• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 979
  • 18
  • 17
  • 12
  • 12
  • 12
  • 10
  • 9
  • 3
  • 1
  • Tagged with
  • 1020
  • 507
  • 147
  • 141
  • 141
  • 133
  • 124
  • 117
  • 94
  • 94
  • 87
  • 75
  • 64
  • 63
  • 62
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
301

Performance dos métodos visual, radiográfico e baseados em fluorescência na detecção de lesões de cárie: revisões sistemáticas com meta-análises e investigações de fontes de heterogeneidade / Performance of visual, radiographic and fluorescence based methods in detecting carious lesions: systematic reviews, meta-analyses and investigation of sources of heterogeneity

Thais Gimenez Cóvos 13 May 2016 (has links)
O presente estudo teve como objetivo avaliar a performance dos métodos visual, radiográfico e baseados em fluorescência quanto à detecção de lesões de cárie em dentes permanentes e decíduos, realizar meta-análise com a performance global dos métodos e investigar as possíveis fontes de heterogeneidades. Foram realizadas três revisões distintas relacionadas a cada método diagnóstico. Quatro examinadores avaliaram os trabalhos, sendo pelo menos dois por método. Estes efetuaram a busca e seleção de artigos de modo independente; um pesquisador com experiência em trabalhos de diagnóstico de cárie resolveu os casos de conflito ou dúvida. As bases de dados eletrônicas utilizadas foram MEDLINE, EMBASE e Scopus, visando reduzir o viés de publicação, também foram buscados trabalhos acadêmicos e documentos não publicados, através do OpenSigle e Anais do Congresso ORCA. Após a seleção dos estudos por critérios de inclusão e exclusão bem definidos, os dados foram coletados e anotados, de maneira independente por cada revisor. Foi realizada a avaliação da qualidade metodológica através da ferramenta Quality Assessment of Diagnostic Accuracy Studies (QUADAS) e a análise estatística através do Paired Forest Plot, Summary Receiver Operating Characteristics analysis (SROC), relative diagnostic odds ratio (RDOR), análise de sensibilidade e gráfico de funil, além da investigação e exploração das possíveis fontes de heterogeneidade. Para o método visual, 102 artigos preencheram os critérios de inclusão. Em geral, a análise demonstrou que o método visual teve uma boa acurácia para a detecção de lesões de cárie. Embora estudos laboratoriais e clínicos tenham apresentado acurácias semelhantes, os valores de especificidade obtidos clinicamente foram maiores. Observamos, também, moderada a elevada heterogeneidade e evidência de viés de publicação na maioria dos estudos. Além disso, o uso de sistemas de escores visual resultaram em valores significativamente melhores de acurácia em comparação com estudos que utilizaram os seus próprios critérios. Quanto à relevância clínica dos estudos de acurácia do método visual, 96 estudos foram incluídos. Em geral, a maioria dos estudos falha em considerar alguns aspectos clínicos relevantes: somente 1 estudo incluiu avaliação da atividade das lesões; nenhum estudo considerou o seu prognóstico; 79 estudos não consideraram um desfecho clínico relevante e apenas 1 avaliou um desfecho centrado no paciente. Quanto à qualidade metodológica, a maioria dos estudos presentes apresentou alto risco de viés na seleção da amostra. Quanto ao método radiográfico, 116 artigos foram selecionados. Os métodos radiográficos convencional e digital apresentaram desempenho semelhante, mostrando valores maiores de especificidade comparados aos de sensibilidade, além de maiores valores de AUC no limiar de lesões mais avançadas. Quanto aos métodos baseados em fluorescência, 75 estudos preencheram os critérios de inclusão. Em geral, a análise demonstrou uma tendência a valores de acurácia semelhantes para todos os tipos de dentes, superfícies ou tipos de estudo. Houve uma tendência de melhor desempenho na detecção de lesões de cárie mais avançadas. Observamos, também, moderada a alta heterogeneidade e evidência de viés de publicação. Em conclusão, o método visual de detecção de lesões de cárie tem um bom desempenho geral, mas os estudos deveriam considerar desfechos clínicos relevantes, além da acurácia. Além disso, eles deveriam ser conduzidos com maior qualidade metodológica, principalmente em relação à seleção da amostra. Ainda, a utilização de índices detalhados e validados parece melhorar a acurácia do método. O método radiográfico não apresentou diferença entre os modos de aquisição de imagem (digital ou convencional), demonstrando uma tendência a valores superiores de especificidade e melhor desempenho em lesões avançadas. Quanto aos dispositivos baseados em fluorescência, estes mostraram desempenho global semelhante; no entanto, uma melhor acurácia na detecção de lesões de cárie mais avançadas tem sido observada. / This study aimed to evaluate the performance of visual, radiographic and fluorescence-based methods in the detection of caries lesions in permanent and primary teeth, to perform meta-analysis of the overall performance of the methods and to investigate possible sources of heterogeneity. Three distinct systematic reviews related to each diagnostic method were performed. Four observers evaluated the articles, at least two per method. They performed the search and study selection independently; a researcher with experience in caries diagnostic studies solved the cases of conflict or doubt. Electronic databases used were MEDLINE, EMBASE and Scopus, to reduce publication bias, were also pursued academic papers and unpublished documents through OpenSigle and the Annals of ORCA Congress. After the selection of studies by well-defined inclusion and exclusion criteria, data were collected and recorded, independently by each reviewer. Methodological quality assessment was performed through Quality Assessment of Diagnostic Accuracy Studies tool (QUADAS) and statistical analysis using Paired Forest Plot, Summary Receiver Operating Characteristics analysis (SROC), relative diagnostic odds ratio (RDOR), sensitivity analysis and funnel plot, in addition we explored possible sources of heterogeneity. Regarding the accuracy of visual method, 102 articles met the inclusion criteria. In general, visual analysis showed that the method had a good accuracy in the detection of caries lesions. Although laboratory and clinical studies have shown similar accuracies, clinical studies have obtained higher specificities. We also observed moderate to high heterogeneity and evidence of publication bias in most studies. In addition, the use of visual scoring systems resulted in significantly better accuracy compared to studies using their own criteria. Concerning the clinical relevance of accuracy studies of visual method, 96 studies were included. In general, most studies failed to consider some relevant clinical aspects: only 1 study included assessment of activity of the lesions; no study considered their prognosis; 79 studies did not consider a relevant clinical outcome and only 1 evaluated a patient-centered outcome. With regard to the methodological quality, most of the present studies showed a high risk of bias in the selection of the sample. With concern to the radiographic method, 116 articles were selected. Conventional and digital radiographic methods showed similar performance, showing greater specificity values compared to sensitivity, and higher AUC values at the threshold of more advanced caries lesions. Regarding fluorescence-based methods, 75 studies met the inclusion criteria. In general, the analysis demonstrated that the fluorescence-based method tend to have similar accuracy for all types of teeth, dental surfaces or settings. There was a trend of better performance of fluorescence methods in detecting more advanced caries lesions. We also observed moderate to high heterogeneity and evidenced publication bias. In conclusion, the visual method of detecting caries lesions has a good overall performance, but studies should consider relevant clinical outcomes, as well as accuracy. In addition, they should be conducted with greater methodological quality, especially in relation to sample selection. Still, the use of detailed and validated indices seems to improve the accuracy of the method. Radiographic method showed no difference between the image acquisition modes (digital or conventional), showing a tendency to higher values of specificity and performance in advanced caries lesions. Fluorescence-based devices showed similar overall performance; however, a better accuracy in detecting more advanced caries has been observed.
302

Avaliação clínica de peróxidos de hidrogênio em diferentes concentrações: alteração de cor e sensibilidade dental / Clinical evaluation of hydrogen peroxide in different concentration: shade change and sensibility

Silva, Bruna Rozzetti 26 October 2011 (has links)
Objetivo: Avaliar clinicamente o efeito do peróxido de hidrogênio em concentrações de 20%, 30% e 38% no grau de clareamento, assim como a sensibilidade dental antes, após o clareamento e depois de 7, 14 e 30 dias. Material e Método: Foi utilizado um modelo de meia-arcada para comparação dos produtos em um mesmo paciente. Sessenta e nove voluntários foram selecionados e receberam orientações sobre o tratamento a ser realizado. Os voluntários foram divididos aleatóriamente em três grupos, cada grupo contendo 23 pacientes, sendo Grupo 1: Peróxido de hidrogênio 20% versus Peróxido de hidrogênio 30%; Grupo 2: Peróxido de Hidrogênio 20% versus Peróxido de hidrogênio 38%; Grupo 3: Peróxido de hidrogênio 30% versus Peróxido de hidrogênio 38%. Os voluntários receberam duas sessões de clareamento de consultório, com intervalo de 7 dias. A cor dental de incisivos e caninos superiores foi avaliada com uso do espectrofotômetro digital Easyshade antes, após o clareamento e depois de 7, 14 e 30 dias. Para a avaliação da sensibilidade dental, os pacientes responderam a um questionário, com uso de uma escala visual analógica (VAS) antes, durante o clareamento, imediatamente após, após 1 e 24 horas e depois de 7, 14 e 30 dias. Resultados: A análise de variância (ANOVA) mostrou haver diferença estatísticamente significante entre os peróxidos de hidrogênio nas concentrações de 20%, 30% e 38%, entre os dentes caninos e incisivos e entre os períodos, dentro de cada um dos grupos avaliados. O peróxido de hidrogênio 30% apresentou maior alteração de cor dental em comparação às concentrações de peróxido de hidrogênio 20% e 30%. Os dentes caninos apresentaram maiores valores de alteração de cor quando comparados aos incisivos. Em relação à sensibilidade dental, não houve diferença significante entre as concentrações do peróxido de hidrogênio avaliadas (p=0,15), excessão no período durante o clareamento, em que o peróxido de hidrogênio 20% apresentou menor grau de sensibilidade se comparado aos géis de 30% e 38%. Após 24 horas da aplicação dos diferentes peróxidos de hidrogênio, não houve relato de sensibilidade dental. Conclusão: O peróxido de hidrogênio 30% provocou maior alteração de cor dental se comparado aos peróxidos de hidrogênio 20% e 38%. Após 7 dias do tratamento clareador, houve uma estabilização da cor dental em todos os grupos avaliados. / Objective: To clinically evaluate the effect on shade change of hydrogen peroxide in concentrations of 20%, 30% and 38% as well as dental sensitivity, assessed immediately before the whitening treatment and 7,14 and 30 days after. Material and Method: The split arch model was used to compare different products in the same patient. Sixty nine volunteers were selected and instructed on the procedures. The volunteers were randomly divided into 3 groups of 23 patients each. Group 1: hydrogen peroxide 20% versus hydrogen peroxide 30%; Group 2: hydrogen peroxide 20% versus hydrogen peroxide 38%; Group 3: hydrogen peroxide 30% versus hydrogen peroxide 38%. Each patient was submitted to two in office whitening session with a 7 days interval between them. The shade of superior incisives and canines was assesses with a digital Easyshade spectrophotometer immediately before and after the whitening treatment as well as 7,14 and 30 days after treatment. For the dental sensitivity evaluation, patients filled out a questionary, with the aid of a analogical visual scale (VAS) before, during the treatment, after, 1 hour, 24 hours, 7, 14 and 30 days post treatment, Results: ANOVA test showed a statistically significant difference between the different concentration of hydrogen peroxide, and also a statistically significant difference amongst canines and incisive teeth, within each experimental group. Hydrogen peroxide 30% showed greater shade change when compared to hydrogen peroxide 20% and 38%. The canine teeth showed higher shade change when compared to incisive teeth. Regarding dental sensitivity, no statistically significant difference was observed for the different concentrations evaluated (p=0.15). 24 hours after whitening treatment there were no reports of dental sensitivity. Conclusion: Hydrogen peroxide at 30% showed greater shade change when compared to hydrogen peroxide at 20% and 38%. 7 days post whitening treatment all groups evaluated showed shade stability.
303

Avaliação da punção aspirativa por agulha fina (PAAF) em cavidade oral e região de cabeça e pescoço em diferentes técnicas de coloração / Evaluation of Fine Needle Aspiration Biopsy (FNAB) in oral cavity and head and neck region with different techniques stains

Santos, Ana Paula Candido dos 22 August 2014 (has links)
O presente estudo teve como objetivo avaliar a Punção Aspirativa por Agulha Fina (PAAF) em diferentes técnicas de coloração, em lesões nodulares de cavidade oral e região de cabeça e pescoço, quanto a sua sensibilidade, especificidade e acurácia, nas colorações de Panótico, Papanicolau e Hematoxilina-Eosina . Foram selecionados 46 pacientes consecutivamente que procuraram a Clínica da Disciplina de Estomatologia Clínica da FOUSP, portadores de lesões nodulares em cavidade oral e região de cabeça e pescoço. Como critérios de inclusão foram selecionados pacientes de ambos os sexos, todas as etnias, acima dos 5 anos de idade, sem restrição de comorbidades e que foram realizadas PAAF com confirmação diagnóstica pela biópsia. Como critérios de exclusão da pesquisa estão os pacientes abaixo dos 5 anos de idade e pacientes que foram somente submetidos a PAAF sem confirmação diagnóstica pela biópsia. O material obtido pela PAAF foi enviado em 6 lâminas diferentes, corados pelo método de Panótico, Papanicolau e Hematoxilina-Eosina a um mesmo patologista apenas com o diagnóstico clínico. Após a emissão do laudo da PAAF, o laudo do anátomo patológico era emitido, servindo como padrão ouro. Após os cálculos, o resultado da sensibilidade, especificidade e acurácia para o método de coloração com o Panótico foram de 28,6%, 76%, 15,4, respectivamente, para o método de coloração com o Papanicolau foram de 71,4%, 76,7%, 23,3%, respectivamente e para o método de coloração com a Hematoxilina-Eosina foram de 82,1%, 23,3%, 28,6%, respectivamente. Houve diferença estatisticamente significativa na proporção de sensibilidade, especificidade e acurácia entre as diferentes técnicas de coloração (X2 13,27, p=0,01). Podemos concluir que, na metodologia do presente estudo, as colorações de Hematoxilina-Eosina e Papanicolau demonstraram a mesma sensibilidade, para diagnosticar neoplasias malignas. A coloração de Hematoxilina-Eosina demonstrou uma melhor especificidade para diagnosticar neoplasias benignas, quando comparadas com a colorações de Papanicolau e Panótico. A coloração de Hematoxilina-Eosina demonstrou uma melhor acurácia, para dar diagnóstico definitivo, seguida das colorações de Papanicolau e Panótico. / The present study aimed to evaluate the Fine Needle Aspiration Biopsy in different staining techniques in nodular lesions of the oral cavity and head and neck region, as their sensitivity, specificity and accuracy, staining with Panoptic, Papanicolaou and Hematoxylin-Eosin. 46 patients who sought the Clinic of the Discipline of Clinical Stomatology at FOUSP were selected consecutively, with nodular lesions in the oral cavity and head and neck region. Inclusion criteria were patients of both sexes, all ethnicities, above 5 years-old, with no restriction of comorbidities and FNAB performed with confirmation by biopsy. Exclusion criteria were patients under 5 years-old and patients who only underwent FNAB without confirmation by biopsy. The material obtained by FNAB was sent on 6 different slides, stained by the method of Panoptic, Papanicolaou and Hematoxylin-Eosin, to the same pathologist only with the clinical diagnosis. After the final report of FNAB, the biopsy report was issued, serving as gold standard. After the calculations, the results of sensitivity, specificity and accuracy for Panoptic staining were 28.6%, 76% and 15.4%, respectively. The result of sensitivity, specificity and accuracy for Papanicolaou staining were 71,4%, 76.7% and 23.3%, respectively. The result of sensitivity, specificity and accuracy for Hematoxylin-Eosin staining were 82.1%, 23.3%, 28.6%, respectively. There was a statistically significant difference in the proportion of sensitivity, specificity and accuracy between the different staining techniques (X2 13.27, p = 0.01). We can conclude, in the methodology of this study that, Hematoxylin-Eosin and Papanicolaou stains showed the same sensitivity of diagnosing malignant neoplasms. The Hematoxylin-Eosin stain showed a better specificity for diagnosing benign neoplasms, compared with Papanicolaou and Panoptic stains. Hematoxylin-eosin stain showed better accuracy, to give definitive diagnosis, followed by Papanicolaou and Panoptic stains.
304

Análise de sensibilidade dos parâmetros de cálculo das coberturas jardim

Ferreira, Ricardo Jorge da Silva January 2013 (has links)
Tese de mestrado integrado. Engenharia Civil (Construções). Faculdade de Engenharia. Universidade do Porto. 2013
305

Corpo Híbrido / -

Silva, Viviane Vallades da 12 June 2019 (has links)
Esta pesquisa teve como objetivo a realização de experimentos poéticos em artes visuais, que também foram o seu objeto de estudo. Os experimentos pretenderam explorar imagens de meu corpo em seus estados transitórios, realizando ações e modificações, por meio de peles artificiais e máscaras e acrescentando dispositivos ao corpo, produzindo sensações visuais, táteis, auditivas, espaciais e temporais que buscam gerar reflexões sobre os corpos dos seres em geral. Através das ações que meu corpo realiza ou, em alguns outros trabalhos, por meio de palavras que remetem ao corpo e a seus comportamentos, pretendi produzir sensações e ficções que discutem questões ligadas à existência cotidiana como: relações sociais, efemeridade, mutações da sensibilidade, subjetividade, relação humano-máquina e mecanização dos sentimentos. / This research aimed to carry out poetic experiments, which were also its object of study. The experiments attempted to explore images of my body in its transient states, performing actions and modifications, using artificial skins and masks, adding devices to the body, producing visual, tactile, auditory, spatial and temporal sensations which seek to generate reflections on the bodies of beings in general. Through the actions that my body performs or in some other works, through words that refer to the body and its behaviors, I intend to produce sensations and fictions that discuss issues related to daily existence such as: social relations, ephemerality, sensitivity mutations, subjectivity, human-machine relationship and mechanization of feelings.
306

Arte e utopia em Herbert Marcuse / Art and Utopia in Herbert Marcuse

Kunz, Cibele Saraiva 26 August 2019 (has links)
Esta tese pretende acompanhar o desenvolvimento da relação entre arte e utopia na obra de Herbert Marcuse. Para tanto, é necessário entender como o autor desenvolve a relação entre sensibilidade e transformação social nos seus escritos estéticos-políticos. É igualmente importante dialogar com autores tradicionais e contemporâneos da filosofia, como Schiller, Mannheim, Bloch e o círculo da teoria crítica da qual Marcuse fez parte. Partindo da ideia de que Marcuse não trata o tema da utopia de forma homogênea em toda sua obra, mas que esta está sempre relacionada com o papel da arte de negação do status quo, e tendo como base a realidade histórica em que seus textos foram escritos, são discutidas as contribuições e limitações da teoria estética marcuseana para o debate filosófico contemporâneo e a possibilidade de denominá-la utópica. Marcuse, como crítico do Marxismo ortodoxo, retoma propostas debatidas por socialistas utópicos como Fourier e, assim como Bloch, é responsável por resgatar a importância da questão da sensibilidade no discurso socialista. Trazer o debate da sensibilidade para o discurso político é um dos grandes legados de Marcuse. / This thesis intends to follow the development of the relationship between art and utopia in the work of Herbert Marcuse. Therefore, it is necessary to understand how the author develops the relationship between sensibility and social change in his aesthetic-political writings. It is also important to dialogue with the traditional and contemporary authors of the philosophy, such as Schiller, Mannheim, Bloch and the circle of critical theory of which Marcuse was a part. Considering that Marcuse does not treat the theme of utopia in a consistent manner across his work, but that it is always related to the role of art of negating the status quo, and based on the historical context in which his texts were written, the contributions and limitations of the marcusean aesthetic theory to the contemporary philosophical debate are discussed, as well as the possibility of calling it utopian. Marcuse, as a critic of orthodox Marxism, revisits proposals debated by utopian socialists such as Fourier and, like Bloch, he is responsible for recovering the importance of the issue of sensibility in the socialist discourse. Bringing the debate of sensibility into the political discourse is one of Marcuse\'s great legacies.
307

Sensibilidade ambiental a hidrocarbonetos para rodovias: estudo de caso em trecho da Rodovia Anhanguera (SP-330) / Environmental sensitivity to hydrocarbons for highways: a case study of the Anhanguera Highway (SP-330)

Ferreira, Mayara Nicolau [UNESP] 26 October 2017 (has links)
Submitted by Mayara Nicolau Ferreira null (mayara_feni@outlook.com) on 2017-12-13T19:33:50Z No. of bitstreams: 1 Dissertação final para o cd.pdf: 8263943 bytes, checksum: a933228a9bd4ca5a348d316c828ae92d (MD5) / Submitted by Mayara Nicolau Ferreira null (mayara_feni@outlook.com) on 2017-12-14T11:25:01Z No. of bitstreams: 1 Dissertação final para o cd.pdf: 8263943 bytes, checksum: a933228a9bd4ca5a348d316c828ae92d (MD5) / Submitted by Mayara Nicolau Ferreira null (mayara_feni@outlook.com) on 2017-12-14T13:50:30Z No. of bitstreams: 1 Dissertação final para o cd.pdf: 8263943 bytes, checksum: a933228a9bd4ca5a348d316c828ae92d (MD5) / Approved for entry into archive by Adriana Aparecida Puerta null (dripuerta@rc.unesp.br) on 2017-12-14T16:02:31Z (GMT) No. of bitstreams: 1 ferreira_mn_me_rcla.pdf: 8244618 bytes, checksum: f6eec6ad55c4fa070d073f0df07c532a (MD5) / Made available in DSpace on 2017-12-14T16:02:31Z (GMT). No. of bitstreams: 1 ferreira_mn_me_rcla.pdf: 8244618 bytes, checksum: f6eec6ad55c4fa070d073f0df07c532a (MD5) Previous issue date: 2017-10-26 / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Considerando o crescente número de acidentes com produtos perigosos em rodovias e que este é o modal mais utilizado para o transporte de cargas no Brasil, principalmente hidrocarbonetos e derivados de petróleo. Bem como, os insipientes estudos de índices de sensibilidade ambiental para ambientes terrestres. E que os mapas de sensibilidade são importantes ferramentas técnico-gerenciais utilizadas na tomada de decisões emergenciais em caso de combate a derrames de óleo. Além de fornecer informações para o planejamento de contenção e limpeza para mitigar os impactos ambientais, auxiliar a identificação de locais sensíveis antes que ocorra o acidente, de modo que as estratégias de proteção e contenção possam ser organizadas antecipadamente, objetiva-se a confecção de um índice de sensibilidade ambiental aos hidrocarbonetos para rodovias, utilizando como área de estudo um trecho da Rodovia Anhanguera (SP-330), segunda maior em números de acidentes com produtos perigosos no estado de São Paulo, e sua respectiva carta de sensibilidade ambiental. Para tanto, procede-se fazendo uso de geotecnologias para confecção de mapas básicos necessários a pesquisa; da compartimentação fisiográfica para dividir a área de estudo em zonas homólogas; do trabalho de campo para corroborar a compartimentação; da escolha dos cinco parâmetros e seus respectivos pesos, que compõem o índice de sensibilidade ambiental aos hidrocarbonetos para rodovias; e consequentemente, a confecção da carta de sensibilidade ambiental. Desse modo, observa-se que no trecho foram encontrados os índices 5, 7 e 8, sendo que o índice 7 é predominante em seis das oito Unidade Básicas de Compartimentação, o que permite concluir que a área estudada tem média-alta sensibilidade ambiental, levando em consideração que o índice vai de 1 a 10 A. Além de colaborar com o desenvolvimento de uma adaptação do método das cartas SAO utilizadas em ambientes costeiros e fluviais para um índice de sensibilidade ambiental aos hidrocarbonetos para rodovias. Por fim, conclui-se que o mapeamento de sensibilidade ambiental aos hidrocarbonetos para o modal rodoviário apresenta-se viável a partir da aplicação de um método adequado ao ambiente em que está inserido e o método da compartimentação fisiográfica foi extremamente apropriado e eficaz para os ambientes terrestres. / Considering the increasing number of accidents with hazardous products on highways and that this is the most used modal for the transport of cargoes in Brazil, mainly hydrocarbons and petroleum products. As well as, the insipient studies of environmental sensitivity indexes for terrestrial environments. And that sensitivity maps are important technical and managerial tools used in making emergency decisions in case of combating oil spills. In addition to providing information for containment and cleanup planning to mitigate environmental impacts, assisting the identification of sensitive locations before the accident occurs, so that protection and containment strategies can be organized in advance, it is aimed to create an Index of environmental sensitivity to hydrocarbons for highways, using as an area of study a section of the Anhanguera Highway (SP-330), second largest in numbers of accidents with dangerous products in the state of São Paulo, and its respective letter of environmental sensitivity. To do so, we make use of geotechnologies to create basic maps necessary for the research; the physiographic compartmentalization to divide the study area into homologous zones; the fieldwork to corroborate the compartmentalization; the choice of the five parameters and their respective weights, which make up the environmental sensitivity index for hydrocarbons for highways; and consequently, the preparation of the environmental sensitivity letter. Therefore, it can be observed that the indexes 5, 7 and 8 were found in this section, with index 7 being predominant in six of the eight Basic Compartmental Units, which allows to conclude that the studied area has medium-high environmental sensitivity, taking into account that the index ranges from 1 to 10 A. In addition to collaborating with the development of an adaptation of the SAO letters used in coastal and fluvial environments to an environmental sensitivity index to hydrocarbons for highways. Finally, it is concluded that the mapping of environmental sensitivity to hydrocarbons for the road modal is feasible from the application of a method appropriate to the environment in which it is inserted and the physiographic compartmentalization method was extremely appropriate and effective for the land environments.
308

Análise de sensibilidade por redes neurais para estudos da estabilidade transitória de sistemas elétricos de potência

Lotufo, Anna Diva Plasencia [UNESP] 30 August 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:30:52Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-08-30Bitstream added on 2014-06-13T19:00:52Z : No. of bitstreams: 1 lotufo_adp_dr_ilha.pdf: 1403044 bytes, checksum: 249ef360105db325454067aab8f18bbe (MD5) / Esta pesquisa tem por objetivo o desenvolvimento de uma metodologia, para análise de estabilidade transitória e para o controle preventivo de sistemas de energia elétrica, formulada por redes neurais feedforward multicamadas. A margem de segurança (método da energia) é empregada como critério de análise de estabilidade transitória, considerando-se defeitos tipo curto-circuito trifásico com saída de linha de transmissão. O funcionamento das redes neurais é constituído por duas fases principais: treinamento (ou aprendizado) e análise. A fase de treinamento requer uma grande quantidade de processamento para a sua realização, enquanto que a fase de análise é efetivada, praticamente, sem esforço computacional. Trata-se, por conseguinte, da principal justificativa para o uso de redes neurais para a resolução de problemas complexos que exigem soluções rápidas, sendo, portanto, adequadas para aplicações em tempo real. O treinamento da rede neural é realizado usando o algoritmo retropropagação (backpropagation) com controlador nebuloso e a adaptação da inclinação e deslocamento da função sigmóide (pós-sináptica). O controlador nebuloso é usado visando proporcionar uma convergência mais rápida e resultados mais precisos, se comparado ao algoritmo retropropagação tradicional. A adaptação da taxa de treinamento é efetuada usando a informação do erro global e a variação do erro global. A adaptação da inclinação e deslocamento da função sigmóide também é usada com o objetivo de melhorar a capacidade da obtenção de uma solução, ou seja, ampliar o espaço de busca. Após ter sido concluído o treinamento, a rede neural deverá estar apta a estimar a margem de segurança e a análise de sensibilidade. Com esta informação é possível desenvolver um método para a realização da correção da segurança (controle preventivo)... . / This work presents a procedure, for transient stability analysis and for preventive control of electric power systems, formulated by multilayer feedforward neural network. The security margin (energy method) is used as a criterion of the transient stability analysis considering faults like three-phase short-circuits with outage of transmission line. The performance of neural networks is constituted of two principal phases: training (or learning) and analysis. The training phase needs a great quantity of processing time for the realization, whereas the analysis phase is effectuated almost without computational effort. Therefore, this is the principal justification to use neural networks for solving complex problems that need fast solutions, and as a consequence being adequate for real time applications. The neural network training is realized using the backpropagation algorithm with fuzzy controller and the sigmoid (postsynaptic) function slope and translation adaptation. The fuzzy controller is used to provide a faster convergence and more precise results, if compared to the traditional Backpropagation algorithm. The adapting of the training rate is effectuated using the information of the global error, and global error variation. The adaptation of the slope and translation of the postsynaptic function is used for improving the capacity of obtaining a solution, i.e., to enlarge the space of search. After finishing the training, the neural network is capable to estimate the security margin, and the sensitivity analysis. With these information it is possible to develop a method for the realization of the security correction (preventive control) based on generation reallocation and load shedding. The preventive control idealization is based on the sensitivity... (Complete abstract, click electronic address below).
309

Influência da espessura da cerâmica, do tempo de fotopolimerização e do cimento resinoso na resistência de união à microtração de uma cerâmica vítrea cimentada à dentina humana

Barca, Diana Capelli [UNESP] 07 July 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-07-07Bitstream added on 2014-06-13T18:35:10Z : No. of bitstreams: 1 barca_dc_me_sjc.pdf: 4808947 bytes, checksum: 238892d410325de1d23eb76694cb9763 (MD5) / Este estudo avaliou a influência da espessura da cerâmica, do tempo e tipo de fotopolimerização do cimento resinoso na resistência da união entre uma cerâmica vítrea e a dentina coronária humana. A hipótese é a de que o tipo e o tempo de fotopolimerização do agente cimentante e a espessura da cerâmica influenciem na resistência de união entre cimento e dentina. Foram selecionados cento e doze dentes molares humanos hígidos que foram incluídos em resina acrílica e tiveram a superfície oclusal cortadas em máquina Labcut, expondo a dentina planificada. Dois grupos foram tiveram a dentina condicionada com ácido fosfórico 37% lavada e aplicado adesivo (Excite, Ivoclar) fotopolimerizando por 20s. No grupo controle (n=16), utilizou-se cimento auto-adesivo. Foram confeccionados cento e doze blocos (6 x 6 mm) de cerâmica feldspática (Vita PM9) com três espessuras: 1, 2 e 3 mm que tiveram a superfície de cimentação tratad a com ácido fluorídrico 10%, lavada, seca e silanizada. Os blocos cerâmicos foram cimentados, de acordo com o grupo experimental: Variolink II (Ivoclar Vivadent); e fotopolimerizados com LED por 40 ou 80 segundos de fotopolimerização ou cimento Multilink II (no grupo controle). Assim, formaram-se sete grupos (n=16). Os espécimes foram armazenados em água destilada (37°C) por 24 horas e seccionados em dois eixos, X e Y, para a obtenção dos espécimes. Cada grupo (N=16) foi subdividido em 2 (n=8) onde um grupo foi termociclado e o outro submetido ao ensaio de microtração 24 horas após a cimentação. Esse palito (cerâmica/dente) foi fixado no dispositivo de microtração Erios, levado à máquina de ensaio universal e testado com velocidade de 1 mm/min. Os valores médios obtidos (MPa) foram à análise de Variáveis ANOVA 3- fatores, teste de Dunnett e ao teste de Tukey (5%). A resistência adesiva foi significantemente influenciada pelos fatores... / This study evaluated the influence of the thickness of the ceramic, time and type of light curing resin cement on bond strength between a ceramic and glass human dentin. The hypothesis is that the type and time of curing luting agent and the thickness of the ceramic bearing on the bond strength between cement and dentin. We selected one hundred and twelve healthy human molar teeth were embedded in acrylic resin and were cut in the occlusal surface Labcut machine, exposing the dentin. Two groups have had to dentin conditioned with 37% phosphoric acid washed applied adhesive (Excite, Ivoclar) light cured for 20s. In the control group (n = 16), we used self-adhesive cement. We made one hundred and twelve blocks (6 x 6 mm) ceramic feldspathic (Vita PM9) with three thicknesses: 1, 2 and 3 mm that had cement surface treated with hydrofluoric acid 10%, washed, dried, and silanized. The ceramic blocks were cemented according to the experimental group: Variolink II (Ivoclar Vivadent) and cured with LED for 40 or 80 seconds of curing cement Multilink or II (control group). Thus, they formed seven groups (N = 16). The specimens were stored in distilled water (37 ° C) for 24 hours and sectioned in two axes, X and Y, to obtain the specimens. Each group (N = 16) was subdivided into two (n = 8) where a group was thermocycled and another test by microtensile 24 hours after cementation. This toothpick (ceramic / tooth) was mounted in microtensile Erios, led to a universal testing machine and tested at a speed of 1 mm / min. The average values (MPa) were the ANOVA analysis of three variables - factors, Dunnett test and Tukey test (5%). The bond strength was significantly influenced by light irradiation time, thickness of the ceramic thermal cycling
310

Avaliação do Clinpro XT® na redução da permeabilidade da dentina radicular e resistência a desafios ácidos, na obliteração de túbulos dentinários e rugosidade superficial da dentina / Clinpro XT® evaluation in reducing the permeability of root dentin and resistance to acids challenges, the obliteration of dentinal tubules and surface roughness of dentin

Terenzi, Mayara [UNESP] 23 March 2016 (has links)
Submitted by MAYARA TERENZI null (mayara_terenzi@hotmail.com) on 2016-05-01T13:15:46Z No. of bitstreams: 3 Dissertação de Mestrado - Mayara Terenzi.pdf: 1718757 bytes, checksum: 20f87c0423de8d0417680da47944a37f (MD5) Anexo A.pdf: 90620 bytes, checksum: 7670a876bb4321d72791935fcb19bfe4 (MD5) Anexo B.tif: 7046482 bytes, checksum: ba852948774319d877a6088b781b43b7 (MD5) / Rejected by Felipe Augusto Arakaki (arakaki@reitoria.unesp.br), reason: Solicitamos que realize uma nova submissão seguindo as orientações abaixo: Foram submetidos 2 arquivos PDF’s e 1 arquivo TIF, a dissertação/tese deve estar em um único arquivo, inclusive os apêndices e anexos e deve estar no formato PDF. Lembramos que o arquivo PDF não deve estar protegido. Corrija estas informações e realize uma nova submissão contendo o arquivo correto. Agradecemos a compreensão. on 2016-05-04T13:37:28Z (GMT) / Submitted by MAYARA TERENZI null (mayara_terenzi@hotmail.com) on 2016-05-10T17:37:12Z No. of bitstreams: 1 Dissertação Mayara 100516.pdf: 8045470 bytes, checksum: 53ac4e21e2f77379964f4bc5b09e8f7a (MD5) / Approved for entry into archive by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br) on 2016-05-12T19:23:37Z (GMT) No. of bitstreams: 1 terenzi_m_me_arafo.pdf: 8045470 bytes, checksum: 53ac4e21e2f77379964f4bc5b09e8f7a (MD5) / Made available in DSpace on 2016-05-12T19:23:37Z (GMT). No. of bitstreams: 1 terenzi_m_me_arafo.pdf: 8045470 bytes, checksum: 53ac4e21e2f77379964f4bc5b09e8f7a (MD5) Previous issue date: 2016-03-23 / O completo entendimento e tratamentos eficazes e definitivos para a hipersensibilidade dentinária, ainda não estão estabelecidos. O grande desafio está em encontrar uma substância que elimine efetivamente a sensação dolorosa não permitindo sua recidiva. O objetivo deste estudo in vitro foi determinar a eficácia do Clinpro XT® na redução da permeabilidade dentinária e avaliar a resistência deste produto a desafios ácidos. O grau de obliteração dos túbulos dentinários e a rugosidade superficial após aplicação do produto, também foram avaliados. Foram utilizados 65 terceiros molares humanos íntegros para a preparação de 65 amostras que foram ligadas a um sistema de pressão hidráulico para mensurar a permeabilidade dentinária após os seguintes passos: (1) preparação da amostra; (2) tratamento com ácido fosfórico a 37% durante 30 segundos; (3) aplicação do Clinpro XT®; (4) primeiro; (5) segundo e (6) terceiro desafios ácidos, respectivamente. As amostras foram divididas aleatoriamente em 5 grupos (n = 13) de acordo com as diferentes soluções ácidas: refrigerante a base de cola, suco natural de limão, vinagre de vinho, vinho branco e energético. 10 terceiros molares adicionais foram utilizados para a preparação de 20 amostras para análise do grau de obliteração dos túbulos dentinários, através da microscopia eletrônica de varredura, e, rugosidade superficial, através de um rugosímetro. Pode-se concluir que Clinpro XT® foi eficaz na redução da permeabilidade dentinária e esse efeito se manteve após três desafios com diferentes substâncias ácidas. Além disso, o produto testado foi capaz de promover a obliteração dos túbulos dentinários e a redução da rugosidade superficial. / The complete understanding and effective and definitive treatment for dentin hypersensitivity are not yet established. The challenge is to find a substance that effectively eliminates the painful sensation not allowing their recurrence. The purpose of this in vitro study was to determine the efficacy of Clinpro XT® in reducing dentin and evaluate the strength of the product acid challenges. The obliteration of the dentinal tubules, and surface roughness after application of the product, were also evaluated. 65 intact human third molars were used for the preparation of 65 samples were bound to a hydraulic pressure system to measure the dentin after the following steps: (1) sample preparation; (2) treatment with 37% phosphoric acid for 30 seconds; (3) application of Clinpro XT®; (4) first; (5) and second (6) third challenges acids, respectively. The samples were randomly divided into 5 groups (n = 13) according to the different acid solutions: refrigerant cola, natural lemon juice, wine vinegar, white wine and energy drink. 10 thirds additional molars were used to prepare 20 samples for analysis of the degree of obliteration of the dentinal tubules, by scanning electron microscopy, and surface roughness, using a roughness. It can be concluded that Clinpro XT® was effective in reducing dentinal permeability and this effect was maintained after three challenges with different acids. Furthermore, the test product is capable of promoting the obliteration of the dentinal tubules and reduce surface roughness.

Page generated in 0.0856 seconds