• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 12
  • Tagged with
  • 12
  • 12
  • 12
  • 11
  • 5
  • 4
  • 4
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Análise do processo de atendimento a itens não conformes no campo / not available

Salvador, Carlos Cesar 20 December 2004 (has links)
A confiabilidade do produto é um dos principais atributos da sua qualidade, porém a melhoria contínua desta confiabilidade é um objetivo inalcançável para as empresas, principalmente após o processo de globalização, no qual as empresas locais não têm como competidores apenas as empresas regionais ou nacionais, mas também as outras empresas mundiais. Outro fator importante, para o estabelecimento da confiabilidade, é o cliente que têm aumentado as suas exigências num processo contínuo, em que os aspectos de conformidade às especificações do projeto estão se tornando critério de compra. Este trabalho, através de um estudo de caso, apresenta a análise de um processo de atendimento a itens não conformes e propõe melhorias neste processo, visando agilizar a solução de problemas de campo. Para isso será avaliada a confiabilidade da empresa, desde a comunicação do cliente, passando pelo revendedor e da própria empresa, até a metodologia utilizada para a análise das falhas de campo dos produtos existentes. Os registros e informações da área de suporte e serviços, serão fundamentais para a introdução de melhorias para o procedimento atualmente em uso pela empresa. / The reliability of a product is one of the main attributes of its quality, however continuous improvement of its reliability is a never-ending journey for companies, especially those with global processes, as they must complete with other regional, national and global companies. Another important factor in determining the reliability of a product is the understanding of the critical customer requirements. Due to market globalization, consumers now have access to a greater variety of products and are better able to make comparisons between similar items. This ability drives consumers to constantly change or refine their critical requirements that ultimately influence their purchasing decisions. This case study presents an analysis of a process for monitoring product non-conformances and proposes process improvements aimed at speeding up the solution to field problems. To do this, company reliability will be analyzed in terms of the path of communication of product problems from the customer to the dealer, the dealer to the factory and from the factory to the methodology used to analyze field failures. Information from the product support and services area will be fundamental to the introduction of improvements to the current field failure processes.
2

Análise do processo de atendimento a itens não conformes no campo / not available

Carlos Cesar Salvador 20 December 2004 (has links)
A confiabilidade do produto é um dos principais atributos da sua qualidade, porém a melhoria contínua desta confiabilidade é um objetivo inalcançável para as empresas, principalmente após o processo de globalização, no qual as empresas locais não têm como competidores apenas as empresas regionais ou nacionais, mas também as outras empresas mundiais. Outro fator importante, para o estabelecimento da confiabilidade, é o cliente que têm aumentado as suas exigências num processo contínuo, em que os aspectos de conformidade às especificações do projeto estão se tornando critério de compra. Este trabalho, através de um estudo de caso, apresenta a análise de um processo de atendimento a itens não conformes e propõe melhorias neste processo, visando agilizar a solução de problemas de campo. Para isso será avaliada a confiabilidade da empresa, desde a comunicação do cliente, passando pelo revendedor e da própria empresa, até a metodologia utilizada para a análise das falhas de campo dos produtos existentes. Os registros e informações da área de suporte e serviços, serão fundamentais para a introdução de melhorias para o procedimento atualmente em uso pela empresa. / The reliability of a product is one of the main attributes of its quality, however continuous improvement of its reliability is a never-ending journey for companies, especially those with global processes, as they must complete with other regional, national and global companies. Another important factor in determining the reliability of a product is the understanding of the critical customer requirements. Due to market globalization, consumers now have access to a greater variety of products and are better able to make comparisons between similar items. This ability drives consumers to constantly change or refine their critical requirements that ultimately influence their purchasing decisions. This case study presents an analysis of a process for monitoring product non-conformances and proposes process improvements aimed at speeding up the solution to field problems. To do this, company reliability will be analyzed in terms of the path of communication of product problems from the customer to the dealer, the dealer to the factory and from the factory to the methodology used to analyze field failures. Information from the product support and services area will be fundamental to the introduction of improvements to the current field failure processes.
3

Validade, reprodutibilidade, sensibilidade e construção de tabela normativa do frequency speed of kick test para o taekwondo / Validity, reliability, sensitivity and construction of normative table of the frequency speed of kick test for taekwondo

Santos, Jonatas Ferreira da Silva 04 April 2018 (has links)
O objetivo do presente estudo foi estabelecer os critérios de autenticidade científica de validade, reprodutibilidade e a sensibilidade do FSKT10s e do FSKTmult para o taekwondo. O objetivo secundário foi construir uma tabela normativa para classificação do desempenho físico gerado no FSKT. O estudo foi conduzido em seis etapas, contendo amostras de praticantes ou atletas de diferentes níveis competitivos. Visando investigar a validade lógica do FSKT, foi apresentado um questionário para 94 sujeitos que tivessem alguma experiência com a modalidade. O objetivo do questionário foi conhecer a opinião a respeito do entendimento sobre as instruções, viabilidade de aplicação e predominância energética. Os participantes julgaram que o teste é \'fácil\' ou \'muito fácil de entender\', \'viável\' ou \'muito viável\' de aplicar e que ambos os testes medem predominantemente a condição anaeróbia. Quanto maior o grau de instrução, maior a frequência de resposta de que o FSKT10s é predominantemente anaeróbio, enquanto para o FSKTmult a maior frequência de resposta no grupo não graduado mede predominantemente a condição aeróbia e o grupo pós-graduado julgou que o teste mede predominantemente a condição anaeróbia. Na etapa seguinte 13 atletas de taekwondo do sexo masculino participaram em duas sessões experimentais para determinar a validade de critério entre a luta e o FSKT. Não foram encontradas associações entre as variáveis da luta e o FSKT. Não foram identificadas diferenças significantes para o lactato pico após FSKTmult e após luta, mas houve diferença estatística entre a luta e o FSKT10s. O objetivo seguinte foi determinar a validade de constructo. Foram avaliados 153 homens agrupados em não competidores (n= 53), competidores de nível regional/estadual (n= 55) e de nível internacional/nacional (n= 45) e 42 mulheres agrupadas em competidoras de nível regional/estadual (n= 21) e de nível internacional/nacional (n= 21). Houve superioridade dos competidores de nível nacional/internacional em comparação aos não competidores. As competidoras de nível regional/estadual diferiram do grupo de nível nacional/internacional. A etapa seguinte foi conduzida com 14 atletas para determinar a reprodutibilidade relativa e absoluta do FSKT em teste e reteste. Para a reprodutibilidade relativa foram observados valores de CCI entre 0,63 e 0,95. O EPM ficou entre 0,60 e 3,99 enquanto o SWC0,6 ficou entre 0,73 e 4,83 para as diferentes séries do FSKT. Na etapa seguinte foi determinada a sensibilidade do FSKT de 8 atletas após nove semanas de treinamento de taekwondo e de força/potência muscular. Foi observada melhora do desempenho gerado em todas as variáveis analisadas, exceto para o índice de decréscimo de chutes (IDC). Por fim, 115 homens e 70 mulheres praticantes/atletas familiarizados com o FSKT executaram cada teste uma vez. Após análise dos dados foi elaborada a tabela com cinco escalas (classificação, percentil: muito bom, >=95; bom, >75; regular, 25-75; ruim, <25; muito ruim, <=5) para as seguintes variáveis FSKT10S, FSKTmult (séries 1-5) e IDC. A conclusão é que o FSKT pode ser uma ferramenta utilizada por técnicos e treinadores visando medir o desempenho físico. Diferentes critérios de autenticidade científica foram apresentados no presente estudo, o que ajudará a tomar decisões mais confiáveis quando de sua aplicação. Também será possível classificar o desempenho dos praticantes/atletas via tabela normativa / The purpose of the present study was stablishing the authenticity criteria scientific of validity, reliability and the sensibility of FSKT10s and the FSKTmult for taekwondo. The secondary purpose was building a normative table to classify physical performance generated by FSKT. The study was conducted in six parts, content sample of practitioners or athletes in different competitive levels. Aiming to investigate the logical validity of FSKT, was presented a questionnaire for 94 subjects that would have any experience with the modality. The purpose was to know the opinion about the understanding of the instructions, feasibility of application and energetic predominance. The participants judged that the test is \"easy\" or \"very easy\", \"viable\" or \"many viable\" of apply and that both tests measure predominantly the anaerobic condition. The higher the level of education, higher is the response frequency of that the FSKT10s is predominantly anaerobic, while for FSKTmult the higher response frequency in the no-graduate group measure predominantly the aerobic condition and the postgraduate group judge that the test measure predominantly the anaerobic condition. In the next step 13 male taekwondo athletes participated in twice experimental sessions to determine a validity criterion between match and the FSKT. No associations were found between match variables and FSKT. No statistically significant difference were identified for the peak blood lactate concentration post FSKT and match, but there was statistical difference between the match and FSKT10s. the next objective was to determine the construct validity. 153 subjects were evaluated grouped in non-competitors (n= 53), regional/state competitors (n= 55) and national/international competitors (n= 45) and 42 women grouped in regional/state level competitors (n= 21) and international/national level (n= 21). There was a statistically significant difference with the superiority of national/international competitors compared to non-competitors. The regional/state level competitors differed from the national/international level group. The next step was conducted with 14 athletes to determine the relative and absolute reliability of FSKT test-retest. Regarding relative reliability, ICC values between 0.63 and 0.95 were observed. The EPM was between 0.60 and 3.99 while the SWC0.6 was between 0.73 and 4.83 for the different FSKT series. The next step was to determine the sensitivity of the FSKT of 8 athletes after nine weeks of taekwondo and strength training. It was observed an improvement in the performance generated in all variables analyzed except for the kicks decrement index (KDI). Finally, 115 mens and 70 womens practitioners/athletes familiar with the FSKT performed each test once. After analyzing the data, the table was elaborated with five scales (classification: \'Excellent\': >=95th percentile, \'Good\': 75th percentile up to 94th percentile, \'Regular\': 25th percentile up to 74th percentile, \'Poor\': 6th percentile up to 24th percentile, \'Very poor\': <=5th percentile) for the following variables FSKT10S, FSKTmult (series 1-5 and total) and IDC. The conclusion is that the FSKT can be a tool used by coaches and technicians to measure physical performance. Different criteria of scientific authenticity were presented in the present study, which will help to make more reliable decisions. It will also be possible to classify the performance of the practitioners/athletes, based on the classifications of the normative table
4

QTLs associados com emocionalidade em fêmeas pósparto de camundongos LG/J x SM/J

Monte, Bruno Gabriel Oliveira do 14 February 2012 (has links)
Made available in DSpace on 2016-06-02T20:21:28Z (GMT). No. of bitstreams: 1 4203.pdf: 1547039 bytes, checksum: fbfd6a9b5b93509ee40ca815bcf3a07b (MD5) Previous issue date: 2012-02-14 / Financiadora de Estudos e Projetos / In mammals, newborns need parental care, mostly maternal care, to succeed in development. Mother emotionality may affect development at initial stages or even emotionality of the offspring in adulthood. In the present study we investigate emotionality, in maternal period, by performing the open field test in mice females from SM/J, LG/J inbred lines and generations F1 and F2 from this intercross. F2 females were also tested in nonmaternal phase. We investigate if F2 females emotionality was associated with variation in weight gain and offspring viability. Finally, we perform QTLs analysis (Quantitative Trait Loci) aiming to study genetic architecture of emotionality at postpartum phase. Ethological analysis indicates that LG/J females seem to have higher level of anxiety when compared to SM/J females. F1 and F2 generations did not show significant differences in most of the phenotypes analyzed. In the contrast between maternal and non-maternal phases of F2 females, it seems females were less anxious in non-maternal phase. In the relationship between anxiety and weight gain among F2 females we observed that several ethological data show significant association with weight gain in some period of life of these females. However, the ethological variations do not seem to interfere in the offspring survival. QTL analysis revealed 11 individual QTLs associated to the phenotypes grooming, immobility, activity at center, and motor activity, that accounts between 5 and 9% of emotionality variation. Beside individual QTLs, we found a total of 88 epistatic QTLs involving the five evaluated phenotypes that together with the individual QTLs explain 24 to 53% of emotionality variation in postpartum females. The present study allowed the identification of putative candidate genes, as well as their relative size effects and patterns of gene action affecting mice emotionality. These results reveal that genetic architecture of emotionality of LG/J x SM/J dams is complex, since indicate the existence of many genes, including the interaction among them in a complex network of epistasis. Besides the genetic basis, is worth noted that environment also have a important impact in emotions through epigenetic mechanisms. / Em mamíferos, filhotes recém-nascidos necessitam de cuidados para que tenham sucesso em seu desenvolvimento. Esse sucesso está diretamente relacionado ao cuidado materno, cujas alterações na emocionalidade da mãe podem afetar o desenvolvimento dos filhotes nos estágios iniciais ou mesmo a própria emocionalidade dos filhotes na idade adulta. No presente estudo investigamos a emocionalidade no período materno, utilizando o teste de campo aberto, em fêmeas de camundongos SM/J, LG/J e gerações F1 e F2 deste intercruzamento, sendo a última também testada para fase não materna. Também averiguamos se a emocionalidade em fêmeas F2 estava associada com a variação do ganho em peso nestas fêmeas e com a viabilidade de sua progênie. Finalmente, utilizamos a análise de QTLs (Quantitative Trait Loci) com o intuito de estudar a arquitetura genética da emocionalidade na fase pós-parto. A análise etológica revela indícios de que fêmeas LG/J apresentam um maior nível de ansiedade quando comparadas com fêmeas SM/J. As gerações F1 e F2 não apresentaram diferenças significativas na maioria dos fenótipos analisados e no contraste entre fase materna e não materna para fêmeas F2, as últimas parecem ser menos ansiosa que as primeiras. Na relação entre ansiedade e ganho em peso entre as fêmeas F2, verificamos que vários dados etológicos estão significativamente associados com o ganho em peso em algum período da vida destas fêmeas. No entanto, as variações etológicas parecem não interferir na sobrevivência da progênie. A análise de QTL revelou 11 QTLs individuais associados aos fenótipos groming, imobilidade, atividade no centro e atividade motora, que respondem entre 5 a 9% da variação de emocionalidade. Além dos QTLs individuais, encontramos um total de 76 QTLs epistáticos envolvendo os cinco fenótipos avaliados, que juntamente com os QTLs individuais explicam de 24 a 53 % da variação de emocionalidade em fêmeas pós-parto. Este estudo permitiu a identificação de potenciais genes candidato, bem como o tamanho relativo dos efeitos do gene e os padrões de ação gênica afetando emocionalidade em camundongos. Esses resultados revelam que a arquitetura genética da emocionalidade de mães LG/J x SM/J é complexa, pois indica a existência de muitos genes, incluindo as interações entre eles em uma complexa rede de epistasia. Além da base genética, vale ressaltar que o ambiente também pode apresentar um grande impacto nas emoções por meio de mecanismos epigenéticos.
5

Validade, reprodutibilidade, sensibilidade e construção de tabela normativa do frequency speed of kick test para o taekwondo / Validity, reliability, sensitivity and construction of normative table of the frequency speed of kick test for taekwondo

Jonatas Ferreira da Silva Santos 04 April 2018 (has links)
O objetivo do presente estudo foi estabelecer os critérios de autenticidade científica de validade, reprodutibilidade e a sensibilidade do FSKT10s e do FSKTmult para o taekwondo. O objetivo secundário foi construir uma tabela normativa para classificação do desempenho físico gerado no FSKT. O estudo foi conduzido em seis etapas, contendo amostras de praticantes ou atletas de diferentes níveis competitivos. Visando investigar a validade lógica do FSKT, foi apresentado um questionário para 94 sujeitos que tivessem alguma experiência com a modalidade. O objetivo do questionário foi conhecer a opinião a respeito do entendimento sobre as instruções, viabilidade de aplicação e predominância energética. Os participantes julgaram que o teste é \'fácil\' ou \'muito fácil de entender\', \'viável\' ou \'muito viável\' de aplicar e que ambos os testes medem predominantemente a condição anaeróbia. Quanto maior o grau de instrução, maior a frequência de resposta de que o FSKT10s é predominantemente anaeróbio, enquanto para o FSKTmult a maior frequência de resposta no grupo não graduado mede predominantemente a condição aeróbia e o grupo pós-graduado julgou que o teste mede predominantemente a condição anaeróbia. Na etapa seguinte 13 atletas de taekwondo do sexo masculino participaram em duas sessões experimentais para determinar a validade de critério entre a luta e o FSKT. Não foram encontradas associações entre as variáveis da luta e o FSKT. Não foram identificadas diferenças significantes para o lactato pico após FSKTmult e após luta, mas houve diferença estatística entre a luta e o FSKT10s. O objetivo seguinte foi determinar a validade de constructo. Foram avaliados 153 homens agrupados em não competidores (n= 53), competidores de nível regional/estadual (n= 55) e de nível internacional/nacional (n= 45) e 42 mulheres agrupadas em competidoras de nível regional/estadual (n= 21) e de nível internacional/nacional (n= 21). Houve superioridade dos competidores de nível nacional/internacional em comparação aos não competidores. As competidoras de nível regional/estadual diferiram do grupo de nível nacional/internacional. A etapa seguinte foi conduzida com 14 atletas para determinar a reprodutibilidade relativa e absoluta do FSKT em teste e reteste. Para a reprodutibilidade relativa foram observados valores de CCI entre 0,63 e 0,95. O EPM ficou entre 0,60 e 3,99 enquanto o SWC0,6 ficou entre 0,73 e 4,83 para as diferentes séries do FSKT. Na etapa seguinte foi determinada a sensibilidade do FSKT de 8 atletas após nove semanas de treinamento de taekwondo e de força/potência muscular. Foi observada melhora do desempenho gerado em todas as variáveis analisadas, exceto para o índice de decréscimo de chutes (IDC). Por fim, 115 homens e 70 mulheres praticantes/atletas familiarizados com o FSKT executaram cada teste uma vez. Após análise dos dados foi elaborada a tabela com cinco escalas (classificação, percentil: muito bom, >=95; bom, >75; regular, 25-75; ruim, <25; muito ruim, <=5) para as seguintes variáveis FSKT10S, FSKTmult (séries 1-5) e IDC. A conclusão é que o FSKT pode ser uma ferramenta utilizada por técnicos e treinadores visando medir o desempenho físico. Diferentes critérios de autenticidade científica foram apresentados no presente estudo, o que ajudará a tomar decisões mais confiáveis quando de sua aplicação. Também será possível classificar o desempenho dos praticantes/atletas via tabela normativa / The purpose of the present study was stablishing the authenticity criteria scientific of validity, reliability and the sensibility of FSKT10s and the FSKTmult for taekwondo. The secondary purpose was building a normative table to classify physical performance generated by FSKT. The study was conducted in six parts, content sample of practitioners or athletes in different competitive levels. Aiming to investigate the logical validity of FSKT, was presented a questionnaire for 94 subjects that would have any experience with the modality. The purpose was to know the opinion about the understanding of the instructions, feasibility of application and energetic predominance. The participants judged that the test is \"easy\" or \"very easy\", \"viable\" or \"many viable\" of apply and that both tests measure predominantly the anaerobic condition. The higher the level of education, higher is the response frequency of that the FSKT10s is predominantly anaerobic, while for FSKTmult the higher response frequency in the no-graduate group measure predominantly the aerobic condition and the postgraduate group judge that the test measure predominantly the anaerobic condition. In the next step 13 male taekwondo athletes participated in twice experimental sessions to determine a validity criterion between match and the FSKT. No associations were found between match variables and FSKT. No statistically significant difference were identified for the peak blood lactate concentration post FSKT and match, but there was statistical difference between the match and FSKT10s. the next objective was to determine the construct validity. 153 subjects were evaluated grouped in non-competitors (n= 53), regional/state competitors (n= 55) and national/international competitors (n= 45) and 42 women grouped in regional/state level competitors (n= 21) and international/national level (n= 21). There was a statistically significant difference with the superiority of national/international competitors compared to non-competitors. The regional/state level competitors differed from the national/international level group. The next step was conducted with 14 athletes to determine the relative and absolute reliability of FSKT test-retest. Regarding relative reliability, ICC values between 0.63 and 0.95 were observed. The EPM was between 0.60 and 3.99 while the SWC0.6 was between 0.73 and 4.83 for the different FSKT series. The next step was to determine the sensitivity of the FSKT of 8 athletes after nine weeks of taekwondo and strength training. It was observed an improvement in the performance generated in all variables analyzed except for the kicks decrement index (KDI). Finally, 115 mens and 70 womens practitioners/athletes familiar with the FSKT performed each test once. After analyzing the data, the table was elaborated with five scales (classification: \'Excellent\': >=95th percentile, \'Good\': 75th percentile up to 94th percentile, \'Regular\': 25th percentile up to 74th percentile, \'Poor\': 6th percentile up to 24th percentile, \'Very poor\': <=5th percentile) for the following variables FSKT10S, FSKTmult (series 1-5 and total) and IDC. The conclusion is that the FSKT can be a tool used by coaches and technicians to measure physical performance. Different criteria of scientific authenticity were presented in the present study, which will help to make more reliable decisions. It will also be possible to classify the performance of the practitioners/athletes, based on the classifications of the normative table
6

Efeito do carvacrol sobre larvas de ​Rhipicephalus microplus ​ (Acari: Ixodidae) em condições seminaturais e citogenotoxidade sobre Brachiaria ruziziensis ​ R.​ Germ & Evrard (Poaceae)

Muniz, Natália Cunha 04 May 2018 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2018-08-14T14:20:32Z No. of bitstreams: 1 nataliacunhamuniz.pdf: 1125755 bytes, checksum: efe31dd995cd852cbe9d452697e12f67 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2018-09-03T16:32:10Z (GMT) No. of bitstreams: 1 nataliacunhamuniz.pdf: 1125755 bytes, checksum: efe31dd995cd852cbe9d452697e12f67 (MD5) / Made available in DSpace on 2018-09-03T16:32:10Z (GMT). No. of bitstreams: 1 nataliacunhamuniz.pdf: 1125755 bytes, checksum: efe31dd995cd852cbe9d452697e12f67 (MD5) Previous issue date: 2018-05-04 / O objetivo desse trabalho foi avaliar a atividade carrapaticida do carvacrol sobre larvas de Rhipicephalus microplus em lâminas foliares de Brachiaria ruziziensis, bem como a genotoxicidade desta solução sobre esta espécie de gramínea . Soluções de carvacrol em concentrações de 1,25; 2,50; 5,00; 10,00 e 20,00 mg/mL foram aspergidas em vasos que haviam recebido larvas não alimentadas de R. microplus. Após um período de 24h da aplicação, foram contabilizados os sobreviventes e calculada a eficiência de cada tratamento. Nas menores concentrações, os percentuais de eficiência foram semelhantes ao grupo controle, enquanto nas maiores concentrações, 10,00 e 20,00 mg/ml, a eficiência do tratamento foi de 89,84% e 94.66%, respectivamente. Na avaliação de genotoxicidade de B. ruziziensis , feita por análise de citometria de fluxo, foram observados danos celulares de até 100%. Portanto, é possível concluir que o carvacrol é uma alternativa no controle de carrapatos, visando a redução da utilização de produtos químicos. / The aim of this study was to evaluate an acaricide activity of carvacrol on larvae of Rhipicephalus microplus in leaf blades of Brachiaria ruziziensis and the genotoxicity of this solution on this species of grass. Carvacrol solutions in concentrations of 1,25; 2,50; 5,00; 10,00 e 20,00 mg/mL were sprayed on vessels that had previously received non-fed R. microplus larvae. After a 24-hour application period, the survivors were accounted for and the efficiency of each treatment was calculated. At the lowest concentrations, the efficiency percentages were similar to those of the control, while at the highest concentrations, 10.00 and 20.00 mg/mL, the treatment efficiency was 89.84% and 94.66%, respectively. In the evaluation of genotoxicity of B. ruziziensis , made by flow cytometric analysis, cellular damage up to 100% was observed. Therefore, it is possible to conclude that carvacrol is an alternative in the control of ticks, aiming to reduce the use of chemicals.
7

Comparação das respostas fisiológicas entre dois testes de carga constante: cicloergômetro e degrau / Comparison of the physiological responses between two constant load tests: cyclo ergometer and step

Rodrigues Junior, José Carlos 15 December 2017 (has links)
Submitted by Nadir Basilio (nadirsb@uninove.br) on 2018-07-19T17:29:15Z No. of bitstreams: 1 José Carlos Rodrigues Junior.pdf: 971813 bytes, checksum: 62c2be1a3750c4ab8d2efb12f062e157 (MD5) / Made available in DSpace on 2018-07-19T17:29:15Z (GMT). No. of bitstreams: 1 José Carlos Rodrigues Junior.pdf: 971813 bytes, checksum: 62c2be1a3750c4ab8d2efb12f062e157 (MD5) Previous issue date: 2017-12-15 / Introduction: The six-minute walk test (TC6) and shuttle walk test (SWT) are widely used for the assessment of functional capacity in patients with chronic obstructive pulmonary disease (COPD), however their execution may be limited by physical space. In this context, the step test has the facility of being able to be applied in any environment, including the home. However, there are no studies in the literature with constant load tests using the step and its physiological responses. Objectives: 1) to compare the physiological responses between the constant load tests on the cycle ergometer and the endurance step test 2) to establish the determinants of the performance obtained in the TDE, 3) to test the reproducibility of the TDE. Method: 19 patients with COPD performed spirometry, incremental and constant load test on cycle ergometer, bioimpedance to obtain muscle mass and incremental step test (TDI), responded to the Modified Medical Research Council modified dyspnea scale (MRCm) and the Saint George's Respiratory Questionnaire (SGRQ). Leg length was also evaluated and a maximal repetition test was performed. The TDE was performed with 80% of the number of steps obtained in the TDI. This should last for three to eight minutes. If the test time was less than three minutes, the TDE was again performed with 70% of the number of TDI steps. If the TDE was greater than eight minutes, the TDE was performed with a 90% load. Results: there was no difference between the metabolic and ventilatory responses between the TDE and the constant load test in cycle ergometer. No correlation was found between the performance of the TDE with the degree of airway obstruction, mass and quadriceps muscle strength. The time of TDE 90% was shown to be better reproducible compared to TDE 80%. Conclusion: the endurance step test provokes metabolic and ventilatory responses equated to the constant load test on cycle ergometer. / Introdução: O teste de caminhada de seis minutos (TC6) e o shuttle walk test (SWT) são vastamente utilizados para a avaliação da capacidade funcional em pacientes com doença pulmonar obstrutiva crônica (DPOC), entretanto sua execução pode ser limitada pelo espaço físico. Nesse contexto, o teste do degrau possui a facilidade de poder ser aplicado em qualquer ambiente, inclusive o domiciliar. Entretanto, não há na literatura estudos com testes de carga constante utilizando o degrau e suas respostas fisiológicas. Objetivos: 1) comparar as respostas fisiológicas entre os testes de carga constante no cicloergômetro e no teste do degrau endurance (TDE) 2) estabelecer os determinantes do desempenho obtido no TDE, 3) testar a reprodutibilidade do TDE. Método: 19 pacientes com diagnóstico de DPOC realizaram espirometria, teste incremental e de carga constante em cicloergômetro, bioimpedância para obtenção da massa muscular e o teste do degrau incremental (TDI), responderam à escala de dispneia Medical Research Council modificada (MRCm) modificada, e ao Saint George’s Respiratory Questionnaire (SGRQ). Também foi avaliado o comprimento de perna e realizado o teste de uma repetição máxima. O TDE foi realizado com 80% do número de degraus obtido no TDI. Este deverá ter uma duração de três a oito minutos. Caso o tempo do teste fosse menor do que três minutos, o TDE foi novamente realizado com 70% do número de degraus do TDI. Caso o TDE fosse superior a oito minutos, o TDE foi realizado com a carga de 90%. Resultados: não houve diferença entre as respostas metabólicas e ventilatórias entre o TDE e o teste de carga constante em ciclo ergômetro. Não foi encontrada correlação entre o desempenho do TDE com o grau de obstrução de vias aéreas, massa e força muscular de quadríceps. O tempo do TDE 90% mostrou-se com melhor reprodutibilidade, em comparação ao TDE 80%. Conclusão: o teste do degrau endurance provoca respostas metabólicas e ventilatórias equiparadas ao teste de carga constante em cicloergômetro.
8

Exercício agudo realizado a baixo ou acima do limiar anaeróbio induz diferentes comportamentos de ansiedade em ratos wistar

Lima, Carleuza Francisca de 28 June 2007 (has links)
Made available in DSpace on 2016-06-24T04:15:39Z (GMT). No. of bitstreams: 1 Texto Completo.pdf: 1087367 bytes, checksum: 37433b8a928cf0b32aadd085b4260bfe (MD5) Previous issue date: 2007-06-28 / Few studies have investigated the acute/chronic effects of physical exercises on behaviors related to anxiety in animal models and the results are quite contradictory. Those conflicts seem to result from the methodological diversity among the studies, for example, the configuration of the physical exercise program. Materials and methods. Male Wistar rats were randomly divided in 4 groups: Control, 0, 5 or 50% of the body weight. The effect of the intensity of the swimming exercise on the behavioral measurements in the tests of elevated plus-maze and open field were investigated. Results. The variance analysis revealed significant differences on the concentration of blood lactate among the groups (p < 0.01). The analyses revealed that the 50% group showed smaller stay time and entrance in the open arms of the maze compared to the Control one, and to the groups of 0% and 5% of body weight. The animals submitted to a smaller level of physical stress revealed a higher disposition - up to 54% - to stay in the open arms when compared with the Control group. Conclusions. The results suggest that the acute effects of the physical exercise result in complex and transitory changes of behavior and central neurochemistry in rats. Those changes seem to follow a charge-response ratio that depends on the intensity of the exercise. / Poucos trabalhos têm investigado os efeitos agudos/crônicos do exercício físico sobre o comportamento relacionado com a ansiedade em modelo animal e os resultados são bastante contraditórios. Esses conflitos parecem decorrentes da diversidade metodológica entre os trabalhos, por exemplo, a configuração do programa de exercício físico. Materiais e métodos. Ratos machos Wistar foram aleatoriamente divididos em 4 grupos: Controle, 0, 5 ou 50% do peso corporal. O efeito da intensidade do exercício de natação sobre medidas de comportamento nos testes de labirinto em cruz elevado e de campo aberto foi investigado. Resultados. A análise de variância revelou diferenças significativas sobre a concentração de lactato sangüíneo entre os grupos (p < 0,01). As análises revelaram que o grupo 50% apresentou menor tempo de permanência e entradas nos braços abertos do labirinto em relação ao Controle e aos grupos de 0% e 5% do peso corporal. Os animais submetidos a menor carga de estresse físico revelaram uma disposição em até 54% maior para permanecer nos braços abertos quando comparada ao Controle. Conclusões. Os resultados sugerem que os efeitos agudos do exercício físico proporcionam complexas e transitórias alterações sobre o comportamento e a neuroquímica central em ratos. Essas alterações parecem obedecer a uma relação dose-resposta dependente da intensidade do exercício.
9

Variáveis laboratoriais, desempenho e pacing no ciclismo contra-relógio de 20 minutos realizado em subida

Bossi, Arthur Henrique Souza Neto 22 August 2014 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-06-22T14:27:00Z No. of bitstreams: 1 arthurhenriquesouzanetobossi.pdf: 861040 bytes, checksum: c3c1cec3feee16cacb22f14eb9d27f1c (MD5) / Rejected by Adriana Oliveira (adriana.oliveira@ufjf.edu.br), reason: on 2017-06-22T14:35:05Z (GMT) / Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-06-22T14:39:20Z No. of bitstreams: 1 arthurhenriquesouzanetobossi.pdf: 861040 bytes, checksum: c3c1cec3feee16cacb22f14eb9d27f1c (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-08-07T19:21:44Z (GMT) No. of bitstreams: 1 arthurhenriquesouzanetobossi.pdf: 861040 bytes, checksum: c3c1cec3feee16cacb22f14eb9d27f1c (MD5) / Made available in DSpace on 2017-08-07T19:21:44Z (GMT). No. of bitstreams: 1 arthurhenriquesouzanetobossi.pdf: 861040 bytes, checksum: c3c1cec3feee16cacb22f14eb9d27f1c (MD5) Previous issue date: 2014-08-22 / Para maior empregabilidade do protocolo de teste contra-relógio (CR) de 20 min em campo, é necessária a compreensão (1) de como o desempenho em percurso de subida se relaciona com as medidas laboratoriais típicas e (2) do perfil de pacing adotado. Separados por pelo menos 48 horas, 15 ciclistas moderadamente treinados, incluindo 1 do sexo feminino (30,8±4,8 anos; 176,5±8,0 cm; 78,9±14,5 kg; 56,1±7,7 ml.kg-1.min-1; média ± desvio padrão), realizaram inicialmente um teste anaeróbio Wingate, um teste de esforço incremental até a exaustão e um contrarelógio de campo por 20 min em percurso de subida com 2,7% de inclinação média. Após 5 semanas de treinamento não supervisionado, 10 dos 15 voluntários realizaram um segundo CR para comparação do pacing adotado. As regressões lineares múltiplas stepwise demonstraram que 91% da variação na potência média produzida no CR (W.kg-1) pode ser explicada pelo pico do consumo de oxigênio (ml.kg-1.min-1) e pelo ponto de compensação respiratória (W.kg-1), com coeficientes beta padronizados de 0,64 e 0,39 respectivamente. A realização do CR em aclive pressupõe um ajuste de 94,6% da potência média, de modo a aperfeiçoar a concordância com a potência referente ao ponto de compensação respiratória, em que o diagrama de Bland-Altman demonstrou um viés ± erro aleatório de 0,4±49,7 W ou -0,1±19,7 %. A ANOVA two-way (CR X tempo) para medidas repetidas revelou efeito principal dos intervalos de tempo (p < 0,001) na potência média produzida em cada trecho (122,2±10,0; 97,8±1,2 e 95,1±7,1% para os trechos 0-2, 2-18 e 18-20 min, respectivamente) caracterizando perfil de pacing positivo, tanto no primeiro, quanto no segundo teste (p = 0,116). Em conjunto, estas informações indicam que o protocolo de teste CR de 20 min realizado em subida, aparentemente, seja robusto para monitorar o desempenho de ciclistas de diferentes níveis competitivos. Entretanto, novos estudos mais específicos são importantes para confirmar a reprodutibilidade do desempenho e para verificar a influência do feedback instantâneo da potência produzida. / For a wider applicability of the 20-min time trial (TT) testing protocol in field, it is necessary to understand (1) how performance in an uphill course relates with typical laboratory measures and (2) the pacing profile adopted. Separated by at least 48 hours, 15 moderately trained cyclists, including 1 female (30.8±4.8 years; 176.5±8.0 cm; 78.9±14.5 kg; 56.1±7.7 ml.kg-1.min-1; mean ± standard deviation), initially performed a Wingate anaerobic test, a graded exercise test to exhaustion and a 20-min field time trial in a 2.7% gradient uphill course. After 5 weeks of nonsupervised training, 10 from 15 volunteers performed a second TT for comparison of the pacing adopted. Stepwise multiple linear regressions demonstrated that 91% of TT mean power output variation (W.kg-1) can be explained by peak oxygen consumption (ml.kg-1.min-1) and respiratory compensation point (W.kg-1), with standardized beta coefficients of 0.64 and 0.39 respectively. Performing TT on ascents premises a 94.6% mean power output adjustment in order to improve the agreement with respiratory compensation point power output, which Bland-Altman plot showed a bias ± random error of 0.4±49.7 W or -0.1±19.7 %. Repeated measures two-way ANOVA (TT X time) revealed a main effect of the time intervals (p < 0.001) on the power output of each portion (122.2±10.0; 97.8±1.2 e 95.1±7.1% for the portions 0-2, 2-18 e 18-20 min, respectively) characterizing a positive pacing profile, either in the first and in the second test (p = 0.116). Together, this information indicates that the 20-min TT testing protocol performed on ascent is apparently robust for performance monitoring of different competitive level cyclists. However, more specific new studies are important to confirm performance reproducibility and to verify the influence of power output instant feedback.
10

Avaliação das atividades locomotora e nociceptiva diárias e sazonais de lagartos mantidos em condições ambientais controladas / Evaluation of daily and seasonal locomotor and nociceptive activities of lizards under controled environmental conditions

Bisetto, Shayne Pedrozo 15 December 2016 (has links)
O uso de répteis como modelos experimentais é limitado, principalmente devido às particularidades fisiológicas da classe, como as oscilações diárias e sazonais em seu comportamento. O objetivo deste estudo foi avaliar a atividade locomotora e nociceptiva de teiús (Salvator merianae) e iguanas-verdes (Iguana iguana) submetidos a testes comportamentais, ao longo do dia e do ano. Foram utilizados seis exemplares de cada espécie, mantidos em sala com temperatura ambiental (24 a 30°C) e fotoperíodo (12h:12h) controlados. Esses foram avaliados ao longo do dia (0:00h, 6:00h, 12:00h, 18:00h) e ao longo do ano (análise mensal). A análise locomotora foi realizada através do teste de campo aberto (teiús e iguanas), no qual o animal foi colocado no centro de uma arena circular por 15 minutos, e recebeu um ponto por cada ultrapassagem pelas subdivisões da mesma; e pelo teste de natação forçada (iguanas), no qual o tempo de atividade foi mensurado em piscina sem saída por 2 minutos. A resposta nociceptiva foi avaliada por meio de mensuração do período de latência do membro em resposta a estímulo nocivo térmico (25 segundos; 245 ± 7 mW/cm2) na superfície plantar do membro do animal. Não foram detectadas oscilações ao longo do ano no teste de campo aberto em nenhuma das espécies. Ao longo do dia, oscilações foram detectadas de Fevereiro a Dezembro em teiús; e em Abril, Maio, Junho e Outubro em iguanas. O tempo de atividade das iguanas foi menor em Janeiro e às 0:00h. Maiores latências de retirada do membro foram observadas nos meses de Maio e Agosto e às 6:00h em ambas espécies. Conclue-se que teiús e iguanas-verdes em ambiente controlado apresentam oscilações significativas em comportamento observado em teste de campo aberto, teste de natação forçada (somente iguanas) e teste plantar, que aparentemente não seguem padrões anuais claros, sendo provavelmente influenciado por fatores múltiplos ainda não compreendidos para as espécies. / The use of reptiles as experimental models is limited due to their physiological particularities, such as daily and annual fluctuations in behavior. The aim of this study was to evaluate locomotor and nociceptive activities of tegus (Salvator merianae) and green iguanas (Iguana iguana) throughout the day and the year, when undergoing behavioral tests. Six animals from each species, kept under controlled room temperature (24 to 30°C) and photoperiod (12h:12h), were used. They were evaluated throughout the day (0:00h, 6:00h, 12:00h and 18:00) and the year (monthly). Locomotor activity was measured by the open field test, in which the animal was placed in the center of a round arena for 15 minutes and the number of crossings through the subdivisions of the arena was counted, and by the forced swim test (iguanas), in which the activity period was timed after animals were placed in a pool with no scape for 2 minutes. Nociceptive activity was measured as the latency to limb withdrawal reflex in response to a noxious thermal stimulus (25 seconds, 245 ± 7 mW/cm2) in the plantar surface of the animal\'s limb. No differences were detected in locomotor activity in the open field test throughout the year in both species. Throughout the day, fluctuations were detected from February to December in tegus, and in April, May, June and October in iguanas. Activity period in iguanas were shorter in January and at 0:00h. Longer latencies to withdrawal reflex were detected in May and August and at 6:00h in both species. In conclusion, tegus and green iguanas kept in controlled environment have fluctuations in behavior presented in the open field test, the forced swim (only iguanas) test and the plantar test, which apparently do not follow a clear seasonal pattern and are probably influenced by multiple factors that are still unknown for both species.

Page generated in 0.0558 seconds