• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 393
  • 140
  • 74
  • 72
  • 4
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 686
  • 277
  • 276
  • 276
  • 276
  • 212
  • 191
  • 190
  • 62
  • 50
  • 49
  • 48
  • 47
  • 47
  • 47
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
501

Comparação entre a tomografia computadorizada multislice e a tomografia computadorizada por feixe cônico para identificação de lesões osteolíticas simuladas na cabeça da mandíbula / Comparison between multislice computed tomography and cone beam computed tomography for assessment of simulated mandibular condyle lesions

Alexandre Perez Marques 04 February 2010 (has links)
A articulação temporomandibular (ATM) apresenta diversas limitações quando se obtém imagens pela radiologia convencional. A tomografia computadorizada é o exame mais indicado, pela alta especificidade e sensibilidade, para o diagnóstico, planejamento cirúrgico e tratamento das suas lesões ósseas. O objetivo deste trabalho consiste na comparação entre a tomografia computadorizada (TC) multislice e a tomografia computadorizada por feixe cônico (TCFC) para avaliação de lesões ósseas simuladas na cabeça da mandíbula. Foram utilizadas 30 cabeças de mandíbulas maceradas onde foram criadas lesões esféricas, com o auxílio de brocas cirúrgicas esféricas de uso odontológico com tamanhos variados (nº 1, 3, 6), em suas cinco porções (anterior, lateral, posterior, medial, superior). As lesões foram submetidas a TC multislice (64 canais) e a TCFC, sendo avaliadas em dois programas de pós-processamento por dois observadores independentemente, sendo um deles em duas ocasiões distintas. Foram utilizados também dois protocolos de análise para exame das imagens quanto à presença ou não de perfuração: reconstrução multiplanar (axial, coronal, sagital) e cortes sagitais e coronais ao longo eixo da cabeça mandibular. Posteriormente, os resultados brutos foram comparados com as lesões presentes na mandíbula macerada (Padrão-Ouro) avaliando a proporção de acertos de cada observador, o grau de especificidade e sensibilidade dos diferentes métodos da TC e da TCFC, e a comparação intra-observador e inter-observadores. O teste z foi utilizado como método estatístico. Os resultados demonstraram não haver diferenças estatisticamente significantes entre os métodos em relação às porcentagens de concordância e que todos estes são validados. Os protocolos para visibilização da região de cabeça da mandíbula foram estabelecidos no intuito de melhorar a identificação da presença de alterações de cada porção da cabeça da mandíbula. Houve maior dificuldade na avaliação de lesões simuladas de pequena dimensão (broca 1) / There are many limitations for image acquisition using conventional radiography of the temporomandibular joint (TMJ) region. Computerized tomography (CT) scan is a better option due to its higher specificity and sensitivity for diagnosis, surgical planning and treatment of bone injuries. The purpose of this study is to compare multislice CT and cone beam computed tomography for evaluation of simulated mandibular condyle lesions. Spherical lesions were created in 30 dry mandibular condiyle with dentist drills (sizes 1, 3, and 6). Condyles were submitted by multislice (64 bits) CT and cone beam computed tomography (CBCT) using two independent software by 2 observants alone, one of them in 2 different occasions, using 2 protocols: axial, coronal and sagittal, and sagittal plus coronal slices for the mandibular condyle visualization. The raw data were compared with the dry mandible (gold standard) regarding the presence of injuries, evaluating the proportion of agreement, degree of specificity and sensitivity of the CT and CBCT and observant analysis. The z test were used as statistical methods. The results showed there are no statistically significant differences between the methods, and the whole methods are validity. It was observed the advantage of the association of axial, coronal and sagittal slices and sagittal plus coronal slices for detection of lesions in mandibular condyles. For some lesions localized in regions, protocols did not show statistically significant differences regarding the proportion of agreement. Protocols were created to improve the visualization of lesions in each region of the mandibular condyle. There was more difficult for assessment small size simulated lesions (# 1).
502

Estudo do retalho nasosseptal para reconstrução endoscópica da base do crânio anterior / Study of the nasosseptal flap for endoscopic skull base reconstruction of the anterior cranial base

Carlos Diógenes Pinheiro Neto 31 August 2011 (has links)
Introdução: O uso do retalho nasosseptal (NS) para a reconstrução endoscópica da base do crânio foi fator fundamental para o avanço dos acessos endonasais expandidos. Objetivos: Aferir as dimensões do retalho NS e do defeito da base do crânio anterior (BCA) após ressecção craniofacial endoscópica e verificar a suficiência do retalho para cobrir o defeito. Estudar a anatomia da artéria septal (AS) e sua relação com o óstio do seio esfenoide. Métodos: Estudo anatômico do retalho NS em 14 cadáveres. Após ressecção craniofacial endoscópica, foi verificado a suficiência do retalho em cobrir o defeito na BCA. A AS foi dissecada e estuda quanto ao número de ramos presentes no pedículo e sua distância em relação ao óstio do seio esfenoide. Estudo radiológico com tomografia computadorizada de 30 pacientes para a comparação entre medidas do retalho NS e as do defeito na BCA. Resultados: O retalho foi suficiente para cobrir o defeito na BCA nas 14 dissecções. Em 71,4% dos casos, dois ramos da AS foram encontrados no pedículo. A distância média entre o primeiro ou único ramo ao óstio do esfenoide foi de 9,3mm. No estudo radiológico, a média da área reconstrutora do retalho (17,12cm2) foi constantemente maior que a média da área do defeito (8,64cm2) (p<0,001). A diferença entre o comprimento superior do retalho e a distância anteroposterior do defeito foi menor ou igual a 5mm em 26,7% dos casos. A comparação entre a largura anterior do retalho e a distância interorbitária anterior revelou que em 33% dos casos a diferença foi 5mm. A incorporação da mucosa do assoalho da fossa nasal ao retalho aumentou essa diferença em mais 10mm em todos os casos. Conclusões: As dimensões do retalho NS são suficientes para cobrir o defeito na BCA. A extremidade anterior do comprimento anteroposterior do defeito apresenta maior risco de falha de cobertura. A incorporação da mucosa do assoalho da fossa nasal ao retalho é importante para diminuir o risco de falha de cobertura anterior na largura do defeito. Em geral, é mais comum a presença de dois ramos da AS no pedículo / Introduction: Use of the nasoseptal (NS) flap for endoscopic skull base reconstruction was an essential contribution for the evolution of the expanded endonasal approaches. Objectives: Measure the dimensions of the NS flap and the anterior skull base (ASB) defect after endoscopic craniofacial resection and verify if the flap is sufficient to cover the defect. Study the anatomy of the septal artery (SA) and its relation with the sphenoid ostium. Methods: Anatomical study of the NS flap in 14 cadavers. After endoscopic craniofacial resection, the sufficiency of the flap to cover the ASB defect was assessed. The SA was dissected and studied regarding the number of branches in the pedicle and the distance between the artery and the sphenoid ostium. Radiological study using CT scans of 30 patients for comparison among measurements of the NS flap and the ASB defect. Results: The flap was sufficient to cover the ASB in all 14 dissections. In 71.4% of the cases, 2 branches of the SA were found in the pedicle. The distance between the first or the only single branch of the SA to the sphenoid ostium was 9.3mm. In the radiological study, the reconstruction area of the flap (17.12cm2) was constantly larger than the defect area (8.64cm2) (p<0.001). The difference between the superior length of the flap and the anterior-posterior distance of the defect was 5mm in 26.7% of the cases. Comparison between the flap anterior width and the defect anterior width revealed that in 33% the difference was 5mm. The incorporation of the nasal floor mucosa to the flap increased that difference in more than 10mm in all cases. Conclusions: The dimensions of the NS flap are sufficient to cover completely the ASB defect. The anterior edge of the anterior-posterior length of the defect presents increased risk for failure in coverage. The additional width provided by the incorporation of the nasal floor mucosa to the flap is important to decrease the risk of failure in coverage of the anterior defect width. In general, it is more common to find 2 branches of the SA in the pedicle
503

Dosimetria em tomografia computadorizada de feixe cônico odontológica / Dental Cone Beam Computed Tomography Dosimetry

Rodrigo Antonio Pereira Mauro 13 June 2017 (has links)
Os objetivos deste trabalho foram caracterizar os níveis de referência de radiodiagnóstico para a tomografia computadorizada de feixe cônico odontológica e as características de desempenho dos equipamentos como quilovoltaqgem de pico, rendimento, camada semirredutora, etc., com o intuito de conhecer os níveis dosimétricos em que os pacientes estão expostos, permitindo assim identificar protocolos de aquisição de imagem mais adequados, levando-se em consideração os princípios de radioproteção, e também testar a capacidade de tais equipamentos em alcançar uma imagem de qualidade. A Cone Beam Computed Tomography tem se tornado ferramenta extremamente útil na utilização em procedimentos radiológicos na área odontológica, pois, a riqueza de informações que a imagem 3D trás para o planejamento cirúrgico ou em qualquer procedimento, minimiza as possibilidades de erros, possibilita diagnósticos mais confiáveis e claros, tendo influência direta no resultado final esperado pelo paciente. Por se tratar de uma técnica de imagem que utiliza radiação ionizante, deve-se ter uma atenção criteriosa voltada para os níveis de radiação, além de implementar uma rotina de controle de qualidade. O parâmetro dosimétrico mais utilizado em tomografia computadorizada é o Computed Tomography Dose Index, porém, quando aplicado à tomografia odontológica, a geometria cônica do feixe e ainda a extensão do campo de visão tornam essa grandeza inviável e enganosa, assim, faz-se necessária a padronização de uma grandeza dosimétrica mais otimizada, para evitar a subestimação dos níveis de dose em feixes de ampla abrangência. O PKA tem sido utilizado como uma possível grandeza dosimétrica em tomografia odontológica, uma vez que em sua metodologia de medida, todo o feixe é englobado pelo medidor, não depende da distância fonte - detector, além de ser sensível aos parâmetros de exposição. Diante disso, propõe-se o PKA ser utilizado para estabelecimento dos níveis de dose de referência em diagnóstico odontológico. Os valores PKA obtidos para este estudo estão em uma faixa entre 34,6 mGy.cm^2 e 2901,6 mGy.cm^2, com valor médio de 980,7 mGy.cm^2. Os valores encontrados para os níveis de referência de radiodiagnóstico calculados a partir do 3º quartil estão divididos em três classes referentes ao tamanho do campo de visão, onde para campos pequenos, médios e grandes os valores são 1241 mGy.cm^2, 1521 mGy.cm^2 e 1408 mGy.cm^2 respectivamente, e 1446 mGy.cm^2 é o valor global independente do campo de visão. Os testes de controle de qualidade foram todos positivos, com uma atenção para o i-CAT FLX, que excedeu levemente o limite aceitável para a exatidão do kVp. Uma comparação entre CTDI100 e CTDI300, reportou que o CTDI300 é em média 49% maior em relação ao CTI100. Os níveis de referência de radiodiagnóstico são representativos dos níveis de dose otimizados, e servem como base para adequação e otimização dos parâmetros de exposição do equipamento. Os testes de controle de qualidade alertam para possíveis irregularidades no funcionamento do tomógrafo, e deve complementar obrigatoriamente a rotina dos procedimentos clínicos. / The objectives of this study are to characterize the radiodiagnostic reference levels for computed tomography of dental cones and as performance characteristics of equipment such as peak kyvoltage, yield, semi-reducing layer, etc., in order to know the levels of the values in that users are exposed, thus allowing to identify more adequate image acquisition protocols, taking in basic concepts of radioprotection, and also to test the capacity of such equipment in a quality image. The Cone Beam CT scan has become active, useful in medical, medical, dental, on the Internet, in any situation, minimizes as possibilities of errors, allows for more reliable and clear diagnoses, having a direct influence on the final result expected by the patient. Because it is an imaging technique that uses ionizing radiation, careful attention should be given to radiation levels, in addition to implementing a quality control routine. The dosimetric parameter most commonly used in computed tomography is the Computed tomography dose index, however, when applied to dental tomography, the conic geometry of the beam and still the extension of the field of view make this greatness unfeasible and deceptive, so it is done The. standardization of a more optimized dosimetric quantity, to avoid an underestimation of the dose levels in beams of wide range. The PKA has been used as a possible dosimetric magnitude in dental tomography, since in its measurement methodology, the whole beam is encompassed by the meter, it does not depend on the source - detector distance, besides being sensitive to the exposure parameters. Therefore, it is proposed that PKA be used for the establishment of reference dose levels in dental diagnosis. The PKA values obtained for this study ranged from 34.6 mGy.cm^2 to 2901.6 mGy.cm^2, with a mean value of 980.7 mGy.cm^2. The values found for the levels of radiodiagnostic reference values calculated from the 3rd quartile are divided into three classes referring to the size of the field of vision, where for small, medium and large fields are the values are 1241 mGy.cm^2, 1521 mGy.cm^2 and 1408 mGy.cm^2 respectively, and 1446 mGy.cm^2 is the global independent value of the field of view. The quality control tests were all positive, with an attention to the i-CAT FLX, which slightly exceeded the acceptable limit for kVp accuracy. A face between CTDI100 and CTDI300, reported that the CTDI300 is on average 49% higher than the CTI100. Radiodiagnostic reference levels are representative of optimized dose levels and serve as a basis for adequacy and optimization of the exposure parameters of the equipment. The quality control tests alert to possible irregularities in the operation of the tomograph, and develop properly from the clinical process.
504

Espectroscopia de raios X utilizando o espalhamento Compton / X-ray spectroscopy using compton scattering

Arlene Linke 16 September 2008 (has links)
O estudo do espectro de raios X é importante para predizer a qualidade da imagem em sistemas radiográficos. Nesse trabalho usamos um detector semicondutor CdTe para medir os espectros de raios X na faixa de 25 a 120 kVp. Esse detector é pequeno e fácil de ser transportado. As medidas feitas diretamente do tubo de raios X não são aconselháveis devido à alta taxa de fluência que estão acima dos limites de detecção dos detectores usuais e podem causar armadilhamento de carga no detector CdTe. A alternativa é medir os fótons espalhados a 900 a partir de um pequeno objeto espalhador, no nosso caso um cilindro de lucite (PMMA). A partir do espectro espalhado, corrigido para tempo morto e eficiência, e calibrado em energia, efetuamos correções para o ângulo de espalhamento e espalhamento coerente (somente para baixas energias). Só então formalismo de Klein-Nishina para as seções de choque do efeito Compton é aplicado aos espectros, resultando nos espectros primários. Para energia de 120 kVp foi medido um espectro do feixe direto e comparado com o obtido através do espectro espalhado para mesma energia. Para o mesmo feixe, a camada semi-redutora foi avaliada experimentalmente e com o espectro obtido por espalhamento Compton, obtendo-se boa concordância. Observamos na curva de eficiência uma descontinuidade, prevista teoricamente e também observada por outros autores, que deforma o espectro corrigido. Foi aplicado um ajuste polinomial a essa curva, suavizando os espectros obtidos e não alterando sua forma. Os resultados foram satisfatórios e validaram o formalismo apresentado por outros autores, utilizando detectores distintos. / The analysis of x-ray spectra is important to predict image quality in radiographic systems. In this work we used a semiconductor CdTe detector to measure x-ray spectra with a CdTe detector, in the range from 25 to 120 kVp. The CdTe detector is small and portable. The measurements done directly in the primary X rays beam can be difficult because of the high photon fluence rates that cause significant detector photon pile up, and can cause charge trapping in the CdTe. The alternative is to measure the photons scattered at 900 by a small scattering object, in our case a Lucite cylinder (PMMA). Starting from the scattered spectrum, corrected to dead time and efficiency and calibrated in energy, we made corrections for the scattering angle and coherent scattering (only at low energies). After that, the Klein Nishina cross section for Compton scattering are applied to the spectra, resulting in the primary spectra. For the 120 kVp beam a spectrum of the direct beam was measured and compared to the one obtained it through the scattered spectrum for the same energy. The half value layer of the same spectrum was determined experimentally and through the calculated spectrum, and the agreement was very good. The efficiency curve presents a discontinuity, also observed by other authors and predicted theoretically, that deforms the corrected spectrum. A polynomial fitting was adjusted to the efficiency curve, smoothing the corrected spectra without and not altering its form. The results were satisfactory and they validated the methodology presented by other authors, using different detectors.
505

Análise da imagem radiográfica de raízes apicetomizadas e irradiadas com laser de Nd:YAG por meio do processamento de imagem de radiografias digitais diretas / Radiographic image analysis of apicetomized roots irradiated with Nd:YAG laser using imaging processing of direct digital radiographs

Henrique Cesar Purchio Brucoli 22 September 2009 (has links)
Nesta pesquisa foi realizada a análise da imagem radiográfica digital da técnica periapical de raízes cujos ápices foram irradiados com laser de Neodymium Yttrium Aluminum Garnet (Nd:YAG) após a ressecção apical. Com intuito de encontrar alterações da imagem radiográfica digital das raízes causadas pela irradiação laser, desenvolvemos um modelo experimental in vitro. Foram realizadas as apicectomias de 39 raízes de dentes unirradiculares a dois milímetros do limite apical, com posterior fixação dos dentes em dispositivo que conferiu uma rígida padronização das radiografias, cujas imagens foram capturadas por meio de um sistema de radiografia digital direta (Dixi® Planmeca). Com a fixação das raízes no dispositivo de padronização, realizamos uma radiografia inicial, irradiamos os ápices radiculares com o laser de Nd:YAG e em seguida fizemos uma radiografia final, sem manipulação do sistema de padronização durante todo o processo. Os parâmetros de irradiação laser utilizados foram baseados no protocolo de pesquisa clínica para cirurgias apicais desenvolvido no Laboratório Especial de Laser em Odontologia (LELO-FOUSP). Foram eles 100mJ, 15Hz, 1,5W e diâmetro da fibra óptica de 320m. As radiografias foram obtidas com três tempos de exposição diferentes (0,05s, 0,08s e 0,14s). As imagens radiográficas antes e depois a irradiação laser, obtidas em 12 bits, foram convertidas para 8 bits e exportadas para o programa de análise de imagens ImageTool 3.0.0. A análise das imagens digitais foi executada por meio de histogramas e subtração de imagem digital quantitativa. Foi possível detectar por meio dos dois métodos uma menor quantidade de dentina na superfície apical após a irradiação com o laser de Nd:YAG. A variável tempo de exposição não apresentou diferenças estatísticas significantes, porém foi observada uma tendência de melhor desempenho dos métodos com imagens obtidas com exposição de 0,05s. Apesar de termos observado remoção de tecido dentinário, não foi possível detectar a presença de uma camada de dentina mais radiopaca nas imagens radiográficas da superfície irradiada. / In this research, we carried out an evaluation of the digital radiographic image of dental root-ends irradiated with Neodymium Yttrium Aluminum Garnet (Nd:YAG) laser after apical resection. With the intention of founding alterations in the digital radiographic image of the roots caused by laser irradiation, we developed an in vitro experimental model. We made apicectomy in 39 single-root teeth, 2 milimeters below the apical limit and then we fixed these teeth in a standardization device. The radiographic images were captured thru a direct digital radiographic system (Dixi® Planmeca). After positioning of the teeth in the standardization device, we made an initial radiograph, Nd:YAG laser irradiation of the apex and a final radiograph, without manipulation of the standardized system during the whole process. The laser parameters applied in this research followed the clinical research protocol for apical surgeries developed in the LELO- FOUSP. They were 100mJ, 15Hz, 1,5W and a 320m diameter optic fiber. The radiographs were made within three different exposure times (0,05s, 0,08s and 0,14s). The obtained 12 bit radiographic images before and after laser irradiation were converted to 8 bit images and exported to the ImageTool 3.0.0 image analysis software. With this software wee analyzed the digital images in the methods of histogram analysis and quantitative digital image subtraction. The two methods indicated less amount of dentin in the apical surface after Nd:YAG laser irradiation. The variable exposure time did not present statistical differences. However, we observed a tendency of better performance of the methods with images obtained with 0,05s exposure time. Although we observed dental tissue ablation, it was not possible to detect the presence of a more radiopac dentin layer in the irradiated surface radiographic images.
506

Estudo longitudinal da densidade mineral óssea de cães normais, portadores e afetados pela distrofia muscular do Golden Retriever (D.M.G.R.) / Longitudinal study of bone mineral density in healthy, carrier, and affected dogs by Golden Retriver Muscular Dystrophy (G.R.M.D.)

Robson Fortes Giglio 24 September 2004 (has links)
A forma mais comum de distrofia muscular em humanos é do tipo Duchenne, com uma incidência aproximada de um caso a cada 3.500 nascimentos masculinos. A Distrofia Muscular do Golden Retriever (DMGR) é considerada o modelo animal mais apropriado à Distrofia Muscular de Duchenne (DMD). A Densitometria Óptica Radiográfica é um método de análise para quantificação da matéria mineral óssea, sendo, neste estudo, realizado com radiografias simples da tíbia direita ao lado de escala de alumínio. Foram utilizados 15 cães da raça Golden Retriever, sendo 5 cães normais, 5 fêmeas portadoras e 5 machos afetados pela DMGR, que foram radiografados mensalmente, dos 3 aos 9 meses de idade. Estas radiografias foram digitalizadas e analisadas por meio de um software de análise de imagens (ImageLab, Softium®), que compara as tonalidades de cinza da escala com região óssea analisada, obtendo-se valores em milímetros de alumínio (mmAl). Os resultados obtidos foram analisados estatisticamente utilizando o procedimento Proc Means do programa Statistical Analysis System, versão 8.0. O estudo revelou que a região epifisária possui maior densidade mineral óssea (DMO), seguida pela região metafisária e diafisária, respectivamente, nos três grupos avaliados, ao longo do período experimental, e seguiram o comportamento do peso corpóreo. Houve uma tendência de aumento da DMO nas três regiões avaliadas dos três grupos ao longo do experimento. A região metafisária proximal de tíbia demonstrou ser a região de eleição para a leitura da DMO por ser o local estudado com menor correlação com o peso corpóreo e por promover estimativas médias consideradas significativas entre grupos avaliados mais cedo que nas demais regiões O potencial de diagnóstico do exame densitométrico, em relação a DMGR, foi considerado baixo, entretanto demonstrou ter grande potencial no acompanhamento do progresso desta doença por apresentar alta sensibilidade para detecção de variações na densidade mineral óssea. / Duchenne Muscular Dystrophy is the most common type of muscular dystrophy in humans affecting 1 in 3,500 male births. Muscular dystrophy in Golden Retrievers appears to be an appropiate model of the human Duchenne Muscular Dystrophy. Radiographic Optical Densitometry is an analitic method to meansure bone mineral content. This technique was performed by right tíbia simple radiograph conjugated with an aluminium stepwedge. 5 helthy dogs, 5 female carriers and 5 male affected dogs by Golden Retriever Muscular Dystrophy were divided in 3 groups. Monthly, all the dogs were radiographed from 3-mouths until 9-mouths old. Radiographs were digitalized and analyzed by an image processing software (ImageLab, Softium), which compares the aluminium grey scale tonalities with a bone region analyzed obtaining with this the value of bone mineral density in aluminium milimeters (mmAl). The obtained results were statistically analyzed using the the procedure Proc Means of the program Statistical Analysis System 8.0 software. The epifisary region possess higher bone mineral density followed for the metafisary and diafisary regions, respectively, in the three evaluated groups during the experimental period and followed by the behavior of the corporeal weight. There was a trend of increase of the bone mineral density in the three evaluated regions of all three groups. The proximal metafisary region of tíbia demonstrated to be the best region of selection to evaluate the bone mineral density since it is place studied with less correlation with the corporeal weight and by promoting significant considered average estimates between groups evaluated earlier than other regions. The potential of diagnosis of this densitometric method in Golden Retriever Muscular Dystrophy was considered low, however this study demonstrated to have great potential in the accompanying the progress of this disease due to the high sensitivity for detection of bone mineral density changes.
507

Radiologia convencional e tomografia computadorizada na avaliação de cães portadores de discopatia torácica, toracolombar, lombar ou lombosacra: estudo comparativo / Radiographic and tomographic exams in the evaluation of dogs with disease in thoracic, thoracolumbar, lumbar or lumbosacral spine: a comparative study

Iara Levino dos Santos 01 September 2006 (has links)
Foram avaliados 58 cães portadores de discopatia nos segmentos torácico, toracolombar, lombar ou lombosacro da coluna vertebral pelos exames radiográficos simples, contrastado (mielografia) e pela tomografia computadorizada (TC). Os animais com padrão de raça definido foram os mais acometidos (88%), sendo a raça Dachshund com maior representatividade (48%). A faixa etária mais acometida foi entre 4-7 anos de idade (48%). O exame radiográfico simples detectou aspectos radiográficos compatíveis com extrusão em 29 observações. A mielografia diagnosticou 98 protrusões, 43 extrusões e 10 hérnias de disco, além de fornecer informações relativas ao grau de comprometimento medular. A TC diagnosticou 84 observações de protrusões, 48 extrusões e 2 hérnias de disco. Os espaços mais comprometidos pela extrusão diagnosticados pelos métodos empregados foram T12-13, T13-L1 e T11-12. A TC esclareceu as dúvidas sugeridas pela mielografia, embora também apresentou limitações quando a compressão medular não apresentou a presença de material hiperatenuante. Nos casos com interrupção da coluna de contraste a TC foi capaz de detectar a extrusão devido à presença de material hiperatenuante em canal medular. Os métodos de diagnóstico por imagem empregados foram complementares e forneceram informações importantes para o prognóstico desses animais. / Disc disease in thoracic, thoracolumbar, lumbar or lumbosacral spine hás been evaluated in 58 dogs by survey radiography, mielography and computed tomography. The disc disease infrequently occurs in mixed-breed dogs; Dachshunds werw at higher risk for disc disease than other breeds (48%. Most dogs are between 4-7 years of age (48%). The survey radiography showed 29 observations of extrusions. The mielography showed 98 protrusions, 43 extrusions and 10 disc herniated. The CT showed 84 protrusions, 48 extrusions and 2 disc herniated. The affected disc spaces by extrusion seen in this study were T12-13, T13-L1 and T11-12. The mielography releasedsomo doubts, that have been resolved by CT; howeverthe CT showed doubts when there wasn´t soft-tissue mineralization in vertebral canal. When thre was a complete blockage of contraste because of contrast material the CT diagnoses the disc lesion because the presence of soft tissue mineralization vertebral canal. The methods of imaging diagnosis used complete each other and provided important information used to assess prognosis of the affected animals.
508

Padronização das tomadas radiográficas periapicais e panorâmicas com finalidade forense / Standards of periapical and panoramic radiographs for forensic examinations

Thiago Leite Beaini 18 June 2010 (has links)
Existem dificuldades envolvendo as radiografias para as técnicas comparativas de identificação humana. A falta de tecidos moles, o posicionamento do crânio e dos filmes representa obstáculos freqüentes durante as perícias antropológicas. Com objetivo de padronizar e obter imagens de qualidade e reduzir adaptações, testamos exposições, barreiras e outros aspectos radiográficos para a confecção de um protocolo envolvendo radiografias periapicais e panorâmica em crânios esqueletizados. Com a utilização de um dispositivo acrílico desenvolvido para posicionar o crânio, radiografias panorâmicas em diferentes configurações de potência do aparelho foram tomadas. Posteriormente, quatro objetos foram testados para compensar a falta de tecidos moles: uma bolsa térmica, um bloco de cera sete, uma placa de aço zincado e um filme, exposto à luz e processado, que foi mantido entre a película e a tela intensificadora. Para as radiografias periapicais, filmes do tipo E speed Kodak foram expostos por tempos variando entre 0,06 a 0,8 seg nas regiões de molares e incisivos em ambos os arcos. Os filmes foram fixados por posicionadores clínicos estabilizados por um suporte confeccionado com fios metálicos. O tempo de processamento foi de 45 seg de revelação e 10 min. de fixação. As radiografias foram apresentadas a quinze profissionais, de diferentes especialidades, que escolheram os melhores resultados, concluindo que as radiografias panorâmicas com a combinação de 63 Kv e 06 mA e com dois filmes presentes no chassi apresentou melhor qualidade e praticidade. Para as periapicais as exposições de 0,64 seg. no arco superior e 0,8 seg. no arco inferior obtiveram melhor aceitação. Com os resultados obtidos somados aos dados obtidos na literatura, um protocolo foi confeccionado e anexado a essa dissertação. / There are plenty of difficulties surrounding the radiographs for the comparative techniques on human identification. The lack of soft tissue, the skulls and films positioning are a few of the obstacles faced in anthropological studies. With the objectives to standardize, producing high quality images and reducing adaptations, different exposure times, barriers and other aspects involving radiographs were tested in order to establish a protocol involving periapical and panoramic radiographs of dry skulls. With the help of an acrylic stand, specially designed to position the cranium, panoramic radiographs were primarily taken using different preset configurations, then four materials were tested to compensate for lack of soft tissue: a ice pack, a block of dental wax, a metal plate and finally a film exposed to light and processed that was left between the blank film and the intensifying screen. For the periapical radiographs, Kodak E-speed films were exposed to times from 0.06 to 0.8 second at the upper and lower molars and anterior regions. Clinical film holders were used and kept in position by a metal wire device. The processing times were 45 seconds of development and 10 minutes of fixation. The radiographs were presented to a group of fifteen dentists, of several specialties, who selected the best results and concluding that the panoramic radiographs were best taken with the 63 Kv and 06 mA configurations and two films inside the cassette. For the periapical the exposure times of 0.64 sec for the upper arch and 0.8 sec for the lower achieved the best acceptance. The presented results, allied with the data found in the literature a protocol was also prepared and attached to this research.
509

Radiologia convencional e tomografia computadorizada na avaliação de cães portadores de discopatia cervical: estudo comparativo / Radiologic and computed tomographic evaluation of dogs with disc disease in cervical spine: a comparative study

Luciana Fortunato Burgese 04 August 2006 (has links)
Foram avaliados 25 cães portadores de discopatia cervical aos exames radiográficos simples, mielografia e tomografia computadorizada. A dor foi o principal sinal clínico em 64% dos casos. Os animais com raça definida foram os mais acometidos (85%), tendo maior incidência da raça Teckel. A faixa etária mais acometida foi entre 7-9 anos (72%). O exame radiográfico simples indicou aspectos compatíveis com extrusão em 14 observações. A mielografia diagnosticou 15 extrusões, 18 protrusões e 4 hérnias de disco e forneceu informações quanto ao grau de compressão medular e extensão das lesões. A tomografia computadorizada (TC) indicou 16 extrusões, 22 protrusões e 3 hérnias de disco. O espaço de C2-3 foi o mais acometido. A TC permitiu o diagnóstico de extrusões calcificadas, mesmo na presença de pouca quantidade ou ausência de meio de contraste e indicou com precisão o grau de compressão medular, a extensão e principalmente, a localização das lesões. Concluiu-se com este estudo que os três exames se complementam e constituem importantes ferramentas para o planejamento clínico-cirúrgico. / Twenty-five dogs with disc disease in cervical spine were evaluated by radiological and computed tomographic exams. The most common clinical signs were neck pain present in 64% of the dogs. Of the animals 85% were pure breed, amongst them Teckel were most frequent (28%). The most cases occurred in animals between seven and nine years. C2-3 was the preferred site of cervical involvement. Radiographic plain indicated fourteen extrusion. Myelography demonstrated fifteen extrusions, eighteen protrusions and four disc hernias and indicated spinal cord grade compression and lesions extension. Computed tomographic (CT) demonstred sixteen extrusions, twenty-two protrusions and three disc hernias. The CT showed to be more sensitive for soft tissue calcification, and his superior contrast resolution allowed visualization small quantities of contrast material in the subarachnoid space and indicated with precision the site and extension of lesions as well as the degree of spinal cord compression. The three exams are complementary and give valuable information for clinical and chirurgical procedures.
510

Utilização dos filtros da radiologia computadorizada para a avaliação da opacificação do forame intervertebral associada às hérnias de disco em cães / Use of computed radiology filters to evaluate the opacification of the intervertebral foramen associated with herniated disc in dogs

Luciana Fortunato Burgese Lanza 04 December 2012 (has links)
O processamento é uma das principais características da radiografia digital. Diante da frequência da discopatia em cães, a importância do exame radiográfico na investigação inicial desta doença e na orientação de outros exames de imagem (tomografia computadorizada, mielotomografia e imagem por ressonância magnética), buscou-se avaliar a efetiva contribuição das ferramentas de processamento da imagem no diagnóstico das hérnias de disco. Para tanto, foram avaliados 80 forames intervertebrais através da radiologia computadorizada pelos filtros padrão, invertido e realce de borda e a combinação entre esses (padrão e invertido, padrão e realce de borda e realce de borda e invertido) para pesquisa da opacificação do forame intervertebral associada às hérnias de disco em cães. A análise radiográfica foi realizada por dois avaliadores às cegas com tempo de experiência superior a 10 anos em radiodiagnóstico. Foram calculadas as medidas de sensibilidade, especificidade, valores preditivos positivos e negativos, acurácia e razão de verossimilhanças para os respectivos filtros e a combinação destes pelos dois avaliadores. A tomografia computadorizada foi tomada como padrão ouro da detecção de opacificação do forame intervertebral. O coeficiente de kappa e seu respectivo intervalo de 95% de confiança foram utilizados para analisar a concordância dos resultados. Os valores de sensibilidade obtidos pelos avaliadores foram de 58,7% na detecção das opacificações pelo filtro padrão, 52,2% pelo filtro invertido e 50% de sensibilidade no estudo realizado pelo filtro realce de borda. Na combinação entre os filtros padrão e invertido e realce de borda e invertido os valores foram os mesmos com 43,5%, sendo que a sensibilidade do filtro padrão associado com o filtro realce de borda foi de 50%. A acurácia alcançada na detecção das opacificações do forame intervertebral pelos filtros individualmente foi de 78,8% para o filtro padrão, 75% para o filtro invertido e 75,6% para o filtro realce de borda, não apresentando diferenças significativas quando a combinação entre os filtros foi realizada, obtendo-se 76,9% nas associações entre os filtros padrão e invertido e padrão e realce de borda e 75,6% através dos filtros realce de borda e invertido. O processamento da imagem digital pode aumentar a acurácia na detecção das opacificações do forame, no entanto os filtros podem somente realçar uma alteração existente e não aumentar a capacidade de detecção da lesão pelo exame radiográfico simples sendo necessária para tal, a associação de exames de imagem mais sensíveis (mielografia/tomografia computadorizada/ imagem por ressonância magnética). A preferência pessoal na utilização dos filtros também foi comprovada. / Processing is a major feature of digital radiography. Given the frequency of disc disease in dogs, the importance of radiographic examination in the initial investigation of this disease and the guidance of other imaging studies (computed tomography, myelography and magnetic resonance imaging), it was evaluate the effective contribution of the processing tools image in the diagnosis of herniated discs. For this, eigthy intervertebral foramina through were evaluated computed radiography by standart filters, reverse and edge enhancement and the combination of these (standard and inverted pattern, standard and edge enhancement and edge enhancement and inverted) in the investigation of opacification of the intervertebral foramen associated with hernia disc in dogs. Radiographic analysis was performed by two raters blind to time of more than 10 years experience in diagnostic radiology. It was calculated measures of sensitivity, specificity, positive and negative predictive values, accuracy and likelihood ratio for the respective filters and the combination of the two evaluators. Therefore, the CT scan was taken as the gold standard of detection opacification of the intervertebral foramen. The kappa coefficient and its corresponding interval of 95% confidence intervals were used to analyze the correlation of the results. The sensitivity values obtained by the evaluators were 58.7% in detecting the opacities of the standard filter, the filter inverted 52.2% and 50% sensitivity in the study by edge enhancement filter. In combination between standard and inverted filters and edge enhancement and inverted values were the same with 43.5%, and the sensitivity of the filter pattern associated with the filter edge enhancement was 50%. The accuracy achieved in the detection of opacities of the intervertebral foramen by the filters individually was 78.8% for the standard filter, 75% to inverted filter and 75.6% for edge enhancement filter, showing no significant differences when the combination between the filters was performed. yielding 76.9% associations between the filters standard and inverted pattern, and pattern and edge enhancement and 75.6% through the filter edge enhancement and inverted. The digital image processing can increase the accuracy in the detection of opacities foramen, however filters can only highlight a change and not increase the existing capacity of lesion detection by simple radiographic examination is necessary association of more sensitive imaging ( myelography / CT / MRI). Personal preference through the use of filters was also confirmed.

Page generated in 0.038 seconds