• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 164
  • 48
  • 16
  • Tagged with
  • 225
  • 225
  • 201
  • 107
  • 95
  • 60
  • 44
  • 40
  • 32
  • 31
  • 31
  • 28
  • 19
  • 18
  • 18
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

Influence de l'élasticité du substrat sur la genèse, propagation et coalescence des structures de cloquage de revêtements et films minces. / Influence of the elasticity of the substrate on the genesis, propagation and coalescence of coatings and thin films buckling structures.

Boijoux, Romain 23 November 2017 (has links)
Le cloquage des films minces est un enjeu scientifique et industriel de premier plan, dans la mesure où il correspond au premier stade du délaminage a grande échelle du film, aboutissant généralement à la perte des propriétés fonctionnelles initialement conférées au matériau revêtu.L'influence de la souplesse du substrat sur ce phénomène est peu comprise à ce jour, alors que les systèmes industriels composés de films rigides sur substrats souples se multiplient. Cette étude se focalisera ainsi principalement sur l’influence de l’élasticité du substrat sur la genèse, propagation et coalescence des structures de cloquage, . L’approche expérimentale sera de générer des structures de cloquage élémentaires, de type ride droite, bulle ou « cordon de téléphone », et d’en contrôler la propagation, de manière à les faire interagir, se croiser, voire coalescer. La caractérisation morphologique de ces structures de cloquage se fera par microscopie à force atomique. Ces résultats expérimentaux seront confrontés à des simulations numériques par éléments finis réalisées en parallèle, permettant de tenir compte du couplage entre flambage du revêtement et délaminage de l’interface film/substrat. Les résultats obtenus permettront de mieux appréhender le phénomène de cloquage des revêtements et films minces. Cette étude répond ainsi principalement à trois questions : quelle est l’influence de l’élasticité du substrat sur la dynamique de propagation des cloques ? Comment se produisent leurs croisements aboutissant à des structures parfois singulières ? Cette élasticité favorise-t-elle la coalescence des cloques en cours de propagation, même si celles-ci ne se rencontreraient pas d’un point de vue purement balistique ?Enfin, l’intérêt technologique s’inscrit dans une démarche environnementale qui consiste à identifier les paramètres pertinents permettant d’inhiber le processus de cloquage, de le limiter, voire de le contrôler pour améliorer la durabilité des systèmes industriels. / Thin films buckling is a scientific and industrial challenge of primary importance, since it correspond to the first stage of the buckling of the film at a large scale, leading to the loss of the mechanical property initially conferred to the coated material.The influence of the substrate elasticity on this phenomenon is not well understood today, whereas the proportion of industrial systems made of rigid films on soft substrates increase. This study focus principally on the influence of the substrate elasticity on the genesis, propagation and coalescence of the buckled structures. The experimental approach consist in the controlled generation of elementary buckling structures, such as straight-sided buckles, blisters or “telephone cords” buckles, to make them interact and even meet and merge each other. The morphological characterization of such buckling structures will be performed by the atomic force microscopy technique. These experimental results will be then compared to finite elements simulations performed together, allowing to take into account the coupling between the buckling of the film and the film/substrate interface delamination. The obtained results will allow a better understanding of the coating and thin film buckling phenomenon. Thus, this study answer in particular to three questions : how the substrate elasticity impact the propagation dynamic of the buckles ? How their crossing occur, leading sometimes to complex structures ? Is this elasticity helps the coalescence of the buckles, even if they does not match each other in a “ballistic” way ?Finally, the technological goal is part of an environmental approach that consist in identifying the parameters that can suppress, limit or control the buckling phenomenon for specific applications.
122

Towards the use of electrostatic force microscopy to study interphases in nanodielectric materials / Vers l'utilisation du microscope à force électrostatique pour l'étude des interphases dans les matériaux nanodiélectriques

El Khoury, Diana 17 November 2017 (has links)
Les interphases sont souvent considérées comme responsables des propriétés physiques des nanodiélectriques inexplicables par les lois de mélange. La prédiction de la permittivité diélectrique des nanodiélectriques nécessite de reconsidérer la permittivité intrinsèque et le volume de l'interphase. Malgré le besoin d'une caractérisation locale de ces régions interfaciales nanométriques, aucune méthode expérimentale fiable n'a encore été développée. La Microscopie à Force Electrostatique (EFM) constitue une technique prometteuse pour atteindre ce but. L'objectif de cette thèse est de développer des protocoles expérimentaux et des méthodes d’interprétations du signal appropriés pour évaluer l’aptitude de l’EFM à l'étude des interphases dans les nanodiélectriques. Nous avons eu recours d’abord à des simulations numériques par éléments-finis pour approfondir notre compréhension de l'interaction entre une sonde EFM et plusieurs types d'échantillons nanostructurés, permettant par la suite de simuler la réponse spécifique face à un nanocomposite possédant une interphase. Nous avons proposé un modèle électrostatique de nanodiélectrique possédant trois phases, selon lequel, nous avons conçu et synthétisé des échantillons modèles aux propriétés connues afin de jouer le rôle de matériaux nanodiélectriques de référence pour les mesures EFM. Par conséquent, nous avons pu développer plusieurs protocoles expérimentaux et d’analyses du signal utilisant des modes DC et AC de détection du gradient de force pour caractériser les interphases dans des nanocomposites. Ces techniques constituent un ensemble polyvalent de méthodes d’étude des interphases avec un impact réduit des effets parasites communément convolués dans les signaux EFM. Enfin, une quantification de la permittivité de l'interphase de nos échantillons modèles a été possible par corrélation avec nos simulations numériques. / Interphases are usually considered to be responsible for the physical properties of nanodielectrics unexplainable by general mixture laws. The prediction of the effective dielectric permittivity of these materials needs to reconsider the intrinsic permittivity and the volume of the interphase. Despite the urge for a local characterization of these nanometric interfacial regions, no reliable experimental method has been developed yet. The Electrostatic Force Microscope (EFM) constitutes a promising technique to fulfill this objective. The aim of this thesis is to develop appropriate experimental protocols and signal analysis to explore the ability of EFM to the study of interphases in nanodielectrics. We first resorted to finite-element numerical simulations in order to deeper our understanding of the interaction between an EFM probe and several types of nanostructured samples, allowing to simulate afterwards the specific response to a nanocomposite possessing an interphase. We proposed a three-phase electrostatic model of a nanodielectric, upon which, we designed and synthesized model samples of known properties to play the role of a reference nanodielectric material for EFM measurements. Consequently, we were able to develop several experimental protocols and signal analysis with both DC and AC force gradient EFM modes. These techniques offer versatile methods to characterize interphases with reduced impact of the parasitic effects commonly convoluted within EFM signals. Finally, a quantification of the interphase in our nanodielectric model samples was possible thanks to correlation with our numerical simulations.
123

AFM à contact résonant : développement et modélisation / Contact resonant AFM : development and Modeling

Mege, Fabrice 20 May 2011 (has links)
Avec l'intégration de circuits intégrés de plus en plus denses, le besoin d'outils de caractérisation adaptés à ces échelles se fait ressentir. Identifier et analyser les problèmes de fiabilité survenant dans ces structures à des dimensions inférieures à 100 nm demande la mise au point d'instruments innovants. Ce travail de thèse a consisté dans un premier temps à développer un appareil à champs proches sensible aux propriétés mécaniques de surface, et dans un second temps à analyser les résultats expérimentaux en s'appuyant sur des approches analytiques et/ou numériques. Désigné sous le nom de microscope à force atomique à résonance de contact (CR-AFM), cet appareil est sensible à la rigidité effective de films minces sur substrat, ce qui lui permet de cartographier la rigidité mécanique de films minces. Nous avons mené un important travail de développement instrumental afin d'obtenir des résultats expérimentaux répétables et fiables, condition indispensable à une analyse quantitative. Puis nous avons utilisé le CR-AFM sur divers échantillons : empilements modèles (films de silice sur silicium, avec épaisseurs variables de silice), films de silice avec porosité variable, structures damascènes d'interconnexion cuivre,… Des images traduisant les variations d'élasticité de surface ont ainsi pu être construites. Pour quantifier ces variations, nous avons analysé nos résultats à l'aide de différents modèles (approches analytiques et numériques). Des simulations par éléments finis ont été réalisées pour étayer ces résultats. / The reduction of feature size in integrated circuits has raised an increasing need for characterization tools displaying small-scale resolution. Reliability issues taking place in these structures with dimensions below 100 nm require the development of innovative instruments. This thesis has first focused on the development of near field apparatus displaying sensitivity to surface mechanical properties. Afterwards analytical and numerical modelings have been developed to analyze the obtained experimental data. Known as contact resonance atomic force microscope (CR-AFM), this apparatus is sensitive to the effective stiffness of thin film on substrate, allowing the mapping of the mechanical stiffness. A significant work on the apparatus setting-up and procedure has been done to obtain repeatable and reliable experimental data, which is a prerequisite for quantitative analysis. Then CR-AFM experiments have been done on various samples: model stacks (silica thin films on silicon with varying silica thickness), silica films with tuned porosity, Damascene copper interconnect structures,… The mapping of elastic stiffness of such samples has been built-up. In order to quantify these contrasts, our experimental results have been analyzed through different models (analytical and numerical). Finite element simulations were also performed to support these results.
124

Étude de l'influence du récepteur LRP-1 sur le potentiel invasif de cellules tumorales : mesures nanomécaniques et d'adhérence par microscopie à force atomique / Study of the influence of the LRP-1 receptor on the invasive potential of cancer cells : nanomechanical and adhesion measurements by atomic force microscopy

Le cigne, Anthony 01 July 2016 (has links)
Le récepteur low-density lipoprotein receptor-related protein 1 (LRP-1) est capable d’internaliser des protéases impliquées dans la progression du cancer, et constitue donc une cible thérapeutique prometteuse. Cependant, LRP-1 peut également réguler certaines protéines membranaires. Son ciblage dans une stratégie de modulation de la protéolyse pourrait donc affecter l’adhésion et la dynamique du cytosquelette. Dans ce travail, nous avons étudié l’influence de l’invalidation de LRP-1 sur des paramètres originaux corrélés au potentiel invasif de cellules cancéreuses par microscopie à force atomique (AFM). Cette invalidation induit des changements dans la dynamique d’adhérence des cellules et dans la morphologie, tels qu’un renforcement des fibres de stress et un étalement plus prononcé, causant une augmentation de la surface et de la circularité cellulaires. L’analyse des propriétés mécaniques par AFM a montré que ces différences sont acccompagnées par une augmentation du module d’Young. De plus, les mesures montrent une diminution globale de la motilité cellulaire et une perturbation de la persistance directionnelle. Une augmentation de la force d’adhésion entre cellules invalidées pour LRP-1 et une bille fonctionnalisée à la gélatine a également été observée. Enfin, nos données de spectroscopie de force enregistrées à l’aide d’une pointe fonctionnalisée par un anticorps anti-sous-unité d’intégrine β1 montrent que l’invalidation de LRP-1 modifie la dynamique des intégrines. Dans leur ensemble, nos résultats montrent que des techniques classiquement utilisées dans l’investigation de cellules cancéreuses peuvent être couplées à l’AFM pour ouvrir l’accès à des paramètres complémentaires, pouvant faciliter la discrimination entre différents degrés de potentiel invasif. / The low-density lipoprotein receptor-related protein 1 (LRP-1) can internalize proteases involved in cancer progression and is thus considered a promising therapeutic target. However, it has been demonstrated that LRP-1 is also able to regulate membrane-anchored proteins. Thus, strategies that target LRP-1 to modulate proteolysis could also affect adhesion and cytoskeleton dynamics. Here, we investigated the effect of LRP-1 silencing on parameters reflecting cancer cells’ invasiveness by atomic force microscopy (AFM). The results show that LRP-1 silencing induces changes in the cells’ adhesion behavior, particularly the dynamics of cell attachment. Clear alterations in morphology, such as more pronounced stress fibers and increased spreading, leading to increased area and circularity, were also observed. The determination of the cells’ mechanical properties by AFM showed that these differences are correlated with an increase in Young’s modulus. Moreover, the measurements show an overall decrease in cell motility and modifications of directional persistence. An overall increase in the adhesion force between the LRP-1-silenced cells and a gelatin-coated bead was also observed. Ultimately, our AFM-based force spectroscopy data, recorded using an antibody directed against the β1 integrin subunit, provide evidence that LRP-1 silencing modifies integrin dynamics. Together, our results show that techniques traditionally used for the investigation of cancer cells can be coupled with AFM to gain access to complementary phenotypic parameters that can help discriminate between specific phenotypes associated with different degrees of invasiveness.
125

Modular polyoxometalate architectures for solar energy conversion / Architectures polyoxometallates modulables pour la conversion de l'énergie solaire

Zhu, Qirong 20 September 2016 (has links)
Les travaux présentés s'inscrivent dans les thèmes de l'électronique moléculaire et de la conversion photovoltaïque. Nous étudierons plus précisément les interactions électroniques à l'interface entre l'électrode anodique et une fine couche de polyoxométallates, POM. Nous dédirons le premier chapitre à une structure de POM qui sera étudiée en détail. Nous démontrerons que dans des conditions de concentration, recuit thermique appropriées la couche atteint un haut degré d'organisation la rendant conductrice. Après une analyse XPS/UPS fine nous montrons que les mécanismes de conduction prennent place sur la couche externe du POM dans les oxygènes lacunaires. De plus ces lacunes d'oxygène génèrent des états autorisés dans le gap interdit sous le niveau de Fermi. Une deuxième étape du travail consistera a étudié les effets des contreions sur la structure électronique précédemment décrite. Dans ce chapitre démontrons que les contreions, souvent décrits comme des espèces spectatrices, influence grandement le comportement électronique d'une espèce de POM. Puis nous étudierons l'impact de la nature du métal constituant le polyoxométallate. Enfin nous ferons dans un dernier chapitre une synthèse des résultats obtenus qui nous permettrons de conclure au regard des hypothèses formulées en présentant des tests de validation photovoltaïques. / In this work, the main objective were to understand the electronic processes of polyoxometalates solid films at an indium tin oxide interface. A well-organized polyoxometalate film was deposited onto ITO and with an appropriate annealing process a highly ordered conductive surface was observed. The anisotropic morphology has been proved to be able to optimize electrical/electronic properties and further improve hole transport in organic photovoltaic devices by inserting as anode interfacial layer. We demonstrated the conductivity took place at the outer shell of the polyoxometalate due to oxygen vacancies which generate very localized gap state. We pursue the study by investigating the counter-ions (K+, Li+ and H+) effect on the identical polyoxoanion [P2W18O62]6-. We show it can not only influence the film aggregation mechanism, but allow tuning the density of gap states. The substitution of tungsten, especially by molybdenum, result in a more favorable energy level alignment from ITO and P3HT, i.e. desirable position and higher density of gap states. In a last we integrated the polyoxometalate in organic solar cells to prove the previous demonstration.
126

Analyse quantitative et qualitative sur puce de vésicules extracellulaires en milieux complexes au sein d'une plateforme nanobioanalytique / On-chip analysis and nanometrology of blood microparticles with label-free detection and characterization techniques

Obeid, Sameh 11 May 2017 (has links)
Les vésicules extracellulaires (VEs) sont des nanovésicules circulantes (30 à 100nm de diamètre) libérées dans l'espace extracellulaire par la plupart des cellules humaines, suite à leur activation ou à leur apoptose. Les VEs se divisent en 3 grandes catégories ; les exosomes (Exo), les microparticules (MPs) et les corps apoptotiques (cAPO). Les VEs sont présentes à l'état physiologique dans les différents fluides biologiques du corps humain et jouent un rôle majeur dans différents processus physio-pathologiques. De nos jours, plusieurs techniques, certaines en routine, sont utilisées pour étudier les VEs. Cependant, aucune d'entre elles ne permet de déterminer à la fois leur concentration, leur taille et leurs caractéristiques biochimiques. Un consensus existe sur la nécessité de combiner des techniques pour disposer enfin d'une caractérisation fine et complète des VEs. Il est d'un intérêt majeur de développer des plateformes analytiques dédiées à ces VEs en vue d'améliorer la qualification des échantillons biologiques et de découvrir de nouveaux biomarqueurs de pathologies humaines ou de bio-indicateurs de suivi thérapeutique.Notre projet consiste à développer une plateforme NanoBioAnalytique (NBA) combinant trois techniques : l'imagerie par Résonance des Plasmons de Surface (SPRi), la Microscopie à Force Atomique (AFM) et la Spectrométrie de Masse (MS). L'enjeu est de développer une interface biopuce-instruments qui permettra d'effectuer des investigations multiphysiques et multiéchelles apportant, en une stratégie globale, les informations plus complètes sur les différentes populations de VEs.[...]Ces travaux ont montré la capacité de notre plateforme à détecter sélectivement, et simultanément, différentes sous-populations des VEs co-existantes dans un échantillon complexe tel que du plasma, en s'appuyant sur l'expression différentielle des marqueurs protéiques membranaires. Les taux de capture se sont avérés être directement corrélés à la concentration des vésicules dans l'échantillon injecté. L'analyse AFM a permis de déterminer la distribution en taille de différentes sous-populations de VEs et permettre une analyse différentielle de la distribution en taille sur la gamme 20 nm - 1000 nm. Enfin, des études protéomiques "sur-puce" ont été également engagées afin de caractériser la composition en protéines des VEs libérées sous différentes conditions. Cette analyse a permis d'établir des premiers profils protéomiques différentiels des VEs dans les échantillons étudiés.La plateforme NBA est une méthode efficace pour caractériser et quantifier les VEs, sans marquage et avec une grande sensibilité, sur une large gamme dynamique (environ 10(7) à 10(12) particules/mL) cohérente avec celle existante en fluide physiologique et sur une plage de taille couvrant 2 décades. Elle s'inscrit parmi les approches les plus prometteuses pour l'investigation des VEs en complément de la cytométrie en flux. La grande adaptabilité de cette méthode d'analyse des VEs ouvre de larges perspectives de déploiement dans les secteurs de la Santé, de l'Environnement et de l'Agro-alimentaire. / Extracellular vesicles (EVs) are small vesicles (30 to 1000 nm) released from different cell types, upon activation or apoptosis, and present in most body fluids (Blood, Urine….). Based on the current state of knowledge of their biogenesis and biochemical properties, EVs can be devided into three distinct populations: exosomes (EXO), microparticles (MPs) and apoptotic bodies (APOb). EVs have been found to play important biological roles and are also biomarkers of different pathologies. […] The first step consists of the injection of the samples containing EVs onto the biochip surface. This step is accomplished by SPR technique that allows label-free monitoring of EVs immunocapture onto the surface of a biochip presenting different specific bioreceptors. Following the capture of EVs, a nanometrological investigation of the biochip surface by AFM is engaged to characterize the physical properties of captured vesicles (size, morphology, etc..). Owning a nanometrical resolution, AFM can discriminate between individual EVs and vesicles or protein aggregates, leading to an accurate characterization of individual vesicles. The coupling of SPR technique with AFM was adapted to offer a representative global view of each array of bioreceptors and to measure the size of thousands of individual EVs. A proteomic investigation was also engaged to characterize the proteomic compositions of the different subpopulations of EVs. Such an investigation could contribute to the understanding of EVs biogenesis, biology and pathophysiology. To evaluate the potential of our platform to detect, quantify and characterize nanoparticles, two calibration particles, which cover the lower and upper size range of EVs, were chosen: (i) virus-like particles of 50 nm of diameter, also called CP50, and (ii) protein-functionnalized synthetic beads of 920 nm of diameter, called CP920. The capture tests in SPR showed a specific capture of these two calibration particles with their specific bioreceptors, immobilized onto the biochip surface, regardless the complexity of the media in which they were diluted. Also, a positive correlation was obtained between the capture level, measured by SPR, and the particle 9
127

Characterization and modification of the mechanical and surface properties at the nanoscale

Tam, Enrico 03 December 2009 (has links)
In the past two decades much effort has been put in the characterization of the mechanical<p>and surface properties at the nano-scale in order to conceive reliable N/MEMS<p>(Nano and Micro ElectroMechanical Systems) applications. Techniques like nanoindentation,<p>nanoscratching, atomic force microscopy have become widely used to measure<p>the mechanical and surface properties of materials at sub-micro or nano scale. Nevertheless,<p>many phenomena such us pile-up and pop-in as well as surface anomalies<p>and roughness play an important role in the accurate determination of the materials<p>properties. The first goal of this report is to study the infulence of these sources of data<p>distortion on the experimental data. The results are discussed in the first experimental<p>chapter.<p>On the other hand, conceptors would like to adapt/tune the mechanical and surface<p>properties as a function of the required application so as to adapt them to the industrial<p>need. Coatings are usually applied to materials to enhance performances and reliability<p>such as better hardness and elastic modulus, chemical resistance and wear resistance.<p>In this work, the magnetron sputtering technique is used to deposit biocompatible thin<p>layers of different compositions (titanium carbide, titanium nitride and amorphous<p>carbon) over a titanium substrate. The goal of this second experimental part is the<p>study of the deposition parameters influence on the resulting mechanical and surface<p>properties.<p>New materials such as nanocrystal superlattices have recently received considerable<p>attention due to their versatile electronic and optical properties. However, this new<p>class of material requires robust mechanical properties to be useful for technological<p>applications. In the third and last experimental chapter, nanoindentation and atomic<p>force microscopy are used to characterize the mechanical behavior of well ordered lead<p>sulfide (PbS) nanocrystal superlattices. The goal of this last chapter is the understanding<p>of the deformation process in order to conceive more reliable nanocrystal<p>superlattices. / Doctorat en Sciences de l'ingénieur / info:eu-repo/semantics/nonPublished
128

La cristallisation du poly(1,3)dioxolanne

Kalala, Bilonda January 2009 (has links)
Mémoire numérisé par la Division de la gestion de documents et des archives de l'Université de Montréal.
129

Lipid layers as ultra-thin dielectric for highly sensitive ions field effect transistor sensors

Kenaan, Ahmad 05 February 2016 (has links)
Cette thèse vise à développer un capteur d’ions cuivre dans des échantillons humains tels que le plasma ou les urines où l’accumulation des ions induit la maladie de Wilson. Le manque d’outil de diagnostic efficace et non invasif rend cette maladie traitable, potentiellement fatale. Notre capteur, basé sur la technologie des transistors à effet de champ de type metal-oxide-semiconducteur, a l’originalité d’utiliser une monocouche de lipide de type DC8,9PC de 2.4 nm d’épaisseur comme diélectrique de grille. Nous démontrons dans cette thèse que ces lipides peuvent être chimiquement modifiés en de monocouches, à stabilité mécanique et électrique élevée, transformées en sondes spécifiques par greffage sur le groupement de tête des lipides d’une fonction chélatante spécifique aux ions cuivre. La monocouche lipidique est formée à la surface du canal semiconducteur du transistor par fusion vésiculaire et est stabilisée par réticulation des lipides suivant un protocole que nous avons développé. Dans une première partie, nous décrivons la fabrication du transistor ainsi que l’ingénierie chimique des lipides avec le chélateur. Des mesures, en solutions aqueuses contenant des ions cuivre et d’autres ions potentiellement compétiteurs, ont validé la sensibilité et la spécificité du capteur. La deuxième partie est dédiée à l’optimisation des monocouches en tant qu’isolants électriques stables. Nous introduisons dans cette thèse la notion de double polymérisation des lipides dans la monocouche avec réticulation des chaînes aliphatiques et des groupements de tête. Nous démontrons que celle-ci conduit à l’amélioration drastique des propriétés mécaniques et électriques des monocouches. / This thesis aims at developing a sensor for the detection of Cu2+ in human samples such as urine. Copper is an ion of pathological interest in the body and its accumulation in tissues is responsible for the Wilson disease. While the disease can be effectively treated, the lack of efficient and non-invasive diagnosis techniques makes it potentially deadly. Our project aims for developing an efficient, sensitive, specific, and low cost sensor device based on metal-oxide-semiconductor field effect transistor technology and has the originality of using a 2.4 nm thick monolayer of DC8,9PC lipids as gate dielectric. We demonstrate that such lipids can be chemically engineered to allow the fabrication of monolayers with high mechanical and electrical stability and to confer them specific probe function. Specificity of the sensor is given by the grafting of a copper specific chelator to the lipids head-groups. The lipid monolayer is formed on the transistor semiconducting channel by the vesicle fusion. In the first part of the thesis, we describe the fabrication of the transistor including the chemical engineering of the lipids with the chelator. Sensitivity and specificity measurements were realized in aqueous solutions containing copper ions and potentially competitive ions. The second part is dedicated to improving the performances of the lipid monolayer as a stable insulator. We introduce in this thesis the concept of double polymerization of the lipids in the monolayer with a reticulation at both the levels of their aliphatic chains and their head-groups. We demonstrate that that leads to drastic improvements of both the mechanical and electrical properties of the monolayer.
130

Characterization of cell mechanics with atomic force microscopy : Mechanical mapping and high-speed microrheology / Charactérisation de la mécanique cellulaire par microscopie à force atomique : cartographie d'élasticité et microrhéologie à grande vitesse

Rigato, Annafrancesca 13 November 2015 (has links)
La mécanique cellulaire a gagné un intérêt croissant en raison de son implication fondamentale dans des nombreux processus cellulaires, notamment la migration, la division, la différentiation et l’apoptose. Entre autres techniques, la microscopie à force atomique (AFM) s’est avérée particulièrement utile pour la caractérisation mécanique des cellules vivantes. Dans cette thèse, deux aspects différents ont été étudiés par AFM. Dans un premier temps, l’élasticité des cellules épithéliales étalées sur des micropatterns adhésifs a été cartographiée. Cette étude montre que l’élasticité d’une cellule varie en fonction de sa géométrie d’adhésion à la fois au niveau global et subcellulaire. La deuxième partie de cette thèse est dédiée à la caractérisation de la réponse viscoélastique d’une cellule à un stimulus mécanique oscillatoire à haute fréquence. Des études précédentes montrent que la réponse des cellules est dominée par un stress élastique et suive une loi de puissance faible à basse fréquence. Une réponse cellulaire essentiellement visqueuse est attendue à haute fréquence, mais jusqu’à présent les limitations techniques ont empêché l’évaluation de cette propriété. Dans ma thèse, ces limitations ont été dépassées grâce à la modification d’un AFM à grande vitesse (HS-AFM). Des mesures de rhéologie active sur fibroblastes ont été réalisées entre 1Hz et 120 kHz, permettant d’étendre de deux ordres de grandeur l’échelle de fréquences explorée. Ce travail montre une réponse cellulaire aux stimulations à haute fréquence plus visqueuse qu’à basse fréquence, mais suggèrent aussi une réponse bien plus complexe qu’attendue. / The field of cell mechanics gained a growing interest because of its fundamental implication in several cellular processes, such as migration, division, differentiation and apoptosis. Among other techniques, atomic force microscopy (AFM) demonstrated particularly useful for the mechanical characterization of living cells. In this thesis, two different aspects were investigated by AFM. In the first part, the elastic properties of epithelial cells grown on adhesive micropatterns were mapped. This study shows that the elasticity of a cell varies as a function of the geometry of its adhesive environment on both global and subcellular scales. The second part of this thesis focuses on the characterization of the viscoelastic response of a cell subjected to an oscillatory mechanical stimulus at high frequency. Previous studies show that the response of cells to such stimuli is mainly dominated by elastic stress and follows a weak power law at low frequency. Instead, a predominantly viscous behavior is expected at high frequency. Up to now, technical limitations prevented the experimental validation of this property. In this thesis, these limitations were overcome thanks to the modification of a high-speed AFM (HS-AFM). With this setup, active rheological measurements of living fibroblasts could be performed from 1 Hz to 120 kHz, extending of two orders of magnitude the frequency scale explored until now. This work highlights a response of cells to high-frequency stimuli which is more viscous than at low frequency, but also suggests a more complex response than expected.

Page generated in 0.0896 seconds