61

Análisis exergético y exergoeconómico avanzado para el diseño de un sistema de refrigeración por compresión a vapor de configuración paralela utilizando fluido CO2

Sevilla Silva, Daniella del Pilar 18 January 2021 (has links)
Los sistemas de refrigeración actuales se encuentran en un proceso de migración de fluidos refrigerantes contaminantes, a aquellos que utilicen refrigerantes medioambientalmente amigables y que contribuyan a la sostenibilidad del planeta. El refrigerante menos contaminante usado actualmente es el CO2, con un potencial de daño al medio ambiente y una contribución al calentamiento global nula. Sin embargo, a pesar de sus excelentes propiedades, el CO2 como tal no puede trabajar en todo el rango de temperaturas ambientales, sin ser necesario su paso a condiciones transcríticas (por encima del punto crítico). Debido a la condición transcrítica del ciclo de refrigeración convencional con CO2, se tiene que trabajar a altas presiones de compresión, lo que reduce el coeficiente de performance (COP, por sus siglas en inglés) en contraste con los valores de COP para los sistemas de refrigeración donde se usan otros refrigerantes más contaminantes. Esto limita la aplicabilidad de los sistemas de refrigeración con CO2 a nivel industrial. Para contrarrestar lo mencionado, se han estudiado diversas modificaciones al sistema de refrigeración convencional con CO2, entre las que destacan la inclusión de un intercambiador de calor interno, la compresión por etapas, el uso de ejectores, subenfriamiento adicional y la compresión paralela. La compresión paralela implica el uso de un compresor paralelo adicional, que incremente la presión del CO2 vaporizado que sale de la válvula de expansión, cuya capacidad refrigerante en los evaporadores es nula. De esta forma, el CO2 que ingresará al evaporador será sólo líquido (saturado, con calor latente para transferir) y este CO2 será el que ingrese después al compresor principal del sistema. A pesar de introducir un equipo adicional que consume energía (compresor paralelo), el COP de este sistema es considerablemente mayor al de un sistema convencional: mejora la transferencia de calor en el evaporador y reduce el consumo energético del compresor principal al trabajar con menor carga de CO2. De la literatura revisada, se ha definido a esta modificación como la de mayor potencial a futuro por sus mejoras notables en COP. En este trabajo, se ha analizado un sistema existente de refrigeración a dos niveles (media temperatura y baja temperatura) con compresión paralela usando CO2. El objetivo del análisis ha sido determinar el equipo menos eficiente del sistema y evaluar su optimización. Parte del análisis realizado implica el modelamiento matemático del sistema, un análisis exergético simple y avanzado y un análisis exergoeconómico. Se resalta el trabajo en un rango de temperaturas de -5 a 40 °C, no desarrollado hasta ahora en la literatura existente. Una de las primeras conclusiones obtenidas es la importancia del análisis exergético avanzado y sus ventajas sobre el simple. Un análisis exergético simple es válido únicamente para determinar dónde están las mayores pérdidas de exergía de un sistema de varios equipos. Si se requiere definir cuál equipo se debe optimizar para reducir la máxima exergía destruida posible del sistema, se requiere un análisis exergético avanzado, pues uno simple puede conllevar a resultados erróneos. Del trabajo realizado, se concluye que para un rango de temperaturas ambiente de -5°C a 40 °C, el equipo con potencial de mejoras en su diseño para reducir las irreversibilidades del sistema y por ende los costos del mismo, es el compresor de alta presión (CHP). Al mejorar el diseño del compresor de alta presión, no sólo se reduce la exergía destruida (total, endógena y evitable) del compresor de alta presión (CHP); sino además la exergía destruida (total, exógena y evitable) del enfriador de gas (GC), al verse impactadas sus condiciones de operación por el compresor de alta presión que se ubica aguas arriba del mismo en el sistema de refrigeración analizado. Se calculó una reducción máxima en la exergía destruida total para el compresor de alta presión (CHP) de hasta el 40% y una reducción máxima en la exergía destruida evitable de hasta el 45%. Para el enfriador de gas (GC), se obtuvo un máximo de reducción de exergía destruida total del 6% y en la exergía destruida evitable un máximo de reducción del 19%
62

Diseño de un sistema de refrigeración para conservar pescado, en una cámara frigorífica

Vejarano Valqui, Fredy Roger January 2016 (has links)
El documento digital no refiere un asesor / Publicación a texto completo no autorizada por el autor / La empresa Complejo Industrial Skavos S.A.C, requiere implementar un sistema de refrigeración para una cámara de conservación de pescado congelado que le permita conservar mayor cantidad de pescado, y usar el túnel de congelamiento solo para congelar el pescado. Por ello, el propósito de la presente monografía técnica es diseñar un sistema de refrigeración para conservar pescado, en una cámara frigorífica. Para su realización plantea los siguientes objetivos específicos: calcular la carga térmica que se requiere para la conservación de 12 TN pescado para el Complejo Industrial Skavos S. A. C., la cámara de conservación de pescado congelado deberá contar con una capacidad total de almacenamiento de 24 TN, seleccionar los componentes del sistema de refrigeración que cumplan con la carga térmica seleccionada, y seleccionar el refrigerante ecológico más adecuado para el sistema de refrigeración. / Trabajo de suficiencia profesional
63

Instalación y mantenimiento de un sistema dual de refrigeración

Olivas Melgarejo, Sergio Jesús January 2014 (has links)
Trata sobre un proyecto de instalación del sistema dual de refrigeración e implementación del Programa de Mantenimiento para una de las planta embotelladora de bebidas gaseosas de la empresa Corporación Lindley S. A, el proyecto se ejecuta en la Planta Callao y es implementado debido al crecimiento de la demanda de bebidas gaseosas además de cambiar el sistema de refrigeración el cual se efectúa con amoniaco, por tal motivo es necesario aumentar la capacidad de producción e instalar un nuevo sistema, aumentando la capacidad instalada y efectuando un programa de mantenimiento. Aborda las generalidades del proceso de refrigeración y su influencia en el proceso de embotellado de bebidas gaseosas, así mismo se detalla el montaje de los equipos del sistema de refrigeración y el programa de mantenimiento preventivo a los equipos adquiridos y a los existentes , aplicando un software de gestión denominado SAP (SISTEMA-APLICACIONES-PRODUCTOS) con referencia al módulo de mantenimiento PM. / Trabajo de suficiencia profesional
64

Comparative Analysis of Modern Energy Systems for Ice Rinks

Hemati, Pendar January 2023 (has links)
Ice rinks are highly energy-intensive commercial buildings with an average annual energy consumption of 1,000 MWh, most of it being used to cover the simultaneous heating and cooling demands. The aim of this thesis is to find the most energy efficient energy system for ice rinks by evaluating different system modifications and refrigerants. A comparative analysis of ammonia, CO2 and propane energy systems based on a representative ice rink for northern climates has been conducted. A traditional integrated ammonia ice rink consumes about 340 MWh per year to cover the thermal demands. The most promising energy efficiency measures for ammonia are using aqua ammonia as the secondary fluid and using an auxiliary heat pump to aid with covering heating demands. Thanks to these measures, energy savings of 12.9% can be achieved. A state-of-the-art trans-critical CO2 system using parallel compression consumes approximately 42.6% less energy than a conventional ammonia system, making it the most energy efficient solution for ice rinks with an SPF of 7.5. The good performance is largely linked to the possibility of operating CO2systems as direct systems, eliminating the need for indirect heat transfer and minimizing auxiliary equipment energy consumption. Propane, which has not been investigated as a refrigerant in ice rinks yet, was evaluated and compared against ammonia and CO2. A modern integrated propane system using parallel compression and an auxiliary heat pump is more energy efficient than a traditional ammonia system but requires more energy than modern ammonia or CO2 systems. Propane proved to be feasible and represents a potential alternative solution in ice rinks. Waste heat recovery is beneficial in every system and should be a key feature in ice rink energy systems. All systems use environmentally friendly refrigerants and their environmental impact is almost exclusively indirect and caused by electricity consumption. / Las pistas de hielo son edificios comerciales que consumen mucha energía, con un consumo medio anual de 1,000 MWh, la mayor parte de la cual se utiliza para cubrir las demandas simultáneas de calefacción y refrigeración. El objetivo de esta tesis es encontrar el sistema energético más eficiente para las pistas de hielo evaluando diferentes modificaciones del sistema y refrigerantes. Se ha realizado un análisis comparativo de los sistemas energéticos de amoníaco, CO2 y propano basado en una pista de hielo representativa de los climas nórdicos. Una pista de hielo de amoníaco integrada tradicional consume unos 340 MWh al año para cubrir las demandas térmicas. Las medidas de eficiencia energética más prometedoras para el amoníaco son el uso de aqua amoníaco como fluido secundario y la utilización de una bomba de calor auxiliar para ayudar a cubrir las demandas de calefacción. Gracias a estas medidas, se puede conseguir un ahorro energético del 12.9%. Un sistema de CO2 transcrítico de última generación que utiliza compresión paralela consume aproximadamente un 42.6% menos de energía que un sistema de amoníaco convencional, lo que lo convierte en la solución más eficiente desde el punto de vista energético para pistas de hielo con un SPF de 7.5. El buen rendimiento está ligado en gran medida a la posibilidad de operar los sistemas de CO2 como sistemas directos, eliminando la necesidad de transferencia indirecta de calor y minimizando el consumo de energía de los equipos auxiliares. El propano, que aún no se ha investigado como refrigerante en pistas de hielo, se evaluó y comparó con el amoníaco y el CO2. Un sistema moderno integrado de propano que utiliza compresión paralela y una bomba de calor auxiliar es más eficiente energéticamente que un sistema tradicional de amoníaco, pero requiere más energía que los sistemas modernos de amoníaco o CO2. El propano demostró ser viable y representa una posible solución alternativa en las pistas de hielo. La recuperación del calor residual es beneficiosa en todos los sistemas y debería ser una característica clave en los sistemas energéticos de las pistas de hielo. Todos los sistemas utilizan refrigerantes respetuosos con el medio ambiente y su impacto ambiental es casi exclusivamente indirecto y causado por el consumo de electricidad.
65

Diseño de sistema de enfriamiento de uvas de mesa con capacidad nominal de 510 kg/h

Pacheco Callirgos, Marco Augusto 09 April 2024 (has links)
En la actualidad, el sector agroindustrial en el país para la exportación de uva de mesa está creciendo; en un mercado competitivo nace la necesidad de mejorar la cadena de frío para la exportación de la uva de mesa y poder ofrecer un mejor producto de calidad. En ese sentido, se necesita fijar unas ciertas características al producto para su exportación mediante un adecuado enfriamiento. Con este propósito, se desarrolló el diseño y selección de componentes de un sistema de enfriamiento de uva de mesa con capacidad nominal de 510 kg/h. Se tomó como referencia las normas alimentaria CODEX STAN 255-2007 y NTP 0.11.12.2005 para cumplir con los requisitos finales de temperatura de la uva. Además, se consideró lo estipulado en los manuales de ASHRAE “Refrigeration 2018” y “Fundamentals 2017”; así como las directrices del Código Nacional de Electricidad y el uso de programas CAD. La propuesta es un sistema de enfriamiento rápido de tipo túnel estático de aire forzado con capacidad nominal de 510 kg/h, con una temperatura del aire del túnel de -15°C, la temperatura de evaporación es de -20°C y la de condensación es de 40°C. El tiempo de enfriamiento de 7,61 h, además de una capacidad de refrigeración de 31,43 kW y el uso de refrigerante R404a. Las dimensiones del sistema de enfriamiento son de 6 300 x 5 300 x 3 500 mm largo, ancho y alto respectivamente; y con costo total de USD 101 083,57.
66

Contribución al conocimiento del comportamiento térmico y la gestión térmica de los motores de combustión interna alternativos

Romero Piedrahita, Carlos Alberto 03 June 2009 (has links)
El trabajo desarrollado en la presente tesis está encaminado a estudiar los fenómenos de la transmisión de calor y balance térmico en los motores de combustión interna alternativos, tanto en el cilindro como en el sistema de refrigeración. El principal objetivo de la tesis ha sido la utilización y extensión de un programa computacional de predicción de temperaturas de paredes del motor y de dos programas comerciales de modelado de sistemas termohidráulicos para estudiar los flujos de calor dentro y fuera de la estructura del motor, para evaluar el balance térmico de los motores en estado estacionario y en condiciones transitorias y para modelar, simular y validar diseños nuevos de sistemas de refrigeración de motores para locomotoras. Para lograr este objetivo se han realizado varias tareas que se explican a lo largo de este documento, y que se sintetizan en una revisión de los modelos de transferencia de calor utilizados en los cálculos de flujos de calor en las diferentes condiciones de contorno presentes en los motores de combustión; la expansión de las capacidades de un modelo nodal para obtener de él los flujos de calor discriminados entre las partes metálicas del motor y los calores intercambiados entre los fluidos del sistema y las partes metálicas; el estudio experimental de la evolución de las temperaturas del motor durante el calentamiento bajo un ciclo de conducción con el fin de cuantificar el balance térmico en este modo de operación y proponer alternativas de bajo costo para mejorar ese tiempo de calentamiento; el modelado, simulación, validación y evaluación del impacto sobre el calentamiento, el consumo y las emisiones del motor, de alternativas propuestas en el diseño de los sistemas de refrigeración; y finalmente, la elaboración y aplicación de una metodología de prediseño, modelado y simulación de sistemas de refrigeración para aplicaciones especiales. / Romero Piedrahita, CA. (2009). Contribución al conocimiento del comportamiento térmico y la gestión térmica de los motores de combustión interna alternativos [Tesis doctoral]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/4923
67

Estudio teórico experimental del proceso de "flashing" de refrigerantes en válvulas de expansión

AIT BAHAJJI, MOHAMMED 21 March 2016 (has links)
[EN] In the regulation of a refrigeration system the expansion device have a fundamental role. The precise understanding of the way in which it works with different refrigerants is of crucial relevance in order to perform a precise design of these systems, as well as, to assist to its proper selection as a function of its capacity and the employed refrigerant. This thesis presents on the one hand the experimental characterization of the mass flow rate through an expansion valve with three different refrigerants: R22 (HCFC) as reference; R290 (propane) as a natural refrigerant, and R410A (HFC), currently one of the most common refrigerants, in a wide range of operating conditions and for different valve lifts. On the other hand, the work also includes the study of the modeling of the refrigerant flow through the expansion valve, and the development of a model based on the flashing process, with sufficient predictive ability to determine the mass flow rate circulating through the expansion valve according to the upstream fluid conditions and the opening valve. In order to determine accurately and precisely the minimum geometric area and the effective single-phase area of the expansion valve, it has been measured in the metrological center of UPV. In addition detailed hydraulic and pneumatic studies of the vale in two different test benches have been carried out. The analysis of experimental results obtained for the three refrigerants has shown that the mass flow rate through the expansion valve is strongly dependent on the upstream pressure and the degree of subcooling, but also slightly dependent on the downstream pressure. For the range of typical operation of heat pump and refrigeration systems, unlike some studies in literature have observed, the first-stage choking phenomena was not observed in our case. Instead, all the obtained results seem to be in the second-stage choking non-ideal flow. Obviously, the effect of the flow area on the mass flow is very important. The developed model of mass flow rate through expansion valves is basically derived from the Bernoulli equation for incompressible single-phase flow through orifices from assuming that the flow at vena contracta section is almost entirely liquid. The pressure at the vena contracta section is determined from the correlations obtained by Alamgir et al. [1981] and Abuaf et al. [1983] for water depressurization in "flashing" type expansions, in which a sudden depressurization occurs and subcooled liquid passes to metastable liquid and finally to two-phase flow. An adjustment coefficient, Ctwo-phase, was added to the model in order to take into account the effect of bubbles formation in the flow restriction, depending on the opening of the valve. This coefficient depends only on the flow area and it is close to the unit at high values of the flow area. The obtained results were found to be in good agreement with the measured data with approximately 95% of the measured data falling within a relative deviation of ±7%. / [ES] En la regulación del sistema de refrigeración como conjunto, el ajuste y estado del dispositivo de expansión tiene un papel fundamental, y el mejor conocimiento de su funcionamiento resulta de sumo interés para el correcto diseño del equipo, así como para asistir su correcta selección en función de la capacidad del mismo y del refrigerante empleado. Este trabajo de tesis doctoral presenta por un lado la caracterización experimental del flujo másico circulante a través de una válvula de expansión con distintos refrigerantes: el R22 (HCFC) como referencia, el R290 (propano) como refrigerante natural, y el R410A (HFC) como uno de los refrigerantes más habituales en la actualidad, en un amplio rango de condiciones de funcionamiento, para diferentes levantamientos de la válvula a estudio. Por otro lado, el trabajo incluye también el estudio del modelado del proceso de expansión a través de la válvula, y el desarrollo de un modelo basado en el proceso físico que se produce: "flashing", con capacidad predictiva suficiente para poder determinar el gasto másico circulante a través de la válvula de expansión en función de las condiciones del fluido aguas arriba y el área de paso de la misma. Para determinar con precisión y exactitud el área mínima geométrica y el área efectiva monofásica de la válvula de expansión se ha realizado medidas en el centro metrológico de la UPV, y también un estudio hidráulico y neumático detallado de la misma en sendos bancos de ensayo. El análisis de los resultados experimentales para los tres refrigerantes empleados ha mostrado que el gasto másico a través de la válvula de expansión es fuertemente dependiente de la presión aguas arriba y el grado de subenfriamiento, pero también ligeramente dependiente de la presión aguas abajo. Para el rango de funcionamiento típico de equipos de bomba de calor y sistemas de refrigeración, no se ha observado la primera etapa de flujo bloqueado que se mencionó en algunos estudios de la literatura, estando la totalidad de los resultados obtenidos claramente en la segunda etapa de flujo bloqueado no ideal. Obviamente, el efecto del área de paso sobre el gasto másico es muy determinante. El modelo de gasto másico a través de válvulas de expansión desarrollado se deriva básicamente de la ecuación de Bernoulli para flujo monofásico incompresible a través de orificios asumiendo que el flujo hasta la sección de vena contracta se encuentra prácticamente en su totalidad en estado líquido. La presión en la sección de vena contracta se ha determinado a partir de las correlaciones que obtuvieron Alamgir et al. [1981] y Abuaf et al. [1983] para la despresurización del agua en expansiones tipo "flashing", en los que se produce una despresurización súbita y el líquido subenfriado pasa a líquido metaestable y finalmente a flujo bifásico. Se ha añadido un coeficiente de ajuste, Cbifásico, en el modelo para tener en cuenta el efecto que puede tener la formación de burbujas en la restricción del flujo, en función del área de paso de flujo circulante a través de las válvulas. Este coeficiente sólo depende del área de paso y se acerca a la unidad a partir de un cierto tamaño del área de paso. Los resultados del modelo presentado en esta tesis doctoral son muy satisfactorios, llegando a predecir el 95% de los resultados con una desviación máxima del 7 %. / [CA] En la regulació del sistema de refrigeració com a conjunt, l'ajust i estat del dispositiu d'expansió té un paper fonamental i el millor coneixement del seu funcionament amb distints refrigerants resulta del màxim interés per al correcte disseny d'estos, així com per a assistir la seua correcta selecció en funció de la capacitat i del refrigerant empleat. Este treball de tesi doctoral presenta per un costat la caracterització experimental del flux màssic circulant a través d'una vàlvula d'expansió amb distints refrigerants: el R22 (HCFC) com a referència; el R290 (propà) com refrigerant natural, i el R410A (HFC) com un dels refrigerants més habituals en l'actualitat, en un ampli rang de condicions de funcionament, per a diferents alçaments de la vàlvula a estudi. D'altra banda, el treball inclou també l'estudi del modelatge del procés d'expansió a través de la vàlvula, i el desenrotllament d'un model basat en el procés físic que es produïx "flashing", amb capacitat predictiva suficient per a poder determinar el gasto màssic circulant a través de la vàlvula d'expansió en funció de les condicions del fluid aigües dalt i l'àrea de pas de la mateixa. Per a determinar amb precisió i exactitud l'àrea mínima geomètrica i l'àrea efectiva monofàsica de la vàlvula d'expansió s'han realitzat mesures en el centre metrológico de la UPV, i també un estudi hidràulic i pneumàtic detallat de la mateixa en sengles bancs d'assaig. L'anàlisi dels resultats experimentals per als tres refrigerants empleats ha mostrat que el fluxe màssic a través de la vàlvula d'expansió és fortament dependent de la pressió aigües dalt i el grau de subrefredament, però també lleugerament dependent de la pressió aigües aball. Per al rang de funcionament típic d'equips de bomba de calor i sistemes de refrigeració, no s'ha observat la primera etapa de flux bloquejat que es va mencionar en alguns estudis de la literatura, estant la totalitat dels resultats obtinguts clarament en la segona etapa de flux bloquejat no ideal. Òbviament, l'efecte de l'àrea de pas sobre el gasto màssic és molt determinant. El model de fluxe màssic a través de vàlvules d'expansió desenvolupat es deriva bàsicament de l'equació de Bernoulli per a flux monofàsic incompressible a través d'orificis a partir d'assumir que el flux fins a la secció de vena contracta es troba pràcticament en la seua totalitat en estat líquid. La pressió en la secció de vena contracta s'ha determinat a partir de les correlacions que van obtindre Alamgir t'al. [1981] i Abuaf t'al. [1983] per a la despresurització del aigua en expansions del típus "flashing", en eles que es produeix una despresurització súbita i el líquid subrefredad passa a líquid metaestable i finalment a fluxe bifásic. S'ha afegit un coeficient d'ajust, Cbifásico, en el model per a tindre en compte l'efecte que pot tindre la formació de bambolles en la restricció del flux, en funció de l'àrea de pas de flux circulant a través de les vàlvules. Este coeficient només depén de l'àrea de pas i s'acosta a la unitat a partir d'una certa grandària de l'àrea de pas. Els resultats del model presentat en aquesta tesi doctoral reprodueixen el 95% dels resultats en una desviacio máxima del 7%. / Ait Bahajji, M. (2016). Estudio teórico experimental del proceso de "flashing" de refrigerantes en válvulas de expansión [Tesis doctoral]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/61980
68

Calidad y deterioro de platos "sous vide" preparados a base de carne y pescado almacenados en refrigeración

Díaz Molins, Pedro 30 April 2004 (has links)
En la presente Tesis Doctoral se estudió la capacidad de conservación y la calidad sensorial de diversos platos preparados a base de carne o pescado cocinados mediante la tecnología sous vide y conservados en refrigeración. El objetivo fue estudiar el deterioro y determinar la vida comercial con el fin de introducir mejoras tecnológicas. Se determinaron diversos parámetros microbiológicos (enterobacterias totales, aerobios y anaerobios psicrófilos, bacterias ácido lácticas y mohos y levaduras), físico-químicos (pH, aw, acidez, textura instrumental y color CIELab) y sensoriales (análisis descriptivo cuantitativo del aspecto, olor, olor, sabor y textura). Los resultados obtenidos indican que los tiempos y temperaturas recomendados para cocinar la carne y/o el pescado sous vide aseguraron una correcta pasteurización. No se detectaron cambios apreciables de humedad, acidez, color o textura. Sólo el análisis sensorial permitió evaluar el deterioro de la carne y/o pescado sous vide durante su almacenamiento. La tecnología sous vide proporcionó platos refrigerados a base de carne y/o pescado con una alta aceptación y una vida comercial adecuada para su distribución en sistemas de catering. / The present PhD thesis analyses the preserving capacity and the sensory quality of different meat-or-fish-based dishes which are cooked by using the sous vide method and recreating the conditions of catering industry.The aim was to study the spoilage and to determine the shelf-life of these products to introduce technological improvements. For this purpose, several parameters were established: microbiological (aerobic and anaerobic psychrotrophs, lactic acid bacteria, Enterobacteriaceae, mould and yeasts), physical-chemical (pH, aw, acidity, instrumental texture and colour CIELab) and sensory (QDA of the appearance, colour, odour, flavour and texture). The results indicated that the periods of time and temperatures which are recommended to cook sous vide meat or fish guaranteed a correct pasteurization which prevented the proliferation, at 2 ºC, of Enterobacteriaceae and altering microorganisms. Only the sensory analysis permitted the evaluation of the spoilage of the sous vide cooked meat or fish during their storage. All this would leave a considerable safety margin in the cooking process so that the sensory quality could be adjusted. Besides, no noticeable variations of humidity, acidity, colour or texture were detected by the physical-chemical techniques, which were employed.
69

Eliminación del Biofouling en intercambiadores de calor-condensadores que minimicen el impacto ambiental en el medio marino

Río Calonge, Belén 28 September 1999 (has links)
La presente tesis doctoral tiene por objeto tratar de eliminar el fenómeno no deseable de formación de biofouling en diferentes superficies tubulares de intercambiadores de calor, mediante tratamientos físicos y químicos, intentando minimizar el impacto ambiental creado en los efluentes de las instalaciones industriales.El equipo experimental está compuesto por una planta piloto de intercambiadores de calor condensadores dotada de ocho tubos que funcionan como sistemas independientes, donde se controlan los parámetros de presión, temperatura y caudal, que define indirectamente el biofouling depositado en el interior de dichos tubos a través de los valores de resistencia friccional al flujo y resistencia a la transferencia de calor.También ha sido diseñado y construido otra planta piloto o monitor "MCMDID" (monitor combinado de medición directa e indirecta del biofouling) donde se mide en continuo el espesor del biofouling adherido a la superficie de un tubo del mismo material que los ensayados en la planta descrita anteriormente.
70

Combined Energy Systems Applied to Productive Sectors: The Case of Dairy Farms in Central Bolivia / Sistemas Combinados de Energía Aplicados a Sectores Productivos: El Caso de las Granjas Lecheras en Bolivia Central

Villarroel-Schneider, Johnny January 2019 (has links)
Most energy solutions in developing countries focus primarily on solving domestic energy demands of their growing populations without due consideration of sustainable development. On the other hand, in most of these countries, a segment of energy users that has not received enough attention from governments and institutions regarding appropriate energy solutions is the productive sector. This sector is mainly composed by small and medium-sized industries and ventures that greatly contribute to the countries’ economy, as in the case of Bolivia. However, the low investment capacity, the lack of knowledge, training and insufficient support from local and national governments do not allow these solutions to arrive as expected. Although many of these sectors have the potential to apply energy solutions utilizing alternative energy sources, as the waste generated by the activity, this work has not materialized. This is the case of the dairy farmers in central Bolivia, who do not have an adequate management of farm waste. This problem contributes negatively to the contamination of the local and global environment.  This study explores solutions of combined energy systems applied to the dairy sector of Bolivia. The two cases under investigation consider the utilization of waste from farms to produce biogas, which drives the proposed systems. The first solution focuses on a polygeneration system featuring either an internal combustion engine or internally fired microturbine for the simultaneous provision of biogas for cooking, electricity, refrigeration, and fertilizer. The second system involves trigeneration i.e. absorption chiller integrated to an externally fired microturbine for supplying electricity, refrigeration and hot water. Analysis methods include determination of levelized cost of services, payback period, primary energy rates and energy saving rates.  The techno-economic assessment for the polygeneration system shows that the costs of the supplied services are still attractive when compared to subsidized prices of fossil fuel-based services in the market if the investment capital of this system is partially subsidized. The biogas cost from the system is lower than the cost of conventional gas used for cooking. The use of the internal combustion engine results in a lower electricity cost than using the microturbine. The refrigeration cost is slightly higher than conventional refrigeration for both cases. A sensitivity analysis shows that the cost for feedstock (cow dung) can be increased while maintaining an attractive price of biogas, and that subsidies on investment capital cause a reduction in the services costs. In the case of energy performance evaluation of the trigeneration system it was found to be more efficient in terms of energy utilization than conventional fossil fuel-based solutions, and this leads to energy savings.  Finally, it is shown that combined energy systems applied to the Bolivian dairy sector are competitive in terms of their economic feasibility and energy performance. / De flesta energilösningar i utvecklingsländer fokuserar på att lösa inhemska energibehov för sina växande populationer utan att ta hänsyn till hållbar utveckling. Å andra sidan är ett segment av energianvändare den produktiva sektorn, som inte fått tillräckligt med uppmärksamhet från regeringar och institutioner när det gäller lämpliga energilösningar. Denna sektor består huvudsakligen av små och medelstora industrier och företag som i hög grad bidrar till ländernas ekonomi, vilket är fallet med Bolivia. Låg investeringskapacitet, brist på kunskap, utbildning och otillräckligt stöd från lokala och nationella regeringar tillåter dock inte att dessa lösningar kommer fram som förväntat. Även om många av dessa sektorer har potential att tillämpa energilösningar som använder alternativa energikällor, som det avfall som genereras av verksamheten, har detta inte exploaterats i nämnvärd grad. Detta gäller bland annat mjölkbönderna i centrala Bolivia, som inte har en adekvat hantering av jordbruksavfal, vilket bidrar negativt till föroreningar av den lokala och globala miljön. Denna studie undersöker lösningar med kombinerade energisystem för mjölkhantering i Bolivia. De två fall som undersöks gäller användningen av avfall från gårdar för att producera biogas, som driver de föreslagna systemen. Den första lösningen fokuserar på ett polygenerationssystem som innehåller antingen en förbränningsmotor eller mikroturbin med klassisk intern förbränning. Systemet möjliggör samtidig försörjning av biogas för matlagning och elgenerering, bl.a. för kylning samt ger gödningsmedel som restprodukt. Det andra systemet innefattar tri-gereration, dvs en absorptionskylare integrerad med en externt driven mikroturbin för att leverera el, kylning och varmt vatten. Analysmetoder innefattar bestämning av driftkostnader för de olika energitjänsterna, återbetalningsperiod, förbrukad primärenergi och relativ energibesparing. En teknisk-ekonomisk analys av polygenerationssystemet visar att kostnaderna för de tillhandahållna tjänsterna är attraktiva i förhållande till de subventionerade priserna på tjänster på marknaden om subventioner tillämpas på investeringskapitalet. Kostnaden för biogas från systemet är lägre än kostnaden för konventionell gas som används för matlagning. Användning av en förbränningsmotor resulterar i en lägre elkostnad än att använda en mikroturbin. Kylkostnaden är något högre än med konventionell kylning för båda fallen. En känslighetsanalys visar att kostnaden för råvaror (kogödsel) kan tillåtas öka, samtidigt som ett attraktivt biogaspris bibehålls, och att subventioner på investeringskapital leder till en minskning av kostnaderna för energitjänsterna. När det gäller utvärdering av energiprestanda för tri-gererationssystemet visade sig det vara mer effektivt när det gäller energianvändning än konventionella lösningar baserade på fossila bränslen, vilket leder till energibesparingar. Slutligen visas att kombinerade energisystem som tillämpas på mjölkhanteringssektorn är konkurrenskraftiga när det gäller den ekonomiska genomförbarheten och energiprestanda.