901 |
Prótese parcial fixa em pacientes com fissura labiopalatina / Fixed partial prosthesis in patients with cleft lip and palateMariana Gelmini 18 November 2011 (has links)
Introdução: A ausência do incisivo lateral superior é freqüente em indivíduos com fissuras que envolvem o rebordo alveolar. As próteses parciais fixas convencionais, apesar de se tratar de procedimento não conservativo devido ao desgaste dos dentes adjacentes à fissura, podem oferecer resultados funcional e estético satisfatórios. Objetivos: Avaliar a estética da prótese e do sorriso após reabilitação com prótese parcial fixa na área da fissura, avaliar clinicamente as condições biológicas do periodonto de proteção na área correspondente à prótese e analisar o grau de satisfação dos pacientes após tratamento. Material e Métodos: Foram selecionados 40 pacientes, de ambos os gêneros, com fissura transforame incisivo e pré-forame incisivo unilateral completa, reabilitados com prótese parcial fixa na área do incisivo lateral superior ausente. Esses foram fotografados, para posterior análise por três grupos de examinadores, que classificaram a estética das próteses como agradável, aceitável e desagradável. Questionários e escala analógica visual foram utilizados para avaliar o grau de satisfação dos pacientes. Para análise estatística foram obtidos valores médios, mediana e desvio padrão e utilizados coeficiente Kappa conforme caracterizado por Landis e Koch (1977), teste de Kruskal Wallis e coeficiente de Spearman, adotando-se nível de significância 5%. Resultados: A fissura transforame incisivo unilateral correspondeu a 62,5% dos casos. Não houve diferença estatisticamente significante entre os grupos de examinadores, que consideraram prótese esteticamente aceitável e a concordância interjuízes foi considerada de moderada a substancial. Para os pacientes, a estética da prótese foi considerada satisfatória para 65% e aceitável para 22,5%. Conclusão: A maioria dos casos clínicos foi considerada prótese esteticamente aceitável, sendo que as próteses devem ser melhoradas no que diz respeito à curvatura incisal e tamanho das coroas. A ausência de papila gengival e sua reposição artificial foram observadas na maioria dos casos clínicos. A maioria dos pacientes considerou a prótese satisfatória em relação à estética e também em relação à estética do sorriso; mais estudos tornam-se necessários para se alcançar excelência no tratamento dos pacientes com fissuras. / Introduction: The absence of the lateral incisor is frequent in individuals with clefts involving the alveolar crest. The conventional prosthesis fixed partial , despite the fact that isn´t a conservative procedure, may offer results functional and aesthetic satisfactory. Objectives: To evaluate the aesthetics of the prosthesis and the smile after rehabilitation with prosthesis fixed partial in the area of the cleft, to evaluate clinically the biological conditions of the periodontium of protection in the area corresponding to the prosthesis installed and analyze the degree of patient satisfaction after treatment. Material and Methods: The sample included 40 patients of both genders, with complete unilateral cleft lip and palate, rehabilitated with partial prosthesis sets in the area of the lateral incisor absent. These patients were photographed for later analysis by groups of examiners, the prostheses of the patients were classified as aesthetically pleasing, aesthetically acceptable and aesthetically unpleasant. Questionnaires and visual analog scale were used to assess the degree of satisfaction of the patients after treatment received. For the statistical analysis the average values, median and standard deviation was obtained and by the use Kappa coefficient in agreement with Landis and Koch (1977), Kruskal Wallis Test and Spearman coefficient, with a 5% significance level adopted. Results: The unilateral cleft lip and palate accounted for 62.5% of cases. There was no statistically significant difference between the groups of examiners, was identified in all the cases aesthetically acceptable prosthesis, and the agreement of interjudges was considered moderate to substancial. For patients, the treatment was satisfactory in 65% of the cases, while22.5% considered acceptable. Conclusion: Most clinical cases was considered aesthetically acceptable prostheses with the dentures should be improved with respect to the curvature and size of incisal crowns. The absence of gingival papilla and its artificial replacement were observed in most clinical cases. Most patients considered satisfactory prosthesis in relation to aesthetics and also in relation to aesthetics of the smile, but do not consider acceptable in relation to aesthetic of the prosthesis, more studies are needed to achieved excellence in the treatment gives patients.
|
902 |
Avaliação in vitro das interfaces dos implantes Cone Morse e Hexágono Interno / In vitro evaluation of the interfaces of the Morse Taper implants and Internal hexagon implants.Roberta Pires Dias Brosco 29 January 2014 (has links)
Objetivo: Considerando que a precisão na adaptação do implante ao intermediário transmucoso é fator importante para a longevidade da prótese e que os sistemas de implantes possuem origens diversas na sua fabricação, nos propusemos a verificar a infiltração da bactéria Enterococcus faecalis na interface entre intermediário transmucoso e implantes do tipo Cone Morse e Hexágono Interno no sistema Neodent . Material e Método: A amostra foi composta por 20 implantes do tipo Cone Morse com Index Protético, 20 implantes Titamax Cone Morse e 20 implantes de Hexágono Interno e 20 intermediários transmucosos do tipo Munhão Universal CM Exact, 20 Munhão Universal em corpo único de 3,3 x 5,5 mm e 20 Munhão Universal II Plus com Parafuso. Com o auxílio da Micropipeta o Inóculo foi aspirado, imediatamente após, inserido no interior do implante que se encontrava estático na placa do Dispositivo desenvolvido para este experimento. Os intermediários foram então conectados e apertados com chave digital própria, em seguida, foi dado o torque ao parafuso do intermediário de acordo com as recomendações do fabricante. Após o torque o conjunto, implante-intermediário foi removido da placa do Dispositivo com pinça de titânio e inserido dentro do tubo de ensaio que continha o meio de cultura estéril. Diante do conhecimento da área interna de cada implante, o volume do Inóculo a ser utilizado foi determinado em 1L. Todos os tubos contendo os conjuntos foram numerados e incubados a 37oC por um período de 14 dias. Foi realizado acompanhamento diário para verificação da possível passagem de bactérias do interior do implante para o caldo. O indicativo da passagem de bactéria para o meio foi a turvação do meio de cultura (caldo BHI). Decorrido os 14 dias de observação, os dados foram tabulados e submetidos à Análise de Variância (ANOVA) com nível de significância de 5%, quando detectada diferença estatística, os valores foram submetidos ao Teste de Tuckey para comparações múltiplas. Resultados: O Teste de Tukey evidenciou que houve diferença estatisticamente significante entre o grupo de implantes Cone Morse, Cone Morse Índex e Hexágono Interno, onde o grupo de implantes Cone Morse diferiu estatisticamente do grupo Cone Morse Índex e também do grupo de implantes de Hexágono Interno. O grupo de implantes Cone Morse Índex não diferiu estatisticamente do grupo de implantes de Hexágono Interno, porém o grupo Cone Morse Índex presentou os melhores resultados. / Objective: Whereas the accuracy adaptation of the implant abutment is an important factor for the longevity of the prosthesis, and implant systems have diverse backgrounds in its manufacture, we set out to verify the infiltration of Enterococcus faecalis bacteria at the interface between the abutment and transmucosal implants of Morse Taper and Internal Hex of Neodent system. Material and Methods: The sample consisted of 20 Morse Taper implants, 20 Titamax Morse Taper implants, 20 Internal Hexagon implants and 20 transmucosal Exact CM Universal Post abutment, 20 Universal Post 3 in one body , 3 x 5.5mm and 20 Universal Post II Plus with Screw . With the aid of a micropipette the inoculum was aspirated, immediately thereafter, inserted into the implant that was in the static device board developed for this experiment. The abutments were then connected and tightened to own digital key, then the torque was given to the screw of the abutment according to the manufacturer\'s recommendations. After the torque, deploy abutment was removed from the plate clamp device of titanium and inserted into a test tube containing sterile culture. According to the internal area of each implant, the inoculum size was determined to be 1L. All the tubes were numbered and incubated at 37 ° C for a period of 14 days. Daily monitoring to check the possible passage of bacteria into the interior of the implant broth was carried out. The indication of the passage of bacteria was turbidity of the culture (BHI). Upon expiry of the 14 days of observation, the data were tabulated and an analysis of variance (ANOVA) with a significance level of 5 % was done. The values were submitted to Tukey test for multiple comparisons. Results: The Tukey test showed a statistically significant difference between the group of Morse Taper implants, Cone Morse Index and Internal Hex, where the group of implants differed from Morse Taper, Morse Taper Index group and also the group of Internal Hexagon implants. The group of Morse Taper implants Index did not differ statistically from the group of Internal hexagon implants, but Morse Taper Index group showed the best results
|
903 |
Material didático multimídia sobre o tratamento da disfunção velofaríngea por meio de obturador faríngeo / Pedro Xavier Araujo Campoverde 06 July 2017 (has links)
A falta de informação dos profissionais da área da Saúde, principalmente os de Odontologia, quanto à indicação do obturador faríngeo (OF) e do processo de sua confecção limita as possibilidades de se ampliar o tratamento da disfunção velofaríngea (DVF) em pacientes com fissura palatina e, consequentemente, as possibilidades da melhora de fala para estes pacientes. Objetivos: 1) Desenvolver um material multimídia (vídeo) sobre o uso do OF para o tratamento da DVF; 2) Avaliar o conhecimento de alunos de 4º de Odontologia, antes e após o acesso ao material. Material e Métodos: O estudo foi dividido em duas fases: 1) elaboração do material em mídia eletrônica, incluindo o planejamento e desenvolvimento do roteiro, a seleção dos participantes e o desenvolvimento de um questionário com 17 questões do tipo Falso ou Verdadeiro para avaliação do material pelos alunos; 2) apresentação do material para os alunos e resposta ao questionário. Participaram do estudo 31 alunos do 4º ano de Odontologia da FOB/USP, após terem assinado o Termo de Consentimento Livre e Esclarecido. Os alunos responderam às questões do questionário, antes de assistirem ao vídeo e imediatamente após o terem assistido. Todo o processo ocorreu em sala de aula, demorando 35 minutos. Resultados: O vídeo pronto e editado teve duração de 6 minutos. Os alunos acertaram uma média de 83% das questões antes de assistirem ao vídeo, aumentando os acertos para 95% após o acesso. Dentre estes acertos, os referentes às perguntas 1, 4 e 8 mostraram significância estatística. Conclusão: O material multimídia elaborado teve um impacto positivo no entendimento dos alunos de Odontologia quanto ao tratamento da DVF em indivíduos com fissura palatina, por meio de obturador faríngeo. / The lack of information among health professionals, especially dentists about the indication of pharyngeal obturator prosthesis and the process of its fabrication, restrict these professionals to the possibility of expanding the knowledge of velopharyngeal dysfunction (VPD) treatment in patients with cleft palate, and consequently the possibilities of speech improvement for these patients. Objectives: 1) Develop a multimedia material (video) about the use of pharyngeal obturator for VPD treatment; 2) Evaluate the knowledge of dentistry students, before and after access to the material. Methods: The study was divided in two phases: 1) elaboration of the material in an electronic media, including planning and development of script, selection of participants, and development of a questionnaire with 17 True or False questions to evaluate the material by the students; 2) presentation of the material to the students and questionnaire reply. Thirty one senior dentistry undergraduate students from FOB/USP participated of this study after signing the Consent Form. The students answered the 17 questions before watching the video and immediately after watching it. The entire process lasted 35 minutes in their own classroom at the university. Results: The edited video lasted 6 minutes. The students scored an average of 83% of the questions before watching the video, increasing the hits to 95% after watching it. The difference between the answers for the questions #1, #4, and #8 was statistically significant. Conclusion: The video had a positive impact on students understanding regarding to the VPD treatment in cleft palate patients by means of pharyngeal obturator.
|
904 |
Custo direto do implante por cateter de bioprótese valvar aórtica nas diferentes vias de acesso / Direct cost of transcatheter aortic valve implantation in the different access routesEliana Bittar 31 March 2017 (has links)
Introdução: Uma nova alternativa de tratamento foi desenvolvida, o Implante por Cateter de Bioprótese Valvar Aórtica (TAVI, em inglês, Transcatheter Aortic Valve Implantation), indicado para os pacientes portadores de estenose aórtica grave com várias comorbidades, considerados inoperáveis pelo tratamento cirúrgico convencional. O TAVI ainda não foi incorporado ao rol de políticas de saúde do Brasil pelo Sistema Único de Saúde (SUS), tampouco pela Agência Nacional de Saúde Suplementar (ANS), pois há escassez de evidências científicas fundamentadas em análise econômica do procedimento que relatem os resultados e o custo a longo prazo em comparação à cirurgia convencional. Objetivo: Identificar o custo direto médio do implante por cateter de bioprótese valvar aórtica, verificar se há alteração significativa de custo nas diferentes vias de acesso utilizadas e identificar os fatores preditores que possam elevar o custo do procedimento. Método: Trata-se de uma pesquisa com abordagens quantitativa, exploratória, descritiva, transversal, retrospectiva e documental, realizada em um hospital da Secretaria de Estado de Saúde de São Paulo (SES-SP), da Administração Direta, especializado no tratamento de doenças cardiovasculares de alta complexidade. A população do estudo correspondeu aos procedimentos eletivos do TAVI, desde a inauguração da sala híbrida, em março de 2012, até agosto de 2015, totalizando 108 procedimentos, sendo 92 por via transfemoral, 8 por via transapical e 8 por via transaórtica. Resultados: O custo direto médio dos procedimentos TAVI nas três vias totalizou R$ 82.230,94. Por via transfemoral, esse custo médio foi de R$ 82.826,38; por via transaórtica, R$ 79.440,91; e por via transapical, R$ 78.173,41. O total de material e medicamento/solução representou, por via transfemoral, 91,89% do total do custo direto médio do procedimento TAVI; por via transapical, 91,81%; e por via transaórtica, 90,69%, e o custo fixo com a válvula transcateter, no valor de R$ 65 mil, representou 78,47% sobre o custo total do procedimento TAVI, por via transfemoral; 83,14%, por via transapical; e 81,82%, por via transaórtica. O Teste Kruskal-Wallis Teste das Variáveis Contínuas apresentou diferença estatisticamente significativa entre as vias de acesso. No custo total do procedimento TAVI, o Teste de Bonferroni mostrou diferença na associação entre as vias transfemoral e transapical. No entanto, na associação com a via transaórtica, não apresentou diferença estatisticamente significativa. Os fatores preditores que elevaram o custo do procedimento TAVI foram: vias de acesso, duração do procedimento, material de hemodinâmica, medicamento/solução, material de consumo, material de perfusão, total de material e medicamento/solução, recursos humanos, gases medicinais, depreciação e energia. A segunda válvula foi a única variável referente às intercorrências no Centro Cirúrgico que elevou o custo do procedimento. A média de idade dos pacientes com indicação ao TAVI foi de 81,50 ±6,96 anos. Conclusão: O TAVI é um avanço a ser discutido e acompanhado, havendo a necessidade de reforçar novas pesquisas que avaliem os benefícios do tratamento com base nos resultados e custos, a fim de auxiliar na tomada de decisão para incorporação desse tratamento para o público-alvo, melhorando a qualidade de vida dos pacientes e proporcionando a integração destes novamente às atividades diárias. / Introduction: A new treatment alternative has been developed, the Transcatheter Aortic Valve Implantation (TAVI), indicated for patients with severe aortic stenosis with various comorbidities deemed inoperable by conventional surgical treatment. TAVI has not yet been incorporated into the Brazilian health policies by the Public Health System (SUS), or by the National Supplementary Health Agency (ANS), because there is a shortage of scientific evidence based on an economic analysis of the procedure that reports the results and the long-term costs compared to conventional surgery. Objective: To identify the average direct cost of the transcatheter aortic valve implantation, to verify if there is significant change of cost in the different access routes used, and to identify predictive factors that could increase the cost of the procedure. Method: This is a study with quantitative, exploratory, descriptive, transversal, retrospective, and documentary approaches, carried out in a hospital of the State Department of Health of São Paulo (SES-SP), of the Direct Administration, specialized in the treatment of high-complexity cardiovascular diseases. The study population corresponded to TAVI elective procedures, from the inauguration of the hybrid room, in March 2012, up to August 2015, totaling 108 procedures, of which 92 were transfemoral, 8 were transapical, and 8 were transaortic. Results: The average direct cost of the TAVI procedures in the three routes totaled R$ 82,230.94. Transfemorally, this average cost was R$ 82,826.38; through the transaortic route, R$ 79,440.91; and through the transapical route, R$ 78,173.41. The total material and medication / solution represented 91.89% of the total average direct cost of the TAVI procedure through the transfemoral route; 91.81% through the transapical route; and 90.69% through the transaortic route, and the fixed cost with the transcatheter valve, in the amount of R$ 65,000.00, represented 78.47% of the total cost of the TAVI procedure through the transfemoral route; 83.14%, through the transapical route; and 81.82% through the transaortic route. The Kruskal-Wallis Test Continuous Variables Test showed a statistically significant difference among the access routes. In the total cost of the TAVI procedure, the Bonferroni Test showed a difference in the association between the transfemoral and transapical routes. However, in the association with the transaortic route, there was no statistically significant difference. Predictive factors that increased the cost of the TAVI procedure were: access routes, length of procedure, hemodynamic material, drug / solution, consumption material, infusion material, total material and medicine/solution, human resources, medical gas, depreciation and energy. The second valve was the only variable related to the complications in the or that increased the cost of the procedure. The mean age of patients with TAVI was 81.50 ± 6.96 years. Conclusion: TAVI is an advance to be discussed and monitored, and there is a need to encourage new studies that evaluate the benefits of treatment based on the results and costs, in order to assist in the decision making for the incorporation of this treatment into its population, improving the quality of life of patients and providing once again their integration into daily activities.
|
905 |
Avaliação da eficácia da esterização de furadeiras elétricas domésticas utilizadas em cirurgias ortopédicas / Evaluation of the efficacy of the sterilization of ordinary electric drills for orthopedic surgeriesVania Regina Goveia 20 December 2007 (has links)
Estima-se que há mais de 50 anos, as furadeiras elétricas (FE) têm sido empregadas em cirurgias ortopédicas nos hospitais brasileiros para a perfuração óssea. Trata-se de equipamento elétrico, termossensível, não indicado para uso cirúrgico, não avaliado anteriormente quanto à eficácia da esterilização, suspeitando-se de risco potencial para infecções do sítio cirúrgico ou relacionadas a próteses ortopédicas. Os objetivos desse estudo foram: avaliar a carga microbiana de FE do uso cirúrgico e avaliar a eficácia da esterilização por óxido de etileno (ETO) de FE novas intencionalmente contaminadas. Trata-se de pesquisa experimental, laboratorial, randomizada e aplicada desenvolvida no laboratório de pesquisas experimentais da Escola de Enfermagem da Universidade de São Paulo. O trabalho foi realizado em duas fases. As condições assépticas foram rigorosamente seguidas para o controle das variáveis. Quinze FE analisadas na fase I, tiveram distribuição aleatória e cega, capturadas em um centro cirúrgico de um hospital escola. Foram cultivados: o ar gerado pelo motor e alíquotas de 10 µL do lavado das superfícies interna e externa das FE. Ainda nessa fase foi realizado um controle positivo onde uma FE foi contaminada com Serratia marcescens e um teste do método de filtração por membrana de porosidade de 0,45 µm com uma FE limpa, onde as membranas que filtraram diferentes quantidades do lavado foram cultivadas. Na fase II foram analisadas 22 FE e três perfuradores de osso (PO). Dezesseis FE constituíram o grupo experimental (GE), seis o controle positivo (GCP) e três PO constituíram o controle negativo (GCN). Todos os equipamentos previamente limpos e esterilizados foram submetidos à contaminação com esporos de Bacillus atrophaeus. As FE do GCP foram analisadas após a exposição ao contaminante, furadeiras do GE e perfuradores do GCN foram submetidos à limpeza e esterilização por ETO antes de serem analisados. Foram cultivados: ar gerado pelo motor e membrana filtrante após a filtração do lavado das superfícies interna e externa dos equipamentos. Foram realizadas coloração e microscopia: Gram para culturas positivas; Wirtz-Conklin para culturas positivas com bacilos Gram positivos. Os resultados mostraram que a carga microbiana de FE do uso cirúrgico é baixa e foi detectada em duas ocasiões no cultivo do ar, 1 ufc/FE e em uma ocasião no cultivo de alíquotas do lavado, 9 ufc/FE. O controle positivo realizado com Serratia marcescens comprovou a sensibilidade do método para amostras contendo alta concentração de contaminantes. O método filtração por membrana mostrou-se sensível para detectar baixa contaminação das FE, sendo o eleito para o teste de esterilidade. Os controles positivos apresentaram crescimento do microrganismo contaminante, comprovando a aderência ao material. Os controles negativos não apresentaram crescimento. Das 16 FE do GE, duas apresentaram crescimento sendo cada uma delas de 1ufc do contaminante inicial respectivamente no cultivo do ar e no cultivo da membrana. Foi comprovada a eficiência de 99,99999881% do processo de esterilização por ETO, com a probabilidade de sobrevivência de 1,19 x 10-8. Nas condições do desenvolvimento do experimento, a eficácia da esterilização das FE por ETO foi comprovada / Electric drills have been used to perform orthopedic surgeries in Brazilian hospitals for almost more than 50 years. This electric equipment is heat-sensitive and it is not appropriate to use in surgical procedures. Until now the efficacy of sterilization of this item had been not evaluated as a potential risk for the occurrence of surgical site infection or infection related to orthopedic prosthesis. The objectives of this study were to evaluate the bioburden of the used electric drills and to evaluate the sterility of the new electric drills contaminated artificially. It is an experimental and randomized study performed in the research laboratory of the Nursing School of the São Paulo University. The study was performed in two phases following rigorous aseptic techniques to control the variables. In the first phase fifteen electric drills were taken in the operating room of the university hospital and included in the study using aleatory and blind methods. Cultures were performed from the air produced by the drill engine and the aliquots of 10µL of the rinsed water from the internal and external surface of the electric drill. One electric drill was included as a positive control and was contaminated with Serratia marcescens. A membrane filter with porous of 0,45 µm were cultured after had been exposed to the rinsed water from the internal and external surface of the clean electric drill. In the second phase were analyzed twenty two electric drills and three orthopedic drilling machines. Sixteen electric drills were included in the experimental group, six were the positive control group and three orthopedic drilling machines in the negative control group. All the equipments previously cleaned and sterilized were submitted to the contamination with Bacillus atrophaeus. The electric drills included in the positive control group were analyzed after exposed to the contaminant and the electric drills of the experimental group and orthopedic drills included in the negative control group were submitted to clean and ethylene oxide sterilization before to start the analysis. The air produced by the drill engine and the membrane filter after exposed to the rinsed water of the internal and external surface of the electric drill were cultured. It was performed Gram microscopy and Wirtz-Conklin to Gram positive bacilli. The results showed low bioburden in the electric drills in two episodes. So, 1 cfu/electric drill was found in one episode of the air culture and 9 cfu/electric drill in one episode of culture of the aliquot. The positive control with Serratia marcescens demonstrated the sensibility of the method in samples with high concentration of contaminants. The method of membrane filtration showed sensible to detect low bioburden of the electric drills. So it is elected for the sterility test. The positive controls showed the growth of the contaminant microrganism demonstrating the adherence to the material surface. The negative controls did not show growth. Two of the sixteen electric drills included in the experimental group showed each one growth of 1cfu of the initial contaminant of the air and the membrane cultures respectively. So the efficiency of the sterilization process was 99,99999881% and the probability of find survivor was 1,19 x 10-8. In these conditions the study demonstrates that the efficacy of the ethylene oxide sterilization was proved
|
906 |
Prótese auditiva ativa cirurgicamente implantável de orelha média para reabilitação auditiva em pacientes com atresia aural congênita bilateral: técnica cirúrgica e resultado audiológica / An implantable active middle ear prosthesis for auditory rehabilitation in patients with bilateral congenital aural atresia: surgical technique and results audiologicalLuiz Fernando Manzoni Lourençone 23 August 2018 (has links)
Introdução: A atresia aural congênita refere-se a um espectro de deformidades da orelha presentes ao nascimento que envolve algum grau de falha no desenvolvimento do canal auditivo externo, e, muitas vezes, da membrana timpânica e dos ossículos da orelha média. Uma das consequências da atresia aural congênita é a perda auditiva condutiva que deve ser tratada precocemente a fim de evitar complicações. O uso do Vibrant soundbridge no tratamento da perda auditiva tem propiciado a melhora da audição destes pacientes em serviços de todo o mundo. Objetivo: Sistematizar e descrever a técnica cirúrgica do Vibrant soundbridge em pacientes com atresia aural congênita bilateral e descrever os resultados das avaliações audiológicas após a realização da cirurgia. Método: Doze pacientes com atresia aural congênita bilateral realizaram a cirurgia do Vibrant soundbridge e foram submetidos às avaliações audiológicas em dois momentos: antes e após seis meses da realização da cirurgia. As avaliações realizadas foram: audiometria tonal limiar, audiometria em campo livre, reconhecimento auditivo de palavras no silêncio (lista de monossílabos) e limiar de reconhecimento de sentença, e relação sinal/ruído (HINT - Brasil). Foi feita a análise dos dados por meio das estatísticas descritivas e inferenciais. Resultados: O protocolo cirúrgico utilizado para implantação do dispositivo Vibrant soundbridge em pacientes com atresia aural congênita bilateral foi descrito. Não ocorreram complicações intra ou pós-operatórias. Os limiares auditivos em campo livre melhoraram de 53,5 dB para 27,2 dB após seis meses de uso do Vibrant soundbridge (p < 0,001). O reconhecimento auditivo de palavras monossílabas melhorou significantemente após a cirurgia (de 61,0% para 91,3%). No HINT, também foi encontrada melhora estatisticamente significante (p < 0,001) do limiar de reconhecimento de sentenças que passou de 67,1dB para 45,9 dB e a média da relação sinal/ruído (S/R) melhorou de 5,6 dB para 1,4 dB (p=0,009). Conclusões: Sistematizar a técnica cirúrgica do Vibrant soundbridge em pacientes com atresia aural congênita bilateral permitiu a realização de uma cirurgia segura, sem complicações pós-operatórias, resultando na obtenção de resultados audiológicos positivos nesta população / Introduction: Congenital aural atresia refers to a spectrum of ear deformities present at birth that involve some degree of failure in the development of the external auditory canal, and often the tympanic membrane and middle ear ossicles as well. One of the consequences of congenital aural atresia is conductive hearing loss that must be treated early to avoid complications. The use of Vibrant soundbridge(TM) for treating hearing loss has improved the hearing of these patients in practices worldwide. Objective: To systematize and describe the surgical technique for implanting the Vibrant soundbridge(TM) in patients with bilateral congenital aural atresia and to describe the results of postoperative audiological evaluations. Method: Twelve patients with bilateral congenital aural atresia underwent Vibrant soundbridge(TM) implantation surgery and audiological evaluations at two instances: before and 6 months after surgery. The evaluations included threshold tonal audiometry, free field audiometry, auditory word recognition in silence (list of monosyllables), sentence recognition threshold, and signal to noise ratio (HINT - Brazil). Data were analyzed through descriptive and inferential statistical methods. Results: The surgical protocol used for implantation of the Vibrant soundbridge(TM) device in patients with bilateral congenital aural atresia was described. There were no intraoperative or postoperative complications. The free-field auditory thresholds improved from 53.5 dB to 27.2 dB after 6 months of Vibrant soundbridge(TM) use (p < 0.001). The auditory recognition of monosyllable words improved significantly after surgery (from 61.0% to 91.3%). In HINT, we also found a statistically significant improvement (p < 0.001) in the sentence recommencement threshold from 67.1 dB to 45.9 dB and the mean S/R ratio improved from 5.6 dB to 1.4 dB (p = 0.009). Conclusions: Systematization of the Vibrant soundbridge(TM) surgical technique in patients with bilateral congenital aural atresia allowed safe surgery without postoperative complications and resulted in positive audiological results in the test population
|
907 |
Comparação entre a punção primária e secundária da prótese fonatória traqueoesofágica: uma revisão sistemática / Comparison between primary and secondary phonatory tracheoesophageal puncture prosthesis: a systematic reviewJosé Carlos Barauna Neto 18 November 2016 (has links)
Introdução: Desde as primeiras laringectomias totais, a perda da voz natural é considerada uma das principais consequências. Durante décadas, têm-se desenvolvido mecanismos e próteses na tentativa de conseguir a reabilitação vocal com taxas variáveis de sucesso. Após a introdução das punções traqueoesofágicas e passagem da prótese fonatória, esta passou a ser o método de escolha. A passagem primária (PTE1) traz a vantagem da utilização mais precoce da voz, no entanto, existe a preocupação com o risco aumentado de complicações. Objetivo: Comparar as complicações e o sucesso na reabilitação vocal de pacientes submetidos à reabilitação por punção tráqueoesofágica (PTE) primária e secundária por meio de uma revisão sistemática. Métodos: Foram incluídos estudos que compararam a eficácia da PTE primária e secundária quanto a reabilitação fonatória e taxas de complicações. Foi consultada a base de dados eletrônica MedLine via Pubmed, Scielo, Lilacs, Cochrane e Websco até junho de 2016, utilizando-se a estratégia de busca com descritores os \"laryngectomy AND (tracheoesophageal puncture OR punctures)\", \"(laryngeal neoplasms OR laryngectomy) AND (pharyngocutaneous fistula OR cutaneous fístula)\" no PubMed e EMBASE; e \"(neoplasias laríngeas OR laringectomia) AND (fistula cutânea)\" no MEDLINE. Resultados: Para o vazamento ao redor da prótese, o grupo PTE1 apresentou índice maior que o PTE2 (22,5% vs. 6,9%), p=0,03. Houve maior ocorrência de infecção de ferida operatória (9,1% vs. 3,9%) e para estenose de traqueostoma (8,5% vs. 4,5%) no grupo PTE1 em relação ao PTE2, porém, sem significado estatístico. A avaliação da qualidade de voz não foi possível devido à heterogeneidade dos estudos. Conclusão: Há redução do risco de vazamento ao redor da prótese de aproximadamente 10% no grupo de pacientes submetidos à punção traqueoesofágica secundária / Introduction: Since the first total laryngectomy was performed, the loss of natural voice has been considered one of its main consequences. For decades, mechanisms and prosthesis have been developed in an attempt to achieve speech rehabilitation with varying rates of success. After the introduction of the tracheoesophageal puncture and placement of the voice prosthesis, this has become the method of choice. The primary passage (TEP1) has the advantage of earlier use of the voice; however, there is the concern about the possible increased risk of complications. Objective: To compare the complications and success in speech rehabilitation of patients undergoing rehabilitation after primary and secondary tracheoesophageal puncture (TEP1 and TEP2) through a systematic review. Methods: The literature survey included research in MedLine, Scielo, Lilacs, Cochrane and Websco until June, 2016 considering the descriptors \"laryngectomy AND (tracheoesophageal puncture OR punctures)\", \"(laryngeal neoplasms OR laryngectomy) AND (pharyngocutaneous fistula OR cutaneous fistula)\" in PubMed and EMBASE; and \"(neoplasias laríngeas OR laringectomia) AND (fístula cutânea)\" in MedLine. The intervention analyzed was rehabilitation with TEP1 and TEP2 regarding complications and speech rehabilitation. Results: The rate of leakage around the prosthesis was higher in TEP1 (22.5% vs. 6.9%), p=0.03. There were higher rates of wound infection (9.1% vs. 3.9%) and tracheal stenosis (8.5% vs. 4.5%) in TEP1 group in relation to TEP2, with no statistical significance, however. The evaluation of speech quality was not possible due to the heterogeneity of the studies. Conclusion: There is a reduction of the risk of leakage around the prosthesis of approximately 10% among TEP2 patients
|
908 |
Qualidade de vida relacionada à saúde bucal de usuários de prótese total e prótese parcial removível / Oral health related quality of life in incomplete and removable partial denture wearersMESKO, Mauro Elias 02 June 2012 (has links)
Made available in DSpace on 2014-08-20T14:30:07Z (GMT). No. of bitstreams: 1
Dissertacao_mauro_mesko.pdf: 1218358 bytes, checksum: 91782e3d1bf5a72f4bbadf7935232dc0 (MD5)
Previous issue date: 2012-06-02 / Longevity increase is not directly related to quality of life. In Dentistry, it became in evidence by the fact that almost twenty-five percent of the population between 65 and 74 year-old presents a completely edentulous arch. As the elderly have a higher probability of being affected by chronic oral problems they tend to demand complex treatments. The aim of this survey was to: (i) evaluate the relationship between the Oral Health Impact Profile (OHIP-EDENT) and Geriatric Oral Health Assessment Index (GOHAI) questionnaires to assess the oral health quality of life in denture wearers, (ii) evaluate the associated factors to impairment in the oral health quality of life in elderly wearing removable dentures using the OHIP- EDENT and GOHAI. Evaluation of the oral health quality of life in complete denture and removable partial denture wearers was performed according to the World Health Organization criteria. The survey consisted of applying GOHAI and OHIP-EDENT questionnaires and a clinical examination. Questions about socioeconomic conditions were applied aiming to determine which factors have an influence in oral health related quality of life. The hypotheses tested were (1) different questionnaires would provide similar results when assessing oral health quality of life in totally or partially edentulous patients wearing prosthesis; (2) age, socioeconomic profile, type and location of the prosthesis and their stability and retention would not be associated to the oral health quality of life. The results showed that the questionnaires are different tools when both the total and adjusted values were compared. The exception was for Kennedy Class I and II removable partial dentures wearers. Mandibular complete dentures caused a higher impact in individuals quality of life, except for the removable partial denture wearers. For the patients aged 60 years old or more the questionnaires showed themselves quite different. Among the subscales, the only statistically difference was found in functional limitation and the domains food catching was the one that showed difference in the removable partial denture wearers group. Using the same questionnaires the variables age, familiar income, type of prosthesis, stability and retention of the prosthesis were evaluated. Factors associated to the 14 impact in OHRQoL were familiar income, stability and retention of the prostheses. Therefore, OHIP-EDENT and GOHAI are different tools, especially when used with individuals older than 60 years old, poor denture quality was associated to the impact in quality of life while income had influence on the results / O aumento da longevidade nem sempre está associado diretamente a uma melhora na qualidade de vida. Na Odontologia isso é evidente uma vez que quase um quarto da população entre 65 e 74 anos tem um de seus maxilares totalmente desdentados, conforme o levantamento de Saúde Bucal de 2010. Os pacientes idosos têm uma maior probabilidade de apresentarem problemas bucais crônicos e potencial demanda de tratamentos complexos. Os objetivos deste estudo foram (i) avaliar se existe correlação entre os questionários Oral Health Impact Profile for Edentulous (OHIP-EDENT) e Geriatric Oral Health Assessment Index (GOHAI) para medir qualidade de vida relacionada à saúde bucal em uma população de usuários de próteses removíveis; (ii) avaliar os fatores associados a incapacidades na qualidade de vida relacionada a saúde bucal em uma população de usuários de próteses removíveis utilizando o OHIP-EDENT e o GOHAI. Pacientes usuários de próteses removíveis atendidos nas Clínicas da Faculdade de Odontologia da UFPel foram avaliados seguindo os critérios da Organização Mundial de Saúde onde foi realizado exame intrabucal. Foram aplicados os questionários GOHAI e OHIP-EDENT, além de questões sobre condições demográficas e socioeconômicas, visando determinar se algum fator influenciaria na qualidade de vida destes indivíduos. As hipóteses testadas foram as de que: (1) os questionários apontariam resultados semelhantes na mensuração da qualidade de vida relacionada à saúde bucal em pacientes usuários de próteses removíveis; (2) os fatores idade, condição socioeconômica, tipo de prótese e localização da prótese, bem como sua retenção e estabilidade não estariam associados a incapacidades na qualidade de vida relacionada à saúde bucal. Os resultados mostraram que o OHIP-EDENT e o GOHAI são ferramentas diferentes tanto quando se comparam os resultados brutos quanto os ajustados, exceto para as próteses parciais removíveis Classes I e II de Kennedy. As próteses totais mandibulares se mostraram causadoras de maior impacto sobre a qualidade de vida dos indivíduos, porém isto não ocorreu com as
12 parciais removíveis. Para o grupo de pacientes acima dos 60 anos o OHIP-EDENT e o GOHAI mostraram resultados bastante diferentes, parecendo ser o OHIP-EDENT mais sensível. Dentre as subescalas dos dois questionários, a única que mostrou diferença estatística foi a limitação funcional, sendo o domínio que mostrou diferença a retenção alimentar nos grupos de próteses parciais removíveis. Utilizando os mesmos questionários, quando se avaliaram as variáveis idade, renda familiar, tipo de prótese e retenção e estabilidade das próteses, os fatores associados ao impacto na qualidade de vida foram: renda familiar, estabilidade e retenção. Conclui-se que o OHIP-EDENT e o GOHAI são ferramentas diferentes, principalmente para uso em pacientes acima dos 60 anos e que a qualidade da prótese está associada ao impacto na qualidade de vida, além do fator renda ter influência sobre os resultados
|
909 |
Potencial inflamatório de duas técnicas para afastamento gengival utilizadas durante procedimentos protéticos / Inflammatory potential of two techniques used for gingival retraction during restorative proceduresSARMENTO, Hugo Ramalho 18 March 2013 (has links)
Made available in DSpace on 2014-08-20T14:30:09Z (GMT). No. of bitstreams: 1
Dissertacao_hugo_ramalho.pdf: 1163967 bytes, checksum: 5735b7a46397cc9fceb1883f7a66141c (MD5)
Previous issue date: 2013-03-18 / This study was composed by two phases that evaluated two gingival displacement (GD) techniques, conventional and cordless: 1- a in vitro study which assess cytoxicity/genotoxicity, and pH of AlCl3-based agents; and 2- a randomized clinical which evaluated the efficacy of these techniques. For in vitro phase, eluates were obtained by dilution of AlCl3-based into culture medium for 1h, 4h, and 24h. pH values were measured by digital pHmeter, cytotoxicity by MTT test and genotoxicity by Micronuclei test. A crossover, double-blind, randomized clinical trial was designed to evaluate clinical, immunologic and individual factors before and after GD by two techniques, conventional (gingival cord + astringent gel) and cordless (astringent-based paste). These factors were evaluated on incisors prepared for metal-ceramic dental crowns before, 1 day post-GD and 10 day post-GD. Interleukin 1β, Interleukin 6 and Tumor Necrosis Factor α concentrations were evaluated on gingival crevicular fluid collected before (control) and 1 day post-GD. In vitro data were analyzed by two-way ANOVA and Tukey test. Clinical data were analyzed by One-way Repeated Measures ANOVA and Tukey test (immunologic factor), Friedman test (periodontal parameters), and Fisher Exact or Qui-square test (pain, stress, and unpleasant flavor during GD). All test were realized considering p<0.05. Mean pH values were statistically higher for Viscostat than Expasyl. Both astringents were non-cytotoxic at 1h. Expasyl was more cytotoxic than Viscostat at 4h and 24h. Expasyl genotoxicity was not different from control group. Neither of the two evaluated techniques resulted in worse periodontal indices. Conventional technique was statistically more stressing than cordless, and similar considering pain and unpleasant taste. GD by the both 11 treatments evaluated led to statistically higher mean concentrations of the three interleukins evaluated. Conventional GD technique resulted in the highest interleukins levels. In vitro, AlCl3-based astringents presented acceptable biological activity with no genotoxic difference between Expasyl and control group. In vivo, cordless technique was less stressful and resulted in lower cytokines levels after GD / Este estudo foi composto por duas fases que avaliaram duas técnicas para afastamento gingival (AG), convencional e sem fio: 1- um estudo in vitro que avaliou acitotoxicidade/genotoxicidade, e o pH de agentes à base de AlCl3; e 2- um ensaio clínico randomizado que avaliou a eficácia destas técnicas. Na fase in vitro, eludatos foram obtidos pela diluição dos eluates agentes à base de AlCl3 em meio de cultura por 1h, 4h e 24h. Os valores de pH foram aferidos por pHmetro digital, citotoxicidade pelo teste MTT e genotoxicidade pelo teste do Micronúcleo. Um ensaio clínico randomizado, cruzado, duplo-cego foi concebido para avaliar fatores clínicos, imunológicos e individuais antes e após AG por duas técnicas, convencional (C: fio gengival + gel adstringente) e sem fio (SF: pasta à base de adstringente). Estes fatores foram avaliados em incisivos preparados para coroas metalo-cerâmicas antes, 1 dia e 10 dias após AG. As concentrações de Interleucina 1β, Interleucina 6 e Fator de Necrose Tumoral α foram avaliadas no fluido gengival crevicular coletado antes (controle) e 1 dia após AG. Os dados do estudo in vitro foram analisados por ANOVA 2-fatores e teste de Tukey. Os dados do ensaio clínico foram analiados por ANOVA para medidas repetidas e teste de Tukey (fator imunológico), teste de Friedman (parâmetros periodontais), e Exato de Fisher ou teste Qui-quadrado (dor, estresse e sabor desagradável). Todos os testes consideraram p<0.05. Os valores médios de pH foram estatísticamente superiores para C que para SF. As técnicas não foram citotóxicas no tempo de 1h. SF foi mais citotóxica que C em 4h e 24h. A genotoxicidade SF foi semelhante à do grupo controle. Nenhuma das técnicas avaliadas resultou em piora nos indices periodontais. Atétnica C foi mais estressante 9 que a SF, e semelhantes considerando dor e sabor desagradável. AG realizado por ambas as técnicas levou a maiores concentrações médias das três citocinas avaliadas. C resultou nos maiores níveis de interleucinas. In vitro, os adstringentes apresentaram atividade biológica aceitável, sem diferença na genotoxicidade entre as técnicas. In vivo, SF foi menos estressante e resultou em menores níveis de citocinas após AG
|
910 |
Uso e necessidade de prótese dentária aos 24 anos numa coorte de nascimentos: prevalência e fatores associados / Use and Need of Prosthodontics at age 24 in a birth cohort: prevalence and associated factorsCorrea, Marcos Britto 19 February 2009 (has links)
Made available in DSpace on 2014-08-20T14:30:16Z (GMT). No. of bitstreams: 1
Dissertacao_Marcos Britto Correa.pdf: 513868 bytes, checksum: 6b1c2a81e71b671e7afec86e13b96b8a (MD5)
Previous issue date: 2009-02-19 / This study aimed to investigate the prevalence of use and needs of dental prosthesis at age 24 and determinants of needs of dental prosthesis in this population. The study was nested in a population-based birth cohort started in 1982 in Pelotas, Brazil. A representative sample of 720 young adults was evaluated. Dental examinations and interviews were performed at 15 and 24 years old. Use and need of prosthesis was the outcome. Exploratory variables included demographic and socioeconomic (at birth, 15 and 24 years old), oral health and dental service utilization patterns (at ages 15 and 24). Prevalence of outcomes was calculated and Poisson Regression was used to determine risk factors to needs of dental prosthesis. The prevalence of use and needs of dental prosthesis was 2.08% and 29.72%, respectively. Multivariable analysis showed that poorest family socioeconomic trajectory [PR= 1.56 IC95% (1.08-2.26)], lower mother s educational level at children birth (p=0.023), lower family income at children birth [RP= 1.37 (1.01-1.86)], no oral hygiene instruction by the dentist [RP=1.64 IC95% (1.11-2.41)] and caries presence (high DMFT tertile) (p<0,001) were associated with prosthetic treatment needs. The results of this study support the hypothesis that socieconomic, behavioral and clinical determinants were associated to the need of dental prosthesis / O objetivo do presente estudo foi verificar a prevalência do uso e da necessidade de prótese dentária em uma população de adultos jovens e avaliar sua associação com a trajetória econômica das famílias, as condições de saúde bucal e de utilização de serviços odontológicos ao longo da vida do indivíduo. Em 1982, todos os nascimentos hospitalares ocorridos em Pelotas foram identificados e estes indivíduos foram acompanhados por inúmeras vezes. Em 2006, uma amostra de 720 indivíduos pertencentes a esta coorte foi visitada para realização de exame bucal e aplicação de questionário incluindo questões de uso de serviços odontológicos, hábitos e comportamentos relativos à saúde bucal. Foi calculada a prevalência dos desfechos e utilizada Regressão de Poisson para estimar os fatores de risco à necessidade de prótese. A prevalência de necessidade e uso de prótese foi de 29,7% e 2,1% respectivamente. A análise multivariável mostrou que a trajetória de pobreza sempre ao longo da vida [RP= 1,56 IC95% (1,08-2,26)], a baixa escolaridade materna ao nascer (p=0,023), a baixa renda familiar ao nascimento [RP= 1,37 (1,01-1,86)], a não recepção de instrução de higiene oral por parte do dentista aos 15 anos [RP=1,64 IC95% (1,11-2,41)] e a presença de cárie pelo CPO-D (p<0,001) foram associadas à necessidade de prótese aos 24 anos. Os resultados deste estudo suportam a hipótese que fatores socioeconômicos, comportamentais e determinantes clínicos estão associados a necessidade de prótese dentária
|
Page generated in 0.067 seconds