• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 32
  • 8
  • Tagged with
  • 40
  • 15
  • 12
  • 6
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Lufttemperaturens, vindens och snödjupets inverkan på utveckling av laviner i Abisko/Riksgränsen under 2021

Dahlström, Maria January 2023 (has links)
Det huvudsakliga syftet med denna studie är att studera möjligheten att koppla rapporterade väderdata till antalet rapporterade laviner inom samma område och undersöka i vilken utsträckning rapporterad temperatur, snödjup och vindhastighet påverkar utvecklingen av laviner. I arbetet studeras väderdata kopplat till lavinrapportering inom området Abisko/Riksgränsen. Studien fokuserar på spontant utlösta laviner, det vill säga laviner som utlösts av naturliga väderfenomen utan mänsklig påverkan.Studien bygger på väderdata från endast en väderstation, Katterjåkk, som således får representera hela lavinprognosområdet Abisko/Riksgränsen. Trots att vädret kan uppvisa lokala variationer inom det valda området, tyder resultaten på att det finns ett klart samband mellan å ena sidan väderförhållandena (förändringar i snödjup, vindstyrka och temperatur) och antalet spontant utlösta laviner.Studien visar att väderdata kan användas för att undersöka lavinutveckling i området, och att mer eller mindre ökande snödjup i kombination med vindhastighet verkar vara den huvudsakliga orsaken bakom lavinerna. Många laviner under senare vår verkar också kunna initieras av snabba temperaturförändringar.
12

Vindstabilisering av SIPS byggnader i Sverige / Wind Stabilization of SIPS buildings in Sweden

Hasani, Esmael, Maniea, Johan January 2023 (has links)
Detta arbete handlar om vindstabilisering av en SIPS byggnad i Sverige där fokuset ligger påhur infästningar sker mellan grundplattan och väggarna. SIPS (Structural insulated panels) ärett bärande isoleringselement som används för att bygga hela byggnadskalet. Det är ennykommen byggnadsteknik i Sverige som används för passivhus för att kunna minskaenergianvändningen enligt Parisavtalet. Elementen är prefabricerade och binds ihop medglasfiberbalkar, som även används för att förstärka öppningar i byggnaden (dörrar ochfönster). Metoden som kommer att användas i detta arbete är finita elementmetoden medhjälp av datorprogrammet FEM-design av företaget Strusoft. I programmet återuppbyggdesmodellen som analyserade byggnaden enligt finita elementmetoden och beräknade medhänsyn till Eurokod. I samarbete med SIPs företaget Avis Building technology modelleradesbyggnaden och skarven enligt en modul från företaget, där resultatet sedan analyserades.Detta resulterade skarven består av skruvar som fästs i en Z-profil som binder ihop väggenmed grunden. Resultatet gav de skjuv-och normalkrafter som skruven och plåten utsätts för.Dessa krafter analyserades och på så sätt kunde en lämplig leverantör hittas som tillverkarskruvar som kan ta upp dessa laster. Valet landade på Zebra Pias (hexagonal head withcollar) av företaget WÜRTH. Denna metod användes även för att hitta en leverantör somtillverkar passande profiler som kan hantera lasterna utan att gå i brott. Valet landade påaluminiumprofiler med tjockleken 4 mm av företaget Tibnor. På så sätt har frågeställningenom hur en infästning av SIPs-byggnad kan ske blivit besvarad. Resultaten i FEM-designvisar att en SIPS-byggnad kan vindsatbiliseras i Sverige med undantag vissa delar som kankompletteras med en bärande innervägg för att nå full stabilisering. Men denna frågeställningkan inte besvaras med full säkerhet utan att mer data och forskning om elementet görs. Alltför många parametrar om elementens egenskaper var okända vilket ledde till en osäkerhet. Iprogrammet var byggnaden stabiliserad men hade för stora deformationer på vissa ställen.Detta betyder inte att en sådan byggnad inte kan stabiliseras, utan fler undersökningar måstegöras innan slutsatsen kan dras. I arbetet gjordes inga prövningar av elementet vilket bidrogtill denna osäkerhet. Vid fler mätningar och prövningar kan en SIPS-byggnad absolut bli enframtida byggnadsteknik i Sverige.
13

Företagsvärdering med Fundamental analys : Är Eolus aktie över- eller undervärderad? / Business valuation with Fundamental analysis : Is Eolus share over- or undervalued?

Stupic, Slavisa, Järvinen, Sebastian January 2010 (has links)
<p><strong>Datum</strong>: 2010-06-03</p><p><strong>Kurs</strong>: Kandidatuppsats i Företagsekonomi</p><p><strong>Lärosäte</strong>: Mälardalens högskola, Västerås</p><p><strong>Institution</strong>: Akademin för hållbar samhälls- och teknikutveckling</p><p><strong>Titel</strong>: Företagsvärdering med Fundamental analys</p><p><strong>Författare</strong>: Sebastian Järvinen och Slavisa Stupic</p><p><strong>Handledare</strong>: Riitta Lehtisalo</p><p><strong>Examinator</strong>: Cecilia Lindh</p><p><strong>Frågeställningar</strong>: Vilka värderingsmetoder och modeller är mest lämpliga för en värdering av Eolus Vind AB?</p><p>Är Eolus aktie över- eller undervärderad?</p><p>Vilken påverkan har avvikelser gentemot prognos i värderingen av Eolus?</p><p><strong>Syfte</strong>: Syftet med studien är att utföra en företagsvärdering av Eolus för att fastställa om dess aktie är över- eller undervärderad samt behandla osäkerheten kring en värdering.</p><p><strong>Metod</strong>: I studien har en deduktiv metod tillämpats då vi valt att utgå från redan befintlig teori. Vidare har kvalitativa och kvantitativa metoder tillämpats för att få en djupare förståelse för hur värderingsmetoderna och modellerna används i praktiken som sedan ligger till grund för värderingen av Eolus.</p><p><strong>Slutsats</strong>: Lämpligaste metoden för en värdering av Eolus är en så kallad DCF analys, där en fundamental analys ligger till grund för de prognostiserade antaganden. Det innebär att bolaget, marknaden och dess bransch studeras för att sedan ligga till grund för de prognoser och antaganden som krävs i en DCF analys. En multipelvärdering är att föredra då den anses göra DCF analysen komplett. Enligt våra prognoser, antaganden och beräkningar anser vi Eolus aktie vara undervärderad gentemot dagens kurs.</p><p><strong>Nyckeltal</strong>: Företagsvärdering, Fundamental analys, Eolus Vind AB, DCF, CAPM, WACC, multipelvärdering</p> / <p><strong>Date</strong>: 2010-06-03</p><p><strong>Subject</strong>: Bachelor Thesis in Business Administration</p><p><strong>University</strong>: Mälardalen University, Vasteras</p><p><strong>Institute</strong>: School of Sustainable Development of Society and Technology</p><p><strong>Title</strong>: Business valuation with Fundamental analysis</p><p><strong>Authors</strong>: Sebastian Järvinen and Slavisa Stupic</p><p><strong>Tutor</strong>: Riitta Lehtisalo</p><p><strong>Examiner</strong>: Cecilia Lindh</p><p><strong>Questions</strong>: What valuation methods and models are most appropriate for the valuation of Eolus Vind AB?</p><p>Is Eolus share over- or undervalued?</p><p>What influence do the deviations in the prognosis have against the forecasted valuation of Eolus?</p><p><strong>Purpose</strong>: The purpose of this study is to perform a Business valuation of Eolus and determine it its share is over- or undervalued. The study will also deal with the uncertainty in the valuation.</p><p><strong>Method</strong>: The study has a deductive approach, which says that the starting point lies in a existing theory. Furthermore, qualitative and quantitative methods are used to obtain a deeper understanding of how valuation methods and models are used in the practice, which t hen forms the basis of a valuation of Eolus.</p><p><strong>Conclusion</strong>: The most appropriate method for a valuation of Eolus is a DCF analysis, where the first step is to do a fundamental analysis, which involves a study of the company, its industry and the market to form a basis for the forecasts, and assumptions that are required in a DCF analysis. A relative valuation is a preferable combination with the DCF analysis. According to our projections, assumptions and estimates we believe that Eolus share is undervalued in relation to today’s share price.</p><p><strong>Keywords</strong>: Business Valuation, Fundamental analysis, Eolus Vind AB, DCF, CAPM, WACC, relative valuation</p>
14

Företagsvärdering med Fundamental analys : Är Eolus aktie över- eller undervärderad? / Business valuation with Fundamental analysis : Is Eolus share over- or undervalued?

Stupic, Slavisa, Järvinen, Sebastian January 2010 (has links)
Datum: 2010-06-03 Kurs: Kandidatuppsats i Företagsekonomi Lärosäte: Mälardalens högskola, Västerås Institution: Akademin för hållbar samhälls- och teknikutveckling Titel: Företagsvärdering med Fundamental analys Författare: Sebastian Järvinen och Slavisa Stupic Handledare: Riitta Lehtisalo Examinator: Cecilia Lindh Frågeställningar: Vilka värderingsmetoder och modeller är mest lämpliga för en värdering av Eolus Vind AB? Är Eolus aktie över- eller undervärderad? Vilken påverkan har avvikelser gentemot prognos i värderingen av Eolus? Syfte: Syftet med studien är att utföra en företagsvärdering av Eolus för att fastställa om dess aktie är över- eller undervärderad samt behandla osäkerheten kring en värdering. Metod: I studien har en deduktiv metod tillämpats då vi valt att utgå från redan befintlig teori. Vidare har kvalitativa och kvantitativa metoder tillämpats för att få en djupare förståelse för hur värderingsmetoderna och modellerna används i praktiken som sedan ligger till grund för värderingen av Eolus. Slutsats: Lämpligaste metoden för en värdering av Eolus är en så kallad DCF analys, där en fundamental analys ligger till grund för de prognostiserade antaganden. Det innebär att bolaget, marknaden och dess bransch studeras för att sedan ligga till grund för de prognoser och antaganden som krävs i en DCF analys. En multipelvärdering är att föredra då den anses göra DCF analysen komplett. Enligt våra prognoser, antaganden och beräkningar anser vi Eolus aktie vara undervärderad gentemot dagens kurs. Nyckeltal: Företagsvärdering, Fundamental analys, Eolus Vind AB, DCF, CAPM, WACC, multipelvärdering / Date: 2010-06-03 Subject: Bachelor Thesis in Business Administration University: Mälardalen University, Vasteras Institute: School of Sustainable Development of Society and Technology Title: Business valuation with Fundamental analysis Authors: Sebastian Järvinen and Slavisa Stupic Tutor: Riitta Lehtisalo Examiner: Cecilia Lindh Questions: What valuation methods and models are most appropriate for the valuation of Eolus Vind AB? Is Eolus share over- or undervalued? What influence do the deviations in the prognosis have against the forecasted valuation of Eolus? Purpose: The purpose of this study is to perform a Business valuation of Eolus and determine it its share is over- or undervalued. The study will also deal with the uncertainty in the valuation. Method: The study has a deductive approach, which says that the starting point lies in a existing theory. Furthermore, qualitative and quantitative methods are used to obtain a deeper understanding of how valuation methods and models are used in the practice, which t hen forms the basis of a valuation of Eolus. Conclusion: The most appropriate method for a valuation of Eolus is a DCF analysis, where the first step is to do a fundamental analysis, which involves a study of the company, its industry and the market to form a basis for the forecasts, and assumptions that are required in a DCF analysis. A relative valuation is a preferable combination with the DCF analysis. According to our projections, assumptions and estimates we believe that Eolus share is undervalued in relation to today’s share price. Keywords: Business Valuation, Fundamental analysis, Eolus Vind AB, DCF, CAPM, WACC, relative valuation
15

IT-system: Försvarsanställdas främsta frustration : Vad kan göras för att öka användarnas uppskattning av IT-systemen? / IT systems: The number one reason for frustration among service members in the Swedish Armed Forces : What can raise the appreciation of the IT systems among the users?

Gillsparr, Torbjörn January 2018 (has links)
Studien tar sin utgångspunkt i att Försvarsmaktens personal återkommande har angett en låg uppskattning till myndighetens IT-system i den årliga medarbetarundersökningen FM VIND. Detta arbete har undersökt bakomliggande orsaker till resultatet genom att studera förhållanden vid de tre taktiska staberna; ATS, MTS och FTS. Med ett antal bakomliggande faktorer identifierade, och med stöd av teoretiska modeller, ges förslag på åtgärder som kan bistå till att IT-systemen får en högre uppskattning hos användarna. Studien redovisar bland annat att FM AP är det mest uppskattade IT-systemet, och att SWECCIS är det minst uppskattade IT-systemet i urvalsgruppen. / The study is based on the fact that the service members of the Swedish Armed Forces have repeatedly stated a low estimate of the IT systems in the annual employee survey FM VIND.  This work has investigated underlying causes of the outcome, by studying the conditions of the three Component Commands; LCC, MCC and ACC. With a number of underlying factors identified, and with the support from theoretical models, suggestions are made for measures that can help the IT systems gain a higher appreciation among users. The study reports, among other things, that FM AP is the most appreciated IT system, and that SWECCIS is the least valued IT system in the selection group.
16

Wind driven snow accumulation variability and terrain : Establishing a relationship by using GPR on Svalbard. / Den vinddrivna snöackumuleringens variabilitet och terräng : Fastställande av sambandet med hjälp av markpenetrerande radar på Svalbard

Heerema, Catharina January 2016 (has links)
Snow accumulation patterns can be highly variable depending on terrain and wind. Knowledge of spatial variability of snow accumulation is of high relevance for mass balance modelling. By not incorporating the variability in snow cover, the estimation in mass fluxes and the surface melt are incorrectly presented, affecting the eventual estimation of for instance contribution to sea level rise. Additionally, knowledge of snow accumulation variability is essential for assessing the reliability of point-wise mass balance measurements. Using ground penetrating radar (GPR), the spatial variability of snow can be mapped with both a great spatial and temporal resolution. GPR enables tracing of summer surface melt layers, resulting in a 2D reconstruction of past snow accumulation and associated variability. GPR measurements have been done on Svalbard, during 2012, 2013 and 2014. Based on the selected 2009 summer surface in the GPR measurements, accumulation rates were estimated between 2009-2012; 2009-2013 and 2009-2014. In addition, several terrain parameters are computed by combining DEM calculations with wind direction, resulting in a sheltering index, slope and curvature. We explore relationships between the found accumulation pattern and the terrain parameters with varying wind directions. Correlations between terrain and accumulation depend on the selected wind angle, which appears to change with elevation. The results suggest that localized wind patterns prevail on the glacier and shape the snow cover. Katabatic winds form at low elevations on the glacier and are oriented in the glacier direction of approximately 20 degrees. At intermediate elevation, winds from the east-southeast regulate the accumulation pattern. On the upper parts of the glacier, the terrain is more exposed and winds from large-scale atmospheric circulation, at 240 degrees, become more important in formation of the snow accumulation pattern. Correlations are overall high, indicating a strong influence of terrain features on the accumulation distribution. No distinction can be made between the different terrain parameters and accumulation, all returning similar correlations with accumulation except for curvature, which overall returns slightly lower correlations. In addition, the results found great spatial variability in snow accumulation, underlining the importance of incorporating snow accumulation variability in glacier mass balance models. / Snow accumulation patterns can be highly variable depending on terrain and wind. Knowledge of spatialvariability of snow accumulation is of high relevance for mass balance modelling. By not incorporating the variability in snow cover, the estimation in mass fluxes and the surface melt are incorrectlypresented, affecting the eventual estimation of for instance contribution to sea level rise. Additionally,knowledge of snow accumulation variability is essential for assessing the reliability of point-wise mass balance measurements.Using ground penetrating radar (GPR), the spatial variability of snow can be mapped with both agreat spatial and temporal resolution. GPR enables tracing of summer surface melt layers, resulting in a 2D reconstruction of past snow accumulation and associated variability. GPR measurements have been done on Svalbard, during 2012, 2013 and 2014. Based on the selected 2009 summer surface in the GPR measurements, accumulation rates were estimated between 2009-2012; 2009-2013 and 2009-2014. In addition, several terrain parameters are computed by combining DEM calculations with wind direction, resulting in a sheltering index, slope and curvature. We explore relationships between the found accumulation pattern and the terrain parameters with varying wind directions.Correlations between terrain and accumulation depend on the selected wind angle, which appears to change with elevation. The results suggest that localized wind patterns prevail on the glacier and shape the snow cover. Katabatic winds form at low elevations on the glacier and are oriented in the glacier direction of approximately 20 degrees. At intermediate elevation, winds from the east-southeast regulate the accumulation pattern. On the upper parts of the glacier, the terrain is more exposed and winds from large-scale atmospheric circulation, at 240 degrees, become more important in formation of the snow accumulation pattern. Correlations are overall high, indicating a strong influence of terrain features on the accumulation distribution. No distinction can be made between the different terrain parameters and accumulation, all returning similar correlations with accumulation except for curvature, which overall returns slightly lower correlations. In addition, the results found great spatial variability in snowaccumulation, underlinin
17

Tätning eller ventilering mot fukt på kalla vindsutrymmen

Holmgren, Johan, Brar, Harry, Hjalmarsson, Åke January 2006 (has links)
This study was done regarding whether sealing or ventilation is the best solution to prevent moisture on cold attics. The authors of this report addressed the problem with moisture in attics when they started their cooperation with Peab. The methods included interviews with people, database research, and calculations of a project in Akersberga north of Stockholm. The conclusion is based on interviews and other information as they are analyzed in relation to the house of reference. The focus of this report is on problems with moisture in the attics known as cold attics. The background of the problem with moisture is that today’s slabs are usually insulated to save energy and that the attics nearly gives the climate as the outdoor climate. The contribution of moisture increases this problem when the relative humidity reaches 75 %, which in most cases promotes mould. Moisture comes with natural ventilation through the eaves due to outside humidity and precipitation finding its way in, and at the same time comes from the inside through openings or cracks on concrete slabs, ventilation ducts, and attic doors. Moisture also comes into the attic from building materials, especially from the concrete slabs that evaporate which gives off a lot of moisture throughout the years. These things are possible to prevent with four different methods ventilation, sealing, heating or insulating the outer roof. Moisture effects are calculated from the examples given by Roxull FuktFakta in comparison with the authors own calculations from other databases. The object of reference, Bergahojden 6, is a residential building that has served as a model for all the calculations. The conclusion shows that air circulation has to increase to get out the moisture through the ventilation. The winters here in Sweden are so humid that the ventilation should be suitable enough so that the humidity does not rise above 75 % in the attic. To heat up the attic with devices, or by using roof insulation, would bring the same climate as the outdated slab insulations. There will be a big loss of energy with heat going out if the roof is not insulated. To apply both systems would be a double investment which would be hard to convince builders of. The conclusion is that the best method would be to combine sealing with ventilation, or a possible mechanical system which allows the attic to be ventilated during the summer and sealed during the winter.
18

Tätning eller ventilering mot fukt på kalla vindsutrymmen

Holmgren, Johan, Brar, Harry, Hjalmarsson, Åke January 2006 (has links)
<p>This study was done regarding whether sealing or ventilation is the best solution to prevent moisture on cold attics. The authors of this report addressed the problem with moisture in attics when they started their cooperation with Peab.</p><p>The methods included interviews with people, database research, and calculations of a project in Akersberga north of Stockholm. The conclusion is based on interviews and other information as they are analyzed in relation to the house of reference. The focus of this report is on problems with moisture in the attics known as cold attics.</p><p>The background of the problem with moisture is that today’s slabs are usually insulated to save energy and that the attics nearly gives the climate as the outdoor climate. The contribution of moisture increases this problem when the relative humidity reaches 75 %, which in most cases promotes mould. Moisture comes with natural ventilation through the eaves due to outside humidity and precipitation finding its way in, and at the same time comes from the inside through openings or cracks on concrete slabs, ventilation ducts, and attic doors. </p><p>Moisture also comes into the attic from building materials, especially from the concrete slabs that evaporate which gives off a lot of moisture throughout the years. These things are possible to prevent with four different methods ventilation, sealing, heating or insulating the outer roof. </p><p>Moisture effects are calculated from the examples given by Roxull FuktFakta in comparison with the authors own calculations from other databases. The object of reference, Bergahojden 6, is a residential building that has served as a model for all the calculations. The conclusion shows that air circulation has to increase to get out the moisture through the ventilation. The winters here in Sweden are so humid that the ventilation should be suitable enough so that the humidity does not rise above 75 % in the attic. </p><p>To heat up the attic with devices, or by using roof insulation, would bring the same climate as the outdated slab insulations. There will be a big loss of energy with heat going out if the roof is not insulated. To apply both systems would be a double investment which would be hard to convince builders of. </p><p>The conclusion is that the best method would be to combine sealing with ventilation, or a possible mechanical system which allows the attic to be ventilated during the summer and sealed during the winter.</p>
19

Effekter vid tilläggsisolering av kallvindar ur fuktsynpunkt / Moisture effects of additional insulation in cold attics

Schill, Elin, Flodins, Tina January 2015 (has links)
Ekonomiska aspekter och krav på minskad energianvändning leder bland annat till tilläggsisolering av vindsbjälklag och byte av uppvärmningssystem. Åtgärderna ger ett kallare och fuktigare klimat på vinden vilket gynnar mögeltillväxt. Minst 60 % av alla traditionella vindar med självdrag kan anses ha riklig tillväxt av mögelsvamp (Ahrenens och Borglund 2007). Syftet med denna studie är att ta ett steg i rätt riktning om vilka åtgärder som kan göras på de vindar som idag är angripna. I denna studie har tre vindars fukttillstånd utretts och jämförts. Ett av objekten har simulerats och utsatts för olika åtgärder. Simuleringarna bekräftar att minskad isolering ger ett torrare klimat på vinden. En ökning av ventilationen ger liten men knappt märkbar förbättring av vindsklimatet. Hög värmekapacitivitet hos isoleringsmaterial verkar ge en jämnare temperatur på vinden vilket sänker luftfuktigheten. Genom att isolera vindens tak och gavlar sker en markant sänkning av mögelrisken. Då varje vind är olika uppbyggd finns ingen generell lösning utan varje vind måste bedömas utifrån sina nuvarande förhållanden.
20

Procedurellt genererade träd som påverkas av vind i realtid

Nordquist, Oskar January 2008 (has links)
<p>Denna rapport behandlar procedurell generering av träd och skapandet av en applikation som med hjälp av multitrådade tekniker genererar och renderar dessa i realtid. Detta exemplifieras av att träden påverkas av vindkrafter. Algoritmen för trädgenerering beskrivs utförligt samt redogör för olika tekniker för att uppnå realtidsprestanda när träden påverkas av vindkrafter.</p>

Page generated in 0.0694 seconds