• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 417
  • 7
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 428
  • 258
  • 235
  • 129
  • 125
  • 98
  • 84
  • 83
  • 80
  • 78
  • 64
  • 51
  • 49
  • 45
  • 43
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
281

Determinação a baixo custo de açúcares redutores totais em caldo-de-cana, empregando sistemas de análise por injeção em fluxo com o uso de DNS / Low cost determination of total reducing sugars in sugar cane broth using a flow injection analysis system with DNS

Barros, Osmar Soares 28 April 2005 (has links)
Determinação a baixo custo de açúcares redutores totais em caldo-de-cana, empregando sistema de análise por injeção em fluxo com o uso de DNS Um sistema de análise por injeção em fluxo foi utilizado para a determinação de açúcares redutores totais em caldo-de-cana. O método é baseado na hidrólise da sacarose, seguido da oxidação dos açúcares redutores pelo ácido 3,5-dinitrosalicílico (DNS) em meio alcalino, e determinação espectrofotométrica em 510 nm. Visando obter melhor sensibilidade e seletividade, os parâmetros volume de amostra e comprimento dos reatores foram estudados para avaliar o comportamento das curvas analíticas. Foram utilizados mini-compressores de aquários no lugar de bomba peristálticas e cela espectrofotométrica em acrílico no lugar de cela de vidro importada, a fim de minimizar o consumo de reagentes e o custo do sistema FIA. O presente sistema foi comparado ao método Lane-Eynon recomendado pelo Ministério da Agricultura. Usando o teste-t, não foram constatadas diferenças significativas entre os resultados dos dois métodos, sendo que os desvios relativos foram ao redor de 1%. O método permite analisar cerca de 14 amostras h-1 com desvio padrão relativo inferior a 1,35%. / A flow injection analysis system was employed for determination of total reducing sugars in sugar cane broth. The method is based on hydrolysis of sucrose followed by oxidation of reducing sugars by 3,5-dinitrosalicylic acid (DNS) in alkaline solution and spectrophotometric determination at 510 nm. In order to obtain better sensitivity and selectivity, the parameters sample volume and reactor length were studied to evaluate the behavior of the analytical curves. Aiming the use of low reagents amount and a low cost in FIA system, fish aquarium mini-compressors were used instead of peristaltic pumps and acrylic spectrophotometric 0011 instead of imported glass cell. The present system was compared to Lane-Eynon method recommended by the Brazilian Ministry of Agriculture. Using the t-test no sígnificant differences were observed between both methods, with relative deviations around of 1%. The method allows analyses of ca. 14 samples h-1 with relative standard deviation lower than 1.35%.
282

Desenvolvimento e avaliação de métodos de extração e separação cromatográfica em colunas monolíticas e superficialmente porosas para determinação de herbicidas triazínicos em solos e águas / Development and evaluation of extraction and chromatographic methods in monolithic and core-shell columns for determination of triazine herbicides in soils and waters

Urio, Ricardo De Prá 10 December 2015 (has links)
O uso de pesticidas levou ao aumento da produtividade e qualidade dos produtos agrícolas, porém o seu uso acarreta na intoxicação dos seres vivos pela ingestão gradativa de seus resíduos que contaminam o solo, a água e os alimentos. Dessa forma, há a necessidade do monitoramento constante de suas concentrações nos compartimentos ambientais. Para isto, busca-se o desenvolvimento de métodos de extração e enriquecimento de forma rápida, com baixo custo, gerando um baixo volume de resíduos, contribuindo com a química verde. Dentre estes métodos destacam-se a extração por banho de ultrassom e a extração por ponto nuvem. Após o procedimento de extração, o extrato obtido pode ser analisado por técnicas de Cromatografia a Líquido de Alta Eficiência (HPLC) e a Cromatografia por Injeção Sequencial (SIC), empregando fases estacionárias modernas, tais como as monolíticas e as partículas superficialmente porosas. O emprego de SIC com coluna monolítica (C18, 50 x 4,6 mm) e empacotada com partículas superficialmente porosas (C18, 30 x 4,6 mm, tamanho de partícula 2,7 µm) foi estudado para separação de simazina (SIM) e atrazina (ATR), e seus metabólitos, desetilatrazina (DEA), desisopropilatrazina (DIA) e hidroxiatrazina (HAT). A separação foi obtida por eluição passo-a-passo, com fases móveis compostas de acetonitrila (ACN) e tampão Acetato de Amônio/Ácido acético (NH4Ac/HAc) 2,5 mM pH 4,2. A separação na coluna monolítica foi realizada com duas fases móveis: MP1= 15:85 (v v-1) ACN:NH4Ac/HAc e MP2= 35:65 (v v-1) ACN:NH4Ac/HAc a uma vazão de 35 µL s-1. A separação na coluna com partículas superficialmente porosas foi efetivada com as fases móveis MP1= 13:87 (v v-1) ACN: NH4Ac/HAc e MP2= 35:65 (v v-1) ACN:NH4Ac/HAc à vazão de 8 µL s-1. A extração por banho de ultrassom em solo fortificado com os herbicidas (100 e 1000 µg kg-1) resultou em recuperações entre 42 e 160%. A separação de DEA, DIA, HAT, SIM e ATR empregando HPLC foi obtida por um gradiente linear de 13 a 35% para a coluna monolítica e de 10 a 35% ACN na coluna com partículas superficialmente porosas, sendo a fase aquosa constituída por tampão NH4Ac/HAc 2,5 mM pH 4,2. Em ambas as colunas a vazão foi de 1,5 mL min-1 e o tempo de análise 15 min. A extração por banho de ultrassom das amostras de solo com presença de ATR, fortificadas com concentrações de 250 a 1000 µg kg-1, proporcionou recuperações entre 40 e 86%. A presença de ATR foi confirmada por espectrometria de massas. Foram realizados estudos de fortificação com ATR e SIM em amostras de água empregando a extração por ponto nuvem com o surfactante Triton-X114. A separação empregando HPLC foi obtida por um gradiente linear de 13 a 90% de ACN para a coluna monolítica e de 10 a 90% de ACN para a coluna empacotada, sempre em tampão NH4Ac/HAc 2,5 mM pH 4,2. Em ambas as colunas a vazão foi de 1,5 mL min-1 e o tempo de análise 16 min. Fortificações entre 1 e 50 µg L-1 resultaram em recuperações entre 65 e 132%. / The use of pesticides has led to increased productivity and quality of agricultural products, but its use brings the intoxication of living beings by the gradual intake of their residues that contaminate soil, water and food. Thus, there is the need for constant monitoring of their concentrations in environmental compartments. For this, there is a quest for development of fast extraction and enrichment methods, at low cost, generating a low volume of waste, contributing to green chemistry. These methods include the extraction assisted by ultrasound bath and the cloud point extraction. After the extraction, the extract obtained can be analyzed by techniques such as High Performance Liquid Chromatography (HPLC) and Sequential Injection Chromatography (SIC) employing modern stationary phases, such as monolithic and superficially porous particles. The use of SIC with either monolithic column (C18, 50 x 4.6 mm) or column packed with superficially porous particles (C18, 30 x 4.6 mm, 2.7 µM particle size) was studied for separating simazine (SIM) and atrazine (ATR), and metabolites, deethylatrazine (DEA), deisopropylatrazine (DIA) and hydroxyatrazine (HAT). Separation was obtained by stepwise elution, with a mobile phase consisting of acetonitrile (ACN) and 2.5 mM ammonium acetate / acetic acid (NH4Ac / HAc) pH 4.2 buffer. The separation was performed with two mobile phases: MP1 = 15:85 (v v -1) ACN: NH4Ac / HAc and MP2 = 35:65 (v v-1) ACN: NH4Ac / HAc at a flow rate of 35 µL s-1. The separation in the column with superficially porous particles was carried out with the mobile phases MP1 = 13:87 (v v-1) ACN: NH4Ac / HAc and MP2 = 35:65 (v v-1) ACN: NH4Ac / HAc at 8 µL s-1. The ultrasound bath extraction from a soil fortified with herbicides (100 and 1000 µg kg-1) resulted in recoveries between 42 and 160 %. Separation of DEA, DIA, HAT SIM and ATR was obtained by HPLC employing a linear gradient from 13 to 35% for the monolithic column and from 10 to 35% ACN in the column packed with superficially porous particles, with the aqueous phases consisting of 2.5 mM NH4Ac / HAc buffer pH 4.2. In both columns the flow rate was 1.5 mL min-1 and the analysis time was15 min. Ultrasonic extraction from a soil sample containing ATR, fortified with concentrations from 250 to 1000 µg kg-1, provided recoveries between 40 and 86%. The presence of ATR was confirmed by mass spectrometry. Fortification studies with ATR and SIM were carried out in water samples employing cloud point extraction using Triton-X114 surfactant. The separation was accomplished by HPLC using a linear gradient from 13 to 90 % of ACN for the monolithic column and from 10 to 90 % ACN for the packed column, always in 2.5 mM NH4Ac / HAc pH 4.2 buffer. In both columns the flow rate was 1.5 mL min -1 and the analysis time 16 min. Fortifications between 1 and 50 µg L-1 resulted in recoveries between 65 and 132%.
283

Determinação espectrofotométrica catalítica de molibdênio e ferro explorando calibração multivariada em um sistema de análises químicas em fluxo / Catalytic spectrophotometric determination of Mo(VI) and Fe(III) exploiting multivariate calibration implemented in a flow system

Oliveira, Eliézer de 30 November 2015 (has links)
Os efeitos catalíticos de Mo(VI) e Fe(III) na oxidação de iodeto por peróxido de hidrogênio foram explorados visando à determinação simultânea destes. Diferenças nas taxas de reação foram alcançadas através do estabelecimento de duas zonas reacionais distintas para alteração das cinéticas reacionais. Para isto, foi projetado um sistema de análises por injeção em fluxo que permite a inserção de duas alíquotas de amostra, sendo adicionado ácido sulfúrico em uma destas com formação de uma zona de amostra complexa. Cada elemento de fluido desta zona é caracterizado por composição química, tempo de residência e taxa de reação específicas. Os principais parâmetros que afetam a taxa reacional, tais como concentração dos reagentes, comprimento do reator e vazão total, dentre outros, foram avaliados buscando melhoria na sensibilidade e discriminação cinética entre os analitos. Os comprimentos das alças de amostragem e da bobina separadora foram avaliados construindo-se modelos matemáticos visando máxima discriminação nas previsões para os analitos. Os modelos foram construídos a partir da ferramenta quimiométrica PLS (Partial Least Squares) utilizando os dados gerados por medidas de máximos e mínimos ao longo da zona de amostra. O conjunto de calibração era composto por misturas de Mo(VI) e Fe(III) na faixa de concentrações 6,2 - 50,0 ?g L-1 e 0,5 - 7,0 mg L-1, respectivamente. O modelo selecionado apresenta boa habilidade de previsão com valores de RMSEP estimados como 0,67 ?g L-1 para Mo(VI) e 0,21 mg L-1 para Fe(III). Recuperações entre 85 e 114% foram obtidas para amostras de águas naturais. O sistema proposto apresenta estabilidade física, boa repetibilidade entre as leituras (d. p. r. < 2 %), velocidade analítica de 31 h-1 e consumo de 54 mg de iodeto de potássio e 0,30 mg de peróxido de hidrogênio por amostra / The catalytic effects of Mo(VI) and Fe(III) in the oxidation of iodide by hydrogen peroxide were exploited aiming at their simultaneous determination. Differences in reaction rates were achieved by establishing of two distinct reactions zones to modify the reaction kinetics involved. To this end, a flow injection system allowing insertion of two sample aliquots was designed, and sulfuric acid was added to one of the aliquots. A complex sample zone was then established. Each fluid element of this zone was characterized by a given chemical composition, residence time and reaction rate. The main parameters affecting the reaction rate, such as reagent concentrations, analytical path length and total flow rate, among others, were evaluated for improving sensitivity and analyte kinetic discrimination. Influences of sampling loop lengths and distance between initial plugs were studied, and mathematical models were constructed aiming at improved discrimination in prediction of analytes. The models were constructed from the PLS (Partial Least Squares) chemometric tool using data generated by measurements performed on sample zone regions with maximum and minimum local concentrations. The calibration set consisted of Mo(VI) and Fe(III) mixtures in concentration ranges of 6.2 - 50.0 ?g L-1 and 0.5 - 7.0 mg L-1, respectively. The selected model is characterized by good prediction ability prediction, as RMSEP values were estimated as 0.67 ?g L-1 for Mo(VI) and 0.21 mg L-1 for Fe(III), respectively. Recoveries within the 85 - 114% range were obtained for natural waters. The proposed system presents physical stability and favorable characteristics of measurement repeatability (r.s.d.<2%), sampling rate (31 h-1) and reagent consumption (54 mg of KI and 0.30 mg H2O2 per sample)
284

Sistema de análise em fluxo empregando geração eletroquímica de reagente e detecção biamperométrica para a determinação de sulfito

PAULA, Nattany Tayany Gomes de 12 March 2015 (has links)
Submitted by (lucia.rodrigues@ufrpe.br) on 2017-02-15T14:00:25Z No. of bitstreams: 1 Nattany Tayany Gomes de Paula.pdf: 885461 bytes, checksum: 787ab63496a1306c113ee5c12e2dac92 (MD5) / Made available in DSpace on 2017-02-15T14:00:25Z (GMT). No. of bitstreams: 1 Nattany Tayany Gomes de Paula.pdf: 885461 bytes, checksum: 787ab63496a1306c113ee5c12e2dac92 (MD5) Previous issue date: 2015-03-12 / Sulfites are considered food additives that after chemical reaction releasing sulfur dioxide (SO2), sulfite ion (SO32-), or bisulfite ion (HSO3-). These additives act as antioxidants in food, in the control of bacterial growth and enzymatic and non-enzymatic browning reactions during processing and storage. Although widely used in the food industry, the use of sulfite as a preservative causes some problems, reducing the nutritional quality of foods processed and in some cases are caused adverse effects to human health. In this work it is proposed to determine sulfite in samples of processed juices and wines through an analytical flow system with biamperometric detection. The system was built employing a peristaltic pump, proportional injector, a Gas Diffusion Cell (GDC) and Reagent Generation Cell (RGC) and polyethylene tubes with an internal diameter of 0.8 mm for making the analytical path. The RGC was coupled to a potentiostat for applying current to the electrochemical generation of triiodide ions. For detection it was used a biamperometric detector, adapted to a coulometer for applying the constant potential. For the data acquisition and processing was performed using a software developed in Lab View® language. The analysis method was based on a redox reaction between the I3- ions SO32- and providing a decrease of the generated current by the pair and this decrease in the signal is proportional to the concentration of SO32- ions. After the system optimization, the proposed procedure was operated with KI concentrations of 0.25 mol L-1, HCl 1.0 mol L-1, Na2SO4 and 0.1 mol L-1, with 0.25 mA current applied in RGC and the length of the sampling loop was of 20 cm. In the proposed procedure, a linear response was obtained between 1 and 12 mg L-1 of sulfite E = - (0,2371 ± 0,0028) C + (6,7097 ± 0,0182), R = -0,9997), LD = 0,26 mg L-1 and LQ = 0,86 mg L-1, relative standard deviation less than 2% (n = 10), with sampling frequency of 40 h−1. Potential interfering studies demonstrated the selectivity of the proposed method. Addition and recovery tests with samples of juices and wines were performed to give results of recovery between 91.63 and 110.34%, demonstrating the possibility of operation of the proposed procedure in real samples. / Os agentes sulfitantes ou sulfitos são considerados aditivos alimentares que, após reação química, liberam dióxido de enxofre (SO2), íon sulfito (SO32-) ou íon bissulfito (HSO3-). Estes aditivos são agentes multifuncionais e atuam como antioxidantes em alimentos, no controle do crescimento bacteriano e de reações (enzimáticas e não enzimáticas) de escurecimento durante o processamento e estocagem. Mesmo sendo muito utilizado na indústria de alimentos, o emprego de sulfitos como conservantes provoca alguns problemas, reduzindo a qualidade nutricional dos alimentos tratados e em alguns casos são provocados efeitos adversos à saúde humana. Neste trabalho propõe-se determinar sulfitos em amostras de sucos industrializados e vinhos empregando um sistema de análise em fluxo com detecção biamperométrica. O sistema foi construído empregando-se uma Bomba Peristáltica, um Injetor Proporcional, uma Câmara de Difusão Gasosa (CDG) e uma Câmara de Geração de Reagente (CGR). A CGR foi acoplada a um potenciostato para a aplicação de corrente necessária para a geração eletroquímica de íons triiodeto. Para detecção foi utilizado um detector biamperométrico. Para o tratamento e aquisição de dados, foi utilizado um software desenvolvido em linguagem Lab View®. A metodologia de análise foi baseada em uma reação de oxirredução entre os íons SO32- e I3-, que proporciona uma diminuição da corrente biamperométrica gerada pelo par redox I3-/I-, sendo essa diminuição de corrente proporcional a concentração de íons SO32-. Após a otimização do procedimento proposto obteve-se as melhores condições: 0,25 mol L-1 de KI, 1,0 mol L-1 de HCl, 0,1 mol L-1 de Na2SO4, corrente de 0,25 mA aplicada na CGR e volume de amostra de 100 μL. Nestas condições, obteve-se uma resposta linear entre 1 e 12 mg L-1 de sulfito (I = - (0,2371 ± 0,0028) C + (6,7097 ± 0,0182), R = -0,9997), LD = 0,26 mg L-1 e LQ = 0,86 mg L-1, desvio padrão relativo menor que 2% (n = 10), com frequência de amostragem de 40 determinações por hora. Estudos de potenciais interferentes demonstraram a seletividade do método proposto. Testes de adição e recuperação com amostras de sucos e vinhos foram realizados, obtendo-se resultados de recuperação entre 91,63 e 110,34%, demonstrando a possibilidade de operação do procedimento proposto em amostras reais.
285

Eficácia da articaína, da bupivacaína e da lidocaína associadas à epinefrina em pacientes com pulpite irreversível em molares mandibulares / Efficacy of articaine, of bupivacaine and lidocaine and in patients associated with irreversible pulpitis in mandibular molars

Roberta Moura Sampaio 13 March 2015 (has links)
O objetivo deste estudo foi comparar a eficácia anestésica da articaína 4%, da lidocaína 2%, ambas associadas à epinefrina 1:100.000, e da bupivacaína 0.5%, associada à epinefrina 1:200.000, durante pulpectomia em pacientes com pulpite irreversível em molares inferiores. Cento e cinco voluntários do Setor de Urgência da Faculdade de Odontologia da Universidade de São Paulo receberam, aleatoriamente, 3,6mL de um dos anestésicos locais para o convencional bloqueio do nervo alveolar inferior (BNAI). No caso de falha do BNAI, foram administrados 3,6mL da mesma solução como injeção complementar no ligamento periodontal. O sinal subjetivo de anestesia do lábio, a presença de anestesia pulpar e ausência de dor durante a pulpectomia foram avaliados, respectivamente, por indagação ao paciente, por meio do aparelho estimulador pulpar elétrico (pulp tester) e por uma escala analógica verbal. A análise estatística foi realizada por meio dos testes Qui-quadrado, Kruskal Wallis e Razão de Verossimilhanças. Foi adotado nível de significância de 0,05 (P <= 0,05). Todos os pacientes reportaram anestesia no lábio após o BNAI. A lidocaína apresentou valores superiores (42,9%) para a anestesia pulpar após o BNAI e após a injeção no ligamento periodontal (61,5%). A bupivacaína apresentou valores superiores para a analgesia (80%) após o BNAI e a lidocaína (92,3%) após a injeção no ligamento periodontal. Após a falha do BNAI, a dor na câmara pulpar foi a mais frequente para articaína e lidocaína e na dentina para a bupivacaína e após a falha da injeção no ligamento periodontal, a dor foi similar para articaína nas diferentes regiões; câmara, canal e dentina; para a bupivacaína foi mais frequente na dentina e para a lidocaína no canal. No entanto, essas diferenças não foram estatisticamente significantes. Portanto as três soluções anestésicas locais se comportam de forma semelhante e não apresentam efetivo controle da dor no tratamento da pulpite irreversível em molares inferiores. / The aim of this study was to compare the anesthetic efficacy of 4% articaine and 2% lidocaine both associated with 1:100,000 epinephrine and 0.5% bupivacaine associated with 1:200,000 epinephrine in patients with irreversible pulpitis of the mandibular molars during a pulpectomy procedure. One hundred and five volunteers from the Emergency Center of the School of Dentistry at University of São Paulo randomly received 3.6 mL of local anesthetic as a conventional inferior alveolar nerve block (IANB). The subjective signal of lip numbness, pulpal anesthesia and the absence of pain during the pulpectomy procedure were, respectively, evaluated by questioning the patient, stimulation using an electric pulp tester and a verbal analogue scale. Statistical analysis was performed using the chi-square test, Kruskal Wallis and likelihood rations. The level for significance of differences was P <= .05. All patients reported the subjective signal of lip numbness after the application of either IANB. Lidocaine showed higher values for pulpal anesthesia after the IANB (42.9%) and after injection in the periodontal ligament (61.5%). Bupivacaine presented higher values for analgesia after the IANB (80,0%) and lidocaine after injection in the periodontal ligament (92,3%). After the failure of the IANB, the pain in the pulp chamber was the most frequent to articaine and lidocaine and bupivacaine for dentin and after the failure of the periodontal ligament injection, the pain was equal to articaine in different regions, chamber, canal and dentin; for bupivacaine was greater in dentin and lidocaine was higher in the channel. However, these differences were not statistically significant. So the three local anesthetic solutions behave similarly and not present any effective pain control in the treatment of irreversible pulpitis in mandibular molars.
286

Desenvolvimento de procedimentos analíticos limpos empregando multicomutação em sistemas de análises em fluxo para determinação fotométrica de cobalto e cádmio em águas / Development of clean analytical procedures employing multicommutation flow analysis systems for photometric determination of cobalt and cadmium in waters

Ticiane Silva Gondim 12 December 2016 (has links)
Esse trabalho tem como objetivo o desenvolvimento de procedimentos analíticos automáticos, empregando o processo de multicomutação em fluxo para determinação espectrofotométrica de cobalto e cádmio em amostras de águas. O trabalho envolveu o desenvolvimento dos módulos de análises para implementar os procedimentos analíticos baseados no processo de multicomutação, o sistema de detecção fotométrica empregando LED como fonte de radiação eletromagnética, o software para controle do módulo de análise e para efetuar aquisição de dados. O módulo de análise para determinação de cobalto foi desenvolvido, utilizando mini-bombas solenóide para o bombeamento das soluções. O procedimento analítico foi baseado na catálise do cobalto na reação de oxidação do Tiron pelo peróxido de hidrogênio e com o sistema de detecção espectrofotométrica com LED com emissão em 425 nm. Após os ajustes necessários do módulo de análise o sistema apresentou bom desempenho analítico. Para a determinação de cobalto em águas foram obtidas as seguintes características analíticas: desvio padrão relativo de 0,04 % (n = 13) para uma amostra com 0,5 &micro;gL-1 de Co, faixa de resposta linear entre 0,13 a 1,5 &micro;gL-1 de Co (R = 0,998, n = 3), limite de detecção de 0,06 µgL-1, frequência analítica de 42 determinações por hora e geração de 1,5 mL de resíduo por determinação. Recuperações entre 84 e 114 % foram obtidas com adição de Co (II) nas amostras de águas. O módulo de análise para determinação cádmio foi desenvolvido e otimizado utilizando duas mini-bombas peristálticas para bombeamento das soluções e esvaziamento do percurso, uma válvula solenoide de três vias e três válvulas solenoide de duas vias, uma cela de fluxo com longo caminho óptico (100 mm) e LED com emissão em 520 nm. O procedimento analítico para a determinação do cádmio foi baseado na formação do complexo pelo Cd (II) com o reagente ditizona em meio micelar com o surfactante Triton X100. O procedimento apresentou faixa de resposta linear de 15,0 a 175,0 &micro;gL-1 de Cd (R = 0,997; n = 3), limite de detecção de 12,5 &micro;gL-1, desvio padrão relativo de 0,57 % (n = 10) para uma amostra de 30 &micro;gL-1 e frequência analítica de 43 amostras por hora. Recuperações entre 84 e 112 % foram obtidas com adição de Cd (II) nas amostras de águas. / This work deals with the development of automatic analytical procedures, based on multicommuted flow analysis process for spectrophotometric determination of cobalt and cadmium in water samples. The work involved the development of the analytical modules and the photometric detector using LEDs as electromagnetic radiation sources. The software to control the flow analysis module and to perform data acquisition, were developed using Quick BASIC4.5 as programming language. The analysis module for cobalt determination, employed solenoid mini-pumps for solutions pumping. The procedure was based on the cobalt catalytic effect on the Tiron oxidation by hydrogen peroxide and the photometric detection at 425 nm. After the necessary adjustments of the flow analysis module, the system showed good analytical performance. The following analytical characteristics for determination of cobalt in water were obtained: a relative standard deviation of 0.04% (n = 13) for a standard solution 0.5 &micro;gL-1 Co, a linear response ranging from 0.13 to 1.5 &micro;gL-1 Co (R = 0.998, n = 3), a detection limit of 0.06 &micro;gL-1, analytical frequency of 42 samples determination per hour and a waste generation of 1.5 mL per determination. Recoveries between 84 and 114% were obtained with the addition of Co (II) in water samples. The analytical module for determination of cadmium was developed, using two peristaltic mini-pumps and solenoid valves. The LED based photometer was furnished with a flow cell of long optical path (100 mm) and a LED with maximum emission at 520 nm. The flow analysis module was assembled with ability to perform a closed loop strategy, which was implemented to improve sensitivity. The analytical procedure for the determination of cadmium was based on reaction of Cd (II) with dithizone in a micelle medium with the surfactant Triton X-100. The procedure showed a linear response ranging from 15.0 to 175.0 &micro;gL-1 Cd (R = 0.997; n = 3), detection limit of 12.5 &micro;gL-1, RSD 0.57% (n = 10) for a sample of 30 &micro;gL-1 and analytical frequency of 43 samples per hour. Recoveries between 84 and 112% were obtained with addition of Cd (II) in water samples.
287

Determinação espectrofotométrica catalítica de molibdênio e ferro explorando calibração multivariada em um sistema de análises químicas em fluxo / Catalytic spectrophotometric determination of Mo(VI) and Fe(III) exploiting multivariate calibration implemented in a flow system

Eliézer de Oliveira 30 November 2015 (has links)
Os efeitos catalíticos de Mo(VI) e Fe(III) na oxidação de iodeto por peróxido de hidrogênio foram explorados visando à determinação simultânea destes. Diferenças nas taxas de reação foram alcançadas através do estabelecimento de duas zonas reacionais distintas para alteração das cinéticas reacionais. Para isto, foi projetado um sistema de análises por injeção em fluxo que permite a inserção de duas alíquotas de amostra, sendo adicionado ácido sulfúrico em uma destas com formação de uma zona de amostra complexa. Cada elemento de fluido desta zona é caracterizado por composição química, tempo de residência e taxa de reação específicas. Os principais parâmetros que afetam a taxa reacional, tais como concentração dos reagentes, comprimento do reator e vazão total, dentre outros, foram avaliados buscando melhoria na sensibilidade e discriminação cinética entre os analitos. Os comprimentos das alças de amostragem e da bobina separadora foram avaliados construindo-se modelos matemáticos visando máxima discriminação nas previsões para os analitos. Os modelos foram construídos a partir da ferramenta quimiométrica PLS (Partial Least Squares) utilizando os dados gerados por medidas de máximos e mínimos ao longo da zona de amostra. O conjunto de calibração era composto por misturas de Mo(VI) e Fe(III) na faixa de concentrações 6,2 - 50,0 ?g L-1 e 0,5 - 7,0 mg L-1, respectivamente. O modelo selecionado apresenta boa habilidade de previsão com valores de RMSEP estimados como 0,67 ?g L-1 para Mo(VI) e 0,21 mg L-1 para Fe(III). Recuperações entre 85 e 114% foram obtidas para amostras de águas naturais. O sistema proposto apresenta estabilidade física, boa repetibilidade entre as leituras (d. p. r. < 2 %), velocidade analítica de 31 h-1 e consumo de 54 mg de iodeto de potássio e 0,30 mg de peróxido de hidrogênio por amostra / The catalytic effects of Mo(VI) and Fe(III) in the oxidation of iodide by hydrogen peroxide were exploited aiming at their simultaneous determination. Differences in reaction rates were achieved by establishing of two distinct reactions zones to modify the reaction kinetics involved. To this end, a flow injection system allowing insertion of two sample aliquots was designed, and sulfuric acid was added to one of the aliquots. A complex sample zone was then established. Each fluid element of this zone was characterized by a given chemical composition, residence time and reaction rate. The main parameters affecting the reaction rate, such as reagent concentrations, analytical path length and total flow rate, among others, were evaluated for improving sensitivity and analyte kinetic discrimination. Influences of sampling loop lengths and distance between initial plugs were studied, and mathematical models were constructed aiming at improved discrimination in prediction of analytes. The models were constructed from the PLS (Partial Least Squares) chemometric tool using data generated by measurements performed on sample zone regions with maximum and minimum local concentrations. The calibration set consisted of Mo(VI) and Fe(III) mixtures in concentration ranges of 6.2 - 50.0 ?g L-1 and 0.5 - 7.0 mg L-1, respectively. The selected model is characterized by good prediction ability prediction, as RMSEP values were estimated as 0.67 ?g L-1 for Mo(VI) and 0.21 mg L-1 for Fe(III), respectively. Recoveries within the 85 - 114% range were obtained for natural waters. The proposed system presents physical stability and favorable characteristics of measurement repeatability (r.s.d.<2%), sampling rate (31 h-1) and reagent consumption (54 mg of KI and 0.30 mg H2O2 per sample)
288

Desenvolvimento de instrumentação e procedimentos automáticos para determinação de arsênio e fluoreto em águas empregando multicomutação em fluxo e detecção fotométrica / Development of instrumentation and automatic procedures for the determination of arsenic and fluoride in waters by using flow multicommutaion and photometric detection

Marcelo Alves Teixeira 12 May 2010 (has links)
Neste trabalho, é proposto o desenvolvimento de instrumentação e procedimentos analíticos automáticos para a determinação de fluoreto e arsênio em águas empregando o conceito de multicomutação em fluxo e detecção fotométrica. Na determinação de fluoreto, o controle dos dispositivos foi realizado empregando um computador, programado em QuickBasic 4.5. O fotômetro desenvolvido utilizava um fotodetector (OPT301), uma cela de fluxo com 60 mm de caminho óptico e um LED (\'lambda\' = 525 nm), usado como fonte de radiação. Os sinais gerados pelo fotômetro foram convertidos para digital empregando um multímetro digital, que os transferia para o computador através da interface serial RS-232. O procedimento para a determinação de fluoreto foi baseado no método de zircônio/ vermelho de alizarina S, onde o fluoreto retira o zircônio da estrutura metal ligante formando um complexo incolor. Após a seleção das variáveis de controle, o procedimento proposto apresentou resposta linear na faixa de 0,25 a 1,75 mg L-1 (LD = 0,06 mg L-1), desvio relativo menor que 3,5%, freqüência de amostragem de 45 h-1. No sistema para determinação de arsênio em águas, o controle do módulo de análise foi realizado utilizando um microcontrolador da série PIC 18F2553, o qual contém um conversor A/D interno de 12 bits de resolução e capacidade de operar com taxa de amostragem de até 100.000 s-1. O mesmo recebia os parâmetros de controle por um computador via USB 2.0, que utilizava a mesma interface para transferir os dados provenientes do fotômetro. O software para essa comunicação foi escrito em Delphi 7.0 e a linguagem C foi utilizada para a programação do microcontrolador. Como sistema de detecção foi o mesmo empregado na determinação de fluoreto, utilizando um LED (\'lambda\' = 625 nm) como fonte de radiação. O procedimento proposto para a determinação de arsênio foi baseado na reação do arsênio inorgânico com boro-hidreto, onde a arsina formada reagia com azul de metileno em meio micelar. A descoloração da solução de azul de metileno era proporcional à concentração de arsênio presente na amostra. A procedimento proposto apresentou resposta linear na faixa de 2,5 a 40 \'mü\'g L-1 (r = -0,995), limite de detecção de 0,3 \'mü\'g L-1, desvio relativo menor que 6,5 %, freqüência de amostragem de 25 h-1. / The development of instrumentation and automatic procedures for the determination of arsenic and fluoride in waters by using flow multicommutation and photometric detection were proposed. For fluoride determination, the system was controlled by a microcomputer equipped with MS-Dos environment and running a software written in Quick Basic 4.5. It was used a homemade photometric detector OPT301, a 60 mm pathway flow cell, and a light emitting diode (\'lambda\' = 525 nm) as light source. Data acquisition was performed by using a digital multimeter and a microcomputer with RS- 232 serial interface. The method was based on a complexation reaction between fluoride and alizarin red S, where the fluoride takes out the zircon from the metal-binding moieties resulting in color bleaching. After optimization of parameters, the procedure provided linear response in the 0.25 to 1.75 mg L-1 range, limit of detection of 0.06 mg L- 1, coefficient of variation lower than 3.5 %, and sample throughput of 45 determinations per hour. For arsenic determination, the control module was performed by using a PIC 18F2553 microcontroller equipped with a 12 bits resolving power A/D internal converter, working at 100,000 sampling per second rate. Data acquisition was performed by a microcomputer equipped with Windows environment and running a software written in Delphi 7.0. A LED (\'lambda\' = 625 nm), as radiation source, was used for As determinations by using the same detection system used for fluoride determination. The method for As determination was based on the color bleaching of methylene blue in micellar media by AsH3 produced from inorganic As and NaBH4. The color bleaching of methylene blue was proportional to As concentration in the sample. The proposed method provided linear response in the 2.5 to 40 \'mü\'g L-1 range, limit of detection of 0,3 \'mü\'g L-1, coefficient of variation lower than 6.5 %, and sample throughput of 25 determinations per hour.
289

Desenvolvimento de uma câmara flow-batch com aquecimento direto e de procedimentos analíticos para determinação fotométrica de açúcares redutores em vinhos e de manganês em amostras vegetais / Development of a flow- batch chamber with direct heating and analytical procedures for photometric determination of reducing sugars in wine and manganese in plant samples

Marcos Augusto Stolf Brasil 27 July 2016 (has links)
Neste trabalho foi desenvolvido um sistema analítico tendo como elemento central uma câmara flow-batch com aquecimento direto e fotômetro acoplado, empregado para determinação de açúcares redutores em vinhos e de manganês em amostras vegetais. A instrumentação foi implementada utilizando o conceito flow-batch e o processo de multicomutação em fluxo. A proposta da câmara com aquecimento direto foi concebida para viabilizar procedimentos analíticos baseados em reações lentas. Adicionalmente, foi realizada a instalação do sistema de detecção fotométrica no próprio corpo da câmara, eliminando a necessidade de resfriamento e transporte da solução para outro componente para monitoramento. Esta estratégia possibilitou a redução das dimensões do sistema e o incremento na frequência de amostragem. O controle do sistema é realizado usando aplicativo desenvolvido na linguagem Visual Basic®, o qual aciona seus componentes e realiza a leitura do sinal analítico através de uma interface. Para propulsão dos fluidos é utilizada uma bomba peristáltica multicanal, ambos dispositivos foram desenvolvidos dentro do presente trabalho. Para a determinação de açúcares redutores em vinho, o método analítico adotado utiliza como reagente cromogênico o hexacianoferrato (III) de potássio em meio alcalino sob aquecimento (50 oC) e leitura em 420 nm. O sistema apresentou uma faixa de resposta linear entre 0,75 e 6% (m/v) frutose (R2= 0,999), limite de detecção de 0,14% (m/v; n = 11), desvio padrão relativo menor que 4%, e frequência analítica de 75 determinações por hora. O procedimento para a determinação de manganês foi baseado na reação de oxidação à permanganato, utilizando como agente oxidante periodato de sódio em meio ácido, aquecimento a 55 oC, e leitura em 530 nm. Após estabelecer as variáveis de controle, o sistema apresentou faixa de resposta linear entre 5 e 30 mg.L-1(R² = 0,997), limite de detecção de 2 mgL-1 (n = 11) Mn2+, desvio padrão relativo de 5%, e frequência analítica de 40 determinações por hora. A exatidão dos resultados foi avaliada aplicando o teste t-Student, onde foram comparados os resultados obtidos com os procedimentos propostos com aqueles obtidos com métodos de referência, e não foram observadas diferenças significativas ao nível de confiança de 95 % / In this work was developed an analytical system, employing a flow-batch chamber with direct heating coupled to a LED based photometer, which was tailored for the determination of reducing sugars in wine and manganese in plant samples. The instrumentation was implemented using the flow-batch concept and multicommutation flow analysis process. The proposed camera with direct heating was designed to enable analytical procedures based on slow reactions. The photometer coupling to the flow-batch chamber body, eliminated the need for a cooling step and as well as solution transportation for another component, where signal would be monitored. This strategy allowed the reduction of the system dimensions, and enabling an increase in sampling frequency. The system control was performed using software developed in Visual Basic ® language, which drove the actives components of the system. For fluid propulsion was used a multichannel peristaltic pump, which was also developed in the present work. For the determination of reducing sugars in wine, the analytical procedure was based on the reaction of potassium hexacyanoferrate (III) in an alkaline medium under heating at 50 ° C, which was monitored at 420 nm. The procedure provided a linear response ranging from 0.75 to 6.00 % (w / v) fructose (R2 = 0.999), a 0.14% limit of detection (w/v, n = 11), a relative standard deviation less than 4.0 %, and an analytical frequency of 75 determination per hour. The procedure for the determination of manganese was based on the permanganate oxidation reaction in acid medium, using sodium periodate solution as an oxidizing reagent. The flow-batch was maintained at 55 ° C, and signal was monitored at 530 nm. After establishing the control variables, the procedure provided a linear response ranging from 5.0 to 30.0 mg L-1 (R2 = 0.997), a detection of limit 2.0 mg L-1 (n = 11) Mn2+, a relative standard deviation of 5.0 % (n = 8) and an analytical frequency of 40 determination per hour. The accuracy of the results was assessed by applying the Student t-test between results obtained employing the proposed procedures and a reference method, and not significant difference at 95 % confidence level was observed
290

Modelagem e controle preditivo de um sistema de pulverização com injeção direta / Modeling and predictive control of a chemical injection sprayer system

Kleber Romero Felizardo 02 August 2013 (has links)
Sistemas de pulverização com injeção direta possibilitam o uso de diferentes agrotóxicos em uma mesma aplicação, reduzindo o desperdício de agrotóxicos e minimizando desta forma os impactos toxicológico e ambiental relacionados com o preparo e descarte da calda. Neste trabalho foram desenvolvidos modelos matemáticos para um sistema de pulverização com injeção direta de agrotóxico, incluindo a dinâmica da concentração da calda. Também foi desenvolvida uma estratégia de controle preditivo com antecipação das taxas de aplicação para ajustar as taxas de aplicação do agrotóxico e da calda. Também, uma plataforma flexível para o desenvolvimento de pulverizadores foi projetada e construída. A sua automação foi baseada em um controlador embarcado de tempo real adequado para aplicações de controle, aquisição e temporização. Para obter os parâmetros dos modelos e avaliar a estratégia de controle ensaios de vazão e concentração para diferentes pontas de pulverização foram propostos. Com o emprego da abordagem de controle preditivo, os erros das vazões do agrotóxico e da calda ficaram abaixo do nível admissível de 5%. O uso da estratégia de antecipação das taxas de aplicação permitiu aumentar a eficiência da aplicação, reduzindo em até 40% os erros de aplicação. Resultados experimentais são apresentados para validar os modelos e mostrar a eficiência da estratégia de controle desenvolvida. / Sprayer systems with direct injection allow the use of different pesticides in a single application, reducing the waste of chemicals and thereby minimizing the toxicologic and environmental risks associated with the carrier-chemical mix preparation and discard. In this work, mathematical models for a direct chemical injection sprayer system including the dynamics of the carrier-chemical mix concentration are developed. Also, a predictive control strategy with anticipative reference of application rates was developed to adjust the carrier-chemical mix and chemical flow rates. Also, a flexible platform for the development of sprayers was designed and constructed. The automation of this platform was based on a programmable automation controller suitable for control, acquisition and timming applications. To obtain the models and analyse the control strategy, essays flow and concentration for different spray nozzles were proposed. With the use of predictive control approach, the errors of the carrier-chemical mix and chemical flow rates were lower than the admissible level of 5 %. The use of the advanced references increased the efficiency of the variable rate application, reducing up to 40 % application errors. Practical results are presented to validate the models and show the efficiency of the developed control strategy.

Page generated in 0.054 seconds