• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 393
  • 140
  • 74
  • 72
  • 4
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 686
  • 277
  • 276
  • 276
  • 276
  • 212
  • 191
  • 190
  • 62
  • 50
  • 49
  • 48
  • 47
  • 47
  • 47
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
461

Efeitos de raios-X de baixa energia em células mamárias / Effects of low energy x-rays in mammary cells

Flávia Ventura dos Passos 12 August 2011 (has links)
Doses de radiação de baixa energia podem induzir quebras de dupla fita no DNA assim como também produzir perfis alterados de expressão de genes relacionados a estas lesões. Os danos não reparados ou mal reparados levam a uma maior suscetibilidade à transformação oncogênica já que os efeitos biológicos mais importantes causados pela radiação ionizante são mutação e carcinogênese. As lesões no DNA provocadas pela radiação podem também ocasionar o surgimento micronúcleos e as células podem ser induzidas à apoptose. O objetivo deste trabalho é estudar in vitro a presença de micronúcleos e a apoptose ocasionados por Raios-X de baixa energia. Pretende-se analisar estes efeitos biológicos em relação à energia equivalente à utilizada em exames mamográficos usando duas linhagens estabelecias de células de mama: a MCF-7 (tumoral) e a HB-2 (não-tumoral). As células, em crescimento exponencial, foram irradiadas no equipamento de arranjo experimental de mamografia do LCR/UERJ. A dose de 5Gy na energia de 30 kV foi aplicada com taxa de 0,1 Gy/seg utilizando filtro de 0,03 mm de molibdênio. As irradiações foram realizadas duas vezes, após as irradiações, as células foram incubadas por 4, 24 ou 48 horas e posteriormente coradas com o corante Hoechst33258 para análise em microscopia de fluorescência. Para cada análise, 1000 células foram categorizadas pela morfologia do núcleo. Os resultados mostraram que a HB-2, utilizada neste estudo como célula mamária normal, apresentou maior sensibilidade aos efeitos da radiação, com 37 % das células em apoptose após 4 hs de incubação, enquanto a MCF-7 apresentou 6,5 %. Nas análises após 24 hs foi possível confirmar a radioresistência da MCF-7 tendo sido observadas 11% de células em apoptose no grupo irradiado. Houve um aumento crescente de micronúcleos radioinduzidos nas duas linhagens de acordo com os tempos de incubação. Na análise de 4 hs a HB-2 apresentou 3%, em 24 hs, 8,5% e 48 hs, 11,5 %. Diante destes resultados, foi possível concluir que a energia do feixe de raios-X utilizada na mamografia pode ser capaz de ocasionar aumento de ocorrência de apoptose e geração de micronúcleos nas duas linhagens estudadas / Radiation doses of low-energy can induce double-stranded breaks in DNA as well resulting in altered profiles of gene expression related to these injuries. The damage is not repaired or poorly repaired leading to increased susceptibility to oncogenic transformation since most important biological effects caused by ionizing radiation are mutation and carcinogenesis. The DNA lesions caused by radiation can also provoke the presence of micronuclei and as result cells can be induced to apoptosis. The aim of this work is to perform a preliminary study "in vitro" to identify the presence of micronuclei caused by low energy. X-rays. It is intended analyze these biological effects caused by x-rays with energy equivalent to the ones used in mammography in two very well established breast: cell lines the MCF-7 (tumor) and HB-2 (non-tumor). Cells in exponential growth were irradiated using an experimental arrangement with a mammography tube of the LCR / UERJ. The dose of 5Gy was used for 30 kVp x-rays using 0.03 mm filter molybdenum with a fixed dose rate of 0.1 Gy / sec. The irradiations were repeated twice and. the cells were incubated for 4, 24 or 48 hours and stained with dye Hoechst 33258 for fluorescence microscopy analysis. For each analysis 1000 cells were categorized by the morphology of the nucleus. The results revealed that the HB-2, used in this study as normal mammary cell have showed high sensitivity to the effects of radiation, with 37% of cells undergoing apoptosis after incubation of 4hs, while MCF-7 showed 6.5%. In the 24 hour-analysis it was confirmed the radiation resistance of MCF-7 were it was observed 11% of cells in apoptosis in the irradiated group. There was an increasing number of radiation-induced micronuclei in both cell lines, according to the incubation times. After 4 hours, HB-2 presented 3% of micronuclei, in 24 hours, the experiment reveled 8.5%, and after 48 hours it increased to 11.5%. As result of this study we may conclude that the energy used in mammography is capable to cause an increase in incidence of apoptosis and in the production of micronuclei in both cell lines studied
462

O profissional de enfermagem no serviço de hemodinâmica na perspectiva da ergonomia e proteção radiológica

Pereira, Aline Garcia January 2015 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia de Produção, Florianópolis, 2015. / Made available in DSpace on 2016-05-24T17:38:24Z (GMT). No. of bitstreams: 1 338952.pdf: 2285659 bytes, checksum: cc2c9de743c199f16aa70ed8a281379f (MD5) Previous issue date: 2015 / O serviço de hemodinâmica é uma modalidade da radiologia intervencionista, que possui como destaque os procedimentos de cateterismo e angioplastia, os quais requerem uma equipe multiprofissional que atua de forma multifuncional. Dentre esta, estão os profissionais da enfermagem, responsáveis pelos cuidados com o paciente, e estão expostos à radiação ionizante, assim como fatores ambientais e organizacionais do ambiente de trabalho. A proteção radiológica constitui-se como fator relevante para a saúde do trabalhador e do paciente, a partir do cumprimento de diretrizes, tais como: princípios da justificação, limitação de dose, otimização e prevenção de acidentes. No entanto, é necessário compreender a atividade de trabalho a ser analisada; para tanto, a ergonomia é uma aliada no estudo das relações homem-máquina-ambiente. Sendo assim, a presente pesquisa tem como objetivo analisar a atividade dos profissionais de enfermagem no serviço de hemodinâmica, e suas interações relacionadas à luz da ergonomia e da proteção radiológica. O procedimento metodológico da pesquisa constituiu-se de três principais fases, correspondente ao desenvolvimento de três artigos científicos. Na primeira fase (Artigo 1), foi realizada uma pesquisa bibliográfica referente à gestão na radiologia; a partir das constatações obtidas foi feito o levantamento do estado da arte especificamente do setor de radiologia intervencionista (Artigo 2), em seis bases de dados abordando os temas: radiologia intervencionista, enfermagem e ergonomia. Na terceira fase da pesquisa, foi realizado um estudo de caso (Artigo 3) a partir da metodologia de Análise Ergonômica do Trabalho com foco nas atividades da enfermagem, sendo o local de realização do estudo, uma clínica de Hemodinâmica de Florianópolis, SC. Como resultados pode-se observar que há falta de estudos sobre gestão na radiologia; além disso, dentre os principais problemas no setor estão: agenda, locomoção dos pacientes, localização dos materiais, peso dos aventais de chumbo, lombalgias, dores musculoesqueléticas, fadiga física e mental. Tais problemas ergonômicos destacam-se na literatura e foram constatados por meio do presente estudo de caso, interferindo nas questões organizacionais do setor e também no cumprimento dos princípios de proteção radiológica. Portanto, por meio da análise do sistema homem-máquina-ambiente da atividade de profissionais de enfermagem na hemodinâmica, pode-se concluir que a radiologia está em constante aperfeiçoamento, sendo que os problemas ergonômicos impactam na saúde e segurança dos profissionais de enfermagem, influenciando os princípios de proteção radiológica.<br> / Abstravt : Hemodynamic service is an interventional radiology modality, which highlight the procedures of catheterization and angioplasty, which require a multidisciplinary team that works on a multifunctional way. Among them are the nursing professionals, who are responsible for the care with the patient, and are exposed to ionizing radiation, as well as environmental and organizational factors of the working environment. The radiation protection constitutes a relevant factor for the health of the worker and the patient, from the compliance guidelines such as principles of justification, dose limitation, optimization and accident prevention. However, it is necessary to understand the analyzed work activity; therefore, ergonomics is an ally in the study of human-machine-environment relations. Thus, this research aims to analyze the nursing professionals? activity at hemodynamics service, and their interactions related to ergonomics and radiation protection. The methodological research procedure consisted of three main phases, corresponding to the development of three scientific articles. On the first step (Article 1), a literature research was conducted regarding the management in radiology; from the findings were made the research of state of art specifically on the interventional radiology sector (Article 2), in six different databases on the topics: interventional radiology, nursing and ergonomics. In the third was performed a case study (Article 3) with Ergonomic Analysis of Work metodology focused on nursing activities. The location of the study was in a catheterization clinic Florianópolis, SC. The results can show the lack of management studies in radiology; moreover, among the main problems in the sector are agenda, transportation of patients, location of materials, weight of lead aprons, back pain, musculoskeletal pain, physical and mental fatigue. Such ergonomic problems stand out in the literature and they were found through this case study, interfering in the sector's organizational matters and also in compliance with the radiation protection principles. Therefore, through the analysis of man-machine-environment system on nursing professionals at hemodynamics, it can conclude that radiology is in constantly improving, and the ergonomic problems influence the health and safety of nursing professionals, influencing radiation protection principles.
463

Protocolo Cyclops de Teleconferência

Mendes, John Anderson Freitas January 2004 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico.Programa de Pós-Graduação em Ciência da Computação / Made available in DSpace on 2012-10-22T04:17:22Z (GMT). No. of bitstreams: 1 222429.pdf: 1902461 bytes, checksum: 2a06d2c1067813bd2983a9b4294d55ba (MD5) / Este trabalho apresenta uma proposta de um protocolo de comunicação em nível de aplicação para possibilitar a realização de teleconferências radiológicas multiponto que seja compatível com redes de banda menor encontradas no interior de nosso país permitindo a transferência de pacotes de dados e imagens. O protocolo foi batizado de "Protocolo Cyclops de Teleconferência - PCT". Para validação do PCT, foi desenvolvido um sistema voltado a telemedicina ou especificamente para a área da teleradiologia. O sistema proposto denomina-se "Sala de Laudos Virtual Multiponto - SLVM", onde seu principal objetivo é compartilhar entre os usuários participantes de uma mesma sessão, arquivos de imagem no padrão DICOM 3.0 e suas ações durante a utilização do sistema. Durante toda a sessão de utilização do sistema, os usuários poderão se comunicar através de chat e também através voz sobre IP. O protocolo PCT permite a transferência apenas de dados referentes a ações dos usuários por chat, mouse e envio de arquivos DICOM. A aplicação desenvolvida para validar o protocolo, Sala de Laudos Virtual Multiponto, permite também a comunicação entre os participantes através de voz sobre IP, portanto, foi adotado um protocolo já existente denominado REMKO que transmite voz sobre conexões UDP. Esta solução permite a criação de um ambiente cooperativo entre médicos localizados geograficamente distantes, utilizando a tecnologia Internet existente para elaboração conjunta de laudos e diagnósticos dos pacientes através de informações e embasamento das imagens compartilhadas entre os membros participantes. O resultado final deste trabalho é um ambiente multiponto que permite que dois ou mais usuários médicos possam efetuar laudos em conjunto. Este sistema é parte integrante do projeto Cyclops Brasil onde possui cooperação binacional com a Universidade de Kaiserslautern da Alemanha com a Universidade Federal de Santa Catarina. A parceria objetiva o desenvolvimento de soluções voltadas para informática médica.
464

Um sistema de telemedicina de baixo custo em larga escala

Maia, Rafael Simon January 2006 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Ciência da Computação / Made available in DSpace on 2012-10-22T07:21:46Z (GMT). No. of bitstreams: 1 230930.pdf: 2350162 bytes, checksum: 481e636af6724066177de6bcd968c719 (MD5) / A Telemedicina é um serviço baseado na utilização dos recursos de comunicação e informática visando fornecer auxilio médico à distância para um paciente, fornecendo ferramentas para que um médico especialista realize sua função sem que seja necessário o contato direto entre eles. Para que um sistema de telemedicina seja funcional e adequado, é necessário entender a necessidade operacional e técnica, assim como delimitar que tipos de recursos são importantes para que o médico execute adequadamente seu trabalho, mesmo estando distante de seu ambiente normal de trabalho. Apresentamos aqui um modelo de rede de telemedicina em larga escala voltado para a realização de laudos a distância de exames de radiologia e cardiologia de acordo com a realidade, necessidades e capacidades operacionais e funcionais identificadas para o Estado de Santa Catarina. Demonstramos a viabilidade da utilização da infra-estrutura de rede e aparelhagem médica computadorizada já instalada para diminuir os custos de deslocamento de pacientes e o tempo de espera para a realização do laudo dos exames médicos auxiliados por computador, agilizando o atendimento médico aos pacientes. Garantimos a segurança, o armazenamento e a correta visualização dos exames, através da utilização de protocolos e padrões utilizados internacionalmente.
465

Transmissão e fluência de fótons na área de radiodiagnóstico para diferentes configurações de feixes e blindagens

Firmino, Sandro Fernandes January 2010 (has links)
Neste trabalho foi realizado um estudo da influencia das composições dos materiais de blindagem e variações nos espectros emitidos por equipamentos de raios X através da utilização de um programa computacional que utiliza a técnica de Monte Carlo. Foi determinada a fluência de fótons depois das blindagens, com geometrias realísticas de feixe primário, para espectros de energias utilizados na prática da radiologia diagnóstica, gerando, dessa maneira, um banco de dados representativos da transmissão média e fluência para os materiais estudados. Com o método proposto, busca-se analisar a influencia da composição da argamassa baritada, e do concreto em curvas de transmissão, bem como sua influencia na determinação da espessura de blindagem, e a influencia da alteração das características do espectro da radiação X na transmissão de fótons. A metodologia desse trabalho foi realizada em duas etapas distintas: a análise com dados de fluência e da transmissão com espectros monoenergéticos e polienergéticos, mantendo-se as mesmas configurações das geometrias internas de simulação, como por exemplo, a filtração total, o ripple e o ângulo efetivo do feixe, mas considerando um material de blindagem para o espectro monoenergético e três materiais para o espectro polienergético; a intercomparação entre o mesmo material de blindagem, através da alteração da filtração total, do ripple, e do ângulo de voo da geometria interna de simulação. Como resultado, foi possível analisar os dados simulados, apresentando diferenças aparentemente significativas entre os dados das transmissões médias de fótons, devido às diferentes composições, mas estas diferenças não são significativas a ponto de influenciarem nas estimativas das espessuras das blindagens na construção civil. Este trabalho também apresenta um banco de dados contendo as fluências de radiação X, depois das blindagens para as diferentes configurações de feixe e materiais da parede, e um banco de dados contendo as curvas e suas equações de ajuste das curvas de transmissão para os diferentes materiais estudados. A avaliação da alteração da transmissão em função de variações no espectro de emissão de radiação X demonstrou grande importância para a influencia destes fatores na formação do espectro. As alterações nas composições do espectro, devido às variações da filtração total de alumínio, aumentaram o poder de penetração no material absorvedor e em sua energia média do feixe. As mudanças na composição do espectro devido a alterações do ângulo de inclinação do anodo e do ripple, evidenciaram seu grau de influencia nas estimativas das curvas de transmissão de fótons X, onde o aumento do ângulo efetivo e do ripple no espectro aumenta a participação de fótons de baixa energia, e diminui a energia média do feixe e a camada semirredutora, tendo uma participação diferenciada na formação da imagem radiográfica. Trabalhos futuros poderão ser realizados com simulações de maior número de pontos de espessuras e de histórias, possibilitando uma melhor estatística dos dados simulados, minimizando assim os erros relativos. Além disso, sugere-se que esse método seja aplicado a diferentes materiais e composições de materiais utilizados na construção de blindagens, com o intuito de gerar um banco de dados que auxilie na proteção radiológica na área da radiologia geral. / This work presents a study of the influence of the compositions of shielding materials and variations in the spectra emitted by X-ray equipment by using a computer program that uses the Monte Carlo technique. The flux of photons was determined after the shielding material, with realistic geometries of the primary beam energy spectra used in the practice of diagnostic radiology, generating in this way, a database representative of the average transmission and fluence for the materials studied. With the proposed method, we seek to analyze the influence of barium composition of the mortar, and concrete transmission curves and their influence in determining the shielding thickness, and the influence of altering the characteristics of the radiation spectrum in the transmission of X photons. The methodology of this study was conducted in two stages: analysis with data streaming and transmission spectra with monoenergetic and polienergetics beams, keeping the same settings of the internal geometry of the simulation, for example, the total filtration, the ripple and the effective angle beam, although considering a shielding material for the monoenergetic spectrum and three materials for the polienergetic spectrum; the intercomparison between the same shielding material by changing the total filtration, ripple, and the angle of flight of the internal geometry simulation. As a result it was possible to analyze the simulated data, presenting among mean transmission data of photons, due to different compositions, but these differences are not significant enough to influence the thicknesses of shielding estimation used in the construction industry. This work also presents a database containing the fluence of X-irradiation, the shielding for the various beams and wall materials, and a database containing the curves and their equations to fit the curves of transmission for different materials studied. The evaluation of the change in transmission due to variations in the emission spectrum of X-rays showed great importance on the influence of these factors in the formation of the spectrum. Changes in the composition of the spectrum, due to variations in the total aluminum filtration, increased the power of penetration into the absorbing material and its average energy. Changes in the composition of the spectrum due to changes in the angle of the anode and the ripple, showed their influence in the estimation of transmission curves of X-photons, where the increase in the effective angle and ripple in the spectrum increases the participation of low energy photons, and decreases the average energy of the beam and half-value layer, and a differentiated participation in the formation of radiographies. Future work will be carried on simulations of many points of thicknesses and stories, allowing a better statistical analysis of simulated data, thus minimizing the relative errors. Moreover, it is suggested that this method be his applied to different materials and compositions of shielding materials in order to generate a database to assist in radiological protection in the field of general radiology.
466

Anormalidades ultrassonográficas e radiográficas em joelhos de cavalos da raça Quarto de Milha da linhagem de apartação

Cisneros Álvarez, Luis Emiliano [UNESP] 22 July 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-07-22Bitstream added on 2014-06-13T20:21:55Z : No. of bitstreams: 1 cisnerosalvarez_le_dr_botfmvz_parcial.pdf: 65686 bytes, checksum: 530a086d56883c9840daa9ac2438300b (MD5) Bitstreams deleted on 2015-06-03T11:42:25Z: cisnerosalvarez_le_dr_botfmvz_parcial.pdf,. Added 1 bitstream(s) on 2015-06-03T11:43:59Z : No. of bitstreams: 1 000725204_20150701.pdf: 57235 bytes, checksum: 80f1b72c7d09a211613e02a4138e8c82 (MD5) Bitstreams deleted on 2015-07-01T11:47:26Z: 000725204_20150701.pdf,. Added 1 bitstream(s) on 2015-07-01T11:48:08Z : No. of bitstreams: 1 000725204.pdf: 1427769 bytes, checksum: 7c4af9251cf29f288c34d0f0aa056d71 (MD5) / A apartação é uma das competições mais populares na qual o cavalo Quarto de Milha é utilizado. Embora as lesões nas articulações femorotibial e femoropatelar sejam frequentes nessa modalidade esportiva, não foram publicados trabalhos que relatem os achados ultrassonográficos e radiográficos em animais submetidos a treinamento intensivo ou competição. Assim, o objetivo deste trabalho foi investigar a ocorrência de anormalidades ultrassonográficas e radiográficas nas articulações femorotibial e femoropatelar em cavalos de apartação da raça Quarto de Milha submetidos a treinamento intensivo. Foram realizados exames ultrassonográficos, radiográficos e testes de flexão bilaterais dos joelhos de cavalos Quarto de Milha de apartação sem claudicação aparente para o treinador, com idades entre 38-47 meses (grupo treinamento, TG) e maiores do que 47 meses (grupo competição, CG). As anormalidades ultrassonográficas, radiográficas e presença de claudicação antes e após teste de flexão foram categorizadas e as frequências calculadas e comparadas entre os grupos. Foram identificadas anormalidades ultrassonográficas em 100% dos animais avaliados, sendo a sinovite a entidade nosológica mais comum (89,3%, dos animais avaliados), seguida pela rarefação de menisco medial (64,3%) e desmite de ligamento colateral medial (33,9%). Nas radiografias foram identificadas anormalidades em 59,5% dos animais, sendo os animais jovens os que apresentaram maior ocorrência de lesões (P<0,05). Houve também diferença significativa entre o número total de animais com claudicação antes e após o teste de flexão. Não foi detectada associação entre o tipo de lesões nos meniscos e o grau de claudicação. Conclui-se que existe uma proporção alta de anormalidades ultrassonográficas e radiográficas nos joelhos de cavalos Quarto de... / Cutting is one of the most popular uses of the Quarter Horse. Although lesions to the femorotibial and femoropatellar joints are common in this sport, no studies have been published on the ultrasonographic and radiographic findings in cutting Quarter Horses. The aim of this study was to investigate the occurrence of ultrasonographic and radiographic changes in the stifles of cutting horses, either training or competing. Ultrasonographic, radiographic and flexion test examinations were performed in the stifles of cutting horses, aging 38-47 months (training group, TG) and older (competition group, CG). Lameness should not have been realized by the horse's trainer/owner. Ultrasonographic, radiographic and lameness findings after and before flexion test were categorized and their frequencies compared between groups. Ultrasonographic changes were identified in 100% of the horses. The most frequent finding was synovitis (89.3% of the animals), followed by rarefaction of the medial meniscus (64.3%) and desmitis of the medial collateral ligament (33.9%). Radiographic changes were identified in 59.5% of the animals, with the younger horses suffering from a higher number of abnormalities (P<0.05). There was also a significant difference between the overall number of lame horses before and after flexion test. Association between type of meniscal lesion and degree of lameness was not observed. We concluded that there is a high proportion of ultrasonographic and radiographic changes in the stifle of cutting Quarter Horses. Likewise, radiographic changes are most commonly found among younger horses... (Complete abstract click electronic access below)
467

Estudo das correlações entre lesões ósseas podais diagnosticadas pela radiografia com o peso vivo, circunferência torácica, D.M.O.(determinada por densitometria óptica radiográfica)concentrações séricas de Ca, P, Mg, Zn, Fosfatase Alcalina, Proteínas Plasmáticas totais, Globulina, Creatina quinase, GamaGlutamiltransferase, Albumina, Aspartato-aminotransferase, Osteocalcina, pH do Rúmen e Hemograma em bovinos fêmeas da raça Nelore, sem sintomas clínicos de doença podal

Scudeller, Paulo Sergio de Oliveira [UNESP] January 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:10Z (GMT). No. of bitstreams: 0 Previous issue date: 2005Bitstream added on 2014-06-13T19:01:30Z : No. of bitstreams: 1 scudeller_pso_dr_botfmvz.pdf: 2044336 bytes, checksum: 533c13f118e2a550bd3a71ed20c31cc2 (MD5) / A doença podal é considerada como a terceira mais importante enfermidade nos bovinos leiteiros, após mastite e problemas reprodutivos, levando a uma perda econômica e financeira significativa. Pesquisadores observaram uma correlação negativa de enfermidades podais com produção leiteira e com a eficiência reprodutiva. O propósito deste estudo foi conhecer a ocorrência, tipo e grau de enfermidades falangeanas assintomáticas diagnosticadas pela radiografia, de fêmeas da espécie bovina Bos indicus, da raça Nelore, provenientes do Centro Nacional de Pesquisa do Gado de Corte da EMBRAPA do município de Campo Grande - MS, criadas em sistema extensivo, pastagem de Brachiaria decumbens, com suplementação mineral e controle sanitário e parasitário rigorosos, e correlacionar o grau de alterações ósseas com o peso vivo, circunferência torácica, DMO, proteínas totais, CK, GGT, albumina, globulina, AST, Ca, P, Mg, Mn, Zn, fosfatase alcalina, osteocalcina, leucograma e o pH rumenal. Foram radiografados os cascos dos quatro membros nas posições dorso-palmar, dorso-plantar e látero-medial e o terceiro osso metacarpo na posição dorso-palmar para avaliação densitométrica. Pela avaliação estatística, não ocorreu correlação entre as variáveis obtidas e lesões ósseas podais. Apenas ocorreu correlação entre idade e presença de exostose podal. Ficou comprovada a importância do exame radiográfico como imprescindível meio de diagnostico para a laminite assintomática. / The pedal disease has been as the third most important disease in dairy cattle, after mastitis and reproduction problems, with a significant economical and financial loss. Workers observed a negative correlation of feet diseases with dairy yield and reproductive performance. The purpose of this study was know the occurrence and type and degree of pathological bone chances in phalangies without clinical signs diagnosed through radiographic examine of bovine females species Bos indicus, from Center National of Research of Beef Bovine, EMBRAPA, city Campo Grande - MS, husbandry in extensive system, pasture of Brachiaria decumbens, with mineral supplement and rigorous parasitic and sanitary control; and to correlate the degree osseus changes with weight, toracic circumference, BMD, Protein total serum, CK, GGT, Albumin, Globulin, AST, Ca, P, Mg, Mn, Zn, Alkaline Phosphatase, Osteocalcin, White blood cells and ruminal pH. The claws of fore and hind of cows were radiographed in dorso-palmar, dorso-plantar and latero-medial views, and the bone metacarpus was radiographed in dorso-palmar view to evaluation densitometric. With statistical analysis did not occur correlation between samples obtained and pedal bone lesions. Occur correlation between age and pedal exostosis. It was confirmed the importance of radiographic examine as recourse diagnosis indispensable to subclinic laminitis.
468

Estudo dos aspectos anatômicos da articulação temporo-hióide de equinos por meio da radiografia convencional, ultrassonografia articular e tomografia computadorizada

Santos, Taízha Cristine Ciasca dos [UNESP] 26 February 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:28Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-02-26Bitstream added on 2014-06-13T21:02:31Z : No. of bitstreams: 1 santos_tcc_dr_botfmvz.pdf: 1078653 bytes, checksum: 71dcb57b72b60adc7f65bce0c64a9458 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Este estudo teve como objetivo, utilizando para tanto 22 cabeças de cadáveres equinos sadios, obtidas em abatedouro frigorífico, avaliar comparativamente de forma minuciosa e detalhada a anatomia da articulação temporo-hióide de equinos, por meio do exame radiográfico convencional, ultrassonográfico articular e tomográfico. Ambas as articulações, direita e esquerda, foram avaliadas. As imagens obtidas pelos três métodos foram identificadas e agrupadas sob aspecto das imagens que se repetem, que se somam e que se complementam, além da realização de avaliação minuciosa das características anatômicas da articulação temporo-hióide como um todo pelos diferentes acessos diagnósticos, buscando o meio de diagnóstico menos agressivo, não invasivo, rápido e de relativo baixo custo quando comparados. Observou-se que a tomografia visibilizou sempre de forma clara, ou seja, com melhor qualidade e precisão, todas as características e estruturas avaliadas. Já o raios-x e a ultrassononografia variaram bastante, algumas vezes de forma positiva, em concordância com a tomografia, outras nem tanto, limitando a avaliação de determinadas estruturas por estes métodos. Os três métodos de diagnóstico demonstraram uma concordância plena significativa (93,18%) apenas em relação à sua localização anatômica, o que não significa que os três métodos não podem gerar informações adicionais de grande valia. Concluiu-se que a TC é superior aos outros métodos, porém os três podem ser aliados no sentido de que se complementam, repetindo e somando imagens e informações importantes na escolha de um tratamento e na avaliação de seu prognóstico. Estes resultados propõem referências de abordagem que adicionarão informações na avaliação da região da articulação temporo-hióide dos equinos. / Twenty-two equine heads obtained from healthy slaughtered horses were analyzed through conventional radiography, articular ultrasonography and Computed Tomography (CT). Both left and right joints were evaluated. Images obtained by the three methods were identified and grouped according to different aspects: repeated images, added images and complementary images. In addition, images were thoroughly evaluated for anatomical characteristics of the temporohyoid joint as a whole by the different diagnostic accesses, in an attempt to obtain a less aggressive, non-invasive, fast and relatively inexpensive diagnosis. Tomography always showed the evaluated characteristics and structures very clearly, i.e., with better quality and precision. In contrast, x-ray and ultrasonography varied significantly, sometimes positively, in agreement with tomography, and in other instances negatively, limiting the evaluation of certain structures by those methods. The three diagnostic methods showed a significant concordance (93.18%) only in relation to the anatomical localization. This, however, does not mean that the three methods may not generate additional useful information. It was concluded that CT is a superior method than the others, although the three methods are complementary and can be combined, by repeating and adding important images and information when choosing a treatment and in the evaluation of the prognostics. These results define a reference of access that will add information in the evaluation of the equines temporohyoid joint. tomography, articular ultrasonography.
469

Leishmaniose visceral canina: estudo imagiológico em cães naturalmente infectados / Canine visceral leishmaniasis: imaging study in naturally infected dogs

Silva, Alexandre Redson Soares da [UNESP] 28 March 2014 (has links) (PDF)
Made available in DSpace on 2015-05-14T16:53:17Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-03-28Bitstream added on 2015-05-14T16:59:04Z : No. of bitstreams: 1 000822331.pdf: 1554623 bytes, checksum: 733126bd470d0b2e838cbf2e48edbcc0 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Alterações locomotoras são incomuns em cães com leishmaniose visceral. Embora a origem dos sinais clínicos permaneça obscura, a poliartrite deve ser considerada como um potencial diagnóstico nestes casos. Muitos agentes etiológicos podem causar poliartropatias, sendo estas classificadas em não inflamatórias e inflamatórias. Acredita-se que a poliartrite induzida por Leishmania spp. seja decorrente de uma reação inflamatória granulomatosa, causada pela presença de parasitos ou por uma resposta celular e humoral. O diagnóstico clínico ainda é um desafio para os profissionais de saúde, devido à grande variedade de sinais inespecíficos em decorrência da leishmaniose visceral. Desta forma, o presente trabalho teve como objetivos avaliar radiotomograficamente as articulações umeroradioulnares, radiocarpicametacárpicas, femurotibiopatelares e tibiotarsicametatársicas, a fim de caracterizar as lesões osteoarticulares, fornecendo subsídios para os clínicos que atuam em áreas endêmicas. Para tanto, foram utilizados 46 cães, naturalmente infectados, com diagnóstico firmado por meio dos exames imunocromatográfico (95,65%), ELISA (97,82%) e/ou parasitológico direto (95,65%), provenientes do Centro de Controle de Zoonoses de Bauru. Não houve predileção quanto ao sexo (1:1). A maioria dos animais não apresentava precisa definição racial (78,26%). A idade variou entre um a 12 anos, com mediana igual a três anos. Sinais clínicos compatíveis com poliartrite foram observados em 32,60%. Alterações radiográficas e tomográficas importantes foram observadas em 77% e 91% dos caninos, respectivamente, sendo as articulações tibiotarsicametatársicas a mais afetada em ambos os testes, acomentendo cães sintomáticos e assintomáticos. Os sinais imaginológicos foram variados, não sendo possível determinar um padrão específico para a doença, porém a presença de trabeculado ósseo evidente, ... / Locomotor alterations are uncommon in dogs with visceral leishmaniasis (VL). Although the origin of clinical signs remain unclear, polyarthritis should be considered as a potential diagnosis in these cases. Many etiological agents may cause polyarthropathies, which are classified into inflammatory and non-inflammatory. It is believed that the polyarthritis induced by Leishmania spp. may be due to a granulomatous inflammatory reaction caused by the presence of parasites or by cellular and humoral response. Clinical diagnosis is still a challenge for health professionals, due to the great variety of nonspecific clinical signs on VL. Thus, the aim of the present study were to evaluate radiographically and tomographically elbows, carpal, stifle and tarsal joints, in order to characterize the osteoarticular lesions, providing subsidies for veterinary practitioners in endemic areas. For this, 46 dogs were used, naturally infected, with diagnosis confirmed by immunochromatography (95.65%), ELISA (97.82%) and/or cytological (95.65%) methods, from the Zoonoses Control Center of Bauru. There was no preference to gender (1:1). The majority of animals were mixed breed (78.26%). Ages varied from 1 to 12 years, with a median of 3 years. Clinical signs consistent with polyarthritis were observed in 32.60%. Radiographic and tomographic alterations were observed in 77% and 91% of dogs, respectively, with tarsal joints the most affected on both methods, on asymptomatic and symptomatic dogs. Imaging signs varied, and it was not possible to establish a pattern for the disease, however the presence of apparent trabecular bone, bone sclerosis and osteolysis were the most frequently observed. Furthermore, we noticed a tendency for bilateral and symmetric involvement. It was observed a lack of significance when comparing the radiographic and tomographic lesions between symptomatic and asymptomatic ... / FAPESP: 12/02484-2
470

Desenvolvimento e construção de um fantoma homegêneo de mão para otimização de imagens radiográficas

Pavan, Ana Luiza Menegatti [UNESP] 28 February 2014 (has links) (PDF)
Made available in DSpace on 2014-08-13T14:50:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-02-28Bitstream added on 2014-08-13T17:59:54Z : No. of bitstreams: 1 000769600.pdf: 1575517 bytes, checksum: 984a7c3b764225da6366789021db60c8 (MD5) / A Radiologia Computadorizada (CR – do inglês Computed Radiology) tem sido amplamente utilizada para auxiliar o diagnóstico médico em hospitais e clínicas em todo o mundo. Entretanto a rotina clínica comumente utiliza cartas de técnicas empregadas em sistemas tela-filme na aquisição de imagens em sistemas de detecção CR. As normativas internacionais já estabeleceram parâmetros de testes de controle de qualidade em CR. Entretanto as normativas nacionais trabalham para essa construção. Estudos recentes apontam métodos de otimização de imagens em sistema de detecção CR para exames de crânio, pelve e tórax para pacientes adulto e padrão sem se reportarem a exames de mão. Muitas doenças que acometem as mãos hoje em dia utilizam o exame de raios X como exame auxiliar para diagnóstico. Vale salientar que a técnica utilizada deve fornecer imagens com o máximo de informações possíveis para um diagnóstico seguro, com a menor dose ao paciente, e com redução de custos para a instituição onde os exames são realizados. Neste estudo um fantoma homogêneo de mão foi desenvolvido para ser utilizado no processo de otimização de imagens de mão utilizando sistema CR. Nesse procedimento foram quantificadas as espessuras de distintos tecidos que constituem um fantoma antropomórfico de mão a partir de exames de tomografia computadorizada. O mesmo procedimento foi adotado para 30 exames retrospectivos de pacientes do Hospital das Clínicas da Faculdade de Medicina de Botucatu- UNESP (HCFMB-UNESP). Os resultados obtidos apresentaram concordância entre as espessuras de tecidos que constituem o fantoma antropomórfico e a amostragem de pacientes avaliados, apresentando variações entre 12,63% e 6,48% para tecidos moles e ósseos, respectivamente. O fantoma homogêneo foi utilizado no processo de calibração do feixe de raios X, produzindo técnicas testes. Essas técnicas foram aplicadas em um fantoma antropomórfico de ... / Computed Radiology (CR) has been widely used to assist medical diagnosis in hospitals and clinics worldwide. However clinical routine commonly use charts of techniques used in screen-film systems to obtain images in the detection CR systems. The international standards already established parameters of quality control tests in CR. However the national normative work for this construction. Recent studies suggest methods for optimizing images on CR systems for skull, pelvis and thorax exams for adult standard patients without reporting the exams of hand. Many diseases affecting hands today use the X-ray examination as an aid to diagnosis. It is noteworthy that the technique should provide images with maximum possible information for a safety diagnosis, with the lowest dose to the patient, and cost savings to the institution where the exams are performed. In this study a homogeneous phantom hand was developed to be used in the optimization of hand images using CR system. In this procedure were quantified thicknesses of different tissues that constitute an anthropomorphic phantom hand from CT scans. The same procedure was adopted for retrospective examinations of 30 patients of the Hospital das Clinicas, of School Medicine of Botucatu, UNESP (HCFMB-UNESP). The results showed agreement between the thicknesses of tissues that constitute the anthropomorphic phantom and sampling of patients, presenting variations between 12.63% and 6.48% for soft tissue and bone, respectively. The homogeneous phantom was used in the calibration of the X-ray beam process, producing tests technical. These techniques were applied in an anthropomorphic phantom hand from CT scans. The same procedure was adoped for retrospective examinations of 30 patients of the Hospital das Clinicas, of School Medicine of Botucatu, UNESP (HCFMB-UNESP). The results showed agreement between the thicknesses of tissues that constitute the anthropomorphic phantom and sampling of ...

Page generated in 0.0442 seconds