• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 146
  • 3
  • Tagged with
  • 150
  • 150
  • 133
  • 85
  • 73
  • 69
  • 59
  • 55
  • 48
  • 48
  • 46
  • 45
  • 44
  • 39
  • 32
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Telemetria de resposta neural: repercussões dos fatores etiológicos e no reconhecimento de fala após o implante coclear / Neural response telemetry: repercussions of etiological factors and speech recognition after cochlear implant

Guedes, Mariana Cardoso 04 December 2007 (has links)
INTRODUÇÃO: O Potencial de Ação Composto Evocado Eletricamente(PACEE) é a medida da atividade sincrônica das fibras neurais eliciadas pelo implante coclear. O potencial é registrado diretamente da cóclea, utilizando os eletrodos como geradores do estímulo e gravadores da resposta, procedimento denominado Telemetria de Resposta Neural (TRN). A análise das características da resposta neural pode ser útil no conhecimento sobre a funcionalidade do nervo auditivo e das estruturas neurais sobreviventes. A presença do PACEE pode estar, portanto, relacionada ao resíduo auditivo e influenciar no desempenho para processar os estímulos de fala. OBJETIVO: Identificar os possíveis fatores associados à ausência do PACEE na condição intra-operatória e avaliar a repercussão da ausência de resposta neural no desempenho em testes de reconhecimento de fala após 06 meses de uso contínuo do implante coclear. MÉTODOS: Clínico longitudinal retrospectivo. Participaram do estudo todos os indivíduos operados entre 2003 e 2006 com o implante N24 e cujos exames evidenciaram inserção completa e ausência de alterações nas impedâncias (n = 97). A ausência da resposta neural foi estabelecida quando não se encontrava registro de onda com reprodutibilidade em nenhuma das séries de otimização em todos os eletrodos pesquisados. Os processadores de fala foram ativados com parâmetros sugeridos pelo fabricante e os níveis de corrente determinados pelo método psicoacústico. Os testes de percepção de fala foram realizados após seis meses de uso contínuo e sem leitura orofacial ou apoio de gestos. Os indivíduos foram divididos em grupos de acordo com a presença do PACEE: Grupo \"TRN presente\" e Grupo \"TRN ausente\". A média dos resultados nos testes de reconhecimento de fala foi comparada entre os dois grupos utilizandose o teste não paramétrico U de Mann-Whitney, Teste exato de Fisher e teste do Quiquadrado. RESULTADOS: No Grupo TNR ausente a prevalência de surdez por meningite foi de 48% e no Grupo TNR presente de 13.9% (p < 0,001). O risco relativo para um indivíduo com surdez pós-meningite não apresentar respostas neurais para o estímulo elétrico no intra-operatório é 3.1 vezes maior do que o de um indivíduo com surdez por outras causas. A amostra foi estratificada por etiologia. Os resultados mostraram forte associação entre a ausência do PACEE e piores resultados em testes de reconhecimento de fala. OS resultadoS dos indivíduos em que o potencial foi ausente foram significantemente menor que a média dos indivíduos com PACEE presente (p = 0,002), independente da etiologia da surdez. CONCLUSÃO: A ausência do PACEE em usuários do implante coclear sugere pobre capacidade de despolarização e de condução neural diante da estimulação elétrica. A etiologia de surdez por meningite esteve associada à ausência do potencial e à piores resultados nos testes de reconhecimento de fala. Independentemente deste fator, a presença do potencial no momento intra-operatório esteve associada ao melhor desempenho para processar estímulos de fala, sugerindo um bom prognóstico com o dispositivo. / INTRODUCTION: The Electrically Evoked Compound Action Potential (ECAP) is the register of synchronic activity o neural fibers stimulated by Cochlear Implant. The potential is registered directly from the cochlea using the electrodes as stimulus probe and recorder. This procedure is called Neural Response Telemetry (NRT). The analysis of ECAP can be useful to understand the auditory system function and the surviving neural population. The ECAP presence could be, though, related to auditory residual and influence the ability to process the speech stimulus. Objective: to identify the factors associated to the absent NRT responses and the consequence repercussions for speech recognition after six months of cochlear implant use. METHODS: longitudinal retrospective clinical study. Selection criteria: individual who received N24 cochlear implant model between 2003 and 2006 and presented exams showing complete insertion of electrode array and normal impedances results (n = 97). The NRT absent responses were established when there was no reproducible register in any optimization series of all electrodes searched. The implant speech processors were mapped according to the manufactures default. The current levels were determined by psychoacoustic method. The speech perception battery tests were performed after six months of continual use of device, without lipreading or gestures. The individuals were divided in two groups: Group \"NRT present\" and Group \"NRT absent\". The average of speech perception tests results were compared between groups using the non-parametric Mann-Whitney U test, Exact Fisher\'s test and Chi-square test. RESULTS: In NRT absent group the prevalence of post meningitis hearing loss was 48% and in NRT present group of 13.9% (p < 0.001). The results showed strong association between the absence of ECAP and lower performance in speech recognition sentence test. In these results, the average of subjects whose potential were absent was significantly lower than the ones with ECAP present by intraoperative NRT, regardless the hearing loss etiology (p = 0.002). CONCLUSION: The ECAP absence in cochlear implant users suggests poor neural conduction under electrical stimulus. The post meningitis hearing loss was associated to the absence of potential and poor performance in the speech recognition tests. However, the presence of reproducible ECAP waves was associated to a better performance in processing speech stimulus and suggests a good prognosis with the cochlear implant device.
22

Comunicação pré-linguística e aquisição de linguagem em crianças com implante coclear / Prelinguistic communication and language aquisition in children with cochlear implants

Antonio, Fernanda de Lourdes 21 March 2014 (has links)
Os programas de implante coclear têm recebido crianças com diagnóstico de deficiência auditiva sensorioneural ou com Desordem do Espectro da Neuropatia Auditiva ambos de grau severo e/ou profundo, que não se beneficiam com os aparelhos de amplificação sonora individuais, em idade precoce. Essas crianças são candidatas a realizar a cirurgia de implante coclear ainda nos primeiros anos de vida, período considerado sensível para a plasticidade neuronal. Nesta perspectiva, é um desafio para os profissionais da área determinar precocemente quais crianças podem obter os maiores benefícios com o implante coclear, pois devido a pouca idade, são muito sutis as respostas apresentadas e o comportamento comunicativo ainda incipiente. Este estudo teve como objetivo investigar a correlação entre os comportamentos de comunicação pré-linguística em crianças candidatas à cirurgia de implante coclear e a aquisição da linguagem falada subsequente ao uso do dispositivo. Participaram 11 crianças com deficiência auditiva sensorioneural severo e/ou profundo bilateral pré-lingual e duas crianças com Desordem do Espectro da Neuropatia Auditiva bilateral de grau severo e/ou profundo. O estudo de caráter longitudinal prospectivo avaliou os participantes da pesquisa em quatro tempos distintos, sendo o primeiro tempo no momento pré-cirúrgico e os demais tempos após a ativação do implante coclear, ao longo do primeiro ano de uso do dispositivo. Os dados foram coletados em entrevistas com os pais dos participantes da pesquisa, análise dos registros dos prontuários e avaliação da comunicação pré-linguística e de linguagem falada de cada criança. Foram utilizados os instrumentos: Denver Developmental Screening Test II DDST II, MacArthur - Bates Communicative Development Inventory (CDI) Parte II Ações e Gestos, Escala de Compreensão e Expressão Reynell Developmental Language Scales RDLS e a Escala de avaliação de desenvolvimento familiar. Os instrumentos utilizados para avaliar as habilidades comunicativas e de linguagem falada guardaram correlação positiva entre eles. O grupo estudado apresentou evolução no comportamento pré-linguístico e na aquisição da linguagem falada ao longo do uso do implante coclear. Houve correlação positiva entre a comunicação pré-linguística e a aquisição da linguagem falada das crianças participantes do estudo. / The cochlear implants programs have received early age children diagnosed with bilateral prelingual severe-to-profound sensorineural hearing loss or bilateral prelingual severe-to-profound Auditory Neuropathy Spectrum Disorder, who didnt benefit from hearing aids. These children are candidates for cochlear implant surgery still in the early years of life, period considered sensitive for neuronal plasticity In this perspective, it is a challenge for professionals is to determine precociously which children can get the greatest benefits with the cochlear implant, because due to their young age, the answers provided are very subtle and the communicative behavior still very incipient. The purpose of this study was to investigate the relationship between prelinguistic communication behaviors in implantation candidates and subsequent language development after cochlear implant use. The study included 11 bilateral prelingual severe-to-profound sensorineural hearing loss children and two children with bilateral prelingual severe-to-profound Auditory Neuropathy Spectrum Disorder. The prospective longitudinal study assessed the children in preimplantation period and during the first year of use after cochlear implant activation, totaling four assessments for each participant. Datas were collected through interviews with the participants parents, analysis of medical records and assessment evaluation of prelinguistic communication and spoken language of each child. Denver Developmental Screening Test II DDST II, MacArthur-Bates Communicative Development Inventory - CDI, Reynell Developmental Language Scales RDLS and Family Involvement Pating were used. There was a positive correlations between instruments used to assess the prelinguistic communication behaviors and spoken language. The group investigated showed an increase in prelinguistic behavior and the acquisition of spoken language throughout the cochlear implant use. There was a positive correlation between prelinguistic communication and the acquisition of spoken language of the participating children in the study.
23

Freqüência de uso do aparelho de amplificação sonora individual associado ao implante coclear nos pacientes adultos do HCFMUSP / The frequency of use of the hearing aid associated to the cochlear implant in adult patients of HCFMUSP

Yamaguchi, Cintia Tizue 30 September 2009 (has links)
OBJETIVO: Identificar a freqüência do uso de AASI contralateral ao implante coclear (IC), determinar as razões de alguns pacientes não usarem AASI contralateral e verificar o efeito do resíduo de audição na opção de uso do AASI contralateral ao IC. MÉTODOS: estudo observacional, transversal com 82 pacientes adultos submetidos a um questionário. RESULTADOS: Nesta amostra 70 não-usuários foram identificados. A prevalência de usuários foi de 12%, com IC 95% (11-13%). A maioria dos não usuários (58,2%) relataram ausência de benefício com AASI, enquanto que 23,6% relataram não ter sido orientada a utilização. Usuários tinham média tonal de 107 dBNA, contra 117 dBNA entre os não usuários. CONCLUSÃO: O uso de AASI contralateral é raro nesta amostra, devido à falta audição residual ou benefício com a amplificação / OBJECTIVE: To identify the frequency of the use of hearing aid contralateral to the cochlear implant; to determine the reasons why some patients do not use a contralateral hearing aid; to check the effect of residual hearing in contralateral hearing aid (CHA) users. METHODS: observational, transversal study with 82 adult patients who were submitted to a questionnaire. RESULTS: In this sample 70 non-users were identified. The prevalence of CHA users was 12% with 95% CI (11-13%). Most CHA non users (58.2%) reported lack of benefit with hearing aids, while 23,6% reported not being referred to the use. CHA users had pure tone average of 107 dB HL, versus the 117 dB HL among non users. CONCLUSION: The use of contralateral hearing aid is rare in this sample due to lack residual hearing or benefit with the amplification
24

Resolução temporal auditiva de crianças usuárias de implante coclear / Auditory temporal resolution in children using cochlear implantation

Comerlatto Junior, Ademir Antonio 15 July 2011 (has links)
A resolução temporal auditiva é considerada uma das habilidades mais importantes para o processamento do sinal acústico ao longo do tempo. Ela permite identificar diferenças finas dos aspectos segmentais da fala, como a identificação de fonemas, e o início e o final de palavras em frases encadeadas. Crianças usuárias de Implante Coclear (IC) apresentam características próprias de decodificação e processamento do sinal da fala ao longo do tempo, realizada pelo IC. Diante do exposto, esta pesquisa teve por objetivo verificar o desempenho de crianças usuárias de IC em tarefas de resolução temporal. A amostra foi composta por 20 crianças usuárias de IC Nucleus 24/SPRINT (Grupo Experimental - GE) e 20 crianças sem alterações auditivas (Grupo Controle - GC). Foram aplicados o Random Gap Detection Test (RGDT) e o teste Gaps In Noise (GIN) para avaliar a habilidade de resolução temporal por meio de tarefas de detecção de gap. Os testes foram aplicados em campo livre e a 40dBNS. Os testes estatísticos utilizados para a análise dos dados foram o teste t de Student para dados independentes, e o teste de Mann Whitney e o Coeficiente de Correlação de Pearson. As crianças usuárias de IC obtiveram limiares de gap no RGDT de 74,13±51 ms e no teste GIN de 12,12±2,53 ms, sendo que apenas quatro das 20 crianças realizaram o teste GIN. Os limiares de gap do GC foram de 18,77±12,29 ms no RGDT e de 6,13±1,27 ms no teste GIN. A diferença entre os dois grupos foi estatisticamente significante. Além disso, houve diferença significativa na comparação dos resultados dos testes entre os sexos do GE, sendo o masculino melhor que o feminino. Não houve correlação entre a idade e os limiares de detecção de gap em ambos os grupos e, também, não houve significância entre o tempo de uso de IC e os resultados nos testes no GE. Mesmo avaliando a mesma habilidade auditiva, não houve correlação significante entre os resultados dos testes aplicados. Foi observado que crianças usuárias de IC apresentam os limiares de detecção de gap significativamente maiores que crianças sem alterações auditivas. / Auditory temporal resolution is considered one of the most important skills for acoustic signal processing along the time. It allows the identification of fine differences of speech segmental aspects, such as phonemes and the beginning and end of words in linked phrases. Children using a cochlear implant (CI) present specific characteristics of speech sign decoding and processing, along the time, performed by the CI. Thus, this research aimed at verifying the performance of children fitted with CIs, in temporal resolution tasks. The sample comprised 20 children using CI Nucleus 24/SPRINT (Experimental group - EG) and 20 children with no auditory alterations (Control Group - CG). The Random Gap Detection (RGDT) and Gaps In Noise (GIN) tests were applied to assess the temporal resolution skill through gap detection tests which were applied in free field and 40 dBSL. The statistical tests utilized for data analysis were Student´s t test, for independent data, Mann Whitney´s test and Pearson´s Correlation Coefficient. The children fitted with CIs achieved gap thresholds of 74,13±51 ms on the RGDT and 12,12±2,53 ms on the GIN test, the latter performed by only four out of the 20 children. Gap thresholds for the CG were 18,77±12,29 ms on the RGDT and 6,13±1,27 ms on the GIN test. The difference between the two groups was statistically significant. There was a significant difference in the comparison of the results of tests between the genders of EG, with males outdoing females. No correlation was seen between age and gap detection thresholds for both groups and there was no significance between the time of CI use and the results on the tests for the EG. Even assessing the same hearing skill, no significant correlation was seen between the results of the tests applied. Thus, it was observed that children fitted with cochlear implantation present gap detection thresholds significantly worse than those presented by normally hearing children.
25

Verificação eletroacústica de sistemas de frequência modulada em usuários de implante coclear / Electroacoustic verification of frequency modulation systems in cochlear implant users

Fidêncio, Vanessa Luisa Destro 06 July 2017 (has links)
O objetivo deste estudo foi realizar e determinar a validade de um protocolo de teste de verificação eletroacústica para Sistemas de Frequência Modulada (FM) acoplados a diferentes processadores de fala de implantes cocleares. Participaram deste estudo 40 crianças, com idades entre 5 e 18 anos incompletos, usuários de quatro modelos diferentes de processadores de fala. A verificação eletroacústica foi realizada por meio do uso do equipamento Audioscan Verifit (VF-1) com acoplador HA-1, além do uso do dispositivo de verificação de escuta correspondente a cada modelo de processador de fala do implante coclear. Nos casos em que a transparência não foi atingida, foi realizada alteração no ajuste do ganho do Sistema FM e avaliação da percepção auditiva da fala no ruído por meio da aplicação da versão brasileira do teste Phrases in Noise Test (PINT). Houve transparência entre o Sistema FM e o implante coclear em 85% dos dispositivos avaliados. Após o ajuste do ganho FM nos outros casos, os dispositivos apresentaram-se transparentes quando o teste de verificação eletroacústica foi repetido. Também foi observado que os participantes submetidos ao teste de percepção de fala no ruído apresentaram melhor desempenho após o novo ajuste, de modo que, nestes casos, a transparência eletroacústica ocasionou em transparência comportamental. Concluiuse que o protocolo de verificação eletroacústica utilizado mostrou-se efetivo para a avaliação da transparência entre o Sistema FM e o implante coclear. A realização prévia do ajuste do processador de fala e do ganho do Sistema FM mostrou-se essencial para que a transparência fosse atingida. / The purpose of this study was perform and determine the validity of an electroacoustic verification test for FM Systems coupled to different cochlear implant speech processors. The sample included 40 participants between 5-18 years users of four different models of speech processors. For the electroacoustic evaluation, we used the Audioscan Verifit device with the HA-1 coupler and the listening check devices corresponding to each speech processor model. In cases where the transparency was not achieved, was made a modification in the FM gain adjustment and used the Brazilian version of the \"Phrases in Noise Test\" (PINT) to evaluate the speech perception in competitive noise. It was observed that there was transparency between the FM System and the cochlear implant in 85% of the participants evaluated. After adjusting the gain of the FM receiver in the other participants, the devices showed transparency when the electroacoustic verification test was repeated. It was also observed that they presented better performance in speech perception in noise after a new adjustment, that is, in these cases, the electroacoustic transparency caused behavioral transparency. It was concluded that the electroacoustic evaluation protocol suggested was effective to evaluate transparency between the FM System and the cochlear implant. Performing the adjustment of the speech processor and the FM System gain are essential when fitting this device.
26

Percepção de fala em adolescentes com surdez pré-lingual usuários de implante coclear / Speech perception in adolescents with pre-lingual hearing impairment with cochlear implants

Souza, Izi Patrícia Souza de 03 October 2012 (has links)
INTRODUÇÃO: A surdez profunda é uma deficiência que afeta a personalidade, o relacionamento e todo o estilo de vida do paciente e quando se trata de adolescentes com surdez profunda pré-lingual, esses conflitos biopsicossociais são exacerbados, necessitando de cautela na avaliação e escolha destes candidatos ao implante coclear. OBJETIVO: Avaliar a percepção de fala em adolescentes portadores de surdez pré-lingual do tipo neurossensorial severa a profunda bilateral com implante coclear. FORMA DE ESTUDO: Prospectivo. CASUÍSTICA E MÉTODO: O estudo foi desenvolvido no Ambulatório de Implante Coclear do grupo de Otologia do Hospital das Clinicas da Faculdade de Medicina da USP. 25 indivíduos com surdez pré-lingual, sensório-neural, de grau severo ou profundo, que foram submetidos ao implante coclear na adolescência, definida entre 10 a 17 anos e 11 meses, passaram por testes de percepção de fala pré-implante coclear e 2 anos após a ativação do dispositivo. Para a comparação e análise utilizamos os resultados dos testes de four choice, reconhecimento de vogais e reconhecimento de sentenças em conjunto fechado e aberto. RESULTADOS: Devido a assimetria na distribuição dos dados, os mesmos estão sumarizados como mediana e intervalo interquartis (percentil 25 percentil 75). Houve variação estatisticamente significante entre as avaliações pré e pós- implante para todos os testes analisados. CONCLUSÃO: Todos os pacientes, embora com resultados heterogêneos, obtiveram melhora estatística em todos os testes de fala que foram aplicados / INTRODUCTION: The profound deafness is a disability that affects personality, relationships and lifestyle of the patient and when it comes to teenagers with profound hearing loss before language, these conflicts are exacerbated biopsychosocial, requiring careful evaluation and choice of candidates implant. OBJECTIVE: To evaluate speech perception in Cochlear Implants for adolescents with severe to profound prelinguistic deafness. STUDY DESIGN: Prospective. MATERIAL AND MÉTHOD: The study was conducted at the Ambulatório de Implante Coclear do grupo de Otologia do Hospital das Clinicas da Faculdade de Medicina da USP. 25 individuals with severe or profound prelinguistic deafness who underwent cochlear implantation in adolescence, set between 10 to 17 years and 11 months, passed tests of speech perception pre-implant and 2 years after activation of the device. For comparison and analysis were used the results of tests of four choice, recognition of vowels and recognition of sentences in closed set and open set. RESULTS: Because of asymmetry in the distribution of data, they are summarized as median and interquartile range (25th percentile - 75th percentile). The results have very significant differences between pre-and post-implant for all tests analyzed. CONCLUSION: All patients, although with mixed results, achieved statistical improvement in all speech tests that were applied
27

Percepção da fala em crianças usuárias de implante coclear com duas estratégias de processamento do sinal do sistema HiResolution / Speech perception in children with cochlear implants with two sound processing strategy of the HiResolution system

Melo, Tatiana Mendes de 22 October 2012 (has links)
A melhora na percepção da fala dos usuários de implante coclear (IC) ao longo do tempo está relacionada, entre outros fatores, ao avanço tecnológico das estratégias de processamento do sinal. Deste modo, o objetivo deste trabalho foi avaliar o desempenho de percepção da fala em crianças usuárias de IC, utilizando duas diferentes estratégias de processamento do sinal do sistema HiResolution da Advanced Bionics. Para tanto, participaram deste estudo 11 crianças com deficiência auditiva pré-lingual, usuárias do componente interno HiRes 90K e processador de fala modelo platinum, e que apresentavam habilidade auditiva de reconhecimento em conjunto aberto. Foi realizada a avaliação intra-sujeito em três momentos, de acordo com a estratégia de fala utilizada. O desempenho da linha de base foi avaliado com a estratégia HiResolution 120 (HiRes 120) e posteriormente, foi realizada a conversão da estratégia para a HiResolution (HiRes). Após três meses de uso da estratégia HiRes, os participantes foram avaliados e realizada a conversão da estratégia para a HiRes 120. Após três meses de uso da HiRes 120, os participantes foram reavaliados. Em todas as avaliações, os participantes foram submetidos à pesquisa dos limiares audiométricos em campo livre, avaliação da percepção da fala por meio do teste Hearing in Noise (HINT), no silêncio e na presença de ruído competitivo e, avaliação dos benefícios proporcionados pelo uso do IC em situações cotidianas, por meio do questionário Parents\' Evaluation of Aural/oral Performance of Children (PEACH). Os resultados demonstraram que não houve diferença dos limiares audiométricos em campo livre, do desempenho auditivo no silêncio e do benefício do IC em situações de vida diária, em função da estratégia de processamento de sinal utilizada. Houve tendência de melhor desempenho auditivo na situação de ruído com o uso da estratégia de processamento de sinal HiRes 120, embora, tal resultado não tenha sido estatisticamente significante. Essa tendência indica que a representação espectral do sinal acústico de forma mais detalhada proporcionada pela HiRes 120 pode auxiliar no desempenho auditivo de crianças usuárias de IC em situações de ruído, contudo, essa característica da estratégia de processamento de sinal não influenciou o desempenho auditivo nas situações de silêncio. Reforça-se a importância da observação clínica e avaliação de percepção de fala com ruído na seleção da estratégia de processamento de sinal, a fim de otimizar o desempenho auditivo dos usuários de IC. / Improvements in speech perception with cochlear implant (CI) over the years is related, among others factors, to the technological advance of the sound processing strategy. The purpose of the present study was to investigate speech perception performance in CI children, with two different Advanced Bionics sound processing strategy. Subjects were 11 prelingually deafened children implanted with the HiRes 90K cochlear implant and used a bodyworn platinum sound processor. All subjects showed evidence of open-set speech recognition. A within-subjects design was used to compare performance with standard HiRes and HiRes 120. Baseline performance was assessed with HiResolution 120 (HiRes 120). Subjects then were fitted with HiResolution (HiRes) and returned for re-evaluation after three months of use. After three months of HiRes experience, subjects were refitted with HiRes 120 and returned three months later for reassessment. During test sessions, subject\'s performance was evaluated by warble-tone sound-field thresholds, the Brazilian Hearing in Noise test (HINT) in quiet and in noise and Parents\' Evaluation of Aural/oral Performance of Children questionnaire (PEACH). The detection thresholds, the speech perception in quiet and the CI benefit in daily life were similar for both sound processing strategy. There was a trend toward better hearing performance in noise with HiRes 120, although this result was not statistically significant. This trend indicates that more precise spectral representation of the acoustic signal provided by the HiRes 120 can result in an improvement in the speech perception in noise by CI children. However, this characteristic did not influence the auditory performance in quiet. It reinforces the importance of clinical observation and speech perception in noise assessment in the sound processing strategy selection, in order to optimize the auditory performance of CI users.
28

Avaliação da percepção da fala com ruído competitivo em crianças portadoras de deficiência auditiva neurossensorial com espectro da neuropatia auditiva usuárias de implante coclear / Assessment of speech perception with competitive noise in children with sensorineural hearing loss with auditory neuropathy spectrum disorder and cochlear implants users

Yamaguti, Elisabete Honda 28 February 2013 (has links)
Nos últimos anos houve um grande avanço na tecnologia de processamento de sinal do Implante Coclear (IC), mas ainda há uma limitação a ser superada que é a percepção de fala no ruído. Este dispositivo passou a ser indicado para habilitação e reabilitação de um grupo com características audiológicas e eletrofisiológica específica, denominada de Desordem do Espectro da Neuropatia Auditiva (DENA). As características inerentes a este tipo de alteração auditiva podem determinar dificuldades adicionais para o desenvolvimento de habilidades auditivas mais complexas, tal como a percepção dos sons da fala na presença de ruído. Deste modo, este estudo tem como objetivo investigar a percepção de fala na presença de ruído em crianças portadoras de deficiência auditiva neurossensorial com DENA e usuárias de IC e comparar com um grupo de crianças portadoras de deficiência auditiva sensorial usuárias de IC. Trata-se de um estudo realizado no Centro de Pesquisas Audiológicas (CPA) do Hospital de Anomalias Craniofaciais da Universidade de São Paulo na cidade de Bauru (HRAC/ USP). Para a realização da avaliação da percepção de fala no ruído foi utilizado o Teste HINT / BRASIL (Hearing in Noise Test versão em português do Brasil), proposto por NILSSON et al. (1994) e adaptado para a língua portuguesa por BEVILACQUA et al. (2008). A amostra inicial foi formada por 48 crianças com DENA, após os critérios de inclusão 14 crianças com DENA fizeram para do grupo experimental e 12 crianças com deficiência auditiva neurossensorial do grupo controle. Não foram observados resultados estatisticamente significantes para os dois grupos com relação aos testes de percepção de fala no ruído, com relação às habilidades auditivas e de linguagem foi possível observar evolução das habilidades com o tempo de uso para os dois grupos. Pode-se concluir que o IC é indicado para o tratamento das crianças com DENA e estas se comportam de modo bem similar às crianças com deficiência auditiva neurossensorial. / In recent years, there has been a major breakthrough in signal processing technology of cochlear implant (CI), but there is a limitation to be overcome, which is the perception of speech in noise. This device is now indicated for habilitation and rehabilitation of a group with specific electrophysiological and audiological features, called Auditory Neuropathy Spectrum Disorder (ANSD). The characteristics inherent to this type of hearing impairment may determine additional difficulties for developing more complex listening skills, such as the perception of speech sounds in noise. Thus, this study aims to investigate the speech perception in noise in children with sensorineural hearing loss with ANSD and users of CI, and compare with a group of children with sensorineural hearing loss CI users. It is a study in Centro de Pesquisas Audiológicas (CPA), at the Hospital de Anomalias Craniofaciais da Universidade de São Paulo - Bauru (HRAC/ USP). To perform the evaluation of the speech perception in noise test was used HINT / BRAZIL (Hearing in Noise Test - Portuguese version of Brazil), proposed by Nilsson et al. (1994) and adapted into Portuguese by BEVILACQUA et al. (2008). The initial sample was formed consisting of 48 children with ANSD, after the inclusion criteria, 14 children with ANSD made for the experimental group and 12 children with sensorineural hearing loss in the control group. There was no statistically significant results for the two groups with respect to test speech perception in noise, compared with auditory and language skills was possible to observe the evolution of skills with time of use for both groups. It can be concluded that the CI is indicated for the treatment of children with ANSD, and they behave very similarly to children with sensorineural hearing loss.
29

Qualidade de vida de crianças com implante coclear / Quality of life of children with cochlear implants

Silva, Joice de Moura 07 February 2018 (has links)
Diversos fatores influenciam sobre o desempenho das habilidades auditivas, da linguagem falada e da qualidade de vida de crianças com implante coclear. Investigar o impacto multidimensional da deficiência auditiva nas várias demandas da vida da criança pode auxiliar na identificação das variáveis de maior influência sobre os resultados desta população. O alcance dos maiores benefícios proporcionados pelo uso do dispositivo eletrônico depende da inserção efetiva na terapia fonoaudiológica especializada e dos investimentos na participação da família no processo de habilitação e reabilitação auditivas. Este estudo teve como objetivo avaliar a qualidade de vida de crianças com deficiência auditiva pré-lingual usuárias de implante coclear e analisar a correlação com os resultados da percepção auditiva da fala, com o desempenho da linguagem falada e com o grau de permeabilidade familiar no processo terapêutico. Participaram da pesquisa 30 crianças de ambos os sexos, com idade entre seis anos completos a 12 anos incompletos, usuárias de implante coclear e seus respectivos pais e/ou responsáveis legais. As crianças foram avaliadas quanto à percepção auditiva da fala, o desempenho da linguagem falada, a permeabilidade familiar e a qualidade de vida. A avaliação das habilidades auditivas mostrou correlação estatisticamente significante entre a escala de audição Categories Auditory Performance (CAP) e a Categoria de Linguagem. Na avaliação da linguagem falada não foram observados resultados estatisticamente significantes entre as variáveis do estudo. A permeabilidade familiar revelou correlações estatisticamente significantes com a CAP. Na perspectiva dos pais o IC melhorou a qualidade de vida em todos os domínios relacionados à criança e em um dos domínios referente à família. A subescala relações sociais apresentou maior escore entre os domínios. O aumento da idade cronológica impactou positivamente sobre os aspectos educacionais da qualidade de vida. Crianças com maiores categorias de audição apresentaram influência sobre a comunicação e a educação, a comunicação foi influenciada também pela categoria de linguagem. As habilidades de linguagem se correlacionaram com a autonomia das crianças e os pais mais permeáveis à reabilitação impactaram sobre a comunicação e a educação. Não foram encontradas correlações estatisticamente significantes entre a qualidade de vida e a idade na cirurgia e a idade auditiva. No entanto, a correlação negativa entre a idade na cirurgia e a qualidade de vida sugere que crianças implantadas mais cedo tendem a ter melhor qualidade de vida. Concluiuse, portanto, que a variável linguagem oral influenciou a qualidade de vida nos domínios comunicação e autonomia da criança. As variáveis desempenho auditivo e permeabilidade familiar influenciaram a qualidade de vida nos domínios comunicação e educação. A qualidade de vida no domínio educação também foi influenciada pela idade cronológica da criança. / Several factors have influence on the performance of hearing abilities, spoken language and quality of life of children with cochlear implants (CI). Investigating the multidimensional impact of hearing impairment on the various demands of the child\'s life can help identifying the variables that most influence on results of this population. The achievement of the greatest benefits provided by the use of the electronic device depends on effective insertion in specialized speech therapy and investments in family participation in the auditory habilitation and rehabilitation process. This study aimed to evaluate the quality of life of children with prelingual hearing loss who use cochlear implants and to analyze the correlation with the results of auditory perception of speech, the performance of spoken language and the degree of family permeability in the therapeutic process. Thirty children of both sexes, ranging from six complete years to 12 incomplete years, who use cochlear implants and their respective parents and/or legal guardians participated in the study. The children were evaluated for auditory perception of speech, performance of spoken language, familial permeability and quality of life. The evaluation of hearing abilities showed a statistically significant correlation between the auditory scale Categories Auditory Performance (CAP) and Language Category. In the evaluation of spoken language, no statistically significant results were observed among the studied variables. Familial permeability revealed statistically significant correlations with CAP. From the perspective of parents, CI improved quality of life in all domains related to the child and in one of the domains related to the family. The subscale social relations presented a higher score among the domains. The increase of chronological age had a positive impact on the educational aspects of quality of life. Children with higher hearing categories had an influence on communication and education, and communication was also influenced by language category. Language skills were correlated with the autonomy of children, and parents more permeable to rehabilitation impacted on communication and education. No statistically significant correlations were found between quality of life and age at surgery and hearing age. However, the negative correlation between age at surgery and quality of life suggests that early implanted children tend to have a better quality of life. Therefore, it was concluded that the variable oral language influenced the quality of life in the domains communication and autonomy of the child. The variables auditory performance and familial permeability influenced on quality of life in communication and education domains. Quality of life in the education domain was also influenced by the chronological age of the child.
30

Linguagem oral em crianças com cinco anos de uso do implante coclear / Oral language of children with five years of experience using coclear implant

Stuchi, Raquel Franco 07 April 2009 (has links)
INTRODUÇÃO. A linguagem oral é a forma mais efetiva de comunicação em nossa sociedade. A audição é fundamental para o desenvolvimento da linguagem oral. A partir da década de 90 o implante coclear (IC), apesar de não substituir a função coclear, vêm trazendo resultados expressivamente benéficos para o desenvolvimento da linguagem oral de crianças deficientes auditivas sensórioneural severa/profunda pré-lingual. Os estudos atuais têm se preocupado em identificar os fatores que levam algumas crianças com deficiência pré-lingual usuárias de IC a alcançar um desempenho de linguagem oral melhor do que as outras. Entre outros fatores, sabe-se que quanto antes a criança recebe o implante e conforme vai aumentando o tempo de uso do implante o desempenho melhora.Poucos estudos se voltam para a caracterização da linguagem oral dessas crianças. Objetivos: 1. Avaliar a linguagem oral, tanto a compreensão quanto a expressão, das crianças usuárias de IC há 5 anos; 2. Avaliar a relação entre o desempenho de compreensão oral com o desempenho de expressão oral das crianças usuárias de IC há 5 anos; 3. Avaliar a relação entre o desempenho de linguagem oral e o índice reconhecimento de fala dessas crianças; Método: 27 crianças deficientes auditivas pré-linguais usuárias de IC com tempo de uso do IC variando de 5a a 5a11m foram avaliadas por meio da Reynell Developmental Scales II (RDLS) composta pela Escala de Compreensão (C) e Escala de Expressão (E). Foi realizada a análise quantitativa descritiva das pontuações nas seções de C e E. Foi realizada calculado o coeficiente de correlação de Pearson entre as medianas das pontuações totais na Escala de Compreensão e de Expressão de cada indivíduo. Foi calculado o coeficiente de correlação de Spearman entre a pontuação na C e índice de reconhecimento de fonemas; pontuação na E e índice de reconhecimento de fonemas; pontuação RDLS total e índice de reconhecimento de fonemas. RESULTADOS: As medianas das pontuações indicaram que tanto em C como em E houve maior dificuldade em relação às sentenças com maior extensão, palavras de sentido gramatical, palavras e sentenças mais independentes do contexto imediato e mais facilidade em relação à palavras de sentido lexical e mais dependentes do conexto; houve correlação positiva e estatisticamente significante entre C e E. Houve relação estatisticamente significante entre o índice de reconhecimento de fonemas de C, E e pontuação total da RDLS. CONCLUSÕES:Apesar da variabilidade encontrada, as crianças implantadas há cinco anos apresentam dificuldade em relação ás palavras de sentido gramatical e frases com maiores extensões, bem como palavras e frases que não dependem do contexto imediato. A linguagem oral das crianças implantadas há cinco anos está aquém da esperada para a idade cronológica das mesmas. Não houve discrepância entre compreensão e expressão, entretanto mais estudos são necessários para que se determine a superioridade de uma ou de outra. A correlação entre o índice de reconhecimento de fonemas e o desempenho de linguagem comprova a importância da audição para a linguagem oral / INTRODUCTION. The oral language is the most effective form of communication in our society. Hearing is the primary method for the oral language development. Even though the Cochlear Implant (CI) does not replace the Cochlear Function, since the 90´s it has bringing results that are significant beneficial to the oral language development of children with prelingual severe to profound hearing loss. Current researches have been concerned identifying the factors that make some children users of IC with pre-lingual hearing loss to achieve better oral language performance than the others. Besides that, it is known that if the child is implanted soon and the time of use increases, the performance will improve. Few studies turn to the characterization of these children oral language, which is a deviant process in relation to normality, but still needs more research. OBJECTIVES: 1. Evaluate both the comprehensive and expressive language of children that have been Cochlear Implanted for 5 years. 2. Assess the relationship between the comprehensive and expressive language performances of this population. 3. Assess the relationship between the oral language performance and their speech perception. METHOD: 27 children with pre lingual hearing loss that have been implanted for 5 to 5 years and 11 months were evaluated by the Reynell Developmental Scales II ( RDLS) composed by the Comprehensive Scale (C) and Expression Scale (E). The quantitative description of the scores in the sections C and E was performed and the Pearson correlation coefficient between the median scores in the total scale of comprehension and expression of each individual was calculated. In addition, the Spearman correlation coefficient between the score in the C index and phonemes recognition, the score on section E and the score for phonemes recognition, RDLS total score index and phonemes recognition were also calculated. RESULTS: The median scores demonstrated that both on C and E there were greater difficulty with longer sentences, the grammatical meaning of words, words and sentences that were more independent of immediate context. The lexical meaning of words with more context were more straightforward. There were a positive statistically correlation between C and E. There was a significant statistically relationship between the rate of phonemes recognition of C, E and the total score of RDLS. CONCLUSIONS: Despite the established variability, the children that were implanted five years ago have found difficulties with the grammatical meaning of words, longer phrases, and words and phrases that do not depend on the immediate context. The oral language of children implanted five years ago is inferior if compared with children with the same chronological age. There was similarity between expression and comprehension, however, more studies are required to determine whether the superiority of one or other. The correlation between the speech perception and the language performance demonstrates the importance of hearing for oral language development

Page generated in 0.0682 seconds