• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 534
  • 269
  • 39
  • 39
  • 23
  • 17
  • 17
  • 17
  • 17
  • 16
  • 11
  • 10
  • 7
  • 4
  • 4
  • Tagged with
  • 1029
  • 457
  • 319
  • 246
  • 131
  • 126
  • 125
  • 115
  • 95
  • 89
  • 84
  • 81
  • 75
  • 73
  • 69
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
881

Avaliação de overdentures mandibulares com diferentes sistemas de retenção: análise fotoelástica da transmissão de tensões e efeito de carga cíclica na força de retenção / Evaluation of mandibular overdentures with different attachments systems: Photoelastic stress analysis and effect of cyclic loading on retention force

Fábio Afrânio de Aguiar Junior 01 July 2013 (has links)
O surgimento dos implantes osseointegrados melhorou a qualidade de vida de pacientes edêntulos. Seu uso favorece retenção e estabilidade, gerando maior eficiência mastigatória e conforto. O objetivo deste estudo foi avaliar manutenção da força de retenção e padrões de tensões gerados na mandíbula em overdentures confeccionadas com dois sistemas de retenção retidas por 2 ou 3 implantes. Teste de carga cíclica e análise fotoelástica de tensões foram realizados. Para o teste de carga cíclica foram utilizados modelos representativos de mandíbulas desdentadas e os grupos analisados foram: A) 2 implantes com barra clipe; B) 3 implantes com barra clipe; C) 2 implantes com barra clipe e bola/o\'ring nas extremidades; D) 3 implantes com barra clipe e bola/o\'ring nas extremidades. Cinco espécimes por grupo foram submetidos à ciclagem e 5 permaneceram imersos na máquina de ciclagem (controle). As leituras de força de retenção foram realizadas por ensaio de tração em máquina de ensaios universal antes da ciclagem e a cada 500 mil ciclos. A ciclagem foi realizada com frequência de 1,8 Hz, carga de 130 N, por 2 milhões de ciclos. Para a aplicação de carga, foram feitas pontas correspondentes à arcada antagonista unilateral posterior. Os dados obtidos foram analisados estatisticamente pelo modelo linear de efeitos mistos. Para a análise fotoelástica, foi feito um modelo mestre curvo em resina acrílica. O modelo foi preparado para conter cinco implantes, paralelos, distribuídos na região interforaminal. Grupo com 4 implantes com barra clipe e o\'rings nas extremidades foi incluído como controle. Prótese total foi confeccionada e usada em todos os grupos. A cada grupo, nova captura de retentores foi realizada. Para obtenção dos modelos fotoelásticos, foram confeccionados moldes em silicone do modelo mestre. A verificação das tensões em torno dos implantes foi realizada por meio de análise fotoelástica qualitativa de transmissão sob aplicação de carga cêntrica estática de 50 N. Diferentes tipos de pontas e locais de aplicação de carga foram usados. Os resultados demonstraram que carga cíclica influencia na perda de retenção overdentures mandibulares. Comparando grupos controle e teste, observou-se que os grupos com três implantes apresentaram maior influência da ciclagem na perda de retenção. Os sistemas de retenção estudados apresentaram comportamentos diferentes até um milhão de ciclos, após não houve diferença quanto à manutenção de retenção. Todos os grupos mantiveram retenção satisfatória ao final da ciclagem. Três implantes apresentaram maior tensão ao redor dos implantes e pouca ou nenhuma sobre o rebordo. Nos grupos com dois implantes, aplicação de carga posterior gerou tensões no rebordo alveolar e implantes. Grupos com extensões distais evidenciaram uma maior tensão ao redor dos implantes que os sem extensão. / The appearance of osseointegrated dental implants improved the quality of life of fully edentulous patients. Implants promote retention and stability, producing higher masticatory efficiency and comfort. The aim of this study was analyze the retention maintenance and the stress pattern generated by two or three implants-supported mandibular overdentures with two attachments systems. Cyclic loading test and photoelastic stress analysis were performed. For the cyclic loading test, edentulous mandibular models were used. The analyzed groups were: A) 2 implants with bar clip; B) 3 implants with bar clip; C) 2 implants with bar clip and balls/o\'rings in the extremity; D) 3 implants with bar clip and balls/o\'rings in the extremity. Five specimens per group were submitted to cyclic loading and five were kept immersed inside the test machine (control group). The measurements of retention force were performed by tensile test in a universal testing machine before cyclic loading and after each 500 thousands cycles. The cycling was performed with frequency of 1.8 Hz, loading of 130 N, up to two million cycles. For the load application, tips corresponding to posterior unilateral antagonist teeth were produced. Data were statistically analyzed by linear mixed-effects model. For the photoelastic analysis, a curved master model was produced in acrylic resin. The model contained five parallel implants, distributed in interforaminal area. A group with 4 implants splinted with bar clip and balls/o\'rings in the extremity was included as a control. Complete denture was made and used in all groups. In each group, incorporating of new attachments was performed. For the obtainment of photoelastic models, silicone impression of the master model was performed. The assessment of stress around implants was done through quantitative transmission photoelastic analysis under static centric load application of 50 N. Different sorts of tips and load application places were used. The results showed that cyclic load influences the retention loss of mandibular overdentures. Comparing test and control groups, it was observed that groups with three implants showed higher influence of cyclic loading in retention loss. The studied attachments systems showed different behaviors up to one million cycles, after that there was not difference in the maintenance of retention. All groups had satisfactory retention at the end of cycling. Groups with three implants showed higher stress around implants and lower or none on alveolar ridge. In groups with two implants, load application on posterior area caused stress on alveolar ridge and implants. Groups with distal extensions demonstrated higher stress around implants than groups without extension.
882

Estudo piloto do impacto da terapia antiproliferativa com everolimus administrado por via oral na diminuição de reestenose após implante de stent auto-expansível de nitinol para tratamento de lesões oclusivas da artéria femoral superficial / Pilot study of the impact of antiproliferative therapy with everolimus administered orally in the reduction of restenosis after implantation of selfexpandable nitinol stent for treatment of occlusive lesions of the superficial femoral artery

Luis Ramon Virgen Carrillo 15 June 2009 (has links)
INTRODUÇÃO: A implantação de stent auto-expansível de nitinol para o tratamento das lesões oclusivas femoro-poplíteas tem sido associado com maus resultados a longo prazo. O everolimus administrado via oral para inibir reestenoses do stent foi investigado recentemente em animais com bons resultados, porém sua segurança e eficácia não têm sido estudada em seres humanos. O propósito deste estudo piloto foi avaliar o impacto da terapia antiproliferativa com everolimus administrado via oral por 28 dias na diminuição de reestenose após implante de stent auto-expansível de nitinol para tratamento de lesões oclusivas da artéria femoral superficial. MÉTODOS E RESULTADOS: Trinta e quatro pacientes foram recrutados para este estudo randomizado, prospectivo. O grupo que recebeu everolimus via oral foi constituído por 15 pacientes e o grupo que não recebeu medicação composto por 19 pacientes. As características basais e do procedimento foram similares entre os dois grupos. Todos os pacientes tinham isquemia crônica do membro inferior e oclusão da artéria femoral superficial (média da lesão de 83,14 mm no grupo sem medicação e 105 mm no grupo everolimus). O objetivo primário do estudo foi a redução da porcentagem média do diâmetro da reestenose intra-stent após seis meses da angioplastia avaliada por angiografia quantitativa. A porcentagem média do diâmetro das reestenoses foi 46,9% no grupo tratado com everolimus e 44,5% no grupo que não recebeu a medicação (p=0,81). Não foram observados efeitos colaterais graves nos grupos. No acompanhamento clínico aos 24 meses não houve diferenças significativas entre os grupos em relação a eventos clínicos. A patência primária, primária assistida e secundária em 24 meses, foi 42%, 74% e 79% no grupo sem medicação e 27%, 73% e 73% no grupo tratado com everolimus. CONCLUSÃO: O everolimus via oral por 28 dias em doses altas é seguro e bem tolerado, com baixo índice de efeitos colaterais, porém não é eficaz na redução da porcentagem média do diâmetro da reestenose intra-stent em pacientes com implante de stents auto-expansíveis de nitinol nas lesões oclusivas complexas da artéria femoral superficial. / INTRODUCTION: The implantation of a self-expanding of nitinol stent in the treatment of femoropopliteal occlusive lesions has been associated with a poor outcome in a long term setting. Everolimus administered orally to inhibit restenosis of the stent was investigated recently in animals with good results, but its safety and efficacy has not been studied in humans. The purpose of this pilot study was to evaluate the impact of antiproliferative therapy with everolimus administered orally for 28 days in the reduction of restenosis after implantation of self-expandable nitinol stent for treatment of occlusive lesions of the superficial femoral artery. METHODS AND RESULTS: Thirty-four patients were recruited for this randomized, prospective study. The group that received oral Everolimus was consisted of 15 patients and the group that received no medication was 19 patients. The baseline characteristics and procedure were similar in both groups. All the patients had chronic lower limb ischemia and occlusion of the superficial femoral artery (mean of the lesion of 83.14 mm in the group without medication and 105 mm in the everolimus group). The primary objective of the study was to evaluate the reduction of the average percentage of the diameter of in-stent restenosis six months after angioplasty assessed by quantitative angiography. The in-stent mean percent diameter stenosis was 46.9% in the group treated with everolimus and 44.5% in the group that received no medication (p = 0.81). There were no serious side effects seen in either group in the clinical follow up at 24 months. There was no significant difference between groups in relation to clinical events. The primary patency, assisted primary and secondary in 24 months was 42%, 74% and 79% in the group without medication and 27%, 73% and 73% in the group treated with Everolimus. CONCLUSION: Everolimus administered orally for 28 consecutive days to stent implantation in high doses proves to be safe and well tolerated, with low rate of side effects, but it is not effective in reducing the average percentage of diameter of in-stent restenosis in patients with implantation of self-expandable nitinol stent in complex occlusive lesions of the superficial femoral artery.
883

Concepção de proteses mioeletricos de membros superiores baseado no estudo fisiologico / Conception of upper limbs myoelectrical prosthesis based on physiological study

Vidal, Tabata 25 February 2008 (has links)
Orientador: Helder Anibal Hermini / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-11T07:22:27Z (GMT). No. of bitstreams: 1 Vidal_Tabata_M.pdf: 5227439 bytes, checksum: 003d20540fa55512408c2b363171f23c (MD5) Previous issue date: 2008 / Resumo: O objetivo deste trabalho foi revisar na literatura os desenvolvimentos da aplicação das tecnologias envolvidas em automação dedicadas às próteses mioelétricas de membros superiores, desde os primeiros trabalhos implementados no período pós-Segunda Guerra Mundial até as soluções tecnológicas atualmente utilizadas. O conceito de prótese mioelétrica envolve a aquisição e tratamento do sinal mioelétrico de um membro residual que é usado para acionar um atuador que ativará a ferramenta terminal. Objetivando a elaboração de uma solução compatível e aplicável harmonicamente ao sistema orgânico, foram realizados estudos da anatomia, da fisiologia articular dos membros superiores, da natureza e características do sinal mioelétrico, além das tecnologias envolvidas para a concepção de protótipos mecatrônicos, tais como técnicas de CAD-CAE-CAM e a geração de circuitos eletrônicos dedicados à coleta e tratamento de sinais mioelétricos. Para validar o desenvolvimento teórico, três protótipos da ferramenta terminal foram confeccionados, sendo testados em nível de bancada / Abstract: The goal of this work was to review the specialized literature for the development of technological applications connected with automation of myoelectrical prosthesis of upper limbs throughout the years, from World War 2 post-war solutions to the technology currently applied. The concept of myoelectrical prosthesis presupposes implies the acquisition and treatment of the myoelectrical signal of a residual limb which is used to start an actuator, which in turn activates the terminal tool. Aiming at encountering a solution that could be both compatible and harmoniously applicable to the human body, the author engaged in studying anatomy, upper limbs articular physiology, the nature and characteristics of the myoelectrical signal in addition to the technologies utilized to conceive mechatronic prototypes, i.e. CAD-CAE-CAM and the creation of dedicated electronic circuits to collect and process the myoelectrical signals. To validate the theoretical foundation of this project, three prototypes of terminal tools were manufactured and bench-tested. / Mestrado / Mecanica dos Sólidos e Projeto Mecanico / Mestre em Engenharia Mecânica
884

Análise do comportamento de conduto valvado de pericárdio bovino tratado pelo glutaraldeído, implantado em posição aórtica de ovinos / Performance analysis of the glutaraldehyde treated bovine pericardium valved conduit, implanted in the aortic position in ovines

Josalmir José Melo do Amaral 17 December 2009 (has links)
A necessidade de cirurgia para substituição da aorta ascendente e valva aórtica com reimplante coronariano em grupos especiais de pacientes onde a anticoagulação é indesejável, como nos idosos, é crescente nos últimos anos. Este estudo objetiva desenvolver e avaliar em modelo animal o comportamento de um conduto valvado aórtico feito com pericárdio bovino tratado pelo glutaraldeído (CVAP). Para tanto, CVAPs foram implantados em 8 ovinos jovens e explantados após serem sacrificados com 150 dias de pós-operatório. Realizou-se estudo angiográfico e hemodinâmico no préoperatório e antes do explante. Ecodopplercardiogramas foram realizados nos dias 30 e 150 de pós-operatório (teste) e também em 5 ovinos não operados (controle). Após explantados, submetemos os CVAPs à avaliação macroscópica, radiológica e histológica por microscopia óptica e eletrônica de transmissão. A análise estatística foi feita com teste não-paramétrico de Mann-Whitney, teste não-paramétrico de Wilcoxon e teste exato de Fisher. O nível de significância utilizado foi 5%. Na análise hemodinâmica houve acréscimo (p>0,05) das pressões arterial e capilar pulmonar entre os dias 0 e 150. Na análise ecodopplercardiográfica, o grupo teste apresentou valores maiores (p>0,05) dos diâmetros diastólicos e sistólicos do ventrículo esquerdo. No grupo teste entre os dias 30 e 150 houve acréscimo (p>0,05) de: peso, espessura das paredes do ventrículo esquerdo, gradiente transvalvar máximo, gradiente transvalvar médio, diâmetro diastólico do ventrículo esquerdo e decréscimo da fração de ejeção. Dois animais com endocardite podem explicar essas diferenças. A macroscopia demonstrou calcificação de grau variável, além de abaulamento na região dos seios em todos os CVAPs, sem aumento de diâmetro. A microscopia óptica revelou dados similares ao da literatura com o uso do pericárdio bovino tratado pelo glutaraldeído. A quantificação realizada com a microscopia eletrônica de transmissão mostrou percentual maior (p>0,05) de colágeno nos seios e nas cúspides e maior conteúdo hídrico na porção mais distal do CVAP. Estes dados indicam que a bioprótese aqui estudada permite a realização desse tipo de experimento no modelo proposto e que os resultados hemodinâmicos encontrados se assemelham aos parâmetros fisiológicos. / The need for replacement surgery of the ascending aorta and aortic valve with coronary reimplantation in special patient groups where anti-coagulation in undesirable, such as elderly, is increasing in the past years. This study aims to develop and evaluate the performance of an aortic valved conduit made with glutaraldehyde treated bovine pericardium (AVCP) in an animal model. Therefore, AVCPs were implanted in 8 young ovine and explanted after being euthanized at 150 days of the post-operative period. An angiographic and hemodynamic study was performed at pre-operative and prior the explant. EchoDoppercardiograms were performed at day 30 and 150 of post-operative (test) as well as in 5 non-operated on ovines (control). Following the explant, AVCPs were submitted to a macroscopical, radiological and histological evaluation by optic and electronic transmission microscopy. A statistics analysis was performed with a Mann-Whitneys nonparametric test, Wilcoxons non-parametric test and Fishers exact test. The significance level used was 5%. In the hemodynamic analysis an increase (p>0,05) of arterial and pulmonary capillary pressure occurred between day 0 and 150. In the echoDoppercardiographic analysis, the test group presented higher values (p>0,05) in the diastolic and systolic diameters of the left ventricle. In the test group, between day 30 and 150, occurred an increase (p>0,05) of weight, thickness of the left ventricle walls, maximum transvalvar gradient, medium transvalvar gradient, left ventricle diastolic diameter and a decrease in the ejection function. Two animals with endocarditis could explain those differences. Macroscopy showed a calcification in variable degrees besides a bulging of the sinus region in all AVCPs, without an increase of diameter. Optic microscopy revealed data similar to literature with the use of glutaraldehyde treated bovine pericadium. The quantification performed by electronic transmission microscopy showed a higher percentage (p>0,05) of collagen in sinus and cusps, and a higher watery content in the most distal portion of the AVCP. These data indicate that the bioprosthesis hereby studied allows the performance of this kind of experiment in the proposed model and that the hemodynamic outcomes found are similar to physiological parameters.
885

Desajuste Marginal de Infra-estruturas metálicas de próteses fixas sobre implantes considerando tipos de pilares, materiais e solda a laser / Marginal misfit of metallic structures of total fixed implant supported prosthesis considering abutments, material and laser welding

PEREIRA, Richard Esteves 24 March 2005 (has links)
Made available in DSpace on 2014-07-29T15:21:57Z (GMT). No. of bitstreams: 1 pre textuais richard esteves pereira.pdf: 111431 bytes, checksum: fed09c5e1bc065f1fe26c77537645e5e (MD5) Previous issue date: 2005-03-24 / The adaptation precision of metallic structures to implant abutments is a very questionable subject and the scientific literature lacks about the alloy that shows an adaptation closer to the ideal. This study had the proposal of: evaluating the vertical marginal misfit levels (in &#956;m) using a digital microscope of one-piece and after laser welding metallic structures of total fixed implant supported prosthesis casted in Nickel-Chrome, Nickel-Chrome-Titanium-Molibidenium and Palladium-Silver alloys and commercially pure Titanium, over two different kinds of abutments and, also, associate the misfit results observed at the one-piece structures phase with the data obtained after the laser welding treatment. After the fabrication of two master models, 40 pre-fabricated copings for both Estheticone and Micro-Unit type abutments were used at the survey. Eight metallic structures were casted with Ni-Cr, Ni-Cr-Ti-Mo, Pd-Ag and Ti-c.p., being two structures for each alloy. The vertical misfit values concerning the relation of the metallic structures and implant abutments from all alloys and on both stages one-piece and after laser welding were tabulated and then submitted to statistical tests. The values were exposed to the ANOVA and the significant statistic means were compared by the Tukey test considering a 5% significance value (p<0.05), as well as the standard deviation. The results evidenced that the one-piece structures showed misfit, but the mean values did not present statistic significant differences. The material (alloys) analysis showed that the Ti-c.p. did not show discrepant mean values, but the same did not occur with the other alloys. The comparison between all alloys showed no significant statistical differences, and, the Pd-Ag alloy (control group) showed the higher misfit mean values at the one-piece phase. The relation between the one-piece and after laser welding phases showed the presence of statistic significant values, based on the mean values (onepiece= 0.0953 &#956;m / laser welding=0.0452 &#956;m) and the marginal vertical misfit after laser welding appeared significantly decreased. / A precisão da adaptação das infra-estruturas sobre pilares de implantes é objeto de inúmeros questionamentos e a literatura ainda é carente em relação à liga que possa apresentar adaptação próxima do ideal. Assim, esta pesquisa teve como propósitos: avaliar os níveis de desajustes marginais verticais (em &#956;m) por meio de microscópio mensurador digital das infra-estruturas metálicas em monobloco e após soldagem a laser de próteses totais fixas fundidas em ligas de Níquel-Cromo, Níquel-Cromo-Titânio-Molibidênio, Paládio-Prata e Titânio Comercialmente Puro assentadas sobre dois tipos diferentes de pilares de implantes e, ainda, correlacionar os resultados obtidos dos níveis de desajustes das infra-estruturas monobloco com os das infra-estruturas pós-soldagem (a laser). A partir de dois modelos-mestre, foram enceradas 40 amostras sobre copings pré-fabricados de pilares de implantes tipo Estheticone e Micro-Unit (Conexão Sistema de Prótese-SP). Obteve-se oito infra-estruturas metálicas a partir da fundição das ligas Ni-Cr, Ni-Cr-Ti-Mo, Pd-Ag e Ti-c.p., sendo duas infraestruturas para cada liga. Os valores correspondentes às leituras das distâncias verticais (em !m) da relação infra-estruturas metálicas e pilares de implantes de todas as amostras das diferentes ligas metálicas utilizadas e das etapas monobloco e soldagem a laser foram tabulados e, em seguida, aplicado os testes estatísticos. Os valores foram sujeitos à análise de variância e as médias com diferenças estatísticas significativas foram comparadas pelo teste de Tukey com nível de significância 5% (p<0,05), bem como o desvio padrão. Os resultados evidenciaram que nas infra-estruturas em monobloco (sem solda), houve a presença de desajuste, porém os valores médios não apresentaram diferenças estatísticas significativas. Na avaliação do material empregado (ligas) verificou-se que as infra-estruturas em Ti-c.p. não apresentaram valores médios discrepantes, o que não ocorreu com as infra-estruturas obtidas com as demais ligas. Na comparação de todas as ligas utilizadas, os seus valores médios não apresentaram diferenças estatísticas significativas e a liga de Pd-Ag (Grupo Controle) foi a que apresentou valor médio de maior desajuste nas estruturas em monobloco. Na correlação das infra-estruturas monobloco e pós-soldagem (a laser), evidenciou-se a existência de diferenças estatísticas significativas, baseado nos valores médios (monobloco 0,0953&#956;m / solda a laser 0,0452&#956;m), sendo o desajuste marginal vertical para a infra-estrutura com solda a laser, significativamente menor.
886

Avaliação da microestrutura óssea de sítios implantares e fatores relacionados às alterações no nível ósseo marginal e estabilidade de implantes dentários: estudo clínico prospectivo / Assessment of microstructure of jawbone sites and factors related to the changes on marginal bone level and dental implant stability: prospective clinical study

Dias, Danilo Rocha 15 July 2013 (has links)
Submitted by Jaqueline Silva (jtas29@gmail.com) on 2014-12-12T17:49:23Z No. of bitstreams: 1 Tese-Danilo Rocha Dias-2013.pdf: 12690993 bytes, checksum: 8af178ce9d242439a10d9aafdd18a329 (MD5) / Rejected by Jaqueline Silva (jtas29@gmail.com), reason: on 2014-12-12T17:49:32Z (GMT) / Submitted by Jaqueline Silva (jtas29@gmail.com) on 2014-12-12T19:43:01Z No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Tese-Danilo Rocha Dias-2013.pdf: 12690993 bytes, checksum: 8af178ce9d242439a10d9aafdd18a329 (MD5) / Approved for entry into archive by Jaqueline Silva (jtas29@gmail.com) on 2014-12-16T09:25:37Z (GMT) No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Tese-Danilo Rocha Dias-2013.pdf: 12690993 bytes, checksum: 8af178ce9d242439a10d9aafdd18a329 (MD5) / Made available in DSpace on 2014-12-16T09:25:37Z (GMT). No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Tese-Danilo Rocha Dias-2013.pdf: 12690993 bytes, checksum: 8af178ce9d242439a10d9aafdd18a329 (MD5) Previous issue date: 2013-07-15 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPq / Bone characteristics influence surgical/prosthetic planning of implant treatment, but it is not clear their influence on longitudinal outcomes. This study aimed to investigate the association between jawbone microstructure and changes on marginal bone level (MBL) and implant stability (IS) after loading, in a 1-year follow-up. Forty-one volunteers received 97 dental implants, installed in bone sites classified from 1 to 4, according to Leckholm & Zarb (1985). Cortical bone thickness was measured on computed tomography images. Histomorphometric and microtomographic analyses were performed in bone specimens obtained by using a trephine bur, at first drilling. Peak insertion torque (PIT) and implant stability quotient (ISQ) measured by resonance frequency analysis (RFA) were registered at implant insertion. Periapical radiographs were standardized to measure the MBL, and were taken at three moments, when the ISQ was also measured: at uncovering stage, at loading and at 1-year follow-up. Agreement analysis between histomorphometry and microcomputed tomography (microCT) showed that these methods are complementary, but not interchangeably. Association tests revealed that ISQ changes were not affected by MBL changes. Bone type 4 (according L&Z) presented higher changes on ISQ, especially during osseointegration. Microstructure parameters (histomorphometric and microCT parameters) and cortical thickness did not influence ISQ changes and MBL changes. These results suggest that bone characteristics influence primary implant stability, but do not predict implant success after osseointegration. / Características do tecido ósseo influenciam o planejamento cirúrgico/protético dos implantes dentários, mas não está clara sua relação com o resultado longitudinal do tratamento com implantes. O objetivo deste estudo foi investigar a associação entre microestrutura óssea de sítios implantares da maxila e mandíbula, as alterações de nível ósseo marginal (MBL) e a estabilidade dos implantes (IS) até o período de 1 ano após a aplicação de carga oclusal. Quarenta e um pacientes receberam 97 implantes dentários, instalados em sítios ósseos classificados como tipos 1 a 4, de acordo com a classificação de Leckholm & Zarb (1985). A espessura de osso cortical foi mensurada em imagens de tomografia computadorizada. Análises microtomográficas e histomorfométricas foram realizadas em espécimes ósseos obtidos com trefina na primeira perfuração para instalação dos implantes. Torque de inserção final (PIT) e quociente de estabilidade do implante (ISQ) medido por análise de freqüência de ressonância (RFA) foram registrados durante a instalação dos implantes. Radiografias periapicais padronizadas para mensuração do MBL foram obtidas em tres momentos, quando novos registros do ISQ foram também realizados: durante a cirurgia de reabertura, na instalação das próteses e 1 ano após aplicação da carga oclusal. A análise de concordância entre os métodos de microtomografia computadorizada (microCT) e histomorfometria, mostrou que estes métodos são complementares, mas não intercambiáveis. Testes de associação mostraram que as alterações na IS não foram afetadas pelas alterações no MBL. Ossos classificados como tipo 4 apresentaram as maiores alterações da IS, principalmente durante a osseointegração. Os parâmetros microestruturais (parâmetros microtomográficos e histomorfométricos) e a espessura de cortical não influenciaram as alterações de IS e do MBL. Estes resultados sugerem que as características do sítio ósseo influenciam a estabilidade primária, mas não são preditores do sucesso dos implantes após a osseointegração.
887

Estudo da viabilidade de fabricação de um tubo para construção de uma prótese de membro inferior em composito híbrido epóxi carbono-vidro / Viability of hybrid epoxi carbon-glass composite pipe manufacture for use in lower limb prosthesis

Guilherme Wolf Lebrão 01 March 2007 (has links)
Neste trabalho propôs-se a construção de um tubo de material compósito híbrido, com fibra de vidro e fibra de carbono, para utilização como prolongador de prótese de membro inferior a serem fabricadas pela AACD - Associação de Assistência à Criança Deficiente. O objetivo é avaliar as solicitações da prótese para otimizar custo e reduzir a massa. Fez-se inicialmente um levantamento das propriedades dos materiais comerciais utilizados para a fabricação do prolongador para referenciar o desenvolvimento do componente da prótese. Utilizou-se modelagem por elementos finitos para otimizar o componente em função dos esforços biomecânicos a que a prótese é submetida. Nesta modelagem, estudaram-se várias disposições, quantidade e material das camadas de forma a atender às solicitações e minimizar os custos. O levantamento bibliográfico permitiu encontrar uma rota de menor custo para a fabricação de compósito que utiliza um processo de transferência de resina auxiliado a vácuo e pré-formados de vidro e carbono. Como referência, foi fabricado um componente pelo processo de bobinagem filamentar que produz materiais compósitos de qualidade reconhecida. O processo de moldagem por transferência de resina assistido à vácuo, apesar de ter alguns insumos importados, pela sua simplicidade pode ser realizado na própria AACD e se mostrou capaz de obter componentes com custo que viabiliza sua produção sem grandes investimentos em equipamentos. Apesar da redução de algumas das propriedades em relação à peça de referência, o tubo apresentou vantagens na redução de massa e na absorção de impacto. / In this work it was considered a construction of a pipe of hybrid composite material, with carbon and glass fibre, for use as prosthesis extension of inferior member to be manufactured for the Associação de Assistência à Criança Deficiente AACD. The objective is to evaluate the requests of prosthesis to optimize cost and to reduce weight. A survey of the properties of the commercial materials commonly used for the manufacture extension became initially a reference to the development of the final component. A finite element modeling was used to optimize the component in the biomechanics function related to the efforts which the prosthesis is submitted. In this modeling some disposals and numbers of layers, amount and material have been studied to take care of the requests and to minimize the cost. A bibliographical survey allowed finding a shipper route for the manufacture of composite that uses a process of vacuum assisted resin transfer molding and preforms of glass with carbon. As reference, a component was produced using filament winding process to compare the quality of the obtained composite pipe. The process, although to have some imported feed-stock, can be proper carried out by AACD and if it showed capable to produce components with cost that makes possible its production internally. Despite the reduction of some of the properties in relation to the reference part, the component presented advantages such as weight reduction and the impact absorption.
888

\"Estudo prospectivo dos parâmetros periodontais e peri-implantares dos pilares que recebem prótese dento-implanto-suportada\" / Prospective study of periodontal and peri-implant parameters of the pillars receiving an implant supported dental prosthesis

Vicente José Muratore de Lima 18 September 2006 (has links)
Desde a introdução dos implantes na Odontologia, controvérsias tem havido acerca da propriedade de conectar os implantes a dentes em próteses fixas. Os implantes osseointegrados não apresentam nenhum ligamento periodontal e são mais firmemente ancorados ao osso. A diferença apresentada nesta ancoragem tem levantado preocupações acerca de o implante osseointegrado, por sua firme fixação ao osso, apresentar pouca flexibilidade para dividir as cargas funcionais com os dentes conectados. O presente estudo teve como propósito acompanhar prospectivamente os parâmetros periodontais ? índice gengival, índice de sangramento, profundidade de sondagem e perda de inserção entre o dente pilar de uma prótese dento-implanto-suportada com o dente colateral do mesmo paciente, e também os parâmetros peri-implantares dos implantes que suportam estas próteses - índice gengival; índice de sangramento; profundidade de sondagem e perda de inserção. Para verificar a perda de inserção foi utilizado o recurso da subtração radiográfica da região em que a prótese foi instalada, com tomadas radiográficas efetuadas no momento da instalação da prótese, decorridos seis meses e após 12 meses de uso, com o objetivo de verificar a ocorrência, ou não, de alteração do suporte ósseo peri-implantar. Foram selecionados 12 pacientes com estado de saúde normal, apresentando área posterior de mandíbula edêntula onde estava indicada a reabilitação protética por meio de prótese fixa unindo dente a implante. Estes foram tratados com implante de um estágio de 10 mm padrão da Straumann (ITI), que apresenta um pescoço polido de 2.8mm, onde a porção do implante que permanece intra-óssea apresenta uma superfície tratada, com diâmetro de 4.1mm. O implante foi instalado no espaço onde se localizaria o retentor mais distal da futura prótese parcial fixa, seguindo o protocolo. As radiografias digitais obtidas foram avaliadas num software de subtração radiográfica, Matrox Inspector versão oito, para verificar a alteração da variação de densidade óptica e contraste das radiografias quando superpostas, sendo os valores observados no implante comparados com os critérios de sucessos , amplamente abordados nos estudos verificados. Todos os implantes instalados nos pacientes osseointegraram, não houve registro de alteração óssea ao redor dos mesmos e nos dentes pilares das próteses em avaliações feitas após seis meses e 12 meses. As próteses continuaram clinicamente em excelente estado após 12 meses de avaliação nas análises clínicas e radiográficas. Ainda, de acordo com o teste de Sinais de Postos de ilcoxon, concluiu-se estatisticamente que não houve diferença nos parâmetros peri-implantares de cada paciente durante os períodos analisados (zero, seis meses e 12 meses), bem como quando comparados com os respectivos dentes colaterais. / Since the introduction of implants in Dentistry, controversies have arisen about the possibility of connecting implants to teeth in fixed prostheses. Osseointegrated implants do no present any periodontal ligature and are more firmly anchored to the bone. The difference presented by this type of anchorage has led to some concern about the limited flexibility of the osseointegrated implant to share the functional loads with the connected teeth. This study intended to follow-up prospectively the periodontal parameters bleeding index, probing depth between the pillar tooth of an implant supported prosthesis with one control tooth of the same patient and also the implants that support theses prostheses. That is why subtraction radiography of the region in which the prosthesis was placed was used, with radiographs taken at prosthesis placement, after six months and one year of use to verify if the periimplant osseous support had or had not undergone changes. Twelve patients with normal health conditions were selected who presented a posterior area edentulous jaw where a prosthetic rehabilitation by a fixed prosthesis joining tooth to implant was indicated. Patients were treated with an implant of one stage of 10mm standard Straumann (ITI) with a 2.8 mm polished neck, in which the remaining intraosseous portion of the implant has a treated surface of 4.1 mm diameter. The implant was placed in the space where according to the protocol, the more distal retainer of the future fixed partial prosthesis would be located. Digital radiographs were assessed with a subtraction radiography software Matrox Inspector version eight, to corroborate the change of contrast in the radiographs when superimposed, with values observed in the implant compared with the success criteria , widely mentioned in surveyed studies. All implants placed in patients became osseointegrated. There was no record of bone change around them and in the dental pillars of the prostheses at the one year follow-up. Prostheses continue to be in excellent conditions after the one year follow-up based upon clinical and radiographic analyses. Furthermore, in accordance with the Wilcoxon test of matched pairs and signed rank, it was concluded that there was no statistical difference between each group of each patient during the time period analyzed (baseline and one year) as well as when the pillars were compared to their respective controls.
889

Área velofaríngea e escape de ar nasal nas condições com e sem prótese de palato / Velopharyngeal area and nasal air emission in the conditions with and without a palatal prosthesis

Cristianne Chiquto Netto 18 November 2015 (has links)
Introdução: Embora a avaliação perceptivo-auditiva seja reconhecida como padrão ouro na avaliação clínica da fala de pacientes com fissura palatina e/ou disfunção velofaríngea (DVF), ela pode ser influenciada por inúmeros fatores, dada a sua subjetividade. A avaliação instrumental, como a técnica fluxo-pressão, pode complementar os achados de fala e da função velofaríngea em indivíduos que utilizam prótese de palato com obturador faríngeo para o tratamento da DVF. Objetivos: Descrever e comparar os resultados das medidas da área velofaríngea, por meio da técnica fluxo-pressão, e do julgamento da ocorrência do EAN durante a repetição de palavras com a consoante p e da emissão da palavra papai, durante a realização do Teste de Emissão de Ar Nasal (TEAN), nas condições com e sem prótese de palato e verificar a relação entre a ocorrência do EAN e a classificação da função velofaríngea, nas condições com (CP) e sem (SP) prótese de palato. Material e Métodos: Foi realizado um estudo observacional transversal de uma amostra de conveniência de 94 pacientes com diagnóstico de insuficiência velofaríngea que utilizavam prótese de palato com obturador faríngeo. A classificação do tipo de função velofaríngea (adequada, adequada-marginal, marginal-inadequada e inadequada) foi realizada a partir da medida da área velofaríngea obtida pela técnica fluxo-pressão, durante a produção da consoante p inserida na sílaba pa. Foram coletados dos prontuários dos pacientes os resultados do julgamento da ocorrência (presença/ausência) do EAN durante a repetição de palavras com p e da emissão da palavra papai do TEAN, nas condições sem e com prótese de palato. Resultados: A medida da área velofaríngea e o julgamento da ocorrência do EAN mostraram-se significativamente menores na condição CP. Entretanto, a prótese conseguiu eliminar o EAN em 63,9% dos pacientes, quando se toma a emissão de palavras com a consoante p na avaliação articulatória para comparação, e eliminá-lo em 50% deles quando se toma a emissão da palavra papai do TEAN. Com a prótese, 56,4% pacientes apresentaram função velofaríngea adequada e 43,6% função velofaríngea diferente da adequada (adequada-marginal = 5,3%, marginal-inadequada = 5,3%, inadequada = 33%). Conclusões: As medidas da área velofaríngea obtidas por meio da técnica fluxopressão diminuem significativamente quando o paciente faz uso da prótese (condição com prótese), revelando que a prótese pode melhorar a função velofaríngea para a fala; embora a ocorrência do escape de ar nasal (EAN) na produção da consoante p demonstre ser menor com a prótese, tanto no julgamento pela modalidade auditiva quanto pela visual, a modalidade visual parece ser mais sensível para identificar a ocorrência do escape;o EAN demonstrou ter relação direta com a função velofaríngea, uma vez que apresentou-se ausente em uma função velofaríngea adequada (condição com prótese) e presente em uma função velofaríngea inadequada (condição sem prótese). Contudo, esta relação pode estar susceptível à interferência de muitos fatores que podem influenciar positivamente ou negativamente a ocorrência do EAN na função velofaríngea. / Introduction: Although perceptual judgement is recognized to be the gold standard for clinical speech evaluation of cleft palate and/or velopharyngeal dysfunction (VPD) patients, it can be influenced by a number of factors due to its subjectivity. Instrumental assessment such as pressure-flow technique can provide additional information related to speech and velopharyngeal dysfunction findings in individuals adapted to palatal speech device with obturator pharyngeal bulb for treatment of VPD Objectives: Describe and compare the results of velopharyngeal area measurements by using pressure-flow technique and the judgment of the occurrence of air nasal emission (NAE) during repetition of words containing the p consonant and utterance of the word papai in the Test of Nasal Air Emission (TNAE), in conditions with and without palatal speech device as well as to analyze the relation between NAE and velopharyngeal dysfunction ratings in conditions with and without palatal speech device.Method: A retrospective study of samples including 94 patients with diagnosis of velopharyngeal insufficiency wearing palatal prostheses with pharyngeal bulb was performed. Velopharyngeal function was rated (adequate, marginal-adequate, marginal-inadequate and inadequate) in according to velopharyngeal measurements obtained from aerodynamic evaluation during the production of p consonant in the segment pa. The results of NAE occurrence judgement (present/absent) during the repetition of words with p and utterance of papai in the TNAE were collected from the patients´s recordings, in the conditions with and without prosthesis. Results: Velopharyngeal area measurements and NAE occurrence judgement were significantly lower in the with-prosthesis condition. However, speech prosthesis was able to eliminate NAE in 63.9% of the patients, when considering utterances of words with p in articulatory evaluation as comparison, and managed to eliminate it by 50% of them with regard to the word papai in the TEAN. With the speech device, 56.4% of patients demonstrated adequate velopharyngeal function and 43.6% showed velopharyngeal ratings different of the adequate one (marginal adequate = 5.3%, marginal inadequate = 5.3% and inadequate = 33%).Conclusions: The measures of velopharyngeal area obtained byusing pressure-flow technique decreased significantly when the patient uses prosthesis (condition with prosthesis), revealing that the prosthetic device can improve velopharyngeal function for the speech. Although the occurrence of nasal air flow (EAN) in the production of the consonant p presents to be lower with prosthesis, either in the hearing judgement as in the visual one, the latter seems to be more sensible to identify the occurrence of flow. Nasal air flow (EAN) demonstrated to have a direct relation with the velopharyngeal function for it was absent in an adequate velopharyngeal function (condition with prosthesis) and present in an inadequate velopharyngeal function (condition without prosthesis). Nevertheless, this relation may be susceptible to the interference of many factors that may positively or negatively influence the occurrence of EAN in the velopharyngeal function.
890

Estudo de dois sistemas de reabilitação com implantes submetidos à ativação imediata: análise clínica, radiográfica e da estabilidade, por frequência de ressonância / Study of two rehabilitation systems with dental implants submitted to immediate loading: clinical and radiographic evaluations, and stability using resonance frequency analysis

Eduardo Antonio Ayub 28 August 2007 (has links)
Avaliou-se o comportamento biomecânico, quanto à área de estabilidade protética, extensão de cantilever e estabilidade por análise freqüência de ressonância (AFR); parâmetros clínicos: índice de placa (IP), índice de sangramento (IS), supuração, distância da plataforma do implante-margem da mucosa (DPM), profundidade de sondagem (PS), nível de inserção (NI), sangramento à sondagem (SS), largura (LM), espessura (EM) da mucosa e análise radiográfica, em dois sistemas de reabilitações implanto-suportadas. Foram instalados 104 implantes, submetidos à ativação imediata, em 26 pacientes, divididos em dois grupos: A (n= 16, All-on-4®-Nobel Biocare) e B (n=10, Neopronto®-Neodent). As próteses foram instaladas em tempo médio de 32h. (T0), e controles realizados em seis (T6), doze (T12) e 24 meses (T24). Como resultado, a taxa de sucesso foi de 100% para o grupo A e 90% para o grupo B para implantes e próteses. Diferenças significantes (p<0,05) foram apresentadas entre o cantilever posterior 10,96mm e 18,81mm e o braço de resistência (BR) 13,87mm e 5,50mm, respectivamente para os grupos A e B. A área de estabilidade, no grupo A foi de 373,5mm2 e no B de 112,8mm2; a média da AFR (em ISQ) do grupo A T0= 68,62; T6=64,40; T12=67,07; T24=66,53 e do grupo B T0= 68,37; T6=66,29; T12=67,09; T24=67,10, com diferenças (p<0,05) entre os tempos (grupo A) e posição dos implantes (grupo B). O IP no grupo A=1,0 e 0,7; grupo B=0,6 e 0,9, o IS (0,7), supuração (ausente) e SS (presença) no grupo A=50% e 37,9%; grupo B=70,1 e 52,1%, no controle de 12 e 24 meses, não mostraram diferenças estatísticas entre os grupos. As médias (em mm) da LM para o grupo A (2,05 e 2,21) e B (2,29 e 2,40) e EM grupo A (1,53 e 1,56) e B (1,31 e 1,43), DPM do grupo A (2,54e 2,52) e B (0,18mm e -0,12mm), PS grupo A (3,52 e 3,52) e B (3,52 e 4,0), NI grupo A (0,98 e 0,99) e B (3,05 e 3,57) e perda óssea grupo A (0,45mm e 0,23mm ) grupo B(0,66mm e 0,22mm), respectivamente para 12 e 24 meses, apresentaram diferenças estatísticas entre os controles. Concluindo-se que 1- O grupo A apresentou área de estabilidade e extensão de cantilever anterior e posterior, com comportamento biomecânico mais favorável do que no grupo B; 2- A estabilidade primária e secundária (AFR) foi diferente entre os tempos (grupo A) e posição dos implantes (grupo B), mas semelhantes entre os grupos; 3- Os parâmetros clínicos de índice de placa, sangramento marginal, supuração, profundidade de sondagem (exceto para os períodos de controle no grupo B), sangramento a sondagem, largura e espessura de mucosa ceratinizada foram semelhantes entre os grupos; 4- A distância da plataforma do implante-margem da mucosa foi maior no grupo A e o nível de inserção foi maior no grupo B; 5- A perda na altura da crista óssea foi semelhante entre os grupos; 6- A perda óssea foi menor nos implantes anteriores do que nos posteriores, nos grupos. / Two implant-supported rehabilitation systems were evaluated considering their biomechanical behavior, the area of prosthetic stability, cantilever extensions, stability using resonance frequency analysis (RFA) and clinical parameters, such as: modified plaque index (PI), modified bleeding index (BI), suppuration, distance between the implant shoulder and the mucosal margin (DIM), probing pocket depth (PD), probing attachment level (PAL), bleeding on probing (BP), thickness (TM) width (WM) of keratinized mucosa and radiographic analysis. One hundred and four implants had been installed in twenty six patients, submitted to immediate loading and divided into two groups: A (n=16, All-on-4®-Nobel Biocare) e B (n=10, Neopronto®-Neodent). The prosthesis had been installed in average time of 32h (T0), and controls made in (T6), 12 (T12) and 24 months (T24). As result, the success rate was 100% for the group A and 90% for the group B for both implants and prosthesis. Significant differences (p<0,05) 10,96mm and 18,81mm had been presented between posterior cantilever and the resistance arm (RA) 13,87mm and 5,50mm, respectively for the groups A and B. The stability area, in the group A was of 373,5mm2 and in B of 112,8mm2; the average of RFA (in ISQ) of the group A T0= 68,62; T6=64,40; T12=67,07; T24=66,53 and of the group B T0= 68,37; T6=66,29; T12=67,09; T24=67,10, with differences (p<0,05) between the periods (Group A) and implant position (Group B). The PI in group A was of 1,0 and 0,7 and 0,6 and 0,9 for group B, o BI (0,7), suppuration (absent), DP (presence) in group A=50% and 37,9%; group B=70,1 and 52,1%, in the control of 12 and 24 months, did not present statistical differences between the groups. The average (in mm) of WM for the group A (2,05 and 2,21) and B (2,29 and 2,40) and TM group A (1,53 and 1,56) and B (1,31 and 1,43), DIM of group A (2,54 and 2,52) and B (0,18mm and -0,12mm), DP group.

Page generated in 0.0678 seconds