• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 132
  • 8
  • 8
  • 8
  • 8
  • 7
  • 2
  • 1
  • 1
  • Tagged with
  • 136
  • 67
  • 35
  • 30
  • 30
  • 25
  • 23
  • 22
  • 19
  • 18
  • 17
  • 17
  • 16
  • 16
  • 16
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Estudo comparativo entre sistema de aspiração fechado e sistema de aspiração aberto em recém-nascidos mantidos em ventilação mecânica convencional invasiva / Comparative study between the open suction system and the closed suction system in newborn kept in invasive conventional mechanical ventilation

Lúcia Cândida Soares de Paula 11 August 2009 (has links)
A ventilação mecânica invasiva é um recurso importante no tratamento dos recém-nascidos internados com vários distúrbios nas Unidades de Cuidados Intensivos Neonatais, no entanto, este tratamento está associado a várias complicações, sendo a principal, o impedimento do paciente para eliminar suas próprias secreções pulmonares. Desta forma a aspiração endotraqueal é um procedimento fisioterapêutico essencial para desobstruir as vias aéreas, mais além de seus efeitos benéficos, citam-se também alguns adversos. O objetivo deste estudo foi quantificar e comparar as variações da saturação de oxigênio, e a presença de alterações hemodinâmicas, de freqüência cardíaca e de pressão artéria média durante todo o processo de aspiração (antes, durante e após o procedimento), utilizando dois tipos de sistema de aspiração: aberto (SAA) e fechado (SAF). Foi realizado um estudo prospectivo randomizado e controlado com 39 recém nascidos com idade gestacional a 34 semanas em uso de ventilação mecânica em aparelhos com fluxo continuo, limitados a pressão e ciclados a tempo. Os RN foram classificados em dois grupos conforme os parâmetros ventilatórios: O Grupo I foi ventilado utilizando PEEP a 5 cmH2O e MAP a 8 cmH2O e o Grupo II PEEP < de 5 cmH2O e MAP < de 8 cmH2O. Foram excluídos os pacientes com malformações cardíacas comprovadas pela ecocardiografia, malformações pulmonares, pneumotórax hipertensivo, atelectasias extensas, no mínimo em um lobo pulmonar, e hipertensão pulmonar persistente neonatal (HPPN), utilização de óxido nítrico (NO) ou de ventilação de alta freqüência (VAF). As aspirações endotraqueais com o xv SAA e o SAF foram realizadas alternadamente no mesmo paciente de acordo com os seguintes critérios: diminuição de saturação de oxigênio abaixo de 89%, desconforto respiratório; ausculta pulmonar e/ou agitação. O procedimento foi avaliado em sete momentos diferentes: Antes de posicionar o RN para a aspiração (Ta), imediatamente antes da aspiração (Tb), depois das duas aspirações (Tc1 e Tc2), após 5 minutos do procedimento (Td), após 10 minutos do procedimento (Te). A análise dos resultados da associação entre os dois grupos (Grupo I e Grupo II) com cada uma das variáveis qualitativas foi realizada pelo do teste Qui-Quadrado e quando este não se mostrou adequado foi utilizado o Teste Exato de Fisher. A comparação entre os dois grupos para as variáveis quantitativas foi realizada através do teste de Mann-Whitney, sendo considerado diferença significante p < 0,05. Na população estudada não se encontraram diferenças estatisticamente significantes entre as variáveis estudadas (saturação de oxigênio, pressão arterial média e freqüência cardíaca) quando comparados os dois sistemas de aspiração, aberto e fechado em nenhum dos dois grupos. Portanto, é possível concluir que ambos os sistemas de aspiração endotraqueal podem ser utilizados sem nenhuma desvantagem para o SAA em relação ao SAF, desde que a casuística seja semelhante à do estudo apresentado / Comparative study between the open suction system and the closed suction system in newborn kept in invasive conventional mechanical ventilation The invasive mechanical ventilation is an important resource in the treatment of the newborn admitted with different illnesses in the Neonatal Intensive Care Units, however, such treatment is associated with several complications. The main complication is that it prevents the patients to eliminate his own pulmonary secretions. Therefore the intratracheal suction is an essential physiotherapeutic procedure to clear the airways, but besides its positive effects, it has also some negative effects. The objective of this study was to quantify and compare the variations of the oxygen saturation and the presence of hemodynamic, heart rate and average blood pressure alterations during the whole suction procedure (before, during and after the procedure), using two types of suction systems: open (OSS) and closed (CSS). A controlled random prospective study was carried out with 39 newborn with gestational ages to 34 weeks using mechanical ventilation devices with a continuous flow, limited to pressure and cycled in time. The NB were classified in two groups according to the ventilatory parameters. Group I was ventilated using PEEP to 5 cmH2O and MAP to 8 cmH2O and group II PEEP < of 5 cmH2O e MAP < of 8 cmH2O. The patients with heart malformation proven by the echocardiography, lung malformation, tension pneumothorax, extensive atelectasies, at least in one pulmonary lobe, and persistent pulmonary hypertension of the newborn (PPHN), utilization of nitric oxide (NO) or of high frequency ventilation (HFV). The intratracheal suctions with OSS and CSS were alternately carried out on the same patient
112

Avaliação da coordenação sucção/deglutição/respiração através da ausculta cervical digital em recém-nascidos pré-termo e a termo

Silva, Caroline Silveira da January 2013 (has links)
Introdução: Recém- nascidos a termo nascem com a habilidade de coordenar as funções de sucção- deglutição- respiração. Recém-nascidos pré-termo não apresentam essa habilidade, consequentemente, necessitam de alimentação por sonda e podem apresentar dificuldade na transição da alimentação por sonda para via oral. O objetivo desse estudo foi comparar o padrão de coordenação sucção-deglutição-respiração de recém-nascidos a termo em aleitamento materno exclusivo e recém-nascidos pré-termo na transição da alimentação por sonda para a via oral com mamadeira. Métodos: Foram avaliados 64 recém-nascidos (32 recém-nascidos pré-termo e 32 recém-nascidos a termo) internados na UTI Neonatal e Alojamento Conjunto do Hospital Fêmina de Porto Alegre. Os recém-nascidos a termo foram avaliados durante as primeiras 48horas de vida e os recém-nascidos pré-termo foram avaliados no início da alimentação por via oral após período de alimentação por sonda orogástrica. O equipamento utilizado na ausculta cervical digital era composto por um detector acústico e por um pré-amplificador com filtro conectados a um computador Coreo 2 Duo. O microfone foi fixado com fita adesiva no pescoço do recém-nascido para captar os sinais da sucção/deglutição durante a alimentação. Três sinais de 30 segundos foram obtidos de cada RN e uma média foi obtida para os seguintes parâmetros: total de “suck-swallow signal” (SSS); duração total dos SSS; total de pausas para respirar >2,5 segundos; duração total das pausas. Os dados dos sinais dos sons da deglutição gravados foram analisados visual e auditivamente pelo Software Raven versão 1.1 Resultados: Os resultados mostraram que houve diferença estatisticamente significante para o parâmetro “duração total dos SSS”, mostrando que o tempo envolvido na sucção/deglutição é maior para os recém-nascidos pré-termo. Em relação ao parâmetro “duração total das pausas”, observou-se um tempo maior para os recém-nascidos a termo. O parâmetro “número de pausas” que indica a quantidade de momentos que o recém-nascido apresenta pausa para respirar durante a mamada no período de gravação também foi significativamente maior para os recém-nascidos a termo em comparação aos recém-nascidos pré-termo. Conclusão: Demonstramos que a ausculta cervical digital é um exame de fácil execução e minimamente invasivo na avaliação da coordenação sucção-deglutição-respiração em recém-nascidos a termo e pré-termo. Os recém-nascidos a termo com aleitamento materno durante os primeiros dias de vida apresentaram pausas para respirar mais prolongadas durante o processo de sucção-deglutiçãorespiração em comparação aos recém-nascidos pré-termo. Isso pode refletir o estágio do desenvolvimento do padrão de maturidade de processo de deglutição. / Background: Fullterm newborn are born with the ability to coordinate the functions of sucking, swallowing and breathing. Preterm infants may not have this ability, therefore, may require tube feeding and may have difficulty in the transition from tube feeding to oral feeding. The aim of this study was to compare the coordination pattern of suck, swallow and breathing in fullterm newborn exclusively breastfed and preterm newborn at the transition from tube feeding to oral bottle feeding . Methods: 64 newborn (32 preterm and 32 fullterm) admitted to the Neonatal Intensive Care Unit and Rooming-in of Femina Hospital of Porto Alegre. Fullterms were evaluated during the first 48 hours of life and preterms were assessed at the beginning of oral feeding after feeding period by orogastric tube. The equipment used in digital cervical auscultation included an acoustic detector and a preamplifier with filter connected to a computer 2 Duo Core. The microphone was fixed with tape on the neck of the newborn to capture the signals of suck / swallow during feeding. Three signals of 30 seconds were obtained from each newborn and an average was obtained for the following parameters: total number of "suck-swallow signal" (SSS); total duration of the SSS; total number of pauses> 2.5 seconds and total duration of pauses and . Signs of swallowing sounds recorded were analyzed visually and audibly by Raven Software version 1.1 Results: The results showed statistically significant differences for the parameter "total duration of the SSS," showing that the time involved in suction / swallowing is greater for preterms. As for the parameter "total duration of pauses," there was more time spent by fullterms. The parameter "number of pauses" that indicates the amount of times that newborn have respiratory pause during feeding in the recording period was also significantly higher for fullterms when compared with preterms. Conclusion: We demonstrated that digital cervical auscultation is a minimally invasive, feasible, and easy-to-perfom tool for evaluation of suck-swallowbreathing coordination in newborn. The fullterm infants with breastfeeding within the first days of life had prolonged respiratory pauses during the process of sucking, swallowing and breathing compared to preterms. This may reflect the stage of development of the natural maturity process of swallowing.
113

OS EFEITOS DA INTERVENÇÃO FONOAUDIOLÓGICA SENSÓRIO-MOTORA ORAL SOBRE A SUCÇÃO NÃO-NUTRITIVA EM RECÉM-NASCIDOS PRÉ-TERMO / THE EFFECTS OF THE ORAL MOTOR SENSORIAL INTERVENTION IN NON-NUTRITIVE SUCKING IN PRE-TERM INFANTS

Carnetti, Mara Gislaine 16 March 2005 (has links)
The speech-language pathology intervention in newborn infants with oral motor system problems during their admission in the neonatal intensive care unit (NICU) can helps not only the oral motor development, but also their global development, minimizing future language problems. The aim of this study was to determine if the oral motor sensorial system intervention influences or modifies non-nutritive sucking (SNN) of preterm infants (RNPT) admitted in the NICU of the University Hospital of Santa Maria. A total of 20 RNPT were enrolled in this study subdivided into an experimental group (GE) and a control group (GC), with 10 infants in each group. Inclusion criteria were preterm babies clinically stable at the moment of their transition from tube to bottle feeds, without alterations in their defense reflections (cough, bite fasic and gag) and after written informed consent was obtained from parents and/or legal representation. Exclusion criteria included preterm infants with congenital malformation of head and neck, genetic syndrome, intracranial hemorrhage, perinatal asphyxia and bilirubin encephalopathy and/or kernicterus. Both groups were submitted to fonoaudiological evaluation and re-evaluation based in Hernandez (2001) and were observed: the behavior state (EC), oral reflections, reactions of the stimulus and same aspects of non-nutritive suking like force, number of sucking in the first three burst and the time of pauses among the sucking bursts. The GE received twice a day oral motor sensorial system stimulation, embodied the stimulation extra motor-sensorial and intra-oral, being that, after the conclusion of the same one, the specific proceeding were indicted in the protocol that went along with each RN, this protocol was based in Medeiros et al. (2003). When comparing groups GE and GC, we noticed that the oral motor sensorial system intervention was good in order to provide a better organization in the sucking standard of the RNs that were stimulated. When comparing the obtained results in the valuation and re-valuation of the stimulated group relating to the SNN, we found out that there was not difference statistically significant, meantime, it was observed that, when talking about the number of sucking, there was a decrease in the valuation bursts and in the re-valuation, as well, and in this last one, the numbers were closer, and it indicate that the stimulation work might help in the organization of the RN in order to keep a sucking standard with closer indexes. According to the time of pauses, it was noticed that the value of the p was higher than 0,05, however it was noticed the considerable difference in the second time of the pause, that suggests that with the oral motor sensorial system stimulation program the RN organized the time of the pauses among the sucking, providing a better synchronization among the bursts of sucking, though there was a decrease in the valuation and re-valuation, this way it was observed a higher approach in the valuation, different to the obtained results in the group that received stimulation. When talking about the time of the pauses, it was noticed that the value of p was higher that 0,05, however it was also observed a considerable difference of the valuation and re-valuation, and the higher values in this last one, it suggests that the RN had more fatigue comparing to the GE. About the time of confining, comparing the groups, there was not difference statistically significant, it showed that the oral motor-sensorial stimulation program did not accelerated the process of hospital discharge. / O trabalho fonoaudiológico hospitalar na assistência aos bebês com alterações no sistema sensóriomotor oral (SSMO) propicia não só o desenvolvimento motor oral como também o desenvolvimento global minimizando assim futuras alterações na linguagem do recém-nascido (RN). Este trabalho teve por objetivo verificar os efeitos da intervenção fonoaudiológica na sucção não-nutritiva (SNN) em recém-nascidos pré-termo (RNPT), da UTI neonatal do Hospital Universitário de Santa Maria (HUSM-UFSM). O grupo de estudo foi composto por 20 RNPT subdivididos em grupo experimental (GE) e grupo controle (GC), com 10 RN em cada grupo. Foram incluídos RN clinicamente estáveis, com indicação para início de via oral, que não apresentassem alterações que pudessem interferir no desempenho das funções orais, que não apresentassem ausência dos reflexos de defesa (tosse, mordida fásica e gag) durante a avaliação ou intervenção fonoaudiológica, bem como aqueles cujos pais e/ou representantes legais deram seu consentimento livre e esclarecido. Foram excluídos RN com malformações congênitas de cabeça e pescoço, síndromes genéticas, hemorragias intracranianas diagnosticadas por ultrassonografia de crânio, asfixia peri-natal e encefalopatia hiperbilirrubínica diagnosticada pela equipe médica através da presença de sinais clínicos como hipotonia ou hipertonia e convulsões. Os grupos GE e GC foram submetidos à avaliação e à reavaliação fonoaudiológica, sendo que o GE recebeu estimulação fonoaudiológica diariamente. A avaliação e a reavaliação fonoaudiológica foram realizadas a partir da elaboração de um protocolo baseado em Hernandez (2001), em que foi observado o estado comportamental (EC), realizada pesquisa dos reflexos orais, reação ao estímulo e avaliação da SNN, englobando aspectos relacionados à força, ao número de sucções nos primeiros três blocos e ao tempo de pausa entre os blocos de sucções. A intervenção fonoaudiológica englobou a estimulação sensório-motora extra e intra-oral, sendo que após o término da mesma os procedimentos específicos foram referenciados no protocolo de acompanhamento de cada RN, o qual foi baseado em Medeiros et al. (2003). Na comparação entre os grupos GE e GC verificou-se que a intervenção fonoaudiológica foi benéfica no sentido de propiciar uma melhor organização no padrão de sucção dos RN estimulados. Ao comparar os resultados obtidos na avaliação e na reavaliação do grupo estimulado referentes à SNN, constatou-se que não houve diferença estatisticamente significante, observando-se, entretanto, que, quanto ao número de sucções, houve um decréscimo nos blocos tanto na avaliação como na reavaliação, sendo que nesta última os números ficaram mais próximos, indicando que o trabalho de estimulação possa ter auxiliado na organização dos RN em manter um padrão de sucção com índices mais aproximados. Em relação ao tempo de pausa, verificou-se que o valor do p foi maior que 0,05, porém observou-se considerável diferença no segundo tempo de pausa, sugerindo que com o programa de estimulação fonoaudiológica os RN organizaram o tempo de pausa entre as sucções, proporcionando uma melhor sincronia entre os blocos de sucções. Ao comparar os resultados obtidos na avaliação e na reavaliação do grupo controle concernentes à SNN, verificouse que não houve diferença estatisticamente significante em relação ao número de sucções, todavia houve um decréscimo na avaliação e na reavaliação, sendo que se observou uma maior aproximação na avaliação, diferente dos resultados obtidos no grupo que recebeu estimulação. Quanto ao tempo de pausa, constatou-se que o valor do p foi maior que 0,05, entretanto observou-se uma considerável diferença da avaliação para a reavaliação, sendo os valores maiores nesta última, sugerindo que estes RN tenham fatigado mais em comparação aos do GE. Quanto ao tempo de internação, na comparação entre os grupos não se observou diferença estatisticamente significante, demonstrando que o programa de estimulação sensório-motora oral não acelerou o processo de alta hospitalar.
114

Estudo do colapso do solo através de ensaios de placa monitorados com tensiômetros e tomografia computadorizada / Study of soil collapse through plate tests monitored with tensiometers and computerized tomography

Wilson Conciani 28 April 1997 (has links)
Esta tese apresenta um estudo de solos colapsíveis utilizando provas de carga em placas executados com inundação da cava. Durante o ensaio a sucção foi monitorada com tensiômetros instalados em cinco profundidades distintas. A inundação da cava foi também monitorada pelo uso da técnica de reflectometria no domínio do tempo. Desta forma pode-se acompanhar a evolução da frente de infiltração e da sucção durante todas as fases do ensaio. Foi introduzido também o uso da tomografia computadorizada para registrar as alterações causadas no solo pelo carregamento e posterior inundação. O acompanhamento da frente de infiltração durante o ensaio foi importante para conhecer a profundidade de influência do colapso no maciço do solo. De posse dos valores de sucção, foi possível a utilização de modelos para solo não saturado para verificar a sua aplicabilidade na previsão de comportamento de estruturas de fundação. A tomografia computadorizada forneceu informações a respeito da distribuição de massa específica do solo antes e depois do carregamento, permitindo concluir que a região mais afetada pelo colapso se restringe a 0,25 D. / This thesis presents a soil collapse study using plate load tests performed with soaking the test pit. During the test suction was monitored by tensiometers embedded at five different depths. Thus, it was possible to follow the wetting front and suction evolution all over the tests stages. lt was also introduced the computerized tomography technique to record the soil changing caused by loading and wetting. Monitoring the wetting front during the test was important to know the influence depth of collapse at soil mass. Having the suction values it was possible to use behaviour models of unsaturated soils to verity their applicability on predicting foundations structure settlements. The computerized tomography yields informations about soil unit weight distribution before and after loading, allowing concludes that collapse most affected region is restrained up to 0.25 D.
115

Atrito lateral e resistência de base em tubulões a céu aberto em solos colapsíveis / Skin friction and base resistance of large diameter bored piles in collapsible soils

Túlia Ribeiro da Silva Santos 13 June 2001 (has links)
Este trabalho apresenta resultados de provas de carga em tubulões a céu aberto, com o monitoramento do teor de umidade através do processo de tradagem, a cada metro, até uma profundidade de 9,0 m, em um maciço de solo não-saturado e colapsível, representativo da região centro-oeste do interior do Estado de São Paulo. Ao todo, realizaram-se dez provas de carga, no Campo Experimental de Fundações da EESC/USP, com e sem inundação do terreno, com carregamento do fuste, foram introduzidas placas de isopor (E.P.S) a fim de, durante a realização dos ensaios, obter separadamente as parcelas de resistência de base e por atrito lateral. A partir dos dados obtidos, procedeu-se uma análise da influência da pressão de sucção, da inundação do terreno e do intervalo de tempo entre a escavação e os outros dois, concretados logo após a etapa de escavação. Observou-se que a sucção tem um efeito importante no comportamento dos tubulões a céu aberto: com o aumento da sucção maiores se tornam as resistências de base e por atrito lateral. Consequentemente, a influência do colapso apresenta-se mais significativa com o aumento da pressão de sucção. / This work presents results of static load tests, in large diameter bored piles, with measurements of soil moisture content in an unsatured collapsible soil, considered as representative of the middle - west region of the State of São Paulo, Brazil. Ten load tests were performed at Foundation Experimental Field of the EESC/USP, with and without wetting of the pit and the with quick maintained load (QML). In the large diameter bored piles were introduction, between the base and the shaft, an layer of \"isopor\", to separate the skin friction and the base resistance, during the static load tests. The gathered data allowed an assessment of the influence the soil suction, of the soil soaking and the effect between excavation and concrete in the behaviour these isolate elements of foundation.
116

Influência da dimensão e da sucção matricial no comportamento de fundações superficiais assentes em solo arenoso não-saturado / Size and matric influence in the behavior of shallow foundations in unsaturated sandy soils

Ana Paula Fontana Vianna 08 June 2005 (has links)
Analisa-se a influência da sucção matricial e da dimensão de sapatas na capacidade de carga e nos recalques de fundações rasas, assentes em areia não-saturada. Na primeira parte da pesquisa foram analisadas 14 provas de carga estática em placas metálicas rígidas assentes a 1,5 m de profundidade, com diâmetros de 0,20, 0,40 e 0,80m e em uma sapata circular de concreto com diâmetro de 1,50 m, no campo experimental de fundações da USP/São Carlos. Devido ao caráter colapsível do solo, a sucção matricial foi monitorada por meio de tensiômetros instalados no fundo da cava. Na segunda parte da pesquisa, foram realizados ensaios em centrífuga, na Universidade do Colorado em Boulder, utilizando-se placas metálicas de 30 mm, 50 mm e 100 mm, ensaiadas a 1 g, 5 g, 10 g, 15 g, 25 g, 50 g e 100 g. As placas foram assentes em maciço de areia em três condições de umidade: seca, inundada e não-inundada. A partir dos resultados obtidos, procedeu-se a análise da capacidade de carga levando-se em conta tanto o efeito da dimensão como o da sucção matricial. A influência da dimensão nos recalques também foi analisada. Ratificou-se que o aumento da sução matricial provoca um aumento substancial na capacidade de carga do sistema placa-solo e uma diminuição considerável nos recalques. Em relação à influência da dimensão no comportamento de fundações rasas, demonstrou-se que tanto a variação da capacidade de carga como a dos recalques não ocorre de forma linear e crescente como apresentado pelos métodos teóricos. Para pequenas dimensões da sapata, os valores de capacidade de carga e recalque aumentam / The influence of matric suction and size of footings in the bearing capacity and settlement of shallow foundations in unsaturated sandy soils are analyzed. Fourteen plate load tests were performed in the first part of the research. Rigid metallic plates with diameters 0,20, 0,40, 0,80 m and one concrete circular footing with 1,50 m were used in the tests. All plates and footing were positioned at 1,50 m depth. The tests were performed in the foundation experimental field of USP/São Carlos. Due to the soil collapsible character, the tests were performed with the monitoring of matric suction pressure through tensiometers installed in the bottom of the holes. Centrifuge tests were carried out at the University of Colorado at Boulder in the second part of the research. Metallic plates with 30 mm, 50 mm and 10 mm were used and the gravity levels were 1 g, 5 g, 10 g, 15 g, 25 g, 50 g e 100 g. The plates were positioned on top of a sandy soil with three moisture conditions: dry, flooded and non-flooded. Thus, the capacity will be analyzed taking into consideration both the geometry of the tested plates and the influence of the matric suction pressure. The footing size influence in the settlement was also analyzed. A substantial increase of the plate-soil system bearing capacity and a considerable decrease in the settlements, caused by matric suction increase, was confirmed. It was also demonstrated that the bearing capacity and settlements variations are not a linearly increasing function of the size as theoretical methods suggest. For small footings, the bearing capacity and settlement increase as the footing size decreases
117

Caracterizações geotécnica e mineralógica de um filito dolomítico do Quadrilátero Ferrífero com vistas ao estudo de estabilidade de taludes incorporando a sucção / Geotechnical and mineralogic characterizations of a dolomitic phyllites from Iron Quadrangle (MG) aiming to study the slopes stability incorporating the suction

Soares, Ecidinéia Pinto 07 March 2008 (has links)
Made available in DSpace on 2015-03-26T12:34:04Z (GMT). No. of bitstreams: 1 01 - Capa_Abstract.pdf: 55603 bytes, checksum: 3a372969ed83a2d08c9602bc879b314d (MD5) Previous issue date: 2008-03-07 / Fundação de Amparo a Pesquisa do Estado de Minas Gerais / The present work presents the results of an extensive laboratory test study for the characterization of the behavior of a dolomitic phyllite under unsaturated conditions. This rock type is commonly found at Iron Quadrangle area, Brazil and is well known for its high anisotropy and weatherability. These properties impose a distinct behavior as sound rock changes to very to highly weathered materials in several months, with severe influence on its geotechnical properties. Eight undisturbed samples were collected in two open mine pits belonging to Vale (four at Pico mine and four at Capitão do Mato mine). Both mineralogical and geotechnical characterization of these material were done. Suction curves were determined through filter paper technique. Both unsaturated strength envelope and verification of suction curves were determined through empirical method. Resulting data was used into a slope stability study of a typical geological section from Pico mine, in order to evaluate its influence over safety. Use of other models and procedures is suggested to subsidy future discussion on risk analysis of open pit mining for this particular region. / Este trabalho apresenta os estudos desenvolvidos para a caracterização do filito dolomítico presente na região do Quadrilátero Ferrífero, Minas Gerais, Brasil, com o objetivo de investigar seu comportamento em taludes de mineração para a condição não saturada. O filito dolomítico se caracteriza pela sua elevada anisotropia, em função da presença de uma foliação bem marcada e pela também elevada alterabilidade que faz com que materiais classificados como sãos, passem, em alguns meses, a materiais muito a extremamente alterados, o que piora sobremaneira suas propriedades geotécnicas. Quando muito alterado é constituído por lentes de material argiloso e lentes de areia. A amostragem constou de oito blocos indeformados, sendo que quatro foram retirados da Mina do Pico, localizada em Itabirito/MG e quatro blocos da Mina Capitão do Mato, localizada em Nova Lima/MG, ambas pertencentes à Companhia Vale do Rio Doce. Foram realizados ensaios de caracterização geotécnica e mineralógica e determinação das curvas de sucção por meio da técnica do papel filtro. Para a determinação da envoltória de resistência não saturada e verificação das curvas de sucção foram utilizados modelos empíricos. A partir dos resultados obtidos foi analisada a estabilidade dos taludes de uma seção típica, considerando a influência sobre os níveis de segurança obtidos. A utilização de outros modelos e procedimentos é sugerida com o objetivo de fornecer subsídios para futuras discussões sobre tomadas de decisão e análises de risco para os empreendimentos localizados nesta região em particular.
118

Desenvolvimento de equipamento para ensaios CRS com sucção controlada e ensaios em solos não saturados cimentados artificialmente / Development of equipment for CRS tests with controlled suction and tests with artificially cemented unsatured soils

Vieira, Gersonito da Silva 28 July 2006 (has links)
Made available in DSpace on 2015-03-26T13:27:51Z (GMT). No. of bitstreams: 1 texto completo.pdf: 5560855 bytes, checksum: 0c79ed0415d735fd465a255031f6750a (MD5) Previous issue date: 2006-07-28 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This research presents the development of equipment for CRS tests with controlled suction and tests with artificially cemented unsatured soils. It was designed and constructed four apparatus at the geotechnical laboratory of the Federal University of Viçosa. The cells have an interchangeable high air entry value ceramic disc on its base. It was also designed a software for data acquisition and an apparatus for measurement of the volume of water dislocated from the sample. It was used two residual soils from Minas Gerais. Samples prepared by compaction were used in order to assure homogeneity and to avoid deviations in test results and interpretation. The tests were carried out with different levels of applied suction. Part of the samples was prepared with the addition of different amounts of Portland cement to simulate soil matrix. After cure, these samples added with cement were saturated and subjected to CRS compression tests, using the consolidation test apparatus developed. It was noticed a structure failure at low-tension levels because of the sample elaboration method. The equipment was testified as functional. / Este trabalho apresenta o desenvolvimento de equipamentos para ensaios CRS com sucção controlada e ensaios em solos não saturados cimentados artificialmente. Foram projetadas e construídas quatro células no Laboratório de Geotecnia da Universidade Federal de Viçosa. As células têm em sua base uma pedra porosa, de alto valor de entrada de ar, intercambiável. Também foram desenvolvidos um aparato de medição de volume de água deslocado do corpo-de-prova e um programa para aquisição de dados. Utilizaram-se dois solos residuais jovens de Minas Gerais. Foram usadas amostras remoldadas por compactação com o intuito de assegurar a homogeneidade e evitar desvios nos resultados dos testes e na interpretação dos dados. Os ensaios foram conduzidos com diferentes níveis de sucção. Parte das amostras foi preparada com a adição de teores de cimento Portland pra gerar uma estruturação no solo. Após o período de cura, as amostras com adição de cimento foram saturadas e submetidas ao ensaio CRS, usando os aparatos desenvolvidos. Observou-se uma quebra da estrutura com baixos níveis de tensão devido ao método adotado na elaboração das amostras. Constatou-se um bom funcionamento dos equipamentos desenvolvidos.
119

Avaliação do método de sucção de encéfalo de morcegos (Chiroptera, Mammalia) para diagnóstico da raiva /

Gonçales, Juliano Ferreira. January 2008 (has links)
Orientador: Luzia Helena Queiroz da Silva / Banca: Wagner Andre Pedro / Banca: Elenice Maria Sequetin Cunha / Resumo: O diagnóstico laboratorial da raiva em morcegos é realizado utilizando-se, principalmente, o encéfalo do animal suspeito. O objetivo do presente trabalho foi testar a hipótese de que o método de aspiração com pipeta plástica (tipo Pasteur) é eficaz na obtenção de encéfalo de morcegos para a realização do diagnóstico comparado com o método tradicional de abertura de crânio. Para tanto, estudaram-se quatro espécies diferentes de morcegos, Molossus rufus (E. Geoffroy, 1805), Molossus molossus (Pallas, 1766), Artibeus lituratus (Olfers,1818) e Myotis nigricans (Schinz, 1821), totalizando 200 amostras. A quantidade de massa encefálica obtida pelo método tradicional foi significativamente maior, contudo, o material colhido pela aspiração foi suficiente para a execução do diagnóstico da doença. Ambos os métodos detectaram indivíduos positivos, sendo que o método de aspiração teve a vantagem de preservar o crânio possibilitando melhor identificação das espécies. / Abstract: Rabies diagnosis in bats is usually performed using the brain of suspected animals. The main hypothesis tested by this work was that aspiration method using plastic pipette (Pasteur type) was effective in the collection of bat brain sample for rabies diagnosis when compared to the opening skull method. A total of two hundred bats of four species were studied: Molossus rufus (E. Geoffroy, 1805), Molossus molossus (Pallas, 1766), Artibeus lituratus (Olfers, 1818) and Myotis nigricans (Schinz, 1821). The proportion of brain weight compared to body weight was statistically higher when using the traditional method, although the brain mass collected by aspiration method was enough for rabies diagnosis. Results demonstrate that independently of the collecting method, both gated to detect positive samples and the aspiration method has the advantage of skull preservation, permitting the identification of the species. / Mestre
120

Avaliação da coordenação sucção/deglutição/respiração através da ausculta cervical digital em recém-nascidos pré-termo e a termo

Silva, Caroline Silveira da January 2013 (has links)
Introdução: Recém- nascidos a termo nascem com a habilidade de coordenar as funções de sucção- deglutição- respiração. Recém-nascidos pré-termo não apresentam essa habilidade, consequentemente, necessitam de alimentação por sonda e podem apresentar dificuldade na transição da alimentação por sonda para via oral. O objetivo desse estudo foi comparar o padrão de coordenação sucção-deglutição-respiração de recém-nascidos a termo em aleitamento materno exclusivo e recém-nascidos pré-termo na transição da alimentação por sonda para a via oral com mamadeira. Métodos: Foram avaliados 64 recém-nascidos (32 recém-nascidos pré-termo e 32 recém-nascidos a termo) internados na UTI Neonatal e Alojamento Conjunto do Hospital Fêmina de Porto Alegre. Os recém-nascidos a termo foram avaliados durante as primeiras 48horas de vida e os recém-nascidos pré-termo foram avaliados no início da alimentação por via oral após período de alimentação por sonda orogástrica. O equipamento utilizado na ausculta cervical digital era composto por um detector acústico e por um pré-amplificador com filtro conectados a um computador Coreo 2 Duo. O microfone foi fixado com fita adesiva no pescoço do recém-nascido para captar os sinais da sucção/deglutição durante a alimentação. Três sinais de 30 segundos foram obtidos de cada RN e uma média foi obtida para os seguintes parâmetros: total de “suck-swallow signal” (SSS); duração total dos SSS; total de pausas para respirar >2,5 segundos; duração total das pausas. Os dados dos sinais dos sons da deglutição gravados foram analisados visual e auditivamente pelo Software Raven versão 1.1 Resultados: Os resultados mostraram que houve diferença estatisticamente significante para o parâmetro “duração total dos SSS”, mostrando que o tempo envolvido na sucção/deglutição é maior para os recém-nascidos pré-termo. Em relação ao parâmetro “duração total das pausas”, observou-se um tempo maior para os recém-nascidos a termo. O parâmetro “número de pausas” que indica a quantidade de momentos que o recém-nascido apresenta pausa para respirar durante a mamada no período de gravação também foi significativamente maior para os recém-nascidos a termo em comparação aos recém-nascidos pré-termo. Conclusão: Demonstramos que a ausculta cervical digital é um exame de fácil execução e minimamente invasivo na avaliação da coordenação sucção-deglutição-respiração em recém-nascidos a termo e pré-termo. Os recém-nascidos a termo com aleitamento materno durante os primeiros dias de vida apresentaram pausas para respirar mais prolongadas durante o processo de sucção-deglutiçãorespiração em comparação aos recém-nascidos pré-termo. Isso pode refletir o estágio do desenvolvimento do padrão de maturidade de processo de deglutição. / Background: Fullterm newborn are born with the ability to coordinate the functions of sucking, swallowing and breathing. Preterm infants may not have this ability, therefore, may require tube feeding and may have difficulty in the transition from tube feeding to oral feeding. The aim of this study was to compare the coordination pattern of suck, swallow and breathing in fullterm newborn exclusively breastfed and preterm newborn at the transition from tube feeding to oral bottle feeding . Methods: 64 newborn (32 preterm and 32 fullterm) admitted to the Neonatal Intensive Care Unit and Rooming-in of Femina Hospital of Porto Alegre. Fullterms were evaluated during the first 48 hours of life and preterms were assessed at the beginning of oral feeding after feeding period by orogastric tube. The equipment used in digital cervical auscultation included an acoustic detector and a preamplifier with filter connected to a computer 2 Duo Core. The microphone was fixed with tape on the neck of the newborn to capture the signals of suck / swallow during feeding. Three signals of 30 seconds were obtained from each newborn and an average was obtained for the following parameters: total number of "suck-swallow signal" (SSS); total duration of the SSS; total number of pauses> 2.5 seconds and total duration of pauses and . Signs of swallowing sounds recorded were analyzed visually and audibly by Raven Software version 1.1 Results: The results showed statistically significant differences for the parameter "total duration of the SSS," showing that the time involved in suction / swallowing is greater for preterms. As for the parameter "total duration of pauses," there was more time spent by fullterms. The parameter "number of pauses" that indicates the amount of times that newborn have respiratory pause during feeding in the recording period was also significantly higher for fullterms when compared with preterms. Conclusion: We demonstrated that digital cervical auscultation is a minimally invasive, feasible, and easy-to-perfom tool for evaluation of suck-swallowbreathing coordination in newborn. The fullterm infants with breastfeeding within the first days of life had prolonged respiratory pauses during the process of sucking, swallowing and breathing compared to preterms. This may reflect the stage of development of the natural maturity process of swallowing.

Page generated in 0.0423 seconds