• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 417
  • 7
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 428
  • 258
  • 235
  • 129
  • 125
  • 98
  • 84
  • 83
  • 80
  • 78
  • 64
  • 51
  • 49
  • 45
  • 43
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
201

"Desenvolvimento de instrumentação e procedimentos analíticos automáticos para a determinação espectrofotométrica de tensoativos em águas" / "Development of the instrumentation and automatic analytical procedures for spectrophotometric determination of surfactants in waters"

André Fernando Lavorante 23 February 2006 (has links)
"Neste trabalho, propõe-se o desenvolvimento de instrumentação e procedimentos analíticos automáticos para a determinação de tensoativos em águas empregando o conceito de multicomutação em fluxo. Visando a miniaturização do sistema, a minimização do consumo de reagentes, e da geração de efluentes foram utilizadas mini-bombas solenóide para a propulsão dos fluidos e válvulas solenóide de estrangulamento para controlar a manipulação das soluções. Estes dispositivos foram controlados por um microcomputador equipado com uma interface eletrônica baseada no circuito integrado ULN2803A a qual foi acoplada à saída da impressora. Como sistema de detecção foram empregados um espectrofotômetro HP8452A, um espectrofotômetro multicanal com arranjo linear de fotodetectores do tipo CCD e um fotômetro baseado em dois LEDs (azul e vermelho) como fonte de radiação e um fotodiodo de silício (IPL10530DAL) como detector. A aquisição dos dados do fotômetro foi realizada com um multímetro digital com saída serial RS232, empregando um programa escrito em linguagem VISUAL BASIC 3.0. No mesmo programa foram incluídas rotinas para controle do módulo de análise. Primeiramente, foram desenvolvidos a instrumentação e os procedimentos analíticos para a determinação independente de tensoativos aniônicos e catiônicos em águas. O mesmo módulo de análises foi utilizado para os dois tensoativos e foi constituído de quatro mini-bombas solenóide. O procedimento proposto para a determinação de tensoativos aniônicos foi baseado na substituição do reagente cromogênico alaranjado de metila (MO) pelo tensoativo aniônico dodecilbenzeno sulfonato de sódio (DBS), formando o par-iônico com o tensoativo catiônico cloreto de cetilpiridino (CPC) em pH 5,0. A instrumentação proposta possibilitou a obtenção de resposta linear entre 1,4 x 10-6 mol L-1 e 1,4 x 10-5 mol L-1 (0,5 - 5 mg L-1) (R = 0,997, n = 7), limite de detecção de 9,8 x 10-8 mol L-1 (0,034 mg L-1), e freqüência de amostragem de 60 determinações por hora. O desvio padrão relativo foi estimado em 0,8 % (n = 11) usando uma solução de referência contendo 5,7 x 10-6 mol L-1 (2 mg L-1) de DBS. Os resultados obtidos pelo método proposto processando amostras de efluentes domésticos e industriais foram comparados com os obtidos empregando-se o método de referência, e não foi observada diferença significativa em nível de confiança de 95 %. Para a determinação de tensoativos catiônicos em águas foi desenvolvido um procedimento baseado na formação do complexo ternário entre tensoativo catiônico CPC, Fe (III) e cromazurol S (CAS) em pH 4,5. Com o sistema proposto, utilizando-se uma cela de detecção de 40 mm de comprimento, obteve-se resposta linear entre 0,1 x 10-5 mol L-1 e 3,0 x 10-5 mol L-1 (0,34 - 10,2 mg L-1) (R = 0,999, n = 9), limite de detecção estimado em 1,0 x 10-7 mol L-1 (0,035 mg L-1), desvio padrão relativo de 0,6 % (n = 11) empregando uma solução de referência contendo 1,0 x 10-5 mol L-1 (3,4 mg L-1) de CPC, e freqüência de amostragem de 72 determinações por hora. O procedimento foi aplicado em amostras de águas coletadas no rio Piracicaba. Empregando-se teste de adição e recuperação foi observada recuperação entre 91 % e 106 %. O módulo de análise para a determinação seqüencial de tensoativos aniônicos e catiônicos foi constituído de duas mini-bombas solenóide e seis válvulas solenóide de estrangulamento. Com o sistema proposto, as características analíticas para os tensoativos aniônicos foram: resposta linear entre 0,1 x 10-5 mol L-1 e 3,0 x 10-5 mol L-1 (0,35 - 10,5 mg L-1) (R = 0,9992, n = 7); limite de detecção estimado em 1,6 x 10-7 mol L-1 (0,056 mg L-1); desvio padrão relativo de 0,6 % (n = 11) usando uma solução de referência contendo 1,0 x 10-5 mol L-1 (3,5 mg L-1) de DBS. Para os tensoativos catiônicos obteve-se resposta linear entre 0,1 x 10-5 mol L-1 e 3,0 x 10?5 mol L-1 (0,34 - 10,2 mg L-1) (R = 0,9992, n = 7); limite de detecção estimado em 1,4 x 10-7 mol L-1 (0,05 mg L-1); desvio padrão relativo de 0,5 % (n = 11) usando uma solução de referência contendo 1,0 x 10-5 mol L-1 (3,4 mg L-1) de CPC. O consumo das soluções de reagentes e de amostra foram de 400 mL e 200 mL, respectivamente, e freqüência de amostragem de 60 determinações por hora, para ambos tensoativos. O sistema foi aplicado em amostras de águas coletadas no rio Corumbataí, e os resultados obtidos com testes de adição e recuperação variaram entre 91 % e 105 %. Aplicando-se teste-t entre os resultados obtidos pelo procedimento proposto e pelos métodos de referência (aniônicos) e de validação (catiônicos), os resultados foram concordantes em nível de 95 % de confiança." / "In this work, development of the instrumentation and automatic analytical procedures for spectrophotometric determination of surfactants in waters employing the multicommutation concept were proposed. Aiming to system miniaturization, reduction of reagents consumption and effluents generation, solenoids micro-pump and solenoids pinch valves were used for the fluids propulsion and for solutions management, respectively. These devices were controlled by a microcomputer equipped with an electronic interface based on the integrate circuit ULN2803A that was coupled to the printer output. As system detection was employed an spectrophotometer model HP8452A, a multichannel spectrophotometer with CCD array linear arrangement of photodetectors and a homemade LED based photometer comprising two LEDs (blue and red) as radiation source and a photodiode (IPL10530DAL) as detector. In this case, the data acquisition was accomplished with a digital multimeter with serial out put RS232 employing a software wrote in VISUAL BASIC 3.0. The software comprised also routines to control the analysis module. Firstly, instrumentation and analytical procedures for independent determination of anionic and cationic surfactants in waters were developed. The same flow system comprised of four solenoid micro-pumps and it was employed for both surfactants. The procedure proposed for the determination of anionic surfactant was based on the substitution reaction of orange methyl (MO) by anionic surfactant (sodium dodecylbenzene sulfonate - DBS) to form an ion-pair with the cetyl pyridine (CPC) at pH 5.0. The proposed instrumentation allowed the achievement of a lineal response range between 1.4 x 10-6 mol L-1 and 1.4 x 10-5 mol L-1 (0.5 – 5.0 mg L-1) (R = 0.997, n = 7), a detection limit of 9.8 x 10-8 mol L-1 (0.034 mg L-1), a relative standard deviation of 0.8% (n = 11) for a reference solution containing 5.7 x 10-6 mol L-1 (2.0 mg L-1) DBS and sampling throughput of 60 determinations per hour. Results obtained applying the proposed procedure for domestic and industrial effluent samples were compared with those obtained using reference method and no significant differences at the 95 % confidence level was observed. For the determination of cationic surfactant in waters the procedure was developed based on the ternary complex formation between CPC, Fe (III) and chromazurol S at pH 4.5. The proposed system comprised a flow cell device with 40 mm optical path-length presented the following features: a linear response range between 0.1 x 10-5 mol L-1 e 3.0 x 10-5 mol L-1 (0.34 – 10.2 mg L-1) (R = 0.999, n = 9); a detection limit of 1.0 x 10-7 mol L-1 (0.035 mg L-1); a relative standard deviation of 0.6 % (n = 11) for a reference solution containing 1.0 x 10-5 mol L-1 (3.4 mg L-1) CPC; and a sampling throughput of 72 determinations per hour. The procedure was applied to samples waters collected in the Piracicaba River. Using standard addition test recoveries between 91 % and 106 % were observed. The flow network for the sequential determination of anionic and cationic surfactants comprised two solenoid micro-pumps and six solenoid pinch valves. Employing the system proposed for the determination of anionic surfactants the folowing analytical characteristics: linear response range between 0.1 x 10-5 mol L-1 e 3.0 x 10-5 mol L-1 (0.35 – 10.5 mg L-1) (R = 0.9992, n = 7); a detection limit of 1.6 x 10-7 mol L-1 (0.056 mg L-1); a relative standard deviation of 0.6 % (n = 11) for a reference solution containing 1.0 x 10-5 mol L-1 (3.5 mg L-1) DBS were observed. For cationic surfactants a linear response range between 0.1 x 10-5 mol L-1 e 3.0 x 10?5 mol L-1 (0.34 - 10.2 mg L-1) (R = 0.9992, n = 7), a detection limit of 1.4 x 10-7 mol L-1 (0.05 mg L-1), a relative standard deviation of 0.5 % (n = 11) for a reference solution containing 1.0 x 10-5 mol L-1 (3.4 mg L-1) CPC were observed. In both cases, the reagents and sample consumption were 400 mL and 200 mL, respectively. The sampling throughput of 60 determinations per hour was achieved for both surfactants. The system was applied to waters samples from the Corumbataí River. The results obtained using the standard addition test presented recoveries between 91 % and 105 %. Applying t-test between the results obtained by the proposed procedures and those obtained using reference procedures showed that for anionic and cationic surfactants, the results were concordant at 95% confidence level."
202

Estudos espectrofotométricos e por quimiluminescência da autoxidação de complexos de Ni(II) ou Cu(II)/tetraglicina induzida por S(IV). Aplicações analíticas / Spectrophotometric and chemiluminescence studies of S(IV) induced autoxidation of Ni(II) or Cu(II)/tetraglycine complexes. Analytical applications.

Rodrigo Leandro Bonifacio 13 May 2004 (has links)
O presente trabalho apresenta estudos da reação de autoxidação de Ni(II)/tetraglicina ou Cu(II)/tetraglicina induzida por S(IV). Estudos espectrofotométricos enfocaram a formação do respectivo íon metálico no estado de oxidação 3+. Verificou-se que S(IV) acelera a autoxidação de Ni(II)/tetraglicina em pH=9,2 (tampão borato), com a determinação de alguns parâmetros cinéticos desta reação. A autoxidação de Cu(II)/tetraglicina induzida por S(IV), caracterizada por efeito sinérgico positivo de Ni(II), foi empregada no desenvolvimento de método analítico para S(IV) na faixa de (0-0,12) milimolar. Este método foi utilizado para estudo da autoxidação de S(IV) catalisada por traços de íons metálicos de transição, em meio não-complexante. Estudos por quimiluminescência abordaram a interação das espécies geradas na autoxidação de Ni(II)/tetraglicina e Cu(II)/tetraglicina induzida por S(IV) com o íon tris-bipiridil-2,2´-rutênio(II). Foi avaliado o efeito de intensificação da radiação emitida, causado por tensoativos ou adições sucessivas de S(IV). A interação das espécies produzidas na autoxidação de Ni(II)/tetraglicina induzida por S(IV) com luminol foi aproveitada para desenvolvimento de método quimiluminescente para determinação de sulfito. O método proposto foi aplicado para determinação de S(IV) livre em amostras de bebidas, açúcar e água de chuva (limite de detecção 0,28 nanomolar). / The current work shows studies concerning the sulfite induced Ni(II)/tetraglycine (NiIIG4) and Cu(II)/tetraglycine (CuIIG4) autoxidation reaction in aqueous medium. Spectrophotometric studies focused on the formation of the correspondent metallic ion in the 3+ oxidation state. It was found that S(IV) accelerates NiIIG4 autoxidation at pH = 9.2 (borate buffer). Some kinetic parameters of this reaction have been successfully determined. S(IV) induced CuIIG4 autoxidation, which is characterized by the remarkable positive synergistic effect of Ni(II), was used in the development of a S(IV) analytical method in the range of (0-12)x10-5 mol L-1. This method was used to study the S(IV) catalyzed autoxidation of metallic transition ions, in non-complexing medium. Chemiluminescence studies approached the interaction between Ru(II)/bipy (tris-bipyridil-2,2´-ruthenium(II) ion) and the species generated in the S(IV) induced NiIIG4 autoxidation. The emitted radiation intensifying effect, which is caused by the presence of certain surfactants or consecutive additions of S(IV), was evaluated. The interaction between the species generated in the S(IV) induced NiIIG4 autoxidation and luminol was used in the development of a sulfite determination method by chemiluminescence. A flow system containing a gas-diffusion unit was used to separate S(IV) from the matrix. Free sulfite was determined in beverages, sugar and rainwater samples, with a detection limit of 2,8 x 10-8 mol L-1.
203

Desenvolvimento de um fotômetro portátil e de procedimentos analíticos automáticos para determinação de ânions e cátions em fontes de captação de águas para uso doméstico e industrial / Development of portable photometer and automatic analytical procedures for anions and cations determination in sources of water captation for domestic and industrial uses

Feres Junior, Mario Almir 18 December 2006 (has links)
Neste trabalho, foi desenvolvido equipamento portátil e procedimentos analíticos automáticos para determinação de cátions e anions em águas usadas para consumo humano e suprimento. Os procedimentos foram baseados no processo de multicomutação em fluxo e detecção fotométrica empregando fotômetro feito no laboratório. Os sistemas de fluxo foram construídos empregando válvulas solenóide, com interface independente de comutação acionadas por computador usando apenas um canal de bombeamento. O sistema proposto foi controlado por um computador rodando um software escrito em QuickBasic 4.5. Os dói fotômetros baseados em LED foram desenvolvidos usando como detectores de radiação foto-transistores e foto-diodos. Nos dois casos a fonte de radiação (LED) e o foto-detector foram acoplados a cela de fluxo obtendo assim, uma unidade compacta. O fotômetro foi projetado para usar um foto-transistor para determinações seqüenciais de nitrato, nitrito, ferro(II), ferro(III) em águas de rios.O fotômetro proposto usa um foto-diodo para determinação de cloreto por turbidimetria, fosfato e amonium por fotometria. A sistema de fluxo foi desenhado associando-se os processos de multicomutação e multisite garantindo redução de reagente e de efluente. O sistema sistema foi empregado para determinação de cloreto, fosfato e amônio em águas de rios. Os dois sistemas propostos apresentaram excelente performance incluindo boa precisão, freqüência analítica e baixo consumo de reagente. Além disso, o sistema baseado em multisite apresentou baixo volume de efluente gerado. As dimensões reduzidas de ambos os fotômetros e do modulo de analise em fluxo, permitiram a portabilidade, o que possibilita sua aplicação em condições de campo. / In this work it was developed a portable apparatus and automatic analytical procedures for the determination of cations and anions in waters used for human consumption and industrial provisioning. The procedures were based on the multicommutation process in flow analysis and detection was performed using a homemade photometer. The flow systems were designed employing a set of solenoid valves, which were assembled to work as independent commutation units, thus under computer control several solutions were handled using a single pumping channel. The proposed system was controlled by computer running a software wrote in QuickBasic 4.5. The two LED based photometers were developed using as light detection a phototransistor and a photodiode. In both cases, the radiation source (LED) and the photodector were coupled to the flow cell in order to obtain compact unit. The photometer designed using a phototransistor was employed for the sequential determination of nitrate, nitrite, iron(II) and iron(III) in river water. The photometer designed using a photodiode was employed in the system used for the determination of chloride by turbidimetry, phosphate and ammonium by photometry. The flow system was designed associating the multisite and multicommutation process intending reduction of the reagent consumption and waste generation. The useful of the system was proved performing the determination of chloride, ammonium and phosphate in river water. The two proposed systems presented very overall performance including precision and accuracy, analytical frequency and low reagent consumption. Furthermore, the system based on multisite approach presented a very low volume of waster generation. The reduced dimensions of both photometer and flow system module allow their portability, thus we can suggest that the proposed systems are reliable for work in field condition.
204

Utilização de resíduos de poliuretano expandido na moldagem por injeção de compósito de matriz de polietileno de alta densidade / Use of expanded polyurethane scrap to injection mold a composite into a high-density polyethylene matrix

Teixeira, André Luiz 03 April 2017 (has links)
Submitted by Milena Rubi (milenarubi@ufscar.br) on 2017-08-16T14:17:38Z No. of bitstreams: 1 TEIXEIRA_Andre_2017.pdf: 23449389 bytes, checksum: c2eafb920ec024ab4ae56b9b0007cff3 (MD5) / Approved for entry into archive by Milena Rubi (milenarubi@ufscar.br) on 2017-08-16T14:17:46Z (GMT) No. of bitstreams: 1 TEIXEIRA_Andre_2017.pdf: 23449389 bytes, checksum: c2eafb920ec024ab4ae56b9b0007cff3 (MD5) / Approved for entry into archive by Milena Rubi (milenarubi@ufscar.br) on 2017-08-16T14:17:53Z (GMT) No. of bitstreams: 1 TEIXEIRA_Andre_2017.pdf: 23449389 bytes, checksum: c2eafb920ec024ab4ae56b9b0007cff3 (MD5) / Made available in DSpace on 2017-08-16T14:17:59Z (GMT). No. of bitstreams: 1 TEIXEIRA_Andre_2017.pdf: 23449389 bytes, checksum: c2eafb920ec024ab4ae56b9b0007cff3 (MD5) Previous issue date: 2017-04-03 / Não recebi financiamento / For a few years now polymeric materials have been ever present around the whole globe. Polyurethane (PU) for example is the sixth most produced polymer globally, generating with that a considerable amount of scrap due to industrialization processes, usage or end of its life cycle. About this, the present dissertation proposes to reprocess industrially discarded PU through mechanical recycling and injection molding to validate reusing this waste, reducing the amount sent to landfill. In order to do that PU scrap was physically mixed with high density polyethylene (HDPE), a commodity polymer, in pellets. PU was obtained from industrial waste of an earplug production process and HPE was bought in local market. PU scrap was obtained as a polymeric blanket that was later milled and micronized. Three different mixtures were manually prepared and placed into an industrial scale injection molding machine which resulted in the production of test specimens of 2%, 5% and 7% in mass of micronized PU into a HDPE matrix. Test specimens were submitted to flexural, tension and impact testing and the results were compared to the properties of 100% virgin specimens and with literature data. The samples indicated that adding PU decreased impact resistance but kept the performance on flexural and tension strengths, even increasing maximum deformation. Regarding thermal properties, the studied material presented the same melt and crystallization temperatures results for Differential Scanning Calorimetry (DSC) as well as loss and storage modulus for Dynamic Mechanical Thermal Analysis (DMTA). Thermogravimetric analysis (TGA) showed a decreased to the mass loss peak temperature when PU percentage increased. Nonetheless, considering all mechanical and thermal properties analyzed, present study shows that reusing the PU scrap is a viable option, given the appropriate process conditions. / Há alguns anos, os materiais poliméricos estão cada vez mais presentes nas indústrias, comércios, residências, enfim, no cotidiano de países do mundo inteiro. O poliuretano (PU), por exemplo, é o sexto tipo mais comum de polímero sintetizado mundialmente, gerando também uma quantidade considerável de resíduo, após o processamento industrial, uso ou fim de vida útil. Neste contexto, este trabalho aborda o reprocessamento, através da reciclagem mecânica e injeção, de poliuretano (PU) descartado industrialmente com a intenção de validar o reaproveitamento desse resíduo, diminuindo seu envio para aterros. Para isto, foram realizadas misturas físicas de resíduos de PU com o polietileno de alta densidade (PEAD), um polímero commodity, em forma de grânulos (pellets). O PU foi obtido de descartes primários do processo de fabricação de protetores auditivos e o PEAD foi comprado regularmente no mercado nacional. O PU de descarte estava no formato de uma manta polimérica que foi submetida à moagem e micronização. Posteriormente, as misturas foram realizadas manualmente e colocadas em injetora de porte industrial, o que permitiu a obtenção de corpos de prova nas proporções de 2%, 5% e 7% em massa de PU moído em relação ao polietileno de alta densidade (PEAD). Os corpos de prova injetados foram, então, submetidos aos ensaios de flexão, de tração e de impacto. Os resultados obtidos foram comparados aos das propriedades de corpos de prova 100% virgem (sem presença do PU) e com a literatura. As amostras indicaram que a adição do PU ocasionou decréscimo na propriedade de resistência ao impacto, mas manteve as propriedades testadas em flexão e tração, apresentando inclusive aumento na deformação máxima quando o PU foi adicionado. Quanto às propriedades térmicas, os materiais obtidos mantiveram os valores das temperaturas de fusão e de cristalização analisadas por DSC (Differential Scanning Calorimetry), bem como os valores de módulos de armazenamento e de perda analisados por DMTA (Dynamic Mechanical Thermal Analysis). De acordo com as análises realizadas por Termogravimetria (TG), foi observado decréscimo da temperatura de pico de perda de massa, quanto maior a presença de poliuretano. No entanto, considerando todas as propriedades mecânicas e térmicas analisadas, o trabalho indicou que é viável, diante de certas condições de processo, o reaproveitamento desse tipo de resíduo de PU.
205

Determinação de polifenóis totais utilizando sistemas de análise por injeção em fluxo. / Determination of total polyphenol using flow injection analysis.

Piccin, Evandro 17 February 2004 (has links)
Made available in DSpace on 2016-06-02T20:36:57Z (GMT). No. of bitstreams: 1 DissEP.pdf: 1396653 bytes, checksum: 663940895afdaa334ba4420083e47789 (MD5) Previous issue date: 2004-02-17 / Financiadora de Estudos e Projetos / In this dissertation, three flow injection analysis methods for total polyphenol determination in tea and acacia s tannins commercial extracts were developed. The first method is based on the reaction between the polyphenol compounds and the metavanadate anion (VO3 -), yielding a colored product with strong absorption at 585 nm. In the flow injection system with merging zones employed, 500 µL of the sample solutions and 500 µL of 0.10 mol L-1 ammonium metavanadate solution were injected into the individual carrier solutions (deionised water). With the reaction development in a 150 cm coil reactor, the chromogenic product formed was monitored spectrophotometrically at 585 nm. The analytical curve was linear in the tannic acid concentrations ranging from 35.7 and 544 mgL-1 (2.1 x 10-5 and 3.2 x 10-4 mol L-1), with a detection limit of 12.9 mg L-1 (7.6x10-6 mol L-1). An analytical sampling of 70 determinations per hour was obtained with relative standard deviations smaller than 0.8 % for tannic acid solutions containing 81.7 and 493 mg L-1 (4.8 x 10-5 and 2.8 x 10-4 mol L-1). Because the recoveries from tea samples varied between 87.3 and 94.2%, the standard multiple additions method was used for total polyphenol determination in these samples. In the second proposed method the same reagent was employed in the determination of the polyphenol compounds. In this case, a single-line flow injection system coupled with a solid phase reactor containing silver metavanadate (AgVO3) immobilized in polyesther resin was employed. In this system, volumes of 500 µL of the sample solutions injected into the carrier solution were converted in the chromogenic product in the solid phase reactor with 10 cm of length containing particles with size ranging from 250 and 300 µm of AgVO3 immobilized in polyesther. The analytical curve was linear in the tannic acid concentrations ranging from 88.5 and 2041 mg L-1 (5.2 x 10-5 e 1.2 x 10-3 mol L-1), with a detection limit of 10.0 mg L-1 (5.9 x 10-6 mol L-1). An analytical sampling of 35 determinations per hour was obtained with relative standard deviations smaller than 1.1 % for tannic acid solutions containing 175 and 1350 mg L-1 (1.0 x 10-4 and 7.9 x 10-4 mol L-1). Since the recoveries from acacia s tannin extracts of samples varied between 98.5 and 104%, the total polyphenol analysis were made directly by the use of an analytical curve. In the third developed method, a flow injection analysis system was employed for turbidimetric determination of total polyphenols, using copper(II) íons in a acetate medium as the precipitin reagent. In this system, 350 µL of reagent solution (0.10 mol L-1 copper(II)) and 350 µL of the sample solutions were injected simultaneously into a merging zones system. After a previous mixing at a 50 cm coil reactor, they receive an 0.10 mol L-1 ammonium acetate solution by confluence. The precipitate formed at a 100 cm coil reactor, was monitored turbidimetrically at 500 nm. A 10-2 mol L-1 HNO3 solution flowing intermittently at 3.5 mL min-1 was used to wash the flow system during the sampling. The determination of polyphenol compounds in tea samples in the concentration range from 18.0 to 725 mg L-1 (1.1 x 10-5 e 4.3 x 10-4 mol L-1) with a detection limit of 6.49 mg L-1 (3.8 x 10-6 mol L-1) for standard solutions of tannic acid was obtained. The analytical sampling was 90 determinations per hour with relative standard deviations smaller than 0.9 % for tannic acid solutions containing 109 and 357 mg L-1 (6.4 x 10-5 and 2.1 x 10-4 mo L-1) (n = 10). Because the recoveries from tea samples varied between 91.4 and 111%, the standard multiple additions method was used for total polyphenol determination in these samples. The results of the sample analysis obtained with the proposed methods were compared with those obtained employing the AOAC official method with relative errors smaller than 6.4%. / Descrevem-se neste trabalho três métodos de análises por injeção em fluxo para determinação de polifenóis totais em amostras de chás e extratos comerciais tanínicos de acácia. O primeiro método baseia-se na reação de oxidação entre os compostos polifenólicos e o ânion metavanadato (VO3 -), originando como produto um cromóforo com forte absorção em 585 nm. No sistema em fluxo com zonas coalescentes empregado, volumes de 500 µL de soluções das amostras e 500 µL de solução de metavanadato de amônio (NH4VO3) 0,10 mol L-1 foram injetados em soluções transportadoras (água deionizada) individuais, percorrendo distâncias iguais até se encontrarem em um ponto de confluência. Com o desenvolvimento da reação em um reator helicoidal de 150 cm, o cromóforo formado foi então monitorado espectrofotometricamente naquele comprimento de onda. A curva analítica foi linear no intervalo de concentrações de ácido tânico entre 35,7 e 544 mg L-1 (2,1 x 10-5 e 3,2 x 10-4 mol L-1), com um limite de detecção de 12,9 mg L-1 (7,6 x 10-6 mol L-1). A freqüência de amostragem foi de 70 determinações por hora com desvios padrões relativos menores que 0,8% para soluções de ácido tânico de 81,7 e 493 mg L-1 (4,8 x 10-5 e 2,8 x 10-4 mol L-1) (n = 10). Como as recuperações em amostras de chás variaram entre 87,3 e 94,2%, empregou-se o método de adição múltipla de padrões para determinação de polifenóis totais nessas amostras. No segundo método proposto empregou-se o mesmo reagente para determinação de polifenóis em amostras de extratos de acácia. A reação química envolvida no segundo método proposto também tem como base a oxidação dos compostos polifenólicos com o ânion metavanadato (VO3 -). Nesse caso, empregou-se um sistema em fluxo de linha única com um reator em fase sólida acoplado contendo metavanadato de prata (AgVO3) imobilizado em resina de polié ster. Nesse sistema, os volumes de 500 µL das soluções das amostras injetadas no fluxo transportador (água deionizada), ao passarem pelo reator em fase sólida com comprimento de 10 cm contendo partículas com tamanhos entre 250 e 300 µm, são convertidas no cromóforo monitorado em 585 nm. A curva analítica foi linear na faixa de concentrações de ácido tânico de 88,5 a 2041 mg L-1 (5,2 x 10-5 e 1,2 x 10-3 mol L-1), com limite de detecção de 10,0 mg L-1 (5,9 x 10-6 mol L-1) e desvios padrões relativos menores que 1,1% (n = 11) para soluções de referência de ácido tânico de 175 e 1350 mg L-1 (1,0 x 10-4 e 7,9 x 10-4 mol L-1). A freqüência de amostragem foi de 35 determinações por hora com recuperações em amostras de extratos tanínicos de acácia entre 98,5 e 104%. A análise de polifenóis totais nessas amostras foi feito diretamente empregando-se uma curva analítica. No terceiro método desenvolvido, um sistema de análises por injeção em fluxo foi empregado para determinação turbidimétrica de polifenóis totais utilizando como reagente precipitante íons Cu2+ em meio de acetato. Nesse sistema, solução do reagente Cu2+ 0,10 mol L-1 e da amostra são injetados simultaneamente em zonas coalescentes em volumes de 350 µL. Após uma prévia mistura em um reator helicoidal de 50 cm, recebem por confluência solução de acetato de amônio 0,10 mol L-1. O precipitado formado em um reator helicoidal de 100 cm foi monitorado turbidimétricamente em 500 nm. Adaptou-se um fluxo intermitente de HNO3 10-2 mol L-1 que efetuasse a limpeza do sistema durante a amostragem. O método foi aplicado em análise de amostras de chás, apresentando uma curva analítica linear no intervalo de concentrações de ácido tânico de 18,0 a 725 mg L-1 (1,1 x 10-5 e 4,3 x 10-4 mol L-1), limite de detecção de 6,49 mg L-1 (3,81 x 10-6 mol L-1) e freqüência de amostragem de 90 determinações por hora. Os desvios padrões relativos foram menores que 0,9% para soluções de ácido tânico de 109 e 357 mg L-1 (6,4 x 10-5 e 2,1 x 10-4 mo L-1) (n = 10). As recuperações nas amostras de chás variaram entre 91,4 e 111%. Sendo assim, empregou-se o método de adição múltipla de padrões para determinação de polifenóis totais em amostras de chás. Os resultados das análises de amostras obtidos empregando-se os três métodos desenvolvidos foram comparados com aqueles obtidos empregando o método oficial da AOAC, com erros relativos menores que 6,4%.
206

Estudo do Processo SAGDOX aplicado a um reservatório de óleo pesado

Martin Júnior, Glen Oliveira 05 March 2018 (has links)
Submitted by Automação e Estatística (sst@bczm.ufrn.br) on 2018-06-05T21:59:56Z No. of bitstreams: 1 GlenOliveiraMartinJunior_DISSERT.pdf: 4637902 bytes, checksum: 14d00f87ce12276fabf401d8ecbcf252 (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2018-06-11T21:26:56Z (GMT) No. of bitstreams: 1 GlenOliveiraMartinJunior_DISSERT.pdf: 4637902 bytes, checksum: 14d00f87ce12276fabf401d8ecbcf252 (MD5) / Made available in DSpace on 2018-06-11T21:26:56Z (GMT). No. of bitstreams: 1 GlenOliveiraMartinJunior_DISSERT.pdf: 4637902 bytes, checksum: 14d00f87ce12276fabf401d8ecbcf252 (MD5) Previous issue date: 2018-03-05 / Conselho Nacional de Desenvolvimento Científico e Tecnológico - CNPq / Os óleos pesados são mais difíceis de serem extraídos, necessitando da aplicação de métodos especiais de recuperação para possibilitar sua produção. A recuperação desse tipo de óleo pode ser incrementada por intermédio de processos térmicos, que consistem basicamente em aumentar a temperatura, reduzindo a viscosidade do óleo e melhorando o seu escoamento. O processo de Drenagem Gravitacional Assistida por Vapor, SAGD (do inglês “Steam-Assisted Gravity Drainage”), é um método já conhecido, provado e utilizado com sucesso em campos ao redor do mundo. A Combustão In-Situ é outro método térmico bastante consolidado. Buscando aperfeiçoar o SAGD, unindo as vantagens deste com os da Combustão In-Situ, foi proposto um novo método denominado “SAGDOX” (do inglês “Steam-Assisted Gravity Drainage with OXygen addition”), patenteado pela Nexen Inc., em 2013. O SAGDOX consiste basicamente em utilizar a estrutura de poços do SAGD, e injetar ar através de um poço injetor vertical, a fim de melhorar a recuperação do óleo. O método está atualmente em estágio de desenvolvimento, com experimentos laboratoriais e em testes de modelos físicos, não contando ainda com testes em campo ou poços-piloto. Nesse trabalho foi realizado um estudo paramétrico do processo SAGDOX aplicado a um reservatório homogêneo contendo óleo pesado, com características do nordeste brasileiro. Os experimentos foram realizados através do simulador computacional STARS, da Computer Modelling Group, considerando-se um tempo de projeto de 20 anos. Foi realizado um planejamento experimental e analisada a produção acumulada de óleo quando submetido a diferentes valores para os seguintes parâmetros operacionais: vazão de injeção de vapor, vazão de injeção de ar, distância entre os poços horizontais, distância do poço injetor de ar e completação do poço injetor de ar. A análise de sensibilidade indicou que todos os parâmetros foram estatisticamente significativos, com a distância entre os poços horizontais sendo o parâmetro mais influente. Injetar oxigênio puro, ao invés de ar, resultou em maiores fatores de recuperação (FR) para os casos analisados. O processo SAGDOX atingiu menores fatores de recuperação quando comparado ao SAGD tradicional, mas mostrou poder antecipar a produção de óleo. / Heavy oil is more difficult to be extracted, it requires the application of enhanced oil recovery (EOR) processes in order to be produced. The recovery of this type of oil can be improved by thermal processes, that consist in elevating the temperature, causing oil viscosity reduction, allowing it to flow better. The Steam-Assisted Gravity Drainage (SAGD) is a well-known method, proved and successfully used around the world. In-situ combustion is another thermal process well consolidated. In order to improve SAGD performance, In-Situ combustion advantages were mixed with SAGD’s, proposing a new process called Steam-Assisted Gravity Drainage with Oxygen addition (SAGDOX), by Nexen Inc., in 2013. SAGDOX basically consists in using the wells structure of SAGD, and add a vertical air injector well, aiming to increase oil recovery. The process is in development stage, with laboratory experimentation and physical model tests, with no field testing or pilots yet. In this paper, it was developed a parametric study of SAGDOX process applied to a heavy oil reservoir, with characteristics from Northeast Region of Brazil. Experiments were conducted using STARS software, a thermal reservoir simulator by Computer Modelling Group, and the project total time was considered 20 years. Experiments were planned using Design of Experiments, and cumulative oil production was analyzed for different values for the following operational parameters: steam injection rate, air injection rate, distance between horizontal wells, distance of air injection well and air injector well completion. Sensibility analysis indicated that all parameters were statistically significant, being the distance between horizontal wells the most influent parameter. Further results indicated that is better to inject pure oxygen, instead of air, leading to higher oil recovery factors. The SAGDOX process reached lower oil recovery factors when compared to traditional SAGD but showed that it can anticipate oil production.
207

Efeitos do parecoxibe subaracnoideo sobre a medula espinal e as meninges de coelhos

Santos, Flávia Maria Leite Virgínio dos January 2018 (has links)
Orientador: Eliana Marisa Ganem / Resumo: Introdução: O parecoxibe, um pró-fármaco hidrolisado à valdecoxibe, é um antagonista da COX-2 com intensa atividade anti-inflamatória e analgésica. Embora muitos estudos tenham sido realizados indicando a eficácia dos antagonistas da COX em aliviar o processo da dor, quase nada foi estudado sobre a toxicidade desses fármacos no neuroeixo. Objetivos: O objetivo desta pesquisa foi avaliar os efeitos que diferentes doses de parecoxibe, administrado pela via subaracnoidea, em punção única, determinariam sobre a medula espinal e as meninges de coelhos. Metodologia: Após aprovação pela Comissão de Ética no Uso de Animais, 30 coelhos adultos jovens, da raça grupo genético de Botucatu, com pesos entre 2510 g e 3560 g, fornecidos pelo Biotério da Faculdade de Medicina de Botucatu, foram randomizados em três grupos: grupo S – solução salina a 0,9%, grupo P4 – parecoxibe (dose: 4 mg) e grupo P8 – parecoxibe (dose: 8 mg). Após a anestesia intravenosa com xilazina e cetamina os animais foram submetidos à punção subaracnoidea guiada por ultrassom, com agulha de Quincke 25G, no espaço entre primeira e a segunda vértebras sacrais e realizada a injeção de uma das soluções previamente sorteadas em volume de 0,4 mL (10 µL por centímetro de medula espinal medida entre a base do crânio e o espaço lombossacral). Após a recuperação da anestesia e por 21 dias, os animais foram avaliados quanto à sensibilidade e à motricidade. Em seguida, foram sacrificados por decapitação e retiradas as porções lomb... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Background: Parecoxib, a pro-drug that is hydrolyzed to valdecoxib, is a COX-2 antagonist with strong anti-inflammatory and analgesic activity. Although many studies have demonstrated the efficacy of COX antagonists in relieving pain, almost nothing is known about the toxicity of these drugs when administered into the neuraxis. Objectives: The aim of this study was to evaluate the effects of a single injection of different doses of parecoxib into the subarachnoid space on the spinal cord and meninges of rabbits. Methods: After approval by the Ethics Committee on Animal Use, 30 young adult rabbits of the Botucatu genetic group weighing 2,510 to 3,560 g, were randomized into three groups: group S - 0.9% saline; group P4 – parecoxib (dose: 4 mg); group P8 – parecoxib (dose: 8 mg). After intravenous anesthesia with xylazine and ketamine, the animals underwent ultrasound-guided subarachnoid puncture with a Quincke 25G needle in the space between the first and second sacral vertebrae and the injection of one of the previously established solutions was performed in a volume of 0.4 mL (10 µL per cm of spinal cord measured from the skull base to the lumbosacral space). After recovery from anesthesia, the animals were evaluated regarding sensitivity and motor function for 21 days. After this period, the animals were sacrificed by decapitation and the lumbar and sacral portions of the spinal cord and the roots of the cauda equina were removed for histological examination by light micros... (Complete abstract click electronic access below) / Doutor
208

Fabricação de pinças de biópsias a partir do processo de micromoldagem de pós metálicos por injeção com aplicação à endoscopia flexível

Oliveira, Alex Sandro Matos de January 2014 (has links)
Neste trabalho foi desenvolvido o projeto e fabricação de quatro componentes de uma pinça de biópsia (concha, garfo, oito e haste), através da micromoldagem de pós metálicos por injeção. A matéria prima utilizada neste trabalho é conhecida comercialmente como CATAMOLD® 316L A. Corpos de prova foram obtidos através da injeção em uma injetora de baixa pressão para determinação da quantidade de pó de aço inoxidável 316L e sistema aglutinante contida na matéria prima. Ensaios de injetabilidade foram realizados para análise do comportamento da matéria prima no processo de injeção. Foram avaliados os parâmetros de injeção (temperatura de injeção, temperatura do molde e velocidade de injeção) e as variáveis de saída (pressão de injeção, massa, segregação entre pó e sistema aglutinante e densidade). A influência dos parâmetros de injeção sobre as variáveis de injeção foi analisada através do delineamento estatístico via Redes Neurais Artificiais (RNA), com a utilização do programa Statgraphics® Centurion XV. Os corpos de prova obtidos na injetora de baixa pressão apresentaram alta quantidade de pó de aço inoxidável (92,2% em massa). Devido a esta alta concentração de pó, os ensaios de injetabilidade realizados na injetora de alta pressão apresentaram valores elevados para as pressões de injeção, variando de 1641 a 2115 bars para que houvesse o preenchimento total das cavidades. O molde microusinado para os componentes da pinça se mostrou eficiente na fabricação dos componentes, porém apresentou dificuldades na extração das peças. Mesmo com a obtenção de todos os componentes a montagem da pinça não foi realizada, visto que as furações de montagem foram retiradas no projeto, consequentemente não foram usinados. Depois de microinjetados, os componentes da pinça foram sinterizados e apresentaram variação dimensional de 0,01 a 0,29 mm em relação às dimensões de projeto e variação na contração de 7,05 a 13,33%, diferentes dos 14,30% citados no catálogo do CATAMOLD® 316L A. / In this work the design and manufacture of four components of the biopsy forceps (ladle, fork, eight and rod), by metal powder injection molding was developed. The feedstock used in this work is known commercially as CATAMOLD® 316L A. Specimens were obtained by injection into a low-pressure injection molding machine for determining the amount of 316L stainless steel powder and binder system contained in the feedstock. Mouldability tests were performed to analyze the behavior of the feedstock in the injection process. The injection parameters (injection temperature, mold temperature and injection speed) and output variables (injection pressure, mass segregation between powder and binder system and density) were evaluated. The influence of injection parameters on the variables of injection was analyzed using the statistical design via Artificial Neural Networks (ANN), using the software Statgraphics® Centurion XV. The specimens obtained at low pressure injection showed high amount of stainless steel powder (92.2 wt%). Due to this high concentration of power, mouldability tests were performed in high-pressure injection showed high values for injection pressures ranging from 1641 to 2115 bars so that there was the complete filling of cavities. The micromachined mold for the components of the forceps proved efficient in the manufacture of components, but presented difficulties in the extraction of parts. Even with the obtaining of the all the components the biopsy forceps was not assembled, since the mounting holes were taken in the project, and therefore were not machined. After injected , the components of the forceps were sintered and showed dimensional variation from 0.01 to 0.29 mm in relation to project dimensions and variation in contraction from 7.05 to 13.33% , different from those 14.30% cited in the catalog of CATAMOLD® 316L A
209

Desenvolvimento de ímãs de Nd-Fe-B pelo processo MPI- aplicados em máquinas elétricas (motores)

Luna, Wilberth Harold Deza January 2012 (has links)
O processo tradicional de fabricação de ímãs de terras raras – TR – é a metalurgia do pó convencional. Este processo inclui etapas de preparação da liga, moagem, compactação sob campo e sinterização. Atualmente, ímãs obtidos pelo processo de injeção tem como resultado os ímãs conhecidos como bonded, que são compósitos de resina e ligas magnéticas. O processo de obtenção proposto neste trabalho é a moldagem de pós por injeção – MPI, o que implica novos desafios uma vez que ligas de terras raras são altamente reativas. A obtenção de ímãs de Nd-Fe-B por esse processo fornece a oportunidade de diversificar ainda mais os setores, potencialmente lucrativos, que trabalham com materiais magnéticos. As dificuldades desse processo foram encontradas em cada etapa, desde a mistura da liga com os polímeros à eliminação destes polímeros depois de as peças serem injetadas, essa etapa se tornou crítica dado que está diretamente relacionada às propriedades finais do material. Assim, propuseram-se novos ciclos de extração dos polímeros com solventes orgânicos e degradação térmica. Além disso, modelou-se ferramental para o processo de injeção, uma vez que o material deve ser orientado magneticamente durante a injeção. Finalmente usou-se o MAXWELL 14® (software para análises por elementos finitos para resolução em 3D) para incluir propriedades no banco de dados do software e assim predizer o comportamento do material quando aplicado nas máquinas elétricas de núcleos com de formato complexo. / The typical magnets production process of Rare Earths – RE is the conventional powder metallurgy. This process includes preparation stages of alloys, grind, pressing under field and sintering. Nowadays, magnet obtained by the injection process has as result the magnets known as bonded, that is a resin composite and magnetic alloys. The proposed process to obtainment, in this work, is the Metal Injection Molding- MIM, what involve new challenges once alloys of RE are highly reactive. The magnets obtainment of ND-Fe-B for this process supplies even opportunity of diversifying the sectors, potentially lucrative, that work with magnetic materials. The difficulties of this process were found in each stage, since the alloy mixture with the polymers to the elimination of these polymers after the pieces are injected, this stage became criticizes given it is directly related to final properties of the material. This way if it propose to polymers extraction new cycles with organic solvents and thermal degradation. Moreover, it modeled die for the injection process, once the material should be guided magnetically during the injection. It finally used MAXWELL 14 ® (Software for analyses by finite elements for resolution in 3D) to include properties on the bench of data of the software and thus predict the material behavior when applied in cores of electrical machines with complex shape.
210

Ligante ecofriendly à base de borracha natural para o processo de moldagem por injeção de pó de ferro

Escobar, Camila Ferreira January 2017 (has links)
O processo de moldagem de pós por injeção (MPI) é uma tecnologia relativamente recente e permite a fabricação de peças e componentes de diversos materiais, com a possibilidade de fabricar peças em larga escala. O processo MPI é composto por quatro etapas: mistura do pó com o material orgânico (ligante), moldagem por injeção, extração do ligante e sinterização. O ligante é um veículo temporário composto por polímeros e/ou ceras e sua função é possibilitar o escoamento da carga injetável para o molde durante a moldagem por injeção e após a moldagem este deve ser totalmente removido da peça. A maioria dos polímeros utilizados no ligante é oriunda do petróleo, que é uma fonte não renovável que gera sérios impactos ambientais. Neste estudo foi proposto a utilização de ligante à base de borracha natural, que além de ser proveniente de fonte renovável, confere elasticidade à peça moldada, que possibilita a fácil desmoldagem de peças com geometria complexa e pequenas espessuras. Também se analisou a substituição da parafina, que estudada em trabalhos anteriores em ligante para injeção de alumina com a borracha natural, pela cera de carnaúba na moldagem por injeção de pó de ferro metálico. Foram avaliados três ligantes à base de borracha natural e as ceras: (i) parafina, (ii) cera de carnaúba e (iii) parafina + cera de carnaúba e estudou-se o efeito da composição do ligante em cada etapa do processo MPI. Investigou-se as propriedades químicas e térmicas dos ligantes, o teor de pó admissível nas cargas injetáveis, as rotas de remoção do ligante por via térmica e solvente e as propriedades finais como retração linear, porosidade, microestrutura e resistência à flexão. As composições de ligante a base de borracha natural e cera de carnaúba proporcionaram melhores propriedades ao processo MPI. Nestas composições foi possível a moldagem por injeção de cargas injetáveis com maior teor de pó, apresentaram maior estabilidade reológica, em que a viscosidade apresentou baixa variação em relação à temperatura e maior estabilidade com o aumento do teor de pó. Além disso, foram as únicas amostras que não apresentaram defeitos durante a extração por solvente e apresentaram propriedades finais satisfatórias para o processo MPI de ferro. / The Powder Injection Molding process (PIM) is a relatively new technology and allows the manufacturing of parts and components of various materials, with the possibility of fabricating parts in microscale. The PIM process is composed of four steps: mix the powder with the organic material (binder), injection molding, extraction of the binder and sintering. The binder is a temporary vehicle composed of polymers and/or waxes and its function is to allow the flow of the feedstock into the mold during injection molding, and after molding this should be completely removed from the sample. Most of the polymers used in the binder are derived from petroleum, which is a non-renewable source that generates serious environmental impacts. In this study, it was proposed the use of binder based on polymer and wax from renewable sources that reduce the environmental impact. It was analyzed the substitution of paraffin, which was studied in previous studies with natural rubber, by the carnauba wax in the injection molding of the iron carbonyl. Were evaluated three binders based on polymer and wax: (i) paraffin, (ii) carnauba wax and (iii) paraffin wax carnauba wax and we studied the binder composition effect in each step of PIM process. The chemical and thermal binder properties, the critical powder volume concentration, the solvent and thermal debinding and the sintered properties were analyzed. As results, we found that the natural rubber and carnauba wax binder have better PIM process properties. In this binder was possible an injection molding with higher powder content, showing higher rheological stability, which the viscosity was more stable under temperature and powder content variation. Furthermore, the samples with this binder shown no defects after solvent debinding and suitable sintered properties for the iron PIM process.

Page generated in 0.2908 seconds