• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 393
  • 140
  • 74
  • 72
  • 4
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 686
  • 277
  • 276
  • 276
  • 276
  • 212
  • 191
  • 190
  • 62
  • 50
  • 49
  • 48
  • 47
  • 47
  • 47
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
571

Desenvolvimento de objeto simulador antropomórfico de cabeça com dolomita e metilmetacrilato para dosimetria em tomografia computadorizada

Ximenes Filho, Raimundo Erivan Morais 19 February 2016 (has links)
Computed Tomography (CT) is a modality of radiodiagnostic that represents only 15% of the medical procedures performed in this field, nonetheless, this technique contributes with 50% of the collective dose. Procedures that delivers high doses, such as CT, need to be administered under a strict protocol of quality control (QC), because there will always be risks to the health of the patients when they are submitted to high dose exams. From this scenario, the necessity of evaluate the parameters of the X ray beam which the patient is rising; one of the main parameters to be monitored is the dose delivered by the CT exam. It is impossible to perform QC tests in a patient, that is why objects that simulates the attenuation profile of some part of the human body are used. In this specific research, the goal was the construction of a human head phantom. This phantom were built from easy access materials with the goal to be more financially advantageous to use it than its internationals competitors, hence it was spent only U$ 160.00 on its construction. International phantom prices can be more than U$ 4,600.00. Among the analyzed materials in this research, dolomite and polymethyl methacrylate (PMMA) were chose to manufacture the phantom, due its measurements of linear attenuation coefficients (m/) in different proportions, it was decided that dolomite and PMMA in a 1:1 proportion attenuates the X ray beam like the reference material (bone). Dosimetric studies were made in the phantom using an ionization chamber. Its results showed that the effective dose estimative in the dolomite phantom is (2.70 + 0.03) mSv and in the CTDI phantom is (3.67 + 0.04) mSv. Effective dose estimatives found in the literature for head computed tomography exams are in the range of 0.9 – 4.0 mSv. Effective dose measured with the phantom developed in this research are within this range. / A tomografia computadorizada (CT) é uma modalidade do radiodiagnóstico que representa aproximadamente 15% do total dos procedimentos médicos realizados nesta área, entretanto, esta técnica contribui com cerca de 50% da dose coletiva. Procedimentos que depositam altas doses, tais como a CT, devem passar por rigorosos testes de controle de qualidade (CQ), uma vez que sempre há riscos para a saúde do paciente quando ele é submetido a exames com doses elevadas. Daí surge a necessidade de avaliar os parâmetros do feixe de raios X aos quais o paciente está sendo submetido; um dos principais a ser monitorado é a dose a que se está expondo-o ao se realizar um exame CT. A realização dos testes de CQ em pacientes é inviável, por isso, são utilizados objetos simuladores que tentam replicar o perfil de atenuação de alguma parte do corpo humano. No caso específico desse trabalho, o objetivo foi a construção de um objeto simulador (ou phantom) da cabeça humana. Este phantom foi construído com materiais de fácil acesso para que ficasse mais vantajoso financeiramente quando comparado com seus concorrentes internacionais, uma vez que foram gastos apenas R$ 350,00 na sua confecção. Os objetos simuladores importados podem chegar a custar até mais de R$ 10.000,00. Dentre os materiais analisados neste trabalho, foram escolhidos, para serem usados na confecção do phantom, a dolomita e polímero de metilmetacrilato (PMMA). Tendo em vista os resultados das medidas de coeficientes de atenuação mássico (m/) desses materiais em diferentes proporções, foi definido que em uma proporção em massa de 1:1 entre a dolomita e a resina acrílica, o perfil de atenuação de raios X do objeto simulador se aproxima com o da referência (osso). Estudos dosimétricos foram feitos no objeto simulador usando uma câmara de ionização. Seus resultados mostraram que a estimativa de dose efetiva para o objeto simulador de dolomita é de (2,70 + 0,03) mSv e para o geométrico de acrílico é de (3,67 + 0,04) mSv. Os valores para dose efetiva encontrados na literatura sugerem que exames da cabeça de tomografia computadorizada estão em um intervalo de 0,9 – 4,0 mSv. As doses efetivas obtidas com o objeto simulador desenvolvido por esta pesquisa citadas anteriormente, encontram-se dentro desse intervalo.
572

Aplicação do recurso de subtração radiografica digital na avaliação da região perimplantar

Bittar-Cortez, Juliana Araujo 02 February 2005 (has links)
Orientador: Francisco Haiter Neto / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-14T19:27:31Z (GMT). No. of bitstreams: 1 Bittar-Cortez_JulianaAraujo_M.pdf: 3295326 bytes, checksum: 3905a9f6f1bc2ee984cad244a6df872b (MD5) Previous issue date: 2005 / Resumo: O exame radiográfico após a instalação de implantes endósseos é um importante meio auxiliar de diagnóstico para se avaliar as alterações no tecido ósseo adjacente, pois durante as fases de reparo e remodelação, no primeiro ano após a implantação ocorre uma redução do osso marginal. Foi proposto investigar o uso da subtração radiográfica digital na avaliação da região perimplantar em um estudo in vivo. Trinta e quatro pacientes foram monitorados através de radiografias periapicais convencionais padronizadas, no primeiro acompanhamento pósoperatório após a cirurgia para instalação de implantes endósseos e quatro meses após, antes da segunda fase cirúrgica, ao final do período de remodelação óssea. As radiografias foram digitalizadas e imagens de subtração radiográfica digital foram criadas por meio de um programa de computador denominado EMAGO. Os dois tipos de imagens, digitalizadas e subtração radiográfica digital, foram comparadas quantitativamente a partir de medidas de densidade óssea, obtidas por meio do histograma de uma área selecionada e por meio de medidas lineares da altura óssea presente avaliando também a reprodutibilidade interobservadores. Dentro das condições deste estudo, concluiu-se que a subtração radiográfica digital tem uma capacidade de diagnóstico semelhante à imagem digitalizada convencional na avaliação de densidade óssea, entretanto, medidas de altura óssea podem ter valores mais próximos do real utilizando imagens de subtração, mas essas medidas apresentam uma variabilidade inter-observadores / Abstract: Radiographic evaluation in connection with implant installation is an important means of diagnosing changes in bone tissue around the implant, where during the healing and the early remodeling phases, a slight reduction of the marginal bone height occurs in the first year after implant placement. The proposition for this research was to validate the use of the digital subtractionradiography in the perimplant region assessment in an in vivo study. Thirty four patients were monitored by standardized periapical conventional radiography in thefirst postoperative follow-up after surgery for implant placement and four months later, prior to the second-stage surgery at the end of the healing period. The radiographs were digitized and digital subtraction radiography was created by means of EMAGO software. The two types of images, digitized and digitalsubtraction radiography, were compared quantitatively by measuring bone density of a selected area by the histogram and by assessing bone height with linear measurements and also evaluating the reproducible inter-observers. Within the limits of this study, it was concluded that digital subtraction radiography has similar diagnostic performance to those of conventional digitized radiography in evaluating bone density however, bone height can be more precisely assessed with the subtraction images but the measurements has an inter-observers variability / Mestrado / Radiologia Odontologica / Mestre em Radiologia Odontológica
573

Radiografia panorâmica e tomografia cone beam: Análise de tumores dos maxilares / Panoramic radiography and cone beam CT: Analysis of tumors of the maxillary

Barros, Renata Quirino de Almeida 20 July 2011 (has links)
Made available in DSpace on 2015-09-25T12:18:24Z (GMT). No. of bitstreams: 1 Renata Quirino de Almeida Barros.pdf: 651574 bytes, checksum: 691f9ca6ac269e365c41d390ddf57550 (MD5) Previous issue date: 2011-07-20 / The diagnosis through image of neoplastic lesions that affect the maxillomandibular complex has been worthful for dentists in the elaboration of the surgical planning. This work aims to evaluate and correlationate the accuracy of panoramic radiography compared to the cone beam computed tomography, regarding the delineation of odontogenic and non-odontogenic tumors, diagnosed at the city of Campina Grande, Paraíba, Brazil, in the period between November 2009 and March 2011. There were 23 tumors diagnosed in various regions of the maxillomandibular complex, whose panoramic radiographies and computed tomographies were analyzed by 2 radiologists, in terms of the following radiographic aspects: radiolucency, presence or absence of mineralizations, definition of the lesions edges, expansion and breaking of bone cortical, as well as the relation to the anatomic structures and dental elements. The results were: 73,9% of patients with odontogenic tumors and 26,1% non-odontogenic, having histopathological standard for diagnosis, 65,2% of female patients and 34,8% of male patients, 56,5% of tumors located at the mandible, 34,8% at the maxilla and 8,7% at both arcs. It was observed the limitation of panoramic radiography in the analysis of the radiographic aspects. The cone beam tomography offered results more focused and statistically meaningful for the evaluation of bone destruction, as well as for the expansion of vestibular and palatine/lingual cortical. It was concluded that despite of panoramic radiography being the chosen examination to visualize lesions in maxilla, cone beam computed tomography provides better accuracy in terms of delineation, expansion and breaking of cortical bones, helping in the surgical planning and patient s follow up. / O diagnóstico por imagem das lesões tumorais que acometem o complexo maxilo-mandibular tem sido de grande valia para o cirurgião-dentista na elaboração de um planejamento cirúrgico. Este trabalho teve como objetivo avaliar e correlacionar a acurácia da radiografia panorâmica frente à tomografia computadorizada cone beam no delineamento dos tumores odontogênicos e não odontogênicos dos maxilares, diagnosticados no município de Campina Grande PB, no período de novembro de 2009 a março de 2011. Foram diagnosticados 23 tumores em várias regiões do complexo maxilo-mandibular, cujas radiografias panorâmicas e tomografias computadorizadas foram analisadas por 2 radiologistas, quanto aos seguintes aspectos imaginológicos: forma de radioluscência, presença ou não de mineralizações, definição das margens da lesão, expansão e rompimento de cortical óssea, bem como relação com estruturas anatômicas e dentes. Os resultados nos mostraram que 65,2% dos pacientes eram do sexo feminino e 34,8% do masculino, 56,5% dos tumores estavam localizados na mandíbula, 34,8% na maxila e 8,7% em ambos os arcos, 73,9% dos pacientes apresentaram tumores odontogênicos e 26,1% não odontogênicos, tendo como padrão de diagnóstico o histopatológico. Observou-se a limitação da radiografia panorâmica na análise dos aspectos radiográficos observados. A tomografia cone beam ofereceu resultados mais direcionados e estatisticamente significativos para avaliação do rompimento das corticais vestibular e palatina/lingual, bem como para a expansão óssea. Concluiu-se que apesar da radiografia panorâmica ser o exame de escolha para visualizar as lesões que acometem os maxilares, a tomografia computadorizada de feixe cônico proporcionou uma melhor acurácia no delineamento, expansão e rompimento das corticais ósseas, auxiliando no planejamento cirúrgico e na proservação do paciente.
574

Comparação da eficácia antibacteriana do álcool 70% (p/v) sobre superfície da câmara escura portátil com e sem limpeza prévia: um estudo experimental laboratorial / Comparison of the antibacterial efficacy of the alcohol 70% (w/v) over portable darkroom surfaces through rubbing, with and without previous cleaning processes: a laboratorial and experimental study

Maurício Uchikawa Graziano 09 August 2011 (has links)
No contexto da prevenção da infecção cruzada na radiologia odontológica, superfícies que entram em contato direto com as mãos dos profissionais, como as superfícies da câmara escura portátil, devem ser descontaminadas. A recomendação clássica da descontaminação com álcool 70% p/v após limpeza prévia, nem sempre é seguida justificada pela não praticidade, acrescida do tempo curto disponível entre um atendimento e outro, limitando-se à aplicação direta do álcool o que, a priori, contraria as Boas Práticas de Controle de Infecção. A presente investigação, de caráter experimental laboratorial, controlado, randomizado e unicegado, teve como objetivo avaliar comparativamente a eficácia desinfetante do álcool 70% (p/v) sob fricção, com e sem limpeza prévia nas superfícies de câmaras escuras portáteis como procedimento de limpeza/desinfecção concorrente em radiologia odontológica. Três grupos de estudo foram constituídos: Grupo controle: superfícies previamente contaminadas com desafio (micro-organismo teste Serratia marcescens ATCC 14756, acrescido de 10% de saliva humana), submetidas à limpeza clássica por meio de água e detergente sob fricção, e posterior enxágue e consecutivamente, desinfecção com aplicação do álcool 70% p/v. Grupo experimental: superfícies previamente contaminadas com desafio, à semelhança do grupo controle, submetidas à aplicação direta do álcool 70% p/v sob fricção, SEM limpeza prévia. Grupo controle positivo: superfícies contaminadas com desafio. O tamanho amostral para os grupos experimental e controle foi de 85 unidades. Os experimentos foram realizados no Laboratório de Ensaios Microbiológicos do Departamento de Enfermagem Médico-Cirúrgica da Escola de Enfermagem da Universidade de São Paulo. Após o procedimento de contaminação, desafio da área superior da câmara escura portátil e sua posterior secagem, no grupo experimental a superfície foi diretamente friccionada com álcool 70% (p/v) durante 30 segundos. No grupo controle, o mesmo procedimento foi realizado, após a limpeza prévia. Imediatamente, após a evaporação do álcool da superfície, foi realizada a coleta microbiológica por meio da fricção com swab. Em seguida, a ponta do swab foi quebrada e mergulhada em um tubo de ensaio esterilizado com 1 mL de SF e agitado em Votex® por 30 segundos, intermitente e todo o conteúdo do tubo de ensaio foi vertido no centro de uma placa de Petri e, sobre ele, derramados 15 a 20 mL do meio Trypticase Soy Agar à temperatura aproximada de 30ºC. As placas foram deixadas na posição invertida, em ambiente à temperatura aproximada de 22ºC por 72 horas, com leitura diária da recuperação das UFC da Serratia marcescens. O controle positivo foi colhido da mesma forma que o dos Grupos Controle e Experimental, porém sem a aplicação de métodos para descontaminação. As médias das UFC foram comparadas entre os grupos experimental e controle, por meio do teste estatístico t de Student. Os resultados permitiram concluir que o álcool 70% p/v, quando aplicado diretamente sobre a superfície contaminada com matéria orgânica sob fricção, é um desinfetante eficaz, comprovado pela redução de seis logaritmos da população microbiana intencionalmente desafiada nos experimentos, não diferindo da redução observada no grupo controle (p=0,440). Estes achados permitiram atestar a segurança desta prática na limpeza/desinfecção concorrente durante as práticas de radiologia odontológica. / Aiming to avoid cross infection in the context of dental radiology, surfaces that get in direct contact with the hands of the professionals involved in dental procedures are ought to be decontaminated, such as the portable darkroom surfaces. The classical recommendation for the alcohol 70% w/v decontamination (which requires previous cleaning process) is not always applied due to its lack of practicality in addition to the short amount of time between dental procedures; so the decontamination is restricted only to the application of alcohol contradicting then, a priori, the good Practices of Infection Control. This investigation, which was conducted following laboratorial and experimental character, controlled, randomized and blinded, has had as its aim: evaluating comparatively the disinfecting efficacy of rubbing the surfaces of portable darkrooms with 70% w/v alcohol, with and without previous cleaning processes, as an alternative procedure for cleaning/disinfection in dental radiology. Three study groups were established: Control Group: previously contaminated surfaces with the worst case contaminant (test microorganism Serratia marcescens ATCC 14756 added to 10% of human saliva) firstly, traditionally cleaned by rubbing with water and detergent, rinsed afterwards then decontaminated using alcohol 70% w/v; Experimental Group: previously contaminated surfaces with the worst case contaminant similarly to Control Groups sample, however submitted straight away to the decontamination by rubbing with alcohol 70% w/v, with NO previous cleaning processes; Positive control Group: surfaces contaminated with the worst case contaminant. The sampling for both, the experimental and control groups, was 85 units. The experiments were conducted at the Microbiology Laboratory of the Medical-Surgical Nursing Department of the University of Sao Paulos Nursing School. After the worst case contamination procedure of the portable darkrooms upper area and drying, at the experimental group: the surface was directly rubbed with alcohol 70% w/v for thirty seconds. At the control group, the same procedure was performed, however, with previous cleaning following the traditional processes. Immediately after the alcohols evaporation from the surface, a microbiological collection was performed by swab friction. Afterwards, the swabs tip was broken and put in a sterile test-tube with 1mL of sterile saline solution and shaken in Vortex® for thirty seconds, and all its content poured into a Petri dish. Fifteen to 20 mL of Trypticase Soy Agar at approximately 30ºC was poured over the Petri dish. The dishes were left inverted, in an acclimatized environment (approximately at 22ºC) for 72 hours, with daily assessment of the Serratia marcescens CFUs (Colony-forming unit) growths. The positive control was collected following the same procedure as the other groups (control and experimental), with no decontamination methods applied. The CFU levels were compared between the Control and Experimental groups, regarding the statistic test of the t test of Student. The results allowed concluding that the alcohol 70% w/v rubbing, when applied straight to the contaminated surface, is an efficient disinfection method, proved by the 6 logs reduction of the worst case bacterial population; no different from the reduction observed at the control group (p=0,440 test t of Student). These results allow attesting and ratifying the safety of this alternative cleaning/disinfection processes in the context of dental radiology.
575

Avaliação de doses em órgãos em procedimentos de tomografia computadorizada utilizando dosímetros TL e OSL / Organ doses evaluation for computed tomography procedures using TL and OSL dosimeters

Louise Maria Giansante Martins 07 July 2017 (has links)
Desde o desenvolvimento do primeiro equipamento de Tomografia Computadorizada (TC) no começo dos anos 1970, essa modalidade de diagnóstico por imagem passou por diversas melhorias. Produção de imagens de alta qualidade e exclusivamente digitais sem a superposição de estruturas anatômicas, exames com a duração de até cinco segundos e a capacidade de detectar patologias importantes sem a necessidade de cirurgias exploratórias são algumas das grandes vantagens obtidas quando essa técnica é utilizada. Como consequência, o papel dessa modalidade diagnóstica tem crescido amplamente ao redor do mundo. Nos Estados Unidos, por exemplo, 2,2 milhões de exames de TC foram realizados em 1980, apenas 10 anos após sua implementação. Esse número cresceu para 78,7 milhões no ano de 2015. Como resultado, a dose de radiação absorvida por pacientes devido ao uso dessa técnica tem se tornado uma preocupação entre radiologistas, pesquisadores e fabricantes, levando ao desenvolvimento de diferentes metodologias para estima-la. Câmaras de ionização, dosimetria termoluminescente (TL) e, mais recentemente, dosimetria luminescente opticamente estimulada (OSL), por exemplo, têm sido amplamente aplicados para se estimar dose em órgãos in vivo, em cadáveres e em objetos simuladores (phantoms). Outra abordagem extensivamente utilizada é a computacional, baseada em simulações Monte Carlo, que pode ser utilizada na comparação com resultados experimentais. Nesse trabalho, uma abordagem experimental utilizando TLDs e OSLDs em objetos simuladores adulto e pediátrico foi utilizada. Diversas análises foram realizadas com o objetivo de estabelecer o melhor caminho para conseguir os principais resultados alcançados e a metodologia desenvolvida foi eficiente para a finalidade proposta. As características dos OSLDs foram analisadas para verificar sua aplicabilidade no estudo de doses provenientes de procedimentos de TC. As respostas dos dosímetros demonstraram homogeneidade, linearidade com o kerma no ar incidente, reprodutibilidade, possibilidade de reutilização e dependência energética. Esses dosímetros foram utilizados em objetos simuladores adulto e pediátrico para o estudo de doses provenientes de protocolos clínicos de TC selecionados após uma análise de banco de dados de pacientes coletados do Instituto de Radiologia da Faculdade de Medicina da Universidade de São Paulo. As doses em órgãos medidas com os dosímetros foram comparadas com simulações Monte Carlo. Para órgãos contidos na região de exame, as diferenças entre doses medidas e simuladas estão no intervalo de ±20%. Esses resultados demonstraram, ainda, que o alinhamento e posicionamento incorretos do paciente antes do exame podem ocasionar um aumento maior do que 100% na dose de um órgão. / Since the development of the first Computed Tomography (CT) equipment in the early 1970s, this diagnostic imaging modality has gone through several improvements. Exclusively digital and high quality images production without superposition of anatomical structures, examinations as fast as five seconds, and the capability of diagnosing important pathologies with no need of exploratory surgeries are some of the great advantages when using this technique. As a consequence, the role of this diagnostic procedure has been widely increasing worldwide. In the US, for instance, 2.2 million CT exams were performed in 1980, only 10 years after its implementation. This number increased to 78.7 million in 2015. As a result, absorbed dose by patients due to this technique has become a concern among radiologists, researchers and manufacturers, leading to the development of different methodologies to evaluate it. Ionization chambers, thermoluminescence (TL) and, more recently, optically stimulated luminescence (OSL) dosimetry, for instance, have been widely applied in order to estimate in vivo organ doses, in post-mortem subjects and in phantoms. Another approach that has been extensively used are the Monte Carlo simulations, which can be applied in comparison with experimental results. An experimental approach to evaluate organ doses in pediatric and adult anthropomorphic phantoms by using TLDs and OSLDs was employed in the present study. Several analyses were performed in order to stablish the best way to achieve the main results in this investigation and the methodology proved to be efficient. The characteristics of the OSLDs were analyzed to verify their applicability for evaluating doses from CT procedures. The characterization included homogeneity, linearity with the incident air kerma, reproducibility, reusability and an energy-dependent response to distinct effective energies evaluation. These dosimeters were applied along with TLDs in an adult and a pediatric anthropomorphic phantoms to evaluate organ doses due to clinical CT protocols. These protocols were selected after an analysis of patient data collected from the Institute of Radiology of the School of Medicine of the University of São Paulo (Instituto de Radiologia da Faculdade de Medicina da Universidade de São Paulo). Organ doses measured with dosimeters were compared with Monte Carlo simulations. Differences between measured and simulated absorbed organ doses were within ±20%. Moreover, these results showed that a misalignment and incorrect positioning of the patient in the couch can increase an organ dose by more than 100%.
576

Vinculação de imagens para busca e visualização a partir de um sistema de informação em radiologia (RIS) / Bonding of images to search and visualization to inicial of radiology information system (RIS)

Edilson Carlos Caritá 12 March 2002 (has links)
Este trabalho apresenta o estudo e implementação de um sistema para vinculação e visualização de imagens de ressonância magnética nuclear e tomografia computadorizada a partir de um sistema de informação em radiologia (RIS), possibilitando a recuperação e disponibilização dos exames (laudos e imagens), através de rede \"ethernet\", para visualização a partir de uma interface desenvolvida para \"browser\". Os exames podem ser recuperados através do número de registro (RGHC) ou do nome do paciente. As imagens utilizadas no trabalho estão nos padrões DICOM 3.0 (Digital Imaging and Communications in Medicine) e JPEG (Joint Photographic Experts Group). Para a vinculação dos exames que possuem suas imagens em JPEG foi desenvolvida uma interface para inclusão das informações necessárias que garantem a consistência deste processo. Para os exames que possuem suas imagens em formato DICOM 3.0 as informações foram extraídas automaticamente dos cabeçalhos e armazenadas no banco de dados. O sistema possui uma interface amigável ao usuário, podendo ser rapidamente incorporada ao projeto de um PACS (Picture Archiving and Communication System). A implementação foi idealizada para servir ao Hospital das Clínicas da Faculdade de Medicina de Ribeirão Preto da Universidade de São Paulo (HCFMRP/USP), com base no seu sistema de informação em radiologia. Os resultados demonstram que o tempo de retorno das imagens é clinicamente satisfatório e considerado bom pela avaliação qualitativa dos médicos. / This work presents the study and implementation of a system aiming the indexing and visualization of the images of nuclear magnetic resonance and computerized tomography from a radiology information system (RIS), allowing the retrieval and availability of the exams (results and images), through an ethernet net for visualization beginning with an interface developed to a browser. The exams may be recovered either through their register number (RGHC) or the patient\'s name. The images employed in the work follow the DICOM 3.0 (Digital Imaging and Communications in Medicine) and JPEG (Joint Photographic Experts Group) patterns. For the indexing of the exams that present images in JPEG, an interface was developed to include the information required to guarantee the consistency of the process. For the exams presenting the DICOM 3.0 format, information was extracted automatically from the heading and filed in the database. The system has a friendly interface for the user, it may be rapidly incorporated to the project of an PACS (Picture Archiving and Communication System). The implementation was idealized to serve the Hospital das Clínicas da Faculdade de Medicina de Ribeirão Preto, of the Universidade de São Paulo (HCFMRP/USP), based on its radiology information system (RIS). The results demonstrated that the time of retrieval of the images is satisfactory and considered good by evaluation qualified of the doctors.
577

Avaliação morfológica e morfométrica da articulação coxofemoral do buldogue inglês / Morphological and morphometric evaluation of hip joint from English Bulldog

Bruno Ferrante 06 May 2016 (has links)
A displasia coxofemoral é a afecção ortopédica mais frequente na espécie canina e, pela estatística apresentada pela Orthopaedic Foundation for Animals o buldogue inglês é a raça com maior acometimento proporcionalmente. Entretanto carece em literatura dados sobre o desenvolvimento e morbidade desta doença na raça. O objetivo desse estudo foi avaliar a morfologia e morfometria da articulação coxofemoral de cães da raça buldogue inglês por meio de exame radiográfico e por tomografia computadorizada comparando-os com achados da avaliação ortopédica e cinética. A hipótese proposta é de que buldogues podem apresentar alterações radiográficas compatíveis com a displasia coxofemoral sem apresentar manifestações clínicas da doença. De cada articulação avaliada foram adquiridos dados por meio de exame ortopédico, avaliação cinética, radiográfica e por tomografia computadorizada. Foram feitas avaliação subjetiva das alterações morfológicas radiográficas e aferição do ângulo de Norberg, ângulo de inclinação do colo femoral e o escore de subluxação dorsolateral. Os dados obtidos foram correlacionados por meio dos coeficiêntes de Spearman. Trinta cães foram avaliados, 20 machos e 10 fêmeas. As médias de idade e peso dos participantes do estudo foram de 3,5 anos e 26,1 kg respectivamente. 76,6% dos animais apresentaram escore de condição corporal acima do considerado ideal e 63,3% viviam em ambiente de piso liso. Entretanto esses fatores de risco avaliados não apresentaram correlação com nenhuma alteração pesquisada. 63,3% dos cães apresentaram alterações nas articulações dos joelhos e 40% nas articulações coxofemorais pela avaliação ortopédica. Pela palpação da articulação coxofemoral foram observadas alterações em 50% dos animais, sendo a crepitação leve representando 86,6% das alterações, e crepitação de grau moderado e discreta manifestação de dor em 13,3%. A frequência de alterações morfológicas radiográficas observada foi de 98,3% para subluxação coxofemoral, 81,6% para o achatamento da cabeça do fêmur, 70% para presença de osteófitos ou entesófitos periarticulares e 61,1% para o arrasamento acetabular. A conformação radiográfica da articulação coxofemoral mais frequente foi de cabeça femoral com formato discretamente elíptico e discretamente subluxada, bordas acetabulares craniolateral arredondada e dorsal encurtada com discreta presença de osteófitos. A média das mensurações morfológicas obtidas no estudo foram abaixo dos valores considerado de normalidade, sendo de 94,94° para o ângulo de Norberg, 27,13% para o escore de subluxação dorsolateral e 128,53° para o ângulo de inclinação do colo femoral. A presença de osteófitos periarticulares obteve correlação estatística com presença de crepitação à palpação da coxofemoral, assim como o arrasamento acetabular com a presença de dor ao exame ortopédico. Entretanto as manifestações clínicas não coincidiram proporcionalmente às alterações observadas pelos métodos de diagnóstico por imagem. É questionado se a conformação muscular da raça pode contribuir para contrabalancear a instabilidade articular apresentada pelos métodos avaliados / Hip dysplasia is the most common orthopedic disorder in dogs, and the statistics presented by the Orthopedic Foundation for Animals English Bulldog is the race with most animals affected proportionately. However it lacks in literature data of the development and morbidity of this disease in the race. The aim of this study was to evaluate the morphology and morphometry of the hip joint of English Bulldogs through radiographic examination and computed tomography comparing them with findings from orthopedic and kinetic evaluation. The hypothesis proposed is that Bulldogs may have radiographic changes compatible with hip dysplasia without showing clinical symptoms of the disease. From each joint evaluated were acquired data through orthopedic examination, and kinetics, radiographic and computed tomography evaluations. They were made subjective evaluation of radiographic morphological changes and measuring the Norberg angle, femoral neck inclination angle and the dorsolateral subluxation score. The data were correlated by the Spearman\'s rank. Thirty dogs were evaluated, 20 males and 10 females. The mean age and weight of the study participants was 3.5 years and 26.1 kg respectively. 76.6% of the animals had a body condition score considered above ideal and 63.3% lived in flat floor environment. However, these risk factors evaluated were not correlated with any changes searched. 63.3% of dogs showed changes in knee joints and 40% in hip joints by the orthopedic evaluation. Abnormalities were observed in 50% of animals by palpation of the hip joint, the slight crackle representing 86.6% of the changes, and moderate crackle and mild degree manifestation of pain in 13.3%. The frequency of morphological radiographic changes observed was 98.3% for hip subluxation, 81.6% for the femoral head flattening, 70% for the presence of periarticular osteophytes or entesophytes and 61.1% for the acetabular razing. The most common radiographic conformation of the hip joint was femoral head slightly elliptical shape and discreetly subdisluxated, rounded craniolateral acetabular edge and shrtened dorsal edge with discreet presence of osteophytes. The average morphological measurements obtained in the study were below the values considered normal, being 94.94° for the angle of Norberg, 27.13% for dorsolateral subluxation score and 128.53° for inclination angle of the femoral neck. The presence of periarticular osteophytes have statistical correlation with the presence of ckakle on palpation of the hip joint, as well as the acetabular razing with the presence of painful on orthopedic examination. However the clinical manifestations were not proportionaly coincidence with the changes observed by the diagnostic imaging methods. It questioned whether the muscle conformation of the race can help to counteract the instability joint presented by the evaluated methods
578

Avaliação da contaminação microbiológica por meio do método convencional e Petrifilm™ em equipamentos e acessórios utilizados em radiografias digitais

Damasceno, Naiana Nolasco de Lima 29 May 2013 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-02-24T19:45:37Z No. of bitstreams: 1 naiananolascodelimadamasceno.pdf: 1654379 bytes, checksum: 096aa31bdb15da874cccff625dead4b3 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-03-06T19:31:13Z (GMT) No. of bitstreams: 1 naiananolascodelimadamasceno.pdf: 1654379 bytes, checksum: 096aa31bdb15da874cccff625dead4b3 (MD5) / Made available in DSpace on 2017-03-06T19:31:13Z (GMT). No. of bitstreams: 1 naiananolascodelimadamasceno.pdf: 1654379 bytes, checksum: 096aa31bdb15da874cccff625dead4b3 (MD5) Previous issue date: 2013-05-29 / Os objetivos deste estudo foram comparar o índice da contaminação microbiológica, antes e após os atendimentos clínicos, nas superfícies de equipamentos radiológicos digitais da Faculdade de Odontologia da Universidade Federal de Juiz de Fora; comparar a contaminação da clínica de Radiologia com as clínicas multidisciplinares e correlacionar dois métodos utilizados para coleta de microrganismos. As amostras foram coletadas das superfícies dos aparelhos de raios X periapical (cabeçote, braço articular, painel de controle e botão disparador), no sistema de radiografia digital (sensor) e no computador do sistema digital (teclado e mouse), utilizando dois métodos distintos: o método de esfregaço em superfície com auxílio de swab estéril (convencional) e o método de contato direto com a placa PetrifilmTM. As amostras foram semeadas em diferentes meios de cultura e após 48 horas de incubação, as colônias foram contadas. Colônias bacterianas isoladas presuntivamente pelo método convencional foram submetidas aos testes bioquímicos para identificação dos estafilococos, estreptococos e bacilos Gram negativos. Nenhum teste bioquímico foi realizado para bolores/leveduras. Para comparação entre as coletas realizadas antes e após os procedimentos clínicos foi utilizado o teste de Wilcoxon. Para comparação entre as duas clínicas foi utilizado o teste de Mann-Whitney. Foi calculado o coeficiente de Spearman para avaliar a correlação entre os métodos de coleta. Um total de 252 amostras foi coletado, dividido entre ambos os métodos. Não foram identificados estreptococos. Após os testes bioquímicos para estafilococos isolados pelo método convencional houve identificação de apenas um S. aureus (1,25%) isolado do botão disparador da clínica multidisciplinar, 16,25% foram identificados como S. saprophyticus e 82,50%, caracterizados como S. epidermidis. Entre os BGNs foram identificados: Chromobacterium violaceum, Pseudomonas pseudoalcaligenes, Ochrobactrum anthropi, Pseudomonas putida, Brevundimonas vesiculares. Não foi possível a recuperação das colônias coletados pelo PetrifilmTM. Pode-se concluir que a contagem de microrganismos foi maior antes dos procedimentos clínicos e na clínica multidisciplinar. Não houve correlação significativa entre os métodos de coleta testados. / The aims of this study were to compare the rate of microbiological contamination, before and after clinical treatments, in surfaces of digital radiography equipment of the Faculty of Dentistry of the Federal University of Juiz de Fora; to compare the contamination between the Radiology and multidisciplinary clinics; and correlate two methods used to collect microorganisms. Samples were collected from the surfaces of periapical X-ray machines (head, arm joints, control panel and shutter button), the digital radiography system (sensor) and the computer of digital system (keyboard and mouse), using two distinct methods: the method of smear surface with sterile swabs (conventional) and the method of direct contact with the plate PetrifilmTM. The samples were grown in different culture media and after 48 hours of incubation, colonies were counted. Bacterial colonies presumptively isolated by conventional method were subjected to biochemical tests for identification of Stafilococcus, Streptococcus and Gram-negative bacilli. No biochemical test was carried out for mold/yeast. For comparison between samples taken before and after clinical procedures we used the Wilcoxon test. For comparison between the two clinics was used the Mann-Whitney test. The Spearman coefficient was calculeted to assess the correlation between the methods of collection. A total of 252 samples were collected, divided between both methods. Streptococcus were not identified. After the biochemical tests for Stafilococcus isolates by the conventional method, only one S. aureus (1.25%) was isolated from the shutter button on the multidisciplinary clinic, 16.25% were identified as S. saprophyticus and 82.50% characterized as S. epidermidis. Among Gram-negative bacilli were identified: Chromobacterium violaceum, Pseudomonas pseudoalcaligenes, Ochrobactrum anthropi, Pseudomonas putida, Brevundimonas vesicular. Unable to recover the colonies collected by PetrifilmTM. It can be concluded that the microbial counts were higher before treatment in the multidisciplinary clinic. There was no significant correlation between the sampling methods tested.
579

Aplicação das unidades Hounsfield em imagens de tomografia computadorizada de feixe cônico / Application of Hounsfield units in cone beam computed tomography images

Nadaes, Mariana Rocha 06 February 2015 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2015-12-02T16:29:15Z No. of bitstreams: 1 marianarochanadaes.pdf: 1380064 bytes, checksum: f78140bd2137599acdd476c8c0e433a7 (MD5) / Rejected by Adriana Oliveira (adriana.oliveira@ufjf.edu.br), reason: Coreeção letras maiúsculas título on 2015-12-03T11:30:57Z (GMT) / Submitted by Renata Lopes (renatasil82@gmail.com) on 2015-12-03T11:36:28Z No. of bitstreams: 1 marianarochanadaes.pdf: 1380064 bytes, checksum: f78140bd2137599acdd476c8c0e433a7 (MD5) / Rejected by Adriana Oliveira (adriana.oliveira@ufjf.edu.br), reason: Título: somente primeira letra da primeira palavra em maiúsculo e nomes próprios também. Palavras-chave: primeira letra de cada palavra em maiúsculo. Acrescentar uma em cada linha (não precisa colocar ponto e nem vírgula no final) on 2015-12-03T11:59:32Z (GMT) / Submitted by Renata Lopes (renatasil82@gmail.com) on 2015-12-03T13:42:04Z No. of bitstreams: 1 marianarochanadaes.pdf: 1380064 bytes, checksum: f78140bd2137599acdd476c8c0e433a7 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2015-12-03T13:59:10Z (GMT) No. of bitstreams: 1 marianarochanadaes.pdf: 1380064 bytes, checksum: f78140bd2137599acdd476c8c0e433a7 (MD5) / Made available in DSpace on 2015-12-03T13:59:10Z (GMT). No. of bitstreams: 1 marianarochanadaes.pdf: 1380064 bytes, checksum: f78140bd2137599acdd476c8c0e433a7 (MD5) Previous issue date: 2015-02-06 / FAPEMIG - Fundação de Amparo à Pesquisa do Estado de Minas Gerais / Apesar das muitas indicações da tomografia computadorizada de feixe cônico (TCFC) na Odontologia, a avaliação da qualidade óssea, por meio das Unidades Hounsfield (HU), não apresenta um consenso sobre sua precisão e confiabilidade. O objetivo neste estudo foi avaliar, por meio de uma revisão sistemática da literatura, os principais resultados de pesquisas que compararam diversos materiais em exames de tomografia computadorizada multislice (TCMS) e TCFC, utilizando HU como unidade de medida. Para isso, foi realizada uma busca na base de dados Medline (PubMed) utilizando as palavras chaves “cone beam computed tomography”, “cone beam tomography”, “cbct”, “Hounsfield unit” e “Hounsfield”. A exclusão dos artigos foi realizada, inicialmente, por meio da leitura do título e resumo e, posteriormente, após a leitura do texto completo. Os dados da amostra selecionada (n=8) foram distribuídos em tabelas, possibilitando sua comparação. Os resultados obtidos em relação à aplicação de HU em TCFC foram divergentes, com alguns autores aplicando diretamente HU nesse exame, outros desenvolvendo fatores de correção para essa comparação e outros ainda, invalidando a utilização dessa unidade em exames de TCFC. Apenas um estudo concluiu que se pode aplicar diretamente HU em TCFC, sem prejuízo para avaliação das densidades dos tecidos. Assim, pode-se concluir que uma nova abordagem é necessária para o desenvolvimento de futuros trabalhos nessa linha e que a tentativa de aplicar HU em TCFC deveria ser abandonada. / Despite the many indications of cone beam computed tomography (CBCT) in dentistry, there is no consensus regarding the accuracy and reliability of bone quality assessment, through Hounsfield Units (HU). The aim of this study was to evaluate, through a systematic review of the literature, the main results of studies comparing various tissues in multislice CT (MSCT) and CBCT scans, using the HU as the unit of measurement. To this end, a search was conducted in the Medline (PubMed) database using the keywords "cone beam computed tomography", "cone beam tomography", "CBCT", "Hounsfield unit", and "Hounsfield". Articles were initially excluded by reading the title and abstract, and were later excluded after reading the full text. The data from the selected sample (n = 8) were tabulated and compared. The results obtained regarding the application of HU in CBCT were divergent, with some authors directly applying HU in CBCT, others developing correction factors for this comparison, and still others invalidating the use of this unit in CBCT. Only one study concluded that is possible to directly apply HU in CBCT, without damaging the evaluation of tissue densities. In this way, it’s possible to affirm that a new approach is necessary for the development of future work in this line and that the attempt to apply HU in CBCT should be abandoned.
580

Efeito da ação combinada de radiação gama e campo elétrico estático em células humanas. / Effect of the combined action of gamma radiation and static fields in human cells.

Michelle Mendes Moron 19 August 2008 (has links)
Neste trabalho estudamos o efeito da exposição de células humanas à radiação ionizante e em associação a campos elétricos exógenos estáticos. A linhagem T47D de células de carcinoma ductal mamário foi irradiada com gamas no intervalo 0 8 Gy. A viabilidade celular da linhagem T47D exposta à radiação gama e campo elétrico estático (CEE) de 1.250 V/cm foi cerca de 12% inferior à viabilidade observada apenas com irradiação. Quando aplicado isoladamente por 24 e 72 horas o CEE não induziu toxicidade. A imunofluorescência realizada na linhagem normal MRC5 (fibroblasto de pulmão humano normal) quantificou a expressão da histona -H2AX. A quantidade de histonas fosforiladas foi cerca de 40% maior após irradiação com 2 Gy mais CEE aplicado por 1h, indicando que o campo elétrico interferiu negativamente no processo de reparo das quebras duplas de DNA. A análise de citometria de fluxo (FACS) mostrou que em células T47D tratadas com 1 e 2 Gy por 24 horas o CEE também interferiu negativamente no processo de reparo do DNA, notadamente pelo maior acúmulo de células na fase S. / Our goal is the study in human cells of the effect resulting from the association of irradiation with exposure to exogenous static electric fields. The T47D cell line of breast cancer cells was irradiated with gammas in the 0 8 Gy doses range. The viability of this T47D cells exposed to both gamma radiation and 1.250 V/cm static electric field (SEF) was about 12% lower than when only irradiated. The sole exposure of the cells to SEF by 24 and 72 hours didnt induce toxicity. Immunofluorescence runs carried out in irradiated normal MRC5 cell line of human lung fibroblast have quantified the expression of the g-H2AX histone. The amount of phosphorylated histones was approximately 40% higher after irradiation with 2 Gy plus exposure to a SEF by 1 hour, showing that the electric field negatively interfered in the repairing process of the DNA double strand breaks. The flow cytometry analysis with FACS showed that in T47D cells treated with 1 and 2 Gy by 24 hours the SEF also negatively interfered in the DNA repairing process, as evidenced by the higher accumulation of cells in the S phase.

Page generated in 0.038 seconds