• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 453
  • 4
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 465
  • 465
  • 372
  • 367
  • 156
  • 87
  • 86
  • 80
  • 79
  • 76
  • 71
  • 69
  • 68
  • 65
  • 62
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
451

Impacto do ruído ocupacional na audição e qualidade de vida de trabalhadores inseridos em um programa de conservação auditiva / IMPACT OF OCCUPATIONAL NOISE ON HEARING AND QUALITY OF LIFE OF WORKERS POSTED IN A HEARING CONSERVATION PROGRAM.

Sampaio, Thadeu Acciari 28 April 2010 (has links)
Noise is the most common harmful physical agent found in the workplace. This hazardous agent gains more importance when it is proved that the hearing damage caused by it is irreversible, and that the continuous exposure produces other organic, physiological and psycho-emotional disturbances that result in lower life quality and health of workers. This work evaluated the degree of hearing loss and life quality related to the workers health exposed to occupational noise. A total of 110 male workers between 22 and 58 years old were evaluated, with time exposure to occupational noise varying between 3 and 28 years. The workers were submitted to an audiometric evaluation, answered a semi-structured survey and filled in a life quality quiz SF-36. Noise-Induced Hearing Loss (NIHL) was classified according to the diagnostic criteria proposed by Fiorini (1994). Out of the total, 87 (79.1%) presented hearing conditions within normal standards (Group 1) and 23 (20.9%) were classified as suggestive to NIHL (Group 2). Among the 87 audiograms from Group 1, 47 (54%) were within normal standards without loss, and 29 (33%) with unilateral loss. Out of the 23 audiograms from Group 2, 19 (82.6%) were suggestive of bilateral HLIN. In the semi-structured survey, the main complaints from Groups 1 and 2, respectively, were: (95.4%) and (95.7%), considered the workplace to be noisy and had difficulties hearing/understanding others (85%) and (82.6%). Every worker stated that they use safety equipment for the ears. There has not been found a connection between the exposure to noise at the workplace and bad life quality independently of the presence of hearing loss, comparing the dominants as well as the mental and physical components. There has been a relatively high rate of hearing loss, however, the presence of it associated or not to a noisy workplace did not determine a bad global life quality. / O ruído é o agente físico nocivo mais comum encontrado no ambiente de trabalho. Este agente pernicioso ganha maior importância quando se constata que o dano auditivo por ele ocasionado é irreversível, e que a exposição continuada produz outros distúrbios orgânicos, fisiológicos e psicoemocionais que resultam em diminuição da qualidade de vida e de saúde dos trabalhadores. Este estudo avaliou o impacto do ruído ocupacional na audição e qualidade de vida de trabalhadores inseridos em um programa de conservação auditiva. Foram avaliados 110 trabalhadores, do sexo masculino, com idades entre 22 a 58 anos, com tempo de exposição ao ruído ocupacional variando entre três e 28 anos. Os sujeitos realizaram avaliação audiométrica, responderam a um questionário semi-estruturado e preencheram o questionário de qualidade de vida SF-36. A Perda Auditiva Induzida por Ruído (PAIR) foi classificada segundo o critério diagnóstico proposto por Fiorini (1994). Do total, 87 (79,1%) apresentaram audição dentro dos padrões de normalidade (Grupo 1) e 23 (20,9%) foram classificados como sugestivos de PAIR (Grupo 2). Dentre os 87 audiogramas do Grupo 1, 47 (54%) foram dentro da normalidade sem entalhe, e 29 (33%) com entalhe unilateral. Dos 23 audiogramas do Grupo 2, 19 (82,6%) foram sugestivos de PAIR bilateral. No questionário semiestruturado, as principais queixas dos Grupos 1 e 2, respectivamente, foram: (95,4%) e (95,7%) consideram o ambiente de trabalho ruidoso e dificuldade de ouvir/entender as outras pessoas (85%) e (82,6%). Todos os trabalhadores relataram utilizar protetor auditivo. Não foi observada relação entre a exposição ocupacional ao ruído e má qualidade de vida independente da presença de perda auditiva, comparando tanto os domínios, quanto os componentes físico e mental. Houve uma taxa relativamente alta de perda auditiva, no entanto a presença da mesma associada ou não ao ruído ocupacional não determinou uma má qualidade de vida global.
452

Avaliação do genótipo de pacientes com Síndrome de Usher do Centro de Referência em Oftalmologia da Universidade Federal de Goiás / Evaluation of patients with genotype Reference Center Ophthalmology, Federal University of Goiás Usher Syndrome

Cruvinel Filho, Ricardo Campos 16 December 2014 (has links)
Submitted by Luciana Ferreira (lucgeral@gmail.com) on 2016-08-02T13:12:16Z No. of bitstreams: 2 Dissertação - Ricardo Campos Cruvinel Filho - 2014.pdf: 8513057 bytes, checksum: e42a2106d7e7abda6b1ee9d65068229d (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2016-08-02T13:28:23Z (GMT) No. of bitstreams: 2 Dissertação - Ricardo Campos Cruvinel Filho - 2014.pdf: 8513057 bytes, checksum: e42a2106d7e7abda6b1ee9d65068229d (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2016-08-02T13:28:23Z (GMT). No. of bitstreams: 2 Dissertação - Ricardo Campos Cruvinel Filho - 2014.pdf: 8513057 bytes, checksum: e42a2106d7e7abda6b1ee9d65068229d (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2014-12-16 / Cross-sectional study conducted at the Center of Reference in Ophthalmology UFG in conjunction with Oregon Health and Science University and the Brazilian Center for Eye Surgery (CBCO). To evaluate the genotype of patients with Usher syndrome of Reference Center for Ophthalmology, Federal University of Goias (UFG-CEROF). Patients clinically diagnosed with SU underwent complete ophthalmic examination, Goldmann manual kinetic perimetry, audiometry and subsequent collection of peripheral blood chromosomal microarray for sequencing. We examined 19 patients with clinical suspicion of SU with a mean age at first visit was 42.5 years (± 12.2) and a slight predominance of males (52.63%). The most prevalent subtype in clinical diagnosis of type I disease (68.4%). The visual acuity measured on the day of the exam for eye examination was 20/92 on the Snellen chart. Examinations audiometry showed hearing loss in all patients ranging from moderate in 12.5% of patients, deep (56.25%) and severe (31.25%). In 36.8% of patients analyzed, we found at least two mutations in the same gene, and of these, 21% were heterozygous mutations, and 15.8% homozygous. The homozygous mutations, which were of the type no sense, occurred in the gene CLRN1 whose patients had a previous diagnosis of USH 2. Met 26.31% of the sample analyzed in heterozygous. Of these, two patients showed mutations in the MYO7A gene (40%), both with clinical suspicion of USH 1. For the proposed methodology, we found no disease-causing mutations in 79% of the sample analyzed. Following the proposed methodology, the authors were able to determine the mutation in seven patients of nineteen patients inclued in this study. Of these, three patients were diagnosed with homozygous mutations in gene CLRN1, and had previous clinical diagnosis of type 2. Two patients had heterozygous mutations in gene MYO7A, both with previous clinical diagnosis of type 1. / Estudo transversal, desenvolvido no Centro de Referência em Oftalmologia da UFG em conjunto com a Oregon Health and Science University e Centro Brasileiro de Cirurgia de Olhos (CBCO), que teve como objetivo avaliar o genótipo de pacientes com síndrome de Usher do Centro de Referência em Oftalmologia da Universidade Federal de Goias (CEROF-UFG). Pacientes clinicamente diagnosticados com SU foram submetidos a exame oftalmológico completo, perimetria cinética manual de Goldmann, audiometria e posterior coleta de sangue periférico para sequenciamento cromossômico por microarray. Foram examinados 19 pacientes com diagnostico clínico de SU com média de idade na primeira consulta de 42,5 anos (± 12,2) e pequena predominância do sexo masculino (52,63%). O subtipo mais prevalente no diagnóstico clínico foi do tipo I da doença (68,4%). A acuidade visual média medida no dia do exame por olho examinado foi de 20/92 na escala de Snellen. Os exames audiométricos mostraram perda de audição em todos pacientes variando de moderada em 12,5% dos pacientes, profunda (56,25%) e severa (31,25%). Em 36,8% dos pacientes analisados, encontraram-se ao menos duas mutações em um mesmo gene, sendo que destes, 21% eram mutações heterozigotas e, 15,8% homozigotas. As mutações homozigotas, as quais eram do tipo sem senso, ocorreram no gene CLRN1, cujos pacientes tinham o diagnóstico clínico prévio de USH 2. Encontrou-se 26,31% da amostra analisada em heterozigose. Desses, dois pacientes mostraram mutações para o gene MYO7A (40%), ambos com suspeita clínica de USH 1. Pela metodologia proposta, não foram encontradas mutações causadoras de doença em 79% da amostra analisada. Dos 19 pacientes incluídos no presente estudo os autores conseguiram determinar a mutação de sete deles segundo a metodologia proposta. Desses, três pacientes foram diagnosticados com mutações homozigoticas todas no gene CLRN1 e possuíam diagnostico clinico prévio de SU tipo 2. Dois pacientes apresentaram mutações heterozigóticas para o gene MYO7A, ambos com diagnostico clinico prévio de SU tipo 1 e um paciente apresentou mutação heterozigótica para o gene ALMS1 que apresentava diagnostico clinico de SU tipo 1.
453

Prevalência de perda auditiva em recém-nascidos de muito baixo peso / Prevalence of very low birth weight neonates’ hearing loss

Uchôa, Natacha Toniazzi January 2003 (has links)
Objetivos: avaliar a prevalência de alterações auditivas em recém-nascidos de muito baixo peso na Unidade de Tratamento Intensivo Neonatal do Hospital de Clínicas de Porto Alegre e estudar as variáveis que possam estar relacionadas com as alterações da acui-dade auditiva. Métodos: foi realizado um estudo transversal que incluiu todos os recém-nascidos de muito baixo peso admitidos na Unidade de Tratamento Intensivo Neonatal do Hospital de Clínicas de Porto Alegre no período de 1o de setembro de 2001 a 31 de janeiro de 2002. To-dos os pacientes foram submetidos ao exame de otoemissão acústica evocada por produto de distorção no momento da alta hospitalar. O exame foi repetido em 30 dias quando havia alte-ração no primeiro exame. Quando o paciente apresentava o exame de otoemissão acústica al-terada em duas ocasiões, era realizado o potencial auditivo evocado cerebral, considerado al-terado a partir de 35 dB NA. Resultados: foram estudados 96 recém-nascidos. Seis tiveram tanto o exame de otoemissão acústica quanto o potencial auditivo evocado cerebral alterados. A média da idade gestacional foi de 31,5 ± 2,6 semanas, o peso de nascimento variou de 640 a 1.500 g e 57,3% dos pacientes eram do sexo feminino. A idade gestacional e o índice de Apgar no 5o minuto foram inferiores no grupo otoemissão acústica e potencial auditivo evocado cerebral alterados em relação aos demais grupos, atingindo significância limítrofe. Conclusões: a prevalência de perda auditiva nos recém-nascidos de muito baixo peso da Unidade de Tratamento Intensivo Neonatal do Hospital de Clínicas de Porto Alegre foi de 6,3%, tendo sido observadas associações de significância limítrofe com idade gestacional e índice de Apgar no 5o minuto. / Objectives: to evaluate the prevalence of hearing loss in very low birth weight patients in the Neonatal Intensive Care Unit of the Hospital de Clínicas de Porto Alegre and to study the variables that can be related to hearing loss. Methods: a transversal study was carried through including all very low birth weight neonates admitted in the Neonatal Intensive Care Unit of the Hospital de Clínicas de Porto Alegre during September 1, 2000 to January 31, 2002. All patients were undergone to the distortion evoked otoacoustic emission test in the hospital discharge. When the patient presented alteration in this test, it was repeated in 30 days. However, when the patient who presented pathologic otoacoustic emission on two ocasions was undergone to the auditory evoked brain response. This test was considered abnormal from 35 dB NA. Results: we studied 96 neonates. Six children presented alteration in the distortion evoked otoacoustic emission test as well in the auditory evoked brain response. The children age average was 31.5 ± 2.6 weeks, their birth weight was between 640 g and 1,500 g, and 57.3% of the patients were female. The gestational age and the Apgar score at 5 minutes were inferior in the otoacoustic emission and auditory evoked brain response abnormal group related to the other groups, reaching bordering significance. Conclusions: the hearing loss prevalence of the very low birth weight neonates from the Neonatal Intensive Care Unit of the HCPA was 6.3%, and it was observed bordering significance associations related to gestational age and 5 minutes Apgar score.
454

Referências anatômicas ao giro basal da cóclea no assoalho da fossa craniana média para o implante coclear / Anatomical references to the cochlear basal turn on the floor of the middle cranial fossa for cochlear implantation

Aline Gomes Bittencourt 29 May 2014 (has links)
Introdução: A técnica clássica para o implante coclear é realizada por meio de mastoidectomia seguida de timpanotomia posterior. O acesso pela fossa craniana média provou ser uma alternativa valiosa, embora seja usada para o implante coclear, ainda sem normatização. Objetivo: Descrever um novo acesso pela fossa craniana média que expõe o giro basal da cóclea para o implante coclear. Métodos: Estudo anatômico de ossos temporais. Foram dissecados 50 ossos temporais. A cocleostomia foi realizada mediante um acesso via fossa craniana média, na porção mais superficial do giro basal da cóclea, usando o plano meatal e seio petroso superior como as principais referências anatômicas. Foi determinada a distância entre os pontos de referência, o ângulo entre o plano meatal e a cocleostomia, e a distância entre esta estrutura e a janela redonda. Foi realizada tomografia computadorizada em 5 dos ossos temporais utilizados neste estudo. Resultados: Em todos os 50 ossos temporais, apenas a porção mais superficial do giro basal da cóclea foi aberta e tanto as escalas timpânica como a vestibular foram visualizadas. As distâncias médias ± DP, menores e maiores, entre a cocleostomia e o plano meatal foram estimadas em 2,48±0,88mm e 3,11±0,86mm, respectivamente. A distância média da cocleostomia até a janela redonda foi de 8,38±1,96mm, e daquela até o seio petroso superior 9,19±1,59mm. As distâncias médias, menores e maiores, entre a cocleostomia e o eixo longo do plano meatal a partir da sua porção mais proximal foram estimadas em 6,63±1,38mm e 8,2±1,43mm, respectivamente. O valor médio do ângulo entre a cocleostomia e o plano meatal foi igual a 22,54±7,400. As tomografias computadorizadas demonstraram a inserção do feixe de eletrodos por meio do giro basal da cóclea até o seu ápice em todas as peças submetidas a este exame. Conclusão: A técnica proposta para identificar o giro basal da cóclea é simples e confiável. Igualmente, permite a visualização da escala timpânica e a inserção do feixe de eletrodos do implante coclear através desta câmara / Introduction: The classic technique for cochlear implantation uses mastoidectomy followed by posterior tympanotomy. The middle cranial fossa approach has proved to be a valuable alternative for cochlear implantation, although the standardization of this technique is still needed. Objectives: To describe a novel approach through the middle cranial fossa for exposing the cochlear basal turn for cochlear implantation. Materials And Methods: Anatomical temporal bone study. Fifty temporal bones were dissected. A cochleostomy was performed via a middle fossa approach on the most superficial part of the cochlear basal turn, using the meatal plane and superior petrous sinus as the main landmarks. The distance between the landmarks, the angle between the cochleostomy and the meatal plane, and the distance between this structure and the round window were measured. A computed tomography was performed on 5 of the studied temporal bones. Results: In all 50 temporal bones, only the superficial portion of the cochlear basal turn was uncovered. The cochlear exposure allowed both the scala tympani and vestibule to be exposed. The mean ± SD minor and major distances between the cochleostomy and the meatal plane were estimated to be 2.48±0.88mm and 3.11±0.86mm, respectively. The mean distance from the cochleostomy to the round window was 8.38±1.96mm, and that to the superior petrosal sinus was 9.19±1.59mm. The mean minor and major distances between the cochleostomy and the long axis of the meatal plane from its most proximal portion were estimated to be 6.63±1.38mm and 8.29±1.43mm, respectively. The mean angle between the cochleostomy and the meatal plane was 22.54±7.400. The computed tomography of all 5 temporal bones demonstrated the insertion of the implant array from the cochlear basal turn towards its apex. Conclusion: The proposed technique for identifying the cochlear basal turn is simple and trustworthy. Additionally, it enables visualization of the scala tympani, facilitating the insertion of the cochlear implant array through this chamber
455

Referências anatômicas ao giro basal da cóclea no assoalho da fossa craniana média para o implante coclear / Anatomical references to the cochlear basal turn on the floor of the middle cranial fossa for cochlear implantation

Bittencourt, Aline Gomes 29 May 2014 (has links)
Introdução: A técnica clássica para o implante coclear é realizada por meio de mastoidectomia seguida de timpanotomia posterior. O acesso pela fossa craniana média provou ser uma alternativa valiosa, embora seja usada para o implante coclear, ainda sem normatização. Objetivo: Descrever um novo acesso pela fossa craniana média que expõe o giro basal da cóclea para o implante coclear. Métodos: Estudo anatômico de ossos temporais. Foram dissecados 50 ossos temporais. A cocleostomia foi realizada mediante um acesso via fossa craniana média, na porção mais superficial do giro basal da cóclea, usando o plano meatal e seio petroso superior como as principais referências anatômicas. Foi determinada a distância entre os pontos de referência, o ângulo entre o plano meatal e a cocleostomia, e a distância entre esta estrutura e a janela redonda. Foi realizada tomografia computadorizada em 5 dos ossos temporais utilizados neste estudo. Resultados: Em todos os 50 ossos temporais, apenas a porção mais superficial do giro basal da cóclea foi aberta e tanto as escalas timpânica como a vestibular foram visualizadas. As distâncias médias ± DP, menores e maiores, entre a cocleostomia e o plano meatal foram estimadas em 2,48±0,88mm e 3,11±0,86mm, respectivamente. A distância média da cocleostomia até a janela redonda foi de 8,38±1,96mm, e daquela até o seio petroso superior 9,19±1,59mm. As distâncias médias, menores e maiores, entre a cocleostomia e o eixo longo do plano meatal a partir da sua porção mais proximal foram estimadas em 6,63±1,38mm e 8,2±1,43mm, respectivamente. O valor médio do ângulo entre a cocleostomia e o plano meatal foi igual a 22,54±7,400. As tomografias computadorizadas demonstraram a inserção do feixe de eletrodos por meio do giro basal da cóclea até o seu ápice em todas as peças submetidas a este exame. Conclusão: A técnica proposta para identificar o giro basal da cóclea é simples e confiável. Igualmente, permite a visualização da escala timpânica e a inserção do feixe de eletrodos do implante coclear através desta câmara / Introduction: The classic technique for cochlear implantation uses mastoidectomy followed by posterior tympanotomy. The middle cranial fossa approach has proved to be a valuable alternative for cochlear implantation, although the standardization of this technique is still needed. Objectives: To describe a novel approach through the middle cranial fossa for exposing the cochlear basal turn for cochlear implantation. Materials And Methods: Anatomical temporal bone study. Fifty temporal bones were dissected. A cochleostomy was performed via a middle fossa approach on the most superficial part of the cochlear basal turn, using the meatal plane and superior petrous sinus as the main landmarks. The distance between the landmarks, the angle between the cochleostomy and the meatal plane, and the distance between this structure and the round window were measured. A computed tomography was performed on 5 of the studied temporal bones. Results: In all 50 temporal bones, only the superficial portion of the cochlear basal turn was uncovered. The cochlear exposure allowed both the scala tympani and vestibule to be exposed. The mean ± SD minor and major distances between the cochleostomy and the meatal plane were estimated to be 2.48±0.88mm and 3.11±0.86mm, respectively. The mean distance from the cochleostomy to the round window was 8.38±1.96mm, and that to the superior petrosal sinus was 9.19±1.59mm. The mean minor and major distances between the cochleostomy and the long axis of the meatal plane from its most proximal portion were estimated to be 6.63±1.38mm and 8.29±1.43mm, respectively. The mean angle between the cochleostomy and the meatal plane was 22.54±7.400. The computed tomography of all 5 temporal bones demonstrated the insertion of the implant array from the cochlear basal turn towards its apex. Conclusion: The proposed technique for identifying the cochlear basal turn is simple and trustworthy. Additionally, it enables visualization of the scala tympani, facilitating the insertion of the cochlear implant array through this chamber
456

Avaliação do trauma intracoclear causado pela inserção do feixe de eletrodos do implante coclear via janela redonda em ossos temporais / Assessment of intracochlear trauma caused by insertion of cochlear implant electrode array via round window in temporal bones

Martins, Graziela de Souza Queiroz 12 May 2014 (has links)
INTRODUÇÃO: A ampliação dos critérios de indicação para cirurgia do implante coclear e os benefícios da preservação da audição residual no pósoperatório estimularam o desenvolvimento de técnicas cirúrgicas atraumáticas. Minimizar os traumas intracocleares durante a inserção do feixe de eletrodos do implante coclear é um passo fundamental para este intuito. O objetivo deste trabalho é avaliar se o trauma intracoclear é diferente quando o feixe de eletrodos do implante coclear é inserido através do quadrante anterossuperior ou anteroinferior da membrana da janela redonda. MÉTODOS: Vinte e cinco ossos temporais frescos de cadáveres humanos foram submetidos à timpanomastoidectomia padrão. Após exposição adequada da membrana da janela redonda, em metade dos ossos o feixe de eletrodos do implante coclear foi inserido via quadrante anterossuperior da membrana da janela redonda, e na outra metade via quadrante anteroinferior. Os ossos temporais foram desidratados e embebidos em epóxi, com o feixe de eletrodos in situ. As peças foram serialmente polidas, tingidas e visualizadas por meio de estereomicroscópio para avaliar o trauma intracoclear causado pela inserção do feixe de eletrodos. As imagens foram fotografadas. RESULTADOS: Em treze ossos temporais o feixe de eletrodos do implante coclear foi inserido via quadrante anterossuperior da membrana da janela redonda, e em doze ossos via quadrante anteroinferior. Obteve-se 372 superfícies. As análises histológicas revelaram diferentes graus de traumas às estruturas intracocleares. Os resultados mostraram que a inserção do feixe de eletrodos via quadrante anterossuperior ou anteroinferior acarretam a mesma frequência de trauma intracoclear. CONCLUSÕES: A presença de trauma intracoclear e a severidade dos traumas ocorridos no tocante à inserção do feixe de eletrodos de implante coclear pelo quadrante anterossuperior e anteroinferior da membrana da janela redonda não apresentou diferença estatisticamente significativa. Observou-se, porém, maior facilidade para exposição cirúrgica do quadrante anterossuperior em relação ao quadrante anteroinferior / INTRODUCTION: The expansion of the indication criteria for cochlear implant surgery and the benefits of preserving residual hearing postoperatively have stimulated the development of atraumatic surgeries. Minimizing the intracochlear traumas during the electrodes insertion is a critical step for this aim. The objective of this study is to assess whether there is a difference in intracochlear trauma when the cochlear implant electrode array is inserted through the anterior-superior or anterior-inferior quadrants of the round window membrane. METHODS: Twenty-five fresh human temporal bones were submitted to standard tympanomastoidectomy. After adequate exposure of the round window membrane, in half of the bones the cochlear implant electrode array was inserted via anterior-superior quadrant of round window membrane and in the other half via anterior-inferior quadrant. The temporal bones were dehydrated and embedded in epoxy with the electrodes array in situ. The specimens were serially polished, stained and viewed through a stereomicroscope to assess the intracochlear trauma caused by insertion of the electrode array. Resulting images were documented. RESULTS: In thirteen temporal bones the cochlear implant electrode array was inserted via anterior-superior quadrant of round window membrane and in twelve bones via anterior-inferior quadrant. Three hundred and seventy two surfaces were obtained. Histological examinations revealed varying degrees of damage to the intracohlear structures. The results showed that the insertion of the electrode array via anterior-superior or anterior-inferior quadrant lead to the same frequency of intracochlear trauma. CONCLUSIONS: The presence of intracochlear trauma and severity of traumas regarding the insertion of cochlear implant electrode array via anterior-superior and via anterior-inferior quadrant of the round window membrane showed no statistically significant difference. However, it was observed that surgical exposure of anterior-superior quadrant was easier than surgical exposure of anterior-inferior quadrant
457

"Emissões otoacústicas produto de distorção em recém-nascidos medicados com ototóxicos" / Distortion product otoacoustic emission in newborn exposed to ototoxic

Marone, Marisa Ruggieri 22 June 2006 (has links)
INTRODUÇÃO: Os aminoglicosídeos são freqüentemente usados no berçário e podem ser tóxicos para as células ciliadas cócleo-vestibulares, especialmente para as células ciliadas externas da base da cóclea. As emissões ototacústicas produto de distorção permitem avaliar porções específicas da cóclea, antes mesmo que a sensação auditiva seja alterada, sendo ideais para análise precoce da integridade dessa estrutura auditiva, além de ser indicada para recém-nascidos por serem objetivas. O objetivo deste estudo prospectivo longitudinal é pesquisar a amplitude das emissões otoacústicas produto de distorção, causadas pelo uso de drogas ototóxicas, entre o término da administração e de 15 a 40 dias após seu uso. MÉTODOS: A população foi de recém-nascidos a termo e pré-termo provenientes de berçário e maternidade de um hospital público em Santo André, no período de julho de 2003 a setembro de 2004. A primeira avaliação ocorreu no dia da alta hospitalar. Foram avaliados três grupos: grupo controle com 33 recém-nascidos saudáveis e de termo; grupo de estudo a termo exposto a amicacina e /ou vancomicina com 19 recém-nascidos com mais de 37 semanas e grupo de estudo pré-termo exposto aos mesmos ototóxicos, com 15 recém-nascidos de 32 a 37 semanas. Os recém-nascidos não apresentavam indicadores de risco para deficiência auditiva preconizados pelo JCIH,2000 concomitante à infecção neonatal. Todos os recém-nascidos foram avaliados com idade gestacional corrigida maior que 37 semanas. As amplitudes das emissões otoacústicas dos recém-nascidos em fase de alta hospitalar foram comparadas às obtidas de 15 a 40 dias após a alta. RESULTADOS: As amplitudes das emissões otoacústicas dos recém-nascidos do grupo de estudo pré-termo foram menores que as amplitudes do grupo controle e do grupo de estudo a termo nos dois momentos de teste. As amplitudes das emissões dos recém-nascidos dos três grupos aumentaram no segundo momento de teste. As amplitudes das emissões dos recém-nascidos foram maiores na freqüência de 6.000 Hz e na orelha direita para a freqüência f2 3.000 Hz. As amplitude das emissões do grupo controle no segundo momento de teste foram semelhantes as do grupo de estudo à termo no primeiro momento da pesquisa. CONCLUSÔES: Houve aumento da amplitude das emissões otoacústicas produto de distorção desde a fase de alta até 15 a 40 dias após. A exposição a amicacina e vancomicina nas doses preconizadas pelo Neofax®, 2003/2004 não alterou as amplitudes das emissões nos recém-nascidos sem indicadores de risco concomitante à infecção neonatal. / The amynoglicosides are frequently used in nurseries and may be toxic for the cochleo-vestibular hair cells, specially for the outer cells of the cochlear base. The distortion product otoacoustic emissions allow to evaluate specific portions of the cochlea even before the hearing sensation is altered, and are ideal for the early analysis of this auditory structure integrity, besides being indicated for newborns once they are objective. The aim of this prospective longitudinal study is to research the amplitude of distortion product otoacoustic emissions caused by the ototoxic drugs use, between the end of the administration and from 15 to 40 days after its use. The population studied was composed by term and preterm newborns from a nursery and maternity of a Santo André city hospital, in the period from July 2003 to September 2004. The first evaluation occurred on the hospital discharge day. Three groups were evaluated: control group with 33 term and healthy newborns; term study group with 19 term newborns with more than 37 weeks exposed to amicacin and/or vancomycin; and preterm study group with 15 preterm newborns from 32 to 37 weeks exposed to the same ototoxic. The newborns did not present risk factors for hearing loss according to the JCIH, 2000 concomitant to the neonatal infection. All newborns were evaluated at a corrected gestational age greater than 37 weeks. The otoacoustic emissions amplitudes obtained at the hospital discharge were compared to the ones obtained from 15 to 40 days after the discharge. The results showed that the otoacoustic emissions amplitudes of the preterm study group were smaller than the amplitudes of the control group and the term study group in both moments of the test. The amplitude of the newborns’ otoacoustic emissions increased in the second moment of the test. The amplitudes were higher in the frequency of 6.000Hz and, in the right ear in the frequency f2 3.000 Hz. The otoacoustic emissions amplitudes of the control group in the second moment of the test were similar to the term study group in the first moment of the research. It was concluded that there is an increase of the distortion product otoacoustic emissions amplitude from the discharge moment until 15 to 40 days after, suggesting a maturation of the cochlear structures in the post-natal period, and that the exposure to amicacin and vancomycin on the recommended dose by Neofax®, 2003/2004 did not alter the amplitude of the emissions in the newborns without risk indicators concomitant with neonatal infection.
458

Avaliação do trauma intracoclear causado pela inserção do feixe de eletrodos do implante coclear via janela redonda em ossos temporais / Assessment of intracochlear trauma caused by insertion of cochlear implant electrode array via round window in temporal bones

Graziela de Souza Queiroz Martins 12 May 2014 (has links)
INTRODUÇÃO: A ampliação dos critérios de indicação para cirurgia do implante coclear e os benefícios da preservação da audição residual no pósoperatório estimularam o desenvolvimento de técnicas cirúrgicas atraumáticas. Minimizar os traumas intracocleares durante a inserção do feixe de eletrodos do implante coclear é um passo fundamental para este intuito. O objetivo deste trabalho é avaliar se o trauma intracoclear é diferente quando o feixe de eletrodos do implante coclear é inserido através do quadrante anterossuperior ou anteroinferior da membrana da janela redonda. MÉTODOS: Vinte e cinco ossos temporais frescos de cadáveres humanos foram submetidos à timpanomastoidectomia padrão. Após exposição adequada da membrana da janela redonda, em metade dos ossos o feixe de eletrodos do implante coclear foi inserido via quadrante anterossuperior da membrana da janela redonda, e na outra metade via quadrante anteroinferior. Os ossos temporais foram desidratados e embebidos em epóxi, com o feixe de eletrodos in situ. As peças foram serialmente polidas, tingidas e visualizadas por meio de estereomicroscópio para avaliar o trauma intracoclear causado pela inserção do feixe de eletrodos. As imagens foram fotografadas. RESULTADOS: Em treze ossos temporais o feixe de eletrodos do implante coclear foi inserido via quadrante anterossuperior da membrana da janela redonda, e em doze ossos via quadrante anteroinferior. Obteve-se 372 superfícies. As análises histológicas revelaram diferentes graus de traumas às estruturas intracocleares. Os resultados mostraram que a inserção do feixe de eletrodos via quadrante anterossuperior ou anteroinferior acarretam a mesma frequência de trauma intracoclear. CONCLUSÕES: A presença de trauma intracoclear e a severidade dos traumas ocorridos no tocante à inserção do feixe de eletrodos de implante coclear pelo quadrante anterossuperior e anteroinferior da membrana da janela redonda não apresentou diferença estatisticamente significativa. Observou-se, porém, maior facilidade para exposição cirúrgica do quadrante anterossuperior em relação ao quadrante anteroinferior / INTRODUCTION: The expansion of the indication criteria for cochlear implant surgery and the benefits of preserving residual hearing postoperatively have stimulated the development of atraumatic surgeries. Minimizing the intracochlear traumas during the electrodes insertion is a critical step for this aim. The objective of this study is to assess whether there is a difference in intracochlear trauma when the cochlear implant electrode array is inserted through the anterior-superior or anterior-inferior quadrants of the round window membrane. METHODS: Twenty-five fresh human temporal bones were submitted to standard tympanomastoidectomy. After adequate exposure of the round window membrane, in half of the bones the cochlear implant electrode array was inserted via anterior-superior quadrant of round window membrane and in the other half via anterior-inferior quadrant. The temporal bones were dehydrated and embedded in epoxy with the electrodes array in situ. The specimens were serially polished, stained and viewed through a stereomicroscope to assess the intracochlear trauma caused by insertion of the electrode array. Resulting images were documented. RESULTS: In thirteen temporal bones the cochlear implant electrode array was inserted via anterior-superior quadrant of round window membrane and in twelve bones via anterior-inferior quadrant. Three hundred and seventy two surfaces were obtained. Histological examinations revealed varying degrees of damage to the intracohlear structures. The results showed that the insertion of the electrode array via anterior-superior or anterior-inferior quadrant lead to the same frequency of intracochlear trauma. CONCLUSIONS: The presence of intracochlear trauma and severity of traumas regarding the insertion of cochlear implant electrode array via anterior-superior and via anterior-inferior quadrant of the round window membrane showed no statistically significant difference. However, it was observed that surgical exposure of anterior-superior quadrant was easier than surgical exposure of anterior-inferior quadrant
459

"Estudo da ação do nível elevado de pressão sonora e do extrato seco de Ginkgo biloba EGb761 na citoarquitetura da cóclea de cobaias adultas" / Morphological study on the effects of high sound pressure and Ginkgo biloba EGb 761 dry extract to the cochlea cell architecture of adult guinea pigs

Silva, Nadejda Maria Avila Varginha de Moraes e 06 April 2005 (has links)
A preocupação com a exposição do Homem ao ruído excessivo data dos primórdios da civilização. Com a modernidade, os níveis de ruído têm sido crescentes não só nas atividades laborais, como também nas sociais e recreativas, levando a perda auditiva induzida por níveis de pressão sonora elevada (PAINPS) a ser considerada a segunda maior causa de surdez. Esses fatos nos levaram a realizar estudo experimental buscando avaliar o efeito do nível de pressão sonora elevada e do extrato seco de Ginkgo biloba EGb 761 na cóclea de cobaias albinas, fêmeas e adultas, pela avaliação de eventuais alterações da sua citoarquitetura, por meio de microscopia de luz e pela observação das alterações do epitélio sensorial com microscopia eletrônica de varredura / Human exposition to excessive sound levels has been a cause for preoccupation since the early stages of our civilization. In the Modern Era, sound levels have increased not only at work but also during social and leisure activities, leading the hearing loss induced by high levels of sound pressure to be considered the second most important cause of deafness. Bearing that in mind an experimental work was designed in an attempt to search for the effects of high sound pressure and Ginkgo biloba EGb 761 dry extract to the cochlea of albino adult female guinea pigs with the evaluation of cell architecture alterations by means of light microscopy and also by the evaluation of alterations to the sensory epithelium with the scanning electron microscopy (SEM) array
460

Avaliação da audição em criança de 3 a 6 anos, em creches e pré-escolas municipais, de São José do Rio Preto, São Paulo

Piatto, Vânia Belintani 18 December 1998 (has links)
Made available in DSpace on 2016-01-26T12:51:49Z (GMT). No. of bitstreams: 1 vaniapiatto_dissert.pdf: 265912 bytes, checksum: d6bd354613ca0a9752b4acad6612d8cd (MD5) Previous issue date: 1998-12-18 / The aim of this study was to evaluate the hearing and the prevalence of hearing impairment among children, in the age groups of 3 to 6 years old, from Municipal Nursery and Pre-schools of São José do Rio Preto, S.P. At first stage, audiometries in a free field were performed for screening in 103 children, both sexes in 8 Nursery and 8 Pre-schools previously selected. At second stage, the ones who presented audiometric alterations were referred to the Phonoaudiological Service of FAMERP to perform conventional pure tone audiometer. The classification of hearing impairment in relation to grade was made according to W.H.O. approaches. A male child (0.97%) was found with light grade of conductive hearing impairment in the left ear ( LE=35 dB). There was no significant difference among the ratio of hearing impairment in both sexes (p=1.00). Nine children (8.73%) showed alterations in the hearing thresholds by air conduction in 4000, 6000 and/or 8000 Hz sharp frequencies. The ratio among alterations in these frequencies was not statistically significant in both sexes (p=1.00). There is need of further studies to evaluate the result found in children with alterations in those sharp frequencies. The found prevalence of hearing impairment in this studied population can chek the need of use of prevention programs and earlier diagnosis of hearing impairments. / Este estudo teve como objetivo realizar a avaliação da audição e o levantamento da prevalência de deficiência auditiva em amostra de crianças, na faixa etária de 3 a 6 anos, em creches e pré-escolas municipais de São José do Rio Preto, etapa, em 103 crianças de ambos os sexos, na referida faixa etária, em 8 creches e 8 pré-escolas previamente selecionadas. As crianças que apresentaram alterações audiométricas na triagem, foram encaminhadas ao ambulatório de fonoaudiologia da famerp para realização de audiometria tonal convencional, em uma segunda etapa. A classificação da deficiência auditiva, em relação ao grau, foi feita segundo os critérios da oms. Foi encontrado uma criança do sexo masculino (0,97%) com deficiência auditiva condutiva de grau leve na orelha esquerda (m oe=35 db). Não houve diferença significativa entre as proporções de deficiência auditiva em ambos os auditivas, por via aérea, nas freqüências agudas de 4000, 6000 e/ ou 8000 hz. Nota de Resumo Não foi estatisticamente significante a diferença entre as proporções de alterações nas freqüências acima descritas em ambos os sexos (p=1,00). Há necessidade de posteriores estudas para avaliação do resultado encontrado em relação ás crianças com alterações nas referidas freqüências agudas. A prevalênciaencontrada de deficiência auditiva na população do estudo, pode comprovar a necessidade da implantação de programas de prevenção e diagnóstico precoce da deficiência auditiva. Unitermos: surdez- métodos de avaliação, classificação; crianças- pré-escolares; audiometria-tonal, da fala.

Page generated in 0.3276 seconds