• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 31
  • 21
  • 11
  • 4
  • 4
  • 3
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 94
  • 32
  • 32
  • 22
  • 13
  • 13
  • 12
  • 11
  • 10
  • 10
  • 10
  • 9
  • 9
  • 9
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Concert Hall Acoustics and Piano Lid Height: A Study of Five Arizona Concert Halls

January 2017 (has links)
abstract: Traditional consensus in duos with grand piano has been that issues of balance between piano and the other instrument can be corrected through lowering the lid on the piano, particularly when the other instrument has been thought of as less forceful. The perceived result of lowering the lid on the piano is to quiet the piano enough so as not to overwhelm the other instrument, though the physics of the piano and acoustics suggest that it is incorrect to expect this result. Due to the physics of the piano and natural laws such as the conservation of energy, as well as the intricacies of sound propagation, the author hypothesizes that lowering the lid on the piano does not have a significant effect on its sound output for the audience of a musical performance. Experimentation to determine empirically whether the lid has any significant effect on the piano's volume and tone for the audience seating area was undertaken, with equipment to objectively measure volume and tone quality produced by a mechanical set of arms that reproduces an F-major chord with consistent power. The chord was produced with a wooden frame that input consistent energy into the piano, with measurements taken from the audience seating area using a sound pressure level meter and recorded with a Zoom H4N digital recorder for analysis. The results suggested that lowering the lid has a small effect on sound pressure level, but not significant enough to overcome issues of overtone balance or individual pianists’ touch. / Dissertation/Thesis / Doctoral Dissertation Music 2017
12

Análise comparativa da reatividade anti-LID-1, NDO-LID, NDO-HSA e PGL-1 em hanseníase / Comparative analysis of the reactivity anti-LID-1, NDO-LID, NDOHSA and PGL-1 in leprosy

Fabri, Angélica da Conceição Oliveira Coelho 14 August 2015 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2018-08-21T12:03:55Z No. of bitstreams: 1 angelicadaconceicaooliveiracoelho.pdf: 3773705 bytes, checksum: e753f755e09e6a5c7102c48ac076e08f (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2018-08-21T14:22:17Z (GMT) No. of bitstreams: 1 angelicadaconceicaooliveiracoelho.pdf: 3773705 bytes, checksum: e753f755e09e6a5c7102c48ac076e08f (MD5) / Made available in DSpace on 2018-08-21T14:22:17Z (GMT). No. of bitstreams: 1 angelicadaconceicaooliveiracoelho.pdf: 3773705 bytes, checksum: e753f755e09e6a5c7102c48ac076e08f (MD5) Previous issue date: 2015-08-14 / PROQUALI (UFJF) / A infecção subclínica pode ser avaliada por meio de teste sorológico, que determina imunoglobulinas circulantes. O objetivo do presente estudo foi analisar a reatividade de diferentes antígenos em casos novos de hanseníase, contatos domiciliares de casos e em população de área endêmica, com o intuíto de identificar o melhor antígeno para o diagnóstico sorológico da hanseníase e detecção de indivíduos infectados pelo Mycobacterium leprae. Trata-se de um estudo transversal de natureza exploratória e analítica. A reatividade anti-LID1, NDO-LID, NDO-HSA e PGL-1 foi avaliada por meio do enzyme-linked immunosorbent assay. Foram analisadas amostras de sangue total em papel de filtro Whatman de 2494 indivíduos da população de sete municípios da microrregião de Almenara e de soro de 94 casos novos de hanseníase e 104 contatos domiciliares de casos residentes no município de Uberlândia. O Banco de Dados foi criado no Software Epi Info versão 3.5.1 e análise realizada no software Statistical Package for the Social Sciences for Windows 18 e no GraphPad Prism versão 5. Para análise estatística foram utilizados os seguintes testes: Kolmogorov-Smirnov, Kruskal-Wallis one-way (H), Mann-Whitney (U) com correção de Bonferroni, kappa, Spearman (rho), teste Qui-quadrado de Pearson e regressão logística binária. Foi observado maior soropositividade no grupo de casos multibacilares (MB), em contatos domiciliares de casos MB e nos indivíduos residentes nos municípios de Almenara e Jequitinhonha. Obteve-se correlação positiva entre a sorologia e o índice baciloscópico, concordância substancial e significativa no grupo de casos novos de hanseníase e correlação positiva para todos os antígenos testados. Os testes anti-LID-1 e anti-NDO-LID apresentaram melhor performance para identificar os contatos domiciliares e ou indivíduos da população infectados pelo M. leprae. O PGL-1 nativo teve maior positividade do que o NDO-HSA para todas as formas clínicas da hanseníase e no grupo de contatos domiciliares. A prevalência de soropositividade na população foi superior à taxa de detecção de casos de hanseníase em todos os municípios avaliados. A faixa etária, a renda familiar, residir em município endêmico, conhecer alguém que teve ou tem hanseníase, ter ou ter tido caso de hanseníase na familia e residir ou ter residido com caso de hanseníase são fatores que podem explicar a diferença de soropositividade anti-NDO-LID. Apenas a faixa etária e conhecer alguém que teve ou tem hanseníase é capaz de explicar a diferença de soropositividade anti-NDO-HSA. E em relação ao LID-1 nenhuma variável foi explicativa. Todos os antígenos analisados podem auxiliar na diferenciação e caracterização da hanseníase MB e na identificação de indivíduos expostos ao M. leprae, porém o NDO-LID apresentou melhor performance na identificação desses indivíduos e dos casos paucibacilares, quando comparado aos testes envolvendo os antígenos LID-1 e NDO-HSA separadamente, portanto fornece benefício adicional a esses antígenos e poderia ser utilizado como ferramenta auxiliar na vigilância epidemiológica da hanseníase. / The subclinical infection can be evaluated by serologic test which determine circulating immunoglobulins. The aim of this study was to analyze the reactivity of different antigens in leprosy cases, household contacts of index cases and the population of the endemic area to identify the best antigen for the diagnosis of leprosy and detection of individuals infected with Mycobacterium leprae. It is a cross-sectional study of exploratory and analytical nature. The reactivity anti-LID-1, NDO-LID, NDO-HAS e PGL-1 were evaluated using the enzymelinked immunosorbent assay. The whole blood in Whatman filter paper of 2494 individuals from the general population of seven municipalities in the micro-Almenara and serum of 94 patients with leprosy and 104 household contacts of patients residing in Uberlândia were analyzed. The database was created in Epi Info software version 3.5.1 and analysis in the software Statistical Package for Social Sciences for Windows 18 and GraphPad Prism version 5. For statistical analysis the following tests were used: Kolmogorov-Smirnov, Kruskal Wallis one-way (H), Mann-Whitney (U) with Bonferroni correction, kappa, Spearman (rho), chisquare test of Pearson and binary logistic regression. Identied higher seropositivity in the group of MB patients, household contacts of MB patients and in individuals living in the municipalities of Almenara and Jequitinhonha. Observed positive correlation between serology test and bacterial index, substantial agreement and significant in patients positive and positive correlation for all antigens. The LID-1 and NDO-LID antigens showed greater ability to identify household contacts or the general population infected with M. leprae, but the performance of the NDO-LID was better. The native PGL-1 had higher seropositivity than the NDO-HSA for all clinical forms of leprosy and household contacts. The seropositivity prevalence in the general population was higher than the detection rate of leprosy cases in all evaluated municipalities. The age, family income, living in a city endemic, knowing someone who had or has leprosy, had or have the case in the family and live or lived with leprosy case are factors that can explain the anti-NDO-LID seropositivity difference. Only the age range and know someone who had or has leprosy is able to explain the anti-NDO-HSA seropositivity difference. And for the LID-1 no variable explained the anti-LID-1 seropositivity difference. All serological tests analyzed can assist in the differentiation and characterization of MB leprosy and the identification of individuals exposed to M. leprae, but NDO-LID performed better in identifying these individuals and PB patients, when compared to the tests involving the LID-1 and NDO-HSA antigens separately, therefore provides additional benefit to these antigens and could be used as an auxiliary tool in epidemiological surveillance of leprosy.
13

Reclaiming Land Through Interstate Lids within the West End Community

Cieslak, Stephanie 25 May 2023 (has links)
No description available.
14

Topological Chaos and Mixing in Lid-Driven Cavities and Rectangular Channels

Chen, Jie 12 December 2008 (has links)
Fluid mixing is a challenging problem in laminar flow systems. Even in microfluidic systems, diffusion is often negligible compared to advection in the flow. The idea of chaotic advection can be applied in these systems to enhance mixing efficiency. Topological chaos can also lead to efficient and rapid mixing. In this dissertation, an approach to enhance fluid mixing in laminar flows without internal rods is demonstrated by using the idea of topological chaos. Periodic motion of three stirrers in a two-dimensional flow can lead to chaotic transport of the surrounding fluid. For certain stirrer motions, the generation of chaos is guaranteed solely by the topology of that motion and continuity of the fluid. This approach is in contrast to standard techniques. Appropriate stirrer motions are determined using the Thurston-Nielsen classification theorem, which also predicts a lower bound on the complexity of the dynamics in the flow. Work in this area has focused largely on using physical rods as stirrers, but the theorem also applies when the ``stirrers'' are passive fluid particles. In this thesis, topological chaos is theoretically and numerically investigated in lid-driven cavities and rectangular channels without internal rods. When a two-dimensional incompressible Newtonian flow is in the Stokes flow regime, the stream function satisfies the two-dimensional biharmonic equation. When the flow occurs in a lid-driven cavity with solid side walls, this equation can be solved using a method that is similar to the traditional Fourier expansion but uses an asymptotic approximation for the sum of high order terms. When the flow occurs between two infinite plates with spatially periodic boundary conditions, an exact solution in a rectangle with finite width, which represents the flow in this infinitely-wide cavity, can be obtained by using the principle of superposition. A fully developed, three-dimensional flow in a rectangular channel can be decomposed into an unperturbed Poiseuille flow in the axial direction and a lid-driven cavity secondary flow in the cross section. This model can be applied to numerically simulate either pressure-driven flow in a rectangular channel with surface grooves or electro-osmotic flow in a rectangular channel with variations in surface potential. In this dissertation, the occurrence of topological chaos in unsteady two-dimensional flows as well as steady three-dimensional flows without internal rods is demonstrated. For appropriate choices of boundary velocity on the top and/or bottom walls, there exist three periodic points in the flows that produce a chaos-generating motion. In steady flow through a three-dimensional rectangular channel, the axial direction plays the role of time and the periodic points lie on streamtubes that "braid" the surrounding fluid as it moves through the duct. When appropriate motion is applied on the boundary of the wide cavity or channel, topological chaos can also be generated in the flow. The stretching rate of non-trivial material lines in all these flows agrees with the prediction of the lower bound of topological entropy provided by the Thurston-Nielsen theorem. Ghost rod structures are found and analyzed in the lid-driven cavity and rectangular channel flows with solid side walls. The results suggest that the no-slip boundary condition on the stationary internal surfaces is one of the reasons for poor mixing in steady laminar three-dimensional flows considered previously with solid braided internal rods. / Ph. D.
15

Invento para determinação da interceptação de chuva pela serrapilheira em ecossistemas florestais / Device to measure rainfall interception by the forest litter on forest ecosystems

Rosalem, Lívia Malacarne Pinheiro 29 March 2017 (has links)
A serrapilheira é compreendida como a camada acima do solo formada a partir de materiais que caem da vegetação, funcionando como um mecanismo de interceptação da chuva. Apesar do processo de interceptação ser significativo em áreas de florestas, geralmente esse processo é subestimado ou mesmo negligenciado em modelos hidrológicos, justificado pela dificuldade na obtenção desses dados. Este projeto propôs o desenvolvimento de um equipamento que permite realizar medidas em campo da interceptação da serrapilheira em área de cerrado sensu stricto. Com o equipamento desenvolvido, LID (Litter Interception Device), são realizadas medidas do volume de água retido na serrapilheira e do volume que passa pela serrapilheira, atingindo o solo. O LID foi testado e calibrado em laboratório utilizando chuva simulada de três diferentes intensidades sobre o equipamento, contendo três quantidades diferentes de serrapilheira, 2,97, 1,45 e 0,60 kg.m-2. As amostras de serrapilheira utilizadas nos testes foram retiradas de uma área experimental de mata nativa de cerrado sensu stricto, localizada no município de Itirapina, Estado de São Paulo. As intensidades utilizadas foram definidas a partir de uma curva Intensidade-Duração-Frequência (IDF) gerada para a área experimental. Além do bom funcionamento do LID, os testes serviram para determinar os parâmetros Cmax e Cmin (capacidade máxima e capacidade mínima de armazenamento, respectivamente) da serrapilheira do cerrado sensu stricto. Os resultados mostraram que com o LID são realizadas medições da taxa de retenção de água na serrapilheira (mm.min-1), bem como de sua evaporação (mm.min-1) com precisão. Os testes para calibração do pluviógrafo revelaram que as medidas eram sempre subestimadas, necessitando utilizar uma curva de calibração (R2 = 0,99) para corrigir os registros da intensidade que passa para o pluviógrafo. Os valores encontrados para os parâmetros Cmax (1,0 a 3,07 mm) e Cmin (0,78 a 2,27 mm) corroboram com os encontrados por outros autores para a serrapilheira de diferentes florestas. Verificou-se que a variável quantidade de serrapilheira (kg) influencia mais nesses valores, do que a intensidade da chuva (mm.h-1). Conclui-se com os resultados que o LID pode ser utilizado em estudos que pretendam analisar o papel da serrapilheira em processos hidrológicos, sejam estes para a determinação da interceptação da chuva em campo, ou mesmo na determinação de parâmetros em laboratório. / Forest litter is the layer above the ground of the forest formed by materials that fall from the vegetation itself. The vegetation materials are through various stages of decomposition, functioning as a mechanism of rainfall interception. Although the interception process is significant in forested areas, this process is usually underestimated or even neglected in hydrological models due to the difficulties on obtaining these data. We proposed the development of a device that allows the field measurements of the forest litter interception in a cerrado sensu stricto area. The Litter Interception Device (LID), was tested and calibrated in the laboratory. We used simulated rainfall with three different intensities to test the device and also three different amounts of litter, 0.100, 0.230 and 0.470 kg. The litter samples used in the tests were taken from an experimental area of cerrado sensu stricto located in Itirapina, State of São Paulo, Brazil. The intensities of simulated rainfall were obtained from an Intensity-Duration-Frequency (IDF) curve made for the experimental area. Besides the LID functioning tests, the device was tested to determine the parameters Cmax and Cmin (maximum capacity and minimum storage capacity, respectively) of the cerrado sensu stricto forest litter. The results showed that the LID allows measurements of the volume of water retained in the forest litter (mm.min-1) as well as its evaporation (mm.min-1). The pluviometer calibration tests revealed that the measurements were always underestimated, requiring a calibration curve (R2 = 0.99) to correct the volume records that flow to the tipping bucket pluviometer. The values found for Cmax (1.0 - 3.07 mm) and Cmin (0.78 - 2.27 mm) are according with those found by other authors for different kinds of forest litters. It was verified that the variation in the amount of forest litter (kg) influenced more in these values, than the rainfall intensity (mm.min-1) . We concluded that the LID can be used in studies that intend to analyze the role of the forest litter in hydrological processes, whether they area for the determination of the interception of rain in the field or even and in laboratory studies to determine interception parameters of forest litter.
16

Development of a system of acquisition and movement analysis : application on Parkinson's disease / Développement d’un système d’acquisition et d’analyse du mouvement : application à la maladie de Parkinson

Jalloul, Nahed 12 December 2016 (has links)
Le travail présenté dans ce mémoire porte sur le développement d'un système de surveillance ambulatoire pour la détection de la dyskinésie induite par la Levodopa (LID) chez les patients de la maladie de Parkinson (PD). Le système est composé d’unités de mesure inertielle (IMUs) qui recueillent des signaux de mouvement chez des sujets sains et des patients parkinsoniens. Des méthodes différentes sont évaluées pour la détection de LID avec et sans classification des activités. Les données recueillies auprès des sujets sains sont utilisées pour concevoir un classificateur d'activité fiable. Par la suite, un algorithme qui effectue la classification des activités et la détection de la dyskinésie sur les données recueillies auprès de des patients parkinsoniens est proposé. Une nouvelle approche basée sur l'analyse de réseau complexe est également explorée et présente des résultats intéressants. Les méthodes de traitement développées ont été intégrées dans une plateforme complète d’analyse nommée PARADYSE. / The work presented in this thesis is concerned with the development of an ambulatory monitoring system for the detection of Levodopa Induced Dyskinesia (LID) in Parkinson’s disease (PD) patients. The system is composed of Inertial Measurement Units (IMUs) that collect movement signals from healthy individuals and PD patients. Different methods are evaluated which consist of LID detection with and without activity classification. Data collected from healthy individuals is used to design a reliable activity classifier. Following that, an algorithm that performs activity classification and dyskinesia detection on data collected from PD patients is tested. A new approach based on complex network analysis is also explored and presents interesting results. The evaluated analysis methods are incorporated into a platform PARADYSE in order to further advance the system’s capabilities.
17

Perfil sorológico à LID-1 e PGL-I em pacientes com reação hansênica tipo I e tipo II e em pacientes não reacionais / Leprosy: serologic reactivity to LID-1 and PGL-i antigens in patients with type I , type II reactions and unreactional patients

Mizoguti, Danielle de Freitas 21 February 2014 (has links)
Submitted by Luciana Ferreira (lucgeral@gmail.com) on 2016-02-01T08:34:02Z No. of bitstreams: 2 Dissertação - Danielle de Freitas Mizoguti - 2013.pdf: 1318732 bytes, checksum: 8084d20c2bec9e4264a71581ca4d04b2 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2016-02-01T08:37:28Z (GMT) No. of bitstreams: 2 Dissertação - Danielle de Freitas Mizoguti - 2013.pdf: 1318732 bytes, checksum: 8084d20c2bec9e4264a71581ca4d04b2 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2016-02-01T08:37:28Z (GMT). No. of bitstreams: 2 Dissertação - Danielle de Freitas Mizoguti - 2013.pdf: 1318732 bytes, checksum: 8084d20c2bec9e4264a71581ca4d04b2 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2014-02-21 / Introduction: Leprosy Type 1 ( T1R) and type 2 reactions ( T2R) are considered the major complicators in the clinical management of leprosy patients. Leprosy reactions can occur before, during or after multidrug therapy (MDT). T1R is associated with exacerbated Th1 type cell mediated immunity (CMI) whereas T2R is associated with Th2 type immunity characterized by strong antibody production and in some cases transitory CMI to M. leprae antigens. Objective: Assess the serological reactivity to LID-1 fusion protein and to PGL-I M. leprae antigens among multibacillary (MB), paucibacillary (PB) leprosy patients that developed reaction at diagnosis or during MDT compared to reaction free MB and PB patients. Material and Methods: Paired serum samples from 73 leprosy patients were tested by ELISA to detect IgG antibodies to LID-1 and IgM responses to PGL-I. Leprosy patients included MB that developed T1R or T2R at diagnosis or during MDT and PB patients that developed T1R at diagnosis or during MDT compared to reaction free MB and PB patients. For T1R and T2R patients, samples collected during reactions and in the absence of reactions were tested and for reaction free patients samples collected at diagnosis and after MDT were tested. Results: The decline of anti LID-1 and anti PGL-I antibodies levels was significant among MB patients with T1R at diagnosis (p <0,05). Among MB patients with T2R at diagnosis and non reactional MB leprosy patients, the decline of antibodies was significant only to LID-1 (p <0,05). Higher levels of anti LID-1 antibodies were observed in MB patients who developed T2R at diagnosis compared with unreactional patients (p = 0.020) and patients who developed T1R at diagnosis (p = 0.008). Moreover, different antibody levels were seen in patients who developed T2R during MDT compared with unreactional MB patients after MDT (p = 0.020). Conclusions: Our data suggest that high anti LID-1 antibody levels may be associated with higher risk of T2R in MB patients. / Introdução: As reações hansênicas (tipo 1/RT1 e tipo 2/RT2) são as principais complicações no manejo clínico de pacientes com hanseníase e podem ocorrer antes, durante e após multidrogaterapia (MDT). A RT1 está associada a exacerbação da imunidade mediada por células (CMI) do tipo Th1 para antígenos do Mycobacterium leprae. Já a RT2 está associada com a resposta imunitária do tipo Th2, caracterizada por forte produção de anticorpos e em alguns casos ativação transitória da CMI. Objetivo: Avaliar a reatividade sorológica a proteína de fusão LID-1 e ao PGL-I do M. leprae em pacientes com hanseníase multibacilares (MB) e paucibacilares (PB) com reação hansênica e em pacientes MB e PB que não desenvolveram reação. Materiais e Métodos: Foram testadas amostras um total de 73 pacientes com hanseníase MB que desenvolveram RT1 ou RT2 ao diagnóstico ou durante MDT e em pacientes PB que desenvolveram RT1 ao diagnóstico ou durante MDT comparados com pacientes MB e PB que não desenvolveram reação hansênica ao diagnóstico nem durante MDT. A presença de IgG anti LID-1 e IgM anti PGL-I foi testada por ELISA. Resultados: O declínio dos níveis de anticorpos anti LID-1 e anti PGL-I foi significativo dentre os pacientes MB que estavam em RT1 ao diagnóstico (p< 0.05). Dentre os pacientes MB que estavam em RT2 ao diagnóstico e pacientes MB não reacionais, o declínio dos anticorpos foi significante apenas para LID-1 (p< 0.05). Níveis mais altos de anticorpos anti LID-1 foram observados nos pacientes MB que desenvolveram RT2 ao diagnóstico quando comparados com pacientes MB que desenvolveram RT1 ao diagnóstico (p=0.008) ou pacientes MB não reacionais (p=0.020). Pacientes MB que desenvolveram RT2 durante a MDT também apresentaram níveis mais altos de anticorpos anti LID-1 comparados com pacientes MB não reacionais após MDT (p=0.020). Conclusões: Nossos resultados sugerem que altos níveis de anticorpos anti LID-1 podem estar associados ao maior risco de desenvolvimento de RT2 em pacientes MB.
18

Invento para determinação da interceptação de chuva pela serrapilheira em ecossistemas florestais / Device to measure rainfall interception by the forest litter on forest ecosystems

Lívia Malacarne Pinheiro Rosalem 29 March 2017 (has links)
A serrapilheira é compreendida como a camada acima do solo formada a partir de materiais que caem da vegetação, funcionando como um mecanismo de interceptação da chuva. Apesar do processo de interceptação ser significativo em áreas de florestas, geralmente esse processo é subestimado ou mesmo negligenciado em modelos hidrológicos, justificado pela dificuldade na obtenção desses dados. Este projeto propôs o desenvolvimento de um equipamento que permite realizar medidas em campo da interceptação da serrapilheira em área de cerrado sensu stricto. Com o equipamento desenvolvido, LID (Litter Interception Device), são realizadas medidas do volume de água retido na serrapilheira e do volume que passa pela serrapilheira, atingindo o solo. O LID foi testado e calibrado em laboratório utilizando chuva simulada de três diferentes intensidades sobre o equipamento, contendo três quantidades diferentes de serrapilheira, 2,97, 1,45 e 0,60 kg.m-2. As amostras de serrapilheira utilizadas nos testes foram retiradas de uma área experimental de mata nativa de cerrado sensu stricto, localizada no município de Itirapina, Estado de São Paulo. As intensidades utilizadas foram definidas a partir de uma curva Intensidade-Duração-Frequência (IDF) gerada para a área experimental. Além do bom funcionamento do LID, os testes serviram para determinar os parâmetros Cmax e Cmin (capacidade máxima e capacidade mínima de armazenamento, respectivamente) da serrapilheira do cerrado sensu stricto. Os resultados mostraram que com o LID são realizadas medições da taxa de retenção de água na serrapilheira (mm.min-1), bem como de sua evaporação (mm.min-1) com precisão. Os testes para calibração do pluviógrafo revelaram que as medidas eram sempre subestimadas, necessitando utilizar uma curva de calibração (R2 = 0,99) para corrigir os registros da intensidade que passa para o pluviógrafo. Os valores encontrados para os parâmetros Cmax (1,0 a 3,07 mm) e Cmin (0,78 a 2,27 mm) corroboram com os encontrados por outros autores para a serrapilheira de diferentes florestas. Verificou-se que a variável quantidade de serrapilheira (kg) influencia mais nesses valores, do que a intensidade da chuva (mm.h-1). Conclui-se com os resultados que o LID pode ser utilizado em estudos que pretendam analisar o papel da serrapilheira em processos hidrológicos, sejam estes para a determinação da interceptação da chuva em campo, ou mesmo na determinação de parâmetros em laboratório. / Forest litter is the layer above the ground of the forest formed by materials that fall from the vegetation itself. The vegetation materials are through various stages of decomposition, functioning as a mechanism of rainfall interception. Although the interception process is significant in forested areas, this process is usually underestimated or even neglected in hydrological models due to the difficulties on obtaining these data. We proposed the development of a device that allows the field measurements of the forest litter interception in a cerrado sensu stricto area. The Litter Interception Device (LID), was tested and calibrated in the laboratory. We used simulated rainfall with three different intensities to test the device and also three different amounts of litter, 0.100, 0.230 and 0.470 kg. The litter samples used in the tests were taken from an experimental area of cerrado sensu stricto located in Itirapina, State of São Paulo, Brazil. The intensities of simulated rainfall were obtained from an Intensity-Duration-Frequency (IDF) curve made for the experimental area. Besides the LID functioning tests, the device was tested to determine the parameters Cmax and Cmin (maximum capacity and minimum storage capacity, respectively) of the cerrado sensu stricto forest litter. The results showed that the LID allows measurements of the volume of water retained in the forest litter (mm.min-1) as well as its evaporation (mm.min-1). The pluviometer calibration tests revealed that the measurements were always underestimated, requiring a calibration curve (R2 = 0.99) to correct the volume records that flow to the tipping bucket pluviometer. The values found for Cmax (1.0 - 3.07 mm) and Cmin (0.78 - 2.27 mm) are according with those found by other authors for different kinds of forest litters. It was verified that the variation in the amount of forest litter (kg) influenced more in these values, than the rainfall intensity (mm.min-1) . We concluded that the LID can be used in studies that intend to analyze the role of the forest litter in hydrological processes, whether they area for the determination of the interception of rain in the field or even and in laboratory studies to determine interception parameters of forest litter.
19

Efeito da suspensão frontal com fáscia muscular na cinemática palpebral / The effect of frontalis slings with muscular fascia in the eyelid\'s kinematics

Baccega, Adriano Antonio 18 May 2018 (has links)
O objetivo do estudo foi avaliar parâmetros da cinemática palpebral durante o piscar espontâneo e movimentos sacádicos palpebrais em pacientes com ptose congênita submetidos à correção cirúrgica pela técnica de suspensão frontal com fáscia muscular. Com um sistema de câmeras de captação infravermelha para análise tridimensional de movimentos foi feito registro simultâneo de movimentos de supercílio e de pálpebra. Para análise do piscar espontâneo foram avaliados 17 pacientes com ptose congênita que realizaram correção cirúrgica pela técnica de suspensão frontal com utilização de fáscia muscular autógena (n=14), e fáscia lata preservada (n=3), e para o estudo do movimento sacádico palpebral, a avaliação foi dos 14 pacientes que utilizaram apenas fáscia autógena. Um grupo controle com 17 indivíduos normais também foi medido. Para análise do piscar espontâneo um programa foi utilizado para medidas de amplitude e velocidade máxima de movimento durante a observação de um filme comercial por 5 minutos. Para análise do movimento sacádico palpebral foram realizadas medidas em 10, 20, 30, 40 e 50 graus do olhar para baixo. A avaliação da superfície ocular em lâmpada de fenda com utilização de fluoresceína foi realizada nos pacientes que apresentavam ou não lagoftalmo. O número de piscadelas foi significativamente diminuído nos pacientes. A distribuição do intervalo entre as piscadelas foi similar nos dois grupos. A média de amplitude da fase descendente do piscar dos pacientes foi apenas 38% da média do grupo controle. A inclinação da reta da \"main sequence\" para o piscar espontâneo para os pacientes foi mais baixa. Nos controles o movimento do supercilio foi muito pequeno e insignificante durante o piscar espontâneo. Nos pacientes, a média de amplitude do movimento do supercílio foi cinco vezes maior que nos controles chegando a 45% da amplitude do piscar. Os movimentos sacádicos palpebrais mostraram uma importante restrição e não aumentou além de 30 graus do olhar para baixo. A velocidade máxima da pequena amplitude dos movimentos sacádicos palpebral foi muito baixa. Enquanto a movimentação do supercilio no grupo controle ficou entre 3,3 e 9,3% do movimento sacadico palpebral, nos pacientes a movimentação do supercílio foi responsável por 43,5 a 57,4% do movimento palpebral. Lagoftalmo foi encontrado em 13 (76,5%) dos pacientes. Apenas 3 (23%) mostraram sinais de ceratopatia superficial inferior, apesar da presença do fenômeno de Bell. A amplitude e velocidade do piscar espontâneo está severamente diminuída em pacientes com suspensão frontal com fáscia muscular. Esse tipo de material causa um efeito restritivo permanente nas propriedades elásticas das pálpebras. Após a cirurgia a amplitude do piscar é dependente da amplitude do movimento do supercílio. O lagoftalmo é uma consequência natural da suspensão frontal com fáscia muscular. / The purpose of the present investigation was to measure lid kinematics parameters in spontaneous blink metrics and downward eyelid saccadic movements in patients with congenital ptosis operated with frontalis slings with muscles fascia. A optoeletronic system was employed with infrared 3-dimensional video motion analyzer to simultaneously measure brow motion and spontaneous blinks in 17 patients with congenital ptosis who underwent frontalis sling with autogeneous muscle fascia (n=14) and banked fascia lata (n=3). Downward eyelid saccadic movements were analyzed only in the 14 patients with autogeneous muscle fascia. A control group of equal number of healthy subjects was also measured. For analyses of spontaneous blinks, a customized software identified and quantified the amplitude and maximum velocity during 5 minutes observation of a commercial movie. For downward eyelid saccadic movements, 10, 20, 30, 40 and 50 degrees of downgaze were measure. The corneal status of the patients with and without lagophthalmos was evaluated with slit lamp biomicroscopy with fluorescein staining. Blink rate was significantly diminished in the patients. The distribution of interblink time was similar in both groups. The mean amplitude of the down phase of the patients\' blinks was only 38% of the controls. The main sequence slope of the patients´ blinks was abnormally low. In controls brow motion was a minute and random event no related to blinks. In the patients, the means brow amplitude was 5 times higher than in controls reaching 45% of the blink amplitude. The lid saccades of the patients were severely restricted and did not increase beyond 30 degrees of downgaze. The maximum velocity of the small amplitude lid saccades was also abnormally low. While in controls brow motion accounted for about 3,3 to 9,3% of the lid saccades, in the patients brow motion was responsible for more than 43,5% to 57,4% lid movements. Lagophthalmos was detected on 13 (76,5%) patients. Out of these 3 (23%) showed signs of inferior superficial keratopathy despite the presence of normal. Spontaneous blink amplitude and velocity are severely impaired in patients with fascia slings. This material has a permanent restrictive effect on the elastic properties of the lids. After surgery blinking amplitude is linearly related to the amplitude of brow motion. Postoperative lagophthalmos is a natural consequence of the slings with muscle fascia.
20

Aplicação do modelo hidrológico SWMM na gestão das águas pluviais urbanas: estudo de caso da bacia hidrográfica do Rio Morto, Rio de Janeiro. / Application of hydrological model SWMM on urban stormwater management: a case study of the Rio Morto basin, Rio de Janeiro.

Daniele Pereira Batista Amaral 11 April 2014 (has links)
O crescimento da população e dos núcleos urbanos durante o século XX, sobretudo nos países em desenvolvimento, contribuiu para o aumento das áreas impermeáveis das bacias hidrográficas, com impactos importantes nos sistemas de drenagem urbana e na ocorrência de enchentes associadas. As enchentes trazem prejuízos materiais, na saúde e sociais. Recentemente, têm sido propostas práticas conservacionistas e medidas compensatórias, que buscam contribuir para o controle das enchentes urbanas, através do retardo do pico e amortecimento dos hidrogramas. Modelos matemáticos hidrológicos-hidráulicos permitem a simulação da adoção destas medidas de controle, demonstrando e otimizando sua localização. Esta dissertação apresenta os resultados da aplicação do modelo hidrológico Storm Water Management Model (SWMM) à bacia hidrográfica de estudo e representativa do rio Morto localizada em área peri-urbana em Jacarepaguá na cidade do Rio de Janeiro, com área de 9,41 km. O processamento do modelo SWMM foi realizado com o apoio da interface Storm and Sanitary Analysis (SSA), integrada ao sistema AutoCAD Civil 3D. Além da verificação da adequabilidade do modelo à representação dos sistemas hidrológico e hidráulico na bacia, foram desenvolvidos estudos para dois cenários como medidas de controle de enchentes: cenário 1, envolvendo implantação de um reservatório de detenção e, cenário 2, considerando a implantação de reservatórios de águas pluviais nos lotes. Os hidrogramas resultantes foram comparados ao hidrograma resultante da simulação nas condições atuais. Além disso, foram avaliados os custos associados a cada um dos cenários usando o sistema de orçamento da Empresa Rio Águas da PCRJ. Nas simulações foram adotadas a base cartográfica, e os dados climatológicos e hidrológicos previamente observados no contexto do projeto HIDROCIDADES, Rede de Pesquisa BRUM/FINEP, na qual este estudo se insere. Foram representados os processos de geração e propagação do escoamento superficial e de base. Durante o processo de calibração, realizou-se a análise de sensibilidade dos parâmetros, resultando como parâmetros mais sensíveis os relativos às áreas impermeáveis, especialmente o percentual de área impermeável da bacia (Ai). A calibração foi realizada através do ajuste manual de sete parâmetros do escoamento superficial e cinco do escoamento de base para três eventos. Foram obtidos coeficientes de determinação entre 0,52 e 0,64, e a diferença entre os volumes escoados e observados entre 0,60% e 4,96%. Para a validação do modelo foi adotado um evento pluviométrico excepcional observado na cidade em abril de 2010, que à época causou enchentes e grandes transtornos na cidade. Neste caso, o coeficiente de determinação foi igual a 0,78 e a diferença entre volumes foi de 15%. As principais distorções entre hidrogramas observados e simulados foram verificados para as vazões máximas. Em ambos os cenários as enchentes foram controladas. A partir destes estudos, pôde-se concluir que o melhor custo-benefício foi o cenário 2. Para este cenário, foi observado maiores amortecimento e retardo da vazão de pico do hidrograma, igual a 21,51% da vazão simulada para as condições atuais da bacia. Os custos de implantação orçados para os reservatórios de lote ficaram 52% a menos do que o do reservatório de detenção. / Population and urban occupation growth during 20th century, mainly in underdeveloped countries, contributed for increasing impermeable surfaces in drainage basins, leading to important impacts on urban drainage systems and associated floods. Floods cause material losses, healthy and social problems, apart of great disruptions in large citys mobility. Recently, a number of, non-conventional, conservative practices and compensatory measurements have been proposed seeking urban flood control, by lengthening hydrographs time lag and promoting shallow rising limb. Hydrologic-hydraulic mathematical models allow the simulation of these flood control measurements, demonstrating and optimizing their location, maximizing the benefits of their application. This dissertation presents the results of the application of the Storm Water Management Model (SWMM) to the representative and under study catchment of Morto River, with 9,41 km2 of area, located in a peri urban area, in Jacarepaguá, city of Rio de Janeiro, Brazil. Storm and Sanitary Analysis (SSA) tool integrated to AutoCAD Civil 3D System supported the model processing. Apart of verifying the representativeness of the hydrologic-hydraulic modelling system to the physical processes in the Morto river catchment, two different scenarios were studied as means of flood control: scenario 1, involving the simulation of one retention reservoir and, scenario 2, involving the use of multiple distributed rainwater reservoirs in the lots. The resulting hydrographs were compared to the one for catchments actual conditions. Additionally, the associated costs for each scenario were evaluated applying the official budget system of Rio Águas of Rio de Janeiro Council. It was applied the cartographic data base, climatological and hydrological data obtained in the HIDROCIDADES Project, FINEP BRUM Research Network, under which this work has been developed. The processes of generation and propagation of runoff and baseflow were modelled. During the calibration process, was performed a sensitivity analysis of the parameters, resulting as the most sensitive parameters those related to impervious areas, especially the percentage of impervious area in the basin (Ai). Manually calibration was performed, seven parameters for runoff simulation and five for baseflow were adjusted, for three events, presenting values for the coefficient of determination between 0.52 and 0.64. The difference between simulated and observed volumes varied from 0.60% to 4.96 %. Model validation was performed for an exceptional rainfall event in April 2010, which caused floods in many places in the city. In this case, the coefficient of determination was equal to 0.78 and difference in runoff volumes equal to 15 %, being identified that the main differences are in peak flows discharges. In both scenarios floods were totally controlled. It was concluded that the best cost-benefit was for scenario 2. For this scenario it was observed the best result, considering both reduction on hydrographs peak flow discharge and increasing on time to peak. Peak flow discharge was reduced by 21,51% when compared to the simulated hydrograph for catchments current stage. It was found a much lower cost for scenario 2, the budget was 52% less than the budget for scenario 1.

Page generated in 0.0461 seconds