• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 449
  • 10
  • 3
  • 1
  • 1
  • Tagged with
  • 464
  • 319
  • 247
  • 98
  • 75
  • 68
  • 67
  • 55
  • 55
  • 40
  • 37
  • 35
  • 31
  • 29
  • 27
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
331

[en] TECHNOLOGICAL INNOVATION: CONTRIBUTIONS OF METROLOGY AND USER-LED INNOVATION / [pt] INOVAÇÃO TECNOLÓGICA: CONTRIBUIÇÃO DA METROLOGIA E DO USUÁRIO GERADOR DE INOVAÇÃO

GLAUDSON MOSQUEIRA BASTOS 30 October 2018 (has links)
[pt] A dissertação de mestrado desenvolve-se em sintonia com as prioridades do Programa de Pós-Graduação em Metrologia para Qualidade e Inovação da PUC-Rio, inserindo-se na sua linha de pesquisa Negócios, Inovação e Metrologia. Dois são os objetivos do presente trabalho: (i) identificar os mecanismos de contribuição da metrologia ao processo de inovação e (ii) caracterizar o papel do usuário beneficiário da inovação nesse processo. A metodologia empregada compreende uma revisão da literatura especializada sobre os temas da pesquisa e o desenvolvimento de um estudo de caso na indústria metro-ferroviária brasileira. A amostra intencional é constituída por profissionais de PeD de algumas das principais concessionárias brasileiras de transporte ferroviário de cargas e de passageiros. O trabalho se desenvolve no contexto do papel crescente da inovação tecnológica como estratégia para competitividade empresarial e inserção externa das empresas brasileiras, um dos pilares da Política Industrial Tecnológica e de Comércio Exterior (PITCE) e de sua sucedânea Política de Desenvolvimento Produtivo (PDP) lançada em maio de 2008. Em seus resultados, o trabalho analisa, em um primeiro momento, (i) o tipo de inovação promovida na indústria metro-ferroviária e (ii) a conformidade dos projetos inovadores nesta indústria com as normas emanadas do Comitê Brasileiro de Normalização ABNT/CB-06 - Metroferroviário da Associação Brasileira de Normas Técnicas (ABNT), para então avaliar (iii) o papel da metrologia e dos usuários no processo da inovação tecnológica propriamente dita. As conclusões destacam que a indústria metro-ferroviária no Brasil adota um viés conservador na seleção de projetos de inovação e que a prática da inovação induzida por usuários ainda não se encontra plenamente difundida, em que pese o elevado nível de acesso dos usuários ás especificações de projeto e desenvolvimento de produto. Outrossim, o trabalho permitiu concluir que, no caso da indústria metro-ferroviária, as normas técnicas e regulamentos técnicos impulsionam e orientam o processo de inovação. / [en] The subject of the master s dissertation reflects the priorities of the Pontifical Catholic University of Rio de Janeiro s Graduate Program in Metrology for Quality and Innovation, particularly its research line Business, Innovation and Metrology. The research has two objectives: (i) to identify the mechanisms through which metrology contribute to innovation and (ii) to characterize the role of innovationbenefited users in the very innovation process. The methodology employed comprises a literature review of the topic and development of a case study in the Brazilian subway-railway transportation and equipment industry. An intentional sample was formed by R and D professionals of the major passenger and freight railway Brazilian concessionaire firms. The work is developed in the context of the growing role of innovation as a strategic component of business competitiveness and of innovation as one of the pillars of the country s Foreign Trade and Industrial and Technology Policy (PITCE), and its successor Productive Development Policy (PDP), launched in May 2008. The research project results analyze: (i) the type of innovation encouraged by the subway-railway industry and (ii) the conformity of innovative projects in the industry with norms issued by the National Standards Committee ABNT/CB-06 - Subway-railway of the Brazilian Technical Standards Association (ABNT), and then (iii) assesses the role of metrology and of innovation users in the very innovation process. The conclusions highlight that the subway-railway industry adopts a conservative approach in the selection of innovation projects and that the practice of user- induced innovation is not yet fully diffused, in spite of the high level of user access to project and product development specifications. Furthermore, the work allowed us to conclude that, in the case of the subway-railway industry, technical norms and regulations promote and orient the innovation process.
332

Confiabilidade Metrológica: o caso da análise de DQO em um laboratório acadêmico. / Metrological Reliability: the case of the analysis of COD in an academic laboratory.

Érica Andrade Carvalho Mendez 11 April 2013 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / Desde 2004, o CONAMA (Conselho Nacional de Meio Ambiente), através de sua Resolução n 344, vem exigindo que as análises físicas, químicas e biológicas em matrizes ambientais sejam realizadas em laboratórios ambientais que possuam sua competência técnica reconhecida formalmente através da acreditação concedida pelo Inmetro. Assim, algumas Unidades Federativas vem adotando o mesmo critério para cadastramento de laboratórios em seus bancos de dados. Com isso, houve um crescimento no número de acreditações: em 2002 haviam 12 laboratórios acreditados e em 2012 foram concedidas 198 acreditações a laboratórios ambientais. A adoção da ABNT NBR ISO/IEC 17025 como padrão de trabalho, além de atender as legislações vigentes, possui as seguintes vantagens: satisfação do cliente, credibilidade e melhoria contínua do laboratório, melhoria da capacitação profissional e a conquista de um mercado mais amplo. Buscando adequar-se a essa realidade, apesar de todas as dificuldades inerentes ao processo de implementação dos requisitos da ABNT NBR ISO/IEC 17025 em laboratórios universitários e de pesquisa, o Laboratório de Engenharia Sanitária (LES/DESMA) priorizou a adequação da determinação da demanda química de oxigênio (DQO) aos requisitos técnicos da ABNT NBR ISO/IEC 17025:2005, por ser um parâmetro indicador global de matéria orgânica em águas residuárias e superficiais e ser amplamente utilizado no monitoramento de estações de tratamento de efluentes líquidos e pelo fato deste poder ser determinado por duas técnicas analíticas distintas: espectrofotometria e colorimetria. Em razão deste cenário, o objetivo deste trabalho foi avaliar o desempenho dos métodos 5220 B e 5220 D descritos pelo Standard Methods, através dos parâmetros de validação de métodos analíticos. Ambos os métodos mostraram-se adequados ao uso a que se destinam e o limite de quantificação determinado apresentou-se compatível com o praticado com os laboratórios acreditados. As incertezas foram calculadas de forma a quantificar a qualidade do resultado. / Since 2004, CONAMA - National Council for the Environment - through its Resolution No. 344, has demanded that the physical, chemical and biological environmental matrices are performed in environmental laboratories that have formally acknowledged their technical competence through accreditation granted by Inmetro. Since then, some Federal Units has adopted the same criteria for laboratories registration in their databases. With that, there was an increase in the number of accreditations: in 2002 there were 12 accredited laboratories and in 2012 were granted accreditation to 198 environmental laboratories. The adoption of ABNT NBR ISO / IEC 17025 as the standard of work, in addition to attend the existing laws, has the following advantages: customer satisfaction, continuous improvement and credibility of the lab, professional skills improvement and the gain of a broader market. Seeking to adapt to this reality, despite of all the difficulties inherent in the process of implementing the requirements of ABNT NBR ISO / IEC 17025 in university and research laboratories, the Laboratory of Sanitary Engineering - LES / DESMA - prioritized to determine the suitability of Chemical Oxygen Demand - COD to the technical requirements of ABNT NRB ISO / IEC 17025:2005, as a global indicator parameter of organic matter in wastewater and surface and be widely used in monitoring liquid effluent treatment stations and because this it can be determined by two different analytical techniques: colorimetry and spectrophotometry. Given this scenario, the objective of this study was to evaluate the performance of the methods 5220 B and 5220 D described by Standard Methods, using validation parameters of analytical methods. Both methods proved to be suitable for the intended use and the limit of quantification determined appeared to be compatible with the practiced with accredited laboratories. The uncertainties were calculated to quantify the quality of the result.
333

[en] ENERGY PRICE SIMULATION IN BRAZIL THROUGH DEMAND SIDE BIDDING / [pt] SIMULAÇÃO DOS PREÇOS DE ENERGIA NO LEILÃO DE EFICIÊNCIA ENERGÉTICA NO BRASIL

JAVIER LINKOLK LOPEZ GONZALES 18 May 2016 (has links)
[pt] A Eficiência Energética (EE) pode ser considerada sinônimo de preservação ambiental, pois a energia economizada evita a construção de novas plantas de geração e de linhas de transmissão. O Leilão de Eficiência Energética (LEE) poderia representar uma alternativa muito interessante para a dinamização e promoção de práticas de EE no Brasil. Porém, é importante mencionar que isso pressupõe uma confiança na quantidade de energia reduzida, o que só pode se tornar realidade com a implantação e desenvolvimento de um sistema de Medição e Verificação (M&V) dos consumos de energia. Neste contexto, tem-se como objetivo principal simular os preços de energia do Leilão de Eficiência Energética no ambiente regulado para conhecer se a viabilidade no Brasil poderia se concretizar. A metodologia utilizada para realizar as simulações foi a de Monte Carlo, ademais, antes se utilizou o método do Kernel com a finalidade de conseguir ajustar os dados a uma curva através de polinômios. Uma vez conseguida a curva melhor ajustada se realizou a análise de cada cenário (nas diferentes rodadas) com cada amostra (500, 1000, 5000 e 10000) para encontrar a probabilidade dos preços ficarem entre o intervalo de 110 reais e 140 reais (preços ótimos propostos no LEE). Finalmente, os resultados apresentam que a probabilidade de o preço ficar no intervalo de 110 reais e 140 reais na amostra de 500 dados é de 28,20 por cento, na amostra de 1000 é de 33,00 por cento, na amostra de 5000 é de 29,96 por cento e de 10000 é de 32,36 por cento. / [en] The Energy Efficiency (EE) is considered a synonymous of environmental preservation, because the energy saved prevents the construction of new generating plants and transmission lines. The Demand-Side Bidding (DSB) could represent a very interesting alternative for the revitalization and promotion of EE practices in Brazil. However, it is important to note that this presupposes a confidence on the amount of reduced energy, which can only take reality with the implementation and development of a measurement system and verification (M&V) the energy consumption. In this context, the main objective is to simulate of the prices of the demand-side bidding in the regulated environment to meet the viability in Brazil that could become a reality. The methodology used to perform the simulations was the Monte Carlo addition, prior to the Kernel method was used in order to be able to adjust the data to a curve, using polynomials. Once achieved the best-fitted curve was carried out through an analysis of each scenario (in different rounds) with each sample (500, 1000, 5000 and 10000) to find the probability of the price falling between the 110 real range and 140 real (great prices proposed by the DSB). Finally, the results showed that the probability of staying in the price range from 110 real nd 140 real data 500 in the sample is 28.20 percent, the sample 1000 is 33.00 percent, the sample 5000 is 29.96 percent and 10000 is 32.36 percent.
334

[en] SYSTEMATICAL ANALYSIS OF THE DGD PREDICTION METHODOLOGY IN HIGH CAPACITY OPTICAL SYSTEMS / [pt] ANÁLISE SISTEMÁTICA DA METODOLOGIA DE PREVISÃO DO DGD EM SISTEMAS ÓPTICOS DE ALTA CAPACIDADE

AGNALDO CIESLAK 15 December 2003 (has links)
[pt] Um estudo sistemático da metodologia de determinação da probabilidade do DGD ultrapassar um determinado valor máximo foi apresentado. A metodologia foi discutida sob o ponto de vista teórico, obtendo-se o resultado a partir de uma base de dados recebidos de fabricantes de cabos de fibra óptica. Efetuou-se a comparação com os dados coletados destes mesmos cabos, porém já implantados em backbone. O resultado deste comparativo sistemático, foi apresentado sob a forma de estatística do valor de DGD ultrapassar o valor máximo estabelecido na norma ITU-T, para sistemas de 10 e 40Gbps. A partir dos resultados obtidos foi importante a identificação de erros que remontam a origem do processo de fabricação de cabos de fibras ópticas, a restrição na sensibilidade dos equipamentos de medição o que leva a uma superestimação da probabilidade do DGD ultrapassar um certo valor máximo e o próprio conceito do guia TIA/EIA TSB107, que define o método para a obtenção destes resultados. A criticidade destes resultados pode levar a um erro na escolha de um sistema óptico de transmissão podendo gerar prejuízos muito significativos, sejam financeiro ou temporal. Foram propostas três recomendações para direcionar a metodologia a uma previsão mais confiável dos resultados obtidos a partir do método 2 TIA/EIA TSB107, gerando mais conforto para o projeto de sistemas de alta capacidade. / [en] A systematic study of the methodology that determines the probability of the DGD overcomes a settled maximum value was presented. The methodology was discussed in a theoretical way; the values were based on a database received from optical fibers manufacturers/cablers. A comparison was conducted taking in consideration these same cables already installed in two backbones. The result of this systematic comparison was presented, as a statistic of the DGD value exceeds certain maximum value established by the standard ITU-T for systems from 10 to 40Gbps. Based on these results, the identification of mistakes that ascends the beginning of manufacture process of the optical fiber cables was important. The restriction of the sensibility of measurement devices leads to a overestimation of the probability of the DGD exceeds a given maximum value and the concept of the guideline TIA/EIA TSB107, that defines the methodology of acquisition of these results. These critical results could lead to a mistake choosing the optical system transmission and cause loss profit as well as time delay in a project. There were proposed three recommendations in order to guide the methodology for a trustful preview of the obtained results from TIA/EIA method 2, offering more comfort for optical high capacity system design.
335

[en] METROLOGY AND PSYCHOMETRY: EVALUATION OF HAMILTON AND BECK SCALES FOR DEPRESSION AND ANXIET / [pt] METROLOGIA E PSICOMETRIA: AVALIAÇÃO DAS ESCALAS DE HAMILTON E BECK PARA DEPRESSÃO E ANSIEDADE

FLAVIA DE ABREU AUGUSTO PAES 08 February 2018 (has links)
[pt] Os transtornos de ansiedade e humor são disfunções emocionais freqüentes que muito repercutem na qualidade de vida humana. Testes psicométricos quantificam esses transtornos e orientam condutas clínicas. A aplicação de ferramentas e conceitos da metrologia pode contribuir para a garantia de confiabilidade dos instrumentos de medição psicométricos. Os objetivos do trabalho são a elaboração de uma proposta de harmonização entre termos utilizados em psicometria e as definições universais para terminologia de medição segundo o Vocabulário Internacional de Termos Fundamentais e Gerais de Metrologia (VIM); e a avaliação da confiabilidade metrológica dos inventários de Beck e Hamilton para quantificação de ansiedade e transtorno de humor. Foram realizados: (i) estudos bibliográficos dos termos da metrologia e psicometria para elaboração da proposta de harmonização; (ii) aplicação dos inventários de Beck (BAI e BDI) e Hamilton (HAM-A e HAM-D) a 100 pacientes (iii) avaliação de validade, de convergência de quantificação de transtornos e cálculo da incerteza de medição entre inventários de Beck e Hamilton; (iv) desenvolvimento e implementação da Análise de Seleção de Parâmetros dos Itens (ASPI), abordagem elaborada para identificação da capacidade de cada item de um inventário, em discernir entre os diferentes níveis de acometimento do constructo. Todos os inventários quantificam de modo equivalente somente os pacientes graves. BAI e BDI apresentaram os maiores percentuais de itens capazes de discernimento entre níveis de acometimento. A boa correspondência obtida entre as abordagens ASPI quantitativa e ASPI qualitativa caracterizou a capacidade preditiva dos indicadores quantitativos propostos na identificação de desempenho de item. / [en] The anxiety disorders and humor are very frequent dysfunctions emotional impact on the quality of human life. Psicométricos quantify these tests and clinical disorders guide ducts. The application of tools and concepts of metrology can contribute to ensuring reliability of psicométricos measurement instruments. Job objectives are the development of a proposal for harmonization between terms used in psicometria and universal definitions for measuring terminology in accordance with the international vocabulary of basic and general terms in Metrology (VIM); and the assessment of the reliability of Beck inventories metrology and Hamilton to quantification of anxiety and mood disorder. Were made: (I) studies bibliographical terms of metrology and psicometria for the establishment of the proposed harmonization; (ii) implementation of inventories of Beck (BAI and BDI) and Hamilton (ham and HAM-d) 100 patients (iii) assessment of validity, quantification of convergence and disorders of the measurement uncertainty calculation between inventories of Beck and Hamilton; (iv) development and implementation of the analysis of selecting parameters of items (ASPI) approach to identification of the capacity of each item of an inventory to discern between different levels of acometimento of construction. All inventories quantify equivalent only serious patients. BAI and BDI submitted the largest percentage of items capable of discernment among acometimento levels. Good match obtained between the approaches quantitative and qualitative ASPI ASPI characterised the predictive capacity of quantitative indicators proposed in item performance identification.
336

[en] METROLOGICAL EVALUATION OF THE V-CONE TYPE METER PERFORMANCE FOR WET GAS FLOW RATE MEASUREMENT / [pt] AVALIAÇÃO METROLÓGICA DO DESEMPENHO DO MEDIDOR TIPO V-CONE PARA MEDIÇÃO DE VAZÃO DE GÁS ÚMIDO

THIAGO BARRA VIDAL DE OLIVEIRA 15 February 2018 (has links)
[pt] O objetivo deste trabalho é avaliar o desempenho metrológico e o potencial de aplicação do medidor tipo v-cone para medição de vazão de gás natural em condições de gás úmido. Observa-se que os medidores do tipo placa de orifício, geralmente utilizados na medição de vazão de gás no segmento de Exploração e Produção (E e P), podem não representar a tecnologia mais adequada. O medidor v-cone representa uma tecnologia relativamente recente, que vem demonstrando bom desempenho para a medição de vazão e vem ganhando aceitação de órgãos reguladores. O interesse e a motivação do pesquisador residem na busca de maior exatidão na medição de vazão em condições operacionais adversas (gás úmido não especificado), sem impacto significativo sobre o custo do sistema. O presente trabalho, por meio de uma pesquisa bibliográfica e documental, apresenta o estágio atual de desenvolvimento da tecnologia de medição por v-cone e detalha as características dos sistemas de medição de vazão de gás natural, além de abordar as normas e regulamentos relacionados ao tema em questão. A fase experimental busca avaliar o desempenho do medidor por meio de uma investigação empírica realizada em laboratório, simulando condições de gás úmido encontradas em campo. Essa análise envolve também a determinação de erros e incertezas de medição. A pesquisa realizada, em conjunto com a avaliação dos resultados dos testes e das correlações utilizadas, demonstra que o medidor v-cone apresenta boa confiabilidade na medição de vazão de gás natural em escoamento de gás úmido, podendo ser utilizado em aplicações encontradas no segmento de E e P. / [en] The aim of this study is to evaluate the metrological performance and potential of use of the v-cone type meter for measuring the natural gas flow rate under wet gas conditions. The orifice plate type meters, that are usually used to measure the gas flow rate in the Exploration and Production segment (E and P), may not represent the most appropriate technology. The v-cone meter represents a relatively recent technology, which has shown good performance for the flow rate measurement and is gaining acceptance from the regulators. The interest and motivation of the researcher are related to the quest for greater flow rate measurement accuracy in adverse operating conditions (unspecified wet gas), with no significant impact on the cost of the system. This work, through a literature and documentary search, presents the current stage of development of the v-cone flow rate measurement technology and details the characteristics of natural gas flow rate measurement systems, in addition to addressing the standards and regulations relating to the subject. The experimental phase aims to evaluate the meter performance through an empirical research conducted in laboratory, by simulating wet gas conditions found in the field. This analysis also involves the determination of measurement errors and uncertainties. The research and the evaluation of test results and correlations show that the v-cone meter has good reliability in natural gas flow rate measurement under wet gas conditions, allowing it to be used in applications found in E and P.
337

Estudo e aplicação de medição com câmera de vídeo em máquinas de medição por coordenadas

Silva, Marlio Antonio da 26 January 2017 (has links)
Submitted by Maike Costa (maiksebas@gmail.com) on 2017-06-06T11:51:16Z No. of bitstreams: 1 arquivototal.pdf: 3218304 bytes, checksum: ceed68b62fab16215d2955936b2afcf1 (MD5) / Made available in DSpace on 2017-06-06T11:51:16Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 3218304 bytes, checksum: ceed68b62fab16215d2955936b2afcf1 (MD5) Previous issue date: 2017-01-26 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / It is evident that with the increasing advance of the manufacturing industry there is a need for an efficient quality control that meets this demand produced within an increasingly shorter period of time. As a result of this, Coordinate Measuring Machines (CMMs) are widely used for inspection of various components in the current industry, in addition to having the Computer Numeric Control (CNC) - which makes the measurement process much faster than conventional methods - can still measure numerous geometries, since they have several sensors that are suitable for various situations, therefore, there is hardly a configuration that the CMM can’t measure. Measurements made by a CMM can be divided into two groups: contact measurements and non-contact measurements. Contact measurements use the touch sensor, known as a probe, which collects coordinate points on the measured piece with the sensor deflection when touching. Non-contact measurements can be performed with the laser sensor or a digital camera. The present work of master dissertation aims to present some applications of non-contact measurements with the use of a CMM, which incorporates a Charge-Coupled Device (CCD) camera, in components such as fuel injectors nozzles, printed circuit boards and sphere of high accuracy, since these elements have geometries with dimensions less than 4 mm, making it impossible to measure with the use of the conventional contact measurement system. / É evidente que com o crescente avanço da indústria manufatureira exista a necessidade de um controle de qualidade eficiente, que atenda essa demanda produzida dentro de um espaço de tempo cada vez mais curto. Em função disto, as Máquinas de Medição por Coordenadas (MMC) são amplamente empregadas para inspeção de diversos componentes na indústria atual, pois além de contarem com o Comando Numérico Computacional (CNC) – o que torna o processo de medição muito mais rápido do que os métodos convencionais - podem ainda medir inúmeras geometrias, uma vez que dispõem de diversos sensores que são adequados para várias situações, por conseguinte, dificilmente haverá uma configuração que a MMC não possa medir. As medições efetuadas por uma MMC podem ser dividas em dois grandes grupos: as medições por contato e as medições sem contato. As medições por contato utilizam o sensor de toque, conhecido como apalpador, que coleta pontos coordenados na peça medida com a deflexão do sensor quando houver o toque. As medições sem contato podem ser realizadas com o sensor laser ou uma câmera digital. O presente trabalho de dissertação de mestrado tem como finalidade apresentar algumas aplicações de medições sem contato com a utilização de uma MMC, que incorpora uma câmera CCD (Charge-Coupled Device), em componentes como bicos injetores de combustível, placas de circuito impresso e esferas de alta exatidão, visto que esses elementos apresentam geometrias com dimensões inferiores a 4 mm, impossibilitando medições com o uso do sistema de medição por contato convencional.
338

[en] INFRARED OPTO-ELECTRONIC DEVICE FOR DETECTION AND MEASURING VELOCITY OF BALLS USED AS CLEANING ARTIFACTS OF HEAT EXCHANGERS / [pt] DISPOSITIVO OPTO-ELETRÔNICO NA FAIXA DO INFRAVERMELHO PARA DETECÇÃO E MEDIÇÃO DE VELOCIDADE DE ESFERAS UTILIZADAS COMO ARTEFATOS DE LIMPEZA DE TROCADORES DE CALOR

JOAO RICARDO CORTES NUNES 02 October 2018 (has links)
[pt] Esta dissertação de Mestrado teve por objetivo a concepção, desenvolvimento e validação de um dispositivo opto-eletrônico, que opera na faixa do infravermelho, para detecção e medição da velocidade de esferas em meios turvos. A motivação para desenvolvimento deste tema resultou da necessidade de controlar a circulação de esferas para instrumentar um sistema alternativo de limpeza de trocadores de calor de hidrogeradores, que faz uso de artefatos abrasivos de geometria esférica. O método utilizado fundamenta-se no processamento do sinal eletrônico gerado por um circuito que produz pulsos proporcionais ao tempo de passagem da esfera no interior do contador, a cada interrupção do feixe luminoso. O tratamento do sinal, gerado por pares de sensores opto-eletrônicos perpendiculares entre si e montados transversalmente ao fluxo de água de resfriamento que transporta as esferas, é realizado por um controlador lógico programável, que atribui inteligência ao sistema. Dentre os resultados obtidos, constatou-se que o dispositivo consegue detectar esferas circulantes quando transportadas por fluxos de água com diferentes graus de turbidez (ensaios em laboratório) ou quando em operação no ambiente da usina hidrelétrica, cuja opacidade da água de resfriamento é dada pela incrustação removida durante o processo de limpeza. Como conclusão, pode-se afirmar que o dispositivo opto-eletrônico proposto atende às necessidades do projeto de construção de um sistema alternativo de limpeza por esferas abrasivas, conseguindo descartar falsos positivos na contagem das esferas, a exemplo de bolhas de ar ou partículas de incrustação cujas dimensões críticas diferem daquelas das esferas abrasivas. / [en] This dissertation aimed at the design, development and validation of an optoelectronic device, operating in the infrared range, for counting and measuring the velocity of spheres in turbid media. The motivation to develop this theme resulted from the need to control the spheres circulation to implement an alternative system for cleaning heat exchangers used to cool hydrogenerators, which make use of spherical abrasive artefacts. The methodology used is based on the processing of the electronic signal generated by a circuit that produces pulses proportional to the time of passage of the sphere inside the meter, at each interruption of the light beam. The processing of the signal, which is generated by pairs of mutually perpendicular optoelectronic sensors and mounted transversely to the flow of cooling water carrying the spheres, is performed by a programmable logic controller, which provides intelligence to the system. Among the obtained results, it was verified that the device can detect circulating spheres both when transported by water flows with different degrees of turbidity (laboratory tests) and when in operation in the environment of the hydroelectric plant, whose opacity of the cooling water is given by the fouling removed during the cleaning process. As a conclusion, it can be stated that the proposed optoelectronic device meets the needs of the construction of the alternative system of cleaning by abrasive spheres and can eliminate false positives in the counting of the spheres, such as air bubbles or incrustation particles whose critical dimensions differ from those of the abrasive spheres.
339

Síntese de micro-ondas para padrões atômicos de frequência de césio¹³³ / Microwave Synthesizer for Cesium¹³³ Atomic Frequencies Standards

Felipe Arduini Otoboni 10 April 2013 (has links)
Esta dissertação propõe o projeto e a implementação de um sintetizador de sinal pertencente à banda X, com frequência de 9.192 GHz, para promover a transição atômica do átomo de césio durante o ciclo de operação do padrão atômico de frequência do CePOF/IFSC. Diferente do sintetizador em uso, este provê duas fontes de sinais, a fim de realizar a alimentação simétrica da cavidade de micro-ondas. A alimentação simétrica apresenta uma melhoria em relação à montagem experimental atual e visa atenuar os efeitos de gradiente de potência ao quais os átomos estão expostos enquanto cruzam a cavidade de interrogação. O sintetizador também apresenta um controle de fase em um dos sinais, para que seja possível um ajuste de fase entre eles, permitindo que ambos cheguem à cavidade de interrogação em fase. O método utilizado para a síntese dos sinais é o indireto, onde o sinal de interesse é obtido por meio de osciladores e componentes que possibilitam a manipulação algébrica das frequências, aliados aos circuitos de travamento para controle dos osciladores / This text considers the design and implementation of an X-band signal synthesizer, with a 9.192 GHz frequency, to promote the atomic transition of cesium during the operation process of the CePOF/IFSCs atomic frequency standard. Unlike the current synthesizer, the present one provides two sources of signal, in order to perform the symmetrical feed of the microwave cavity. The symmetrical feed is an improvement compared to the current experimental set up and aims at reducing the power gradient effects to which the atoms are exposed when travelling throughout the interrogation cavity. The synthesizer also has a phase control in one of the signals, in order to ensure that both signals will get into the interrogation cavity in phase. The synthesis method used is the indirect one; the desired signal is formed by means of oscillators and devices that allow the algebraic manipulation of frequencies, combined with lock circuits to control the oscillators
340

Determinação da constante de solubilidade do azoteto de prata / Determination of the solubility constant of the silver azide

Fernanda Tomé Braz 26 July 2002 (has links)
A constante de solubilidade do azoteto de prata, AgN3, foi avaliada por meio da sua solubilidade em água. A concentração de prata foi determinada em solução saturada de azoteto de prata a 25ºC utilizando a técnica de Espectrometria de Absorção Atômica com Chama obtevendo-se um valor de (2,7 ± 0,2) x10-5 mol L-1 com 95% de confiança. A concentração de prata foi também determinada pela técnica Potenciométrica utilizando eletrodo de prata metálica tratado previamente com solução saturada diluída de AgN3 e a solubilidade obtida foi de (2,43 ± 0,09) x10-5 mol L-1 com 95% de confiança. As constantes de solubilidade calculadas pela equação Ks = (solubilidade )2 foram (7,3 ± 0,1) x 10-10 mol2 L-2 por Espectrometria de Absorção Atômica com Chama e (5,9 ± 0,1) x10-10 mol2 L-2 por Potenciometria. Esses valores de constante de solubilidade estão vinculados ao tamanho da partícula do precipitado de (27 ± 2) &#181;m. O grau de hidrólise do ânion azoteto foi avaliado medindo-se a variação de pH da água antes e após a saturação com o precipitado de azoteto de prata. A variação foi avaliada em (1,2 ± 0,6) x10-7 mol L-1 em relação à concentração de hidroxila liberada pela protonação do azoteto, valor este que se situou abaixo da variação da incerteza avaliada na solubilidade, razão pela qual não teve influência significativa (<0,5%). / The solubility constant of the silver azide, AgN3, was determined through its solubility in water. The concentration of silver was determined by a saturated solution of silver azide at 25 ºC with the Flame Atomic Absorption Spectrometer having a value of (2,7 ± 0,2) x 10-5mol L-1 with 95% of confidence. The concentration of silver was determined also by Potenciometric technical with an electrode of metallic silver previously treated with a saturated solution diluted of silver azide and the solubility obtained was (2,43 ± 0,09) x 10-5mol L-1 with 95% of confidence. The solubility constant calculated by the equation Ks = (solubility)2 were (7,3±0,1)x10-10 mol2 L-2 by FAAS and (5,9±0,1)x10-10 mol2L-2 by Potenciometry. These values of solubility constants are connected with the size of the precipitate of the (27 ± 2) &#181;m. The hidrolisys degree of the anion azide was determined trough the measuring of pH of pure water and pH after the saturation of water with the precipitate of silver azide. The variation was determined was (1,2 ± 0,6) x 10-7mol L-1 in terms of the concentration of hydroxyl liberated trough the protonation of azide. This value was lower than the uncertainty associated with the solubility of AgN3. In this way it was not taken in account (<0,5%).

Page generated in 0.0433 seconds