1 |
Kvalitetssäkring vid arbete med fukt i virkeStrid, Douglas, Ölmeby, Andreas January 2009 (has links)
<p>There are many factors in a building project that has to collaborate with one another in order to reach the desired end result, how you work with moisture issues in timber is a very important one. While constructing Varbergs Hospital, the building company Skanska came in contact with the issue of extra high demands on the moisture content in timber. What they requested from us was a moisture program in which you clearly could follow the routines regarding work with moisture in timber. The aim is to use this program as a help during the work, in order to achieve a good result.</p><p>We have developed this study in addition to the moisture program. The aim is that this study will give you a deeper understanding of the important factors to consider. In order to understand why you should work with timber in a certain way to avoid future problems, you have to understand the characters of timber and how moisture will affect it. In this study we have established that the entire timber handling process is very important and there are many steps that you have to take into consideration. Working with moist related issues in a qualitative way will create additional effects by increasing the quality of the other parts in the building process.</p>
|
2 |
Kvalitetssäkring vid arbete med fukt i virkeStrid, Douglas, Ölmeby, Andreas January 2009 (has links)
There are many factors in a building project that has to collaborate with one another in order to reach the desired end result, how you work with moisture issues in timber is a very important one. While constructing Varbergs Hospital, the building company Skanska came in contact with the issue of extra high demands on the moisture content in timber. What they requested from us was a moisture program in which you clearly could follow the routines regarding work with moisture in timber. The aim is to use this program as a help during the work, in order to achieve a good result. We have developed this study in addition to the moisture program. The aim is that this study will give you a deeper understanding of the important factors to consider. In order to understand why you should work with timber in a certain way to avoid future problems, you have to understand the characters of timber and how moisture will affect it. In this study we have established that the entire timber handling process is very important and there are many steps that you have to take into consideration. Working with moist related issues in a qualitative way will create additional effects by increasing the quality of the other parts in the building process.
|
3 |
Momentbelastade stål-till-KLträanslutningar för utomhusmiljöer / Moment-loaded steel-to-cross-laminated timber (CLT)connections for outdoor applicationsAkbari, Shafiqa, Mohseni, Zara January 2024 (has links)
Rapid climate changes have increased the importance of environmental concerns,particularly within the construction industry, which faces substantial challenges to reduceits environmental footprint. Shifting from high-emission building materials to sustainablealternatives stands as a critical strategy to reduce climate impact. Previous studiesdemonstrate that timber structures produced lower greenhouse gas emissions compared tonon-timber options like concrete and steel. CLT and its connections face a shortage of broad understanding and specific guidelines,notably in protected outdoor usage. Ambiguities in structural standards result inuncertainty, potentially leading to suboptimal outcomes and needless expenses. Toaddress these challenges, this study aims to bridge knowledge gaps by investigating steelto-CLT connections under cyclic moment loading and analyzing moisture content inoutdoor applications to determine appropriate climate classifications. Two experimentswere carried out: one indoors, evaluating cyclic moment loading's effects on steel-to-CLTconnections, and another outdoors, focusing on moisture development in CLT regardingsurroundings temperature and humidity. Results indicate noticeable stiffness variation due to cyclic loading, relaxationphenomena, and moisture content variations. This study offers valuable insights intounderstanding the structural behavior and moisture dynamics of steel-to-CLTconnections, which are critical for informed decision-making in the sustainable design ofsteel-to-CLT connections in protected outdoor applications.Keywords: moment loaded CLT connections, CLT connections, cyclic moment loading,moisture content, moisture content variation.
|
4 |
Fuktens påverkan på utegipsskivor under byggtidenSilfwerbrand, Erik, Sveder, Johan January 2006 (has links)
This thesis is a study of humidity at Knauf Danogips external plasterboard. The study is performed at the building project Kv. Maskinen in Jönköping in cooperation with NCC Construction AB and Knauf Danogips. The measuring was performed during five winter/spring months to see how the weather influenced the plasterboard. The measuring was performed at a small two-storied building and a larger fourstoried building. From the buildings` placement were a couple of measuring dots selected and to get a good result was the dots located in the four cardinal points. The dots were chosen equally on each level. To get a minimal influence on the plasterboard were the measuring performed with pin-meter which gives an exact result and is easy to use. The results were analyzed considered to RH, temperature and precipitation. The statistics came from the data base of SMHI. In regular circumstances the boards have a humidity of 8-13 % on delivery. But the humidity of the board rises during storage because they want to be balanced with the humidity of the surrounding air. Despite of the stabilization with the surrounding the humidity, in DUE 9, is low if the board is not exposed of snow, rain or liquefied snow. The results of the measuring at the small two-storied building and the larger four-storied building shows that the humidity is below the upper moisture limit for the plasterboard to be built into a wall construction. No visual damage was spotted on the boards and no connection between the humidity and the weather was observed. The study shows that Knauf Danogips strengthened external plasterboard DUE 9 manages the circumstances during the measuring period. It should be observed that the weather has been extremely good for the use of external plasterboards. According to Knauf Danogips should the plasterboard not be used in environments were RH exceed 85 % and our study shows that RH is almost exceeding 85 % during the whole period. But since RH depends on the temperature should it not be any problems to use the board during the winter. / Detta examensarbete är en studie av fuktkvotsmätningar gjorda på Knauf Danogips utvändiga gipsskiva DUE 9. Studien är utförd på byggprojektet Kv. Maskinen i Jönköping i samarbete med NCC Construction AB och Knauf Danogips. Under fem vinter- och vårmånader utfördes mätningar för att se hur väderleken påverkade gipsskivorna. Mätningarna utfördes på ett mindre tvåvåningshus (gårdshuset) och ett större fyravåningshus (huvudbyggnaden). Utifrån byggnadernas placering valdes ett antal mätpunkter placerade i de fyra olika väderstrecken för att nå ett heltäckande resultat. Punkterna valdes likadant på respektive våningsplan. För att få en minimal påverkan på gipsskivorna utfördes mätningarna med stiftmätare som ger ett noggrant resultat och är enkel att använda. Resultatet av mätningarna analyserades med hänsyn till relativa fuktigheten (RF), temperatur och nederbörd. Väderstatistiken kommer från SMHI:s databas. Vid normala omständigheter håller skivorna en fuktkvot på 8-13 % vid leverans. Men under förvaringen stiger skivornas fuktkvot eftersom skivorna eftersträvar fuktjämvikt med sin omgivning. Trots stabiliseringen med omgivningen håller DUE 9 en låg fuktkvot om den inte utsätts för direkt fukt i form av snö, regn eller smältvatten. Resultaten från mätvärden på gårdshuset och huvudbyggnaden visar att fuktkvoten ligger under det tillåtna gränsvärdet vid inbyggnad i en väggkonstruktion. Inga synliga skador på skivorna har upptäckts under mätperioden och inget samband kan ses mellan fuktkvoterna och väderparametrarna. Studien visar att Knauf Danogips förstärkta utegipsskiva DUE 9 klarar de förhållanden som rådit under mätperioden. Viktigt är då att påpeka att vädret har varit exemplariskt med hänsyn till användning av utvändig gips. Enligt Knauf Danogips ska produkten inte användas i miljöer där RF överstiger 85 % och vår studie visar att RF sällan understiger 85 % under mätperioden. Men eftersom RF är temperaturberoende bör det inte vara några problem att använda skivan under vintern.
|
5 |
Fuktens påverkan på utegipsskivor under byggtidenSilfwerbrand, Erik, Sveder, Johan January 2006 (has links)
<p>This thesis is a study of humidity at Knauf Danogips external plasterboard. The study is performed at the building project Kv. Maskinen in Jönköping in cooperation with NCC Construction AB and Knauf Danogips. The measuring was performed during five winter/spring months to see how the weather influenced the plasterboard.</p><p>The measuring was performed at a small two-storied building and a larger fourstoried building. From the buildings` placement were a couple of measuring dots selected and to get a good result was the dots located in the four cardinal points. The dots were chosen equally on each level. To get a minimal influence on the plasterboard were the measuring performed with pin-meter which gives an exact result and is easy to use. The results were analyzed considered to RH, temperature and precipitation. The statistics came from the data base of SMHI.</p><p>In regular circumstances the boards have a humidity of 8-13 % on delivery. But the humidity of the board rises during storage because they want to be balanced with the humidity of the surrounding air. Despite of the stabilization with the surrounding the humidity, in DUE 9, is low if the board is not exposed of snow, rain or liquefied snow. The results of the measuring at the small two-storied building and the larger four-storied building shows that the humidity is below the upper moisture limit for the plasterboard to be built into a wall construction. No visual damage was spotted on the boards and no connection between the humidity and the weather was observed.</p><p>The study shows that Knauf Danogips strengthened external plasterboard DUE 9 manages the circumstances during the measuring period. It should be observed that the weather has been extremely good for the use of external plasterboards. According to Knauf Danogips should the plasterboard not be used in environments were RH exceed 85 % and our study shows that RH is almost exceeding 85 % during the whole period. But since RH depends on the temperature should it not be any problems to use the board during the winter.</p> / <p>Detta examensarbete är en studie av fuktkvotsmätningar gjorda på Knauf Danogips utvändiga gipsskiva DUE 9. Studien är utförd på byggprojektet Kv. Maskinen i Jönköping i samarbete med NCC Construction AB och Knauf Danogips. Under fem vinter- och vårmånader utfördes mätningar för att se hur väderleken påverkade gipsskivorna.</p><p>Mätningarna utfördes på ett mindre tvåvåningshus (gårdshuset) och ett större fyravåningshus (huvudbyggnaden). Utifrån byggnadernas placering valdes ett antal mätpunkter placerade i de fyra olika väderstrecken för att nå ett heltäckande resultat. Punkterna valdes likadant på respektive våningsplan. För att få en minimal påverkan på gipsskivorna utfördes mätningarna med stiftmätare som ger ett noggrant resultat och är enkel att använda. Resultatet av mätningarna analyserades med hänsyn till relativa fuktigheten (RF), temperatur och nederbörd. Väderstatistiken kommer från SMHI:s databas.</p><p>Vid normala omständigheter håller skivorna en fuktkvot på 8-13 % vid leverans. Men under förvaringen stiger skivornas fuktkvot eftersom skivorna eftersträvar fuktjämvikt med sin omgivning. Trots stabiliseringen med omgivningen håller DUE 9 en låg fuktkvot om den inte utsätts för direkt fukt i form av snö, regn eller smältvatten. Resultaten från mätvärden på gårdshuset och huvudbyggnaden visar att fuktkvoten ligger under det tillåtna gränsvärdet vid inbyggnad i en väggkonstruktion. Inga synliga skador på skivorna har upptäckts under mätperioden och inget samband kan ses mellan fuktkvoterna och väderparametrarna.</p><p>Studien visar att Knauf Danogips förstärkta utegipsskiva DUE 9 klarar de förhållanden som rådit under mätperioden. Viktigt är då att påpeka att vädret har varit exemplariskt med hänsyn till användning av utvändig gips. Enligt Knauf Danogips ska produkten inte användas i miljöer där RF överstiger 85 % och vår studie visar att RF sällan understiger 85 % under mätperioden. Men eftersom RF är temperaturberoende bör det inte vara några problem att använda skivan under vintern.</p>
|
6 |
BYGGFUKT I BYGGNADER MED STOMME AV KORSLIMMAT TRÄ : Erfarenheter och mätresultat för tre byggnader uppförda med och utan väderskyddBano, Fadi, Michael, Steve, Youssef, Elefro January 2021 (has links)
Purpose: the purpose of this study is to examine the moisture ratio under that period with and without weather protection to see if it has an impact on the moisture levels. The purpose is also to identify the profitability of the weather protection and if there are other methods that can be used to replace it.Method: For this study different methods have been used to maintain the results. A literature study and a case study were made to achieve credible results and are the basis for this project. The case study is made on three different projects. One of the projects is a preschool with weather protection and is located in the city of Uppsala. The other two projects are without weather protection and one of them is located in Uppsala which is an apartment building and the other one in Stockholm and is a warehouse. Books, websites, scientific reports, and articles were used in the literature study to obtain important information to help the students to answer the questions.Results: The results show that the price for weather protection depends on which type of weather protection it is, how long time it will be used, and the size of it. Moisture measurements that were taken on the building projects without weather protection didn’t differ much from the project with. Results show there are many methods that can be used instead of weather protection to reduce high moisture levels. The wood pieces of the own experiment showed that after a couple of days they were dehydrated and the moisture ratios were below 15 %.Conclusions: Using weather protection depends on which project it is. It’s difficult to calculate the profit of weather protection during the construction stage. Weather protection has many benefits. The construction time will be decreased and you can install lights that can help the builders to see during the construction. The moisture ratio for the project with weather protection didn’t differ much from the projects without weather protection. According to the own experiment, wood is a very good material when it comes to dehydration of moisture.
|
7 |
Fuktproblem i uteluftsventilerade kallvindar / Moisture problems in outdoor air ventilated cold atticsLarsson, Anton, Rainio Reivilä, Johannes January 2017 (has links)
Detta examensarbete har genomförts med målet att undersöka om flerbostadshus som byggs enligt NCC:s tekniska plattform har kallvindar som är utsatta för eller riskerar att bli utsatta för fuktskador. En undersökning har gjort gällande hur det kommer sig att vissa konstruktioner klarar sig bättre än andra och vilka alternativa lösningar som finns på detta. Tio objekt valdes ut, alla konstruerade av NCC, alla med vindsbjälklag av betong, ventilerade med uteluft, med underlagstak av råspont och trätakstolar. De ligger alla i Stockholmsområdet och de är färdigställda mellan åren 2004 och 2016. För att göra dessa undersökningar, genomfördes mätningar på tio olika kallvindar. Relativ fuktighet och temperatur mättes med hjälp av klimatloggers som mätte inomhus och utomhus på varje objekt, en gång i timmen under mätperioden från den 13 februari till den 9 april. Fuktkvoten i trä mättes på alla kallvindar, där mätningar gjordes i råspont och takstol i varje väderstreck. Mätningarna gjordes vid tre tillfällen under perioden i varje kallvind. Under besöken genomfördes okulärbesiktningar på alla kallvindar där mögelpåväxt och konstruktionsdetaljer undersöktes. Historiskt sett är fuktproblem på kallvindar vanligt förekommande. Genom att kallvindar har ett välisolerat vindsbjälklag hålls temperaturerna allt som oftast låga i kallvindsutrymmet. Detta kan leda till att utrymmena får en hög relativ fuktighet och är därför utsatta för en ökad risk för fuktproblem. Genom nattutstrålning kan takytan få en lägre temperatur än kallvindsluften, vilket i sin tur kan leda till kondens på råsponten. Fuktkvoterna sjönk i snitt ungefär 4 procentenheter under mätperioden från 12% till 8%, vilket innebär att riskerna för röta eller mögelpåväxt är nästintill obefintlig, då riskerna för mögel och röta kräver fuktkvoter över 16% för att finnas. Den relativa fuktigheten ligger vid ett antal tillfällen över 75% i de olika kallvindarna, vilket är över BBR-kravet. Detta sker dock under perioder när temperaturerna är så låga att risker för fuktskador inte är aktuella. Under mätperioden har snittemperaturen gått upp, vilket har lett till att den relativa fuktigheten har minskat. Risken för mögelpåväxt har även bedömts med hjälp av diagram baserat på data från Smith och Hill samt Viitanen. Enligt dessa finns heller ingen risk för mögelpåväxt i någon av de tio kallvindarna. Enligt den okulära besiktningen kunde inga synliga fuktskador hittas i någon av de tio olika objekten. De fel som hittades var skillnader mellan objektens konstruktionsritningar och dess reella utförande. Objekt 3, 7 och 8 saknade ångspärr, vilket påstods finnas i ritningarna. Objekt 4 saknade luftning i nock som var utritad på ritningarna. Slutsatsen är att NCC:s konstruktioner för kallvindar på flerbostadshus är säkra gällande fuktskador. / This master thesis has been made with the goal to study if apartment buildings built according to NCC:s technical platform has ventilated cold attics exposed to risks for moisture damages. A study has been made to see how some types of constructions holds up better than others and how this can be solved. Ten objects were chosen, all constructed på NCC, all constructed with concrete joists, ventilated with outdoor air, a roof with underlay of tongue and groove and trusses of wood. They’re all situated in the Stockholm area and are completed between the years of 2004 and 2016. To complete these studies, measurements were made in ten different ventilated cold attics. Relative humidity and temperatures were measured with climate loggers, which collected data from both outdoors and indoors once every hour in the period from february 13 to april 9. The water content in wood was measured in all attics in the tongue and grove and the trusses, where measurements were made in all orientations of the attic. This data was collected at three times for each object. During the visits to the object, a visual inspection was made in all attics, where mold growth and construction details were inspected. Historically moisture problems are common in ventilated cold attics. When cold attics has a well insulated roof joist the temperatures is kept low in the attic. This may result in a high relative humidity and are therefore exposed to a higher risk of moisture problems. Due to night radiation the roof’s surface temperature could be lower than the air temperature in the attic, which can result in condensation on the tongue and grove. The water content in the wood decreased with an average of about 4 percentage points during the period of measurement from 12% to 8%, which means that the risks of mold growth and rot is nearly non-existent. To risk mold growth and rot, the water content has to be above 16%. The relative humidity is at a few occasions above 75% in the different attics, which is above the requirements from BBR. This, however, happens during periods when the temperature is at a level where the risk for moisture damage is very low. During the measurement period, the average temperatures has increased which resulted in a decreased relative humidity in the attics. The risk for mold growth has been evaluated in diagrams based on data from Smith and Hill and also Viitanen. According to these there are no risks of mold growth in any of the ten attics. According to the visual inspection no visible moisture damages could be found in any of the ten attics. The faults that were found was differences between the construction drawings and what was actually constructed. In the object 3, 7 and 8 there were no moisture barrier even though the drawings said so. In object 4 there were no ventilation in the ridge, which was to be found in the drawings. The conclusion is that there are no moisture problems in apartment buildings constructed by NCC.
|
8 |
En studie om fuktförhållanden i medeltida kyrka, Nättraby / A study on humidity conditions in medieval church, NättrabyBoman, Sandra January 2018 (has links)
Studien har genomförts i Nättraby kyrka efter ett förslag från Ankdammen konsult. Studien av Nättraby kyrka syftar till att ge ökad förståelse för hur fukt påverkar kyrkobyggnader. Under kartläggningen av kyrkans skick indikerades sprickor på inventarier, svarta fläckar på väggar, och mögel och rötangrepp i kryprummet. Författaren föreslår följande förbättringsåtgärder: Luft tätning runt dörrar och fönster, se över vattenledningssystemet, avlägsna organiskt material i krypgrunden, placera plastfolie intill grundmuren och på marken i krypgrunden samt installera adaptiv ventilation i krypgrunden.
|
9 |
Förhållandet mellan ultraljudshastigheten och fibervinkeln på stående hybridasp / Relationship between ultrasonic velocity and spiral grain in standing hybrid aspen treesSjöberg, Samuel January 2016 (has links)
Wood anisotropic- and orthotropic properties and structure, entails a certain limitation regarding its final use. Its properties have there an important role, depending on what it will be used. In order to not decompose the material for the full quality determination, necessary alternative methods that can do the job without decomposition. One such method is the acoustic investigation by ultrasonic techniques. The method has been used in a variety of areas, the last few decades, so even in the wood industry. One question asked was whether the method can be used to examine the slope of grain angle under bark of the hybrid aspen. A comparison of an acoustic ultrasonic measurements and a manual measurement with a fiber angle measuring device with respect to the fiber angle, were made. The result was that some connection existed between fiber angle and the ultrasonic velocity.
|
10 |
Virkesinvägning före torkning : Kan invägning av virkespaket optimera torkningsprocessen?Holmbom, Robin January 2017 (has links)
Virkestorkning är ett mycket energikrävande men nödvändigt förädlingssteg för träindustrin. Eftersom energi- och tidsåtgången framförallt är beroende av mängden fukt som ska drivas ur virket så är kännedom om virkets initiala och slutliga fuktinnehåll avgörande för en optimerad process. Industriellt, idag, görs ofta en grov uppskattning av virkets initiala fuktmängd. Denna fuktmängd ligger sedan till grund för torkningens genomförande och dess resultat. I föreliggande arbete undersöks huruvida invägning av virkespaketen före torkning kan användas för att bestämma virkets fuktinnehåll och hur detta kan bidra till att optimera torkprocessen. 17 fullständiga torkningsförsök genomfördes på ett konventionellt sågverk i norra Sverige. I försöken vägdes virkespaketen och torkningsscheman anpassades därefter.Genom mätningar av virkets fuktkvot och jämförelse med tidigare torkning där konventionella torkningsscheman använts så kunde det konstateras att paketvägningen bidrar till en förbättrad och optimerad torkningsprocess. / Drying is a very energy-intensive but important process in the wood industry. Since the amount of energy used is, more or less, proportional to the amount of water released, the measurement of the initial and final wood moisture content is crucial to optimize the process. Today, a rough estimate of the initial wood moisture content is used as dryer operation input data. The process could be improved by a more accurate determination of the initial moisture level. The present work examines if weighing the wood can be used as a method to determine the wood moisture level and how this can optimize the drying process. 17 drying trials were conducted at a sawmill in northern Sweden. The wood was weighed and new drying schedules were constructed and adjusted accordingly. The result show that weighing the wood results in more accurate drying schedules and overall an optimized drying process.
|
Page generated in 0.0389 seconds