• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 125
  • 8
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 1
  • 1
  • Tagged with
  • 135
  • 73
  • 63
  • 45
  • 40
  • 27
  • 23
  • 20
  • 17
  • 16
  • 15
  • 14
  • 14
  • 13
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Posicionamento do componente acetabular na artroplastia total do quadril com e sem o auxílio de um sistema de navegação computadorizado: estudo comparativo prospectivo randomizado / Acetabular component positioning in total hip arthroplasty with and without a computer-assisted system: a prospective, randomised and controlled study

Gurgel, Henrique Melo de Campos 06 July 2011 (has links)
Em um estudo prospectivo e randomizado sobre o posicionamento do componente acetabular na artroplastia total do quadril, 20 quadris foram operados com o auxílio da navegação livre de métodos de imagem e 20 quadris foram operados através do método convencional. Todas as cirurgias foram realizadas pelo mesmo cirurgião com o paciente em decúbito lateral. A avaliação do posicionamento foi feita através da medição tomográfica pós-operatória dos ângulos de anteversão e inclinação cirúrgicos e análise da zona de segurança. Os resultados obtidos foram similares em todas as comparações: anteversão média de 17,4o no grupo navegado e 14,5o no grupo convencional (p=0,215), inclinação média de 41,7o no grupo navegado e 42,2o no grupo convencional (p=0,633), desvio médio do objetivo da anteversão (15o) de 5,5o no grupo navegado e 6,6o no grupo convencional (p=0,429), desvio médio do objetivo da inclinação (40o) de 3o no grupo navegado e 3,2o no grupo convencional (p=0,783) e localização dentro da zona de segurança de 90% no grupo navegado e 80% no grupo convencional (p=0,661). A avaliação tomográfica pós-operatória do posicionamento acetabular na artroplastia total de quadril realizada com o paciente em decúbito lateral foi semelhante ao se comparar a técnica navegada com a técnica convencional / In a prospective and randomised study of the acetabular component position in total hip arthroplasty, 20 hips were operated using imageless navigation and 20 hips were operated using the conventional method. The same surgeon performed all the operations with the patient in the lateral position. The correct position of the acetabular component was evaluated with computed tomography performed after the surgeries, measuring the operative anteversion angle and the operative inclination angle and determining the cases inside the safe zone. The results were similar in all the analyses: a mean anteversion of 17.4o in the navigated group and 14.5o in the conventional group (p=0.215), a mean inclination of 41.7o in the navigated group and 42.2o in the conventional group (p=0.633), a mean deviation from the desired anteversion (15o) of 5.5o in the navigated group and 6.6o in the conventional group (p=0.429), a mean deviation from the desired inclination (40o) of 3o in the navigated group and 3.2o in the conventional group (p=0.783), and location inside the safe zone of 90% in the navigated group and 80% in the conventional group (p=0.661). The acetabular component positions tomography analyses in total hip arthroplasty, performed with the patient in the lateral position, were similar whether using imageless navigation or performing it conventionally
32

Comparação clínica, laboratorial e densitométrica de pacientes com coxartrose e fraturas do colo femoral

Spinelli, Leandro de Freitas January 2016 (has links)
Resumo não disponível.
33

Estudo da osteonecrose no processo de usinagem da cabeça do fêmur utilizando um dispositivo mecânico de furação / Study of the osteonecrosis in the process of femur head machining by a mechanical drilling device

Higashi, Rosemeire Rosa 12 September 2014 (has links)
A utilização de implantes cirúrgicos para artroplastia de quadril com prótese de recapeamento da cabeça femoral como substituto ósseo é um procedimento que tem sido realizado em 35% dos casos de Osteoartrose nos EUA. Entretanto, o atrito da broca e o aumento da temperatura durante a usinagem da cabeça femoral são responsáveis pelo possível aquecimento do tecido ósseo, podendo provocar a necrose óssea térmica. Neste sentido, o desenvolvimento de novos ferramentais e metodologias para minimizar os danos térmicos do atrito torna-se importante. Diante disso, o presente estudo teve como objetivo verificar se há a ocorrência de necrose óssea em um procedimento de furação óssea utilizando o dispositivo EQUITRON; Mod.ES 2200, desenvolvido no LTC-EESC-USP. Para tal, utilizamos 4 amostras de costela bovina removidas após a morte do animal, que foram furadas com broca de aço inoxidável (HSS-SKF), de 8 milímetros, sem irrigação externa. As amostras foram furadas com rotações de 100, 1000, 1200 e 2500 RPM, aferidas por tacômetro foto/contato digital da marca MINIPA, MDT-2238, e com avanço controlado de 80 mm/min (dispositivo da marca-EQUITRON; MOD.ES 2200; RPM 2800; Potência 0,30; Torque 1,6 Nm). Foram mensuradas as temperaturas iniciais da broca e da amostra e a final da amostra com termômetro digital, marca-MEDISANA®. Após a furação foram confeccionadas lâminas histológicas (HE) do tecido ósseo, preparadas de acordo com a metodologia apropriada, para posterior qualificação e quantificação da ocorrência de necrose óssea térmica através de imagens captadas por microscopia óptica (Olympus BX 41TF - Made Japan) utilizando-se o programa Motic Images Plus 2.0 para a captura das imagens. Os valores de temperaturas aferidos na amostra após a furação apresentaram relação positiva com a RPM utilizada, isto é, quanto maior a rotação, maior foi a temperatura observada. Apenas a amostra furada a 2500 RPM ultrapassou a temperatura de referencia para a gênese da osteonecrose térmica, que é de 47ºC. As análises histológicas apresentaram uma baixa predominância de células picnóticas e lacunas, sugerindo menor dano tecidual. Os resultados obtidos no presente estudo sugerem que o dispositivo (furadeira) desenvolvido no LTC-EESC-USP para a realização das furações nas amostras ósseas em testes de bancada foi eficiente em minimizar a ocorrência de necrose óssea térmica, até mesmo em condições de temperatura acima do limite fisiológico aceitável. / The utilization of surgical implants for hip arthroplasty with a resurfacing prosthesis of the femoral head as a bone substitute have been conducted in 35% of osteoarthrosis cases in the USA. However, the friction of the drill and the increase in the temperature during the machining of the femoral head can possibly heat the bony tissue and provoke a thermal bone necrosis. The development of new tools and methodologies for minimizing the thermal damage of the friction has become fundamental. The present study analyzes the occurrence of bone necrosis in a procedure of bone drilling that uses an EQUITRON device, Mod. ES 2200, developed at the LTC-EESC-USP. Four samples of bovine ribs removed after the death of the animal were used for the tests. They were drilled by an 8mm stainless-steel drill (HSS-SKF) with no external irrigation, at 100, 1000, 1200 and 2500 RPM calibrated by a MINIPA, MDT-2238 digital photo/contact tachometer and whose 80mm/min. advance (EQUITORN device; MOD.ES 2200; RPM 2800; 0.30 Potency and 1,6Nm torque) was controlled. The initial temperatures of the drill and the sample and the final temperature of the sample were measured by a MEDISANA digital thermometer. After drilling, histological blades (HE) were produced from the bony tissue and prepared according to the adequate methodology for further qualification and quantification of the occurrence of thermal bone necrosis through images captured by optical microscopy (Olympus BX 41TF - made in Japan) and Motic Images Plus 2.0 program. The values of the temperatures measured in the sample after drilling showed a positive relation with the RPM utilized, i.e., the faster the rotation, the higher the temperature. Only the sample drilled at 2500RPM exceeded the reference temperature (47ºC) for the genesis of the thermal osteonecrosis. The histological analyses revealed a low predominance of picnotic cells and gaps, which suggest minor tissue damage. The results show the device (drilling machine) developed at the LTC-EESC-USP for the drilling in the bone samples in workbench tests is efficient to minimize the occurrence of thermal bone necrosis, even at temperatures above the physiological acceptable limit.
34

Estudo numérico e experimental da biomecânica do fémur intacto e com prótese de anca inserida : Biomecânica da anca

Guedes, José Américo da Silva January 2000 (has links)
Disertação apresentada para obtenção do grau de Mestre em Engenharia Biomédica, na Faculdade de Engenharia da Universidade do Porto, sob a orientação do Professor Doutor José António de Oliveira Simões
35

Análise numérica da interface osso - cimento na artroplastia da anca

Nabais, Cláudia Raquel Jeca dos Ovos Dias January 2006 (has links)
Tese de mestrado. Engenharia Biomédica. 2006. Faculdade de Engenharia. Universidade do Porto, Universidade de Aveiro. Departamento de Engenharia Mecânica
36

Aprovechamiento de los recursos sanguíneos en la artroplastia primaria de rodilla

Biarnés Suñé, Alfons 30 June 2005 (has links)
A pesar de que la transfusión cada vez es más segura, no está exenta de riesgos. Por ello es importante tener una buena estrategia transfusional. El objetivo de este estudio es desarrollar un modelo logístico para predecir la posibilidad de transfusión sanguínea en la artroplastia primaria de rodilla; con el fin de facilitar la elaboración de un algoritmo transfusional. Material y métodos: Estudio prospectivo de 134 pacientes intervenidos de artroplastia primaria de rodilla unilateral realizados entre el 1 de Abril y el 30 de junio del 2003. Las variables fueron analizadas para determinar su asociación univariante con la transfusión sanguínea postoperatoria. Los factores más significativos fueron introducidos en una regresión logística múltiple. Posteriormente se han obtenido las diferentes curvas ROC y se ha calculado el área bajo la curva ROC con el fin de obtener el modelo con mejor poder predictor. Resultado: La asociación de la hemoglobina inicial con el peso del paciente ha obtenido la mejor área bajo la curva ROC (0,805; IC: 0,714 - 0,896). El modelo es: Probabilidad (p) = 1/ (1+e-Z) donde Z =14,960 - 1,008 x Hemoglobina inicial (g/dl) - 0,03 x Peso (Kg). Conclusión: Las variables predictoras que más influyen en la transfusión alogénica después de la artroplastia total primaria de rodilla son la hemoglobina inicial y el peso. Por lo tanto, en el algoritmo uno de nuestros objetivos iniciales es mejorar, si es factible, la hemoglobina preoperatoria. / Even when the blood transfusion is becoming safer, it is still not full free of risks. For that reason it is important to have a good transfusional strategy. The objective of this study was to develop a logistic model to predict the likelihood of blood transfusion in primary total knee arthroplasty; with the purpose of facilitating the preparation of a transfusional algorithm. Material and methods: A prospective study of 134 patients who underwent primary unilateral total knee arthroplasty was performed between April 1st and June 30th 2003. The variables were analysed to determine their univariate association with postoperative blood transfusion. Significant factors were entered into a multiple logistic regression model. Subsequently we obtained the different ROC curves and calculated the area under ROC curve with the purpose of obtaining the strongest predictors model. Result: The association between the initial hemoglobin and the patient's weight has obtained the best area under ROC curve (0.805; CI: 0.714 - 0.896). The model is: Probability (p) = 1/(1+e-Z) where Z =14,960 - 1.008 x initial Hemoglobin (g/dl) - 0.03 x weight (kg). Conclusion: The strongest predictors for allogenic transfusion after total knee arthroplasty are the initial hemoglobin values and the patient's weight. Therefore, in algorithm one of our initial objectives is to improve, if possible, the preoperative hemoglobin.
37

Factores predictivos transfusionales en la artroplastia total de cadera

González Posada, Miguel Ángel 16 April 2012 (has links)
Dentro de las especialidades quirúrgicas que necesitan más recursos hemáticos se encuentra la cirugía ortopédica. La artroplastia total de cadera (ATC) es una de las más sangrantes con unas pérdidas cercanas a los 2000 ml según el mayor registro europeo para este tipo de cirugía .Ante tal nivel de sangrado y la necesidad, en ocasiones, de administrar sangre se nos plantea el potencial problema de los riesgos asociados a la transfusión. El potencial daño de una estrategia de transfusión liberal está demostrada por lo que en el momento de indicar una transfusión sanguínea, el médico debe de ser muy consciente de que está utilizando un recurso escaso y con potenciales peligros asociados. A pesar de los avances en la anestesiología y en la reanimación de pacientes críticos, los actos quirúrgicos se han visto acompañados de un aumento de las demandas de hemoderivados. Este hecho, desafortunadamente, no se acompaña de un aumento significativo de las donaciones. En España el índice de donaciones en el 2010 fueron de 38,63 por 1.000 habitantes y en Cataluña fue de 38,86 por 1.000 habitantes, por lo que estamos ante el uso de un recurso caro y limitado. Por lo tanto todo procedimiento que nos ayude a planificar un adecuado uso de recursos hemáticos o la disminución de las transfusiones es de claro interés clínico en la práctica asistencial diaria. El objetivo de la tesis ha sido establecer un modelo predicativo sobre las transfusiones en un proceso quirúrgico frecuente en nuestro medio y por tanto con impacto en el consumo de hemoderivados. Al ser un proceso programado, la planificación de estos recursos hemáticos es totalmente factible siendo por lo tanto tributario de mejoras continuas en su asistencia y debería de ser uno de los objetivos de los servicios implicados. El resultado nos arroja que en nuestro medio la cifras de hemoglobina, el género y el peso son los factores más vinculados entre sí para determinar la probabilidad que tiene cada paciente de ser transfundido en la cirugía por artroplastia de cadera.
38

Utilitat de la histologia en el diagnòstic de la infecció de l’artroplàstia de maluc

Bori i Tuneu, Guillem 27 April 2010 (has links)
Aquesta tesi està dedicada a l’estudi de la utilitat del nombre de leucòcitspolimorfonuclears en els teixits periprotètics pel diagnòstic de la infecció, a determinarquin es el punt de tall per definir infecció i a estudiar quina relació hi ha entre el númerode leucòcits polimorfonuclears trobats en les membranes periprotètiques i elmicroorganisme aïllat en els cultius convencionals.El primer objectiu avalua la utilitat de la histologia segons el criteri de Mirra iadaptat per Feldman (≥5 leucòcits polimorfonuclears per camp de gran augment) en tressituacions; recanvi protètic per sospita d’afluixament asèptic, per sospita d’afluixamentsèptic o reimplantació d’una pròtesi després d’un primer temps sèptic. En el cas delrecanvi per afluixament asèptic i en el moment de la reimplantació d’una pròtesi desprésd’un primer temps sèptic, la histologia presenta una sensibilitat baixa per tald’identificar una infecció. En canvi en el cas d’un recanvi amb la sospita d’afluixamentsèptic, la histologia es mostra com un test vàlid, ja que en la majoria de les situacionsconfirma aquesta sospita preoperatòria.El segon objectiu estudia si un punt de tall més baix (≥1 leucòcitspolimorfonuclears per camp de gran augment) és més eficaç en el diagnòstic de lainfecció. El resultat demostra que aquesta modificació fa que la histologia sigui méssensible però comporta un descens de l’especificitat.El tercer objectiu analitza la relació entre el número de leucòcitspolimorfonuclears i el tipus de microorganisme aïllat. L’aïllament d’estafilococscoagulasa-negativa es va associar a una menor infiltració de leucòcits polimorfonuclearsen els teixits periprotètics que amb altres microorganismes com Staphylococcus aureuso Bacils Gram-negatius com Escherichia coli o Pseudomonas spp.
39

Simulação numérica através do método dos elementos finitos e comparação experimental para obtenção de tensões e deformações específicas em fêmur com prótese total de quadril / Numerical simulation through the finite element method for obtaining and experimental comparison of stress and strain in specific femur with total hip prosthesis

Queiroz, Liana Paula [UNESP] 22 July 2014 (has links) (PDF)
Made available in DSpace on 2015-03-03T11:52:41Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-07-22Bitstream added on 2015-03-03T12:06:07Z : No. of bitstreams: 1 000807256.pdf: 2090404 bytes, checksum: e98aedf601cc2875175e327605dd346b (MD5) / As tensões atuantes no fêmur com prótese total de quadril devem ser compreendidas para a melhoria nos processos de fabricação, cirúrgicos e reabilitação de um paciente implantado refletindo em sua qualidade de vida após a cirurgia. Essa pesquisa tem por finalidade a modelagem e a simulação numérica das tensões e deformações específicas atuantes num conjunto fêmur-prótese a fim de avaliar o comportamento estrutural do fêmur e verificar as maiores tensões em sua diáfise medial após uma Artroplastia Total de Quadril (ATQ), através do Método dos Elementos Finitos (MEF) e a comparação dos dados obtidos na simulação com dados obtidos experimentalmente. A simulação foi realizada pelo software ANSYS® de acordo com as normas da ABNT para ensaios em próteses de quadril. Um conjunto osso-prótese foi submetido a um carregamento de até 1000 N na direção perpendicular ao eixo horizontal, na linha de inserção da prótese. Foram realizadas simulações considerando o conjunto com propriedades biológicas e ortotrópicas, sintéticas e isotrópicas, uma simulação considerando um fêmur intacto e isotrópico para comparação e um ensaio laboratorial em um conjunto formado por um fêmur sintético e uma prótese de liga de titânio, nas mesmas condições das simulações computacionais com o objetivo de comparar as deformações. Concluiu-se que a partir das condições impostas neste trabalho, as tensões em um conjunto osso-prótese são muito próximas das tensões em um fêmur intacto, possuindo as mesmas tendências no que se diz respeito às fraturas por carregamento / The stresses acting on the femur with total hip replacement should be understood to improvement in manufacturing, surgical and rehabilitation of a patient implanted processes reflecting on their quality of life after surgery. The research aims to model simulate computationally the forces acting on a femoral prosthesis set, to evaluate the structural behavior of the femur and checker the biggest stresses in your diaphysis after Total Hip Arthroplasty using the Finite Element Method (FEM). ANSYS software was used for the simulation. The conditions imposed in accordance with ABNT for hip prostheses trials were used in the process. A bone-prosthesis set was subjected to a load up to 1000 N in the perpendicular direction to the horizontal axis on the line of insertion of the prosthesis. Simulations were performed considering the set biological, orthotropic, synthetic and isotropic properties. Three computational simulations under the same conditions were performed in order to compare the deformations. A simulation considering an intact isotropic femur with the and a laboratory test of a set consisting of a synthetic femur and a titanium alloy femoral prosthesis. Based on the conditions imposed in this study we conclude that the stresses in a bone prosthesis set are very similar to a tension in an intact femur, having the same trends with respect to the loading fractures
40

Desenvolvimento e avaliação dos efeitos e segurança de um protótipo de órtese de quadril para pacientes submetidos a artroplastia de ressecção tipo girdlestone : relato de caso

Luz, Livia Lobel da January 2017 (has links)
A cirurgia de Girdlestone é um procedimento que altera o estilo de vida dos pacientes gerando alterações na postura, na marcha e nas atividades de vida diária. Nesse contexto, as órteses de quadril são utilizadas como um adjunto no processo de reabilitação favorecendo o tratamento terapêutico, contudo órteses específicas para estes pacientes não estão disponíveis no mercado nacional. Assim, o estudo teve como objetivo desenvolver e confeccionar um protótipo de órtese de quadril e avaliar os efeitos e a segurança do dispositivo na reabilitação funcional dessa população. A participante da pesquisa realizou o Protocolo Fisioterapêutico do Hospital de Clínicas de Porto Alegre associado ao uso do protótipo de órtese de quadril. Os efeitos da órtese na reabilitação funcional foram avaliados através do questionário Harris Hip Score, teste de caminhada dos seis minutos e escala visual analógica da dor. A segurança foi avaliada através da análise dos dados registrados no formulário de eventos adversos. O dispositivo é composto por duas partes: uma cinta abdominal e uma cinta que envolve a coxa ligadas por faixas elásticas ajustáveis as quais proporcionam conforto além de facilidade para colocação. O estudo gerou resultados indicativos de que o dispositivo apresentado é viável e pode ser utilizado como adjuvante na reabilitação. O modelo proposto agregou melhora do desempenho físico, do alívio de dor, da funcionalidade além de ser seguro. Além disso, este estudo ofereceu um modelo de tecnologia assistiva confeccionado com custo inferior aos importados para o mercado. Contudo, é necessário um estudo mais amplo para gerar conclusões significativas. / Girdlestone procedure is a surgical operation that causes lifestyle changes in patients followed by modifications in posture, gait and activities in everyday life. In this context, hip orthoses are used as an adjunct in the rehabilitation process supporting the therapeutic treatment. However, these devices are not available in the brazilian market. Thus, the study aimed to develop and make a prototype of a hip orthosis and to evaluate the effects and safety of the device in the functional rehabilitation of this population. The research participant performed the physiotherapeutic protocol of the Hospital de Clínicas de Porto Alegre associated to the use of the hip orthosis’ prototype. The effects of orthosis on functional rehabilitation were rated by using the Harris Hip score, six-minute walk test and visual analogue pain scale. Safety was rated by analyzing the data recorded on the adverse events form. The device consists of two parts: an abdominal strap and a thigh-wrapped strap attached by adjustable elastic straps which provide comfort and make it easy to apply the product. The results indicated that the device is suitable and can be used as an adjuvant in rehabilitation. The proposed model promoted improvement in physical performance, pain relief, functionality and it’s also safe. In addition, this research developed an assistive technology model made at a lower cost than those ones imported. However, a larger study is needed to produce more meaningful conclusions.

Page generated in 0.079 seconds