• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 882
  • 11
  • 11
  • 11
  • 9
  • 6
  • 5
  • 4
  • 4
  • 4
  • 3
  • 3
  • 2
  • 1
  • 1
  • Tagged with
  • 899
  • 385
  • 248
  • 164
  • 112
  • 112
  • 91
  • 84
  • 72
  • 71
  • 63
  • 60
  • 60
  • 60
  • 58
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
191

Relação entre a dilatação mediada pelo fluxo da artéria braquial medida através da ultrassonografia com Doppler e risco cardiovascular em pacientes com Diabetes tipo 2

Kasmirscki, Cristine January 2015 (has links)
A disfunção endotelial refere-se à alteração da vasodilatação dependente do endotélio e à má regulação da interação endotélio - células sanguíneas, o que gera uma inflamação localizada e, posteriormente, lesões vasculares graves e trombose. Geralmente ocorre antes das manifestações estruturais e a sua avaliação clínica pode servir como preditor de eventos cardiovasculares futuros, sendo um marcador precoce da atividade da doença aterosclerótica. O objetivo do presente manuscrito foi revisar aspectos relacionados à fisiopatologia da disfunção endotelial, os métodos empregados na sua avaliação e a relação com os desfechos cardiovasculares. Trata-se de uma revisão bibliográfica, para a qual foram selecionados artigos publicados em inglês e português na base de dados Pubmed utilizando termos de indexação relacionados ao tema de interesse: disfunção endotelial. A partir desta busca a revisão foi estruturada em quatro partes: 1. Fisiopatologia da disfunção endotelial; 2. Métodos de avaliação da função endotelial; 3. Relação entre Disfunção Endotelial e Desfechos Cardiovasculares; 4. Avaliação da função endotelial na prática clínica. Com este estudo, conclui-se que a aplicabilidade da avaliação da função endotelial na prática clínica carece da padronização de um método que seja prático, de baixo custo e que apresente boa reprodutibilidade, além do estabelecimento de pontos de corte específicos para as diferentes populações. As evidências científicas sugerem que a alteração na função endotelial ocorre bem antes das manifestações clínicas e das alterações vasculares e sua avaliação clínica pode servir como preditor de eventos cardiovasculares.
192

Características ultrassonográficas e risco de câncer de tireoide : revisão sistemática e meta-análise de estudos observacionais

Remonti, Luciana Loss Reck January 2013 (has links)
Introdução: nódulos de tireoide são uma anormalidade comum podendo ser encontrados em até 70% da população com o uso de ultrassonografia de alta resolução. As características ecográficas dos nódulos são tradicionalmente utilizadas como critérios de risco para malignidade, porém sua acurácia diagnóstica é bastante variável na literatura. Objetivo: avaliar a performance diagnóstica das características ultrassonográficas para carcinoma de tireoide em nódulos não selecionados e naqueles com citologia não diagnóstica na punção aspirativa com agulha fina. Desenho do estudo: revisão sistemática e meta-análise de estudos observacionais Bases de dados: bancos de dados eletrônicos (Medline, Embase) até Julho de 2012 além de busca manual nas referências dos principais estudos, artigos de revisão e meta-análises prévias Critérios de Elegibilidade: estudos que tenham avaliado características ultrassonográficas de nódulos de tireoide e que reportem o exame histopatológico como diagnóstico final. Uma meta-análise em separado foi realizada com os estudos que incluíram apenas nódulos com citologia não diagnóstica (insatisfatória ou indeterminada). As características analisadas foram: ser sólido, hipoecogenicidade, margens irregulares, ausência de halo, presença de microcalcificações, vascularização central, ser solitário, heterogeneidade, formato mais alto do que largo e ausência de elasticidade. Resultados: 52 estudos observacionais (12786 nódulos) foram incluídos. Onze estudos avaliaram apenas nódulos com citologia não diagnóstica, compreendendo 2338 nódulos. Todas as características avaliadas foram significativamente associadas a malignidade com Razão de Chances (RC) variando de 1,78 a 35,7. Presença de microcalcificações, margens irregulares e uma formato mais alto do que largo apresentaram alta especificidade (87,8%, 83,1%, 96,6%) e Razão de Verossimilhança (RV) (3,26, 2,99, 8,07) nos nódulos não selecionados. A presença de microcalcificações foi a característica ultrassonográfica com melhor especificidade (84,4%) e RV positiva (3,01) nos nódulos com citologia não diagnóstica. A ausência de elasticidade foi a característica que, isoladamente, mostrou a melhor performance diagnóstica (sensibilidade de 87,9%, especificidade de 86,2% e RV positiva de 6,39). Conclusão: As características ultrassonográficas avaliadas, isoladamente, não fornecem informações suficientes para selecionar os pacientes que devem ser submetidos a punção aspirativa com agulha fina de tireoide. Nódulos com microcalcificações, margens irregulares, uma formato mais alto do que largo ou ausência de elasticidade demonstraram uma maior probabilidade pós teste para câncer, sugerindo que devem receber manejo mais agressivo. A elastografia é uma técnica promissora, porém mais estudos ainda são necessárias correlacionando seus resultados com o diagnóstico histopatológico, especialmente em nódulos com citologia não diagnóstica.
193

Ultra-sonografia para medir a diátase dos músculos retos do abdome / Ultrasonography for mesuring rectus abdominis muscles diastasis

Mendes, Denise de Almeida [UNIFESP] January 2006 (has links) (PDF)
Made available in DSpace on 2015-12-06T23:44:37Z (GMT). No. of bitstreams: 0 Previous issue date: 2006 / Introdução: Métodos de diagnósticos por imagem podem ser úteis para determinar a posição dos músculos retos do abdome antes de sua correção. Objetivo: avaliar o uso da ultra-sonografia para medir a largura da diástase dos músculos retos do abdome. Métodos: A diástase dos músculos retos do abdome foi medida pela ultra-sonografia, no período pré-operatório em 20 mulheres candidatas à abdominoplastia, por dois examinadores independentes. Seis níveis da bainha anterior dos músculos retos do abdome foram estudados pela ultra-sonografia após inspiração profunda sustentada. A diástase dos músculos retos do abdome, nos mesmos níveis, foi também medida após sua exposição durante a abdominoplastia, por dois observadores independentes, usando compasso cirúrgico. As medidas foram comparadas usando o teste estatístico de Wilcoxon. Resultados: Não houve diferença estatística significante entre as medidas ultra-sonográficas dos dois examinadores nos níveis supra-umbilicais. Houve diferença estatística significante entre as medidas ultra-sonográficas nos níveis do umbigo e infra-umbilical. Conclusão: A ultra-sonografia é um método válido para medir a diástase de retos na região supra-umbilical. / BV UNIFESP: Teses e dissertações
194

Associação da espessura do complexo intimal-medial da artéria carótida com fatores de risco cardiovascular em mulheres pre e pós-cirurgia bariátrica / Association of carotid intima-media thickness and cardiovascular risk factors in women pre and post bariatric surgery

Sarmento, Priscilla Lopes da Fonseca Abrantes [UNIFESP] January 2008 (has links) (PDF)
Made available in DSpace on 2015-12-06T23:47:40Z (GMT). No. of bitstreams: 0 Previous issue date: 2008 / Objetivos: avaliar a influência da perda de peso na espessura do complexo intimalmedial carotídeo (CIM-C) e a variação da espessura do CIM-C de acordo com a modificação dos fatores de risco cardiovascular decorrente da cirurgia bariátrica. Métodos: dezoito mulheres (idade média de 44,1 ± 9,8 anos e o IMC médio de 44,3±6,4 kg/m2 ), submetidas à cirurgia bariátrica, participaram do estudo. As avaliações foram feitas no período basal e após 3,6 e 12 meses de pós-operatório. Os FRCVs analisados foram: nível de colesterol total,nível de lipoproteína de alta densidade do colesterol(HDL-C), relação triglicérides/ HDL-C (TG/HDL-C) conhecido como índice aterogênico do plasma, glicemia de jejum, bem como comorbidades outras como hipertensão arterial e tabagismo. O CIM-C foi medido pelo método não invasivo através da ultra-sonografia modo B. Resultados: na avaliação basal, baixo nível de HDL-C foi encontrado em 55,6%, altos níveis de colesterol total em 50% e altos níveis de triglicérides em 33,4%. Houve correlação significativa entre o CIM-C com a idade e com a trigliceridemia (r =0,67, p=0,002 e r=0,56, p=0,02 respectivamente) Seis meses após a cirurgia, observamos redução significante do CIM-C (p<0,05) que mostrou correlação significativa com a trigliceridemia e com a pressão arterial (p<0,05). Conclusão: os resultados deste estudo sugerem que a perda de peso obtida com a cirurgia bariátrica é acompanhada pela regressão do CIM-C, um marcador precoce da aterosclerose e essa regressão pode ser evidenciada após 6 meses da cirurgia, com benefício adicional em 12 meses. / Purpose: to correlate CIM-C thickness with the CVRFs before the surgery (baseline data) and after the surgery, and to observe whether the weight loss is followed by a regression of CIM-C thickness. Methods: eighteen women (mean age: 44.1 ± 9.8 years and mean BMI: 4.3±6.4kg/m2 ) submitted to bariatric surgery participated in this study. The assessments were performed in the baseline period and 3, 6 and 12 months after the surgery. The analyzed CVRFs were: total cholesterol level; high-density lipoprotein cholesterol (HDL-C) level; relation between triglycerides and HDL-C (TG/HDL-C) - also known as atherogenic index of plasma; fasting glycemia; as well as other comorbidities, such as blood pressure arterial and smoking habit. CIM-C was measured through a non-invasive method: B-mode ultrasound system. Results: in the baseline assessment, low level of HDL-C was found in 55,6%, elevated total cholesterol in 50% and hypertriglyceridemia in 33.4%, and a positive correlation was found between CIM-C and age and triglyceridemia (r =0.67, p=0.002 and r=0.56, p=0.02, respectively). Six months after the surgery, we found a significant reduction of CIM-C (p<0.05), which presented a positive correlation with triglyceridemia and systolic pressure (p<0.05). Conclusion: the results from this study suggest the weight loss achieved through bariatric surgery is followed by the regression of CIM-C, an indicator of early atherosclerosis. This regression may be evidenced 6 months, with additional benefits 12 months after the surgery. / BV UNIFESP: Teses e dissertações
195

Impacto da embolização arterial do leiomioma uterino no volume uterino, diâmetro do mioma dominante e na função ovariana / Impact of the mioma arterial embolization by uterine volume, mioma diameter greater and in the ovarian function

Bernardo, Andre [UNIFESP] 25 May 2011 (has links) (PDF)
Made available in DSpace on 2015-07-22T20:50:19Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-05-25. Added 1 bitstream(s) on 2015-08-11T03:26:06Z : No. of bitstreams: 1 Publico-12634.pdf: 488476 bytes, checksum: 5e0af058b16520b991d17847c830fc84 (MD5) / INTRODUÇÃO: Para avaliar o impacto da embolização arterial de miomas (EAM) no volume uterino, diâmetro do maior mioma e na função ovariana, foi realizado antes e após 3 meses do procedimento ultrassonografia pélvica pela via transvaginal (USPTV) e dosagens de FSH (hormônio folículo estimulante). CASUÍSTICA E MÉTODO: Participaram do estudo 30 pacientes com leiomioma sintomático que se submeteram à EAM após ciência e assinatura do termo de consentimento livre e esclarecido, obedecendo aos critérios de inclusão do estudo. Foram realizados exames de USPTV pelo mesmo profissional, no mesmo aparelho antes e após três meses da EAM. O volume uterino foi expresso em cm³ e o diâmetro do maior mioma em cm. Foram feitas dosagens de FSH antes e após três meses da EAM no laboratório central do Hospital São Paulo. Os valores foram quantificados em UI/ml, analisados e expressos por média±desvio padrão (DP). Os dados foram então submetidos a análise estatística pelo teste não paramétrico de Mann-Whitney. RESULTADOS: Houve a exclusão de uma paciente por falta de dados pós-EAM. A média do volume do útero pré-EAM foi 402,4±165,9cm³, diâmetro do maior mioma pré-EAM 5,928±2,126cm. O resultado observado foi volume uterino pós-EAM foi 258,9±118,6cm³ e diâmetro do maior mioma pós-EAM 4,607±1,858cm. A média da dosagem de FSH pré-EAM foi 4,997(±3,520)UI/ml e pós-EAM foi 5,500(±4,759)UI/ml com p=0,581*. Das dosagens hormonais foram analisados 29 casos. Uma paciente, que equivale a 3,4% do total, cursou com aumento definitivo de FSH. Houve redução de 35% do volume uterino, de 22% no tamanho do maior leiomioma e a EAM não alterou significativamente os valores de FSH após 3 meses. CONCLUSÃO. O procedimento diminuiu o volume uterino e o diâmetro do maior mioma preservando o órgão e, não provoca alterações na função ovariana. / PURPOSE: To evaluate the impact of the mioma arterial embolization (EAM) by uterine volume, mioma diameter greater and in the ovarian function, was carried through before and after three months of the procedure, pelvic ultrasonography for the transvaginal way (USPTV) and dosages of FSH (follicle-stimulating hormone). METHODS: Thirty patients carrying of symptomatic leiomyomas had participated of the study that they had been submitted to the EAM after science and signature of the term of free and clarified assent, obeying the criteria of inclusion of the study. Examinations of USPTV for the same professional had been carried through, in the same device before and after three months of the EAM. The uterus volume was express in cm³ e mioma diameter greater in cm. Had been made dosages of FSH before and after three months of the EAM in the central laboratory of the Hospital São Paulo. The values had been quantified in UI/ml, analyzed and express for medium+/-shunting line standard. The data then had been submitted the statistics analysis for the test distribution free of Mann-Whitney. RESULTS: It had the exclusion of a patient due to lack of data after EAM. The average before EAM uterine volume was 402,4±165,9cm³, before-EAM mioma diameter greater 5,928±2,126cm. The observed result was after-EAM uterine volume was 258,9±118,6cm³ and after-EAM mioma diameter greater 4,607±1,858cm. The average of the dosage before-EAM FSH was 4,997 (±3,520) UI/ml and after-EAM FSH was 5,500 (±4,759) UI/ml with p=0,581*. In hormone dosages, 29 cases had been evaluated. One case, that is equivalent 3.4% of the total, attended a course with definitive increase of FSH. It had reduction of 35% of the uterus volume, of 22% in the size of the mioma diameter greater and the EAM did not modify the FSH values significantly after 3 months. CONCLUSION: The procedure causes reduction of the uterine volume and leiomyomas preserving the uterus and, does not provoke ovarian function alterations. / TEDE / BV UNIFESP: Teses e dissertações
196

Uso prévio de estatina no infarto agudo do miocárdio experimental em ratos : análise de estresse oxidativo 48h pós-insulto associado a parâmetros ecocardiográficos

Dall Alba, Rafael January 2011 (has links)
Resumo não disponível
197

Aparelhos portáteis de ecocardiografia (Handheld devices) : concordâncias e discordâncias em seu uso na prática clínica diária

Blume, Gustavo Gavazzoni January 2016 (has links)
Introdução: Avaliar a aplicabilidade clínica de um novo aparelho portátil de ecocardiografia em ambiente de prática clínica usual e comparar as concordâncias e discordâncias nos laudos elaborados por ecocardiografistas experientes entre os aparelhos usuais e portáteis. Métodos: Estudo prospectivo realizado entre abril e maio de 2016 com pacientes ambulatoriais previamente agendados para realizar exames de ecocardiografia pelos mais diversos motivos. O exame standard (STD) foi realizado de maneira usual primeiramente for sonógrafo experiente e habilitado e posteriormente revisto e laudado pelo ecocardiografista responsável. Os exames rea lizados com o aparelho portátil (HH) foram realizados e laudados diretamente pelo ecocardiografista. Foram incluídos nos exames STD imagens bidimensionais, por colar Doppler e análise hemodinâmica usual. Análise hemodinâmica esta não real izadas nos exames HH pois tal tecnologia não se encontra disponível no dispositivo utilizado. As imagens real izadas pelas duas modalidades foram independentemente avaliadas e laudadas por dois diferentes ecocardiografistas. Concordâncias e discordâncias entre os laudos foram avaliadas. Resultados : Cento e dez pacientes foram incluídos na amostra com idade média entre 62,4 :!: 16,7 anos. A avaliação de concordância por Lin demonstrou uma excelente correlação de 0,86 na avaliação da estimativa visual da fração de ejeção e de 0,84 na estimativa do escore de contratilidade segmentar. O valor de K para a estimativa da disfunção ventricular foi de 0,85, O, 78 para a presença ou ausência de alterações segmentares, 0,6 para a graduação da hipertrofia ventricular, 0,83 para a estimativa do tamanho ventricular direito e 0,82 para a estimativa da função ventricular direita. Analise valvardemonstrou valor κ de 0,42 para a avaliação da regurgitação mitral, 0,56 para regurgitação aórtica, 0,96 para avaliação de estenose mitral e 0,82 para avaliação de estenose aórtica. A concordância para avaliação de insuficiências tricúspide e pulmonar demonstroucse extremamente baixa com valores κ respectivamente de 0,26 e 0,25. Em 50% dos pacientes foram encontrados dados discordantes principalmente secundários a insuficiências valvares!e!avaliação das dimensões atriais. Conclusão:Emambiente similar a pratica clinica diária, em mãos experientes, os exames executados em aparelhos portáteis apresentam boa concordância com as maquinas usuais nas avaliações ventriculares (tamanho e função). Porém achados discordantes foram encontrados em 50% dos pacientes principalmente devido a discordância na avaliação de regurgitações valvares e de dimensões atriais. A disseminação no uso de aparelhos portáteis deve ser feita com ressalvas e cautela mesmo por pessoas experientes.
198

Dimensões da adrenal e quantidade de gordura visceral em cães tratados com prednisona

Lopes, Bernardo Fernandes 25 March 2011 (has links)
Submitted by Maykon Nascimento (maykon.albani@hotmail.com) on 2016-04-29T18:40:05Z No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertacao Bernando Fernandes Lopes.pdf: 548323 bytes, checksum: 122a87023dcca9152a6f9453c4829f3d (MD5) / Approved for entry into archive by Patricia Barros (patricia.barros@ufes.br) on 2016-05-09T18:53:37Z (GMT) No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertacao Bernando Fernandes Lopes.pdf: 548323 bytes, checksum: 122a87023dcca9152a6f9453c4829f3d (MD5) / Made available in DSpace on 2016-05-09T18:53:37Z (GMT). No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertacao Bernando Fernandes Lopes.pdf: 548323 bytes, checksum: 122a87023dcca9152a6f9453c4829f3d (MD5) / Os glicocorticóides são amplamente utilizados na prática clínica, porém importantes efeitos adversos são descritos em cães. Objetivou-se com o presente estudo verificar a influência da prednisona sobre o tamanho da adrenal e na quantidade de gordura visceral em cães. Foram realizados exames de ultrassonografia da adrenal e as imagens editadas com auxílio de programa computacional e tomografia computadorizada helicoidal para quantificação da gordura visceral em oito cães adultos jovens hígidos, imediatamente antes e após 30 dias de terapia com prednisona em dose terapêutica (2mg/kg-1 de peso, a cada 24 horas, via oral). Verificou-se significativa (p<0,005) diminuição das dimensões da adrenal e significativo (p<0,001) aumento na quantidade de gordura visceral entre os diferentes momentos experimentais. Foi possível comprovar a aplicabilidade das técnicas de diagnóstico imagenológico utilizadas. / The glucocorticoids are widely used in clinical practice, but important adverse effects are described in dog. The aim of this study was to investigate the influence of prednisone on adrenal size and amount of visceral fat in dogs. Images of adrenal ultrasound examinations were edited with the aid of computer program and helical computed tomography as made for quantification of visceral fat in eight healthy young adult dogs immediately before and after 30 days of steroid with therapy prednisone in dose (2mg for each kg, each 24 hours, orally). There was adrenocortical atrophy and increased amount of intra-abdominal fat (p <0.005) between the different experimental time. It was possible to prove the applicability of diagnostic imaging techniques used.
199

A ultra-sonografia no diagnóstico do refluxo gastroesofágico em crianças

Sakuno, Telma January 2002 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Ciências Médicas. / Made available in DSpace on 2012-10-19T20:27:06Z (GMT). No. of bitstreams: 0Bitstream added on 2014-09-26T02:09:15Z : No. of bitstreams: 1 192089.pdf: 7625679 bytes, checksum: 5c30e0c73c94bc94a526b64dc5d207b0 (MD5) / Objetivo: Avaliar a ultra-sonografia como meio diagnóstico do RGE, comparando-a com a seriografia esôfago-gastro-duodenal (SEGD).
200

Aspectos ultrassonográficos da glândula tireoide hígida em equinos / Ultrasonographic features of the healthy throid gland in horses

Viana, Gustavo Fernandes [UNESP] 22 June 2015 (has links) (PDF)
Made available in DSpace on 2015-12-10T14:22:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-06-22. Added 1 bitstream(s) on 2015-12-10T14:28:32Z : No. of bitstreams: 1 000852786_20170727.pdf: 361665 bytes, checksum: d5d808335081a9c3fed7e2b8e799fbc5 (MD5) Bitstreams deleted on 2017-07-28T12:36:26Z: 000852786_20170727.pdf,. Added 1 bitstream(s) on 2017-07-28T12:37:12Z : No. of bitstreams: 1 000852786.pdf: 1033847 bytes, checksum: 6afb41561aed8a3d20a5bcb13d508b71 (MD5) Bitstreams deleted on 2017-08-07T14:09:17Z: 000852786.pdf,. Added 1 bitstream(s) on 2017-08-07T14:10:19Z : No. of bitstreams: 1 000852786.pdf: 1033847 bytes, checksum: 6afb41561aed8a3d20a5bcb13d508b71 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A aplicação da ultrassonografia (USG) pode fornecer dados valiosos para eficiente intervenção clínica e cirúrgica em casos de alterações tireoidianas. Entretanto, existem poucos estudos relacionados ao emprego da USG como método de avaliação da glândula tireoide (GT) em cavalos. Portanto, foi objetivo estabelecer parâmetros de análise da GT hígida em equinos adultos através do exame ultrassonográfico em modo B e Doppler. Onze equinos (vinte e dois lobos tireoidianos) foram selecionados através de resultados negativos para tireopatias no exame clínico, laboratorial (tiroxina livre por diálise de equilíbrio), ultrassonográfico e citológico. Foram determinadas as médias e os desvios padrão das dimensões dos lobos tireoidianos (LTs), e a velocidade do pico sistólico, índice de resistividade e pulsatilidade de suas respectivas artérias tireoideas craniais (ATCs). Os contornos, ecotextura, ecogenicidade e padrão do fluxo em cores do parênquima (PFCP) tireoidiano foram também avaliados. Não houve diferenças significativas entre as médias dos valores obtidos para os LTs esquerdo e direito. O mesmo ocorreu para ATC esquerda e direita. A USG se mostrou uma eficiente metodologia diagnóstica para definir os valores de referência da GT em equinos adultos. Apesar dos LTs esquerdo e direito poderem apresentar formato geral distinto num mesmo animal, outros parâmetros como as dimensões, contornos, características do parênquima e vascularização se mostraram semelhantes. A partir desses critérios, se um dos lobos for acometido por tireopatia, o lobo contra-lateral poderá servir de base para avaliação do outro alterado. Além disso, os parâmetros do Doppler espectral unilateral da ATC poderá ser utilizado para avaliar doenças tireoidianas difusas / The application of ultrasonography can provide valuable data for efficient clinical and surgical intervention in cases of thyroid disorders. However, there are few studies related to the use of the USG as an evaluation method of the thyroid gland (TG) in horses. The objective was to establish analysis parameters of healthy TG in adult horses by B and Doppler mode ultrasonography. Eleven horses (twenty-two thyroid lobes) were selected through negative for thyroid disorders on clinical examination, laboratory (free thyroxine by equilibrium dialysis), USG and cytology. It was determined the means and standard deviations of dimensions of the thyroid lobes (TLs), and peak systolic velocity, resistive and pulsatility index their respective cranial thyroid arteries (ACTs). The contours, echotexture, echogenicity and parenchymal color flow pattern (PCFP) thyroid were also evaluated. There were no significant differences between values obtained for the left and right TLs. The same happened to left and right ACTs. The USG proved an efficient diagnostic methodology for defining the TG reference values in adult horses. Although the left and right TLs may present distinct general format in the same animal, other parameters as the dimensions, contours, parenchymal and vascular characteristics were similar. From these criteria, if one of the lobes is affected by thyroid disorders, the contralateral lobe could form the basis for evaluation of another lobe changed. In addition, the study unilateral ACT spectral Doppler parameters may be used to evaluate diffuse thyroid disorder

Page generated in 0.0802 seconds