• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 183
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 187
  • 136
  • 117
  • 70
  • 42
  • 41
  • 40
  • 37
  • 37
  • 37
  • 34
  • 26
  • 25
  • 22
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Amamentar com fissuras mamárias: significado para primíparas

Moreira, Michelle Araújo January 2006 (has links)
119f. / Submitted by Suelen Reis (suziy.ellen@gmail.com) on 2013-04-04T11:43:01Z No. of bitstreams: 1 michelle%20moreira.pdf: 2342001 bytes, checksum: 944e84d72b8631c02a7df196044f3634 (MD5) / Approved for entry into archive by Rodrigo Meirelles(rodrigomei@ufba.br) on 2013-04-09T17:38:51Z (GMT) No. of bitstreams: 1 michelle%20moreira.pdf: 2342001 bytes, checksum: 944e84d72b8631c02a7df196044f3634 (MD5) / Made available in DSpace on 2013-04-09T17:38:51Z (GMT). No. of bitstreams: 1 michelle%20moreira.pdf: 2342001 bytes, checksum: 944e84d72b8631c02a7df196044f3634 (MD5) Previous issue date: 2006 / A amamentação é um processo complexo que incorpora valores sociais, culturais, econômicos e políticos, mas se faz necessário considerar o ser-mulher-primípara como ser decisório, valorizando sua vivência. Os programas de Incentivo à Amamentação, no Brasil, enfatizam aspectos biologicistas, apesar das novas estratégias criadas, a exemplo do aconselhamento em amamentação, favorecendo a assistência humanizada, valorizando a mulher como núcleo do processo e, portanto, capaz de optar pela permanência ou substituição da amamentação, na vivência das fissuras. Minha experiência profissional, atrelada à vivência pessoal e singular, no processo do amamentar com fissuras, deu origem a este estudo fenomenológico, momento em que defini como objeto o significado da amamentação para primíparas que vivenciaram fissuras mamárias e que amamentaram, tendo como objetivo compreender o significado que primíparas atribuem à manutenção da amamentação, tendo vivenciado fissuras mamárias. O referencial teórico-filosófico teve como pilar as idéias do filósofo Martin Heidegger, expressas na obra Ser e Tempo. A entrevista fenomenológica, ocorrida em janeiro de 2006, foi realizada no domicílio de oito primíparas, que vivenciaram fissuras e que amamentaram. As questões norteadoras foram as seguintes: Como foi para você amamentar, tendo fissuras mamárias? Como você se sentiu amamentando nessa situação? À luz dos conceitos heideggerianos, caminhei para a interpretação compreensiva, momento em que percebi que o significado da amamentação, atribuído pelas primíparas, na vivência das fissuras mamárias, baseado no modo existencial de ser-com, foi desvelado pelos modos de ser da pre-sença, do ser-aí. Assim sendo, surgiram: a facticidade, a ocupação, a transcendência, a de-cadência, o temor, o cuidado, a existência inautêntica, a fuga, a angústia, o falatório, a curiosidade, a ambigüidade, a solicitude e a temporalidade. Percebi a tristeza diante do aparecimento da fissura, demonstrando impotência por parte da mulher em resolver tal patologia, a felicidade pela continuidade na prática do amamentar, apesar da vivência de dor, desconforto, perpetuando o mito do amor materno, a manutenção da amamentação em benefício da (o) filha (o), o apoio ambíguo por parte da família, cônjuge, outras nutrizes e equipe multidisciplinar, o desejo velado pela suspensão de amamentar, decorrente da pressão social, o valor nutricional do leite materno e, conseqüentemente, o adequado desenvolvimento nutricional da (o) filha (o), atuando como compensadores pela manutenção da amamentação, a tentativa de suspensão justificada pela ausência de leite materno e/ ou rejeição do seio pela criança, o desconhecimento dos cuidados com a mama, posição e pega corretas no momento do amamentar. O estudo contribuirá para que familiares e profissionais assistam o ser-mulherprimípara na vivência das fissuras, compreendendo-a como ser único, refletindo sobre as ações executadas, entendendo a mulher no seu possível. O processo do amamentar com fissuras mamárias, vivenciado pelo ser-primípara, constitui-se numa prática que envolve um componente biológico e que ultrapassa as dimensões do físico, em busca do significado atribuído pelo seu ser, baseado no modo existencial do cotidiano. / Salvador
22

Estudo preliminar da farmacocinética da doxorrubicina e avaliação do ajuste de dose em mulheres com cancêr de mama / Preliminary investigation of the pharmacokinetics of doxorubicin and evaluation of dose adjustment in women with breast cancer

Barpe, Deise Raquel January 2009 (has links)
Objetivos: Simular um ajuste de dose em pacientes com sobrepeso e com obesidade que utilizam a doxorrubicina (DOX), que proporcione curvas de concentração plasmática e concentrações máximas (Cmáx) semelhantes às de pacientes com peso normal. Metodologia: Determinou-se as concentrações plasmáticas de DOX em pacientes com câncer de mama após a administração i.v. de 60 mg/m2, com ajuste de dose pelo BSA e com tempo de infusão de 40 minutos (0,66 h). As pacientes foram divididas em três grupos: a) pacientes com peso normal (IMC até 24,9) (n = 3); b) pacientes com sobrepeso (IMC 25,0 – 29,9) (n = 5); c) pacientes com obesidade (IMC acima 30,0) (n = 2). Os tempos de coleta utilizados foram: 0,66, 1,66, 8,66, e 24,66 h. Os perfis farmacocinéticos da DOX foram avaliados após quantificação da DOX através de metodologia por CLAE desenvolvida e validada. Resultados e Discussão: Os parâmetros farmacocinéticos ASC e Cmáx foram analisados por abordagem não-compartimental e compartimental. Em ambas as análises encontraram-se diferenças significativas (α = 0,05) entre os grupos com sobrepeso e com obesidade comparados com o grupo com peso normal para ASC e diferenças significativas entre o grupo com sobrepeso comparado ao grupo de pacientes com peso normal para o Cmáx. Após simulação de ajuste de dose pelo peso e pelo IMC, para as pacientes com sobrepeso e obesas, obtivemos novos valores de ASC e Cmáx. Houve diferenças significativas (α = 0,05) para o grupo de pacientes com sobrepeso comparado ao grupo com peso normal para a ASC e nenhuma diferença significativa entre os grupos estudados para Cmáx. Os percentuais de diferença da ASC e Cmáx do grupo das pacientes com sobrepeso e obesas comparados com o grupo de pacientes com peso normal foram diminuindo quando a dose era ajustada pelo peso e IMC. Conclusões: O ajuste de dose pelo índice BSA, comumente usado na prática clínica, não produz concentrações plasmáticas iguais em grupos de pacientes com peso normal e com sobrepeso, indicando que outros índices devem ser considerados, como peso e IMC. / Objectives: to simulate a dose adjustment in patients with overweight and obesity using doxorrubicin (DOX), providing plasma concentrations similar to those of patients with normal weight. Methodology: plasma concentrations of DOX were determined in patients with breast cancer after the iv. administration of 60 mg/m2 of DOX, adjusted by the BSA and with an infusion time of 40 minutes (0.66 h). The patients were divided into three groups: (a) patients with normal weight (BMI < 24.9) (n = 3); b) patients with overweight (BMI 25.0 – 29,9) (n = 5); c) patients obese (BMI > 30.0) (n = 2). Samples were collected at 0.66, 1.66, 8.66, and 24,66 h. DOX's pharmacokinetic profiles were evaluated after quantification of DOX using a new HPLC method developed and validated. Results and discussion: pharmacokinetic parameters (AUC and Cmax) were analyzed by non-compartmental and compartmental approaches. Significant differences (α = 0.05) between overweight and obese groups when compared with the normal weight group were found with respect to AUC and significant difference between the group with overweight compared to the patients with normal weight was found for Cmax. After simulating the dose adjustment by weight and by BMI for overweight and obese patients, new values for Cmax ASC were calculated. The new values obtained using both weight and BMI were closer to the normal group than those obtained with the BSA. The percentage of difference of ASC and Cmax of the overweight and obese group compared with the Group of patients with normal weight were lower when the dose was adjusted by weight and IMC. Conclusions: dose adjustment index BSA, commonly used in clinical practice, produced different plasma concentrations in groups of patients with normal weight, overweight, and obese, indicating that other indexes must be considered, such as weight and BMI.
23

Avaliação de próteses mamárias quanto às características macroscópicas e resistência à tração.

FONSECA, Letícia Seixas Prata da. 09 July 2018 (has links)
Submitted by Maria Medeiros (maria.dilva1@ufcg.edu.br) on 2018-07-09T15:49:08Z No. of bitstreams: 1 LETÍCIA SEIXAS PRATA DA FONSECA - DISSERTAÇÃO (PPGCEMat) 2015.pdf: 1243293 bytes, checksum: 891b96b492cd9c5893bfc592ad82f05e (MD5) / Made available in DSpace on 2018-07-09T15:49:08Z (GMT). No. of bitstreams: 1 LETÍCIA SEIXAS PRATA DA FONSECA - DISSERTAÇÃO (PPGCEMat) 2015.pdf: 1243293 bytes, checksum: 891b96b492cd9c5893bfc592ad82f05e (MD5) Previous issue date: 2015-02-06 / Após alerta sanitário emitido pela Agencia Francesa de Segurança Sanitária de Produtos de Saúde (AFFSAPS) de não conformidades no silicone utilizado para fabricação de próteses mamárias da empresa Poly Implant Prothese (PIP), a Agência Nacional de Vigilância Sanitária (ANVISA) publicou regulamentação estabelecendo a necessidade de certificação no âmbito do Sistema Brasileiro de Avaliação da Conformidade (SBAC) segundo parâmetros de Portaria do Instituto Nacional de Metrologia, Qualidade e Tecnologia (INMETRO) para avaliação de conformidade para Implantes Mamários. Dentre outros requisitos foi estabelecida a obrigatoriedade de observação das condições descritas na referida portaria. Neste trabalho foram avaliadas amostras de próteses mamárias de silicone de um mesmo fabricante, com as mesmas especificações, variando apenas o número dos lotes. Observaram-se as características macroscópicas das amostras como variáveis para a realização de ensaios normatizados. Foram comparadas características das amostras como rugosidade, cor, consistência, deformação, aderência ao elastômero, adesividade do gel e comportamento mecânico das membranas quando submetidas ao ensaio de tração. Embora tenham sido avaliadas próteses com as mesmas especificações de fabrica, foram observadas diferenças nas características macroscópicas das amostras e na resistência à tração. Quando avaliados em conjunto, os dados demonstram discrepâncias nas características das amostras e inconformidades com as normas estabelecidas. / After health alert issued by the French Agency for Sanitary Safety of Health Products (AFFSAPS) of non-compliance in the silicone used for the manufacture of breast implants the company Poly Implant Prothese (PIP), the Brazilian Health Surveillance Agency (ANVISA) has published regulations establishing certification requirement under the Brazilian System of Conformity Assessment (SBAC) within the parameters of Ordinance of the National Institute of Metrology, Quality and Technology (Inmetro) for conformity assessment to Breast Implants. Among other requirements the obligation to observe the conditions described in the said ordinance was established. In this work we were evaluated samples of silicone breast implants from the same manufacturer with the same specifications, varying only the number of lots. Were observed in the macroscopic characteristics of the samples as variable for performing standardized tests. Sample characteristics were compared as roughness, color, consistency, deformation, adhesion to the elastomer, gel adhesive and mechanical behavior of the membrane when subjected to tensile test. Although dentures have been evaluated with the same specifications of manufactures, differences were observed in macroscopic characteristics of the samples and tensile strength. When evaluated together, the data show differences in the characteristics of samples and noncompliance with established standards.
24

Avaliação das propriedades física, química e biológicas de próteses mamárias de silicone explantadas.

SERAFIM FILHO, Péricles Vitório. 10 July 2018 (has links)
Submitted by Maria Medeiros (maria.dilva1@ufcg.edu.br) on 2018-07-10T12:32:58Z No. of bitstreams: 1 PÉRICLES VITÓRIO SERAFIM FILHO - DISSERTAÇÃO (PPGCEMat) 2015.pdf: 2732272 bytes, checksum: f9246e9f76ba0abd4b6bbc275b9d09c4 (MD5) / Made available in DSpace on 2018-07-10T12:32:58Z (GMT). No. of bitstreams: 1 PÉRICLES VITÓRIO SERAFIM FILHO - DISSERTAÇÃO (PPGCEMat) 2015.pdf: 2732272 bytes, checksum: f9246e9f76ba0abd4b6bbc275b9d09c4 (MD5) Previous issue date: 2015-08-31 / Os implantes mamários caracterizam-se como dispositivos médicos que são usados para aumentar o tamanho dos seios ou para reconstruir a mama após mastectomia ou corrigir uma anomalia congênita. Sabe-se que desvio no processo produtivo de implantes mamários e o tempo de uso podem reduzir as propriedades do produto final e favorecer risco de agravos à saúde da população. Desta forma, este trabalho objetivou avaliar as propriedades físicas, químicas, biológicas e mecânicas de próteses mamárias de silicone explantadas. Os parâmetros de avaliação basearam-se na norma NBR 14 760 – 2001. Foram analisadas nove amostras de próteses mamárias de silicone texturizadas, com diferentes tempos de uso e os ensaios foram realizados em triplicata. Os ensaios de caracterização utilizados foram Microscopia Óptica - MO, Espectroscopia na Região do Infravermelho com Transformada de Fourier (FTIR), Coesividade do Gel, Ensaio Mecânico (Resistência a Tração) e Citotoxicidade. No ensaio de MO verificou-se padrões diversos de texturizações para as próteses, mas não foram observadas alterações significativas que comprometesse a qualidade das próteses mamárias, bem como nos espectros de FTIR. Baseado nos resultado obtidos no ensaio de coesividade do gel pode-se afirmar que apenas a amostra C não se encontra em conformidade com a norma International Standard ISO 14607. Nos resultados do Ensaio Mecânico, as amostras A, B, F, G e H encontraram-se em não conformidade com a norma. Os testes de citotoxicidade mostraram que as próteses analisadas estão em conformidade com a norma. Desta forma conclui-se que as amostras A, B, C, F, G e H estão fora dos parâmetros exigidos pelas normas vigentes e que o tempo de uso destas pode ter influenciado nestes resultados, sugerindo-se a continuidade de estudos considerando essa variável. / Breast implants are characterized as medical devices that are used to increase the size of breasts or to reconstruct the breast after mastectomy or to correct a congenital anomaly. It is known that deviations in the production process of breast implants and the use of time can reduce the properties of the final product and favor risk of harm to health. Thus, this study aimed to evaluate the physical, chemical, biological and mechanical properties of silicone breast implants explanted. The evaluation criteria were based on NBR 14 760 - 2001 were analyzed nine samples of textured silicone breast implants with different operating times and the assays were performed in triplicate. Characterization tests used were Microscopy Optica - MO, Infrared Spectroscopy in the Region Fourier Transform (FTIR), cohesiveness gel, Mechanical Test (Tensile Strength) and cytotoxicity. In the MO of study there are several standards for texturing the prosthesis, but no significant changes were observed that could compromise the quality of breast implants, as well as in FTIR spectra. Based on the results obtained in the gel assay cohesiveness, it can be stated that only sample C is not in accordance with International Standard ISO 14607.Nos results of mechanical testing, samples A, B, F, G and H found in noncompliance with the standard. Cytotoxicity tests showed that the prostheses are analyzed in accordance with the standard. Thus it is concluded that the samples A, B, C, F, G and H are out of the parameters required by current standards and that the time of use these may have influenced these results, suggesting continuing studies considering this variable .
25

Avaliação da sensibilidade no trajeto do nervo intercostobraquial, em mulheres com linfadenectomia axilar, pós-cirurgia por câncer de mama / Evaluation of the sensibility in the region of the intercostobrachial nerve, in women with linfadenectomia axillary after surgery for breast cancerBreast Cancer. Innervation. Evaluation.

Marina Scarulis Mamede dos Santos 04 July 2008 (has links)
A cirurgia da remoção da mama, associada à linfadenectomia axilar, tem sido o tratamento tradicional do câncer de mama. Apesar dos seus benefícios, a cirurgia está associada a algumas seqüelas e complicações, entre elas, as alterações de sensibilidade no trajeto do nervo intercostobraquial. Objetivos: Analisar, através do estesiômetro de Semmes-Weinstein, as alterações de sensibilidade no trajeto do nervo intercostobraquial, em mulheres que realizaram linfadenectomia axilar, por câncer de mama; identificar os descritores de alteração de sensibilidade, segundo a percepção dessas mulheres; comparar a sensibilidade entre mulheres com e sem linfadenectomia axilar; comparar a percepção da sensibilidade de mulheres com linfadenectomia com a resposta obtida com a utilização do estesiômetro. Métodos: Foi aplicado o estesiômetro de Semmes-Weinstein para a avaliação da sensibilidade no trajeto do nervo intercostobraquial e um questionário com dados pessoais e sociodemográficos, acerca do tratamento e sobre a percepção da sensibilidade no membro superior. Participaram desse estudo, 94 mulheres, divididas em dois grupos: um grupo composto por 47 mulheres que realizaram linfadenectomia axilar por câncer de mama e um grupo composto por 47 mulheres não diagnosticadas por câncer de mama e sem qualquer tipo de cirurgia nas axilas. Em cada participante foi realizado o teste com o estesiômetro, por duas vezes consecutivas, e no grupo com cirurgia, também foi aplicado o questionário. Resultados: A prevalência de alteração de sensibilidade, avaliada por meio do estesiômetro de Semmes-Weinstein foi alta, mostrando que 85,1% das mulheres do grupo com linfadenectomia axilar tiveram respostas abaixo dos valores considerados de normalidade, baseado nas respostas do grupo sem linfadenectomia axilar. Foi confirmada a repetibilidade na aplicação do estesiômetro, no grupo com linfadenectomia, através do teste de Kappa (p = 0,8696). O sintoma mais relatado foi adormecimento (70,2%). Conclusões: Na população desse estudo, a queixa de alterações de sensibilidade teve alta prevalência e consideramos o estesiômetro um aparelho de fácil aplicação na prática clínica, baixo custo e confiável. Porém, enfatizamos a importância do treinamento do profissional que irá aplicá-lo e a padronização do teste, de acordo com as orientações do fabricante. / The surgery of the removal of the breast associated to the axillary lymph node dissection has been the traditional treatment for breast cancer. In spite of their benefits, the surgery is associated some sequels and complications, among them the sensibility alterations in the region of the intercostobrachial nerve. Objective: To analyze the sensibility alterations around intercostobrachial nerve in women who were operated by axillary lymph node dissection, for breast cancer through the Semmes- Weinstein monofilament testing; to identify the subject headings of sensibility alteration according to those women\'s perception; to compare the sensibility among women with and without axillary lymph node dissection; and to compare the perception of the women\'s sensibility with axillary lymph node dissection with the answer obtained by the Semmes-Weinstein monofilament testing. Methods: The Semmes-Weinstein monofilament testing was applied for the evaluation of the sensibility in the region of the intercostobrachial nerve and a questionnaire with personal data and sociologically demographic aspects, concerning the treatment and about the perception of the sensibility in the superior member. In that study, 94 women took part in, divided in two groups. A group composed by 47 women that were operated by axillary lymph node dissection for breast cancer and a group composed by 47 women no diagnosed by breast cancer and without any axillary surgery. In each participant the test was accomplished with the monofilament for twice consecutive and in the group with surgery the questionnaire was applied also. Results: The prevalence of sensibility alteration, appraised through the Semmes-Weinstein monofilament testing it was high, 85,1% of the group with axillary lymph node dissection had answers below the considered values of normality, based on the answers of the group without axillary surgery. The repeatability was confirmed in the application of the monofilament in the group with axillary lymph node dissection through the test of Kappa (p=0,8696). The symptom more told was numbness (70,2%). Conclusions: In the population of that study, the complaint of sensibility alterations had high prevalence and we considered the Semmes-Weinstein monofilament testing appliance of easy application in practice clinic, low cost and reliable. However we emphatize the importance of the professional\'s training that will apply it and the standardization of the test in agreement with the manufacturer\'s orientations.
26

Papel da nova citocina FAM3B/PANDER na progressão tumoral em câncer de mama. / Role of new cytokine FAM3B/PANDER in breast tumor progression.

Izabela Daniel Sardinha Caldeira 25 August 2016 (has links)
FAM3B/PANDER, é uma nova proteína tipo citocina pertencente a família FAM3. Foram reveladas algumas similaridades estruturais entre o FAM3B e outras citocinas associadas ao câncer, como IL-6 e FAM3C suportando a hipótese, de que FAM3B também poderia estar envolvido na progressão tumoral. Considerando que o FAM3B é expresso por tumores de mama, este trabalho dedicou-se a elucidar suas possíveis funções em tumores, a partir de um modelo de superexpressão na linhagem celular tumoral da mama, MDA-MB-231. Ensaios celulares e moleculares sugeriram que o FAM3B é capaz de conferir, proteção à morte celular e de aumentar taxa de migração nas células MDA-MB-231 via, principalmente, Bcl-2 e Bcl-xL. Em concordância, os resultados in vivo demonstraram aumento do volume e peso tumoral, com aumento da expressão de Bcl-2 nos tumores dos animais inoculados com as células MDA-MB-231-FAM3B. Estes resultados indicam que esta proteína, exerce funções nas etapas de invasão e metástase em tumores de mama, o que permite considerar o FAM3B, como um possível candidato a marcador tumoral. / FAM3B/PANDER is a new cytokine-like protein, member of the new FAM3 family. Recent data has been shown similarities between FAM3B/PANDER and others citokines involved in tumor progression, like IL-6 and FAM3C/ILEI, supporting the hypothesis that FAM3B is also involved in tumor progression. In Silico data revealed that FAM3B is expressed by breast tumors and using the overexpression of FAM3B in MDA-MB-231 tumor cell line, the aim was evaluated possible roles of FAM3B in breast tumor progression. The results revealed that FAM3B overexpression inhibits cell death and promotes cell migration in MDA-MB-231 cell line, through, at least in parts, Bcl-2 and Bcl-xL pathways. In agreement, in vivo results shown an increase in volume, weight tumors and increase expression of Bcl-2 in mice with cells overexpressing FAM3B.These results suggest important functions of this protein in cell invasiveness and migration, which allows us to consider, FAM3B as a possible future candidate as a molecular biomarker.
27

Estudo preliminar da farmacocinética da doxorrubicina e avaliação do ajuste de dose em mulheres com cancêr de mama / Preliminary investigation of the pharmacokinetics of doxorubicin and evaluation of dose adjustment in women with breast cancer

Barpe, Deise Raquel January 2009 (has links)
Objetivos: Simular um ajuste de dose em pacientes com sobrepeso e com obesidade que utilizam a doxorrubicina (DOX), que proporcione curvas de concentração plasmática e concentrações máximas (Cmáx) semelhantes às de pacientes com peso normal. Metodologia: Determinou-se as concentrações plasmáticas de DOX em pacientes com câncer de mama após a administração i.v. de 60 mg/m2, com ajuste de dose pelo BSA e com tempo de infusão de 40 minutos (0,66 h). As pacientes foram divididas em três grupos: a) pacientes com peso normal (IMC até 24,9) (n = 3); b) pacientes com sobrepeso (IMC 25,0 – 29,9) (n = 5); c) pacientes com obesidade (IMC acima 30,0) (n = 2). Os tempos de coleta utilizados foram: 0,66, 1,66, 8,66, e 24,66 h. Os perfis farmacocinéticos da DOX foram avaliados após quantificação da DOX através de metodologia por CLAE desenvolvida e validada. Resultados e Discussão: Os parâmetros farmacocinéticos ASC e Cmáx foram analisados por abordagem não-compartimental e compartimental. Em ambas as análises encontraram-se diferenças significativas (α = 0,05) entre os grupos com sobrepeso e com obesidade comparados com o grupo com peso normal para ASC e diferenças significativas entre o grupo com sobrepeso comparado ao grupo de pacientes com peso normal para o Cmáx. Após simulação de ajuste de dose pelo peso e pelo IMC, para as pacientes com sobrepeso e obesas, obtivemos novos valores de ASC e Cmáx. Houve diferenças significativas (α = 0,05) para o grupo de pacientes com sobrepeso comparado ao grupo com peso normal para a ASC e nenhuma diferença significativa entre os grupos estudados para Cmáx. Os percentuais de diferença da ASC e Cmáx do grupo das pacientes com sobrepeso e obesas comparados com o grupo de pacientes com peso normal foram diminuindo quando a dose era ajustada pelo peso e IMC. Conclusões: O ajuste de dose pelo índice BSA, comumente usado na prática clínica, não produz concentrações plasmáticas iguais em grupos de pacientes com peso normal e com sobrepeso, indicando que outros índices devem ser considerados, como peso e IMC. / Objectives: to simulate a dose adjustment in patients with overweight and obesity using doxorrubicin (DOX), providing plasma concentrations similar to those of patients with normal weight. Methodology: plasma concentrations of DOX were determined in patients with breast cancer after the iv. administration of 60 mg/m2 of DOX, adjusted by the BSA and with an infusion time of 40 minutes (0.66 h). The patients were divided into three groups: (a) patients with normal weight (BMI < 24.9) (n = 3); b) patients with overweight (BMI 25.0 – 29,9) (n = 5); c) patients obese (BMI > 30.0) (n = 2). Samples were collected at 0.66, 1.66, 8.66, and 24,66 h. DOX's pharmacokinetic profiles were evaluated after quantification of DOX using a new HPLC method developed and validated. Results and discussion: pharmacokinetic parameters (AUC and Cmax) were analyzed by non-compartmental and compartmental approaches. Significant differences (α = 0.05) between overweight and obese groups when compared with the normal weight group were found with respect to AUC and significant difference between the group with overweight compared to the patients with normal weight was found for Cmax. After simulating the dose adjustment by weight and by BMI for overweight and obese patients, new values for Cmax ASC were calculated. The new values obtained using both weight and BMI were closer to the normal group than those obtained with the BSA. The percentage of difference of ASC and Cmax of the overweight and obese group compared with the Group of patients with normal weight were lower when the dose was adjusted by weight and IMC. Conclusions: dose adjustment index BSA, commonly used in clinical practice, produced different plasma concentrations in groups of patients with normal weight, overweight, and obese, indicating that other indexes must be considered, such as weight and BMI.
28

Microcalcificações amorfas agrupadas na mamografia digital de campo total: correlação anatomopatológica / Grouped amorphous microcalcifications in full-field digital mamography: anatomopathologic correlation

Ferreira, Vera Christina Camargo de Siqueira 08 March 2012 (has links)
INTRODUÇÃO: O objetivo deste estudo é determinar a correlação anatomopatológica das calcificações amorfas agrupadas diagnosticadas na mamografia digital de campo total, ou seja, das calcificações suspeitas mais tênues, uma vez que houve aumento da caracterização de calcificações na mamografia digital. MÉTODOS: Estudo retrospectivo baseado nos laudos mamográficos classificados como categoria BI-RADS 4 no primeiro ano de introdução da técnica digital, com análise dos diagnósticos anatomopatológicos das microcalcificações amorfas agrupadas submetidas à biópsia de fragmento assistida à vácuo no serviço. Calculou-se: os achados anatomopatológicos que se associaram ao achado radiológico de microcalcificações amorfas agrupadas e o valor preditivo positivo destas calcificações biopsiadas. RESULTADOS: Dos 219 achados por microcalcificações amorfas agrupadas, 78 foram submetidos à biópsia de fragmento assistida à vácuo com seguimento conhecido ou cirurgia subsequente. O diagnóstico anatomopatológico correspondeu a oito (10%) casos malignos, 36 (46%) casos benignos, e 34 (44%) diagnósticos de lesões de risco, das quais oito (10%) do subgrupo cicatriz radiada/lesões papilíferas (sete cicatrizes radiadas e um papiloma) e 26 (33%) do subgrupo atipias/ neoplasias lobulares, correspondendo a 14 (18%) hiperplasias ductais atípicas, quatro (5%) neoplasias lobulares e oito (10%) lesões de células colunares com atipia (atipia epitelial plana). A ampliação cirúrgica foi recomendada para as lesões com potencial incerto de malignidade à biópsia e realizada em 65% do subgrupo atipias/neoplasias lobulares, com taxa de subestimação nula (0/18). O tempo médio de seguimento das pacientes com diagnóstico benigno ou de lesão de risco foi 22 meses. CONCLUSÕES: Um terço das microcalcificações amorfas agrupadas em mamografia digital de campo total corresponderam a lesões precursoras representadas pelas atipias (ductais e colunares) e neoplasias lobulares. Essas lesões se associaram às calcificações amorfas agrupadas numa proporção de cerca de 3:1 em relação às lesões malignas, cujo VPP 3 foi 10% / PURPOSE: To determine the anatomopathological correlation of grouped amorphous calcifications (the most tenuous of suspicious calcifications) disclosed on full-field digital mammography, given the enhanced characterization of calcifications provided by digital mammography. METHODS: A retrospective study of mammographic reports classified as BI-RADS® category 4 at a private diagnostic service specialized in breast imaging was carried out on exams performed during the first year of introducing the digital technique. The investigation entailed analysis of the anatomopathological diagnoses of BI-RADS® category 4 for grouped amorphous microcalcifications submitted to vacuum-assisted breast biopsy (VABB). Anatomopathological findings correlated to this radiological finding were determined and positive predictive value of these calcifications submitted to biopsy (PPV 3) was calculated. RESULTS: Of the 219 findings of grouped amorphous microcalcifications, 78 were submitted to VABB with known follow-up or subsequent surgery. The anatomopathological results included eight (10%) malignant cases, 36 (46%) benign cases and 34 (44%) diagnoses of high-risk lesions, eight of which belonged to the radial scar/papillary lesion subgroup (seven radial scars and one papilloma) and 26 (33% of all cases) to the atypia/lobular neoplasia subgroup, comprising 14 atypical ductal hyperplasias, four lobular neoplasias and eight flat epithelial atypia. Extended surgery was recommended for lesions with uncertain malignant potential at biopsy and performed in 65% of the atypia/lobular neoplasia subgroup, with an underestimation rate of zero (0/18). Mean follow-up time of patients diagnosed with benign or high-risk lesions was 22 months. CONCLUSIONS: One-third of grouped amorphous calcifications on full-field digital mammography corresponded to precursory lesions in the form of atypia (ductal and columnar) or lobular neoplasias. These lesions were associated to grouped amorphous calcifications at a ratio of 3:1 compared to malignant lesions,whose PPV 3 was 10%
29

Pesquisa de instabilidade gênica induzida por quimioterapia antineoplásica nas células mononucleares do sangue periférico de mulheres com câncer de mama / Systemic chemotherapy induces microsatellite instability in the peripheral blood mononuclear cells of breast cancer patients

Fonseca, Fernando Luiz Affonso 17 June 2005 (has links)
O tratamento sistêmico é extremamente importante na abordagem clínica do câncer de mama. O presente estudo teve a finalidade de avaliar se a quimioterapia sistêmica é capaz de produzir instabilidade genética representada por instabilidade de microssatélites (MSI) e perda de heterozigosidade (LOH) na fração mononuclear do sangue periférico de pacientes portadoras de câncer de mama. Foram estudadas 119 amostras de sangue, obtidas seqüencialmente antes, durante e após a quimioterapia. Das 30 pacientes avaliadas, 27 apresentaram MSI em pelo menos uma das amostras estudadas e 6 desenvolveram LOH. Uma importante correlação foi obtida entre o número de eventos de MSI por amostra e quimioterápicos com agentes alquilantes (p < 0,0001). Entretanto, quando as amostras foram de pacientes em radioterapia, observou-se um menor número de eventos de MSI por amostra (p=0,038). Concluímos que o tratamento sistêmico pode induzir MSI e LOH em células mononucleares do sangue periférico de pacientes em tratamento quimioterápico com agentes alquilantes / Systemic chemotherapy is an important part of treatment for breast cancer. We conduced the present study to evaluate whether systemic chemotherapy could produce microsatellite instability (MSI) in the peripheral blood mononuclear cell fraction of breast cancer patients. We studied 119 sequential blood samples from 30 previously untreated breast cancer patients before, during and after chemotherapy. In 27 out of 30 patients we observed MSI in at least one sample, and six patients had loss of heterozygosity (LOH). We found a significant correlation between the number of MSI events per sample and chemotherapy with alkylating agents (p < 0.0001). However, when the samples were obtained in patients with radiotherapy we observed low MSI events per samples (p = 0.038). We concluded that systemic chemotherapy may induce MSI and LOH in peripheral blood mononuclear cells from breast cancer patients receiving alkylating agents
30

Microcalcificações amorfas agrupadas na mamografia digital de campo total: correlação anatomopatológica / Grouped amorphous microcalcifications in full-field digital mamography: anatomopathologic correlation

Vera Christina Camargo de Siqueira Ferreira 08 March 2012 (has links)
INTRODUÇÃO: O objetivo deste estudo é determinar a correlação anatomopatológica das calcificações amorfas agrupadas diagnosticadas na mamografia digital de campo total, ou seja, das calcificações suspeitas mais tênues, uma vez que houve aumento da caracterização de calcificações na mamografia digital. MÉTODOS: Estudo retrospectivo baseado nos laudos mamográficos classificados como categoria BI-RADS 4 no primeiro ano de introdução da técnica digital, com análise dos diagnósticos anatomopatológicos das microcalcificações amorfas agrupadas submetidas à biópsia de fragmento assistida à vácuo no serviço. Calculou-se: os achados anatomopatológicos que se associaram ao achado radiológico de microcalcificações amorfas agrupadas e o valor preditivo positivo destas calcificações biopsiadas. RESULTADOS: Dos 219 achados por microcalcificações amorfas agrupadas, 78 foram submetidos à biópsia de fragmento assistida à vácuo com seguimento conhecido ou cirurgia subsequente. O diagnóstico anatomopatológico correspondeu a oito (10%) casos malignos, 36 (46%) casos benignos, e 34 (44%) diagnósticos de lesões de risco, das quais oito (10%) do subgrupo cicatriz radiada/lesões papilíferas (sete cicatrizes radiadas e um papiloma) e 26 (33%) do subgrupo atipias/ neoplasias lobulares, correspondendo a 14 (18%) hiperplasias ductais atípicas, quatro (5%) neoplasias lobulares e oito (10%) lesões de células colunares com atipia (atipia epitelial plana). A ampliação cirúrgica foi recomendada para as lesões com potencial incerto de malignidade à biópsia e realizada em 65% do subgrupo atipias/neoplasias lobulares, com taxa de subestimação nula (0/18). O tempo médio de seguimento das pacientes com diagnóstico benigno ou de lesão de risco foi 22 meses. CONCLUSÕES: Um terço das microcalcificações amorfas agrupadas em mamografia digital de campo total corresponderam a lesões precursoras representadas pelas atipias (ductais e colunares) e neoplasias lobulares. Essas lesões se associaram às calcificações amorfas agrupadas numa proporção de cerca de 3:1 em relação às lesões malignas, cujo VPP 3 foi 10% / PURPOSE: To determine the anatomopathological correlation of grouped amorphous calcifications (the most tenuous of suspicious calcifications) disclosed on full-field digital mammography, given the enhanced characterization of calcifications provided by digital mammography. METHODS: A retrospective study of mammographic reports classified as BI-RADS® category 4 at a private diagnostic service specialized in breast imaging was carried out on exams performed during the first year of introducing the digital technique. The investigation entailed analysis of the anatomopathological diagnoses of BI-RADS® category 4 for grouped amorphous microcalcifications submitted to vacuum-assisted breast biopsy (VABB). Anatomopathological findings correlated to this radiological finding were determined and positive predictive value of these calcifications submitted to biopsy (PPV 3) was calculated. RESULTS: Of the 219 findings of grouped amorphous microcalcifications, 78 were submitted to VABB with known follow-up or subsequent surgery. The anatomopathological results included eight (10%) malignant cases, 36 (46%) benign cases and 34 (44%) diagnoses of high-risk lesions, eight of which belonged to the radial scar/papillary lesion subgroup (seven radial scars and one papilloma) and 26 (33% of all cases) to the atypia/lobular neoplasia subgroup, comprising 14 atypical ductal hyperplasias, four lobular neoplasias and eight flat epithelial atypia. Extended surgery was recommended for lesions with uncertain malignant potential at biopsy and performed in 65% of the atypia/lobular neoplasia subgroup, with an underestimation rate of zero (0/18). Mean follow-up time of patients diagnosed with benign or high-risk lesions was 22 months. CONCLUSIONS: One-third of grouped amorphous calcifications on full-field digital mammography corresponded to precursory lesions in the form of atypia (ductal and columnar) or lobular neoplasias. These lesions were associated to grouped amorphous calcifications at a ratio of 3:1 compared to malignant lesions,whose PPV 3 was 10%

Page generated in 0.0313 seconds