• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 65
  • 8
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 77
  • 25
  • 22
  • 13
  • 12
  • 11
  • 11
  • 10
  • 9
  • 8
  • 8
  • 7
  • 7
  • 7
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Eletrocardiografia pré-operatória em cães atendidos no Hospital Veterinário da Universidade Federal Rural de Pernambuco / Preoperative electrocardiogram evaluation in dogs within Metropolitan Area of Recife

FERREIRA, Cecília de Carvalho 26 February 2007 (has links)
Submitted by (edna.saturno@ufrpe.br) on 2016-08-12T12:05:48Z No. of bitstreams: 1 Cecilia de Carvalho Ferreira.pdf: 351028 bytes, checksum: ea340635e1ce19cdbd1c6940085b6d29 (MD5) / Made available in DSpace on 2016-08-12T12:05:48Z (GMT). No. of bitstreams: 1 Cecilia de Carvalho Ferreira.pdf: 351028 bytes, checksum: ea340635e1ce19cdbd1c6940085b6d29 (MD5) Previous issue date: 2007-02-26 / As important as the surgery itself is the preoperative evaluation pointing to assure the success of anaesthesia and minimize risks of complications in the postoperative period. In this context, the preoperative electrocardiogram is very important since certain arrhythmias increases anaesthesical risk. The aim of this research was to evaluate the prevalence and types of electrocardiographic that should be submitted to some surgery and its relation with the surgery recommendation, historical of heart disease, clinical signs of cardiopathy, obesity, age, sex and body size,by clinical and electrocardiographic exams. It was evaluated 474 dogs of different breeds, age and size, and male and female, recommended to different types of surgeries. The electrocardiogram was made using the traditional or computerized methods, were 46% of them presented changes, showing that it is high the changes in preoperative electrocardiogram. Where males were statically more attacked than females (p<0,05), and left ventricular enlargement was the most common feature (24,31%), it was not observed inclination to specifics arrhythmias in the recommended surgeries evaluated. “Mixed breed dogs” (MBD) represented 42,52% of the analyzed sample, and it was significantly (p<0,05) the proportion of obese MBD that presented changes compared to the non-obeses, what lead to conclude the association of high frequency of electrocardiographic changes to the body condition. There was no statistical significant difference to the presence of change in healthy patients led to castration and in ills send to varied surgeries, what make lead us to believe that it is necessary the evaluation independent of surgery indication. MBD that presented historical of heart disease, were the ones that presented more changes(p<0,01) and the same wasn’t observed in the population in general and in Poodles, stressing that this exam must be done even without the historic of heart disease. The same affirmative is truth to the presence of clinical signs of heart disease, according to what checked in the analyzed population (p>0,05). Concerning to the weight it was checked that there is no statistical significant difference between the groups: until 9,9kg (45,1%), 10kg to 20kg (47,8%) and over 20kg (45,3%). The same occur in the analysis of age in accordance with size, highlighting the importance of exam independent of weight and age. In conclusion it is often the electrographical changes in preoperative period, mainly in males, were the left ventricular enlargement is the most common feature and the electrocardiogram must be done as a preoperative exam, independent of age, body size, surgery recommendation, or clinical sign of heart disease, and specially in male dogs, obese MBD and in MBD with historical of cardiopathy aims to minimize the anesthetic risks and cardiovascular complications. / Tão importante quanto o procedimento cirúrgico em si é a avaliação pré-operatória dos pacientes, com a finalidade de assegurar o sucesso da anestesia e minimizar os riscos de complicações potenciais no pós-cirúrgico. Neste contexto, a avaliação eletrocardiográfica préoperatória é de suma importância uma vez que certas arritmias conferem riscos anestésicos aumentados. Objetivou-se com este trabalho avaliar a freqüência de alterações no eletrocardiograma de caninos atendidos no setor de cirurgia do HV/UFRPE e o tipo dessas anormalidades, bem como sua relação com a enfermidade cirúrgica, histórico de doença cardíaca, sinais clínicos de cardiopatia, obesidade, idade, sexo e porte, utilizando para isto, avaliação clínica e eletrocardiográfica. Foram avaliados 474 cães de raça, idade e porte variados, machos e fêmeas, encaminhados para procedimentos cirúrgicos diversos. O eletrocardiograma foi realizado por meio do método convencional ou computadorizado.Verificou-se que 46% dos cães apresentaram alterações,demonstrando ser alta a freqüência pré-operatória de alterações eletrocardiográficas, onde os machos foram estatisticamente mais acometidos que as fêmeas (p<0,05), e o aumento na duração do complexo QRS foi a alteração mais freqüentemente observada (24,31%), não tendo sido observada predisposição para o aparecimento de arritmias específicas em relação às enfermidades cirúrgicas avaliadas. Os cães sem raça definida (SRD) representaram 42,52% da amostra analisada, sendo significativo (p<0,05) a proporção de obesos SRD que apresentaram alterações comparadas aos não obesos, associando assim a elevada freqüência de alterações eletrocardiográficas à condição corpórea. Não houve diferença estatisticamente significativa para a presença de alterações em pacientes hígidos encaminhados para gonadectomias e em enfermos encaminhados para cirurgias diversas, levando a crer que é necessária essa avaliação independente da enfermidade cirúrgica. Nos cães SRD, aqueles com histórico de doença cardíaca foram os que mais apresentaram alterações (p<0,01), não sendo o mesmo observado para a população geral e de Poodles, ressaltando a importância da realização desse exame também nos que não apresentam histórico de cardiopatia, da mesma maneira, os cães que apresentaram sinais clínicos de doença cardíaca não necessariamente são os que mais apresentam alterações eletrocardiográficas (p>0,05). Com relação ao peso foi verificado que não há diferença estatisticamente significativa entre os grupos: até 9,9kg (45,1%), 10 a 20,0kg (47,8%) e com mais de 20,0kg (45,3%), ocorrendo o mesmo na análise da idade de acordo com o porte. Conclui-se que são freqüentes as alterações eletrocardiográficas no pré-operatório, onde o aumento na duração do QRS é a alteração mais observada, devendo o eletrocardiograma ser realizado como exame pré-operatório independente da idade, peso, enfermidade cirúrgica, ou sinais de cardiopatia ao exame clínico e, em especial nos cães machos, e nos sem raça definida que apresentem histórico de doença cardíaca ou sejam obesos, a fim de se obter maior segurança anestésica e menor risco de complicações cardiovasculares.
42

Taquiarritmia induzida por estimulação eletrica em atrios isolados de ratos : estudo de protocolos estimulatorios e mecanismos celulares

Zafalon Junior, Nivaldo 29 July 2018 (has links)
Orientadores: Rosana Almada Bassani, Jose Wilson Magalhães Bassani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-07-29T04:04:02Z (GMT). No. of bitstreams: 1 ZafalonJunior_Nivaldo_M.pdf: 1477869 bytes, checksum: a8b49631cb4b27db43e7230bfbf806b2 (MD5) Previous issue date: 2001 / Mestrado
43

Resposta inotropica a catecolaminas em miocitos ventriculares isolados de ratos submetidos a choque nas patas / Inotropic esponsiveness to catecholamines in ventricular myocytes isolated from footshock-stressed rats

Penna, Larissa Barretta 31 August 2007 (has links)
Orientador: Rosana Almada Bassani / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Biologia / Made available in DSpace on 2018-08-09T08:29:36Z (GMT). No. of bitstreams: 1 Penna_LarissaBarretta_M.pdf: 693702 bytes, checksum: 8dc2d8f7e3689a2bd6879211f15ccf07 (MD5) Previous issue date: 2007 / Resumo: Tem sido descrita supersensibilidade ao efeito cronotrópico do isoproterenol (ISO) em átrios direitos de ratos submetidos a choque nas patas, mas há pouca informação com relação à resposta inotrópica, principalmente ventricular. O objetivo deste trabalho foi estudar os efeitos inotrópico e pró-arrítmico de catecolaminas em miócitos ventriculares esquerdos de ratos nesta condição de estresse, em comparação a animais controles. Ratos Wistar machos adultos foram submetidos a sessões diárias de choque nas patas (30 min de duração) por 3 dias. Foram medidos o encurtamento celular de pico e a freqüência de contrações espontâneas das células. Obteve-se curvas concentração-efeito para noradrenalina (NA), ISO, 3-isobutil-1-metilxantina (IBMX) e CaCl2, com a determinação dos parâmetros Rmax (resposta máxima) e pD2 (-log da concentração do agonista que produz uma resposta= 0,5 Rmax). A população de receptores adrenérgicos (RA) _ foi analisada pelo método de Schild. Observamos, em células de animais do grupo choque, redução da Rmax inotrópica à NA e ao ISO. Estas diferenças permaneceram durante bloqueio de RA_1, mas foram abolidas pelo bloqueio de RA_1 (aumento da Rmax ao ISO apenas no grupo choque) ou _2 (redução da Rmax no apenas no grupo controle). O valor pA2 do metoprolol e a resposta inotrópica a IBMX e CaCl2 foram equivalentes entre os grupos. As células de ratos do grupo choque se mostraram mais reativas à ação pró-arrítmica da NA e do ISO, mas não aos demais agonistas. Todos os procedimentos que aboliram a redução de Rmax inotrópica a catecolaminas em miócitos de animais estressados também atenuaram as diferenças na resposta arrítmica a estes agonistas, o que pode indicar que a resposta inotrópica anormal no grupo choque seja conseqüência da maior atividade espontânea induzida pelas catecolaminas. Em conclusão, os resultados indicam que o estresse por choque nas patas causa aumento da reatividade de miócitos ventriculares de rato ao efeito pró-arrítmico de catecolaminas e reduz a eficácia aparente destes agonistas em estimular o inotropismo / Abstract: Supersensitivity to isoproterenol (ISO) chronotropic effect has been described in right atria from footshock-stressed rats, but information on inotropic responsiveness, particularly of the ventricles, is scarce. The goal of this study was to analyze the inotropic and pro-arrhythmic effect of catecholamines on left ventricular myocytes from footshockstressed rats, in comparison with cells from control animals. Adult male Wistar rats were submitted to 30-min long daily footshock sessions for 3 days. Peak cell shortening and the rate of spontaneous contractions during rest were measured in myocytes at 23 oC. Concentration-effect curves were obtained for noradrenaline (NA), ISO, 3-isobutyl-1- methylxanthine (IBMX) e CaCl2, for estimation of the following parameters Rmax (maximum response) and pD2 (-log of the agonist molar concentration that evokes halfmaximum response). The _ adrenoceptor (AR) population was analyzed by the Schild¿s method. In the footshock group, Rmax values to NA and ISO were decreased. This difference was unaffected by _1AR blockade, but was abolished by blockade of _1AR (which increased Rmax to ISO in the footshock group only) or _2-AR (which decreased Rmax to ISO solely in the control group). Metoprolol pA2 value and the inotropic responsiveness to IBMX and CaCl2 were similar in both groups. Cells from footshockstressed rats were more responsive to NA and ISO pro-arrhythmic action. All procedures that abolished the difference in inotropic response between footshock and control groups also diminished the differences in arrhythmic responses. These results indicate that the inotropic hyporesponsiveness to catecholamines in the footshock group may be the result of increased spontaneous activity induced by these agonists. We conclude that footshock stress enhances catecholamine pro-arrhythmic effect in rat ventricular myocytes, while simultaneously decreases the inotropic apparent efficacy of these agonists / Mestrado / Fisiologia / Mestre em Biologia Funcional e Molecular
44

Efeitos do ultrassom de potência sobre o coração = experimentos in vitro e in vivo = Effect of high power ultrasound on the heart : in vitro and in vivo experiments / Effect of high power ultrasound on the heart : in vitro and in vivo experiments

Coiado, Olívia Campos 20 August 2018 (has links)
Orientador: Eduardo Tavares Costa, Rosana Almada Bassani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-20T23:52:29Z (GMT). No. of bitstreams: 1 Coiado_OliviaCampos_D.pdf: 1523563 bytes, checksum: 0c49e56163206a06aa60778d17bb44bc (MD5) Previous issue date: 2012 / Resumo: Nos últimos anos, o uso do ultrassom em diagnóstico e terapia vem crescendo e novas técnicas vêm sendo aprimoradas e desenvolvidas para novos tipos de aplicações, como por exemplo, em tratamento alternativo de insuficiência cardíaca. O objetivo deste trabalho foi investigar efeitos biológicos (in vitro e in vivo) em decorrência de exposição do coração de ratos a ondas ultrassônicas (frequência central 1 MHz), a fim de identificar padrões de estimulação que possam ser deletérios ou que possam ser usados terapeuticamente para distúrbios do ritmo cardíaco. Nos experimentos in vitro 7 corações isolados perfundidos de ratas, foram estimulados por 30 s com bursts de intensidade variando entre 0,6 até 8,00 W. Foi observado efeito cronotrópico negativo (sem efeito inotrópico) mais consistente (15-20%) na frequência de estimulação de 3 Hz e intensidades entre 0,62 até 5,54 W, porém este efeito foi transitório e não dependeu do duty cycle utilizado. Observaram-se arritmias na presença do ultrassom, mas não houve variação significativa de temperatura. Nos experimentos in vivo foram utilizadas 20 ratas, os corações foram estimulados por 10 s com bursts de 2-3 MPa. Os experimentos in vivo foram divididos em 5 grupos cada um composto de 5 animais: 1) preliminar; 2) controle ultrassom; 3) ultrassom; 4) controle vagotomizado e 5) ultrassom vagotomizado. No grupo preliminar dos experimentos observou-se o efeito cronotrópico negativo do ultrassom (redução de ~7 % da frequência cardíaca basal logo após a aplicação do ultrassom), relatado previamente. Para os demais grupos, em que se tentou determinar uma possível variação na pressão arterial e a influência do sistema parassimpático sobre o efeito cronotrópico negativo, não foram observadas variações significativas das variáveis estudadas. Estudos adicionais são necessários para esclarecimento dos efeitos da aplicação do ultrassom de alta potência sobre o coração de ratos / Abstract: In recent years, the use of ultrasound in diagnosis and therapy is increasing and new techniques have been improved and developed for new applications as, for instance, in alternative treatment of heart failure. The goal of this study was to investigate the biological effects (in vitro and in vivo) on rat heart of ultrasound waves (1 MHz center frequency) in order to identify stimulatory patterns that may be damaging or that may be used therapeutically for heart rhythm disturbances. In the in vitro experiments, 7 isolated perfused rat hearts, were stimulated with ultrasound bursts for 30 s and intensity ranging from 0.6 to 8 W. Negative chronotropic effect was observed (without inotropic effect) more consistently (15-20%) at the stimulatory frequency of 3 Hz with intensities of 0.62 to 5.54 W but this effect was transient and not dependent on the duty cycle used. We observed arrhythmia in the presence of ultrasound, but no significant variation in temperature. In the in vivo experiments 20 rat hearts were stimulated for 10 s with ultrasound bursts of 2-3 MPa. The experiments were divided into five groups each consisting of 5 animals: 1) preliminary, 2) ultrasound control, 3) ultrasound, 4) vagotomy, control and 5) vagotomy, ultrasound. The preliminary group of experiments, we observed the negative chronotropic effect of ultrasound (~ 7% decrease in heart rate immediately after application of ultrasound), previously reported. In the other groups, in which we have tried to determine the possible variation in blood pressure and the influence of the parasympathetic system on the negative chronotropic effect, there were no significant changes in the variables studied. Additional studies are needed to clarify the effects of high power ultrasound application on rat heart / Doutorado / Engenharia Biomedica / Doutora em Engenharia Elétrica
45

Catequina e epicatequina minimizam a toxicidade induzida pela amiodarona em fibroblasto de pulmão humano (MRC-5)

Santos, Luciana Fernandes Silva 20 November 2015 (has links)
A amiodarona é um dos fármacos mais usados para o tratamento de arritmias cardíacas, tanto ventriculares como supraventriculares. Apesar de sua eficácia, o uso da amiodarona está associado a vários efeitos adversos, incluindo a toxicidade pulmonar. O mecanismo pelo qual a amiodarona causa lesão nas células pulmonares humanas não é inteiramente conhecido, mas estudos em cultura de células hepáticas humanas e pulmonares de ratos têm sugerido que a disfunção mitocondrial e o estresse oxidativo têm um papel importante na citotoxicidade da amiodarona. Os compostos fenólicos, incluindo catequina e epicatequina são amplamente distribuídos na natureza e conhecidos por sua capacidade de reduzir o estresse oxidativo. Além disso, alguns compostos fenólicos são capazes de modular a atividade mitocondrial. Em vista disso, o objetivo deste trabalho foi avaliar a capacidade dos compostos fenólicos catequina e epicatequina em a disfunção mitocondrial e os danos oxidativos causados pela amiodarona em células de fibroblasto de pulmão humano (MRC-5). Para atingir os objetivos as células MRC-5 foram tratadas com diferentes concentrações de catequina e epicatequina e após foram expostas a amiodarona 100 μM. A disfunção mitocondrial foi determinada através da atividade do complexo I da cadeia de transporte de elétrons e a biossíntese de ATP usando kits específicos. A viabilidade celular foi avaliada através do ensaio de 3-[4,5- dimetiltiazol 2-il]-2,5 difenil brometo de tetrazolina. A atividade das enzimas superóxido dismutase e catalase foram determinadas espectrofotometricamente. Os danos oxidativos a lipídeos e proteínas foram verificados através dos ensaios de substâncias reativas ao acido tiobarbitúrico e a proteínas carboniladas, respectivamente, e os níveis de óxido nítrico foram avaliados usando o método de Griess. Os resultados mostraram que a amiodarona inibiu a atividade do complexo I da cadeia de transporte de elétrons em 53% e a biossíntese de ATP em 9,5% e tanto a catequina como a epicatequina foram capazes de evitar estes efeitos em todas as concentrações (5, 10, 20 μM) testadas. Verificou-se que a amiodarona reduziu a atividade das enzimas superóxido dismutase e catalase (indicando produção de superóxido e peróxido de hidrogênio) e aumentou os danos oxidativos a lipídeos e proteínas. Os compostos fenólicos catequina e epicatequina foram capazes de minimizar as alterações no metabolismo redox induzidos pela amiodarona e aumentar a viabilidade nas células MRC-5. Catequina e epicatequina reduziram a depleção de óxido nítrico causada pela amiodarona. Este trabalho mostrou, pela primeira vez, que o mecanismo de toxicidade da amiodarona em células MRC-5 está associado à disfunção mitocondrial, principal causa de geração de dano oxidativo celular e que estes efeitos tóxicos são em parte reduzidos pela catequina e epicatequina. Embora outros estudos sejam necessários, estes dados abrem novas perspectivas para estudos visando o desenvolvimento de medicamentos que minimizem os efeitos tóxicos da amiodarona. / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, CAPES. / Amiodarone is among the most widely used drugs for the treatment of ventricular and supraventricular cardiac arrhythmias. However, the use of amiodarone is associated with several side effects including pulmonary toxicity. The mechanism of amiodarone toxicity is not well known, but studies in human liver cells and rats lung cells have been suggested that mitochondrial dysfunction and oxidative stress play important role in the amiodarone cytotoxicity. Phenolic compounds, including catechin and epicatechin are widespread in nature and known for their ability to reduce oxidative stress. In addition, some phenolic compounds are able to modulate mitochondrial activity. Therefore, the objective of this study was to evaluate the ability of phenolic compounds catechin and epicatechin to minimize the mitochondrial dysfunction and oxidative damage induced by amiodarone in human lung fibroblast cells (MRC-5). To achieve the objectives, MRC-5 cells were treated with different concentrations of catechin and epicatechin and then amiodarone 100 μM. Mitochondrial dysfunction was determined by the activity of complex I of the electron transport chain and ATP biosynthesis using specific kits. Cell viability was assessed by 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide assay. The activity of the enzymes superoxide dismutase and catalase were determined spectrophotometrically. The oxidative damage to lipids and proteins have been verified through the test substances reactive to the thiobarbituric acid and carbonyl protein, respectively, and nitric oxide levels were evaluated using the Griess method. The results showed that amiodarone inhibit 53% of the activity of complex I of the electron transport chain and 9.5% of ATP biosynthesis and both catechin and epicatechin were able to avoid these effects in all concentrations (5 10, 20 mM) tested. It was found that amiodarone reduced the superoxide dismutase and catalase activities (indicating the production of radicals superoxide and hydrogen peroxide) and increased oxidative damage to lipids and proteins. Phenolic compounds catechin and epicatechin were able to minimize alterations in the redox metabolism and increase in viability of MRC-5 cells. Furthermore, catechin and epicatechin reduced nitric oxide depletion caused by amiodarone. This study showed, for the first time, that toxicity of amiodarone in human lung cultured cells is associated, at least, in part, with mitochondrial dysfunction which was avoided by catechin and epicatechin. Although further studies are needed, these data open new perspectives for studies aiming the development of drugs that minimize the toxic effects of amiodarone.
46

Estudio de las modificaciones farmacológicas de los efectos electrofisiológicos producidos por el estiramiento local miocárdico a partir de técnicas dinámicas de cartografía eléctrica, en un modelo experimental de corazón aislado de conejo

CANTO SERRANO, IRENE DEL 31 March 2015 (has links)
La electrofisiología cardíaca permite el estudio de la actividad eléctrica de regiones específicas del corazón y, por tanto, el análisis de las modificaciones de sus características en regiones sometidas a cambios tales como el estiramiento miocárdico agudo. El estiramiento miocárdico modifica las propiedades electrofisiológicas de los cardiomiocitos, originando arritmias cardíacas en diferentes situaciones patológicas. Los efectos mecánicos del estiramiento inducen cambios relacionados con el calcio, y son varios los mecanismos que han sido implicados, incluyendo un incremento de la entrada de Na+ y la activación secuencial de los intercambiadores Na+/H+ y Na+/Ca2+ (modo inverso), ligados a eventos autocrino/paracrinos. Esta Tesis Doctoral tiene como principal objetivo el estudio de la posible participación de estos mecanismos en las respuestas electrofisiológicas al estiramiento mediante el análisis de las modificaciones farmacológicas de dichas respuestas. Se han estudiado las modificaciones de las características de la activación miocárdica durante la fibrilación ventricular (FV) y de las propiedades electrofisiológicas miocárdicas inducidas por el estiramiento miocárdico agudo en 44 corazones de conejo aislados y perfundidos en un sistema Langendorff, utilizando electrodos múltiples epicárdicos y técnicas de cartografía eléctrica, bajo condiciones control (n=9) y durante la perfusión del antagonista de los receptores tipo 1 de angiotensina II losartán 1µM (n=8), del antagonista de los receptores tipo A de endotelina BQ-123 0,1µM (n=9), del inhibidor del intercambiador Na+/H+ 5-(N-ethyl-N-isopropyl)-amiloride (EIPA) 1µM (n=9) y del inhibidor de la corriente tardía de Na+ ranolazina 5µM (n=9) / Canto Serrano, ID. (2015). Estudio de las modificaciones farmacológicas de los efectos electrofisiológicos producidos por el estiramiento local miocárdico a partir de técnicas dinámicas de cartografía eléctrica, en un modelo experimental de corazón aislado de conejo [Tesis doctoral no publicada]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/48544 / TESIS
47

Acurácia do gravador de eventos do marcapasso cardíaco artificial versus Holter na detecção de arritmias ventriculares sintomáticas e assintomáticas / Accuracy of the artificial pacemakers monitoring system versus 72h Holter in the detection of symptomatic and asymptomatic ventricular arrhythmias

Sampaio, Stela Maria Vitorino 30 September 2015 (has links)
O sistema Holter é considerado padrão ouro para detecção de arritmias cardíacas, possibilitando o seu diagnóstico e sua relação com os sintomas do paciente. As novas gerações de marcapassos (MP) detectam e registram eletrogramas intracavitários e poderiam dispensar o Holter no seguimento dos pacientes. Os diferentes MP dispõem de algoritmos de detecção de arritmias ventriculares (AV) que variam de acordo com o modelo e sua correlação diagnóstica com Holter foi pouco estudada. O objetivo desse estudo foi avaliar 1. a correlação entre o monitor de eventos dos MP e do Holter na detecção de AV e 2. a concordância das AV detectadas nos dois sistemas. Foram estudados129 pacientes portadores de MP com função de detecção de arritmias, com idade média de 68,6+19.1 anos (entre 19 e 94), 54,8% do sexo feminino. Os pacientes foram submetidos à monitorização com Holter por 72 horas. Assim que o sistema foi ligado, os contadores de eventos dos marcapassos foram reiniciados e os relógios sincronizados, para que ambos os sistemas detectassem os eventos simultaneamente. Os MP foram programados para detecção de eventos com o menor valor de frequência ventricular (FV) e o menor número de batimentos sequenciais (BT) possíveis. Depois de 72 horas, os sistemas Holter foram retirados e os registros analisados, assim como os registros simultâneos dos gravadores dos MP. Foram qualificados como eventos arrítmicos no Holter e MP, respectivamente: EV isoladas e \"PVC\"; extra-sístoles em pares e \"couplets\"; TVNS (> 3BT) e \"triplets\"(3BT), \"runs\"(3 a 8 ou > 8 BT) e \"HVR\" (3 ou 4 BT). As correlações de Spearman foram utilizadas para avaliar se o marcapasso acompanha a detecção dos parâmetros do Holter. Os coeficientes de correlação intraclasse e os respectivos intervalos com 95% de confiança, calculados para avaliar a concordâncias entre os parâmetros equivalentes do marcapasso e do Holter. Foram calculados os coeficientes Kappa para avaliar a concordância na detecção de > 10 \"PVC\"/h com > 10 EV/h. Resultados: Os monitores dos marcapassos subestimaram o Holter. Os registros de \"PVC\", \"triplet\" e \"HVR\" por TVNS apresentaram correlações positivas em relação aos parâmetros do Holter, sendo a mais alta aquela entre \"PVC\" e EV (r=0,501). Porém, a concordância entre os tipos de arritmias detectadas foi baixa (CCI < 0,5), exceção feita à concordância de \"triplet\" com TVNS de três batimentos (CCI=0.984). A concordância na detecção de mais de 10 PVC/h e mais de 10 EV/h foi moderada (kappa= 0,483), embora para os MP da Medtronic, o coeficiente de concordância foi alto (kappa=0.877). Para os MP com algoritmo de detecção de sequências de três batimentos com FV menor que 140bpm ( < 140/3), a correlação entre HVR e TVNS foi expressiva (r = 1), sendo a concordância entre esses parâmetros também bastante alta (CCI = 0,800). Conclusões: A correlação e a concordância na detecção de AV registradas nos MP e no Holter foram inconsistentes. Padronização dos algoritmos de detecção de AV, semelhantes os do sistema Holter, é necessária para que os pacientes portadores de dispositivos implantáveis possam se beneficiar dessa função para seguimento clínico e estratificação de risco / The Holter monitoring is considered the gold standard method for detection of cardiac arrhythmias, enabling its diagnosis and its correlation with the patient\'s symptoms. New generations of artificial pacemakers can detect and record intracavitary electrograms and, theoretically, could discard the Holter during the follow-up of the patients. Pacemakers have different ventricular arrhythmias (VA) detection algorithms, varying according to the model. Their diagnosis capacity comparing to Holter monitoring has been poorly studied. The aim of this study was to evaluate 1. the correlation between the event monitor of the pacemaker and the Holter in VA detection and 2. the agreement between the VA detected in both systems. We studied 129 patients with implanted pacemakers, which had arrhythmia detection function, mean age of 68.6 + 19.1 years (19 to 94), 54.8% female. The patients underwent Holter monitoring for 72 hours. Once the system was connected, event counters of pacemakers were reset and the clocks synchronized, so that both systems could detect the arrhythmic events simultaneously. The pacemakers were programmed to detect events with the lowest ventricular rate and lowest number of sequential beats allowed for each model. After 72 hours, Holter systems were removed and the records analyzed, as well as the simultaneous records of the pacemakers. Were considered as arrhythmic events: PVC isolated (in the pacemaker described as \"PVC\"); premature beats in pairs (pacemaker described as \"couplets\"); NSVT (pacemaker described as \"triplets\"- 3beats, \"runs\"- 4 to 8 or > 8 beats and \"HVR\"- 3 to 4 beats). Spearman rank correlations were used to assess whether the pacemaker and Holter identified the same parameters. The intraclass correlation coefficients and the respective intervals with 95% confidence were calculated to evaluate the concordance between the equivalent parameters of the pacemaker and Holter. Kappa coefficients were calculated to assess the agreement in the detection of > 10 PVC/h by the pacemakers and by the Holter. Results: The pacemakers underestimated the arrhythmias detection of Holter. Records of \"PVC\", \"triplet\" and \"HVR\" by NSVT showed positive correlations with the Holter parameters, and the highest one was among \"PVC\" and EV (r = 0.501). The agreement between the types of arrhythmias detected was quite low (CCI < 0.5), except for \"triplet\" detected by pacemakers and three beats NSVT by Holter (ICC = 0.984). The correlation detection for more than 10 PVC /h was moderate (kappa = 0.483), except for Medtronic pacemakers (kappa=0.877). When the pacemaker was programmed to detect sequences of three beats with heart rate lower than 140bpm ( < 140/3), the correlation between HVR and NSVT was perfect (r = 1) and the agreement between these parameters was also quite high (ICC = 0.800). Conclusions: The correlation and agreement between pacemakers and Holter monitoring in the detection of VA were not consistent. A standardization of the pacemakers\' detection algorithms is necessary before using this function for clinical follow-up and risk stratification of the patients
48

Estudo comparativo do uso de anestésicos locais com ou sem vasoconstritor em pacientes com arritmias cardíacas durante tratamento odontológico de rotina / Comparative study using local anesthesic solution with and without vasoconstrictor in patients wiht cardiac arrhytmias during routine dental treatment

Cáceres, Maria Teresa Fernández 23 February 2007 (has links)
A utilização de anestésicos locais associados a substâncias vasoconstritoras para tratamento odontológico de rotina de pacientes cardiopatas ainda é controversa, devido ao risco de efeitos cardiovasculares adversos. Objetivo: avaliar possíveis alterações hemodinâmicas relacionadas ao uso de anestésico local com vasoconstritor não adrenérgico em pacientes portadores de arritmias cardíacas comparando ao uso de anestésico sem vasoconstritor. Métodos: Estudo prospectivo randomizado, avaliou 33 pacientes com sorologia positiva para Doença de Chagas e 32 pacientes com Doença Arterial Coronariana, portadores de arritmia ventricular complexa ao Holter (>10 EV/h e TVNS), 21 do sexo feminino; idade 54,73 ± 7,94 anos, submetidos a tratamento odontológico de rotina com anestesia pterigomandibular, divididos em dois grupos: Grupo I -utilizando-se prilocaína a 3% com felipressina 0,03 UI/ml e Grupo II -lidocaína 2% sem vasoconstritor. Foram avaliados o número e complexidade de extrassístoles, a freqüência cardíaca e a pressão arterial sistêmica dos pacientes no dia anterior, uma hora antes, durante e uma hora após o procedimento odontológico. Resultados: Não foram observadas alterações hemodinâmicas relacionadas ao anestésico utilizado, nem diferença estatisticamente significativa entre os grupos. Conclusão: Prilocaína a 3% com felipressina 0,03 UI/ml pode ser utilizada com segurança em pacientes chagásicos e coronarianos com arritmia ventricular complexa. / The use of a local anesthetic solution with a vasoconstrictor agent for routine dental treatment in patients with cardiovascular disease is still controversial. Objetive: to evaluate the possible hemodynamics effects related to the use of a local anesthetic solution associated with a non-adrenergic vasoconstrictor agent, comparatively to another local anesthetic solution without a vasoconstrictor agent, in patients with cardiac arrhythmia. Methods: Prospective, randomized study, evaluated 33 patients with Chagas´s Cardiomyopathy and 32 with Coronary Artery Disease, 21 female; mean age 54,73 ± 7,94 of years old and complex ventricular arrhythmia detected by the 24 hours Holter monitoring. The patients underwent a routine dental treatment with pterygomandibular anesthesia, divided into two groups: Group I - received local anesthesia with 3% prilocaine associated with felypressin 0,03UI/ml and Group II - received 2% lidocaine without vasoconstrictor. Heart rate, number and complexity of premature ventricular beats and systemic blood pressure were monitored the day before, one hour before, during and one hour after dental treatment. Results: There were no changes in the homodynamic parameters related to the anesthetic solution and no significant differences were observed between the two groups. Conclusion: These findings suggest that 3% prilocaine with felypressin 0,03 UI/ml can be safely used in patients with complex ventricular arrhythmia associated with Chagas´s and coronary artery desease.
49

Relação entre apnéia do sono, isquemia miocárdica, variabilidade da freqüência cardíaca e arritmias em portadores de doença arterial coronária / Relation between sleep apnea, myocardial ischemia, heart rate variability and arrhythmias in patients with coronary artery disease

Araújo, Cristiana Marques de 02 May 2007 (has links)
Introdução: É comum a associação entre apnéia do sono e a doença arterial coronária (DAC), devido a fatores predisponentes comuns como sexo masculino e obesidade. Entretanto, ainda não existe uma definição objetiva da relação entre apnéia e DAC. Objetivo: Avaliar se os episódios de isquemia miocárdica, a variabilidade da freqüência cardíaca (VFC) e as arritmias cardíacas de portadores de DAC sofrem alteração na presença da apnéia do sono. Métodos: Cinqüenta e três pacientes portadores de DAC foram submetidos à monitorização eletrocardiográfica ambulatorial de 48 horas e ao estudo do sono na primeira noite da monitorização. Os pacientes foram divididos de acordo com o índice de apnéia e hipopnéia (IAH) em: grupo Controle (IAH<=15) e grupo Apnéia (IAH>15). Os grupos foram comparados quanto à isquemia miocárdica, VFC e arritmias cardíacas ocorridas no período da vigília e do sono. Uma subanálise apenas com pacientes portadores de apnéia grave (IAH>30 - grupo Ap-Grave) foi realizada e comparada ao grupo Controle. A análise estatística foi realizada utilizando-se o teste de Mann-Whitney, teste de Fisher e teste T de student. Resultados: Não foram observadas diferenças nas características clínicas básicas entre os grupos, exceto pelos níveis de pressão arterial mais elevada no grupo Ap-Grave (p<0,05). Nenhum dos pacientes despertou por angina noturna; 75% foram submetidos a cateterismo cardíaco, sem diferença quanto à gravidade da DAC e aos valores da fração de ejeção. Foi registrada isquemia em 39 (73,58%) pacientes, com carga isquêmica de 2892,26 minutos na vigília e 1186 no sono. Na vigília, foi menor a duração dos episódios isquêmicos no grupo Ap- Grave (p<0,05); no período do sono não houve diferença entre os grupos. Não houve diferença nas medidas da VFC e arritmias entre os grupos. Não foram registradas pausas >2 segundos, fibrilação ou flutter atrial, ou qualquer tipo de bloqueio atrioventricular. Conclusão: A apnéia do sono não apresentou relação direta com isquemia miocárdica, variabilidade da freqüência cardíaca e arritmias cardíacas em pacientes portadores de DAC. / Introduction: It is common to associate obstructive sleep apnea (OSA) with coronary artery disease (CAD) given the common predisposing factors; however, there are still controversies on the influence of OSA in the progression of CAD. Objective: To assess if OSA causes any changes in myocardial ischemia episodes, heart rate variability (HRV) and cardiac arrhythmias in patients with CAD. Methods: Fifty-three people with CAD were submitted to ambulatory electrocardiographic monitoring and to polysomnography) simultaneously and divided according to the apnea-hypopnea index (AHI) into two groups: Control (AHI<=15) and Apnea (AHI>15). A sub analysis including only people with severe apnea (AHI>30) was done and compared with the control group. Results: Differences in the basic clinical characteristics between the groups were not found, except for higher blood pressure levels in the Severe Apnea Group (p<0.05). None of the patients woke up because of nocturnal angina. The groups did not differ in relation to the extension of coronary artery disease and ejection fraction values. Myocardial ischemia was recorded in 39 (73.58%) patients. The total ischemic burden was 2892.26 minutes while awake and 1186 minutes while asleep; the groups did not differ during sleep. There was also no significant difference in HRV and arrhythmia measurements between the groups. Pauses >2 seconds, fibrillation or atrial flutter or any type of atrioventricular blocks were not registered. Conclusion: OSA did not present a direct relationship with myocardial ischemia, heart rate variability and arrhythmias in patients with CAD.
50

Eletrocardiografia em equinos do regimento de polícia montada do estado do Espírito Santo

Lima, Marcelo Borjaille 17 August 2011 (has links)
Made available in DSpace on 2016-12-23T13:53:35Z (GMT). No. of bitstreams: 1 Marcelo Borjaille Lima.pdf: 798361 bytes, checksum: 390f0f5564bc81315e64b0626f3a736b (MD5) Previous issue date: 2011-08-17 / The eletrocardiographic test has been used for diagnosis of cardiac arrhythmias and heart disease in horses, as well as performance evaluation and early diagnosis of worsening of athletic performance of various modalities. The activity of mounted police requires that animals are trained for long hours at walk and trotting, thus monitoring of these animals for underlying cardiac diseases that may affect their performance is of great value. In this study from 78 animals of the regiment of mounted Military Police Patrol of Espirito Santo State, Brazil, were divided into groups according to age and underwent electrocardiographic examination, followed by analyses of durations and amplitudes of the waves and QRS. There was statistical difference in T+ wave amplitude which was correlated to animals growth. These horses did not show any arrhythmias at rest, while the most common was the sinus rhythm / O exame eletrocardiográfico tem sido utilizado para o diagnóstico de arritmias e doenças cardíacas em equinos, bem como na avaliação do desempenho atlética e diagnóstico precoce da queda de performance em diversas modalidades. A atividade de policiamento montado requer que os animais estejam aptos a trabalhar ao passo e trote durante horas para atuação da sua função. Portanto, o monitoramento destes animais quanto a doenças cardíacas é importante. Desta forma, 78 animais do regimento de polícia montada do Estado do Espírito Santo, Brasil foram separados em grupos de acordo com a idade e submetidos ao exame eletrocardiográfico para analise das durações e amplitudes de ondas e complexos do traçado. Foi observada diferença estatística somente na amplitude da onda T+ relacionadas com o passar da idade dos animais. Os equinos, em repouso, não apresentam arritmias, sendo o ritmo sinusal o mais comum

Page generated in 0.0419 seconds