• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 192
  • 107
  • 22
  • 15
  • 11
  • 7
  • 7
  • 6
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 2
  • Tagged with
  • 426
  • 426
  • 169
  • 167
  • 84
  • 75
  • 64
  • 59
  • 52
  • 48
  • 48
  • 46
  • 46
  • 38
  • 38
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
311

Propriedades mecânicas do titânio comercialmente puro e da liga Ti-6Al-4V fundidos em diferentes ambientes / Mechanical properties of commercially pure titanium and Ti-6Al-4V alloys casting in different environments

José Roberto de Oliveira Bauer 05 October 2007 (has links)
Problema: O emprego do titânio e ligas de titânio para aplicações médicas e odontológicas tem aumentado nas últimas décadas, porém, o alto custo do material desestimula o seu uso rotineiro. Objetivos: Avaliar o efeito da pureza do argônio nas propriedades mecânicas, microestrutura e modo de fratura do titânio comercialmente puro (Grau I) e da liga Ti-6Al-4V. Material e Métodos: As fundições para cada liga foram realizadas em uma máquina de indução eletromagnética com um argônio de alta pureza (99,999%) e um argônio conhecido como industrial (99,98%). Os testes de resistência à tração, limite de proporcionalidade e alongamento foram realizados em máquina de ensaio universal sob velocidade de 1 mm/min. Os espécimes fraturados foram embutidos em resina fenólica (baquelite) e polidas para a realização da microdureza Vickers (100g/15s), a a 25, 50, 100, 200 e 500?m da borda do corpo-de-prova. A microestrutura das ligas também foi analisada em alguns espécimes, com o objetivo de avaliar a superfície fraturada dos espécimes alguns foram submetidos à microscopia eletrônica de varredura. Análise estatística: Os dados provenientes de cada teste mecânico foram submetidos a uma análise de variância (tipo de titânio vs. pureza do argônio) e teste de Tukey (? = 0,05). Os dados de microdureza Vickers foram submetidos a uma análise de variância de medidas repetidas (fatores principais: liga e argônio) e medida repetida: distância e teste de Tukey para o contraste entre médias (? = 0,05). Resultados: O grau de pureza do gás não influenciou os valores do limite de proporcionalidade, da resistência à tração e alongamento, assim como a microdureza Vickers, microestrutura e padrão de fratura. A liga Ti-6Al-4V apresentou alto valores de resistência à tração, limite de proporcionalidade e microdureza Vickers, e baixo alongamento. A microdureza dos materiais foi alta nas proximidades da borda, mas a pureza do argônio não teve influência alguma. Conclusões: O argônio industrial pode ser utilizado para realizar as fundições do Ti CP e Ti-6Al-4V sem prejuízos nas suas propriedades. / Background: Although CP titanium and titanium alloys have been used for medical and dental applications, their high cost has not stimulated their current use. Objective: The purpose of this study was to evaluate the effect of argon purity on the mechanical properties, microstructure and fractography of CP Ti (Grade I) and Ti-6Al- 4V cast alloys. Material and Methods: The castings for each alloy were made in a centrifugal casting machine using either a high-purity (99.999%) and or an industrial argon gas (99.98%). The ultimate tensile strength (UTS), proportional limit (PL) and elongation (EL) were evaluated in a universal testing machine at a crosshead speed of 1 mm/min. The fractured specimens were embedded in phenolic resin and polished down for Vicker\'s microhardness (VHN) measurement (100g, 15s) from 25 ?m below the cast surface, then at 50?m, 100?m, 200?m and 500?m. The microstructures of the alloys were also revealed. Scanning electron microscopy fractography was undertaken for the fractured surfaces after tensile testing. The data from the mechanical tests and hardness were subjected to a two-way ANOVA and Tukey\'s test (? = 0.05). Results: The mean values of UTS, PL, EL and VHN were not affected by the argon gas purity. Higher UTS, PL and VHN and lower EL was observed for Ti-6Al-4V. The microhardness values of both alloys were higher at the surface layers and it was not influenced by the argon gas purity. Conclusions: It was concluded that the industrial argon gas can be safely used to cast CP Ti and Ti-6Al- 4V, since it does not alter the mechanical properties of the studied alloys.
312

"Influência de parâmetros metodológicos sobre o ensaio de microtração. Microscopia eletrônica de varredura e resistência de união" / Influence of methodological parameters on microtensile test. Scanning electron microscopy and bond strength measurements

Fernanda Tranchesi Sadek 21 October 2005 (has links)
Foi verificada a influência de 6 variáveis experimentais sobre o ensaio de microtração, a saber: sistema adesivo, formato e área de união dos corpos-de-prova (cps), velocidade e equipamento de corte e definição do grupo amostral no tratamento estatístico. Todas as variáveis foram testadas em esmalte e dentina previamente planificados. Para isolar as variáveis, o estudo foi dividido em quatro fases. 1) testou-se o tipo de adesivo: 28 molares humanos foram divididos em 4 grupos, de acordo com o substrato e com o adesivo utilizado (Excite e Clearfil SE Bond). 2) 64 dentes divididos em 16 grupos foram usados para testar: formato (ampulheta ou palito) e área de união dos cps. 3) testou-se a velocidade de corte para a obtenção dos cps, usando-se 30 molares divididos em 6 grupos. 4) 40 molares divididos em 8 grupos foram usados para analisar: equipamento de corte (disco ou fio impregnados por diamante), formato dos cps e delimitação do grupo amostral. Em todas as fases, cps foram selecionados e preparados para MEV, enquanto o restante foi submetido ao teste de microtração. Os valores de resistência de união [RU] foram coerentes com os achados em MEV, sendo os maiores valores encontrados nos grupos com melhor integridade superficial. Foi possível observar que não houve diferença estatística entre o substrato e o adesivo utilizado na fase 1. Apesar de ambos os adesivos terem conseguido íntimo contato com o substrato adjacente, muitos defeitos estruturais foram observados em MEV, principalmente em esmalte. Na fase 2, cps em dentina e em forma de palito apresentaram valores significantemente maiores de RU do que cps em esmalte e em forma de ampulheta, respectivamente. Em relação à área dos cps, quando essa aumentou de 0,25 para 4,0 mm 2 , a RU diminuiu significantemente. Foi possível verificar em cps com forma de ampulheta, através da MEV, linhas de fraturas juntamente à área de ação da.ponta diamantada, além de defeitos nos cps em forma de palito, sendo que o esmalte foi mais afetado do que a dentina. Já na fase 3, cps em dentina apresentaram maior RU do que cps em esmalte. A velocidade de corte não influenciou nos resultados dos cps em dentina, influenciando, contudo, a RU daqueles em esmalte, sendo que os cortados com velocidade alta (400 RPM) mostraram defeitos mais pronunciados em MEV e menores RU do que os cortados com velocidades menores (100 e 200 RPM). Na fase 4, cps em esmalte cortados com o fio impregnado por diamante foram estatisticamente mais resistentes do que aqueles cortados com disco, sendo que este grupo apresentou maior quantidade de defeitos em MEV, o mesmo não acontecendo em dentina. Cps em forma de palito foram mais resistentes do que aqueles em forma de ampulheta. A inclusão/exclusão das fraturas prematuras foi estatisticamente significante para ambos os substratos. Concluímos que cps em forma de ampulheta devem ser evitados, principalmente em esmalte, recomendando, assim, o uso de cps em forma de palito, com áreas próximas a 1 mm 2 . O seccionamento para obtenção dos cps em esmalte deve ser feito preferencialmente com fio. Quando a utilização do disco for inevitável, velocidades baixas são aconselháveis. A inclusão das fraturas prematuras, como valor de resistência de união igual a zero, proporciona resultados mais representativos sobre o complexo processo que envolve o teste de microtração. / The influence of 6 methodological parameters in the results of the microtensile test was evaluated, as described: adhesive system, shape and area of the specimens, cutting speed and equipment, experimental groups’ definition for the statistical analyses. All variables were tested in flattened dentin and enamel. 1) The type of adhesive system was evaluated: 28 human molars were divided into 4 groups according to the substrate and the adhesive used (Excite or Clearfil SE Bond). 2) 64 teeth divided into 16 groups were used to test: shape (hourglass and stick) and area of the specimens. 3) Cutting speed used to obtain specimens was tested, using 30 molars divided into 6 groups. 4) 40 molars were divided into 8 groups and used to analyze: cutting equipment (blade or wire impregnated by diamond), shape of the specimens and experimental groups’ delimitation. In all the above trials, some specimens were randomly selected and prepared for SEM, while the remaining were submitted to microtensile test. Microtensile bond strength data collected was coherent to the SEM images observed; higher values were found for the groups wherein better integrity was observed. It was possible to verify that there were no statistically differences between substrates and adhesives used in the first trial. Even tough both systems showed intimate contact with the adjacent tissue, many structural defects were observed in SEM, mainly in enamel. In the test 2, dentin and stick-shaped specimens gave significantly higher values of bond strength than enamel and hourglass-shaped specimens, respectively. As for specimens’ thickness, when it increases from 0.25 to 4.0 mm 2 , the recorded microtensile bond strength decreases. It was possible to verify, through SEM, line of fracture in the area of action of the bur in the hourglass-shaped specimens and structural defects in the stick-shaped specimens, being enamel more affected than dentin. In the third trial, specimens in dentin showed significantly higher values of bond strength than specimens in enamel..Cutting speed did not influence the results of the dentin’s specimens; however, it influenced those in enamel, where the ones cut with higher cutting speed (400 RPM) had more pronounced defects in SEM and lower bond strength values when compared to those cut with lower cutting speeds (100 and 200 RPM). In the experiment 4, enamel’s specimens sectioned with the diamond wire showed statistically higher bond strengths than those cut with blade, being this last group the one that showed more structural defects during SEM analyzes, which did not happen in dentin. Stick-shaped specimens were more resistant than hourglass-shaped specimens. The inclusion/exclusion of premature failures was statistically significant for both substrates. We conclude that hourglass-shaped specimens should be avoided, especially on enamel, where the use of stick specimens is highly recommended, with cross-sectional area of 1 mm 2 . The sectioning action to obtain enamel specimens should be done with wire equipments. However, when the use of diamond blade is unavoidable, low cutting speeds are advisable. Premature failures should be included as null bond strength values to represent fully all factors involved in the microtensile process.
313

Efeito da irradiação com laser de diodo sobre adesivos dentinários / Effect of diode laser irradiation on dentin-bonding agents

Rafael Massunari Maenosono 10 May 2017 (has links)
A irradiação de sistemas adesivos com laser tem obtido resultados promissores, no entanto, seu mecanismo de ação, bem como a longevidade da camada híbrida obtida após a irradiação com laser ainda não estão bem estabelecidos na literatura. A presente tese teve como objetivo: avaliar a absorvância do laser de Diodo por diferentes sistemas adesivos por meio de espectroscopia no infravermelho próximo; avaliar a evaporação de água e solventes proporcionada pelo laser por meio da variação da massa analisada em balança de precisão; avaliar a resistência de união por meio de teste de microtração após envelhecimento de 12 meses. Os dados obtidos foram analisados por modelos de ANOVA, seguidos de teste Tukey (p<0,05) e os resultados demonstraram que: a irradiação no infravermelho próximo, área do espectro eletromagnético que compreende o laser de Diodo, não apresenta interação com os sistemas adesivos testados; o laser de Diodo é capaz de proporcionar maior alteração de massa, mesmo após contínua evaporação dos solventes com jatos de ar por 60s; sistemas adesivos simplificados apresentaram valores de resistência de união imediato semelhantes aos valores obtidos após 12 meses de envelhecimento. Os dados obtidos neste estudo sugerem que a irradiação com laser de Diodo pode contribuir favoravelmente para a adesão em dentina com sistemas adesivos simplificados após 1 ano. / The laser irradiation of adhesive systems has obtained promising results, however, its mechanism of action, as well as the longevity of the hybrid layer obtained after laser irradiation are still not yet well established in the literature. This thesis aimed to: assess the diode laser interaction with different adhesive systems by means of near infrared spectroscopy; evaluate the evaporation of solvents and water provided by the laser through the mass variation analyzed at a precision balance; evaluate the bond strength through microtensile bond strength test after 12 months of aging. The data was analyzed through ANOVA models, followed by Tukey test (p<0.05), and the results demonstrated that: in the near-infrared irradiation area, the electromagnetic spectrum comprising the diode laser, shows no interaction with the adhesive systems tested; the diode laser was able to provide greater mass variation, even after continual evaporation of solvents with air jets for 60s; simplified adhesive systems presented immediate bond strength values similar to the ones verified after 12 months of aging. The data obtained in this study suggest that the Diode laser irradiation can contribute favorably for the adhesion between dentin and simplified adhesive systems after 1 year.
314

Método de determinação de resistência à  tração e módulo de elasticidade de partí­culas de agregados graúdos naturais. / Mechanical properties of natural aggregate paricles and their influence on the mechanical behavior of concrete.

Natalia Vieira da Silva 22 February 2018 (has links)
Esse trabalho tem como objetivo estabelecer um método simples de ensaio que permita determinar a resistência à tração e módulo elástico de partículas individuais de agregados graúdos naturais submetidas à carga de compressão. O método de ensaio foi desenvolvido baseado no ensaio de carga pontual (Point Load Test) que permite obter a resistência à tração de partículas. Para a determinação do módulo de elasticidade foi acoplado ao método um LVDT e foi satisfeita a condição para aplicação da teoria de contato de Hertz (contato curvo-plano entre as partículas e as fixações de aplicação da carga). Inicialmente a metodologia foi avaliada utilizando como material de referência partículas de vidro (com geometrias similares aos agregados). Após a validação no vidro, o método de ensaio foi aplicado em agregados graúdos de granito. Propôs-se um método de seleção de partículas com base na sua distribuição de frequência de absorção, com o intuito de reduzir a quantidade de partículas testadas mecanicamente necessárias para obter a distribuição de Weibull da resistência à tração (e módulo de elasticidade). Para tanto, foi feita a determinação da absorção de água individual de centenas de partículas selecionadas por amostragem a esmo da população de agregados. Com base nos resultados, foi possível determinar a distribuição de Weibull da resistência à tração e módulo de elasticidade das partículas. Observou-se que as resistências à tração variaram de 3 a 15 MPa. Os agregados possuíam aproximadamente 10% da população de partículas com resistência à tração inferior a 5 MPa, o que pode influenciar as classes de resistência à compressão de concretos >50MPa. Os módulos elásticos dos agregados também foram variáveis (18-67 GPa) e aproximadamente 10% da população de partículas com módulo elástico <30 GPa. Isso pode limitar o módulo de elasticidade do concreto (que geralmente é em torno de 27 GPa), dependendo do processo de escolha dos agregados. As funções exponenciais inversas fundamentais entre essas propriedades mecânicas e a porosidade foram confirmadas (para valores médios). / The aim of this work is to establish a simple test method to determine the tensile strength and elastic modulus of individual natural aggregate particles subjected to a compression load. The test method was developed based on the Point Load Test, that allows to obtain the tensile strength of particles. For the determination of the elastic modulus, an LVDT was coupled to the method and the condition for application of Hertz contact theory (curved-plane contact between the particles and the load application fixations) was satisfied. Initially, the method was evaluated using glass particles as reference (with geometries similar to aggregates). After validation on the glass, the test method was applied to coarse granite aggregates. A method of particle selection was proposed based on its absorption frequency distribution, in order to reduce the amount of mechanically tested particles required to obtain the Weibull distribution of tensile strength (and elastic modulus). For this purpose, the determination of the individual water absorption of hundreds of particles selected by random sampling of the population of aggregates was made. Based on the results, it was possible to determine the Weibull distribution of the tensile strength and elastic modulus of the particles. The tensile strengths ranged from 3 to 15 MPa. The aggregates had approximately 10% of the particles population with tensile strength less than 5 MPa, which may influence the classes of concrete with compressive strength > 50MPa. The elastic modulus of the aggregates was also variable (18-67 GPa), with approximately 10% of the particle population with elastic modulus <30 GPa. This may limit the elastic modulus of the concrete (usually around 27 GPa) depending on how the aggregates are selected. The fundamental inverse exponential functions between these mechanical properties and the porosity were confirmed (for mean values).
315

Influência da dentina sadia e afetada por cárie na resistência de união de sistemas adesivos e cimentos de ionômero de vidro em dentes decíduos - estudo in vitro / Influence of sound or caries-affected dentin on the bond strength of adhesive systems and glass ionomer cements in primary teeth an in vitro study

Fabiana Bucholdz Teixeira Alves 08 December 2010 (has links)
O objetivo deste estudo foi avaliar a influência do substrato dentinário sadio e afetado em dentes decíduos, após restaurações realizadas com diferentes materiais, na resistência de união e nanoinfiltração. Setenta e dois segundos molares receberam preparos padronizados na superfície oclusal e foram divididos aleatoriamente em dois grupos. Um grupo foi denominado dentina sadia [DS] (n=36), e o outro foi submetido ao desafio cariogênico artificial (ciclagem de pH) denominado dentina afetada [DA] (n=36). Posteriormente, os dentes foram restaurados (n=6) com os seguintes materiais: cimento de ionômero de vidro modificado por resina (CIVMR) com nanopartículas - KetacTM N100 [KN100], CIVMR - Vitremer [VI], cimento de ionômero de vidro de alta viscosidade (CIVAV) - KetacTM Molar Easy Mix [KME], Sistema Adesivo autocondicionante de passo único AdperTM Easy One Self-Etch Adhesive [EASY], sistema adesivo autocondicionante de dois passos - AdperTM SE Plus [SE], sistema adesivo com condicionamento ácido total - AdperTM Single Bond 2 [SB]. Os grupos dos sistemas adesivos receberam restauração com resina composta (Filtek Z250). Após 24 horas de armazenagem em água destilada (37ºC), os dentes foram seccionados no sentido vestíbulo-lingual e novos cortes no sentido mésiodistal de forma a obter palitos com secção transversal de 1 mm2 de área. Os espécimes foram submetidos ao teste de microtração (1,0 mm/min) e o modo de falha foi determinado utilizando um microscópio óptico (400x). Um espécime de cada dente foi imerso 24 h em uma solução de nitrato de prata 50% por peso e posteriormente imersos em solução reveladora sob luz fluorescente, por 8 horas. A quantidade de penetração foi avaliada por único examinador, cego em relação aos grupos, por meio de imagens em microscópio eletrônico de varredura em modo de elétrons retroespalhados, sendo adotado escore de 0 a 3. A concordância intraexaminador foi de 0,87. A média dos valores de resistência de união de cada material foi submetida à análise de variância de dois fatores e complementado pelo teste de Tukey. Para os dados da nanoinfiltração foram utilizados o teste de Kruskal Wallis e Mann-Whitney. O nível de significância adotado foi de 5%. A média (±desvio padrão) de cada material, em dentina sadia foi: KN100: 35,2 (±9,4); VI: 29,2 (±7,8); KME: 18,8 (±2,7); EASY: 27,12 (±2,42); SE: 18,77 (±7,23); SB: 37,32 (±3,95). Para dentina afetada: KN100: 35,8 (±6,7); VI: 24,9 (±5,7); KME: 14,5 (±0,7); EASY: 14,32 (±5,79); SE: 13,29 (±3,43); SB: 19,36 (±4,06). O tipo de falha mais freqüente independente do tipo de substrato foi coesiva para o CIVAV e adesiva para os sistemas adesivos e CIVMR. O fator substrato dentinário não influenciou significativamente a infiltração de prata na interface. Pode-se concluir que os CIVs não sofrem influência na resistência adesiva em relação ao substrato. Entretanto, os sistemas adesivos autocondicionante de passo único e condicionamento prévio são influenciados pelo substrato afetado por lesão de cárie. / The aim of this study was to evaluate the influence of sound and caries-affected dentin of primary teeth restored with different materials, regarding bond strength and nanoleakage. Seventy two primary second molars received standardized occlusal preparations were randomly assigned in two groups. One group was nominated as sound dentin [SD] (n=36), and the other was submitted to artificial caries challenge (pH cycling), called caries affected dentin [CAD] (n=36). Six teeth in each group were restored according to dental material: resin modified GIC with nanoparticles Ketac TM Nano [KN100], a resin modified GIC - Vitremer [VI], high viscosity glass ionomer cement KetacTM Molar Easy Mix [KME], one-step self-etch adhesive system AdperTM Easy One Self-Etch Adhesive [EASY], two-step self-etch adhesive system - AdperTM SE Plus [SE], total-etching adhesive system - AdperTM Single Bond 2 [SB]. The adhesive systems groups were restored with composite resin (Filtek Z250). After storage in distilled water (37ºC) for 24 hours, the teeth were sectioned in buccallingual direction and then in the mesial-distal to obtain bonded sticks (1 mm2). The specimens were subjected to microtensile test (1.0 mm/min) and the failure mode was determined using an optical microscope (400x). One dentin-material stick from each tooth was immersed in silver nitrate solution 50% weight per volume (24 h) and immersed in revealing solution under fluorescent light, for 8 hours. One examiner, blinded regarding groups, evaluated the images using scanning electron microscope adopting scores ranging from 0 to 3. The intra-examiner agreement was 0.87. The values of bond strength from each material were analyzed by two-way ANOVA and Tukey post hoc test. For the nanoleakage data, Kruskal-Wallis and Mann-Whitney tests were used, with level of significance set on 5%. The mean (and standard deviations) for each material, in sound dentin were: KN100: 35.2 (±9.4); VI: 29.2 (±7.8); KME: 18.8 (±2.7); EASY: 27.12 (±2.42); SE: 18.77 (±7.23); SB: 37.32 (±3.95). For caries-affected dentin: KN100: 35.8 (±6.7); VI: 24.9 (±5.7); KME: 14.5 (±0.7); EASY: 14.32 (±5.79); SE: 13.29 (±3.43); SB: 19.36 (±4.06). The most frequent type of failure regardless of substrate was cohesive, for KME, and adhesive, for the adhesive systems and RMGICs. Sound or caries-affected dentin did not significantly affect the infiltration of silver nitrate into the interface. It can be concluded that the bond strength of GICs are not influenced by the substrate, however, the one-step self-etch adhesive system and total-etching are influenced by caries-affected dentin.
316

A influência da água na composição de primers autocondicionantes experimentais / Influence of the water concentration in an experimental self-etching primer on the bond strength to dentin

Lima, Giana da Silveira 21 December 2007 (has links)
Made available in DSpace on 2014-08-20T14:30:07Z (GMT). No. of bitstreams: 1 Dissertacao_giana_da_silveira_lima.pdf: 1493174 bytes, checksum: 68e4c67538ad95eba022c0a0e790d4b8 (MD5) Previous issue date: 2007-12-21 / To investigate the influence of different water concentrations in self-etching primers solvents on microtensile bond strength (μTBS) of an experimental adhesive system. Five experimental self-etching primers with 0, 5, 10, 20 and 40 water concentration (wt %) in solvent, were synthesized. Clearfil SE Bond (CSEB) was used as commercial adhesive. Sixty bovine incisive were randomize separated in six groups (n=20). Vestibular enamel was removed to expose the superficial coronal dentin, this surface was polished wet to create a standardized smear layer. After rinsing, water was removed, leaving the surface visibly dried. The dentin surfaces were etched with primer and air-dried, after coating adhesive resin was applied and photo-activated, following the composite resin restoration was accomplished. After storage for 24 hours, the specimens were sectioned with a refrigerated diamond saw at low-speed. Microtensile bond strength were measured and data were analyzed by one-way ANOVA/Tukey s test (α=0.05). Analysis of variance showed that primer composition was a significant factor for bond strength. There was not difference on bond strength of the primers with water concentration: 40% (53.9 ± 12.7 MPa), 20% (51.1 ± 11.5 MPa) and 10% (47.5 ± 11.4 MPa) and CSEB (52.44 ± 13.27 MPa). The group with 5% (38.6 ± 12.9 MPa) and 0% (31.5 ± 7.5 MPa), present similar bond strength amongst themselves but statistically smaller that the other groups. The water concentration, present in the primer solvent, exercise significant influence on the bond strength of this experimental self-etching adhesive system / Este estudo avaliou a influência de diferentes concentrações de água no solvente de um primer autocondicionante de um sistema adesivo dentinário experimental. Foram formulados cinco primers experimentais com diferentes concentrações, 0; 5; 10; 20; 40%, de água em massa e Clearfil SE Bond (CSEB) foi utilizado como referência comercial. Foram utilizados 60 incisivos bovinos, distribuídos aleatoriamente entre 6 grupos (n= 20). Na face vestibular dos dentes foi realizado desgaste com lixas até a exposição de dentina com lixa d água 600. O primer foi aplicado sobre a dentina previamente seca com papel absorvente, sendo aplicado jato de ar e em seguida o adesivo foi aplicado e foto-ativado com aparelho fotopolimerizador LED SDI Radii®. A restauração foi confeccionada utilizando 2 incrementos, fotoativados de acordo com as recomendações do fabricante. Após armazenagem por 24 horas em água destilada à 37°C, os dentes foram seccionados em cortadeira de precisão e a resistência de união mensurada, através de ensaio de microtração em uma máquina de ensaios mecânicos. Análise de Variância segundo um critério e teste complementar de Tukey foram utilizados na análise estatística (α=5%). Não houve diferença na resistência de união de P40 (53,9 ±12,7 MPa) P20 (51,1 ±11,5 MPa) e P10 (47,5 ±11,4 MPa) e CB (52,44 ±13,27 MPa). Os grupos P5 (38,6 ±12,9 MPa) e P0 (31.5 ±7.5 MPa) não apresentaram diferença estatística entre si, mas seus valores de adesão dentinária foram menores que os demais grupos (p<0,05). A resistência de união dentinária do sistema adesivo experimental testado sofre influência da concentração de água presente no solvente do primer autocondicionante
317

Desenvolvimento de compósito fotoativado para aplicação em coberturas periodontais temporárias / Development of photoactivated composite for application in periodontal temporary roofing

Conceição, Luciana Domingues 20 December 2012 (has links)
Made available in DSpace on 2014-08-20T14:30:10Z (GMT). No. of bitstreams: 1 Dissertacao_Luciana_Conceicao.pdf: 1166387 bytes, checksum: 74e97c6a817eb6fb90d26b94051d237d (MD5) Previous issue date: 2012-12-20 / The application of a material after periodontal surgery is recommended to reduce postoperative bleeding, to protect the wound area and to avoid the formation of excessive granulation tissue. The current trend is the development of new biomaterials eugenol-free for surgical application. The aim of this study was to develop and characterize a periodontal dressing based on photopolymerizable methacrylate monomers. For this purpose, a screening was made to determine the best formulation based on the ease of handling and the use of Exothane 8 , camphorquinone, silica and quartz particles. Three groups were tested: Gperio (Group of periodontal dressing Periobond®, Dentsply); Gbar (Group of periodontal dressing Barricaid®, Caulk), which served as the reference group and Gexp (Group of experimental material). The physical-mechanical performance of the experimental composite and the commercial references Periobond® and Barricaid® (control group) were tested using in vitro tests of tensile strength (n = 15) and sorption and solubility (n = 10). Cytotoxicity (MTT colorimetric assay) and genotoxicity by micronuclei (MN) tests were performed in a cell lineage of mouse fibroblasts 3T3/NIH, in triplicate, in order to characterize the biological response of these materials. Microbiological test assess the amount of viable bacteria of Enterococcus faecalis anaerobic and aerobic and total microorganisms. Data were subjected to statistical analysis based on the model of normal distribution and equal variance One-Way ANOVA, considering the value of P<0.05 as statistically significant. There were no statistically significant differences between the median values of Gexp and Gbar, for ultimate tensile strength. Regarding the sorption there was statistical difference between Gperio and Gexp and between Gperio and Gbar (P=<0.001). There was no difference when comparing Gbar and Gexp. The solubility showed no statistical difference between groups. In general, the cytotoxic effects of the materials were time dependent according to eluate extraction periods (24h, 48h and 7 days). No statistical difference at 24h between Gexp and Gperio. At 72h, differences were observed between Gexp and Gperio (P<0.001) with Gexp showing the best results. Similar results were seen between Gbar and Gperio (P<0.001). At 7 days, statistical difference was observed between Gbar and Gperio (P<0.05). In genotoxicity test no difference was found among the groups. In microbiological assay no statistical difference was found for E. faecalis anaerobic, E. faecalis aerobic and for total microorganisms. We conclude that Gexp experienced similar behavior to the commercial samples and can be possibly used as a periodontal dressing; however, more studies are needed at pre-clinical and clinical levels / A aplicação de um material após a cirurgia periodontal é recomendada para reduzir o sangramento pós-operatório, proteger a área da ferida e evitar a formação excessiva de tecido de granulação. A tendência atual é o desenvolvimento de novos biomateriais para aplicação cirúrgica livres de eugenol. O objetivo do presente estudo foi desenvolver e caracterizar um material cirúrgico periodontal baseado em monômeros metacrilatos fotopolimerizável com formação de polímero de alta flexibilidade. Para isso, foi realizado um screening para se determinar a melhor fórmula baseada na facilidade de manuseio do material e considerando a utilização de Exothane 8 , canforoquinona, e partículas de sílica e quartzo. Três grupos foram testados; Gperio (Grupo cimento periodontal Periobond®, Dentsply); Gbar (Grupo cimento periodontal Barricaid®, Caulk, que serviu como grupo de referência comercial) e Gexp (Grupo do material experimental). Foi avaliado o desempenho físico-mecânico do compósito experimental e das referências comerciais: Periobond® e Barricaid® (grupos controle), através dos ensaios in vitro de resistência à tração (n=15) e sorção e solubilidade (n=10). Testes de citotoxidade (ensaio colorimétrico com MTT) e de genotoxicidade através do ensaio de micronúcleos (MN) em linhagem celular de fibroblastos de camundongo 3T3/NIH, foram realizados em triplicata, com o intuito de caracterizar a resposta biológica desses materiais. Teste microbiológico para avaliar a quantidade de bactérias viáveis de Enterococcus faecalis anaeróbicos, aeróbicos e micro-organismos totais. Os dados obtidos foram submetidos ao método estatístico baseado no modelo de distribuição normal e igualdade de variância (ANOVA 1 via), considerando-se o valor de P<0,05 como estatisticamente significante. Não foram encontradas diferenças estatisticamente significantes entre os valores medianos do Gexp e Gbar, em relação à resistência máxima a tração. Em relação à sorção houve diferença estatística entre Gperio e Gexp e entre Gperio e Gbar (P<0,001). Não houve diferença estatisticamente significante quando comparamos Gbar e Gexp. Em relação à solubilidade não houve diferença estatística entre os grupos. Em geral, os efeitos citotóxicos dos materiais foram dependentes do tempo de extração do eludato (24h, 48h e 7 dias). Foi encontrada diferença estatística no tempo de 24h entre Gexp e Gperio. No tempo de 72h houve diferença entre Gexp e Gperio (P<0,001), tendo o primeiro melhor comportamento, da mesma forma entre Gbar e Gperio (P<0,001). Em 7 dias, houve diferença estatística entre Gbar e Gperio, tendo resultado de P<0,05. No teste de genotoxicidade não foi encontrada diferença estatística entre os grupos. No ensaio microbiológico não foi encontrada diferença estatística para E. faecalis anaeróbicos, E. faecalis aeróbicos ou micro-organismos totais. Concluímos que Gexp teve comportamento semelhante aos controles podendo ser utilizado como material para recobrimento de feridas cirúrgicas periodontais, sendo necessários mais estudos de fase pré-clínica e clínica.
318

Influência da composição do primer sobre a resistência de união à microtração em sistema adesivo autocondicionante experimental / Influence of experimental self-etching primers composition on microtensile bond strength

Madruga, Francine Cardozo 21 December 2006 (has links)
Made available in DSpace on 2014-08-20T14:30:10Z (GMT). No. of bitstreams: 1 Dissertacao_Francine_Cardozo_Madruga.pdf: 401845 bytes, checksum: 455f72341e671454f219f56884bf2224 (MD5) Previous issue date: 2006-12-21 / The aim of this study was to investigate the influence of different functional monomer concentrations/HEMA in self-etching primers solvents on microtensile bond strength (μTBS) of an experimental adhesive system. Seventy bonive incisors were allocated in seven groups (n=20). Six experimental self-etching primers were synthesized with different concentratios of acidic monomer (MPF); 0, 15, 30, 50, 70 and 100 (wt %)(Groups EMa0, EMa15, EMa30, EMa50, EMa70, EMa100 respectively). Adhesive system Clearfil SE Bond (CSEB, Kuraray) was used as control. Coating adhesive resin AP-50 was prepared Seventy bovine incisors were randomized and allocate in seven groups. Vestibular enamel was grounded to expose the superficial coronal dentin, witch that was polished wet to create a standardized smear layer with 600 grit silicon paper. After rinsing, water was removed with a piece of absorbent paper, leaving the surface visibly dried. The prepared dentin surfaces were etched with primer and air-dried, after coating adhesive resin was applied and light activated with LED SDI Radii® (1400mW/cm2). The composite resin was inserted in two increments and were ligth activated for 20 s each. After storage for 24 hours, the specimens were sectioned with a refrigerated diamond saw at low-speed. To investigate immediate microtensile bond strength (μTBS) statistical analysis were performed (one-way ANOVA plus Tukey s post-hoc test, α=0.05). Fractographic analysis were performed using optical microscopy to describe failure patterns. The group EMa50 showed statistically higher (p<0.05) microtensile bond strength (55.1MPa) than others experimental groups but was similar with control (50.7MPa). Due total premature failure groups EMa0 and EMa100 were exclude form statistics. Groups EMa15, EMa30 and EMa70 were similar but different that control. Was possible conclude that concentration of acidic monomer/HEMA affects microtensile bond strength of self-etching adhesive systems. Primer composition of 50%MPF-20%HEMA- 30% water showed satisfactory microtensile bond strength as a self-etching adhesive system. / O objetivo deste estudo foi avaliar a influência de diferentes composições variando as concentrações de monômero ácido/HEMA em primer autocondicionante de sistema adesivo dentinário experimental. Foram utilizados 70 incisivos bovinos, distribuídos aleatoriamente entre 7 grupos (n=20). Foram formulados seis primers experimentais com concentrações de 0; 15; 30; 50; 70%; e 100% de monômero ácido (MPF) em massa (Grupos EMa0, EMa15, EMa30, EMa50, EMa70, EMa100 respectivamente). O sistema adesivo Clearfil SE Bond (CSEB, Kuraray) foi utilizado como controle. Na face vestibular dos dentes foi realizado desgaste até a exposição de dentina com lixa d água granulação até 600. O primer foi aplicado vigorosamente sobre a dentina previamente seca com papel absorvente, sendo aplicado jato de ar e em seguida o adesivo foi aplicado e foto-ativado com aparelho fotopolimerizador LED SDI Radii® (1400mW/cm2). A restauração foi confeccionada utilizando 2 incrementos de 2 mm de compósito,fotoativados de acordo com as recomendações do fabricante. Após armazenagem por 24 horas em água destilada a 37°C, os dentes foram seccionados em cortadeira de precisão e a resistência de união (MPa) mensurada através do ensaio de microtração em uma máquina de ensaios mecânicos. As amostras fraturadas do ensaio de microtração foram avaliadas por microscopia óptica e classificadas quanto ao modo de fratura. Análise de Variância segundo um critério e teste complementar de Tukey foram utilizados para detectar diferenças entre médias (α=5%). O grupo EMa50 apresentou o maior valor (p<0,05) de resistência de união à microtração em dentina (55,1MPa) entre os primers experimentais, sendo esse valor semelhante ao encontrado no controle comercial (50,7MPa). Os grupos EMa0 e EMa100 demostraram-se inviáveis por apresentarem totalidade de falhas prematuras e foram excluídos da estatística, os grupos EMa15, EMa30e EMa70 foram semelhantes e estatisticamente inferiores ao controle. Baseado na metodologia do presente estudo foi possível concluir que variações de concentração de monômero ácido/HEMA na composição de sistemas adesivos autocondicionantes afetam os valores de resistência de união à dentina sendo que a composição 50%MPF-20%HEMA-30%Água demonstrou valores iniciais satisfatórios de resistência de união para o desenvolvimento de um sistema adesivo experimental autocondicionante.
319

Influence des sables fillérisés calcaires sur les propriétés des bétons courants et superplastifiés. Un exemple tunisien / Influence of limestones sands rich of fillers on the properties of the concretes with and without superplasticizer. A Tunisian example

Joudi-Bahri, Imène 10 November 2012 (has links)
L'objectif de la thèse est d'étudier l'effet de la quantité de fillers vis-à-vis des propriétés rhéologiques, mécaniques et dimensionnelles de bétons tout calcaire. Ces bétons ont été confectionnés avec les mêmes gravillons et le même sable provenant de la même production, afin d'éviter tout artéfact. Le sable a servi à fabriquer cinq sables représentatifs des catégories définies dans la norme EN 12260 des granulats à bétons, par mélange avec sa fraction fine ou sa fraction grenue extraites préalablement par lavage. Les sables fabriqués contiennent environ 0, 6, 12, 18 et 24% de fillers. Les bétons ont été formulés avec le logiciel BetonlabPro2, dont les algorithmes prennent en compte la présence des fillers calcaires. Les bétons ont été réalisés tout d'abord sans superplastifiant, puis en présence d'un superplastifiant dosé à 2/3 de la saturation. Les résultats obtenus ont montré qu'une quantité de fillers de 100 à 130 kg/m3 pour les bétons courants et de 60 à 80 kg/m3 pour les bétons superplastifiés, permet d'obtenir des propriétés optimales, à consistance égale. Mais des quantités supérieures de fillers n'altèrent pas significativement les propriétés des bétons, même si leur compacité diminue. On explique ce comportement non seulement par l'effet liant attribué aux fillers calcaires, mais aussi par une amélioration de la liaison pâte granulats. Les mélanges contenant les plus forts taux de fillers ont encore été étudiés pour formuler des bétons autoplaçants BAP, qui nécessitent une grande quantité de fillers. Les sables de concassage apportent alors la majeure partie de ce constituant, ce qui leur ouvre une voie nouvelle d'utilisation / The objective of this work is to study the effect of the quantity of fillers on the rheological, mechanical and dimensional properties of calcareous concretes. These concretes were made with the same coarse aggregates and same sand coming from the same production, in order to avoid any artifact. Sand was used to manufacture five sands representative of the categories defined in the EN 12260 norm for aggregates for concretes, by mixture with its fine fraction or its grained fraction extracted beforehand by washing. The employed sands contain approximately 0, 6, 12, 18 and 24 % of fillers. The concretes were formulated with the BetonlabPro2 software, whose algorithms take into account the presence of the fillers limestones. Concretes were realized at first without superplastifiant, then in the presence of a superplastifiant measured in 2/3 of saturation. The obtained results showed that a quantity of fillers limestones from 100 to 130 kg/m3 for the concretes and from 60 to 80 kg / m3 for superplasticizred concretes allows obtaining optimal properties, in equal consistency. But, higher quantities of fillers do not deteriorate significantly the properties of the concretes, even if their packing density decreases. One explains this behavior not only by the binding effect allotted to the fillers limestones, but also by an improvement of the paste-aggregates bond. Mixtures containing the strongest rates of fillers were again studied to formulate self compacting concretes SCC, which require a big quantity of fillers. Crushed sands bring then the major part of this constituent, what opens to them a new way of use
320

Influence of the Melt Flow Rate on the Mechanical Properties of Polyoxymethylene (POM) / Einfluss des Schmelzfließindex auf die mechanischen Eigenschaften von Polyoxymethylen (POM)

Faust, Karsten, Bergmann, André, Sumpf, Jens 19 December 2017 (has links) (PDF)
In this article the correlation between the average molar mass and the melt flow rate (MFR) is achieved. Based on the example of Polyoxymethylene (POM) it is shown that a high average molar mass is associated with a low MFR (high viscosity). On the basis of this dependency, the mechanical properties of static and dynamic tensile strength, elastic modulus, hardness and notched impact strength are investigated. It was found that the characteristic values of static tensile strength, elastic modulus and hard-ness increase with increasing MFR (decreasing viscosity). On the other hand the dynamic long-term properties and notched impact strengths decrease with increasing MFR. / Im Beitrag wird der Zusammenhang zwischen der mittleren molaren Masse und des Schmelzfließindex (MFR) hergestellt. Dabei wird am Beispiel von Polyoxymethylen (POM) ersichtlich, dass eine hohe mittlere molare Masse mit einem geringen MFR (hochviskos) einhergeht. Basierend auf dieser Abhängigkeit werden die mechanischen Eigenschaften statische und dynamische Zugfestigkeit, E-Modul, Härte sowie Kerbschlagzähigkeit untersucht. Dabei konnte festgestellt werden, dass die Kenngrößen statische Zugfestigkeit, E-Modul und Härte mit steigendem MFR (abnehmende Viskosität) zunehmen. Die dynamischen Langzeiteigenschaften und Kerbschlagzähigkeiten sinken hingegen mit zunehmendem MFR.

Page generated in 0.1389 seconds