommended values of the reference materials. The precision was measured by analysis of ten pressed pellets and ten glass disks of an in-house reference sample (BAC). The coefficients of variation of most results were between 0.2 and 2.6%. Additionally, the method of sample duplication was used to evaluate the contribution of each stage of the analytical process to the whole precision. Sample comminution (homogenisation of crushed material, quartering and grinding), is the step that contributes mostly to the whole analytical uncertainty, followed by glass disks and pressed pellets preparation. At the low level concentration, i.e., for some trace elements, the instrumental measurement represents the dominant contribution, in comparison to the others / Mestrado / Metalogenese / Mestre em Geociências
133

Uso de imagens de fluorescência para monitoramento da evolução do cancro cítrico / Use of fluorescence imaging for monitoring the evolution of citrus canker

Caio Bruno Wetterich 29 February 2012 (has links)
A doença cancro cítrico é considerada uma das mais importantes doenças da citricultura devido ao seu poder de proliferação nas fazendas, e aos danos causados às plantas e frutos. Os prejuízos causados pela presença da doença são consideravelmente preocupantes, pois as principais medidas de controle pelos órgãos responsáveis envolvem a erradicação de plantas infectadas e demais plantas vizinhas, inviabilizando economicamente grandes áreas produtivas. A legislação brasileira exige um extenso protocolo de atividades que necessita ser realizado antes da confirmação do diagnóstico. Atrasos na confirmação do diagnóstico favorecem a proliferação da doença. Assim, qualquer esforço em acelerar esta detecção deve com certeza ter um grande impacto nesta área. Esta é a motivação de nosso trabalho, onde aplicamos a técnica de espectroscopia por imagens de fluorescência em folhas de culturas cítricas com a intenção de avaliar a capacidade de diagnóstico desta técnica em plantas assintomáticas contaminadas no laboratório com cancro cítrico. O objetivo é determinar o instante de tempo mínimo necessário entre a infecção e o diagnóstico preciso da doença. Este estudo foi aplicado para experimentos envolvendo amostras destrutivas e não-destrutivas. Os resultados mostram a possibilidade de aplicar tal técnica na detecção de cancro cítrico. / The citrus canker disease is considered one of the most important citrus diseases due to its ability to spread on farms, and to damage plants and fruits. The damage, caused by the citrus canker, can be devastating, because the main control actions involve the eradication of infected plants and other plants nearby, causing large economic losses. Brazilian law requires an extensive testing protocol to confirm the diagnosis. Delays in diagnosis tests allows the spread of the disease. Therefore, any effort to accelerate this procedure will have a major impact in this area. This is the motivation of our work, where we apply the fluorescence imaging spectroscopy technique on citrus leaves with the goal to evaluate the diagnostic capability of this technique in asymptomatic plants infected with citrus canker in the laboratory. The goal is to determine the minimum time delay between infection and accurate diagnosis of the disease. This study was applied to experiments involving non-destructive and destructive samples. The results show the possibility of applying this technique in the detection of citrus canker.
134

Analise multielementar quantitativa de solos e sedimentos por espectrometria de fluorescencia de raios X

Zambello, Fabio Roberto 06 August 2001 (has links)
Orientador : Jacinta Enzweiler / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Geociencias / Made available in DSpace on 2018-08-01T12:28:02Z (GMT). No. of bitstreams: 1 Zambello_FabioRoberto_M.pdf: 1951712 bytes, checksum: da9a4d79c2401be47cc928713c2fa44b (MD5) Previous issue date: 2001 / Resumo: Esta dissertação avalia a utilização da espectrometria de fluorescência de raios X por comprimento de onda (FRX), como ferramenta analítica de solos e sedimentos, para aplicações em geologia econômica e geoquímica ambiental. A capacidade multielementar e rapidez analítica da FRX a tomam atrativa em projetos de mapeamentos geoquímicos de composição elementar, de prospeção geoquímica de depósitos minerais e na avaliação da contaminação ambiental por metais pesados. Uma dificuldade encontrada na análise de solos e sedimentos por FRX é calibrar o instrumento para uma ampla faixa de concentração, empregando materiais de referência. Estes raramente são caracterizados para todos os elementos de interesse, podendo também apresentar heterogeneidades em algum grau, principalmente quando as amostras são simplesmente prensadas. Os progressos instrumentais dos últimos anos e o amplo interesse na análise rápida destas matrizes justificam o desenvolvimento e a avaliação de programas analíticos para esta aplicação. Um programa analítico quantitativo de detenninação de elementos maiores (Si, AI, Fe, Mg, Ca, K, Na, Mn, Ti e P) e traços (As, Ba, Cd, Co, Cr, Cu, Ga, Mo, Nb, Ni, Pb, Rb, S, Sb, Sn, Sr, Th, U, V, Y, Zn, e Zr) em pastilhas prensadas de solos e sedimentos foi preparado e as figuras de mérito associadas (precisão, exatidão e limites de detecção) foram avaliadas. Nas duas etapas (calibração e avaliação) foram utilizados mais de sessenta materiais de referência de solos e de sedimentos de fornecedores internacionais e um espectrômetro de fluorescência de raios X seqüencial. Os limites de detecção dos elementos-traço (1-5 /J99-1) são inferiores à concentração média na crosta para a maior parte deles, indicando que o programa analítico é adequado à finalidade a que se propõe. Os limites de detecção de Cd e Sb, de 1,6 e 1,9 J.19 g-1, respectivamente, são mais altos que a concentração média destes elementos em solos e sedimentos, mas pennitiriam detectá-Ios em concentrações anormalmente altas. As amostras de referência empregadas na avaliação da exatidão dos resultados não faziam parte do grupo utilizado na calibração do instrumento. Os resultados foram avaliados com três métodos. Os resultados obtidos para elementos-traço situam-se dentro do intervalo de confiança dos valores certificados ou muito próximos dos valores recomendados. Devido aos efeitos mineralógicos, a calibração dos elementos maiores foi mais compfexa, mas os resultados, em geral foram concordantes os valores recomendados. Eventuais discrepãncias serviram para aprimorar as curvas de calibração, e contribuíram para o melhor conhecimento dos materiais de referência empregados e nos critérios para a escolha das amostras de calibração / Abstract: This dissertation evaluates wavelength-dispersive X-ray fluorescence spedrometry (XRF) as an analytical tool of soils and sediments, for economic geology and environmental geochemistry applications. The multi-element capacity and the analytical speed of XRF are of interest to elemental geochemical mapping projects, in mineral deposits prospects and in the evaluation of the environmental contamination by heavy metais. A difficulty found in the analysis of soils and sediments by XRF is instrument calibration, for a wide range of elemental concentration, using reference samples. Those are rarely characterised for ali the elements of interest, may present inhomogeneities in some degree, mainly when the samples are simply pressed as pellets. The instrumental progress of the last years and the wide interest in the fast analysis of such matrices justify the development and the evaluation of analytical programs for this application. A quantitative analytical program for determination of major (Si, AI, Fe, Mg, Ca, K, Na, Mn, Ti and P) and trace elements (As, Ba, Cd, Co, Cr, Cu, Ga, Mo, Nb, Ni, Pb, Rb, S, Sb, Sn, Sr, Th, U, V, Y, 20, and Zr) in pressed pellets of soils and sediments was prepared and the associated figures of merit (precision, accuracy and detection limits) were evaluated. For the two stages (calibration and evaluation) more than sixty reference materiais of soils and sediments from intemational suppliers a sequential X-rays fluorescence spectrometer were used. The detection limits for trace elements (1-5 J.19g-1) indicate that the analytical program is fit-for-purpose, i.e., the considered elements can be analysed in most cases in such matrices. Exceptions are Cd and Sb, whose detection limits (1,6 and 1,9 J1g g-1, respectively) are too high, considering their average concentrations in soils and sediments, but would still be useful to detect anomalous concentrations. The reference samples used in the evaluation of the accuracy were others than those used for instrument calibration. Three methods were used to evaluate the results. The results of trace elements fali within the confidence interval of the certifted values or are very close of the recommended values. Due to the mineralogical effects, the calibration of the major elements was more complex, but the results, in general were in goOO agreement with recommended values. Eventual discrepancies were useful to improve calibrations and contributed to a better knowledge of the used reference samples and as criteria to choose the calibration samples / Mestrado / Metalogenese / Mestre em Geociências
135

Uso de imagens de fluorescência para monitoramento da evolução do cancro cítrico / Use of fluorescence imaging for monitoring the evolution of citrus canker

Wetterich, Caio Bruno 29 February 2012 (has links)
A doença cancro cítrico é considerada uma das mais importantes doenças da citricultura devido ao seu poder de proliferação nas fazendas, e aos danos causados às plantas e frutos. Os prejuízos causados pela presença da doença são consideravelmente preocupantes, pois as principais medidas de controle pelos órgãos responsáveis envolvem a erradicação de plantas infectadas e demais plantas vizinhas, inviabilizando economicamente grandes áreas produtivas. A legislação brasileira exige um extenso protocolo de atividades que necessita ser realizado antes da confirmação do diagnóstico. Atrasos na confirmação do diagnóstico favorecem a proliferação da doença. Assim, qualquer esforço em acelerar esta detecção deve com certeza ter um grande impacto nesta área. Esta é a motivação de nosso trabalho, onde aplicamos a técnica de espectroscopia por imagens de fluorescência em folhas de culturas cítricas com a intenção de avaliar a capacidade de diagnóstico desta técnica em plantas assintomáticas contaminadas no laboratório com cancro cítrico. O objetivo é determinar o instante de tempo mínimo necessário entre a infecção e o diagnóstico preciso da doença. Este estudo foi aplicado para experimentos envolvendo amostras destrutivas e não-destrutivas. Os resultados mostram a possibilidade de aplicar tal técnica na detecção de cancro cítrico. / The citrus canker disease is considered one of the most important citrus diseases due to its ability to spread on farms, and to damage plants and fruits. The damage, caused by the citrus canker, can be devastating, because the main control actions involve the eradication of infected plants and other plants nearby, causing large economic losses. Brazilian law requires an extensive testing protocol to confirm the diagnosis. Delays in diagnosis tests allows the spread of the disease. Therefore, any effort to accelerate this procedure will have a major impact in this area. This is the motivation of our work, where we apply the fluorescence imaging spectroscopy technique on citrus leaves with the goal to evaluate the diagnostic capability of this technique in asymptomatic plants infected with citrus canker in the laboratory. The goal is to determine the minimum time delay between infection and accurate diagnosis of the disease. This study was applied to experiments involving non-destructive and destructive samples. The results show the possibility of applying this technique in the detection of citrus canker.
136

Avaliação do efeito fotodinâmico a partir da associação dos precursores da PPIX (ALA e MAL) em epitélio suíno / Photodynamic effect evaluation from the association of the precursors of PPIX (ALA and MAL) in swine epithelium

Fujita, Alessandra Keiko Lima 23 May 2016 (has links)
A terapia fotodinâmica (TFD) utilizando ácido 5-aminolevulinico (ALA) e derivados em aplicação tópica e, como precursor da protoporfirina IX (PPIX) apresenta alguns limitantes relativos a baixa permeação das substâncias na pele. Comportamento este que afeta a produção e homogeneidade da distribuição da PPIX na superfície e camadas mais profundas da pele. Para resolver essa limitação muitos autores propõem alternativas modificando a molécula do ALA e derivados, bem como modificando as propriedades químicas da fase externa da emulsão (mais hidrofílica ou hidrofóbica) ou então o sistema de entrega para a emulsão. O objetivo desse estudo é avaliar qual a proporção de ALA e metil-5-aminolevulinato (MAL) que quando misturados levam ao aumento da quantidade e uniformidade da formação da PPIX na superfície e em profundidade na pele. Para esse estudo foi realizada análises de fluorescência e histologia. O estudo foi conduzido in vivo e ex vivo usando biópsias de pele de porco cultivadas in vitro. A produção de PPIX foi monitorada utilizando espectroscopia de fluorescência, imagem de fluorescência de campo amplo e microscopia confocal de fluorescência. E para a aplicação da TFD os parâmetros usados foram de 125 mW/cm2 de intensidade e 150 J/cm2 de dose. A análise do dano causado pela irradiação foi realizada por meio de histologia da pele após 24 e 48 horas da aplicação da TFD. O ALA e MAL na concentração de 20% foram misturados nas seguintes proporções: ALA ou M, M2 (80% ALA - 20% MAL), M3 (60% ALA 40% MAL), M4 (50% ALA MAL), M5 (40% ALA 60% MAL), M6 (20% ALA 80% MAL) e MAL como M7. As diferentes proporções foram incorporadas em emulsões óleo em água (O/A) e água em óleo (A/O). De acordo com os resultados, as misturas M3, M4 e M5 mostraram maior produção de PPIX na superfície da pele segundo as medidas de fluorescência em 3h de incubação e, no estudo da cinética mostraram produzir PPIX em menor tempo. No estudo de permeação do creme in vitro em pele ex vivo, por microscopia confocal de fluorescência, observou-se que as misturas M3, M4 e M5 produziram mais PPIX nas camadas da pele do que ALA e MAL. As análises histológicas das misturas apresentaram maior dano fotodinâmico na superfície e profundidade das camadas da pele após a TFD, independente da emulsão. A análise em até 48h observou-se predominantemente a fase do processo de reparo referente à fase inflamatória, mas existem indícios ao longo das análises tanto macroscópicas e histológicas que o processo de reparo referente as fases subsequentes de proliferação e remodelamento estão iniciando-se em paralelo. A mistura M4 em ambas as emulsões apresentou elevada quantidade de formação de PPIX em menor tempo de incubação. M4 em emulsão O/A apresentou menor dano fotodinâmico já que a evolução do processo reparo foi mais rápida sugerindo-se potencial de aplicação em TFD voltado para área cosmética-estética. Já M4 em emulsão A/O levou a um maior dano fotodinâmico já que a evolução do processo de reparo foi mais lenta sugerindo-se potencial de aplicação em TFD voltado para área oncológica e de doenças de pele. De modo geral o estudo proposto apresentou impacto positivo para a otimização da terapia fotodinâmica em aplicação tópica. / Photodynamic therapy (PDT) using 5-aminolevulinic acid and derivatives on topical application and as a precursor of protoporphyrin (PPIX) has some limitations for low permeation of substances into the skin. This behavior affects PPIX production and homogeneous distribution on the surface and deeper layers of the skin. To resolve this limitation, many authors propose alternatives such as modifying the molecule of ALA and its derivatives, as well as changing the chemical properties of the external phase of the emulsion (more hydrophilic or hydrophobic) or the delivery system to the emulsion. The aim of this study is to assess the proportion of ALA and methyl-5-aminolevulinate (MAL) that when mixed leads to an increase in the amount and uniformity of the PPIX formation on surface and deep skin. For this study we performed fluorescence analysis and histology. The studies were conducted in vivo and also using pig skin biopsies (ex vivo) cultured in vitro. The PPIX production was monitored using fluorescence spectroscopy, widefield fluorescence imaging, and fluorescence confocal microscopy. For the application of PDT an intensity of 125 mW/cm2 and a dose 150 J/cm2 were used. Analysis of the damage caused by irradiation was performed through skin histology after 24 and 48 hours after PDT application. ALA and MAL in concentration of 20% were mixed in the following proportions: ALA or M, M2 (80% ALA - 20% MAL), M3 (60% ALA - 40% MAL), M4 (50% ALA - MAL) M5 (40% ALA - 60% MAL), M6 (20% ALA - 80% MAL) MAL and as M7. Different proportions were incorporated in oil-in-water emulsions (O/W) and water-in-oil (W/O). The fluorescence measurements for 3h of incubation showed better PPIX production in the skin surface for mixtures M3, M4 and M5. Moreover, the kinetics study showed PPIX production in less time for these mixtures. In the study of cream permeation of ex vivo skin in vitro by confocal fluorescence microscopy, we observed that the mixtures M3, M4 and M5 produced more PPIX in the skin layers than ALA and MAL. The histological analyses of the mixtures showed higher photodynamic damage on the surface and deeper layers of the skin after PDT, independent of the emulsion. The analysis in 48 hours predominantly observed the phase of the healing process regarding the inflammatory phase but there are signs along both macroscopic and histological analysis that the healing process concerning the subsequent stages of proliferation and remodeling are initiating in parallel. The mixture M4 in both emulsions had high amounts of PPIX formation in shorter incubation time. M4 emulsion O/A showed a lower photodynamic damage since the evolution of the healing process was faster suggesting to potential application in PDT facing cosmetic-aesthetic area. M4 already in W/O emulsion led to a greater photodynamic damage since the evolution of the healing process was slower suggesting to potential application in PDT facing oncology and skin diseases. Overall the proposed study had a positive impact on the optimization of photodynamic therapy for topical application.
137

Avaliação do efeito fotodinâmico a partir da associação dos precursores da PPIX (ALA e MAL) em epitélio suíno / Photodynamic effect evaluation from the association of the precursors of PPIX (ALA and MAL) in swine epithelium

Alessandra Keiko Lima Fujita 23 May 2016 (has links)
A terapia fotodinâmica (TFD) utilizando ácido 5-aminolevulinico (ALA) e derivados em aplicação tópica e, como precursor da protoporfirina IX (PPIX) apresenta alguns limitantes relativos a baixa permeação das substâncias na pele. Comportamento este que afeta a produção e homogeneidade da distribuição da PPIX na superfície e camadas mais profundas da pele. Para resolver essa limitação muitos autores propõem alternativas modificando a molécula do ALA e derivados, bem como modificando as propriedades químicas da fase externa da emulsão (mais hidrofílica ou hidrofóbica) ou então o sistema de entrega para a emulsão. O objetivo desse estudo é avaliar qual a proporção de ALA e metil-5-aminolevulinato (MAL) que quando misturados levam ao aumento da quantidade e uniformidade da formação da PPIX na superfície e em profundidade na pele. Para esse estudo foi realizada análises de fluorescência e histologia. O estudo foi conduzido in vivo e ex vivo usando biópsias de pele de porco cultivadas in vitro. A produção de PPIX foi monitorada utilizando espectroscopia de fluorescência, imagem de fluorescência de campo amplo e microscopia confocal de fluorescência. E para a aplicação da TFD os parâmetros usados foram de 125 mW/cm2 de intensidade e 150 J/cm2 de dose. A análise do dano causado pela irradiação foi realizada por meio de histologia da pele após 24 e 48 horas da aplicação da TFD. O ALA e MAL na concentração de 20% foram misturados nas seguintes proporções: ALA ou M, M2 (80% ALA - 20% MAL), M3 (60% ALA 40% MAL), M4 (50% ALA MAL), M5 (40% ALA 60% MAL), M6 (20% ALA 80% MAL) e MAL como M7. As diferentes proporções foram incorporadas em emulsões óleo em água (O/A) e água em óleo (A/O). De acordo com os resultados, as misturas M3, M4 e M5 mostraram maior produção de PPIX na superfície da pele segundo as medidas de fluorescência em 3h de incubação e, no estudo da cinética mostraram produzir PPIX em menor tempo. No estudo de permeação do creme in vitro em pele ex vivo, por microscopia confocal de fluorescência, observou-se que as misturas M3, M4 e M5 produziram mais PPIX nas camadas da pele do que ALA e MAL. As análises histológicas das misturas apresentaram maior dano fotodinâmico na superfície e profundidade das camadas da pele após a TFD, independente da emulsão. A análise em até 48h observou-se predominantemente a fase do processo de reparo referente à fase inflamatória, mas existem indícios ao longo das análises tanto macroscópicas e histológicas que o processo de reparo referente as fases subsequentes de proliferação e remodelamento estão iniciando-se em paralelo. A mistura M4 em ambas as emulsões apresentou elevada quantidade de formação de PPIX em menor tempo de incubação. M4 em emulsão O/A apresentou menor dano fotodinâmico já que a evolução do processo reparo foi mais rápida sugerindo-se potencial de aplicação em TFD voltado para área cosmética-estética. Já M4 em emulsão A/O levou a um maior dano fotodinâmico já que a evolução do processo de reparo foi mais lenta sugerindo-se potencial de aplicação em TFD voltado para área oncológica e de doenças de pele. De modo geral o estudo proposto apresentou impacto positivo para a otimização da terapia fotodinâmica em aplicação tópica. / Photodynamic therapy (PDT) using 5-aminolevulinic acid and derivatives on topical application and as a precursor of protoporphyrin (PPIX) has some limitations for low permeation of substances into the skin. This behavior affects PPIX production and homogeneous distribution on the surface and deeper layers of the skin. To resolve this limitation, many authors propose alternatives such as modifying the molecule of ALA and its derivatives, as well as changing the chemical properties of the external phase of the emulsion (more hydrophilic or hydrophobic) or the delivery system to the emulsion. The aim of this study is to assess the proportion of ALA and methyl-5-aminolevulinate (MAL) that when mixed leads to an increase in the amount and uniformity of the PPIX formation on surface and deep skin. For this study we performed fluorescence analysis and histology. The studies were conducted in vivo and also using pig skin biopsies (ex vivo) cultured in vitro. The PPIX production was monitored using fluorescence spectroscopy, widefield fluorescence imaging, and fluorescence confocal microscopy. For the application of PDT an intensity of 125 mW/cm2 and a dose 150 J/cm2 were used. Analysis of the damage caused by irradiation was performed through skin histology after 24 and 48 hours after PDT application. ALA and MAL in concentration of 20% were mixed in the following proportions: ALA or M, M2 (80% ALA - 20% MAL), M3 (60% ALA - 40% MAL), M4 (50% ALA - MAL) M5 (40% ALA - 60% MAL), M6 (20% ALA - 80% MAL) MAL and as M7. Different proportions were incorporated in oil-in-water emulsions (O/W) and water-in-oil (W/O). The fluorescence measurements for 3h of incubation showed better PPIX production in the skin surface for mixtures M3, M4 and M5. Moreover, the kinetics study showed PPIX production in less time for these mixtures. In the study of cream permeation of ex vivo skin in vitro by confocal fluorescence microscopy, we observed that the mixtures M3, M4 and M5 produced more PPIX in the skin layers than ALA and MAL. The histological analyses of the mixtures showed higher photodynamic damage on the surface and deeper layers of the skin after PDT, independent of the emulsion. The analysis in 48 hours predominantly observed the phase of the healing process regarding the inflammatory phase but there are signs along both macroscopic and histological analysis that the healing process concerning the subsequent stages of proliferation and remodeling are initiating in parallel. The mixture M4 in both emulsions had high amounts of PPIX formation in shorter incubation time. M4 emulsion O/A showed a lower photodynamic damage since the evolution of the healing process was faster suggesting to potential application in PDT facing cosmetic-aesthetic area. M4 already in W/O emulsion led to a greater photodynamic damage since the evolution of the healing process was slower suggesting to potential application in PDT facing oncology and skin diseases. Overall the proposed study had a positive impact on the optimization of photodynamic therapy for topical application.
138

Fluorescência no diagnóstico da cárie / Fluorescence for the caries diagnostics

Figueiredo, Augusto César Ribeiro 28 March 2003 (has links)
A incorporação de novas ferramentas na área de saúde tem promovido uma grande atividade interdisciplinar. A Odontologia tem sido uma dessas áreas beneficiadas com a incorporação de novas tecnologias, principalmente, na área de detecção de cáries. Atualmente, a tecnologia para uso da fluorescência no diagnóstico da cárie utiliza apenas um comprimento de onda no espectro da fluorescência, relacionando com a intensidade, para a determinação da presença ou ausência de tecido cariado. No entanto, deve ser analisado o espectro de fluorescência como um todo e não a fluorescência em um único ponto, pois todos os comprimentos de onda na fluorescência contêm a informação mais precisa sobre a existência ou não de cárie. Neste trabalho descrevemos uma maneira de processarmos a fluorescência para diagnosticar com mais precisão a existência de cárie, para isso, estudamos o comportamento da fluorescência do esmalte e dentina sadios e dentina cariada através de duas formas de processamento dessa fluorescência, sendo primeiramente através da razão do pico elástico pelo pico inelástico e a razão da área inelástica pela área elástica. Utilizamos dentes que apresentavam esmalte e dentina sem cárie e uma face com dentina cariada que foram excitados com três fontes de laser com 442nm, 532nm e 632nm. Foi possível determinar que os três comprimentos de onda foram eficientes na detecção de cárie, porém quando os tecidos foram excitados com 442nm e 632nm os resultados apresentaram os melhores contrastes, além disso, apresentamos um segundo experimento, onde medimos a fluorescência do esmalte sadio com o aparelho comercial Diagnodent® antes e depois da irradiação com o laser de Er: YAG e mostramos que o aparelho mostra erros nessas medidas acusando cárie em esmalte sadio irradiado com o laser, isso identifica um problema quando a fluorescência é captada em um único comprimento de onda / The introduction of new tools in medicine has promoted an important interdisciplinar activity. In Dentistry, the improvement induced by this new technology is mainly observed at caries detection. Until now, the fluorescence procedure for caries detection is based on the investigation of only a specific region of the fluorescencespectrum. From this analysis the presence of caries or healthy tissues is inferred. However, all the fluorescence spectrum must be evaluated and not only a small part of it. The collected information will be important to the caries diagnosis. In this work we propose two ways to process the fluorescence spectrum in order to obtain a more accurate diagnosis. In this way, we study the fluorescence behavior of health enamel and healthy and decayed dentin. The fist way to process the fluorescence here proposed is obtained by the ratio of inelastic peak and elastic peak and the second one, the ratio of the inelastic and elastic areas. It were investigated human teeth with healthy enamel, decayed and healthy dentin surfaces at the same sample. The fluorescence was induced by three lasers excitation: 442nm, 532nm and 632nm. Ali the used wavelengths showed to be efficient for caries detection, however 442nm and 632nm presented better contrasts. A second study was performed, when the fluorescence of healthy enamel was investigated using a commercial device (Diagnodent®) previously and after Er: YAG irradiation. It was demonstrated that this device can present divergent results showing a caries diagnosis for a healthy irradiated enamel surface. This result identifies a problem when a single wavelength is evaluated from all the fluorescence spectrum
139

Liberação de compostos orgânicos das resinas KaloreTM e FiltekTM Silorane em função da fonte de luz polimerizadora, dos meios de imersão e do pH / Release of organic resins KaloreTM and FiltekTM Silorane according to the source of curing light, the immersion solution and pH

Pieroni, Karina Alessandra Michelão Grecca 13 June 2013 (has links)
Compostos orgânicos podem ser liberados dos materiais resinosos, mesmo após sua polimerização, como resultado da presença de monômeros residuais e do processo de degradação do próprio material, podendo ocasionar efeitos citotóxicos, genotóxicos e alergênicos. O objetivo do presente estudo, in vitro, foi avaliar a liberação de compostos orgânicos de dois materiais resinosos, recentemente lançados no mercado, que apresentam inovações em suas formulações (resinas Kalore TM - GC FUJI e FiltekTM Silorane - 3M ESPE), variando a fonte de luz polimerizadora (halógena ou LED), a solução de imersão (água ou saliva artificial) e o pH da solução de imersão (7 ou 4,5). Foram confeccionados 56 corpos de prova da resina Kalore TM e 56 da resina FiltekTM Silorane, sendo 28 polimerizados com luz halógena e 28 com luz LED. Após aleatorização, 7 corpos de prova de cada resina foram armazenados em água com pH neutro, 7 em água com pH ácido, 7 em saliva com pH neutro e 7 em saliva com pH ácido. A leitura dos espectros das soluções foi realizada por meio da espectroscopia de fluorescência após 1, 3, 24, 48, 72, 168, 216, 312, 432, 504 e 672 horas. Após 672 horas, ainda verificou-se a liberação de compostos orgânicos das resinas KaloreTM e FiltekTM Silorane em todas as condições avaliadas. A liberação de compostos orgânicos foi menor nos grupos experimentais polimerizados pela luz LED. A quantidade de compostos orgânicos liberados foi menor nas amostras imersas em saliva. A resina KaloreTM liberou uma quantidade maior de compostos orgânicos em pH neutro, independente do meio de imersão. A resina FiltekTMSilorane liberou uma quantidade maior de compostos orgânicos em pH ácido, quando imersas em água, e uma maior quantidade de compostos orgânicos em pH neutro, quando imersas em saliva. A resina FiltekTMSilorane liberou mais de um componente orgânico. A espectrometria de fluorescência permitiu avaliar a liberação de compostos orgânicos das resinas KaloreTM e FiltekTM Silorane. / Organic compounds may be released from the resin materials, even after polymerization, as a result of the presence of residual monomers and degradation of the material itself, which may cause cytotoxic, genotoxic and allergenics effects. The purpose of this study, in vitro, was to evaluate the release of organic compounds from two resin materials, recently launched on the market, that present innovations in their formulations (resins KaloreTM - GC FUJI and FiltekTM Silorane - 3M ESPE), varying the source curing light (LED or halogen), the immersion solution (water or artificial saliva) and the pH of the immersion solution (7 or 4.5). Were prepared 56 specimens resin KaloreTM and 56 resin FiltekTM Silorane, 28 polymerized with halogen light and 28 with LED light. After randomization, 7 samples of each resin were immersed in water at neutral pH, 7 in water at acid pH, 7 in the saliva at a neutral pH, and 7 in the saliva at acid pH. The reading of the spectra of the solutions was performed by fluorescence spectroscopy at 1, 3, 24, 48, 72, 168, 216, 312, 432, 504 and 672 hours. After 672 hours, there was still release of organic resins KaloreTM and FiltekTM Silorane under all conditions evaluated. The release of organic compounds was lower in the experimental groups polymerized by LED light. The amount of organic compounds released was lower in samples immersed in saliva. The resin KaloreTM released more organic compounds at neutral pH in both immersion media. The resin FiltekTMSilorane immersed in water released more organic compounds at acid pH, but when the resin was immersed in saliva the release of organic compounds was higher at neutral pH. The resin FiltekTMSilorane released more that one organic component. The fluorescence spectrometry allowed us to evaluate the release of organic compounds resins KaloreTM and FiltekTMSilorane.
140

Imagens e espectroscopia de fluorescência na agricultura: um estudo sobre o diagnóstico de doenças e fenotipagem / Images and fluorescence spectroscopy in agriculture: a study on the diagnosis of diseases and phenotyping

Kubota, Thiago Massaiti Kuboyama 29 November 2017 (has links)
Com uma grande diversidade climática, 13% de toda a água doce do mundo em seu território, abundância na energia solar e chuvas regulares, o Brasil é um país favorável para o desenvolvimento da agropecuária. Segundo o Ministério da Agricultura, Pecuária e Abastecimento (MAPA) as vendas do setor do Agronegócio brasileiro, de janeiro até julho de 2016, alcançaram US$ 52,8 bilhões, respondendo por 49% de todas as exportações do país. Dois produtos que contribuem decisivamente para este sucesso são a soja e a laranja, onde o Brasil se enquadra como grande produtor e exportador. Um fator que pode comprometer o crescimento do setor do agronegócio são as pragas e doenças. Neste trabalho foram utilizadas técnicas de imagens e espectroscopia de fluorescência como ferramentas de diagnóstico de doenças e fenotipagem. As culturas estudadas, por sua relevância econômica, foram os citros e a soja. Foram investigadas folhas de laranja sadias e doentes com Huanglongbing (HLB), conhecida também como Greening e folhas de soja sadias e doentes com Green StemandFoliar Retention (GSFR), popularmente conhecida como Soja Louca II. Com base em descritores retirados dos espectros e das imagens foram desenvolvidos classificadores utilizando-se a Regressão por Mínimos Quadrados Parciais (PLSR). O desempenho dos classificadores para diferenciar folhas de soja doentes de folhas sadias alcançou 99% para o sistema de espectroscopia de fluorescência e 100% para o sistema de Imagens de Fluorescência. Já com o sistema de imagens de Refletância com Luz Polarizada o acerto na classificação correta entre folhas de laranja sadias e com HLB foi de 84%. Também foi estudada a possibilidade de utilização de imagens termais em diferentes situações de estresse hídrico e nutricional. Através deste sistema foi possível detectar plantas em condições de estresses hídricos decorridos dois dias após o corte de água. As técnicas acima mencionadas também foram testadas para fenotipagem de plantas. Foram analisadas 20 variedades diferentes de citros e 3 de soja. A taxa de acerto na diferenciação de citros geneticamente muito próximos ficou em torno de 63% e para soja foi alcançado 95%, isso quando empregado o sistema de espectroscopia de fluorescência. Com base nesses resultados é possível afirmar que as técnicasfotônicas combinadas com os modelos classificadores, podem ser utilizadas como ferramentas para diagnosticar as doenças, como a GSFR e o HLB, e avaliar diferentes tipos de estresse abiótico. Elas também podem ser utilizadas para diferenciar variedades de plantas, mesmo no caso de variedades muito próximas geneticamente, onde as técnicas tradicionais não são capazes de fazê-lo. Os resultados apresentados foram promissores e podem, em um futuro próximo, gerar sistemas portáteis que devem auxiliar os produtores no campo. / With a great climatic diversity, 13% of all the fresh water of the world in its territory, abundance in solar energy and regular rains, Brazil is a favorable country for the development of agriculture. According to the Ministry of Agriculture, Livestock, and Supply (MAPA), sales of the Brazilian Agribusiness sector, from January to July 2016, reached US$ 52.8 billion, accounting for 49% of all Brazilian exports. Two products that contribute decisively to this success are soy and orange, where Brazil is a major producer and exporter. One factor that can jeopardize the growth of the agribusiness sector is pests and diseases. In this work, fluorescence spectroscopy and imaging techniques were used as tools for the diagnosis of diseases and phenotyping. The crops studied, because of their economic relevance, were citrus and soybean. Healthy and infected leaves with Huanglongbing (HLB), also known as Greening, and healthy and infected leaves with Green Stem and Foliar Retention (GSFR), popularly known as Mad Soybean II, were investigated. Based on descriptors taken from spectra and images, classifiers were developed using Partial Least Squares Regression (PLSR). The performance of the classifiers to differentiate diseased leaves from healthy leaves reached 99% for the fluorescence spectroscopy system and 100% for the Fluorescence Imaging system. The success rate of classification for the system using polarized reflectance images reached 84%. We also studied the possibility of using thermal images in different situations of water and nutritional stress. Through this system, it was possible to detect plants in conditions of water stress after two days of water cut. The techniques above mentioned were also tested for plant phenotyping. Twenty different citrus and three soybean varieties were analyzed. The success rate of the differentiation using fluorescence spectroscopy for very close citrus was around 63% and for soybean was reached 95%. Based on these results it is possible to conclude that the photonic techniques combined with the classifier models can be used as tools to diagnose diseases such as GSFR and HLB and to evaluate different types of abiotic stress. They can also be used to differentiate plant varieties, even in the case of very closely varieties, where traditional techniques are not able to carry out. The results presented were promising and may, in the near future, generate portable systems that should assist farmers in the field.

Page generated in 0.0871 seconds