Estudo do desajuste angular e vertical em próteses fixas implantossuportadas por meio do MEF-3DGomes, Érica Alves [UNESP] 17 September 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0
Previous issue date: 2009-09-17Bitstream added on 2014-06-13T19:44:52Z : No. of bitstreams: 1
gomes_ea_dr_araca.pdf: 12533208 bytes, checksum: 62db616b630b0f9a9807e6b24297d9e8 (MD5) / Objetivo: A análise pelo método dos elementos finitos tridimensional foi utilizada para avaliar o efeito dos desajustes angular e vertical simulado em próteses fixas implantossuportadas parafusadas de 3 elementos, na resposta biomecânica do tecido ósseo peri-implantar, implantes e componentes protéticos. Material e método: Foram confeccionados 4 modelos tridimensionais, representativos de secção mandibular direita contendo um implante na região de segundo pré-molar (2oPM) e outro na região de segundo molar (2oM) ferulizados por uma prótese metalocerâmica implantossuportada parafusada de 3 elementos, diferenciados pelo tipo de desajuste protético, gerando os grupos: GC (grupo controle) - prótese totalmente adaptada aos implantes, DAU (desajuste angular unilateral) - prótese com desajuste angular unilateral de 100μm na região mesial do 2oM, DVU (desajuste vertical unilateral) - prótese com desajuste vertical unilateral de 100μm na região mesial do 2oM e DVT (desajuste vertical total) - prótese com desajuste vertical de 100μm em toda a plataforma de assentamento da infraestrutura no 2oM. Com a utilização do programa de elementos finitos Ansys® uma força vertical total de 400N foi distribuída em 12 pontos de parada cêntrica, sendo que cada molar recebeu um carregamento total de 150N e o 2oPM de 100N, gerando mapas de tensões. Resultados: Verificou-se que a distribuição e os valores de tensões para o tecido ósseo peri-implantar foram similares para todos os grupos. Os grupos com desajustes alteraram o padrão de distribuição e elevaram a magnitude das tensões em relação ao grupo GC. No grupo DAU os maiores valores de tensões foram observados no corpo do implante e parafuso de retenção. Já nos grupos DVU e DVT elevados valores de tensões foram encontrados na plataforma de assentamento da infraestrutura... / Purpose: The three-dimensional finite element analysis was used to evaluate the effect of vertical and angular misfit in 3-piece implant-supported and screw-retained fixed prostheses on biomechanical response in peri-implant bone tissue, implants and prosthetic components. Material and method: Four three-dimensional models were fabricated to represent a right posterior mandibular section with one implant in the region of second premolar (2°PM) and other in the region of second molar (2°M). The implants were splinted by a 3- piece implant-supported metal ceramic prosthesis and differed according to the type of misfit as represented by the groups: CG (control group) - prosthesis with complete fit to the implants, UAM (unilateral angular misfit) – prosthesis presenting unilateral angular misfit of 100μm in the mesial region of the 2°M, UVM (unilateral vertical misfit) – prosthesis presenting unilateral vertical misfit of 100μm in the mesial region of the 2°M, and TVM (total vertical misfit) – prosthesis presenting total vertical misfit of 100μm in the platform of the framework in the 2°M. A vertical load of 400N was distributed and applied on 12 centric points by the software Ansys®. So, vertical loading of 150N was applied on each molar while vertical load of 100N was applied on the 2°PM. Stress maps were obtained by processing of the finite element software. Results: The stress values and distribution on peri-implant bone tissue were similar for all groups. The groups presenting misfit exhibited different distribution pattern and increased stress magnitude in comparison to the group CG. The highest stress values in group UAM were observed in the implant body and retention screw. The groups UVM and TVM exhibited high stress values in the platform of the framework... (Complete abstract click electronic access below)
|
872 |
Caracterização e propriedades das resinas acrílicas de uso odontológico : um enfoque voltado para a biossegurançaFortes, Carmen Beatriz Borges January 2007 (has links)
O Brasil, à semelhança de outros países, está envelhecendo rapidamente. Os indivíduos com mais de 60 anos compõem hoje o segmento que mais cresce em termos proporcionais, mostrando um incremento da ordem de 500%, em 40 anos. A estimativa para o ano de 2020 é de que o Brasil tenha em torno de 32 milhões de indivíduos idosos, e desta população, uma parcela significativa será parcial ou totalmente desdentada, necessitando de aparelhos protéticos. Apesar da Odontologia apresentar avanços científicos notáveis na reabilitação da saúde bucal, muitos ainda usarão estes aparelhos. Sabe-se que o uso contínuo de próteses pode propiciar o desenvolvimento da estomatite protética, cuja etiologia é multifatorial, destacando-se principalmente a má higiene bucal e da prótese, e geralmente associada à presença de Candida albicans. Desta forma, há necessidade de se propor um método de desinfecção, que se mostre eficaz, que seja seguro quanto à toxicidade, que represente baixo risco ocupacional, que seja de fácil manuseio e que não interfira nas propriedades dos materiais utilizados na confecção destes aparelhos. Portanto, a proposição deste trabalho foi avaliar a influência de dois métodos de desinfecção, nas propriedades das resinas acrílicas empregadas na confecção das próteses.As propriedades avaliadas foram: resistência e módulo de flexão, resistência ao impacto Izod, microdureza Knoop, rugosidade, massa específica e grau de inchamento, grau de conversão do monômero, temperatura de transição vítrea, sorção e solubilidade. Os corpos de prova foram confeccionados de acordo com os requisitos de cada ensaio, tanto para os grupos controle (sem tratamento), quanto para os tratados (submetidos a um dos processos de desinfecção). Os tratamentos de desinfecção consistiram de: a) irradiação com energia de microondas na potência de 840 W, durante 1 minuto; b) imersão em ácido peracético durante 5 minutos. A eficácia da desinfecção foi avaliada através de ensaios microbiológicos que consistiram em verificar o crescimento no meio de cultura e na superfície do corpo de prova de Candida albicans, após a desinfecção dos corpos de prova, previamente contaminados com uma cepa conhecida do fungo (ATCC 10231). Como as resinas acrílicas são materiais muito utilizados em todas as áreas de atuação da Odontologia, o conhecimento das suas propriedades é de interesse do cirurgião-dentista. As resinas acrílicas tipo 1 (de termopolimerização), tipo 2 (quimicamente ativada) e tipo 5 (ativada por microondas) foram avaliadas neste trabalho. Os resultados mostraram que as resinas acrílicas tipo 1 e tipo 5 apresentam valores semelhantes em todas as propriedades analisadas. A resina acrílica tipo 2 apresentou valores inferiores àqueles encontrados nas tipo 1 e 5. O ciclo de polimerização com melhores resultados foi aquele proposto pelo respectivo fabricante daresina acrílica. A presença de fibras de nylon e de corante não influenciou as propriedades da resina acrílica tipo 5. Das técnicas de desinfecção, a imersão em ácido peracético apresentou os melhores resultados para todas as propriedades avaliadas ao longo do tempo de 20 meses. Por outro lado a irradiação de microondas, a longo prazo, apresentou os piores resultados para todas as propriedades avaliadas. Ambas as técnicas de desinfecção foram eficazes do ponto de vista microbiológico. Mas, para o uso prolongado, a técnica de desinfecção com ácido peracético pode ser recomendada com toda a segurança, no que diz respeito às propriedades avaliadas neste trabalho. / Brazil, similar to other countries, is aging quickly. The individuals with more than 60 years old compose today the segment that more grows in proportional terms, showing an increment of about 500% in 40 years. The estimate for 2020 is that Brazil has around 32 million elderly and a significant parcel of them will be partial or totally toothless, needing prosthetic equipments. In spite of notable scientific advance in the rehabilitation of the oral health, many people still will use these equipments. The continuous use of the prosthesis can propitiate the development of denture stomatitis, whose etiology is multifactorial, being generally, associated to the presence of fungus Candida albicans. Bad oral hygiene and prosthesis is still distinguished as factor of risk. Therefore, it very necessary for the elderly a efficient, safe and easy handling method of disinfection with low occupational risk and that doesn’t intervene with the properties of the materials used in the confection of these prosthetic equipments. The aim of this work is to evaluate the influence of two disinfection methods on the properties of acrylic resin used in the confection of dental prosthesis. Samples had been confectioned in accordance with the requirements of each test for the control groups (without treatment), as for the treated (submitted to one of the disinfection process). The evaluated properties had been resistance and module of flexure, Izod impact, Knoop microhardness, rugosity, specific mass and degree of swelling, degree of conversion of monomer, glass transition temperature, sorption and solubility. The treatments of disinfection had consisted of: a) irradiation with energy of microwaves, in the power of 840 W, during 1 min, or b) immersion in peracetic acid during 5 min. The effectiveness of the disinfection was evaluated by means of microbiological tests, in which was verified the occurrence of growth of Candida albicans through of culture and sample surface. For that, the samples were previously contaminated with one type of fungus (known as ATCC 10231) and, after, submitted to one of the two considered processes of disinfection. The work was studied the behavior of three commercial acrylic resins of dental use: acrylic resins of thermal polymerization, self-polymerization and polymerization for energy of microwaves (type 1, 2 and 5 respectively) from two different suppliers The results had shown that the acrylic resins of type 1 and type 5 presented similar values in all the analyzed properties. The acrylic resins of type 2 had also similar values in all the properties, but statistically lower than ones of type 1 and 5. The best polymerization cycle, which did not modify the resin properties, was that one considered by the respective manufacturer of the acrylic resin. The nylon fiber presence and colouring did not influence the properties of the acrylic resin of type 5. The first irradiation with microwaves significantlyincreased the evaluated properties and the first immersion in peracetic acid did not modify these properties, in comparison to the control groups. After 20 months, the immersion in peracetic acid did not modify the properties of the material, while the microwave irradiation showed alterations in some properties. Both disinfection techniques had been efficient of the microbiological point of view. On the basis of these results, can be concluded that the microwave irradiation after the polymerization of the material (first cycle), can be recommended, since it increased all the values of the evaluated properties, specially to the conversion degree monomer/polymer. Nevertheless, for prolonged use, the disinfection by means of the immersion in peracetic acid must be recommended, it is efficient for elimination of fungal microorganism and security, characterized for the maintenance of the properties of the acrylic resin evaluated in this work.
|
873 |
Distribuição de tensões geradas por próteses esplintadas ou individualizadas sobre implantes com reabilitações em diferentes rebordos. Análise pelo método dos elementos finitos / Stress distribution generated by splinted or individualized implant prostheses with rehabilitation in different edges. A finite element analysisMarcelo Bighetti Toniollo 28 August 2014 (has links)
O emprego dos implantes ósseointegráveis na odontologia moderna tem conquistado destaque nas reabilitações de forma crescente. Em casos de perda óssea vertical severa, a qual se faz bastante presente em áreas posteriores mandibulares, o uso de implantes curtos e de diâmetro reduzido se faz necessário. Para que a reabilitação mantenha o plano oclusal nivelado, utiliza-se próteses sobre implantes com proporção coroa/implante aumentada, sendo importante avaliar se há sobrecarga das estruturas de suporte, e se convém a esplintagem da infraestrutura reabilitadora. Um dos métodos utilizados atualmente para análise de distribuição de tensões na odontologia é o método dos elementos finitos. Assim, este estudo teve o objetivo geral de comparar o desempenho biomecânico de próteses, esplintadas (PSIE) ou individualizadas (PSII), sobre implantes cone Morse de comprimento regular e curto, em área posterior de mandíbula. Foram usados modelos geométricos tridimensionais de implantes regulares ∅ 4x11 mm e curtos - ∅ 4x5 mm alojados em rebordos representativos do hemi-arco mandibular esquerdo posterior envolvendo o dente 34 adjacente ao espaço anodôntico, desenhados no programa SolidWorks 2007. Os 8 grupos experimentais foram: grupo controle E (3 implantes regulares reabilitados com PSIE), grupo 1E (2 implantes regulares e 1 curto reabilitados com PSIE), grupo 2E (1 implante regular e 2 curtos reabilitados com PSIE) e grupo 3E (3 implantes curtos reabilitados com PSIE); grupo controle I (3 implantes regulares reabilitados com PSII), grupo 1I (2 implantes regulares e 1 curto reabilitados com PSII), grupo 2I (1 implante regular e 2 curtos reabilitados com PSII) e grupo 3I (3 implantes curtos reabilitados com PSII); As alturas dos pilares usados foram 3,5 mm para implantes regulares e 0,8 mm para implantes curtos. Foram simuladas forças oblíquas (45° - linguo-vestibular) de 365N em molares e 200N em prémolares. Análises qualitativas e quantitativas da distribuição de tensões máximas e mínimas principais (ossos cortical e esponjoso) e tensão equivalente de von Mises (implantes, componentes e infraestruturas) foram feitas por meio do programa AnsysWorkbench10.0. Os resultados obtidos permitiram concluir que o uso de PSIE propiciou uma série de vantagens e benefícios com relação à distribuição de tensões nos elementos envolvidos no sistema, sendo benéfica a todos os grupos experimentais do presente estudo, notoriamente ao grupo com presença apenas de implantes curtos, diminuindo as tensões no osso circunjacente aos implantes, principalmente em sua abrangência. Também diminuiu as tensões na superfície dos implantes, na área de transmucoso dos pilares/componentes, na região interna das infraestruturas e sua abrangência ao osso circunjacente aos implantes curtos nos grupos com implantes regulares e curtos. No entanto, nesse mesmo contexto, gerou maior tensão ao osso circunjacente aos implantes regulares intermediários comparativamente aos grupos individualizados. Também favoreceu a diminuição das tensões ao osso circunjacente ao dente adjacente, quando na presença de proporção coroa/implante aumentada. O uso PSII apresentou-se vantajosa na diminuição das tensões na parte superior dos pilares e na área de conexão entre coroas, além do grupo controle, apenas com implantes regulares e próteses de proporção normal, sendo viável sua utilização neste contexto frente às vantagens clínicas não oferecidas pelas próteses esplintadas. / The use of dental implants in modern dentistry has gained prominence in oral rehabilitations. In cases of severe vertical bone loss, which is very much present in mandibular posterior areas, the use of short implants and reduced diameter is necessary. To maintain the occlusal plane level rehabilitation it is necessary the use of prostheses with increased crown/implant ratio , and it is important assess whether there is overhead of supporting structures, and befits splinting the rehabilitating infrastructure. One of the methods currently used to analyze the stress distribution in dentistry is the finite element method. Thus , this study has the overall objective to compare the biomechanical performance of prostheses, splinted (PSIE) or individualized (PSII) over Morse taper implants of regular and short length in the posterior area of the mandible. It were used three-dimensional geometric models of regular implants - ∅ 4x11 mm and short implants - ∅ 4x5 mm housed in representative edges of the posterior left mandibular hemi-arch tooth involving 34 teeth, designed in SolidWorks 2007 program. The 8 experimental groups were: control group E (3 regular implants rehabilitated with PSIE ), group 1E (2 regular and 1 short implants rehabilitated with PSIE) , 2E group (1 regular implant and 2 short implants rehabilitated with PSIE) and 3E group (3 short implants rehabilitated with PSIE); control group I (3 regular implants rehabilitated with PSII), group 1I (2 regular and 1 short implants rehabilitated with PSII), 2I group (1 regular implant and 2 short implants rehabilitated with PSII) and 3I Group (3 short implants rehabilitated with PSII); The pillars heights used for regular implants were of 3.5 mm and 0.8 mm for the short implants. Oblique forces (45° linguo-vestibular) were simulated in molars (365N) and premolars (200N). Qualitative and quantitative analysis of the distribution of maximum and minimum principal stresses (cortical and cancellous bone) and von Mises equivalent stress (implants, components and infrastructure) were made through the software AnsysWorkbench10.0. The results showed that the use of PSIE provided advantages and benefits regarding the stresses distribution in the elements involved in the system, being beneficial to all experimental groups of this study notoriously in the group with only short implants, reducing stresses in the surrounding bone to implants, especially in coverage. Also decreased the stresses on the implants surface, in the transmucosal abutments area, in the inner region of the infrastructure and its reach to the surrounding bone to short implants in groups with regular and short implants. However, in that respect, generated higher stresses to the surrounding bone of intermediate implants compared to the individualized groups. Also favoring a decrease of the stresses to surrounding bone adjacent to the tooth, in the presence of increased crown/implant ratio. The use PSII showed to be advantageous in reducing stresses on top of the abutments and the area of connection between crowns, and in the control group, only with regular implants and prostheses of normal crown/implant ratio, so it can be used in this context facing the clinical advantages not offered by splinted prostheses.
|
874 |
Estudo do desajuste angular e vertical em próteses fixas implantossuportadas por meio do MEF-3D /Gomes, Érica Alves. January 2009 (has links)
Resumo: Objetivo: A análise pelo método dos elementos finitos tridimensional foi utilizada para avaliar o efeito dos desajustes angular e vertical simulado em próteses fixas implantossuportadas parafusadas de 3 elementos, na resposta biomecânica do tecido ósseo peri-implantar, implantes e componentes protéticos. Material e método: Foram confeccionados 4 modelos tridimensionais, representativos de secção mandibular direita contendo um implante na região de segundo pré-molar (2oPM) e outro na região de segundo molar (2oM) ferulizados por uma prótese metalocerâmica implantossuportada parafusada de 3 elementos, diferenciados pelo tipo de desajuste protético, gerando os grupos: GC (grupo controle) - prótese totalmente adaptada aos implantes, DAU (desajuste angular unilateral) - prótese com desajuste angular unilateral de 100μm na região mesial do 2oM, DVU (desajuste vertical unilateral) - prótese com desajuste vertical unilateral de 100μm na região mesial do 2oM e DVT (desajuste vertical total) - prótese com desajuste vertical de 100μm em toda a plataforma de assentamento da infraestrutura no 2oM. Com a utilização do programa de elementos finitos Ansys® uma força vertical total de 400N foi distribuída em 12 pontos de parada cêntrica, sendo que cada molar recebeu um carregamento total de 150N e o 2oPM de 100N, gerando mapas de tensões. Resultados: Verificou-se que a distribuição e os valores de tensões para o tecido ósseo peri-implantar foram similares para todos os grupos. Os grupos com desajustes alteraram o padrão de distribuição e elevaram a magnitude das tensões em relação ao grupo GC. No grupo DAU os maiores valores de tensões foram observados no corpo do implante e parafuso de retenção. Já nos grupos DVU e DVT elevados valores de tensões foram encontrados na plataforma de assentamento da infraestrutura... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Purpose: The three-dimensional finite element analysis was used to evaluate the effect of vertical and angular misfit in 3-piece implant-supported and screw-retained fixed prostheses on biomechanical response in peri-implant bone tissue, implants and prosthetic components. Material and method: Four three-dimensional models were fabricated to represent a right posterior mandibular section with one implant in the region of second premolar (2°PM) and other in the region of second molar (2°M). The implants were splinted by a 3- piece implant-supported metal ceramic prosthesis and differed according to the type of misfit as represented by the groups: CG (control group) - prosthesis with complete fit to the implants, UAM (unilateral angular misfit) - prosthesis presenting unilateral angular misfit of 100μm in the mesial region of the 2°M, UVM (unilateral vertical misfit) - prosthesis presenting unilateral vertical misfit of 100μm in the mesial region of the 2°M, and TVM (total vertical misfit) - prosthesis presenting total vertical misfit of 100μm in the platform of the framework in the 2°M. A vertical load of 400N was distributed and applied on 12 centric points by the software Ansys®. So, vertical loading of 150N was applied on each molar while vertical load of 100N was applied on the 2°PM. Stress maps were obtained by processing of the finite element software. Results: The stress values and distribution on peri-implant bone tissue were similar for all groups. The groups presenting misfit exhibited different distribution pattern and increased stress magnitude in comparison to the group CG. The highest stress values in group UAM were observed in the implant body and retention screw. The groups UVM and TVM exhibited high stress values in the platform of the framework... (Complete abstract click electronic access below) / Orientador: Wirley Gonçalves Assunção / Coorientador: Edson Antônio Capello Sousa / Banca: Paulo Henrique dos Santos / Banca: Ricardo Faria Ribeiro / Banca: João Neudenir Arioli Filho / Doutor
|
875 |
Critérios para utilização de implantes protéticos com o apoio da Sociedade Brasileira de Quadril: um guia práticoGreiffo, Rosane Helena 11 September 2012 (has links)
A identificação de fatores relacionados à segurança e qualidade das próteses para artroplastia de quadril na visão do ortopedista especialista, bem como a busca e checagem por informações advindas dos instrumentos legais de regulação, tais como localização do Registro do Ministério da Saúde e rótulo de instruções de uso, com exata descrição das características dos dispositivos, a notificação e procura por alertas da Tecnovigilância podem apontar critérios que minimizem a possibilidade de erros e surgimento de eventos adversos na escolha dos implantes para quadril durante o processo de indicação, solicitação, liberação, implantação e utilização do produto. Investigando este contexto, foram entrevistados os membros da Sociedade Brasileira de Quadril, e do retorno das respostas surgiram dados que mostram que 72% dos sujeitos não acreditam que o Registro da ANVISA faça parte de um processo de segurança e qualidade no cadastramento de produtos para saúde no Brasil, e outros 72% desconhecem a ferramenta Tecnovigilância para monitoramento pós-comercialização. Todavia, 94% da amostra refere já ter constatado falha protética ao longo da carreira, outros 94% indicam que a falha ocorreu com próteses nacionais, e que em 60% das ocorrências o fornecedor foi contatado, e não a ANVISA, e em outros 30% das falhas nada foi feito. Estes dados são preocupantes, pois refletem o descompasso entre a Agência Nacional de Saúde e a classe de médicos assistentes no que tange ao monitoramente de tecnologias em saúde, estes por não notificarem os EA (evento adverso) e QT (queixa técnica) ao órgão regulatório, e a Agência que, por conseguinte, não divulga amplamente esta ferramenta a quem de fato deveria ser o alvo de atenção, pois são estes que utilizam, na prática diária, os produtos registrados no Brasil. Na tentativa de facilitar a conferência de dados imprescindíveis relacionados à OPME(órteses, próteses e materiais especiais) entre eles próteses para quadril, elaborou-se uma revista eletrônica intitulada Guia Prático para checagem de questões sobre segurança e qualidade de dispositivos médicos cirúrgicos de acordo com procedimentos da ANVISA. / Identification factors related to safety and quality of prostheses for total hip arthroplasty according to the orthopedic specialists, as well as the search and checking for information from the legal instruments of regulation such as the registry made by the Ministry of Health and corresponding label functioning instructions containing the exact description of the characteristics of the devices, alert notifications for technical surveillance, etc., can lead to criteria that minimize errors and avoid adverse events when choosing hip implants, during the process of request, release, deliver and use of the product. In order to investigate this context, a survey was made by means of a questionnaire where members of the Hip Brazilian Society answered selected questions. Data from answers have shown that 72% of respondents do not believe that the ANVISA (National Health Agency) product registration is part of a safety and quality process for health products in Brazil, and another 72% are unaware of the pos market monitoring tool called Tecnovigilância. However, 94% of the medical doctors state that they already have found prosthetic failure throughout their career, other 94% indicate that the failure occurred with national prostheses, and in 60% of these cases the supplier was contacted and not the ANVISA, and for other 30 % of failures nothing was done. The exposure of these data is worrying since it reflects the gap between ANVISA and the physicians in regard to monitoring health technologies. Also, the doctors do not notify adverse events to the regulatory Agency and the Agency therefore does not disseminate this tool to those who actually should be the focus of attention since they use the products in their daily practice. Finally, in order to facilitate data verification of health products, in special hip phrostheses, a practical electronic guide was developed where questions and doubts about safety and quality of medical devices can be checked according to the ANVISA procedures.
|
876 |
A produ??o das perdas dent?rias: narrativas de usu?rios do SUSDantas, Jussara de Azevedo 27 August 2008 (has links)
Made available in DSpace on 2014-12-17T15:30:52Z (GMT). No. of bitstreams: 1
JussaraAD.pdf: 601035 bytes, checksum: cffe252603743caec8889a83b0645aab (MD5)
Previous issue date: 2008-08-27 / For a complete comprehension of the effect of tooth loss is necessary to listen to the patients that have it. This study, of qualitative approach, investigate, in the dental history of users of SUS, listening to his/her experiences with the services of dental care, the reason that lead his/her to dental lost and the repercussion of this in his/her life. The collect of data was made by narrative interview, obeying to a pre-defined schema. The subjects interviewed were six (three of urban zone and three of rural zone), all of them were users of Family Health Units. The criterions of inclusion were the followings: the presence of tooth lost (total lost in both dental arch or in one of them, or partial lost in at least six elements in one of the arches); age between 25 and 59; male or female; to live in municipal district of S?o Tom?/RN or Natal/RN. Based on previous interviews was elaborated the odontological history of each patient. Such narratives, systemized in odontological history, were analyzed taking as base the
studies of Souza71 and the proposal of Schutze, suggested for Jovchelovitch, Bauer34. The results show that toothache was the main reason for the search of odontological care. The patients confront the ache with home-made medicaments, allopathic ones, and searching for dental care. The searching for exodontics was stimulated for geographic access difficulties or
for repressed demand, which as a result produced the aggravation of the lesions and the discredit in restoration s treatment. The self-care practice of tooth-brush with ju? or toothpaste and the controlled ingestion of sugar was not sufficient to avoid dental lost. Guilty sentiments were identified in relation with lack of care with teeth. The acceptance of dental lost as a natural factor is an important motivation in lack of pain and in the belief that it was a simple part of life in old age. Life with dental prosthesis makes clear the difference between which was natural and which was unnatural, and difficulties with the prosthesis appeared. The limitation of the prosthesis in its functional aspect can be compensated by esthetic restitution,
making possible smiling expression. Starting with this study and considering the high number of dental lost, mainly in low-rent population, which live with toothless limitations or bad-quality prosthesis which do not rehabilitate adequately, we suggested the realization of qualitative researches which include, also, another actors in heath care services such as
professionals and administrators / A compreens?o ampliada dos efeitos da perda dent?ria exige escuta dos sujeitos que a experimenta. Este estudo, de abordagem qualitativa, investigou, na hist?ria odontol?gica de usu?rios do SUS, a partir do relato de suas experi?ncias com os servi?os de sa?de bucal, os motivos que os levaram ? perda dent?ria e as repercuss?es desta em suas vidas. A coleta de
dados foi realizada por meio da t?cnica de entrevista narrativa, adaptada, utilizando-se roteiro semi-estruturado. Os sujeitos entrevistados, num total de seis (tr?s da zona urbana e tr?s da zona rural), foram usu?rios de Unidades de Sa?de da Fam?lia. Consideraram-se os seguintes crit?rios de inclus?o: presen?a de desdentamento (perda total em ambas as arcadas, ou em uma delas, ou perda parcial a partir de seis elementos em uma das arcadas); idade ente 25 e 59 anos; qualquer g?nero; ser morador dos munic?pios de S?o Tom?/RN e Natal/RN. A partir do conte?do das entrevistas foi elaborada a hist?ria odontol?gica de cada entrevistado. Tais narrativas, sistematizadas em hist?rias odontol?gicas, foram analisadas com base em estudo de Souza e na proposta de Sch?tze, sugerida por Jovchelovitch, Bauer. Os resultados indicaram que a experi?ncia de dor foi o principal motivo pela procura por assist?ncia odontol?gica. As formas de enfrentamento da dor deram-se pelo uso de medica??es caseiras e alop?ticas e pela busca do servi?o de sa?de. A procura pela exodontia foi favorecida pela
dificuldade de acesso geogr?fico ou pela grande demanda reprimida, o que produziu agravamento das les?es e descr?dito na efic?cia do tratamento restaurador. A pr?tica do autocuidado atrav?s da escova??o com ju? ou creme dental e o controle do consumo de a??car n?o foram suficientes para evitar a perda dent?ria. Foram identificados sentimentos de culpa
relacionados ? falta de cuidado. A aceita??o da perda dent?ria como natural teve forte rela??o com a garantia de aus?ncia de dor e a cren?a de fazer parte do processo de envelhecimento. A conviv?ncia das pessoas com a pr?tese dent?ria mostrou a diferen?a entre o que era natural e o que era artificial e, a partir da?, foram aparecendo situa??es de estranhamento com a
pr?tese. A limita??o da pr?tese quanto ao aspecto funcional pode ser compensada pela restitui??o da est?tica, ao possibilitar a express?o do sorriso. A partir deste estudo e considerando o elevado n?mero de perdas dent?rias, especialmente em popula??es de menor poder aquisitivo, que convivem com limita??es pr?prias da condi??o de desdentado e ou com pr?teses de m? qualidade que n?o reabilitam, adequadamente, sugere-se a realiza??o de pesquisas de abordagem qualitativa que inclua, tamb?m, outros atores implicados na produ??o de cuidados e servi?os de sa?de profissionais e gestores
|
877 |
Avalia??o da desadapta??o das selas de pr?teses parciais remov?veis ap?s 1 a 5 anos de usoAquino, Luana Maria Martins de 03 February 2009 (has links)
Made available in DSpace on 2014-12-17T15:30:52Z (GMT). No. of bitstreams: 1
LuanaMMA.pdf: 2018250 bytes, checksum: 40d3a2d59df5edbadcdae3ffaf599eb2 (MD5)
Previous issue date: 2009-02-03 / The non-adaptation of the removable partial prosthesis (RPP) base to fibromucosal tissue is caused by resorption of residual ridges (RRR). The onset of bone resorption, which occurs after tooth extraction and continues throughout life, is accelerated by
local or systemic factors. Aim: Assess the degree of non-adaptation of removable partial prosthesis saddles and the factors that influence it. Methodology: A sectional study was conducted with 81 patients using RPP who had their prostheses installed between 2003 and 2007 (1 to 5 years of use) at the Faculty of Dentistry of the Universidade Federal do Rio
Grande do Norte (UFRN). After anamnese and clinical examination, a cast was made with polyether-based material, using the base of the prosthesis to make the impression. The base of the saddle was loaded with the casting material and positioned in the mouth, applying pressure on the supports. After polymerization, the material was removed from the saddle and
measurements were taken at 3 different points using a pachymeter. Results: The non-adaptation of the saddle increased significantly with years of use (p = 0.005). The tooth-tissue supported prostheses obtained higher mean non-adaptation values than those of tooth supported prostheses (p < 0.001). Flaccid mucosa showed the worst non-adaptation results, which were statistically different from resilient mucosa (p < 0.001). The greater the extension
of the saddle, the greater the non-adaptation (p < 0.001). The natural tooth antagonistic arch yielded better results than did RPP and total prosthesis (p < 0.001). Saddle non-adaptation at the free end was less near the pillar tooth and greater in the more posterior region (p < 0.001). When adaptation of the supports to the niches was poor, greater saddle non-adaptation
occurred than when it was good or fair (p < 0.001). Saddles located in the posterior region of the arch had greater non-adaptation than those in the anterior region (p = 0.023). Conclusion: The mean non-adaptation of the saddle to the residual ridges was 0.27 mm. It can be concluded that, even with the use of RPP, bone height reduction was slight within the 1-5-year period of use. The following are factors that influence adaptation of the RPP saddle base: years of use, age, force transmission path to the alveolar bone, location of the toothless area, antagonistic arch, type of mucosa, adaptation of supports to the niche and extension of the saddle / A desadapta??o da base das pr?teses parciais remov?veis (PPR) com o tecido fibromucoso ? causada pela reabsor??o dos rebordos residuais (RRR). A reabsor??o ?ssea inicia logo ap?s a exodontia de um elemento dent?rio e continua por toda a vida, sendo
acelerada por fatores locais ou sist?micos. Objetivo: Avaliar o grau de desadapta??o das selas de pr?teses parciais remov?veis e os fatores que a influenciam. Metodologia: Foi realizado um estudo seccional com 81 pacientes usu?rios de PPR que instalaram suas pr?teses no per?odo de 2003 a 2007 (1 a 5 anos de uso) no Departamento de Odontologia da UFRN. Ap?s
a anamnese e do exame f?sico, foi realizada uma moldagem com material a base de poli?ter, utilizando a base da pr?tese como moldeira, para copiar o espa?o existente entre a base da sela e o rebordo residual. A base da sela foi carregada com o material de moldagem e levada em posi??o na boca, fazendo-se press?o sobre os apoios. Ap?s a polimeriza??o, removeu-se o
material de moldagem da sela e realizou-se a medi??o da espessura do molde com o aux?lio de um paqu?metro manual. Resultados: A desadapta??o da sela aumentou significativamente a medida que aumentavam os anos de uso (p=0,005). Indiv?duos com 50 anos ou mais,
apresentaram maior desadapta??o do que indiv?duos mais jovens (p<0,001). As pr?teses dentomucossuportadas obtiveram maiores m?dias de desadapta??o do que as dentossuportadas (p<0,001). O tipo de mucosa fl?cida apresentou piores resultados de adapta??o sendo estatisticamente diferente da mucosa resiliente (p<0,001). Quanto maior a extens?o da sela, maior a desadapta??o (p<0,001). O arco antagonista dente natural apresentou melhores resultados em rela??o a PPR e pr?tese total (p<0,001). A desadapta??o da sela em extremidade livre foi menor pr?ximo ao dente pilar e maior na regi?o mais posterior da sela (p<0,001). A adapta??o dos apoios aos nichos quando se encontrava ruim obteve maior desadapta??o da sela comparadas as adapta??es do tipo boa e regular (p<0,001). Selas localizadas em regi?o posterior do arco obtiveram maiores desadapta??o que as selas em regi?o anterior (p=0,023). Conclus?o: A m?dia de desadapta??o da sela sobre os rebordos residuais foi de 0,27mm, podendo-se concluir que, mesmo com o uso da PPR, a redu??o da altura ?ssea foi pequena dentro do per?odo de 1 a 5 anos de uso. S?o fatores que influenciam
na adapta??o da base da sela de PPR: tempo de uso da pr?tese, idade, via de transmiss?o de for?a para o osso alveolar, local da ?rea desdentada, arco antagonista, tipo de mucosa, adapta??o dos apoios nos nichos e extens?o da sela
|
878 |
Satisfa??o dos usu?rios e qualidade dos tratamentos prot?ticos realizados nos Centros de Especialidades Odontol?gicas da Grande Natal RNCosta, Anna Paula Serejo da 18 March 2011 (has links)
Made available in DSpace on 2014-12-17T15:30:56Z (GMT). No. of bitstreams: 1
AnnaPSC_DISSERT.pdf: 1055344 bytes, checksum: 3820065b4404d2eed0b9f94f68a004b1 (MD5)
Previous issue date: 2011-03-18 / Aim: To evaluate user satisfaction and quality of prosthetic treatments performed in specialized dental clinics (CEOs) of Natal Metropolitan Region - RN. Methods: Cross-sectional study with subjects who underwent prosthetic CEOs in the cities of Natal, Maca?ba, Parnamirim and Sao Goncalo do Amarante in the period 2007 to 2009. Data collection was performed by questionnaire, clinical examination of the oral cavity and examination of fabricated denture. This analysis involved the following aspects: retention, stability, aesthetics and prosthesis fixation. The variables are presented by means of absolute numbers and proportions. The determination of the association between the independent and dependent variables was conducted by the association of Chi-square test and Fisher exact test. Results: A total of 149 users, totaling 233 conventional dentures (148 upper and 85 lower). Most patients (56.4%) were rehabilitated with conventional complete dentures. The technical quality of the denture was regarded as satisfactory in the majority (52.7%), whereas the inferior dentures were rated as unsatisfactory in 90.5% of cases. Satisfaction with the prosthesis was 69.1% (N = 103). The average time to begin treatment was 3 months to receive while the prosthesis was 4 months old. The presence of injury from the upper prosthesis occurred in 21.5% of cases (N = 32), candidiasis being the most frequent (N = 18). The technical quality of the upper prosthesis (p=0,041), as well as retention (p=0,002) and stability (p<0,001) were significantly associated with user satisfaction. Conclusions: The specialized
Dental clinics has been fulfilling its role of providing treatment of intermediate complexity for low-income population with the majority of satisfield patients, even when their dentures have problems of technical quality / Objetivo: Avaliar a satisfa??o dos usu?rios e a qualidade dos tratamentos prot?ticos realizados nos Centros de Especialidades Odontol?gicas (CEOs) da Grande Natal-RN. M?todos: Estudo transversal com os indiv?duos que realizaram tratamento prot?tico nos CEOs dos munic?pios de Natal, Maca?ba, Parnamirim e S?o Gon?alo do Amarante no per?odo de 2007 a 2009. A coleta de dados foi realizada atrav?s de question?rio, do exame cl?nico da cavidade oral dos usu?rios e da pr?tese dent?ria confeccionada. Tal an?lise envolveu os seguintes aspectos: reten??o, estabilidade, fixa??o e est?tica das pr?teses. As vari?veis s?o apresentadas de maneira descritiva por meio de n?meros absolutos e propor??es. A determina??o da associa??o entre as vari?veis independentes e as vari?veis dependentes foi realizada pelo teste de associa??o qui-quadrado e o teste exato de Fisher. Resultados: Foram examinados 149 usu?rios, totalizando 233 pr?teses totais convencionais (148 superiores e 85 inferiores). A maioria dos pacientes (56,4%) foi reabilitada com pr?teses totais convencionais bimaxilares. A qualidade t?cnica das pr?teses totais superiores foi tida como satisfat?ria na sua maioria (52,7%), enquanto que as pr?teses inferiores foram classificadas como insatisfat?rias em 90,5% dos casos. A satisfa??o com as pr?teses foi de 69,1% (N=103). O tempo m?dio para come?ar o tratamento foi de 3 meses enquanto que para receber a pr?tese foi de 4 meses. A presen?a de les?o proveniente da pr?tese superior ocorreu em 21,5% dos casos (N=32), sendo a candid?ase a de maior ocorr?ncia (N=18). A qualidade t?cnica das pr?teses superiores (p=0,041), bem como a reten??o (p=0,002) e a estabilidade (p<0,001) apresentaram associa??o significativa com a satisfa??o do usu?rio. Conclus?es: Os Centros de Especialidades Odontol?gicas vem cumprindo o seu papel de fornecer tratamento de m?dia complexidade para a popula??o de baixa renda, estando a maioria dos pacientes satisfeitos, mesmo quando suas pr?teses apresentam problemas de qualidade t?cnica
|
879 |
Le larynx artificiel : de l'in vitro à la première implantation clinique / Laryngeal replacement after total laryngectomyDupret Bories, Agnès 30 September 2013 (has links)
Objectifs : Ce travail a pour but de développer un larynx artificiel composé de 2 structures : 1) une structure inamovible en titane poreux prolongeant la trachée; 2) une double valve remplissant la fonction de sphincter. Matériels et Méthodes : L’intégration de la prothèse en remplacement trachéal a été testée in vitro et in vivo sur les modèles animaux rats, lapins et brebis. Suite à l’ensemble de ces résultats, nous avons réalisé la première application clinique du larynx artificiel. Résultats : 1) L’ajout d’un tube de silicone endoprothétique améliore la survie chez le gros animal; 2) l’intégration tissulaire de la prothèse de trachée associée à un matériel polymérique biodégradable était supérieure à celle des prothèses en titane poreux nu; 3) la vitesse de colonisation des prothèses en titane poreux était accélérée lorsque l’on diminuait la taille des billes. Un premier patient a été implanté avec une prothèse de larynx artificiel avec des résultats satisfaisants à 9 mois. Conclusions : Nos études concernant l’intégration de prothèses de trachées in vitro et in vivo ont permis de contribuer à l’aboutissement de la première application clinique de larynx artificiel. / Background: The aim of this work is the design of an artificial larynx made of 2 elements: 1) a non-removable bio-integrable structure designed to provide a connection with the remaining trachea; 2) a double valve that fulfills the sphincter function. Materials and Methods: In vitro and in vivo tests (rat, rabbit and sheep model) were performed to achieve the tracheal prosthesis integration. Following all these results, we carried out the first clinical application of an artificial larynx. Results: i) The long-term survival of the animals was improved when an endoprosthetic silicon calibration tube was used; ii) tissue integration of the prostheses in porous titanium filled with biodegradable polymer was better than the bare porous titanium; iii) prosthesis integration was improved when pore size was decreased. A first patient was implanted with an artificial functional larynx with satisfactory results after 9 months of implantation. Conclusion: The whole in vivo and in vitro studies concerning the integration of the tracheal prosthesis has contributed to the success of the first clinical application of the artificial larynx.
|
880 |
Relação da distância interimplantar e altura do ponto de contato na formação de papilas gengivais: estudo em cães / Influence of interimplantar distance and height from the point of contact in the formation of gingival papilae: a study in dogsDiogo Rodrigues Cruvinel 24 April 2009 (has links)
Os implantes dentais são considerados uma modalidade de tratamento bastante previsível para a reposição de dentes perdidos. Os implantes osseointegráveis principalmente quando colocados em regiões anteriores devem oferecer, além de excelente função, ótima estética, e fonética. Sendo que o critério para o sucesso envolve o estabelecimento do contorno de tecido mole, apresentando a área interproximal intacta. O propósito deste estudo foi avaliar a influência das diferentes distâncias (3 e 5 mm) entre a crista óssea e ponto de contato interdental, na formação de papila gengival associado à presença de diferentes distâncias (2 e 3 mm) entre implantes contíguos e na região de extremo livre mesial e distal. Foram selecionados para o experimento 8 cães adultos jovens e executada a exodontia dos 4 pré-molares mandibulares: p1, p2, p3, p4, para cada hemi-mandibula. Três meses após as exodontias foram colocados 3 implantes Replace Select Tapered com superfície tratada e dimensões de 4,3 X 10 mm, em cada hemimandibula animal. O primeiro implante foi colocado a 10 mm da distal do canino remanescente, o segundo (intermediário) foi colocado a 2 mm do primeiro e o terceiro implante (posterior) foi colocado a 3 mm do segundo. Foi iniciada a reabilitação protética, no dia da colocação dos implantes. Primeiramente foi feita a moldagem para a confecção das próteses metálicas. As coroas metálicas definitivas, confeccionadas, apresentaram distância do ponto de contato à crista óssea de 3 e 5 mm lado esquerdo e direito respectivamente. Ao completar 12 semanas pós-colocação das próteses definitivas, os animais foram sedados e as análises clínicas foram executadas. Esta avaliação foi feita a partir da utilização de um compasso de pontas secas, medindo as distâncias entre os pontos de contato e as pontas das papilas (PC - P) e dos pontos de contato aos extremos livres mesial e distal (PC - ELM e PC ELD respectivamente). O delineamento das situações experimentais foi executado levando em consideração as associações das diferentes distâncias interimplantar com as diferentes distâncias do ponto de contanto a crista óssea, assim encontramos a seguinte disposição: Situação 01 (PC3A) Distância do ponto de contato a gengiva do extremo livre mesial, do lado esquerdo; Situação 02 (PC3B) Distância do ponto de contato, a gengiva interproximal sendo à distância interimplantar de 2 mm, lado esquerdo da mandíbula; Situação 03 (PC3C) Distância do ponto de contato, a gengiva interproximal sendo a distância interimplantar de 3 mm, lado esquerdo da mandíbula; Situação 04 (PC3D) Distância do ponto de contato a gengiva do extremo livre distal, do lado esquerdo Situação 05 (PC5A) Distância do ponto de contato a gengiva do extremo livre mesial, do lado direito; Situação 06 (PC5C) Distância do ponto de, a gengiva interproximal sendo a distância interimplantar de 3 mm, lado direito da mandíbula; Situação 07 (PC5B) Distância do ponto de contato, a gengiva interproximal sendo a distância interimplantar de 2 mm, lado direito da mandíbula e Situação 08 (PC5D) Distância do ponto de contato a gengiva do extremo livre distal, do lado direito. Ao analisar as medias das alturas gengivais temos: PC3A a média de 2,9±0,5 mm; PC3D 2,5±0,5 mm; PC3B 1,8±0,6 mm; PC3C 2,0±0,8 mm; PC5A 3,0±0,5 mm; PC5D 3,5±0,4 mm; PC5C 3,6±0,4 mm e PC5B 3,9±0,7 mm. Como as premissas de aderência à distribuição normal, independência entre os indivíduos estudados e pareamento entre as diferentes etapas foram cumpridas, empregou-se a análise de variância (ANOVA) para mensurações repetidas, a dois fatores. Nos casos em que a ANOVA encontrou diferença entre as situações testadas, uma comparação a posteriori foi executada por meio do teste de Bonferroni. O nível de significância empregado para todos os testes foi de 0,05 (5%). Logo as distâncias de 2,0 e 3,0 mm entre implantes contíguos não apresentaram diferença significativa na formação de papila quando as restaurações protéticas são confeccionadas com 3 ou 5 mm de distância entre o ponto de contato e a crista óssea. Considerando a provável reabsorção óssea em ambos os grupos, quando a distância do ponto de contato à crista óssea foi inicialmente de 3 mm esta condição apresentou melhores resultados na formação de papilas do que a distância de 5 mm em todas as situações estudadas. A presença do ponto de contato de 3 mm influência positivamente na formação de papila, quando comparada com as regiões de extremo livre. / The dental implants are considered a form of treatment rather predictable for replacement of lost teeth Implants should offer, as well as excellent function, aesthetics and phonetics great, especially when placed in anterior regions, where the criterion for success involves the establishment contour of the soft tissue, showing the area intact interproximal The purpose of this study was to evaluate the influence of different distances between the bone crest and interdentally contact point, with 3 and 5 mm, the formation of gingival papilla associated with the presence of different distances of 2 and 3 mm between implants and the adjacent region of mesial and distal end free. Were selected for the experiment 08 dogs and young adults performed the extraction of the 4 pre molars mandibles: p1, p2, p3, p4, for each hemi-mandible. Three months after the tooth extractions were placed 3 Replace Select Tapered implants with treated surface and dimensions of 4.3 X 10 mm in each animal hemi mandibles. The first implant was placed at 10 mm distal of the canine left, the second (middle) was placed at 2 mm from the first and third implant (back) was placed at 3 mm from the second. Prosthetics rehabilitation has begun on the day of the placement of implants. First was the casting for the manufacture of metal stents, since the provisional prostheses were made of acrylic resin so that the distance between the point of contact and the bone crest is 3 mm on the left side of the mandible and 5 mm on the right. The final metal crowns, made, made from the point of contact to bone crest of 3 and 5 mm. After completing 12 weeks after placement of final prosthesis, the animals were sedated and the clinical tests were performed. This evaluation was made from the use of a dry bar for tips, measuring the distances between the points of contact and the tips of the papillae (PC - P) and the contact points of the mesial and distal ends free (PC - PC and ELM - ELD respectively). The design of the experimental situations was implemented taking into account the associations of different distances interimplantar with different distances from the long bone crest, we found the following provision: Location - 01 (PC3A) Distance from the point of contact to end the free gingiva mesial to the left; Situation - 02 (PC3B) Distance from the point of contact, the gingival interproximal distance being interimplantar of 2 mm, the left side of the mandible; Situation - 03 (PC3C) Distance from the point of contact, the gingival interproximal and interimplantar a distance of 3 mm, the left side of the mandible; Situation - 04 (PC3D) Distance from the point of contact to the extreme free gingival distal to the left position - 05 (PC5A) Distance from the point of contact to the extreme free gingival mesial on the right side; Situation - 06 (PC5C) distance from the interproximal gingival interimplantar the distance of 3 mm, right side of the jaw; Situation - 07 (PC5B) Distance from the point of contact, the gingival interproximal the distance interimplantar of 2 mm, the right side of the mandible and Situation - 08 (PC5D) Distance from the point of contact to free distal end of the gingival on the right side. In examining the measures of gingival heights are: PC3A an average of 2.9 ± 0.5 mm; PC3D 2.5 ± 0.5 mm; PC3B 1.8 ± 0.6 mm; PC3C 2.0 ± 0.8 mm; PC5A 3.0 ± 0.5 mm; PC5D 3.5 ± 0.4 mm; PC5C 3.6 ± 0.4 mm and PC5B 3.9 ± 0.7 mm. As adherence to the assumptions of normal distribution, independence among the subjects studied and matching between the different stages have been completed, using the analysis of variance (ANOVA) for repeated measurements, the two factors. Where ANOVA found the difference between the conditions tested, a posteriori comparison was performed using the Bonferroni test. The significance level used for all tests was 0.05 (5%). Once the distances of 2.0 and 3.0 mm between adjacent implants showed no significant difference in the formation of the papilla when prosthetic restorations are made with 3 or 5 mm distance between the point of contact and the bone crest. Considering the probable bone resorption in both groups, where the distance from the point of contact to the bone crest was originally the condition of 3 mm showed better results in the formation of papillae than the distance of 5 mm in all cases studied. The presence of the point of contact 3-mm positively influence the formation of papilla, when compared with regions of extreme freedom.
|