41 |
Avaliação das fendas marginais em restaurações de resina composta com variação de alguns determinanates clínicos / Evaluation of marginal gaps in composite resin restorations with some variation of clinical determinantsMarco Antonio Gallito 28 April 2008 (has links)
O objetivo deste estudo foi comparar, por meio de mensuração das fendas na interface dentina - restauração de resina composta com utilização de algumas variáveis: fotoativação com lâmpada halógena e com LED; utilização de resina microhíbrida com partículas nanométricas Filtek Z350 ou sem estas partículas Filtek Z250; variação do sistema adesivo (Adper Single Bond 2 ou Adper Scotchbond Multi Purpose); variação da temperatura da resina composta; uso de dessensibilizante dentinário ou não; remoção do colágeno da dentina ou não e variação da intensidade de luz na fotoativação. Foram utilizados 70 molares humanos recém-extraídos, com cavidades circulares na dentina superficial de cada face proximal, foram divididos em 10 amostras para cada variável citada acima. Os dentes foram devidamente restaurados, seguindo as instruções dos fabricantes, para todos os grupos e mantidos em estufa bacteriológica por um período de 7 dias, após este período, foram polidos e as réplicas de resina epoxídica foram confeccionadas a partir de uma moldagem com silicone por adição, as mesmas foram levadas ao MEV, para a análise. As fendas foram mensuradas com o auxílio do software UTHSCSA Image tool e os dados foram submetidos à análise estatística pelo teste t de Student para a obtenção dos resultados. Com base nos resultados obtidos pode-se concluir que: os menores valores de fendas marginais foram obtidos quando da utilização de luz halógena (t=3,246 e p= 0,02) e com variação da intensidade desta luz (t= - 8,808 e p= 0,00). Os menores valores relativos de fendas, mas sem diferença estatística significante, foram encontrados, também, quando a resina Filtek Z350 foi comparada com a resina Filtek Z250 (t=-0,426 e p= 0,672) e quando o adesivo Adper Scotchbond Multi Purpose foi comparado com o Sistema Adper Single Bond 2 (t= 0,883 e p= 0,382). Os maiores valores de fendas marginais foram obtidos com a resina Filtek Z350 préaquecida a 60oC (t= -3,961 e p=0,000); com o uso de dessensibilizante dentinário (t=-3,062 e p=0,004) e com a remoção do colágeno pelo hipoclorito de sódio (t= -8,808 e p= 0,000). / The objective of this study was to compare through the cracks measurements in the dentin resin interface, using some variables: light activation with halogenic lamp and with LED; the use of micro-hybrid resin with or without nanofiller (Filtek Z350 anda Filtek Z250); variation of the adhesive systems (Adper Single Bond 2 or Scotchbond Multi Purpose); variation of the temperature in the compound resin; to use or not use the dentin desensitizing; to remove or not the dentin collagen and the light intensity variation in the light-curing. It was used 70 human extracted molars, with circular cavities in the superficial dentin of each proximal face; they were divided in 10 samples to each supra cited variable. The teeth were restored, followint the manufacturer instructions, and they were kept in a bacteriologtical kiln during a seven days period. After this time, the teeth were glossed, the resin replica were made from an addition silicone casting and these were took to the MEV, to be analyzed. The cracks were measured with the help of a UTHSCSA tool image software and the data were submited to an statistical analysis with the Student t test. The results obtained give the following conclusions: the lower values of marginal cracks were obtained when it was used the halogenic light (t = 3,246 and p = 0,02) and due the intensity variation of this light (t = 8,808 and p = 0,00). The lowest values related to the cracks were found when the Filtek Z350 resin was compared to the Filtek Z250 resin (t = 0,426 and p = 0,672), and when the Adper Scotchbond Multipurpose adhesive was compared with the Adper Single Bond 2 system (t = 0,883 and p = 0,382). The greatest values of marginal cracks were obtained with Filtek Z350 resin preheated at 60 degrees (t = -3,961 and p = 0,00); with the use of dentin desensitizing (t = -3,062 and p = 0,004) and with the removal of the collagen by using sodium hypochlorite (t = -8,808 and p = 0,000).
|
42 |
Estudo do caráter dirradicalar de compostos da classe 1,3-Oxazol e 1,3-Tiazol.Dantas, Lucinêz da Cruz 27 May 2013 (has links)
Made available in DSpace on 2015-05-14T13:21:22Z (GMT). No. of bitstreams: 1
ArquivoTotalLucinez.pdf: 2070839 bytes, checksum: 3d56c7860a648e855f328fcab8ae6afb (MD5)
Previous issue date: 2013-05-27 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The mesoionic compounds can not be represented by a purely ionic or
covalent structure. Are neutral compounds that have well-separated regions of
positive and negative charges, leading to a high dipole moment. They show
wide range of applications, through biology and medicinal chemistry, as well in
the obtaining products of technological interest. In this study, the stability and
diradicalar character of four mesoionic rings were investigated: 1,3-oxazol-5-
one, 1,3-oxazol-5-thione, 1,3-thiazol-5-one and 1,3-thiazol-5-thione. Many
criteria to quantify the diradicalar character were used: (I) HOMO-LUMO
energy difference (EHL, inversely proportional to the diradicalar character;
EHL = 0 corresponding to a pure diradical), (ii) determination of the energy
difference due to the broken symmetry in the unrestricted formalism (ESS),
(iii) determination of the energy difference between the singlet and triplet
wave functions (EST); and (iv) diradicalar character (Y0, calculated from the
occupation numbers n of HOMO and LUMO natural orbitals, in the unrestricted
formalism). Various methods of electronic structure (DFT/B3LYP, MP2, CCSD
and QCISD) with different basis sets (6-311+ G* and aug-cc-pVDZ) were
employed. It was observed that: (i) a suitable choice of the substituent at R
position (the outer ring) is important for the structural stability;
(ii) substitution of oxygen by sulfur in the R and R positions (into the ring) do
a little contribution for the diradicalar character (Y0 < 1% in all cases,
indicating pronounced mesoionic character in the investigated structures); and
(iii) the use of an electron donating group at R position and an electron
withdrawing group at R position contribute to maximize the mesoionic
character. Thus, it was possible to describe the dependencies of the molecular
structure on the electronic properties, and the effect of substitutions, which is
of great importance for the control of mesoionic character. / Os compostos mesoiônicos não podem ser representados por uma
estrutura totalmente covalente ou puramente iônica. São compostos neutros
que possuem regiões bem separadas de cargas positiva e negativa,
conferindo-lhes elevado momento de dipolo. Apresentam faixa ampla de
aplicações, passando pela biologia e a química medicinal, bem como na
obtenção de produtos de interesse tecnológico. Neste trabalho, investigou-se o
caráter dirradicalar de quatro anéis mesoiônicos: 1,3-oxazol-5-ona, 1,3-
oxazol-5-tiona, 1,3-tiazol-5-ona e 1,3-tiazol-5-tiona, procurando a melhor
representação eletrônica, e como a reatividade influencia no tipo de reação em
que participam. Foram utilizados diferentes critérios para a quantificação do
caráter dirradicalar: (i) diferença de energia HOMO-LUMO (EHL, inversamente
proporcional ao caráter dirradicalar; EHL = 0 correspondendo a um dirradical
puro); (ii) determinação da diferença de energia devida à quebra de simetria
no formalismo irrestrito (ESS); (iii) determinação da diferença de energia entre
as funções de onda singleto e tripleto (EST); e (iv) caráter dirradicalar (Y0,
calculado a partir dos números de ocupação n dos orbitais naturais HOMO e
LUMO, determinados no formalismo irrestrito). Foram empregados diversos
métodos de estrutura eletrônica (DFT/B3LYP, MP2, CCSD e QCISD) com
diferentes conjuntos de bases (6-311+G* e aug-cc-pVDZ). Observou-se que:
(i) a escolha adequada do substituinte na posição R (externa ao anel) é
importante para a estabilidade estrutural; (ii) a substituição do oxigênio por
enxofre nas posições R e R (no anel) pouco contribui para o caráter
dirradicalar (Y0 < 1% em todos os casos, indicando caráter mesoiônico
pronunciado nas estruturas investigadas); e (iii) a utilização de um grupo
doador de elétrons na posição R e retirador na R contribui para maximizar o
caráter mesoiônico. Dessa forma, foi possível descrever as dependências da
estrutura molecular sobre as propriedades eletrônicas, e o efeito das
substituições, que é relevante para o controle do caráter mesoiônico.
|
43 |
Análise conformacional e aplicações sintéticas de algumas N-metóxi-N-metil-2-feniltiopropanamidas 4\'-substituídas e suas formas mono- e di-oxigenadas / Conformational Analysis and synthetical applications of some N- methoxy- N-methyl-2-[(4\'-substituted)-phenylthio]-propanamides and their mono- e di- oxigenated formsNelson Luis de Campos Domingues 26 June 2007 (has links)
A presente tese relata a síntese e a análise conformacional das: N-metóxi-N-metil- 2-feniltiopropanamidas 4\'-substituídas (I), N-metóxi-N-metil-2- fenilssulfinilpropanamidas 4\'-substituídas (II) e N-metóxi-N-metil-2- fenilssulfonilpropanamidas 4\'-substituídas (III), através da espectroscopia no Infravermelho na região da banda da carbonila (vco), apoiada por cálculos teóricos. A análise conformacional de (I) indicou, através de dados de DFT/cc-pVDZ a existência de um equilíbrio entre duas conformações gauche devido à ocorrência de uma forte interação orbitalar estabilizante π*co/σc-s nas mesmas. A série dos derivados sulfinilados (II) apresentou-se como um par de diastereoisômeros. A análise conformacional para o diast1 (par enantiomérico CRSS/CSSR), através do cálculo HF/6-31G** e IV, indicou a existência de um equilíbrio conformacional entre dois confôrmeros quasi-cis (q-c1 e q-c2) e outro gauche (g), sendo os confôrmeros quasi-cis (q-c1 e q-c2) mais estáveis devido à interação de transferência de carga Oσ-(CO)→Sσ+SO mais intensa do que a interação Oσ-(SO)→Cσ+CO presente no confôrmero gauche (g). A análise para o diast2 utilizando-se o cálculo HF/6-31G** indicou a presença dos confôrmeros quasi-gauche (q-g), e quasi-cis (q-c3) sendo o primeiro mais estável no estado gasoso por apresentar uma interação transferência de carga cruzada Oσ-(CO)→Sσ+SO e Oσ-(SO)→Cσ+CO. Os dados de cálculo HF/6-31G** para os derivados sulfonilados (III) indicaram um equilíbrio conformacional entre duas conformações gauche (g1 e g2) decorrente de uma interação Coulômbica e de transferência de carga cruzada Oδ-(SO2)→Cδ+CO e Oδ-(CO)→Sδ+SO2. A presente Tese também relata a obtenção de compostos ß-lactâmicos acilados no carbono C3 e C4. As N-metóxi-N-metil-2-feniltiopropanamidas-4\'-substituídas (I) agem como acilantes do anel ß-lactâmico (N-fenil-2-azetidinona) para obtenção dos derivados ß-lactâmico C3 acilados. A reação foi realizada com sucesso, contudo, a purificação dos compostos alvo não se mostrou eficaz obtendo-se apenas as 3-[2- (4\'-feniltio)propanoil]-N-fenil- e 3-[2-(4\'- clorofeniltio)propanoil]-N-fenil-2-azetidinonas através de um processo de cristalização. Para a obtenção dos derivados ß-lactâmicos C4 acilados utilizou-se a N-metóxi-N-metil-4-oxo-1-fenilazetidina-2- carboxamida como acilante dos carbânions derivados de 4\'-fenilmetilssulfóxidos [4\'-YPhS(O)CH3 Y= OMe, Me, H]. Esta reação forneceu as 1-fenil- (4-fenilssulfinilacetil- 3 4\'-substituídos)-2-azetidinonas correspondentes com bons rendimentos. A redução destas azetidinonas-sulfóxidos forneceu as azetidinonas-sulfetos correspondentes também com bons rendimentos / This thesis reports the synthesis and the conformational analysis of: N-methoxy-N- methyl-2-[(4\'-substituted)-phenylthio]-propanamides (I), N-methoxy-N-methyl-2-[(4\'- substituted)-phenylsulfinyl]-propanamides (II) and N-methoxy- N-methyl-2-[(4\'- substituted)-phenylsulfonyl]-propanamides (III) by Infrared spectroscopy through the analysis of the carbonyl stretching band supported by theoretical calculations. The conformational analysis of (I) through DFT computations have indicated the equilibrium of two gauche conformations due to a strong stabilizing π*co/σc-s orbital interaction. The group of sulfinyl derivatives (II) exist as a diastereomeric pair. The conformational analysis of diast1 (enantiomeric pair CRSS/CSSR) through IR and HF/6-31G** has shown the existence of an equilibrium between two quasi-cis (q-c1 and q-c2) and one gauche (g) conformers, being the quasi-cis conformers the more stable ones due to the Oσ-(CO)→Sσ+SO charge transfer interaction which in turn is stronger than the Oσ-(SO)→Cσ+CO orbital interaction which takes place in the gauche (g) conformer. As for diast2 the HF/6-31G** computations along IR data has indicated 2 the occurrence of the quasi-gauche (q-g) and quasi-cis (q-c ) conformers, being the former the more stable one in gaseous phase due to the Oσ-(CO)→Sσ+SO e Oσ-(SO)→Sσ+CO crossed charge transfer. The HF/6-31G** and vco data for the sulfonylated derivatives (III) have shown the existence of the equilibrium between two gauche (g1 and g2) conformations which are stabilized through Oδ-(SO2)→Cδ+CO and Oδ-(CO)→Sδ+SO2 electrostatic and charge transfer interactions. This Thesis also deals with the preparation of some C3 and C4 acylated ß-lactamic compounds. The N-methoxy- N-methyl-2-[(4\'-substituted)-phenylthio-propanamides (I) act as acylating agents of the ß-lactamic ring (N-phenyl-2-azetidinone) in order to obtain the C-3 acylated ß-lactamic derivatives. These reactions gave the target products contaminated with starting material in good yields except for the 3-[2- (4\'phenylthio)propanoyl]-N-phenyl- and 3-[2-(4\'-chlorophenylthio)propanoyl]-N- phenyl-2-azetidinones which were obtained in pure form after crystallization. As for the C-3 acylated ß-lactamic derivatives they were obtained from the reaction of N-methoxy-N-methyl-4-oxo-1-phenylazetidine-2-carboxamide and the appropriate carbanions of 4\'-substituted phenylmethylsulfoxides. This reaction gave the corresponding 1-phenyl- (4-substituted-phenylsulfinylacetyl)-2-azetidinones in good yields. The corresponding azetidinone-sulfides were obtained from the reduction of the azetidinone-sulfoxides.
|
44 |
Adoção de processos virtuais às estratégias organizacionais: estudos de casos no setor químico. / Adoption of virtual processes to the organizacional strategies: studies of cases in the chemical sector.Sibylle Sophie Hacker 19 December 2003 (has links)
Este trabalho tem como objetivo estudar como os processos virtuais estão sendo integrados nas estratégias organizacionais das empresas químicas. O processo virtual engloba todas atividades organizacionais, desde marketing, vendas, distribuição, serviços ao cliente e suporte pós venda. Utilizou-se dois modelos teóricos para avaliação dos aspectos organizacionais. Resultados da pesquisa mostraram que não houve uma definição clara para o uso de processos virtuais e sua adoção não faz parte das estratégias organizacionais. / This work has as objective to study as the virtual processes are being integrated in the organizacionais strategies of the chemical companies. The virtual process engloba all organizacionais activities, since marketing, vendas, distribution, services to the customer and support after venda. One used two theoretical models for evaluation of the organizacionais aspects. Results of the research had shown that it did not have a clear definition for the use of virtual processes and its adoption is not part of the organizacionais strategies.
|
45 |
Caracterização de dispositivos eletrônicos para dosimetria em tomografia computadorizada / Characterization of electronic devices for dosimetry in computed tomographyPaschoal, Cinthia Marques Magalhães 12 March 2012 (has links)
Computed tomography (CT) is an examination of high diagnostic capability that delivers high doses of radiation compared with other diagnostic radiological examinations. The
current CT dosimetry is mainly made by using a 100 mm long ionization chamber. However, it was verified that this extension, which is intended to collect all scattered radiation of the single slice dose profile in CT, is not enough. An alternative dosimetry has been suggested by translating smaller detectors. In this work, commercial electronics devices of small dimensions were characterized for CT dosimetry. The project can be divided in five parts: a) pre-selection of devices; b) electrical characterization of selected devices; c) dosimetric characterization in laboratory, using radiation qualities specific to CT, and in a tomograph; d) evaluation of the dose profile in CT scanner (free in air and in head and body dosimetric phantom); e) evaluation of the
new MSAD detector in a tomograph. The selected devices were OP520 and OP521 phototransistors and BPW34FS photodiode. Before the dosimetric characterization, three
configurations of detectors, with 4, 2 and 1 OP520 phototransistor working as a single detector, were evaluated and the configuration with only one device was the most adequate. Hence, the following tests, for all devices, were made using the configuration with only one device. The
tests of dosimetric characterization in laboratory and in a tomograph were: energy dependence, response as a function of air kerma (laboratory) and CTDI100 (scanner), sensitivity variation and angular dependence. In both characterizations, the devices showed some energy dependence, indicating the need of correction factors depending on the beam energy; their response was linear with the air kerma and the CTDI100; the OP520 phototransistor showed the largest variation in
sensitivity with the irradiation and the photodiode was the most stable; the angular dependence was significant in the laboratory and less expressive in tomography due to geometry of the X ray beams. Since the photodiode device was the most stable, the majority of the following tests, was made only with the BPW34FS. In the evaluation of the dose profile in CT, it was confirmed that the extension of 100 mm of the chamber pencil is not enough to collect all of the scattered
radiation of the dose profile. Furthermore, it was shown that the detectors are able to obtain details of the dose profile and, thereby, estimate quantities in CT dosimetry. The new MSAD detector, which consists of a row of 31 BPW34FS photodiodes, presents an advantage in comparison to other detectors used to obtain the MSAD, through multiple slices, and the CTDI, through a single slice: the possibility of obtaining isolated (one slice) or adjacent (various slices)
dose profiles in detail and in real time, and the possibility of calculating dosimetric quantities using an electronic system and computer programs, simplifying the dosimetry in CT. / A tomografia computadorizada (CT) é um exame de alta capacidade de diagnóstico que proporciona doses de radiação elevadas se comparado com outros exames de diagnóstico
radiológico. A dosimetria atual em CT é feita, principalmente, utilizando uma câmara de ionização tipo lápis de 100 mm de extensão. No entanto, verificou-se que essa extensão, que tem o intuito de coletar toda radiação espalhada do perfil de dose de um único corte em tomografia, não é suficiente. Uma forma alternativa de dosimetria tem sido sugerida através da translação de detectores menores. Neste trabalho, dispositivos eletrônicos comerciais de pequenas dimensões
foram caracterizados para dosimetria em tomografia. O projeto pode ser dividido em cinco partes: a) pré-seleção dos dispositivos; b) caracterização elétrica dos dispositivos escolhidos; c) caracterização dosimétrica no laboratório, utilizando qualidades de radiação específicas para CT, e em um tomógrafo; d) avaliação do perfil de dose em CT em um tomógrafo (no ar e em simuladores dosimétricos de cabeça e de abdômen); e) avaliação do novo detector de MSAD em
um tomógrafo. Os dispositivos escolhidos foram os fototransistores OP520 e OP521 e o fotodiodo BPW34FS. Antes da caracterização dosimétrica, três configurações de detectores, com 4, 2 e 1 fototransistor OP520 funcionando como um único detector, foram avaliadas e a configuração com apenas 1 dispositivo foi a mais adequada. Por isso, os testes seguintes, para todos os dispositivos, foram realizados com a configuração com apenas 1 dispositivo. Os testes
da caracterização dosimétrica no laboratório e no tomógrafo foram: dependência energética, resposta em função do kerma no ar (laboratório) e do CTDI100 (tomógrafo), variação de
sensibilidade e dependência angular. Nas duas caracterizações, os dispositivos apresentaram certa dependência energética, indicando a necessidade de fatores de correção a depender da energia do feixe; a resposta deles foi linear com o kerma no ar e com o CTDI100; o fototransistor
OP520 foi o que apresentou maior variação de sensibilidade com a irradiação e o fotodiodo foi o mais estável; e a dependência angular foi expressiva no laboratório e pouco expressiva no tomógrafo, devido às geometrias dos feixes. Como o fotodiodo foi o dispositivo mais estável, os testes seguintes, em sua maioria, foram feitos somente com o BPW34FS. Na avaliação do perfil de dose em CT, confirmou-se que a extensão de 100 mm da câmara lápis não é suficiente para coletar toda radiação espalhada do perfil de dose. Além disso, foi mostrado que os detectores são capazes de obter detalhes do perfil de dose e, com isso, estimar grandezas dosimétricas em CT. O novo detector de MSAD, que consiste em um detector com 31 fotodiodos BPW34FS enfileirados, apresenta um diferencial em relação a outros detectores que são utilizados para obter o MSAD, a partir de vários cortes tomográficos, e o CTDI, através um único corte: é a
possibilidade de obtenção de perfis de dose isolados (um único corte) ou adjacentes (vários cortes) com detalhes e em tempo real, e a possibilidade do cálculo de grandezas dosimétricas utilizando um sistema eletrônico e programas computacionais, podendo, assim, simplificar a
dosimetria em tomografia.
|
46 |
Estudo sobre o uso do relé de estado sólido em aplicações de ripple counter considerando as variações de temperatura da junção / The usage of solid-state relay considering the junction temperature variations on ripple counter applicationsGarcia, Alexandre David Rinco 17 August 2018 (has links)
Orientador: José Antonio Siqueira Dias / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-17T22:39:39Z (GMT). No. of bitstreams: 1
Garcia_AlexandreDavidRinco_M.pdf: 2843880 bytes, checksum: ecc88d93aeb48f3dad51bc6b4d4fe6f4 (MD5)
Previous issue date: 2011 / Resumo: Neste trabalho é apresentado um estudo que visa otimizar os sistemas de ripple counter mediante a utilização de relés de estado sólido (FET). Com a utilização de relés de estado sólido para ripple counter é possível não apenas economizar recursos com a montagem do circuito, mas também inserir proteções inerentes ao FET. Este trabalho também mostra que é possível compensar as variações de camada devidas ao aumento da temperatura. Os sistemas atuais utilizam relés comuns e circuitos agregados; este trabalho demonstra que o uso de relés de estado sólido em aplicações de ripple counter, considerando as variações de temperatura da junção, é, não apenas viável, como também uma solução que agrega maior valor ao produto / Abstract: In this work a deep study to optimize ripple counter systems utilizing solid state relays (FET) is presented. The usage of solid relay for ripple counter will be possible not only saving money on external circuits but also inserting inherent protection's FET. This work shows that is possible to compensate the layer variations due to temperature's increasing. The currently systems use common relays and aggregates circuits, but the description above demonstrates that the usage of solid-state relay in ripple counter applications considering the junction temperature variations is not only feasible but also a better solution / Mestrado / Eletrônica, Microeletrônica / Mestre em Engenharia Elétrica
|
47 |
Avaliação de novas tecnologias para otimização de desenvolvimento do produto / Valuation of new technologies to optimization of the development of productPinardi, Emerson Roberto 05 February 2005 (has links)
Orientador: Sergio Tonini Button / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-05T06:48:27Z (GMT). No. of bitstreams: 1
Pinardi_EmersonRoberto_M.pdf: 2980822 bytes, checksum: d3b98a4a8570258311e79f8b2c9806f5 (MD5)
Previous issue date: 2005 / Resumo: O objetivo desse trabalho é otimizar as fases de desenvolvimento de produto buscando reduzir principalmente o tempo e os custos envolvidos nas mesmas. Como o desenvolvimento é uma atividade muito ampla, que pode ser dividido basicamente em cinco fases: planejamento, desenvolvimento do projeto, desenvolvimento do processo, manufatura, melhoria contínua. Esse trabalho concentrou-se na fase de projeto, mais especificamente no processo de distribuição de desenho de produto gerado na Engenharia, o qual é utilizado em diversos setores das unidades fabris. O desafio foi gerar um sistema informatizado para distribuição do desenho de produto, o qual pode ser gerado a partir de 4 sistemas de CAD diferentes dependendo da disponibilidade de sistema e qual a interface necessária para atender o cliente. Após a criação do novo sistema de distribuição de desenho, comparou-se com a metodologia convencional aplicada até então, baseada em cópia de papel e distribuição via correio interno, indicando os ganhos e os possíveis inconvenientes surgidos. Os resultados obtidos mostram como essa nova metodologia de distribuição de desenho informatizado diminuiu os gastos com a geração de cópias, o tempo de trânsito da informação, bem como a facilidade de acesso à mesma / Abstract: The objective of this work is optimize the phases of product development, reduce the main time and the cost involved in itself. Like the development is a wide activity, that can be divided in five basic phases: planning, development of project, development of process, manufacturing, continued increase. Emphasized only in project phase, to increase the specific process of distribution of product drawing made by Engineering, and itself is utilized in many departments of the several units the same company. The challenge was create a computer system to distribution of drawing product, itself can be made in four different CAD systems as according as availability the system and which interface were necessary to attend the customer. After made the new system of drawing distribution, compared with a conventional methodology applied nowadays, which was based in paper copy and distribution by internal mail, showing the profit and the possible inconvenience that could happen. The results show like this new methodology to distribution of electronic drawing lows the cost with the copy drawing, time of the information circulate, and the facility to access electronic drawings / Mestrado / Materiais e Processos de Fabricação / Mestre em Engenharia Mecânica
|
48 |
Tecnicas de otimização do mergesort externo num ambiente de banco de dados / External mergesort optimization strategies in a database environmentFanelli, Elton Gustavo 23 February 2006 (has links)
Orientador: Rogerio Drummond / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Computação / Made available in DSpace on 2018-08-06T04:55:54Z (GMT). No. of bitstreams: 1
Fanelli_EltonGustavo_M.pdf: 1448895 bytes, checksum: 513ab9546abfaae1b9d4c5ba4ab6fa2e (MD5)
Previous issue date: 2006 / Mestrado / Banco de Dados, Analise de Algoritmos e Complexidade / Mestre em Ciência da Computação
|
49 |
Estudo e implementação da otimização de Preload de dados usando o processador XScale / Study and implementation of data Preload optimization using XScaleOliveira, Marcio Rodrigo de 08 October 2005 (has links)
Orientador: Guido Costa Souza Araujo / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Computação / Made available in DSpace on 2018-08-06T14:27:52Z (GMT). No. of bitstreams: 1
Oliveira_MarcioRodrigode_M.pdf: 1563381 bytes, checksum: 52e2e029998b3539a26f5c2b76284d88 (MD5)
Previous issue date: 2005 / Resumo: Atualmente existe um grande mercado para o desenvolvimento de aplicações para sistemas embutidos, pois estes estão fazendo parte crescente do cotidiano das pessoas em produtos de eletrônica de consumo como telefones celulares, palmtop's, agendas eletrônicas, etc.
Os produtos de eletrônica de consumo possuem grandes restrições de projeto, tais como custo reduzido, baixo consumo de potência e muitas vezes alto desempenho. Deste modo, o código produzido pelos compiladores para os programas executados nestes produtos, devem executar rapidamente, economizando energia de suas baterias. Estes melhoramentos são alcançados através de transformações no programa fonte chamadas de otimizações de código. A otimização preload de dados consiste em mover dados de um alto nível da hierarquia de memória para um baixo nível dessa hierarquia antes deste dado ser usado. Este é um método que pode reduzir a penalidade da latência de memória. Este trabalho mostra o desenvolvimento da otimização de preload de dados no compilador Xingo para a plataforma Pocket PC, cuja arquitetura possui um processador XScale. A arquitetura XScale possui a instrução preload, cujo objetivo é fazer uma pré-busca de dados para a cache. Esta otimização insere (através de previsões) a instrução preload no código intermediário do programa fonte, tentando prever quais dados serão usados e que darão miss na cache (trazendo-os para esta cache antes de seu uso). Com essa estratégia, tenta-se minimizar a porcentagem de misses na cache de dados, reduzindo o tempo gasto em acessos à memória. Foram usados neste trabalho vários programas de benchmarks conhecidos para a avaliação dos resultados, dentre eles destacam-se DSPstone e o MiBench. Os resultados mostram que esta otimização de preload de dados para o Pocket PC produz um aumento considerável de desempenho para a maioria dos programa testados, sendo que em vários programas observou-se uma melhora de desempenho maior que 30%! / Abstract: Nowadays, there is a big market for applications for embedded systems, in products as celIular phones, palmtops, electronic schedulers, etc. Consumer electronics are designed under stringent design constraints, like reduced cost, low power consumption and high performance. This way, the code produced by compiling programs to execute on these products, must execute quickly, and also should save power consumption. In order to achieve that, code optimizations must be performed at compile time. Data preload consists of moving data from a higher leveI of the memory hierarchy to a lower leveI before data is actualIy needed, thus reducing memory latency penalty. This dissertation shows how data preload optimization was implemented into the Xingo compiler for the Pocket PC platform, a XScale based processor. The XScale architecture has a preload instruction, whose main objective is to prefetch program data into cache. This optimization inserts (through heuristics) preload instructions into the program source code, in order to anticipate which data will be used. This strategy minimizes cache misses, allowing to reduce the cache miss latency while running the program code. Some benchmark programs have been used for evaluation, like DSPstone and MiBench. The results show a considerable performance improvement for almost alI tested programs, subject to the preload optimization. Many of the tested programs achieved performance improvements larger than 30% / Mestrado / Otimização de Codigo / Mestre em Ciência da Computação
|
50 |
Percussão multipla mediada por processos tecnologicos / Multiple percussion mediated by technologyCampos, Cleber da Silveira 27 June 2008 (has links)
Orientador: Jonatas Manzolli / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Artes / Made available in DSpace on 2018-08-11T14:15:29Z (GMT). No. of bitstreams: 1
Campos_CleberdaSilveira_M.pdf: 2155100 bytes, checksum: af5265e9405b60be69b18a473dfc3990 (MD5)
Previous issue date: 2008 / Resumo: Este trabalho propõe uma reflexão teórica e um estudo prático sobre a interpretação dos instrumentos de percussão e mediação tecnológica. O texto tem por objetivo discutir o repertório e a postura interpretativa do músico, relacionando obras para instrumentos de percussão e interfaces tecnológicas. Há uma contextualização histórica dos processos tecnológicos da música do século XX e uma reflexão sobre a construção do material sonoro, do gesto musical e das configurações instrumentais. Discutem-se os processos de mediação envolvidos na execução do repertório para percussão múltipla interativa e analisam-se obras que empregam processos tecnológicos como eletrônicos ao vivo, interfaces, recursos audiovisuais e cênicos. A metodologia utilizada nessa pesquisa foi vinculada a Oficinas de Interação onde foram estudados novos parâmetros de execução musical. Aliou-se técnica tradicional aos protótipos de novas interfaces que foram criadas e aplicadas à pratica instrumental do autor. Foram desenvolvidas, ainda, novas estratégias interpretativas em que se buscou um maior entendimento e amadurecimento da interação da técnica instrumental com
os diversos recursos de mediação tecnológica. Por fim, uma reflexão foi empreendida sobre as diferentes linguagens e meios envolvidos nos processos interpretativos, além da apresentação do conjunto de obras executadas e analisadas a partir do ponto de vista interpretativo / Abstract: This dissertation presents a theoretical view point and a practical study on percussion interpretation under technological mediation. It compares repertoire and performance perspectives relating pieces for percussion instruments and technological interfaces. There is a historical contextualization concerning to technological processes used in the Twenty Century Music and a discussion on design of sound material, musical gesture and instrumental set-ups. Mediation processes related to repertoire performance for interactive multiple percussion are discussed, and pieces involving technological processes such as live electronics,
interfaces, audiovisuals and scenic resources are analyzed. Research methodology was based on interactive workshops in which new music performance perspectives were studied. Traditional techniques were linked to new interfaces prototypes enhancing author¿s instrumental practices. New interpretation strategies were developed aiming to enlarge understanding on interpretation and
interaction with instrumental techniques and diverse technological mediation resources. Different languages and medium related to these performance processes were also studied. Finally, a set of pieces performed and analyzed under an interpretative point of view is presented. / Mestrado / Mestre em Música
|
Page generated in 0.0658 seconds