• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 393
  • 140
  • 74
  • 72
  • 4
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 686
  • 277
  • 276
  • 276
  • 276
  • 212
  • 191
  • 190
  • 62
  • 50
  • 49
  • 48
  • 47
  • 47
  • 47
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
541

Evolució temporal de la ingesta dietètica de contaminants ambientals per la població catalana. Estudis de dieta total i duplicada .

Martorell Mariné, Isabel 30 October 2013 (has links)
La present tesi doctoral forma part del projecte d'Estudi de Dieta total (TDS) de contaminants químics a Catalunya. L'EFSA estableix que els TDS proporcionen estimacions precises d'exposició sobre una població representativa. Un TDS consta: Selecció de mostres, recollida, homogeneïtzació, anàlisi i tractament de dades. Altrament, l'OMS inclou la metodologia de Dieta Duplicada (DD), aquesta presenta les mateixes característiques que el TDS, a excepció que els homogeneïtzats són porcions duplicades d'una dieta tipus. Els contaminats seleccionats van ser: Hidrocarburs Aromàtics Policíclics (HAPs), Arsènic, Cadmi, Mercuri, Plom i Substàncies Perfluoralquilades. L'estudi d'HAPs es va realitzar per TDS i DD. La selecció d'aliments va ser condicionada per l'última enquesta alimentaria realitzada a Catalunya. RESULTATS: Les ingestes dels contaminats es troben en tots els casos per sota de les recomanacions establertes per organismes oficials. Valorant els resultats obtinguts d'HAPs: La DD pot ser una bona alternativa al TDS, especialment quan existeixen limitacions econòmiques. / This thesis is part of the Total Diet Study project (TDS) of pollutants in Catalonia. The EFSA established that TDS provides the results or value of exposure on a representative population. A TDS consist of: Sampling selection, collection, homogenization and data analysis. Otherwise, the WHO includes the Duplicate Diet's methodology (DD). The DD has the same characteristics of the TDS, with the particularity that homogenized are menus based on normal mixes diets. The pollutants selected were: Polycyclic Aromatic Hydrocarbons (PAHs), Arsenic, Cadmium, Mercury, Lead, and Perfluoroalkyl Substances. The study of PAHs was done for TDS and DD. The food selection was conditioned by the most consumed raw products of Catalonia (Spain). Results: The dietary intake of all pollutants is situated below the recommendation established by government agencies. According to the results of PAHs for both methodologies DD studies might be a good alternative, especially when economic limitation are present.
542

La dependencia del alcohol: una comparación crítica sobre los tratamientos de dicha dependencia desde modelos biomédicos y espiritualistas

Esteve Blanch, Jaume 14 November 2013 (has links)
A través de un trabajo de campo realizado básicamente en la ciudad de Barcelona (2009-2011), mediante observación participante en tres Grupos de Alcohólicos Anónimos y en dos Centros biomédicos de recuperación de la dependencia del alcohol, se refieren de forma autoetnográfica los procesos terapéuticos y las narrativas de los participantes en ambas instituciones, analizando las semejanzas y las singularidades observadas. La estratificación social de dichos centros permite plantear una valoración socio-cultural de las dinámicas grupales observadas, la etiología de determinados casos de adicción y los resultados terapéuticos. Se confirma la hipótesis principal consistente en la validación de los grupos terapéuticos como el método más efectivo del tratamiento de deshabituación alcohólica, aún cuando se matizan los diferentes enfoques de dicha terapia así como el back-ground ideológico que se observa en ciertas orientaciones institucionales. Las dos hipótesis secundarias se ven reforzadas de forma diversa: se confirman las estrategias de autodisculpa, que suelen formar parte de las narrativas y actitudes de la mayor parte de usuarios estudiados, en especial al comienzo del tratamiento, si bien no se puede validar la memoria adictiva, con anclaje en los inicios del consumo, como un elemento de importancia durante la terapia. / A fieldwork project has been conducted, by and large in Barcelona city (between 2009 and 2011), involving participatory observation of three Alcoholics Anonymous groups and two biomedical alcohol abuse rehab centres. The aim is to provide a self-ethnographic overview of the therapy processes and the accounts of the participants in both types of settings, analysing the similarities and unique aspects observed. Social stratification of those centres makes it possible to undertake a sociocultural assessment of the group dynamics observed, the aetiology of certain addiction cases and the outcomes of the therapy administered. The main hypothesis, entailing the corroboration of therapy groups as the most efficient means of treating alcohol abuse, is supported. This is the case even when the various approaches to said therapy and the ideological background observed in certain institutional orientations are examined in greater depth. The two secondary hypotheses are strengthened in varying manners: self-forgiveness strategies, which are often part of accounts and attitudes among most users studied, are confirmed, especially at the start of treatment; however, addictive memory, embedded in the outset of consumption, cannot be validated as an element of significance during therapy.
543

Multi-scale investigation of occurrence, fate, removal and biodegradation of pharmaceutical contamination in wastewater treatment and river systems

Collado Alsina, Neus 19 July 2013 (has links)
Human and veterinary pharmaceuticals have been recognized as ubiquitous water microcontaminants with potential subtle detrimental effects on aquatic organisms. The majority of pharmaceutical compounds, after being consumed and excreted, end up in municipal WWTPs, which are not typically designed for complete pharmaceutical removal. Therefore, effluents from WWTPs constitute a low concentration, but continuous source of pharmaceutically active compounds to the aquatic environment. The main objective of the thesis is to acquire and provide with knowledge not only on the occurrence of pharmaceutical compounds in wastewater, but on their biodegradation within WWTPs and their discharge into the receiving media. The obtained results demonstrate conventional wastewater treatment’s variable efficiency when removing the pharmaceutical compounds load and the advance treatment’s contribution to their overall removal. It has also been possible to model the behaviour of a selected pharmaceutical and its transformation products. And it also includes investigation of an antibiotic’s impact on the bacterial community performance, and the antibiotic resistance genes phenomenon. Finally, the role and usefulness of proteomics when investigating the possible proteins involved on the biodegradation pathways of certain pharmaceutical compounds / Els compostos farmacèutics d’ús humà i animal s’han identificat com a microcontaminants aquàtics omnipresents amb possibles efectes nocius sobre el medi ambient. La major part d’aquests compostos, un cop consumits i excretats, van a parar a les EDARs, que no estan dissenyades per eliminar-los completament. En conseqüència, els efluents d’aquestes esdevenen un flux, poc concentrat però constant, de fàrmacs cap al medi aquàtic. L’objectiu principal d’aquest treball és el d’adquirir i proporcionar coneixement pel que fa tant a la presència d’aquests compostos farmacèutics a les aigües residuals, com a la seva degradació en EDARs i la seva descàrrega al medi receptor. Els resultats obtinguts demostren la variabilitat en l’eficàcia dels tractaments convencionals d’aigües residuals i la contribució dels processos avançats a l’hora d’eliminar els fàrmacs. També s’ha aconseguit modelar el comportament d’un fàrmac i dels seus productes de transformació. S'ha abordat també, l’impacte d’un antibiòtic sobre la comunitat bacteriana a nivell microbiològic i el fenomen dels gens de resistència antibiòtica. I, finalment, el paper de tècniques proteòmiques a l’hora de buscar possibles proteïnes involucrades en el procés de biodegradació de certs compostos farmacèutics
544

Avaluació de la genotoxicitat en el medi terrestre: utilització de l'electroforesi de cèl·lules individuals en gels d'agarosa (Comet test, o SCGE).

Delgado Sureda, Eulàlia 19 December 2001 (has links)
Estudi de l'avaluació de la possible contaminació de tipus genotòxic en l'abocador de Garraf (Barcelona), el qual recull els residus urbans de Barcelona i de les seves rodalies. Es va dur a terme el "Comet Test" (o SCGE: "Single Cell Gel Electrophoresis Assay") i el Test dels Micronuclis (MNT) en mostres de sang d'Apodemus sylvaticus (capturats a diferents àrees de l'abocador, i en una zona control lluny de la influència d'aquest i que pertany al Parc Natural del Garraf). Al mateix temps, es va aplicar la tècnica del Comet test en mostres de celomòcits d'exemplars d'Allolobophora caliginosa exposats a mostres de sòls procedents de l'abocador (5 zones situades a diferents distàncies d'aquest), i a mostres control. Per a les dues espècies utilitzades i els dos assaigs realitzats (SCGE i MNT en Apodemus, i SCGE en Allolobophora) es van obtenir valors majors de dany al DNA en les mostres de les zones d'influència de l'abocador respecte a les mostres control. No es va poder establir, pel cas dels lumbrícids, una relació del nivell de dany en relació a la distància a l'abocador (s'esperava una disminució dels valors, un apropament als valors control, quan les mostres fossin recollides més lluny de l'abocador). Mentre que en el cas dels ratolins, els valors corresponents a la zona més allunyada eren significativament menors que els obtinguts al voltant de la bassa de lixiviats. Les dues espècies, autòctones i abundants, poden servir com a bons sentinelles per a l'avaluació de la contaminació en l'abocador (tot i que en el cas dels lumbrícids utilitzats la interpretació pot ser més complicada).Un altre estudi es va centrar en l'avaluació de la contaminació de tipus genotòxic en mostres de sòl de Doñana, recollides l'any 2000 en diferents zones afectades pel vessament tòxic de l'accident de les mines d'Aznalcóllar de l'abril del 1998. Es van exposar varis exemplars d'Allolobophora caliginosa a les diverses mostres de sòl, i es va dur a terme el SCGE en celomòcits. Al mateix temps es van comparar els resultats obtinguts pel SCGE amb la concentració de metalls pesants mesurada en les mostres de sòl. Les mostres contaminades pel vessament tòxic i les mostres de referència de la mateixa zona (suposadament no afectades pel vessament) indiquen valors superiors amb el "Comet test" als de les mostres control. Una part molt important del treball realitzat es va basar en aspectes tècnics de l'assaig del cometa ("Comet test"), per poder conèixer una mica més el seu funcionament a nivell fisiològic i molecular. Així es van realitzar diversos estudis "in vitro" i "in vivo" per veure la possible interferència de la divisió cel·lular en els resultats del SCGE. Altres proves han estat dirigides a veure la relació que pot existir entre els resultats del SCGE i els estats d'apoptosi i necrosi de les cèl·lules, els quals podrien causar una interferència (de tipus citotòxic) en els resultats de l'assaig. Un altre estudi està centrat en el seguiment de la cinètica de reparació. A determinades dosis d'una substància genotòxica (òxid d'estirè) a les que es podia observar un nivell de dany al DNA (mesurat amb el "Comet test"), al cap d'un determinat temps es podia veure una disminució d'aquest dany, atribuïble a la reparació, tant en experiments "in vivo" com "in vitro". La incubació de les mostres amb l'enzim de reparació Endonucleasa III permetia augmentar la sensibilitat del test, detectant lesions de tipus oxidatiu, i d'altres, a més de les normalment detectades amb el "Comet test" sense l'ús d'aquests enzims. En aquests experiments es va poder detectar la dosi/dependència de l'efecte genotòxic de l'òxid d'estirè.
545

Temporomandibular joint X-ray computed tomography methodology and clinical applications /

Christiansen, Edwin L. January 1988 (has links)
Thesis (doctoral)--Karolinska Institutet, Stockholm, 1988. / Extra t.p. with thesis statement inserted. Includes bibliographical references.
546

Effect of doping ions and organic molecules on the precipitation and biological interactions of nanostructured calcium phosphates

Zhao, Zhitong 20 November 2015 (has links)
From a chemical and structural point of view, hydroxyapatite (HA) is a strong candidate in biomedical applications owing to its similarity to the inorganic components of bones and teeth. HA nanoparticles (NPs) as colloidal suspensions are becoming a popular tool in biomedical applications such as gene/drug delivery, bio-imaging etc. Although it is widely acknowledged that ionic substitutions on bulk HA substrates have a strong impact on their biological performance, little is known of their effect on NPs with potential use in gene transfection or drug delivery. In the third chapter carbonate (CO3) and magnesium (Mg) ions, which are the major substitutions in biological apatite, have been explored in the synthesis of ion-doped HA NPs under similar reaction conditions to allow comparison of results. CO3 and Mg ion were incorporated in the crystal lattice of HA and caused various changes mainly in the morphology and solubility of the different nanoparticles. In addition, the impact of ion doping on the interaction of HA NPs with cells was also evaluated under various cell culture conditions: 1) performing the cell culture study on citrate-dispersed NPs and on agglomerated NPs, 2) adding/excluding 10 % of foetal bovine serum (FBS) in the cell culture media and 3) using different types of cells, i.e. osteosarcoma MG-63 cells versus rat mesenchymal stem cells (rMSCs). The in vitro results indicated that Mg-doped HA NPs induced a profound impact on MG63 cells and, in the absence of citrate and FBS these nanoparticles were clearly cytotoxic. However, Mg-doped HA NPs did not alter cell viability in rMSCs under the same conditions. In the fourth chapter, Sr, Zn, Si and Fe(III) ions, which are minor ionic substitutions in biological apatite, were introduced to synthesize additional ion-doped HA NPs. Physicochemical characterization demonstrated that as-synthesized NPs were phase pure and doped ions had little influence on the morphology of NPs as in all cases they kept needle-like structure. Cytotoxicity studies performed using MG63 and rMSCs cells under the conditions of serum-containing and serum-free indicated that all NPs were non-cytotoxic if FBS was present. Interestingly, Zn-doped and Fe-doped HA NPs clearly stimulated MG63 cell proliferation in the absence of FBS. In addition to exploring the effect of ion-doped HA NPs on cell behaviour, it was also the interest of this thesis to investigate calcium phosphate (CaP) mineralization in the presence of organic molecules and also doping ions. In the fifth chapter of this thesis the effect of various organic molecules on CaP precipitation is provided. As shown by transmission electron microscopic studies (TEM) neuron-like CaP structures could be created using organic molecules of diverse nature such as non-ionic surfactant (Tween 80), anionic polymers (sodium polyacrylate) and cationic polymers (polydiallyldimethylammonium chloride). TEM studies through EELS, EFTEM and SAED proved that the neuron-like structures consisting of a dense core and thin filaments surrounding it had calcium, phosphorous and oxygen evenly distributed throughout the dense core as well as the filaments, and were amorphous in nature. Additionally, the co-effect of inorganic additives (i.e. Mg and Sr) together with organic molecules on CaP was also evaluated. It was proved that the addition of small amounts of ions had diverse impact on the stability of the neuron-like structures Mg clearly disrupting them but not Sr. All the findings with organic molecules provide much inspiration not only for the synthesis of more advanced CaP materials with novel structures and useful properties, but also for a better understanding of biomineralization process in nature. / Desde el punto de vista químico y estructural la hidroxiapatita (HA) se considera un gran candidato para aplicaciones biomédicas por su similitud con la fase mineral del hueso y los dientes. Aunque el efecto del dopaje se ha investigado con detalle en la fabricación de implantes viéndose que su presencia tiene un gran impacto en el comportamiento celular, poco se sabe de su efecto en nanopartículas para su uso en terapia génica y liberación de fármacos. En concreto, el tercer capítulo se centra en el dopaje de la apatita con iones carbonato (CO3) y magnesio (Mg) por ser éstas las sustituciones más importantes en la apatita biológica. Para ello todas las reacciones de síntesis se realizan bajo las mismas condiciones con la finalidad de poder comparar resultados. Los resultados muestran que ambas sustituciones acaban incorporando los iones dentro de la estructura del cristal causando diferentes impactos principalmente a nivel de morfología y solubilidad. Con respecto al impacto del dopaje en la caracterización celular, se llevaron a cabo diferentes ensayos: 1) utilizando suspensiones dispersadas con citrato o sin él, 2) en medio de cultivo con o sin 10 % v/v de suero fetal bovino y 3) utilizando dos tipos de células diferentes, células de osteosarcoma (MG63) y células de rata mesenquimales (rMSCs). Los resultados in vitro mostraron que las nanopartículas dopadas con Mg eran claramente citotóxicas a las células MG63 en ausencia de FBS. Sin embargo, las mismas NPs no alteraron la viabilidad celular en rMSCs bajo las mismas condiciones. El capítulo cuarto se centra en la síntesis y caracterización de NPs dopadas con iones Sr, Zn, Si y Fe(III), que representan sustituciones minoritarias en la apatita biológica. Su caracterización fisicoquímica mostró que todas las NPs eran puras con morfología acicular. Los estudios de citotoxicidad con células MG63 y rMSCs, con y sin FBS, mostraron viabilidad en presencia de FBS para todas las NPs. Además, para las NPs dopadas con Zn y Fe se observó un aumento notable en la proliferación celular para las MG63 cultivadas sin FBS. Además de explorar el efecto del dopaje de iones en NP de HA, otro campo de interés en esta tesis ha sido investigar la mineralización de fosfatos de calcio (CaP) en presencia de moléculas orgánicas y de diferentes iones. A través de estudios recientes en el grupo de investigación se ha visto que es posible formar fosfatos de calcio con estructura neuronal con la ayuda de simples moléculas orgánicas. En el quinto capítulo de esta tesis se estudia el efecto de varias moléculas orgánicas en la precipitación de CaP. Estudios por microscopia electrónica de transmisión (TEM) revelaron la presencia de estas estructuras neuronales formadas con la ayuda de moléculas orgánicas de diferente naturaleza: surfactante no iónicos (Tween 80), polímeros aniónicos (poliacrilato sódico) y políremos catiónicos (cloruro de polidialildimetilamonio). Varios estudios por TEM como son EELS, EFTEM y SAED permitieron establecer que las estructuras neuronales consistían de un núcleo denso del cual se extendía una red de filamentos, que en estas estructuras el calcio, fósforo y oxígeno estaba homogéneamente distribuido y que eran de naturaleza amorfa. Además se investigó el efecto simultáneo de añadir aditivos inorgánicos (iones Mg i Sr) junto con moléculas orgánicas. Se observó que la adición de pequeñas cantidades de iones afectaba la estabilidad de las estructuras neuronales. Con Mg las estructuras no eran estables pero sí con Sr. Estos estudios pueden ser fuente no sólo de inspiración en la síntesis de estructuras más avanzadas y con propiedades notablemente diferentes, sino que además proporcionan un mejor conocimiento de los procesos de biomineralización.
547

Desenvolvimento de phantoms para tomografia com feixe de prótons

Milhoretto, Edney 13 April 2012 (has links)
CNPq / Neste trabalho foram desenvolvidos phantoms para dois protótipos de tomografia com feixe de prótons (pCT). Um phantom foi desenvolvido para um protótipo de um mini tomógrafo utilizando um feixe de prótons de baixa energia, que está sendo desenvolvido na Universidade Tecnológica Federal do Paraná (UTFPR). O protótipo encontra-se em fase de teste no cíclotron CV-28 do Instituto de Engenharia Nuclear (IEN). Dois outros phantoms foram desenvolvidos para um protótipo de pCT no Centro Médico da Universidade de Loma Linda – CA, EUA (LLUMC). Os código GEANT4 e SRIM foram utilizados para simular todos os elementos que compõe os protótipos. Também foram feitos aprimoramentos no protótipo da UTFPR/IEN, entre eles um sistema de controle eletrônico do mecanismo, operado por um programa através de um computador, alteração no sistema de colimação para melhorar a resolução e a reconstrução de imagens obtidas por simulações. Foram realizados testes experimentais de perda de energia de prótons em polietileno de alta densidade (PEAD) no CV-28. Também foi feito experimentos de perda de energia de prótons em camadas de Poliestireno no LLUMC e comparação com dados simulados. Esses dois phantoms em PEAD foram construídos e testados no protótipo do LLUMC e um programa foi desenvolvido para a análise dos dados. / In this work phantoms were developed for two tomographic systems with proton beam (pCT). A phantom was developed for a mini scanner using a low energy proton beam, which is being developed at the Federal University of Technology - Parana (UTFPR) and tested at the CV-28 cyclotron at the Institute of Nuclear Engineering (IEN). Two additional phantoms were developed for the pCT prototype at Loma Linda University Medical Center – CA, USA (LLUMC). SRIM and Geant4 codes were used to simulate all the elements of the prototypes. Improvements were made in the UTFPR/IEN prototype such as electronic control system of mechanism, controlled by a computer program, upgrade in the collimation system to improve the resolution of reconstructed images obtained by simulations. Experimental energy loss tests were done with polyethylene protons of high density (PEAD) in CV-28. Experiments of energy loss in layers of polystyrene at the LLUMC were also done and compared with simulated data. Both phantoms were constructed and tested in the prototype of LLUMC and a program was developed for data analysis.
548

Procedimentos de ensaio de segurança e funcionalidade em radiologia diagnóstica /

Berns, Edileusa January 1998 (has links)
Dissertação (Mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. / Made available in DSpace on 2012-10-17T08:40:39Z (GMT). No. of bitstreams: 0Bitstream added on 2016-01-08T23:21:37Z : No. of bitstreams: 1 137920.pdf: 7451231 bytes, checksum: 0f1761540c3730c86243c3ef7e487d35 (MD5)
549

Avaliação do exame radiográfico convencional e digital e digital no diagnóstico da adaptação entre implantes dentários e protéticos

Duarte, Glauber Vieira January 2007 (has links)
Submitted by Suelen Reis (suziy.ellen@gmail.com) on 2013-04-23T17:44:03Z No. of bitstreams: 1 Dissertacao Glauber Duarte.pdf: 759281 bytes, checksum: 38271c0a48d32eb71858d76a5872d689 (MD5) / Approved for entry into archive by Rodrigo Meirelles(rodrigomei@ufba.br) on 2013-05-16T18:01:18Z (GMT) No. of bitstreams: 1 Dissertacao Glauber Duarte.pdf: 759281 bytes, checksum: 38271c0a48d32eb71858d76a5872d689 (MD5) / Made available in DSpace on 2013-05-16T18:01:18Z (GMT). No. of bitstreams: 1 Dissertacao Glauber Duarte.pdf: 759281 bytes, checksum: 38271c0a48d32eb71858d76a5872d689 (MD5) Previous issue date: 2007 / A Implantologia é uma das modalidades de reabilitação bucal, inclusive pela alta taxa de sucesso das próteses implanto-suportadas. No entanto, estão sujeitas a alguns problemas exclusivos, como o afrouxamento do parafuso e a fratura do parafuso de fixação. A adaptação marginal de um pilar protético sobre o implante é imprescindível para que muitas destas falhas não ocorram. Além disso, desadaptações e cavidades entre estes componentes podem favorecer o acúmulo de bactérias e causar reações inflamatórias nos tecidos periimplantares. O estudo da adaptação marginal entre estes componentes faz parte de uma linha de pesquisa, com o objetivo de estabelecer um método diagnóstico padronizado, eficaz e reprodutível de avaliação. O presente estudo propôs-se a verificar a validade do método radiográfico convencional e sistema digital Digora, quanto à capacidade diagnóstica da adaptação marginal de cinco pilares protéticos, em titânio Procera Alltitan®, com diferentes aberturas entre o implante e o pilar protético. Os pilares foram aparafusados em um implante, que foi posteriormente fixado a uma base metálica hexagonal, permitindo a padronização das tomadas radiográficas e da avaliação microscópica. Os pilares foram avaliados quanto a sua adaptação no implante, utilizando um microscópio óptico comparador (Mitutoyo®), utilizado como padrão-ouro do estudo. Foram utilizados matrizes de poliéster em tiras com o intuito de obter aberturas marginais padronizadas de 50µm, 100µm, 150µm e 200µm, considerando que cada tira possui uma espessura de 50µm. Em cada sistema foram realizadas 75 tomadas radiográficas (15 de cada grupo de abertura marginal), obtendo imagens com cinco tipos de adaptação (adaptado, 50µm, 100µm, 150µm e 200µm). Deste modo, foram avaliados 150 pontos proximais, em cada sistema radiográfico. Dois radiologistas avaliaram as imagens e para a análise estatística foi utilizada uma matriz de decisões para a realização dos testes diagnósticos de: sensibilidade, especificidade, acurácia, valor preditivo positivo e negativo e a medida estatística Kappa. Os resultados obtidos indicaram que os sistemas radiográficos, convencional e digital, possuem alta sensibilidade, especificidade, acurácia, valores preditivos e bom nível de concordância com o grupo-ouro, com uma discreta, mas não relevante, redução da eficácia diagnóstica do sistema digital. Observou-se que os sistemas radiográficos avaliados são excelentes ferramentas de diagnóstico quando aberturas marginais maiores que 50µm não são aceitáveis. Deve-se considerar que o sistema radiográfico digital Digora® possui grandes vantagens sobre o sistema convencional, como a redução da dose de radiação, a eliminação de erros humanos durante o processamento e a economia de tempo. Deste modo, o sistema Digora pode ser incluído como uma ferramenta de grande importância na reabilitação protética sobre implantes. / Salvador
550

Qualidade de imagem radiológica : calculando sensibilidade e especificidade em mamografias digitais diagnósticas do HCPA – auditoria interna

Mello, Juliana Mariano da Rocha Bandeira de January 2015 (has links)
OBJETIVOS: Avaliar a certeza de qualidade dos resultados mamográficos em uma instituição de referência para diagnóstico e tratamento do câncer de mama na Região Sul do Brasil, considerando as recomendações da quinta edição do BIRADS (“Breast Imaging Reporting and Data System”) para propósitos de auditoria. MATERIAL E MÉTODOS: Foi realizado um estudo de coorte observacional retrospectivo e transversal com 4911 pacientes que foram submetidas a pelo menos uma mamografia durante o ano de 2013 em um hospital público regional, ligado a uma universidade pública federal na Região Sul do Brasil. Essas pacientes foram acompanhadas até 31 de dezembro de 2014, para checar as taxas de desempenho dos resultados mamográficos na instituição em estudo, incluindo verdadeirospositivos (VP), verdadeiros-negativos (VN), falso-positivos (FP), falso-negativos (FN), valores preditivos positivos (VPP), sensibilidade e especificidade com um intervalo de confiança de 95%. RESULTADOS: O estudo demonstrou alta certeza de qualidade nos resultados das mamografias digitais diagnósticas, especialmente em relação à sensibilidade (90,21%) e especificidade (98,97%). O valor preditivo positivo (VPP) geral foi estimado em 65,3%. A taxa de interpretação anormal (ou reconvocação) foi de 12,26% e a razão de verossimilhança (“likelihood ratio”) das mamografias diagnósticas obtida foi 86,68%. CONCLUSÕES: Conclui-se que os resultados de mamografias digitais diagnósticas foram apropriados e similares aos valores pospostos pelo BIRADS. Além disso, o estudo proporcionou auto-reflexão e auto-avaliação da prática radiológica no serviço, o que é essencial para o melhoramento e processo de colaboração mais efetivo entre todos os profissionais envolvidos com o diagnóstico e tratamento do câncer de mama. Esses resultados podem incentivar outras instituições a atingirem altas taxas de qualidade de desempenho nos resultados mamográficos, apesar de possíveis limitações estruturais quando comparadas a instituições de países desenvolvidos. / OBJECTIVES: To evaluate the quality assurance of the mammography results in a reference institution for breast cancer diagnosis and treatment in southern Brazil, considering the BIRADS (Breast Imaging Reporting and Data System) 5th edition recommendations for auditing purposes. MATERIAL AND METHODS: We performed a retrospective cohort observational and cross-sectional study with 4911 patients who underwent at least one mammography throughout the year of 2013 in a regional public hospital, linked to a federal public university in southern Brazil. These patients were followed until 31st December, 2014 to check the performance rates of mammography results in our institution, including true-positives (TP), true-negatives (TN), false-positives (FP), false-negatives (FN), positive predictive values (PPV), sensitivity and specificity with a confidence interval of 95%. RESULTS: The study has showed high quality assurance on digital diagnostic mammographic results, especially regarding sensitivity (90,21%) and specificity (98,97%). The overall positive predictive value (PPV) was estimated in 65,3%. The abnormal interpretation rate (recall rate) was 12,26% and the likelihood ratio of diagnostic mammograms obtained was 86,68%. CONCLUSIONS: We concluded that our digital diagnostic mammography results were appropriate and similar to values proposed by the BIRADS. Also, the study provided self-reflection and insights on our radiological practice, which is essential to the improvement and more effective collaboration process between all the professionals involved with breast cancer diagnosis and treatment. These results may incentivize other institutions to achieve high quality performance rates in mammography results, despite possible infrastructure and facilities limitations when comparing to developed countries.

Page generated in 0.0504 seconds