SIMULTÂNEA DE METAIS EM BIODIESEL, POR VOLTAMETRIA DE REDISSOLUÇÃO ANÓDICA USANDO ELETRODO DE FILME DE MERCÚRIO EM MEIO ALCÓOLICO / SIMULTANEOUS METAL IN BIODIESEL BY VOLTAMMETRY ANODIC STRIPPING USING MERCURY FILM ELECTRODE IN ALCOHOLIC MEDIUM

Frazão, érica Vanessa Pereira 27 April 2010 (has links)
Made available in DSpace on 2016-08-19T12:56:33Z (GMT). No. of bitstreams: 1 Erica Vanessa Pereira Frazao.pdf: 2235580 bytes, checksum: f883fcc3dc6ec2ecc825185fbd7d95b2 (MD5) Previous issue date: 2010-04-27 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / Diferential pulse and square wave anodic stripping voltammetry at the mercury film electrode, prepared in the ex-situ and in-situ modes, showed an adequate analytical performance and were employed for the development of a procedure for analysis of Biodiesel. Samples were simply diluted into a methanol solution to a final concentration of 0.33 mol L-1 (v/v) acetic acid in order to convert the analytes to their inorganic form. Supporting electrolyte was evaluated among several (1x10-2 mol L-1 LiCl, 5x10-2 mol L-1 H2SO4 in ethanol media and CH3COONa 1x10-2 mol L-1 and CH3COOH 2% in methanol media). 2% (3.3x10-1 mol L-1) acetic acid in methanol media was chosen, and the pH adjusted to a final value of 4.5 with NaOH (2.0 mol L- 1) due to its ability to provide adequate solubility for biodiesel. After several voltammetric experiments in the absence and presence of increasing aliquots of pure biodiesel and metal standard solution, the ideal set of voltammetric procedure for the simultaneous determination of metals was obtained as following: Edep: -1.0 V; Efinal: 0.1 V; tdep: 160 s, amplitude: 75 mV, frequency: 20 Hz. Voltammograms and their corresponding standard curves indicated that the procedure for simultaneous determination is viable. The results obtained indicated that anodic stripping voltammetry in the square-wave mode (SVSW) shown extremely useful and more sensitive results than pulse diferential mode for simultaneous measurements of metal trace in B100 at nanomolar level. On the other hand linear sweep stripping voltammetry did not presented sensitivity enough in the studied conditions. The experiments carried out by adding successive aliquots of a standard mixed solution of Pb, Cu and Cd (1x10-5 mol L-1), provided a linear response between current and concentration of metals (correlation coefficient for lead and copper were respectively 0.996 and 0.997 (EFM prepared ex-situ) and 0.996, 0.990 and 0.990 (EFM prepared insitu) for lead, copper and cadmium metals). Each sample of biodiesel was analyzed in triplicate. In-situ and ex-situ mercury film electrodes were evaluated showing both appropriate analytical performance. The procedures showed very good results of statistical evaluation for a 95% of confidence level. / Voltametria de redissolução nos modos pulso diferencial e onda quadrada, usando eletrodos de filme de mercúrio, preparados no modo ex-situ e in-situ, mostraram um desempenho analítico adequado e foram empregadas para o desenvolvimento de um procedimento de análise de Biodiesel. As amostras foram simplesmente diluídas em uma solução de ácido acético em metanol para uma concentração final de 3,3x10-1 mol L-1 (v / v), a fim de transformar os analitos para sua forma inorgânica. O eletrólito suporte foi escolhido entre vários (LiCl 1x10-2 mol L-1, H2SO4 5x10-2 mol L-1 em meio etanólico e CH3COONa 1x10-2 mol L-1 e CH3COOH 2% em meio metanólico), como eletrólito suporte, porque estas condições proporcionaram uma solubilidade adequada e melhor para o biodiesel. O eletrólito suporte foi preparado através do ajuste de pH de uma solução de ácido acético 2% em metanol com NaOH (2,0 mol L-1) para um valor final de 4,5. Após de vários experimentos voltamétricos, na ausência e presença de alíquotas crescentes de biodiesel e soluções padrões mistas dos íons metálicos, as condições ideais para a determinação simultânea de metais pelas técnicas voltamétricas foram as seguintes: Edep: -1,0 V; tdep: 160s; Efinal: 0,1 V; amplitude de 75 mV, frequencia: 20 Hz. Os voltamogramas e suas correspondentes curvas padrão indicaram que o procedimento para a determinação simultânea é viável. Os resultados obtidos indicam que a voltametria de redissolução anódica no modo de onda quadrada (SWV) apresentou resultados extremamente úteis e mais sensíveis do que os resultados obtidos no modo de pulso diferencial, para medidas simultâneas dos metais traço em B100, no nível nanomolar. A voltametria de redissolução no modo de varredura linear não apresentou sensibilidade suficiente nas condições estudadas. Os experimentos realizados pela adição sucessiva de alíquotas de uma solução padrão mista dos íons Cd2+, Pb2+ e Cu2+ (1x10-5 mol L-1), proporcionaram uma resposta linear da corrente de pico com a concentração dos metais (coeficiente de correlação para chumbo e cobre foram, respectivamente, 0,996 e 0,997 (EFM preparado ex-situ) e 0,996, 0,990 e 0.990 (EFM preparado in-situ para os metais chumbo, cobre e cádmio). Cada amostra de biodiesel foi analisada em triplicata. O novo método proposto mostrou resultados muito bons referente a avaliação estatística, no intervalo de confiança de 95%.
42

PROCEDIMENTO VOLTAMÉTRICO OTIMIZADO PARA DETERMINAÇÃO DE Ni2+ EM AMOSTRAS PRÉ-TRATADAS DE BIODIESEL, USANDO ELETRODO MODIFICADO COM FILME DE MERCÚRIO / PROCEDURE OPTIMIZED VOLTAMMETRIC FOR DETERMINATION OF Ni2 + IN PRE-TREATED SAMPLES OF BIODIESEL, USING MODIFIED ELECTRODE WITH FILM OF MERCURY

Nobre, Eva Michelly Carvalho Santana 04 July 2011 (has links)
Made available in DSpace on 2016-08-19T12:56:36Z (GMT). No. of bitstreams: 1 dissertacao Eva.pdf: 1581206 bytes, checksum: 1aebd130343ea1ba16d040c34b337e22 (MD5) Previous issue date: 2011-07-04 / The presence of metals in biodiesel can be related to raw material, the process used to obtain biodiesel or its storage and can cause reactions of oxidation, corrosion and clogging engines, besides causing risks to human health and the environment. In this paper, we propose a procedure based on voltammetric experimental conditions suitable for the determination of Ni2+ ion in biodiesel (B100) through Square Wave Adsorptive Stripping Voltammetry, using the mercury film electrode prepared ex situ. First, the mercury film was prepared and then was conducted the analysis of a biodiesel pre-treated (digested) sample. The sample digestion was performed with microwave oven in a closed system in the presence of ultra-pure nitric acid and hydrogen peroxide. After this, ammonia buffer 0.01 mol L-1 pH 9.23 and NaOH 0.46 mol L-1 was added into the cell to adjust the pH of the sample to a final value of approximately 9.2. Finally, the chelator dimethylglyoxime (DMG) 0.01 mol L-1 was added, which acts as a complexing element to capture the Ni2+ ion. Next, several voltammetric experiments, in the absence and presence of increasing aliquots of biodiesel and standard solution of the metallic ion, were performed to optimize the analysis conditions. The results indicate that the Square Wave Adsorptive Stripping Voltammetry (VAdRSWV) appeared suitable for measurements of trace metal in Biodiesel (B100) in concentrations up to 10-8 mol L-1. The experiments carried out by successive addition of aliquots of a standard solution of Ni2+ ions provided a linear response of peak current with the concentration of metal ion. Each sample of biodiesel was analyzed in triplicate, with very satisfactory results from the analytical point of view, once we were dealing with trace element analysis, especially in terms of accuracy (recovery 105%) and precision (RSD 9.61%) for the Ni2+ metal ion, using a confidence limit of 98%. / A presença de metais no biodiesel pode estar relacionada com a matéria-prima, com o processo utilizado para a obtenção do biodiesel ou com sua estocagem e pode provocar reações de oxidação, corrosão e entupimento em motores, além de causar riscos à saúde humana e ao meio ambiente. Neste trabalho, é proposto um procedimento voltamétrico com base em condições experimentais adequadas para a determinação do íon Ni2+ em biodiesel (B100) por Voltametria Adsortiva de Redissolução no modo Onda Quadrada, usando o eletrodo de Filme de Mercúrio preparado no modo ex situ. Inicialmente, o filme de mercúrio foi preparado e a seguir realizaram-se as análises com amostra de biodiesel pré-tratada (digerida). A digestão da amostra foi realizada com forno de micro-ondas em sistema fechado, na presença de ácido nítrico ultra-puro e peróxido de hidrogênio. Após essa etapa, foi adicionado tampão amônia 0,01 mol L-1 pH 9,23 e NaOH 0,46 mol L-1 na célula para ajustar o pH da amostra para um valor final de aproximadamente 9,2. Por fim, foi adicionado o quelante dimetilglioxima (DMG) 0,01mol L-1 que funciona como complexante para captura do íon Ni2+. Após esta etapa, vários experimentos voltamétricos, na ausência e presença de alíquotas crescentes de biodiesel e solução padrão do íon metálico foram realizados para otimizar as condições de análise. Os resultados obtidos indicam que a Voltametria Adsortiva de Redissolução no modo Onda Quadrada (VAdRSWV) apresentou resultado satisfatório para medidas do metal traço em Biodiesel (B100), em concentrações de até 10-8 mol L-1. Os experimentos realizados pela adição sucessiva de alíquotas de uma solução padrão do íon Ni2+ proporcionaram uma resposta linear da corrente de pico com a concentração do íon metálico. Cada amostra de biodiesel foi analisada em triplicata, apresentando resultados bastante satisfatórios do ponto de vista analítico por se tratar de análise de elementos traços, principalmente, em termos de exatidão (recuperação de 105 %) e precisão (DPR de 9,61%), para o íon metálico Ni2+, utilizando um limite de confiança de 98%.
43

DETERMINAÇÃO DE CÁDMIO E CHUMBO EM BIODIESEL POR VOLTAMETRIA DE PULSO DIFERENCIAL E DE REDISSOLUÇÃO ANÓDICA USANDO ELETRODO DE FILME DE BISMUTO EM MEIO ETANÓLICO / DETERMINATION OF CADMIUM AND LEAD IN BIODIESEL BY DIFFERENTIAL PULSE VOLTAMMETRY ANODIC STRIPPING USING AND FILM ELECTRODE BISMUTH IN MEDIUM ETHANOL

Guimarães, Myrna Barbosa 13 June 2011 (has links)
Made available in DSpace on 2016-08-19T12:56:37Z (GMT). No. of bitstreams: 1 Dissertacao Myrna Guimaraes.pdf: 1171373 bytes, checksum: ff939c3059a58da4ec3c89bdd21abd27 (MD5) Previous issue date: 2011-06-13 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This work presents a simple procedure based on technique anodic stripping voltammetry (ASV) to determine Cd2+ and Pb2+ in Biodiesel (B100), without prior sample treatment, using a bismuth film electrode (BiFE), prepared as ex situ mode. Samples were simply diluted into a 0.1 mol L-1 acetate buffer ethanolic (pH 4.5), being the pH apparent (pH*) adjusted with HCl 1 mol L-1 before analysis. This intended to provide the conversion of the analytes to their inorganic forms. After optimization of the voltammetric and experimental conditions, the parameters ideal values for the determination of these metals were obtained as following: deposition potential: -1.4 V; deposition time: 180 s; scan rate: 25 mV s-1; modulation amplitude: 50 mV; pH apparent (pH*) ~ 2.0. The voltammograms and their corresponding standard analytical curves indicated that BiFE associated with ASV in the diferential pulse mode (DPASV) provide useful and sensitive procedure for determination of metal in B100 at trace level. The results showed a linear response between current and concentration of Cd2+ and Pb2+ ions. Adequates detection limits (3s, n = 5) were obtained for Cd2+ (1.71x10-8 mol L-1) and Pb2+ (1.92x10-9 mol L-1) for the analysis of B100. The accuracy was assessed by the recovery test (recoveries of 97 to 100 % for Cd2+ and 87 to 107 % for Pb2+). The precision expressed by coefficient of variation was less than 10 % for Cd2+ and less than 7 % for Pb2+. The method was applied successfully to four different biodiesel samples analyzed in triplicate. Pb2+ was quantified in three samples while Cd2+ only was found in two of the four analysed samples. The procedure showed good analytical results for a 95% of confidence level. / Este trabalho apresenta um procedimento simples baseado na técnica voltametria de redissolução anódica (ASV) para determinar Cd2+ e Pb2+ em Biodiesel (B100), sem pré tratamento da amostra, usando eletrodos de filme de bismuto (BiFE), preparado no modo ex situ. As amostras foram simplesmente diluídas em uma solução etanólica de tampão acetato, 0,1 mol L-1 (pH 4,5), sendo o pH aparente (pH*) ajustado com HCl 1 mol L-1 antes das análises. Isto foi feito com a intenção de proporcionar a conversão dos analitos para suas formas inorgânicas. Depois da otimização das condições experimentais e voltamétricas, os valores ideais dos parâmetros para a determinação dos metais foram obtidos, e são os seguintes: potencial de deposição: -1,4 V; tempo de pré-concentração: 180 s; velocidade de varredura: 25 mV s-1; amplitude de pulso: 50 mV; pH aparente (pH*) ~ 2,0. Os voltamogramas e suas curvas analíticas-padrão correspondentes indicaram que o BiFE associado com a técnica ASV no modo pulso diferencial (DPASV) proporciona um procedimento útil e sensível para a determinação de metais em B100 no nível de traços. Os resultados mostraram uma resposta linear entre a corrente de pico e a concentração dos íons Cd2+ e Pb2+. Adequados limites de detecção (3s, n = 5) foram obtidos para Cd2+ (1,7x10-8 mol L-1) e Pb2+ (1,9x10-9 mol L-1) para a análise em B100. A exatidão foi avaliada por testes de recuperação (recuperações de 97 a 100 % para Cd2+ e 87 a 107 % para Pb2+). A precisão, expressa pelo coeficiente de variação foi menor que 10 % para Cd2+ e menor que 7 % para Pb2+. O método foi aplicado com sucesso para quatro diferentes amostras de biodiesel analisadas em triplicata. Pb2+ foi quantificado em três enquanto que Cd2+ somente foi encontrado duas das quatro amostras analisadas. O procedimento apresentou-se adequado para um nível de confiança de 95%.
44

Determinação de As, Cd, Pb e Zn por voltametria no médio curso do Rio Paraíba do Sul – Itatiaia – RJ

Costa, Julie Barnes de Souza 27 June 2017 (has links)
Submitted by Biblioteca de Pós-Graduação em Geoquímica BGQ (bgq@ndc.uff.br) on 2017-06-27T18:06:05Z No. of bitstreams: 1 Julie Barnes.pdf: 1285579 bytes, checksum: ed5b91554d525be7bf0e321b8384cea2 (MD5) / Made available in DSpace on 2017-06-27T18:06:05Z (GMT). No. of bitstreams: 1 Julie Barnes.pdf: 1285579 bytes, checksum: ed5b91554d525be7bf0e321b8384cea2 (MD5) / Universidade Federal Fluminense. Instituto de Química. Programa de Pós-Graduação em Geoquímica, Niterói, RJ / Os elementos traços, As, Cd, Pb e Zn ocorrem na natureza em uma variedade de formas químicas, incluindo espécies or gânicas e inorgânicas. São oriundos tanto de fontes naturais quanto antrópicas . Em decorrência do risco de intoxicação crônica desses elementos, os limites má ximos permitidos para esses elementos em água vêm diminuindo ao longo dos anos de acordo com a Organização Mundial de Saúde e pela Resolução 357/2 005 do CONAMA. Atualmente, as concentrações máximas permitidas par a águas superficiais são de 10 μg.L -1 , 1 μg.L -1 , 10 μg.L -1 e 180 μg.L -1 para As, Cd, Pb e Zn respectivamente (Resolução 357/2005 CONAMA). Este trabalho teve com o objetivos aplicar e validar um método eletro analítico empregando a voltametria de redissolução para determinação da concentração de As, Cd, Pb e Zn em águas fluviais no médio curso do rio Paraíba do Sul, na região da Usina Hidrelétr ica do Funil em Itatiaia – RJ, assim como o de verificar a influencia da barragem da represa na variação da concentração dos elementos. O método voltamétrico d esenvolvido apresentou sensibilidade e seletividade adequada, alcançando b aixos limites de detecção: 0,002 μg.L -1 de As, 0,002 μg.L -1 de Cd, 0,006 μg.L -1 de Pb e 0,095 μg.L -1 de Zn. Os resultados obtidos demonstraram a possível influenc ia da barragem, atuando como barreira geoquímica, acumulando elementos como As, Cd e Pb em sua represa. Quando comparados aos máximos permitidos pelos órgã os governamentais forma significativamente inferiores para o As, Pb e Zn, e superiores para Cd, possivelmente justificado pela constituição rochosa alcalina da região / The trace elements, As Cd Pb and Zn occur in nature in a variety of chemical forms, including organic and inorganic spe cies. They come from natural sources and anthropogenic activities. Because of th e risk of chronic poisoning of these elements, the maximum values allowed for them in water have decreased over years according to the World Health Organization an d CONAMA Resolution 357/2005. Currently, the maximum permissible concen trations for dinking water are 10 μg.L -1 , 1 μg.L -1 , 10 μg.L -1 e 180 μg.L -1 for As, Cd, Pb and Zn respectively (resolution 357/CONOMA 2005). This study aimed to d evelop and validate an analytical method using the Stripping Voltammetry f or determining the concentrations of As, Cd, Pb and Zn in water sample s from the middle course of Paraíba do Sul river, at the Hydroelectric of Funil – Itatiaia – RJ, and check the influence of the dam’s reservoir on water concentra tions of these elements. The developed voltammetric method showed adequate sensi tivity and selectivity, with low limits of detection: 0,002 μg.L -1 for As, 0,002 μg.L -1 for Cd, 0,006 μg.L -1 for Pb and 0,095 μg.L -1 for Zn. The results demonstrate the possible influ ence of the dam, acting as a geochemical barrier, accumulating As, Cd and P b. When compared to the maximum allowed by CONAMA this study found concentr ations significantly lower for As, Pb and Zn and higher for Cd.
45

Microfluidic graphenised-paper electroanalytical devices (μGPED) for adsorptive cathodic stripping voltammetric detection of metal contaminants

Pokpas, Keagan William January 2017 (has links)
Philosophiae Doctor - PhD / The need for clean, non-toxic drinking water supplies, free of pollutants and metal contamination is vital in impoverished areas and the developing world alike. With this in mind, the development of accurate, inexpensive, portable and simple devices for remote sensing applications is therefore pivotal for early detection and the prevention of illnesses. Over the last two decades, adsorptive stripping voltammetry (AdSV) has emerged as a superior detection method over common analytical techniques due to its low-cost instrumentation, unskilled labour and ability to detect a wide range of analytes. / 2020-08-31
46

Determinação sequencial de cromo, tálio, cádmio,chumbo, cobre e antimônio em concentrado polieletrolítico para hemodiálise por voltametria de redissolução através de um gradiente de pH / Sequential determination of chromium, thallium, cadmium, lead, copper and antimony in salinec hemodialysis concentrates by stripping voltammetry using electrolyte pH gradient

Schneider, Alexandre Batista 05 February 2010 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The sequential voltammetric determination of chromium, thallium, cadmium, lead, copper and antimony, present as contaminants in dialysate concentrates (CPHD), is presented herein. These concentrates contain a very high chloride concentration (ca. 3.8 mol L-1), which makes difficult the direct analysis, without pretreatment, by many analytical techniques, like atomic absorption spectrometry and chromatography. The experimental conditions were varied in order to improve the peak resolution, selectively and sensitivity. The method is based on the gradual decrease on the pH of the solution present in the voltammetric cell, so that, the sequential determination of the analytes was possible. At pH 6 6.2, Cr determination was carried out with DTPA by catalytic adsorptive stripping voltammetry (CAdSV). Afterwards, the pH was adjusted at 4.8 ± 0.2 to determine thallium by anodic stripping voltammetry (ASV). At this pH, DTPA is non interfering specie for Tl-determination and, additionally, it masks the main interfering species for thallium (lead and cadmium). Cadmium, lead and copper were assayed by ASV after setting the pH to 1.5 ± 0.5. Under these conditions, DTPA releases these three metallic species from the previously built complexes, so that they behave as free species to react on the HMDE-surface. By setting with HCl the pH to values around zero antimony was assayed by ASV. At this acidity and in presence of high chloride concentrations antimony can be assayed with high sensitivity. The method was used for analysis of commercial samples of CPHDs and the found concentration varied from < LD until 140 Ug L-1. / A Determinação sequencial de cromo, tálio, cádmio, chumbo e cobre e antimônio em concentrado polieletrolítico para hemodiálise (CPHD) é descrita. Estes concentrados contêm uma concentração extremamente alta de íons cloreto (cerca de 3,8 mol L-1), o que torna difícil a análise direta por muitas técnicas analíticas. As condições experimentais foram variadas a fim de aumentar a resolução de pico, seletividade e sensibilidade. O método é baseado no decréscimo gradual do pH da solução presente na célula voltamétrica, o que possibilitou a determinação sequencial dos analitos. Em pH 6 6,2, a determinação de Cr foi realizada com DTPA por voltametria catalítico-adsortiva de redissolução (CAdSV). Em seguida, o pH foi ajustado para 4,8 ± 0,2 para determinar Tl por voltametria de redissolução anódica (ASV). Neste pH, DTPA não é uma espécie interferente na determinação de Tl e, adicionalmente, ele mascara as principais espécies interferentes para tálio (chumbo e cádmio). Cádmio, chumbo e cobre foram determinados por ASV após ajuste do pH a 1,5 ± 0,5. Sob estas condições, estas três espécies são liberadas em solução a partir dos complexos com DTPA previamente formados, de modo que elas se comportam como espécies livres para reagir na superfície do HMDE. Diminuindo-se o pH da solução para < 0 com HCl, foi determinado antimônio por ASV. Nesta acidez e na presença de uma alta concentração de cloretos, Sb pode ser medido com uma alta sensibilidade. O método foi utilizado para a análise de amostras de CPHD comerciais e as concentrações encontradas dos analitos variaram de < LD até 140 Ug L-1.
47

Nanocomposite-graphene based platform for heavy metal detection

Willemse, Chandre Monique January 2010 (has links)
Magister Scientiae - MSc (Dept. of Chemistry) / This study reports the synthesis of graphene by oxidizing graphite to graphite oxide using H2SO4 and KMnO4 and reducing graphene oxide to graphene by using NaBH4. Graphene was then characterized using FT-IR, TEM, AFM, XRD, Raman spectroscopy and solid state NMR. Nafion-Graphene in combination with a mercury film electrode, bismuth film electrode and antimony film electrode was used as a sensing platform for trace metal analysis in 0.1 M acetate buffer (pH 4.6) at 120 s deposition time, using square-wave anodic stripping voltammetry (SWASV). Detection limits were calculated using 3σblank/slope. For practical applications recovery studies was done by spiking test samples with known concentrations of metal ions and comparing the results to inductively coupled plasma mass spectrometry (ICPMS). This was then followed by real sample analyses. / South Africa
48

Voltametrické stanovení chloramfenikolu a chlorambucilu na amalgámových elektrodách / Voltammetric Determination of Chloramphenicol and Chlorambucil on Amalgam Electrodes

Havlíková, Štěpánka January 2015 (has links)
This diploma thesis is focused on the determination of chloramphenicol by differential pulse voltammetry (DPV), DC voltammetry (DCV), cyclic voltammetry (CV) and adsorptive stripping voltammetry (AdSV) on a meniscus modified silver solid amalgame electrode (m- AgSAE). For the determination of chloramphenicol the optimum conditions were found and under these conditions concentration dependences were measured and then limits of quantification were determined. The influence of pH of BR buffer was tested. For determination of chloramphenicol by DCV pH 7 was chosen as an optimum background and pH 8 was chosen as an optimmum for DPV determination. Under these conditions linear dependences were obtained in the concentration range of 1·10-6 - 1·10-4 mol·l-1 . The limit of detection of chloramphenicol by DCV was 2.3·10-6 mol·l-1 . The limit of detection of chloramphenicol by DPV was 2.1·10-6 mol·l-1 in distilled water, 2.9·10-6 mol·l-1 in river water and 4.2·10-6 mol·l-1 in drinking water. Electrochemical behavior of chloramphenicol was studied by cyclic voltammetry in BR buffer with pH 2, 6, 8, 12 and then mechanism of reduction of chloramphenicol was propose based on available literature. Chloramphenicol was determined in drug Spersadex by DPV in BR buffer with pH 8. The optimal conditions for determining...
49

Elektrochemické stanovení Fomesafenu / Electrochemical Determination of Fomesafen

Maška, Jan January 2013 (has links)
The submitted work deals with the application of voltammetric determination of Fomesafen using non-traditional mercury meniscus modified silver solid amalgam electrode on model samples of Fomesafen in real aqueous matrices of drinking and river water. This method of measurement has been developed and optimized in my bachelor thesis, which the diploma thesis is related to. Fomesafen belongs to a group of herbicides used on a mass scale in the late 20th century in the USA and in many countries around the world still used even today. Among its side effects according to the EPA include, among others, potential carcinogenicity to humans and confirmed carcinogenicity to some mammals (such as rats) which led to a legislative regulation on its use in many countries around the world including the USA, the European Union and many others. Silver solid amalgam electrode has been developed with the intention to limit the use of mercury in accordance with new legislation of the European Union and the concept of green analytical chemistry. Despite the low levels of mercury mainly bound in the form of virtually harmless silver amalgam electrode retains very similar electrochemical properties with proven mercury electrodes. As part of the thesis, direct determination of a number of partial extraction of Fomesafen...
50

Determinação simultânea de Cu(II), Pb(II), Cd(II) e Zn(II) em águas e sedimentos usando análise por injeção sequencial (SIA) com detecção voltamétrica / Simultaneous determination of Cu(II), Pb(II), Cd(II) and Zn(II) in waters and sediments using sequential injection analysis (SIA) with voltammetric

Ribeiro, Luiz Fernando 29 August 2014 (has links)
Esta dissertação descreve o desenvolvimento de uma metodologia de determinação de Cu(II), Pb(II), Cd(II) e Zn(II) em amostras ambientais por voltametria de redissolução anódica (ASV) automatizada com sistema de Análise por Injeção Sequencial (SIA). Sensores impressos com o eletrodo de trabalho de filme fino de mercúrio foram utilizados em uma cela de fluxo. As determinações foram feitas por adição de padrão, com o sistema SIA fazendo a diluição em linha da solução padrão de referência e formando na bobina coletora e auxiliar um segmento contendo as zonas de amostra, solução padrão e solução de diluição. A concentração do padrão preparada nesse segmento gerou um sinal de corrente indistinguível do sinal gerado por uma solução padrão de mesma concentração preparada em batelada em balão volumétrico. Os limites de quantificação e detecção foram da ordem de &#181;g L-1, comparáveis à de técnicas de espectrometria atômica com detecção óptica, cujos custos instrumentais e de manutenção são significativamente maiores. Com o sistema proposto os limites de quantificação e detecção podem ser aumentados ou diminuídos pela simples alteração dos parâmetros como vazão e número de reversões de fluxo, bem como o tempo de deposição no potenciostato. Os limites de detecção e quantificação foram, respectivamente, de 1,3 e 4,3 &#181;g L-1 para o Cu(II), 1,4 e 4,6 &#181;g L-1 para o Pb(II), 0,6 e 1,8 &#181;g L-1 para o Cd(II) e 4,2 e 14 &#181;g L-1 para o Zn(II). Esses limites de detecção e quantificação foram obtidos quando o método funcionou com volume de amostra de 1000 &#181;L, vazão de 10 &#181;L s-1 (durante a etapa de deposição), e utilizando 3 reversões de fluxo (volume de reversão = 950 &#181;L), totalizando um tempo de deposição de 315 segundos. O potenciostato, trabalhando sincronicamente com o sistema SIA operou com potencial de condicionamento de -0,1 V vs. pseudo referência de Ag (100 s), potencial de deposição de -1,0 V para Cu(II), Pb(II) e Cd(II) e de -1,3 V para Zn(II) (315 s), frequência de onda quadrada de 100 Hz, incremento de potencial de 6 mV e altura de pulso de 40 mV. Para determinação de Zn(II) foi necessário depositar Ga0 no eletrodo de trabalho e evitar a formação do intermetálico de Zn0 com Cu0. Estudos de interferentes não apontaram desvios significativos em interferentes aniônicos e catiônicos, mas apresentaram desvios significativos na presença de ácidos húmicos e ácidos fúlvicos. A exatidão do método foi avaliada por estudos de adição e recuperação em amostra de água que resultaram taxas de recuperação próximas de 100%. A exatidão também foi avaliada pelas porcentagens de recuperação das concentrações dos metais da amostra certificada de sedimento CRM-701 submetido ao processo de extração sequencial BCR®. As concentrações obtidas foram testadas pelo teste t de Student, mostrando que os desvios dos valores obtidos em relação aos valores certificados não sugerem a existência de diferenças estatísitcamente significativas. / This dissertation describes the development of a methodology for determination of Cu(II), Pb(II), Cd(II) and Zn(II) in environmental samples by anodic stripping voltammetry (ASV) automated by Sequential Injection Analysis (SIA). Screen printed thin mercury film sensors were used as working electrode in a flow cell. The determinations were made by standard addition, with the SIA system performing the inline dilution of the reference standard solution and forming a segment inside the holding coil containing zones of sample, standard and dilution solutions. The concentration of the standard prepared in this segment generated a current signal undistinguishable from the signal generated by a standard solution of the same concentration prepared manually in a volumetric flask. The limits of quantification and detection were at the level of &#181;g L-1, comparable to those of atomic spectrometry techniques with optic detection, whose instrumental and maintenance costs are significantly higher. With the proposed system the limits of quantification and detection can be increased or lowered by simple change of parameters such as flow rate and number of flow reversals, as well as the deposition time at the potenciostat. The limits of detection and quantification were, respectively, 1.3 and 4.3 &#181;g L-1 for Cu(II), 1.4 and 4.6 &#181;g L-1 for Pb(II), 0.6 and 1.8 &#181;g L-1 for Cd(II) and 4.2 and 14 &#181;g L-1 for Zn(II). These limits of detection and quantification were obtained for a sample volume of 1000 &#181;L, flow rate of 10 &#181;L s-1 (during the deposition step), and utilizing 3 flow reversals (volume of reversion = 950 &#181;L) totalizing a deposition time of 315 seconds. The potentiostat worked synchronically with the SIA system performing a conditioning potential of -0,1 V vs pseudo reference of Ag (100 s), deposition potential of -1,0 V for Cu(II), Pb(II) and Cd(II) or -1,3 V for Zn(II) (315 s), square wave frequency of 100 Hz, potential step of 6 mV and pulse height of 40 mV. For determination of Zn(II), deposition of Ga0 on the working electrode was necessary to avoid the formation of intermetallic between Zn0 and Cu0. Studies of interference did not point significant deviation for anionic and ionic potentially interfering substances, but exhibited significant deviations in the presence of humic and fulvic acids. The accuracy of the method was assessed by spike and recovery experiments in a water sample that resulted recovery rates near of 100%. The accuracy was also assessed by percentages of recovery of concentrations of metals in the certified sediment sample CRM-701 undergoing the sequential extraction procedure of BCR®. The concentrations obtained were tested by test t of Student, showing that the deviations of the obtained values don´t suggest the occurrence of statistically significant differences