• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 255
  • 49
  • 29
  • 26
  • 20
  • 19
  • 16
  • 16
  • 5
  • 4
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 529
  • 92
  • 70
  • 70
  • 67
  • 60
  • 56
  • 54
  • 52
  • 51
  • 51
  • 51
  • 47
  • 45
  • 42
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
451

MEMS TUNABLE SI-BASED EVANESCENT-MODE CAVITY FILTERS: DESIGN, OPTIMIZATION AND IMPLEMENTATION

Zhengan Yang (5930441) 16 August 2019 (has links)
<div>The allocated frequency bands for the incoming fifth generation (5G) wireless communication technologies spread broadly from sub 6 GHz to K and potentially W bands. The evolution of the future generations toward higher frequency bands will continue and presents significant challenges in terms of excessive system complexity, production and maintenance costs. Reconfigurable radio architecture with frequency-tunable components is one of the most feasible and cost-effective solutions to meet such challenges. Among these technologies, evanescent-mode (EVA) cavity tunable resonator have demonstrated many of the needed features such as wide tunability, low loss and high linearity. Such a technology typically employs a movable membrane that controls the resonant frequency of a post-loaded cavity. </div><div><br></div><div>The first part of this work focuses on advancing such technology into the mm-wave frequency bands and beyond. Manufacturing tolerance and tuner performance are the two main limiting factors addressed here. This work develops a cost-effective micro-fabrication and package assembly flow which addresses the manufacturing related limitations. On the other hand, introducing micro-corrugated diaphragms and gold-vanadium co-sputtered thin film deposition technology, significantly reduces (4 times) the tuning voltage and enhances tuning stability (7 times). We demonstrate a tunable two-pole band-pass filter (BPF) prototype as the first EVA cavity tunable filter operating in the K-Ka band. </div><div><br></div><div>The second part of this work extensively discusses an optimal RF design flow based on the developed manufacturing technology. It considers all technology constrains and allows the actualization of a high Q transfer function with minimum bandwidth variation within an octave tuning range. Moreover, a new fully passive input/output feeding mechanism that facilitates impedance matching over the entire tuning range is presented. The devised RF methodology is validated through the design and testing of a two-resonator BPF. Measurements demonstrate a tuning range between 20-40 GHz, relative bandwidth of 1.9%-4.7%, and impedance matching over the entire tuning range which is upto 2 times better than previously reported state-of-the-art MEMS tunable filters of this type.</div><div><br></div><div>The third part of this work further advances the technology by proposing the first MEMS-based low-power bi-directional EVA tuning approach that employs both the main bias circuitry as well as a new corrective biasing technique that counteracts viscoelastic memory effects. The two key enabling technologies are extensively discussed: a) a new metal-oxide-metal (MOM) sealed cavity that maintains high quality without requiring complicated metal bonding; and b) a new electrostatic bi-directional MEMS tuner that implements the needed frequency tuning without lowering the resonator quality factor. </div><div><br></div><div>Furthermore, we explore important design and fabrication trade-offs regarding sensitivity to non-ideal effects (residual stress, fabrication imperfections). Measurement of the new prototype bi-directional design, prove that this technology readily corrects residual post-bias displacement of 0.1 um that shifts the frequency by over 1 GHz with less than 2.5 V. It takes over 100 seconds to recover this error in the uni-directional case. This correction does not adversely affect the filter performance.</div>
452

A flexible coil array for high resolution magnetic resonance imaging at 7 Tesla / Réseau flexible d'antennes miniatures pour l'imagerie par résonance magnétique haute résolution à 7 Tesla

Kriegl, Roberta 17 December 2014 (has links)
L’imagerie par résonance magnétique (IRM) est un outil d’investigation majeur donnant accès de manière non invasive à des nombreuses informations quantitatives et fonctionnelles. La qualité des images obtenues (rapport-signal-sur-bruit, RSB) est cependant limitée dans certaines applications nécessitant des résolutions spatiales et/ou temporelles poussées. Afin d’améliorer la sensibilité de détection des équipements d’IRM, diverses orientations peuvent être suivies telles qu’augmenter l’intensité du champ magnétique des imageurs, améliorer les performances des systèmes de détection radiofréquence (RF), ou encore développer des séquences d’acquisition et des techniques de reconstruction d’images plus efficaces. La thématique globale dans laquelle s’inscrit cette thèse concerne le développement des systèmes de détection RF à haute sensibilité pour l’IRM à haut champ chez l’homme. En particulier, des antennes auto-résonantes basées sur le principe des lignes de transmission sont utilisées parce qu’elles peuvent être réalisée sur substrat souple. Cette adaptabilité géométrique du résonateur permet d’ajuster précisément sa forme aux spécificités morphologiques de la zone anatomique observée, et ainsi d’augmenter le RSB. La première visée technologique de ce projet concerne le développement, de la conception jusqu’à la mise en œuvre dans un appareil 7 T corps entier, d’un système de détection RF flexible à haute sensibilité, utilisant des antennes miniatures associées en réseau. L’utilisation d’un réseau d’antennes miniatures permet d’obtenir des images sur un champ de vue élargi tout en conservant la haute sensibilité inhérente à chaque antenne miniature. De plus, la technologie de l’imagerie parallèle devient accessible, ce qui permet d’accélérer l’acquisition des images. De surcroît, un nouveau schéma de résonateur de ligne transmission avec un degré de liberté supplémentaire est introduit, ce qui permet de réaliser de grands résonateurs multi-tours pour l’IRM à haut champ. Cette thèse décrit le développement, la mise en œuvre et l’évaluation des nouveaux systèmes de détection RF au moyen de simulations analytiques et numériques, et des études expérimentales. / Magnetic resonance imaging (MRI), among other imaging techniques, has become a major backbone of modern medical diagnostics. MRI enables the non-invasive combined, identification of anatomical structures, functional and chemical properties, especially in soft tissues. Nonetheless, applications requiring very high spatial and/or temporal resolution are often limited by the available signal-to-noise ratio (SNR) in MR experiments. Since first clinical applications, image quality in MRI has been constantly improved by applying one or several of the following strategies: increasing the static magnetic field strength, improvement of the radiofrequency (RF) detection system, development of specialized acquisition sequences and optimization of image reconstruction techniques. This work is concerned with the development of highly sensitive RF detection systems for biomedical ultra-high field MRI. In particular, auto-resonant RF coils based on transmission line technology are investigated. These resonators may be fabricated on flexible substrate which enables form-fitting of the RF detector to the target anatomy, leading to a significant SNR gain. The main objective of this work is the development of a flexible RF coil array for high-resolution MRI on a human whole-body 7 T MR scanner. With coil arrays, the intrinsically high SNR of small surface coils may be exploited for an extended field of view. Further, parallel imaging techniques are accessible with RF array technology, allowing acceleration of the image acquisition. Secondly, in this PhD project a novel design for transmission line resonators is developed, that brings an additional degree of freedom in geometric design and enables the fabrication of large multi-turn resonators for high field MR applications. This thesis describes the development, successful implementation and evaluation of novel, mechanically flexible RF devices by analytical and 3D electromagnetic simulations, in bench measurements and in MRI experiments.
453

Détection non-destructive pour l’interférométrie atomique et Condensation de Bose-Einstein dans une cavité optique de haute finesse / Nondestructive detection for atom interferometry and Bose-Einstein condensation in a high finesse optical cavity

Vanderbruggen, Thomas 13 April 2012 (has links)
Ce mémoire de thèse étudie diverses méthodes d'amélioration des interféromètres atomiques. Dans la première partie du manuscrit, nous analysons comment une détection non-destructive, au sens où elle préserve la cohérence entre les états internes de l'ensemble atomique, permet d'améliorer la sensibilité des interféromètres. Nous montrons tout d'abord, grâce à une étude théorique, que la projection du vecteur d'onde engendrée par la mesure permet de préparer des états comprimés de spin. Nous présentons ensuite la mise en œuvre de cette méthode à l'aide d'une détection reposant sur la spectroscopie par modulation de fréquence. Finalement, nous exposons quelques premières applications de cette détection non-destructive, plus précisément nous présentons la réalisation du rétroaction quantique qui protège l'état atomique contre la décohérence induite par un basculement du spin collectif, nous montrons aussi comment réaliser une boucle à verrouillage de phase où les atomes servent de référence de phase. Dans la seconde partie du manuscrit, nous présentons la réalisation tout-optique d'un condensat de Bose-Einstein dans une cavité de haute finesse, exploitant les technologies développées pour les télécommunications optiques. Nous commençons par une analyse du résonateur et des méthodes d'asservissement, nous introduisons notamment une méthode d'asservissement originale exploitant la modulation serrodyne. Enfin, nous montrons comment un condensat est obtenu par évaporation dans le mode optique de la cavité. / In this thesis, we study several methods to improve atom interferometers. In the first part of the manuscript, we analyze how a nondestructive detection, that preserves the coherence between the internal degrees of freedom in an atomic ensemble, can be used to increase the sensitivity of interferometers. We first theoretically show how the projection of the wave-function induced by the measurement prepares spin-squeezed states. We then present the implementation of this method with a detection based on the frequency modulation spectroscopy. Finally, some first applications are described, more explicitly we show how to implement a quantum feedback that preserve the atomic state against the decoherence induced by a random collective flip, we also introduce a phase-locked loop where the atomic sample is used as the phase reference. In the second part of the manuscript, we present the all-optical realization of a Bose-Einstein condensate in a high-finesse cavity using a laser system based on standard telecoms technologies. We first describe the resonator and the frequency lock of the laser on the resonance, in particular, we introduce a new stabilization method based of the serrodyne modulation. Finally, we show how the condensate is obtained from the evaporation in the cavity mode.
454

Étude des concepts de filtrage robuste aux méconnaissances de modèles et aux pertes de mesures. Application aux systèmes de navigation / Study of filtering strategies robust to model ignorance and measurement losses. Application to GPS/INS navigation systems

Sircoulomb, Vincent 02 December 2008 (has links)
La résolution d'un problème d'estimation de l'état d'un système nécessite de disposer d'un modèle régissant l'évolution des variables d'état et de mesurer de manière directe ou indirecte l'ensemble ou une partie de ces variables d'état. Les travaux exposés dans ce mémoire de thèse portent sur la problématique d'estimation en présence de méconnaissances de modèle et de pertes de capteurs. La première partie de ce travail constitue la synthèse d'un dispositif d'estimation d'état pour systèmes non linéaires. Cela consiste à sélectionner un estimateur d'état et convenablement le régler, puis à concevoir algorithmiquement, à partir d'un critère introduit pour la circonstance, une redondance matérielle visant à compenser la perte de certains capteurs. La seconde partie de ce travail porte sur la conception, à l'aide de la variance d'Allan, d'un sous-modèle permettant de compenser les incertitudes d'un modèle d'état, ce sous-modèle étant utilisable par un filtre de Kalman. Ce travail a été exploité pour tenir compte de dérives gyroscopiques dans le cadre d'une navigation inertielle hybridée avec des mesures GPS par un filtre de Kalman contraint. Les résultats obtenus, issus d'expériences sur deux trajectoires d'avion, ont montré un comportement sain et robuste de l'approche proposée / To solve the problem of estimating the state of a system, it is necessary to have at one's disposal a model governing the dynamic of the state variables and to measure directly or indirectly all or a part of these variables. The work presented in this thesis deals with the estimation issue in the presence of model uncertainties and sensor losses. The first part of this work represents the synthesis of a state estimation device for nonlinear systems. It consists in selecting a state estimator and properly tuning it. Then, thanks to a criterion introduced for the occasion, it consists in algorithmically designing a hardware redundancy aiming at compensating for some sensor losses. The second part of this work deals with the conception of a sub-model compensating for some model uncertainties. This sub-model, designed by using the Allan variance, is usable by a Kalman filter. This work has been used to take into account some gyroscopical drifts in a GPS-INS integrated navigation based on a constrained Kalman filter. The results obtained, coming from experiments on two plane trajectories, showed a safe and robust behaviour of the proposed method
455

Transfert énergétique irréversible grâce à un résonateur acoustique à comportement non-linéaire / Irreversible energy transfer using an acoustic resonator with a nonlinear behavior

Alamo Vargas, Valentin 07 September 2018 (has links)
Dans un contexte d’amélioration des dispositifs pour la réduction de bruit, l’étude sur le transfert d’énergie irréversible en utilisant des résonateurs purement acoustiques à comportement non linéaire a été réalisée. Les résonateurs acoustiques classiques en régime linéaire agissent comme un Amortisseur de Masse Accordée (TMD, en anglais) et ils sont efficaces pour une gamme de fréquence très étroite. Cependant, lorsqu’ils sont soumis à des excitations très fortes (régime non-linéaire) ils peuvent devenir efficaces pour une plus large gamme de fréquences si des termes non linéaires peuvent être activés. Dans un premier temps, une étude sur ce comportement non-linéaire d’un résonateur d’Helmholtz modifié a été réalisée expérimentalement. Ensuite, l’équation dynamique gouvernante de tels résonateurs ont été développées en prenant en compte les non-linéarités de la force de rappel et d’amortissement. Une approximation de la solution analytique de l’équation gouvernante du résonateur acoustique a été déterminée en utilisant les méthodes des échelles multiples du temps et de transformation du temps non régulière. Dans un deuxième temps, une étude du couplage entre un mode acoustique en basses fréquences et un résonateur (celui étudié précédemment) à comportement non-linéaire a été réalisée. Pour ce faire, des mesures expérimentales avec un montage du système couplé ont permis de vérifier l’atténuation acoustique produite par le résonateur en régime forcé et libre. Une modélisation analytique du couplage a permis d’identifier l’expression de la variété invariante lente, ce qui a permis d’étudier les possibles points d’équilibre et points singuliers du système. Les modèles analytiques développés ont également été vérifiés par des simulations numériques. / Nowadays, there is a need of new types of technologies for sound reduction because of the growing of different industries. In this context, we have studied the targeted energy transfer using a purely acoustic resonator. These acoustic resonators act, in the linear regime, as a Tuned Masse Damper (TMD) and they are efficient for a narrow frequency band. But, when they are excited with high forces, in the nonlinear regime, they are efficient for a wider frequency band if the nonlinear terms are activated. First, an experimental study about the nonlinear behavior of a modified Helmholtz Resonator was done. Then, the governing equation of such resonators were developed considering the nonlinearities in the restitution force and damping. An approximation of the analytical solution of the governing equation of the acoustical resonator is derived using the multiples scales of time method and the non-smooth time transformation method. In a second part, a study about the coupling between an acoustic mode in low frequencies and a resonator (the one studied in the previous part) with a nonlinear behavior is done. In order to do this, experimental measurements of the coupled system to confirm acoustic attenuation by the resonator in forced and free regime were done. Then, an analytical modelling of the coupled system allowed to derive the expression of the Slow Invariant Manifold (SIM), in order to identify the possible equilibrium points and singular points of the system. Derived analytical models were verified by numerical simulations.
456

Optical frequency references based on hyperfine transitions in molecular iodine

Döringshoff, Klaus 14 May 2018 (has links)
Diese Arbeit beschäftigt sich mit der Entwicklung und Untersuchung von optischen Absolutfrequenzreferenzen basierend auf rovibronischen Übergängen in molekularen Jod. Dabei werden Methoden der Doppler-freien Sättigungsspektroskopie angewendet, um einzelne Übergänge der Hyperfeinstruktur mit Linienbreiten unterhalb von 1 MHz im B-X System von molekularem Iod bei 532 nm, der zweiten harmonischen des Nd:YAG-Laser, aufzulösen. Elektronische Regelungstechniken ermöglichen eine präzise Stabilisierung der optischen Frequenz auf die Linienmitte der Übergänge mit einer Auflösung von Teilen in 10^5. Mit dem Ziel einer weltraumtauglichen Absolutfrequenzreferenz für zukünftige Weltraummissionen, wurden zwei Spektroskopiemodule konzipiert und in quasi-monolithischen Glaskeramik-Aufbauten, als sogenanntes elegant breadboard model und engineering model, realisiert. Diese Jodfrequenzreferenzen wurden im Detail in Bezug auf ihre Frequenzstabilität und Reproduzierbarkeit untersucht und Letzteres wurde für die angestrebte Weltraumqualifizierung ersten Umwelttests, sowohl vibrations- als auch thermischen Belastungstests, unterzogen. Für die Untersuchung der Frequenzstabilität dieser Jodreferenzen wurde ein auf einen optischen Resonator hoher Güte stabilisiertes Lasersystem für direkte Frequenzvergleiche bei 1064 nm realisiert. Die Analyse der Frequenzstabilität der Jod Referenzen zeigt eine Frequenzstabilität von 6x10^−15 bei 1 s, und weniger als 2x10^−15 bei 100 s Integrationszeit, was der bis heute besten veröffentlichten Frequenzstabilität entspricht die mit Jod Referenzen erreicht wurde. Mit der erreichten Frequenzstabilität ermöglichen diese Absolutfrequenzreferenzen präzise Lasersysteme für zukünftige Weltraummissionen wie z.B. zur Detektion von Gravitationswellen, zur Vermessung des Gravitationsfelds der Erde oder für Präzisionstest fundamentaler Theorien der Physik. / This thesis deals with the development and investigation of optical absolute frequency references based on rovibronic transitions in molecular iodine. Doppler-free saturation spectroscopy methods are employed to resolve individual transitions of the hyperfine structure with linewidths below 1 MHz in the B-X system of molecular iodine at 532 nm with the second harmonic of Nd:YAG lasers. Electronic feedback control systems are employed for laser frequency stabilization to the line center of the optical transitions with a line splitting of 10^5. With the goal of a space qualified optical absolute frequency reference for future laser-interferometric space missions, two spectroscopy setups were designed and realized in quasi-monolithic, glass-ceramic setups as so called elegant bread board model and engineering model. These iodine references were characterized in detail with respect to their frequency stability and reproducibility and the engineering model was subject to environmental tests, including vibrations and thermal cycling to verify its applicability in future space missions. For the investigation of the frequency instability of these iodine references, a frequency stabilized laser system was realized based on a temperature controlled high Finesse ULE cavity for direct frequency comparisons at 1064 nm. Analysis of the frequency stability of the iodine references revealed exceptionally low fractional frequency instability of 6x10^−15 at 1 s, averaging down to less than 2×10^−15 at 100 s integration time, constituting the best reported stability achieved with iodine references to date. With the demonstrated performance, these absolute frequency references enable precision laser systems required for future space missions that are dedicated to, e.g., the detection of gravitational waves, mapping of the Earth’s gravitational field or precision test of fundamental physics.
457

Development of an Electromagnetic Glottal Waveform Sensor for Applications in High Acoustic Noise Environments

Pelteku, Altin E. 14 January 2004 (has links)
The challenges of measuring speech signals in the presence of a strong background noise cannot be easily addressed with traditional acoustic technology. A recent solution to the problem considers combining acoustic sensor measurements with real-time, non-acoustic detection of an aspect of the speech production process. While significant advancements have been made in that area using low-power radar-based techniques, drawbacks inherent to the operation of such sensors are yet to be surmounted. Therefore, one imperative scientific objective is to devise new, non-invasive non-acoustic sensor topologies that offer improvements regarding sensitivity, robustness, and acoustic bandwidth. This project investigates a novel design that directly senses the glottal flow waveform by measuring variations in the electromagnetic properties of neck tissues during voiced segments of speech. The approach is to explore two distinct sensor configurations, namely the“six-element" and the“parallel-plate" resonator. The research focuses on the modeling aspect of the biological load and the resonator prototypes using multi-transmission line (MTL) and finite element (FE) simulation tools. Finally, bench tests performed with both prototypes on phantom loads as well as human subjects are presented.
458

Développement d'un traitement acoustique basses-fréquences à base de résonateurs d'Helmholtz intégrés à membrane électroactive / Low frequency acoustic treatment based on integrated helmoltz resonators with electroactive membrane

Abbad, Ahmed 22 February 2018 (has links)
Ce projet de doctorat consiste en la proposition d'une solution technologique d'un résonateur de Helmholtz adaptatif à volume variable, permettant ainsi de s'affranchir du caractère mono-fréquentiel des résonateurs de Helmholtz passifs. Le réglage de volume s'effectue grâce à l'utilisation d'une membrane en polymère électroactif (EAP), permettant ainsi d'accorder les résonances du résonateur de Helmholtz. Le comportement mécanique de ces matériaux est modifié lorsqu'ils sont stimulés par un champ électrique. Des améliorations significatives en perte par transmission acoustique sont obtenues en basses fréquences par deux effets: la variation de raideur de la membrane et l'augmentation de volume due à la déformation de la membrane. Des études numériques, analytiques et expérimentales sont réalisées pour déterminer le potentiel des concepts proposés. Enfin, une structure périodique contenant 9 résonateurs adaptatifs à membranes électroactives est étudiée en champs diffus permettant d'évaluer les performances acoustiques du concept distribué. / This main goal of the project consists in proposing a technological solution of an adaptive Helmholtz resonator with variable volume, which allows to overcome the mono-frequency character of passive Helmholtz resonators. The volume control is achieved by the use of an electroactive polymer membrane (EAP), allowing the resonances of the Helmholtz resonator to be tuned. The mechanical behavior of these materials changes when they are stimulated by an electric field. Significant improvements in acoustic transmission loss are obtained at low frequencies by two effects: the variation of stiffness of the membrane and the increase of volume due to the deformation of the membrane. Numerical, analytical and experimental studies are carried out to determine the potential of the proposed concepts. Finally, a periodic structure containing 9 adaptive resonators with electroactive membranes is studied in diffuse fields to evaluate the acoustic performances of the distributed concept.
459

Etude et réalisation de filtres matriochkas pour des applications spatiales / Conception and fabrication of matriochka filters for spatial applications

Hallet, Christophe 26 October 2018 (has links)
Le résonateur matriochka est conçu à partir de résonateurs coaxiaux ré-entrants créant ainsi des sauts d’impédances (SIR). La thèse développe alors des innovations théoriques sur la technologie matriochka en proposant des modèles analytiques précis sur le comportement fréquentiel et du facteur de qualité du résonateur. Les modélisations mettent en relief l’existence de degrés de liberté au sein du résonateur matriochka induisant une flexibilité du rapport de forme du résonateur. Les degrés de liberté créent ainsi une multitude de configurations du résonateur matriochka pour une fréquence fondamentale et un facteur de qualité donnés. Par conséquent, une optimisation en volume est réalisée pour concevoir deux filtres en bande L et C afin de minimiser leur encombrement. Une étude de la tenue en puissance dans le vide est également effectuée pour le filtre en bande L. Une méthode conjointe d’optimisation de la tenue en puissance et de minimisation en volume est alors proposée pour ce filtre. Ainsi, les modélisations et les optimisations sont employées afin de concevoir et de fabriquer deux filtres hyperfréquences. Le premier est un filtre de transmission en bande L conçu pour l’application de navigation Galileo qui propose une alternative d’encombrement et une tenue en puissance dans le vide élevée. Enfin, le second est un filtre de réception en bande C conçu, fabriqué et mesuré pour l’application de télémesure qui propose de meilleures performances en réjection et un volume réduit par rapport à l’existant. Finalement, la technologie matriochka est une alternative de résonateur par rapport à l’état de l’art en proposant, selon les configurations, un rejet élevé des harmoniques et un volume réduit pour une fréquence fondamentale et un facteur de qualité donnés. / The matriochka resonator is based on reentrant coaxial Stepped Impedance Resonator (SIR). So, the thesis develops theoretical innovations on the matriochka technology offering accurate analytical models on the frequency and the quality factor behaviors of the resonator. The models prove the existence of degrees of freedom within the matriochka resonator which allows to get different form factors of the resonator. The degrees of freedom create many configurations of the matriochka resonator for a fundamental frequency and a quality factor. Consequently, a volume optimization is realized to design a L-band filter and a C-band filter. A multipactor study is also carried out for the L-band filter. So, a joint optimization method of the multipactor and the volume minimization is proposed for this filter. Thus, the models and optimisations are used in the order to to design and fabricate the microwave filters. The first one is a transmission L-band filter for the navigation application Galileo which offers a volume alternative and a high power in the vaccum. Then, the second one is a reception C-band filter for the telemetry application which offers wide spurious free-performance and a low volume compared to the state of the art. Finally, for a frequency and a quality factor and depending on the configurations, the matriochka technology offers an alternative of the resonator volume, and it offers a wide spurious free- performance and a low volume compared to the state of the art.
460

Etude du procédé de fabrication et de fonctionnalisation en vue de la réalisation d'un microdispositif vibrant pour de la détection spécifique en biologie / Study of the manufacturing process and functionalization in order to achieve a vibrating micro device for specific detection in Biology

Azzouz, Mériam 28 September 2012 (has links)
L’étude proposée est une étude préliminaire en vue d’utiliser des microrésonateurs en silicium fonctionnalisé en vue de la détection électromécanique d’espèces biologiques présentes à l’état de trace. Deux aspects ont été principalement étudiés : la capture ultra-sensible mais aussi la capture ultra-spécifique d’espèces biologiques comme des marqueurs pour la maladie d’Alzheimer. Elle a été effectuée dans le cadre d’une collaboration entre le département MINASYS (Micro et Nano-Système) de l’Institut d’Electronique Fondamental (IEF) et le Laboratoire Protéines et Nanotechnologies en Sciences Séparatives de la Faculté de Pharmacie de Châtenay-Malabry.Il s’est ainsi s’agit de développer un micro-résonateur en silicium intégrant des canaux enterrés permettant la circulation d’un fluide biologique à l’intérieur de la poutre et non à l’extérieur comme ils le sont plus couramment, et ce, dans le but de limiter au maximum l’amortissement du résonateur. En ce qui concerne les aspects en biologie, nous nous sommes plus particulièrement interessé à la détection d’un bio-marqueur de la maladie d’Alzheimer, le peptide amyloïde Aβ1-42. Jusqu’à présent, le dépistage de la maladie nécessite une concentration suffisamment importante de bio-marqueurs et le recours à une ponction du liquide céphalorachidien après l’apparition des symptômes de la maladie est donc nécessaire. Le microsystème présenté ici permettra de nous approcher d’un système capable de détecter des traces de biomarqueurs présentes dans le sang ou l’urine par exemple. Ainsi, dans un premier temps, nous avons mis au point un mode de détection précoce du peptide Aβ1-42 couplant un canal micro-fluidique et la microscopie à fluorescence. La surface des canaux en silicium doit être fonctionnalisée afin de permettre le greffage spécifique des antigènes. Pour cela, nous avons mis au point une technique s’appuyant sur la reconnaissance spécifique anticorps-antigène, celle-ci nécessitant une étape préalable de fonctionnalisation chimique de surface.Le manuscrit présenté ici s’articule en quatre parties principales. Dans un premier temps, une étude bibliographique permet de faire l’état de l’art sur le principe de fonctionnement de différents types bio-capteurs couramment utilisés et leurs performances. Une seconde partie décrit la fonctionnalisation de surface du silicium et plus spécifiquement de la réaction de silanisation en phase liquide réalisée sur des surfaces planes et dans des canaux fluidique. Nous abordons ensuite le domaine de la reconnaissance spécifique d’entités biologiques et détaillons les étapes de greffage des protéines réalisées sur les surfaces ainsi que la conception d’immuno-sandwich entreprise dans des canaux fluidiques. Enfin la dernière partie du manuscrit rassemble des différents résultats préliminaires obtenus en vue de l’élaboration du micro-capteur de type poutre résonante à canaux enterrés. / This study is a preliminary study to use a fonctionnalized microsensor based on electromechanical detection of biological species present at trace levels. Two aspects were involved in this work: capture high-sensitivity but also the capture of ultra-specific biological species as markers for Alzheimer's disease. It was conducted as part of collaboration between the department MINASYS (Micro and Nanobio and Microsystems) of the Institute of Fundamental Electronics (IEF) and the Laboratory Proteins and Nanotechnologies in Separative Sciences, at the Faculty of Pharmacy of Chatenay-Malabry.The sensor includes a micro-resonator, placed in vaccum, incorporating silicon buried channels for the circulation of a biological fluid and not outside as they are more commonly, and in order to minimize the damping of the resonator. As regards the biological aspects, we primily focus on the detection of a biomarker of Alzheimer's disease, amyloidal peptide Aβ1-42. Until now, screening requires the use of a puncture and cerebrospinal fluid after onset of symptoms, therefore a sufficiently high concentration of biomarkers is required. Initially, we developed a method of early detection of Aβ1-42 peptide coupling a microfluidic system and fluorescence microscopy. Therefore, the micro-resonator that are present here allow to detect these biomarkers that are present at very low concentrations in other biological fluids in the first stage of the disease, for example, in the blood or urine. Thus, in a first step, we have developed a method of early detection of Aβ1-42 peptide coupling channel microfluidic and fluorescence microscopy. The surface of the channels in silicon must be functionalized to allow the grafting of specific antigens. For this, we developed a technique based on the specific antibody-antigen recognition, the latter requires a preliminary step of chemical functionalization of surfaces.This manuscript consists of four main parts. Initially, we present a literature review of the state of the art on the principle of operation of various types commonly used bio-sensors and the performance obtained. A second chapter describes the functionalization of silicon area and more specifically of the silanization reaction in liquid phase performed on flat surfaces and in fluidic channels. In the following chapter, we discuss the field of specific recognition of biological entities and detail the steps of grafting performed on protein surfaces and design immunoassay sandwich in fluidic channels. The last chapter of the manuscript brings together various preliminary results for the development of micro-sensor type resonant beam.

Page generated in 0.209 seconds