• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 102
  • 1
  • Tagged with
  • 103
  • 103
  • 90
  • 87
  • 34
  • 32
  • 28
  • 23
  • 21
  • 15
  • 12
  • 12
  • 10
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Sistemas de tecnologias colaborativas urbanas : os casos da rede Fab Lab Livre SP e do MobiLab

Bertholdo Neto, Emílio 08 February 2018 (has links)
Submitted by Giovanna Brasil (1154060@mackenzie.br) on 2018-04-26T20:22:12Z No. of bitstreams: 2 Emílio Bertholdo Neto.pdf: 5089675 bytes, checksum: 4b3addd9ca51bd7056e720ecea1edb62 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Paola Damato (repositorio@mackenzie.br) on 2018-05-04T14:36:16Z (GMT) No. of bitstreams: 2 Emílio Bertholdo Neto.pdf: 5089675 bytes, checksum: 4b3addd9ca51bd7056e720ecea1edb62 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2018-05-04T14:36:16Z (GMT). No. of bitstreams: 2 Emílio Bertholdo Neto.pdf: 5089675 bytes, checksum: 4b3addd9ca51bd7056e720ecea1edb62 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2018-02-08 / The work consists in a study about the concept of smart cities by emphasizing the processes of developing cooperative urban technology and inclusive city management represented by the main studied cases the MobiLab and Fab Lab Livre SP Network. The choices of those two research objects relies on the will to understand the emergency of theses public policies that enables the developing of intelligence allowing a popular network to be held responsible to encourage the involvement during the current stage. The research deployed quantitative and qualitative methods as case study methodology, exploratory and semi-structured interview, participant observation and database analysis. In order to gather enough data to support the analysis the research was structure through interviews with the users and other important players, semi structured questionnaire with MobiLab Users and data analysis from management system database from Fab Lab Livre SP. Those data were the groundwork for the statistics that shaped the appraisal to the cases studied. / O presente trabalho consiste na análise do conceito de cidade inteligente com foco em processos de produção de tecnologias urbanas colaborativas e gestão participativa da cidade tendo como principais modelos o MobiLab e a Rede de Fab Lab Livre SP. A escolha dos dois objetos visou a compreender a emergência políticas públicas tendo as redes como agenciador das relações e das etapas de desenvolvimento. A pesquisa utilizou métodos quantitativos e qualitativos, como a metodologia de análise de estudo de caso, entrevistas exploratórias, semiestruturadas, observação participante e análise de banco de dados. Para isso, recorreuse a entrevistas com usuários e demais interlocutores, questionário semi-estruturado para o público do MobiLab e análise das bases de dados do sistema gestor do Fab Lab Livre SP. Os dados coletados, embasaram as análises estatísticas que compõem a pesquisa e deram corpo a avaliação dos casos analisados.
52

Proposta de metodologia para melhora do posicionamento obtido através de receptores GPS de baixo custo. / Proposal of a methodology for improving low cost GPS receivers positioning.

Lima, Erly Caldas de 08 May 2018 (has links)
O desenvolvimento técnico da eletrônica, a contínua redução do tamanho dos receptores GNSS, associada à diminuição do consumo de energia, transformaram estes produtos em alguns circuitos integrados ou apenas pequenos chips do tamanho de um botão de uma camisa. Desta forma pode-se promover a sua integração com inúmeros dispositivos eletrônicos. A associação com os telefones celulares foi principalmente impulsionada pelo mandato de aprimoramento dos serviços 911 (E911) da Federal Communications Commission (FCC) nos Estados Unidos, exigindo que todas as operadoras de telefonia móvel daquele país fornecessem a localização com boa precisão das chamadas de emergência. Esta necessidade estimulou a produção dos chips em larga escala e, portanto, a diminuição do custo e a sua popularização. Desta maneira quase que em sua totalidade, os telefones celulares são hoje fabricados com receptores GPS, o que torna estes dispositivos uma das fontes mais baratas de se obter o Geoposicionamento. Acontece que existe uma lacuna na literatura quanto à precisão e a exatidão das coordenadas fornecidas por estes equipamentos. O presente trabalho visa, através de testes estatísticos e da comparação com outros receptores GPS e métodos, quantificar estes valores e propor uma metodologia para melhorar tal posicionamento. Para conseguir o objetivo, a estrutura do Sistema Operacional do telefone foi modificada de tal modo que fosse possível o acesso às observáveis do chipset do GPS embarcado e convertidos para o padrão RINEX de arquivamento de dados brutos. Os testes foram executados com o equipamento original e com o equipamento modificado com a instalação de uma antena externa e mostraram que com a utilização da medida de fase da portadora o equipamento pode fornecer o posicionamento com uma precisão média de 0,069m, com o desvio padrão de 0,047m e erro planimétrico de posicionamento máximo de 0,218m e mínimo de 0,004m. / The technical development of electronics, the continuous reduction in the size of GNSS receptors, allied with the energy consumption decrease, transformed these products into some integrated circuits or in small Chips as small as size of a button of a shirt. In this way one can promote its integration with countless electronic devices. The association with cell phones was mainly driven by the mandate to enhance services 911 (E911) of the Federal Communications Commission (FCC) in the United States, requiring that all mobile carriers of that country provide all the emergency calls location with good accuracy. So as to fulfill this necessity, the production of Chips in a large scale has been stimulated and therefore the decrease in cost and its popularity. In this way almost in its entirety, cell phones are now manufactured with GPS receivers, which makes these devices one of the cheapest sources to obtain the geopositioning. It turns out that there is a gap in the literature about how precise and accurate the coordinates provided by these equipments can be. This thesis aims through statistical tests and comparison with other GPS receivers and methods, quantify these values and propose a methodology to improve such positioning. To achieve the objective, the structure of the phone\'s operating system was modified in such a way that it was possible to access the embedded GPS Chipset observables and then converted into the RINEX standard raw data file. The tests were carried out with the original equipment and with the modified ones, with an external antenna installation which showed that using the phase measure of the carrier, the equipment can provide a positioning with an average accuracy of 0, 069m, with a default deviation of 0, 047m and a maximum planimetric positioning error of 0, 218m and a minimum of 0, 004m.
53

Oxidação cíclica em alta temperatura de ligas ferrosas fundidas de baixo custo / Cyclic oxidation of low cost iron-based cast alloys in high temperature

Malafaia, Artur Mariano de Sousa 25 October 2013 (has links)
A oxidação cíclica é um fenômeno que pode trazer problemas a diversas indústrias e, apesar de estudada em grande medida para materiais de alto desempenho, como superligas, pesquisas em materiais menos nobres são incipientes. Essa tese teve como objetivo investigar as propriedades de oxidação cíclica de materiais ferrosos de baixo custo e compará-las com as do aço inoxidável fundido ASTM A 297 grau HH modificado. A motivação surgiu de uma análise de falha de componente feito com aço HH e da possibilidade de pesquisar materiais com melhor relação custo-benefício em aplicações onde a principal solicitação seja a de resistência à oxidação cíclica. Seis ligas ferrosas com teores de cromo e níquel menores que o do aço HH, ou sem esses elementos, compuseram o estudo. Nestas ligas, os elementos silício e alumínio (1 liga) foram utilizados como alternativa para resistir à oxidação. As composições das ligas (% em peso) foram aproximadamente Fe-15Al-1,1C, Fe-14,5Si-4Cr-0,75C, Fe-5Si-5Cr-V-C, Fe-5Si-5Cr-4Ni-Nb-C, Fe-17Mn-5Si-10Cr-4Ni-V-C e Fe-12Mn-5Si-10Cr-4Ni-Nb-C, além do aço HH modificado (HH-mod). Foram realizados ensaios de oxidação cíclica nas temperaturas de 800, 900 e 1000 ºC e ensaios de dureza, tração e impacto. As ligas mostraram fragilidade, com exceção das ligas com alto teor de manganês que superaram o aço HH-mod em tenacidade. Em oxidação cíclica, as ligas apresentaram boa resistência, com taxas de variação de massa pequenas ou moderadas, e quando houve destacamento, este foi menor que o apresentado pelo aço HH-mod. Camadas oxidadas foram caracterizadas por técnicas de microscopia eletrônica de varredura (MEV), espectroscopia por dispersão de energia de raios-X (EDX) e difração de raios-X (DRX). Foi possível verificar a formação de óxidos protetores de Si, Cr ou Al, mas também de Fe, Cu e principalmente Mn. Por fim, a determinação das cinéticas de ganho de massa e destacamento mostrou que apesar de algumas ligas apresentarem kp maiores que os do aço HH-mod, todas sofreram menores destacamentos, o que ocorreu para o aço HH-mod nas três temperaturas, devido à diferença entre coeficientes de expansão térmica da matriz austenítica e dos óxidos. Dentre as demais ligas, Fe-15Al-1,1C e Fe-5Si-5Cr-4Ni-Nb-C não sofreram destacamentos e apresentaram baixo ganho de massa, devido às finas camadas de óxido e assim apresentando os melhores resultados. / The cyclic oxidation phenomenon can cause problems to several industries. Although studied in high performance materials, as superalloys, researches on less noble materials are incipient. The aim of this thesis was investigate the cyclic oxidation properties of low cost iron-based alloys and compare them with a cast stainless steel ASTM A 297 HH modified grade. The motivation was a failure analysis on a component made of HH and the possibility of research materials with a better cost-benefit ratio for applications where the main solicitation is the cyclic oxidation resistance. Six alloys with less chromium and nickel amount than HH steel, or without these elements, constituted the study. In these alloys, silicon and aluminum (1 alloy) were used to improve the oxidation resistance. The alloy compositions (weight %) were nearly Fe-15Al-1,1C, Fe-14,5Si-4Cr-0,75C, Fe-5Si-5Cr-V-C, Fe-5Si-5Cr-4Ni-Nb-C, Fe-17Mn-5Si-10Cr-4Ni-V-C and Fe-12Mn-5Si-10Cr-4Ni-Nb-C, and the HH steel modified (HH-mod). Cyclic oxidation tests were performed at 800, 900 and 1000 ºC and also hardness, impact and tensile tests. The alloys studied presented brittleness, and only the high Mn alloys had better mechanical properties than HH-mod steel. The alloys presented good results on cyclic oxidation, with low or moderate oxidation rates and when suffering spallation, it was less than HH-mod steel. Oxidized scales were characterized by scanning electron microscope (SEM), energy dispersive spectroscopy (EDS) and X-Ray diffraction (XRD). The formation of protective oxide of Si, Cr or Al was noticed, but also Fe, Cu and Mn oxides were found. Finally, the mass gain and spallation kinetics was determined, and spite the fact of some alloys having higher kp values than HH-mod, no alloys suffered more spallation than HH steel. The austenitic matrix was considered the responsible of this behavior in all temperatures, due to the high thermal expansion coefficient compared with oxides. The better results were found to Fe-15Al-1,1C and Fe-5Si-5Cr-4Ni-Nb-C alloy, with low mass gain and without spalling, on account of the thin oxide scales formed.
54

Funcionalização de celulose para ensaios bioanalíticos em dispositivos microfluídicos baseados em papel (μPADs) / Cellulose modification for bioanalytical assays on paper-based microfluidic devices (µPADs)

Morbioli, Giorgio Gianini 09 June 2015 (has links)
A funcionalização da matriz celulósica é um ponto essencial para o aprimoramento dos dispositivos microfluídicos baseados em papel (µPADs). Ela permite minimizar o preparo de amostras e a interferência do usuário, principais fontes de erro no processo analítico. A oxidação da celulose durante uma hora com m-periodato de sódio e a imobilização química de enzimas a partir da formação de bases de Schiff (iminas), via a adição direta da enzima ao substrato oxidado sem a necessidade de outras etapas, é um processo rápido e de baixo custo, apresentando grande potencialidade de aplicação nos dispositivos microfluídicos em papel. A enzima glicose oxidase imobilizada na celulose, com a adição do estabilizante trealose, apresentou elevada atividade catalítica - de 31,9 ± 5,5 mmol L-1 para a enzima não imobilizada a 14,8 ± 2,0 mmol L-1 para a enzima imobilizada e com o estabilizante - além de apresentar maior homogeneidade de sinal, condições desejáveis em testes rápidos em papel. A confecção de dispositivos em papel via impressão em cera alia rapidez e baixo custo de produção, e o arranjo em camadas para originar dispositivos tridimensionais (3D) permite ampliar as funcionalidades dos dispositivos em duas dimensões, tal como o tratamento individualizado de camadas e o armazenamento de reagentes no próprio dispositivo. O método da adição de padrão para obtenção de curvas analíticas no próprio microchip em papel surge como alternativa às curvas analíticas externas, minimizando a manipulação e o preparo de amostras. O uso do ácido 2,2’-azino-bis (3-etilbenzotiazolina-6-sulfônico) - ABTS como indicador redox para as reações enzimáticas e o método de adição de padrão nos µPADs apresentou boa correlação com um modelo de crescimento e saturação de Michaelis-Menten (r2 = 0,8723) na faixa de 0 a 10 mmol L-1, e a utilização da faixa linear para quantificação de glicose (0 a 3 mmol L-1) apresentou grande correlação linear com a concentração estimada pelas curvas de adição de padrão (r2 = 0,959), demonstrando a potencialidade do método. A união da tecnologia desses dispositivos em papel com a de um software automatizado de reconhecimento de imagens (PAlizer) torna instantânea a obtenção de resultados, eliminando-se a necessidade de intervenção humana no processo, tornando os testes em papel mais robustos, reprodutíveis e rápidos. Com o contínuo aperfeiçoamento das funcionalidades e potencialidades dos dispositivos microfluídicos em papel espera-se que os testes diagnósticos de baixo custo atinjam àqueles que deles necessitam, contribuindo para a saúde da população. / Functionalization of a cellulosic matrix is essential for the success of the paper-based microfluidic analytical devices (µPADs). It allows minimization of sample preparation and user interference, both being major sources of errors in the analytical process. Cellulose oxidation with sodium m-periodate during one hour and the direct chemical immobilization of enzymes on it by Schiff-base (imines) formation, which is made by direct insertion of the enzyme on the oxidized substrate without subsequent steps, is a fast and low cost process of immobilization, presenting great potential of application in paper-based microfluidic analytical devices. The glucose oxidase enzyme immobilized on cellulose, with the addition of trehalose stabilizer presented enhanced catalytic activity - from 31.9 ± 5.5 mmol L-1 for the non-immobilized enzyme to 14.8 ± 2.0 mmol L-1 for the immobilized enzyme with the stabilizing agent - also presenting greater signal homogeneity, which are ideal characteristics in a paper-based rapid test. Wax printing is a simple, inexpensive and fast method by which micro-devices can be fabricated. Additionally, the stacking of layers originating tridimensional devices (3D) allow for the improvement of functionalities of 2-dimensional ones, such as individualized layer treatment and reagent storage at different layers in the same device. Standard addition to analytical curves in paper-based microchips is an alternative to external analytical curves, minimizing handling/sample preparation. The use of 2,2\'-azino-bis(3-ethylbenzothiazoline-6-sulphonic acid - ABTS redox indicator with the enzymatic reactions and the standard addition method in µPADs presented a good correlation in a growth and saturation Michaelis-Menten model (r2 = 0.8723), in the range of 0 to 10 mmol L-1, and the usage of the linear range to the glucose quantification (0 to 3 mmol L-1) presented a high linear correlation with the estimated concentration from the standard addition curves (r2 = 0.959), showing the potentiality of the method. The coupling of such paper-based devices to automated image analysis software, such as \'PAlizer\', turns the data acquisition process instantaneous, eliminating the need of human intervention during the process, making it more robust, reproducible and rapid. Expectations lie in improving the devices functions and potential so that these low-cost diagnostic devices can one day reach those who need them, contributing significantly to public health.
55

Plataforma web de atividades terapêuticas: desenvolvimento e aplicação / Web platform of therapeutic activies: development and application

Simões, Janaina de Souza 15 December 2017 (has links)
INTRODUÇÃO: O emprego de novas tecnologias na reabilitação de linguagem pode auxiliar amplamente o processo terapêutico mediante treino intensivo. Para isso, no entanto, é necessário que essas ferramentas atendam às demandas desses pacientes, e que o terapeuta seja protagonista no desenvolvimento dessas tecnologias. Essas ferramentas precisam ainda ser analisadas por meio de pesquisas científicas que avaliem sua efetividade no tratamento fonoaudiológico. OBJETIVOS: Desenvolver uma plataforma on-line para reabilitação de pacientes afásicos e avaliar sua eficácia em dois experimentos. MÉTODOS: Essa pesquisa foi dividida em três estudos: Estudo 1) criação da plataforma com emprego do modelo de desenvolvimento ágil e com uso de software livre, e aplicação das normas de qualidade ISO 25010. Estudo 2) estudo prospectivo, longitudinal e intervencionista, com a finalidade de prover treino de aprendizado de palavras, para avaliar as opiniões de 12 pessoas idosas cognitivamente sadias sobre o uso da plataforma. Os participantes foram divididos em três grupos: grupo controle (GC); grupo experimento escrita (GEE); grupo experimento repetição (GER). O treino foi conduzido na plataforma e foi composto por atividades de treino com emprego de 60 pseudopalavras, associadas a figuras. O estudo teve duração de um mês para cada participante, sendo composto por três etapas: 1) Pré-treino (1 dia); 2) Treino (5 dias) e 3) Pós-treino (3 dias). As etapas 1 e 3 foram comuns para todos os participantes. Na etapa 1, os participantes realizaram duas atividades a plataforma com o propósito de apresentar a plataforma e os estímulos usados nas outras etapas do estudo. Na etapa 2, os GEE e GER realizaram o treino de pseudopalavras, enquanto o GC realizou atividade de jogos. A etapa 3 foi dividida em três avaliações: após os cinco dias de treino; uma semana após a primeira avaliação e 1 mês depois do início do treino. A análise estatística avaliou a acurácia (número de acertos); efeitos de idade, escolaridade, intensidade e modalidade do treino; e o impacto de propriedades dos estímulos. O Estudo 3 apresenta o relato de caso de uma paciente com afasia de Wernicke grave, que usou a plataforma intensamente ao longo de 18 meses de terapia de linguagem. RESULTADOS: Estudo 1) Criação da plataforma com elaboração de 114 atividades terapêuticas, com exportação de dados para análise estatística e adequação às normas de qualidade ISO 25010. Estudo 2) Os participantes dos grupos GEE e GER apresentaram desempenho significativamente superior ao do GC em todas as etapas do pós-treino. Todos os participantes apresentaram opiniões favoráveis sobre a plataforma. Estudo 3) A paciente apresentou melhora significativa em habilidades linguísticas, com uso de 58 atividades da plataforma, totalizando 280 horas de treino com a ferramenta. CONCLUSÕES: A plataforma mostrou-se eficiente para atender às necessidades de pessoas idosas cognitivamente sadias e na reabilitação de linguagem / INTRODUCTION: The application of new technologies in language rehabilitation has the potential to improve therapies through intensive training. But, to that end, it is important that these tools meet the needs of patients and that the therapist becomes a main player during the development of these technologies. These tools also need to be evaluated by means of scientific research that evaluate their effectiveness on the speech and language pathology treatment. OBJECTIVE: To develop an online platform for the rehabilitation of aphasic patients, and to evaluate its effectiveness in two experiments. METHODS: This research was divided into three studies: Study 1) creation of the platform using the agile development model and free software, and application of ISO 25010 quality standards. Study 2) a prospective, longitudinal and interventional study with the purpose of providing training in word learning, in order to evaluate the opinions of 12 cognitively healthy elderly people on the use of the platform. Participants were divided into three groups: control group (CG), writing experiment group (WEG), and repetition experiment group (REG). The training was conducted on the platform and was composed of training activities with the employment of 60 pseudowords, associated with pictures. The study had a duration of one month for each participant, and was composed of three stages: 1) Pre-training (1 day), 2) Training (5 days), and 3) Post-training (3 days). Stages 1 and 3 were common to all participants. In the stage 1, the participants performed two activities in platform in order to present the platform and the stimulus used in the other stages. In stage 2, the WEG and REG performed pseudoword training; and the CG performed gaming activity. Stage 3 was divided into three evaluations: a) after five days of training, b) one week after the first evaluation, and one month after the beginning of training. The statistical analysis evaluated the accuracy (number of hits); effects of age, schooling, intensity, and training modality; and the impact of stimulus properties. Study 3) presented the case report of a patient with severe Wernicke\'s aphasia who used intensively the platform over 18 months of language therapy. RESULTS: Study 1) Creation of the platform with elaboration of 114 therapeutic activities, with export of data for statistical analysis and adaptation to ISO 25010 quality standards. Study 2) Participants in the WEG and REG groups presented performance significantly superior to the CG in all post-training steps. All participants presented favorable opinions on the platform. Study 3) The patient presented significant improvement in language skills with the use of 58 platform activities, totaling 280 hours of training with the tool. CONCLUSIONS: The platform proved to be an efficient tool in meeting the needs of cognitively healthy older people and in language rehabilitation
56

Proxy IP de baixo custo e m?ltiplos sensores para cidades inteligentes / Proxy IP low cost and multiple sensors to smart cities

Machado, Leandro Filiagi 18 December 2015 (has links)
Made available in DSpace on 2016-04-04T18:31:46Z (GMT). No. of bitstreams: 1 Leandro Filiagi Machado.pdf: 5882687 bytes, checksum: be6f1f6830e339317c23060e0e5453e3 (MD5) Previous issue date: 2015-12-18 / With the advancement of Urban Intelligence and Smart Cities, the importance of remote monitoring and data collection increased. Regarding the monitoring data, the IP Proxy is an important platform for the realization of interconnection between the sensors and the Internet. In recent literature, several gateway architectures for network sensors have been proposed to integrate Wireless Sensor Network (WSN) and Internet. Most WSN gateways implementations retrieve sensor data and display the results to customers via the web. The disadvantage of these solutions is that they use specific protocols to connect the sensors, thereby prohibiting direct interaction between clients and sensor nodes. Optionally, the adoption of sensors for SNMP management has the potential to reduce the complexity of the gateway. For this reason, this paper presents the design and implementation of an open platform and low cost with the use and modification of a non-commercial wireless router with serial connection to communicate with the sensors, which are connected to an Arduino Nano microcontroller. The results showed that applications of the IP Proxy can successfully connect multiple sensors and the Internet, where data can be transmitted all over the world via the Ethernet or WLAN. / Com o avan?o da intelig?ncia Urbana e as Cidades Inteligentes, a import?ncia do monitoramento remoto e coleta de dados aumentou. Em rela??o ao monitoramento de dados, o ProxyIP ? umaplataforma importante para a realiza??oda interconex?o entre os sensores e a Internet. Na literatura recente, v?rias arquiteturas de gateway para sensores de rede t?m sido propostas para integrar Rede de Sensores sem Fio (RSSF) e Internet. A maioria das implementa??es de gateways de RSSF recuperam dados de sensores e exibem os resultados para os clientes via web. A desvantagem dessas solu??es ? que eles usam protocolos espec?ficos para ligar os sensores, proibindo assim a intera??o direta entre clientes e n?s sensores. Como op??o, a ado??o do protocolo SNMP para gerenciamento de sensores tem o potencial para reduzir a complexidade do gateway. Por esta raz?o, este trabalho apresenta a concep??o e implementa??o de uma plataforma aberta e de baixo custo com o uso e modifica??o de um roteador sem fio comercial, com conex?o serial para se comunicar com os sensores, que s?o ligado a um microcontrolador Arduino Nano. Os resultados das aplica??es mostraram que o Proxy IP pode interligar com ?xito multiplos sensores e a Internet, onde os dados podem ser transmitidos em todo o mundo atrav?s da Ethernet ou WLAN.
57

Estudo comparativo entre o método USP de terapia por pressão negativa e o sistema V.A.C® no tratamento de feridas traumáticas / A low-cost negative pressure wound therapy versus a widely commercially available therapy for the treatment of complex traumatic injuries: a prospective, randomized, non-inferiority trial

Kamamoto, Fábio 01 February 2017 (has links)
A terapia de tratamento de feridas por pressão negativa (TPN) não é nova. Ela foi aprovada nos Estados Unidos da América em 1996 e, desde então, tem sido amplamente utilizada em uma grande variedade de ferimentos. Ela tem aplicação no tratamento de feridas agudas e crônicas, e trouxe conforto para pacientes, cuidadores e profissionais da área da Saúde. Uma das indicações desta terapia é no tratamento de feridas decorrentes de trauma. Ela pode ser utilizada como uma \"ponte\" entre o surgimento da lesão inicial e a cirurgia de fechamento definitivo da ferida, naqueles casos em que o fechamento primário não é possível. O grande obstáculo para democratização desse procedimento é o custo. Ele se mantém alto, principalmente nos pacientes que necessitam de um uso prolongado do método. Na tentativa de contornar esse problema, o Hospital Universitário da USP desenvolveu em 2007 uma TPN de baixo custo baseada em uma válvula estabilizadora de pressão (Curavac VX 200®, Ventrix Health Innovation, Brasil) conectada à fonte de vácuo da parede do hospital e a uma cobertura de ferida com gaze estéril selada por filme plástico adesivo. Este estudo comparou essa terapia de baixo custo (grupo USP) com a terapia padrão no Mercado (VAC system®, KCI, San Antonio - Texas) - Grupo VAC em um desenho prospectivo, randomizado, no formato de não inferioridade. Ou seja, o objetivo primário era verificar se o tempo necessário para a ferida estar apta para cirurgia de fechamento definitivo era equivalente nos dois métodos propostos. Foram estudadas, também, a velocidade de crescimento do tecido de granulação e as mudanças na área da ferida, além do custo de cada tratamento. Em relação ao tempo necessário para ferida estar apta para a cirurgia de retalho, o Grupo USP apresentou um resultado de 9,6±4,5 dias. O Grupo VAC apresentou 12,8±8,6 dias. A diferença não foi estatisticamente significante (p=0,379). Em relação ao aumento de tecido de granulação por dia de tratamento, os dois métodos apresentaram resultados semelhantes: USP= 5,79 ± 2,93% e VAC 5,06 ± 5,15% (p=0,408). Em relação à variação de área, os dois grupos apresentaram um aumento: USP 1,13 ±0,80% e VAC 1,12 ± 0,80% (p=0,934). Foi observada uma importante diferença entre os custos do tratamento. O tratamento no Grupo USP custou, em média, R$ 47,89; enquanto o tratamento no grupo VAC, R$ 2.757,40. Conclusão: A terapia USP de tratamento de feridas por pressão negativa não é inferior à terapia VAC system® no tratamento de feridas complexas de origem traumática / Negative Pressure Wound Therapy (NPWT) was approved by the FDA in 1996 and since then has become widely adopted for a broad range of wounds. NPWT has many indications, both acute and chronic, and has brought great comfort to patients, caregivers, doctors, and nurses. Some authors suggest that NPWT may be used in traumatic wounds when primary closure is not possible after or in between debridements as a bridge to definitive closure. The big real obstacle to this useful procedure is the cost, which remains expensive for prolonged indications, making it unaffordable where these dressings are needed. In 2007 the University of São Paulo developed a low-cost NPWT based in a pressure stabilizer device (Curavac VX 200®, Ventrix Health Innovation, Brazil) connected to the hospital wall-vacuum and a gauzed-sealed dressing. No randomised trial has compared USP Negative Pressure Wound Therapy with the commercial vacuum assisted closure device (VAC system®). Our choice of a non-inferiority trial was based on the expectation that the time necessary for the improvement of the wound bed for patients treated with the USP therapy was no worse than the improvement time for VAC System (primary outcome). The wound bed area variation and granulation tissue growth were also assessed as secondary outcomes. In relation to the time (measured in days) necessary for the wound bed to became ready for the flap surgery, the USP group presented 9,6 ± 4,5 days. The VAC group presented 12,8 ± 8,6 days. The difference was not statistical significant (p=0,379). In relation to granulation tissue increase the two methods of NPWT (USP and VAC) presented very similar results: USP= 5,79( ± 2,93) and VAC 5,06 ( ± 5,15) (p=0,408). Regarding to wound area the both groups presented an increase: USP 1,13 ± 0,80 and VAC 1,12( ± 0,80) p=0,934. We observed an important difference in relation to treatment costs. The USP group treatment cost is about 2% compared with VAC group. Mean Treatment Cost: USP= US$ 15,15; VAC= US$ 872,59. Conclusion: The USP Negative Pressure Wound Therapy was non-inferior to VAC System for the treatment of complex traumatic injuries
58

Construção e avaliação de equipamento de baixo custo para análise experimental do comportamento de sujeitos não-humanos / Manufacturing and evaluation of low cost apparatus for non-human research in experimental analysis of behavior.

Rossger, Nicolas Carsten 09 April 2015 (has links)
Equipamentos utilizados em pesquisas em Análise Experimental do Comportamento com sujeitos não humanos tiveram uma trajetória intrincada ao próprio estudo do comportamento. Um tipo de equipamento importante nessas pesquisas é a câmara de condicionamento operante. Diversos incrementos foram feitos nessas câmaras, com estes focados no aumento do controle de variáveis independentes e no registro mais preciso de variáveis dependentes. Uma característica de equipamentos atualmente disponíveis no mercado é o seu alto custo de aquisição e a necessidade do uso de software fechado utilizado pelos mesmos. Diante disso, apresenta-se a construção e avaliação de equipamentos não comerciais de baixo custo para pesquisas operantes. Foram construídas duas câmaras de condicionamento, uma para pombos e outra para ratos. Com o objetivo de avaliar o equipamento construído, submeteram-se dois pombos e dois ratos a esquemas de reforço de razão fixa (FR) e razão variável (VR), e dois pombos e dois ratos a esquemas de reforço de intervalo fixo (FI) e intervalo variável (VI). Replicou-se a maior parte dos aspectos da literatura de esquemas de reforço simples com o equipamento apresentado, o que indica sua adequação ao uso em pesquisas de condicionamento operante como uma alternativa viável de baixo custo / Apparatuses used non-human research in experimental analysis of behavior have had a parallel trajectory to the study of behavior itself. A type of apparatus used in behavioral studies is the operant conditioning chamber. Several improvements have been done to these chambers, focusing in the control of independent variables and more precise registry of dependent variables. A feature of apparatuses available in the market is their high acquisition costs and the need of usage of closed software. In light of this, it is shown the construction and evaluation of alternative low cost apparatuses for behavioral research. Two operant conditioning chambers were built, one for usage with pigeons and the other for the usage with rats. In order to evaluate the apparatus, two pigeons and two rats were submitted to fixed ratio (FR) and variable ratio (VR) schedules of reinforcement, while another two pigeons and two rats were submitted to fixed interval (FI) and variable interval (VI) schedules of reinforcement. The majority of features related to the responding under simple schedules of reinforcement were replicated using the presented apparatus, which indicates its adequacy for the usage in behavioral research as a low cost alternative
59

Descrição do padrão de desenvolvimento motor em lactentes com síndrome de Down pela avaliação dos movimentos generalizados / Description of motor development pattern by General Movements assessment in infants with Down syndrome

Herrero, Dafne 20 February 2017 (has links)
Introdução:Tão importante quanto saber \"o que\" está mudando no desenvolvimento motor, é \"como\" e \"quando\" ocorrem essas mudanças. A falta desses dados ainda não permite a descrição desse processo de forma linear e contínua em grupos com distúrbios de movimento, tais como recém-nascidos com síndromede Down. A memória pode ser um fator de diferenciação no caso de desempenho motor e a construção de aquisição da trajetória do movimento. Portanto, aintegraçãomotora-cognitiva,e a ativação mnemônica poderiamser observadas na apresentação de uma riqueza do repertório motor demovimentação espontânea dos lactentes. Objetivo geral:Avaliara qualidade da movimentação espontânea em lactentescom síndrome de Down. Objetivos específicos: a) descrever as características genéticas e ambientais sobreas características deste grupo delactentes e o atual processo deintervenção; b) analisar a aplicabilidade da avaliaçãoGeneral Movementsem lactentes até oscinco meses de vidaem paísesde baixae médiarenda e; c) avaliar a movimentação espontânea como facilitadora do vínculo mãe-bebê. Métodos:revisão e elaboração da temática,por busca em bases de dados científicos, para estruturar de forma factível a execução da avaliação e aplicação do questionário neste grupo de lactentes. Foi um estudo exploratório,com a avaliaçãopresencial e por gravações de vídeo, de 47 lactentes, menores de 5 mesescom síndrome de Down pela avaliação dos General Movements; além do preenchimento de um questionário cominformaçõestais como: o momento em que o diagnóstico foidito para os pais, o tempo de amamentação, o período que permaneceram na unidade de Cuidados Intensivos, se os pais estavamempregados e a idade dos pais. A avaliação foi feita na idade Fidgety(de 11 a 20 semanas após a idade do termo). Os locais de coleta dos dados foram: 24 lactentes doHospital Infantil Darcy Vargas e a Instituição APAE de São Paulo (o hospital pertence ao SUS -Sistema Único de Saúde),ambos representam locais de referência no atendimento de crianças com síndrome 7de Downno Brasil, e 23 lactentes do banco de dados por vídeo do Centro de Estudos de General Movements da Áustria. Resultados:O escore da avaliação foi significativamente menor do que em lactentescom desfecho neurológico comum. Quatorze lactentes com Síndrome de Down apresentaram Fidgety Movementsnormais, 13não apresentaram FMe 20 apresentaram FM exagerados, muito rápidos ou muito lentos. A falta de movimentos na linha média e várias posturas atípicas foram observadas. Nem o parto prematuro nem a cardiopatia congênita estavam associados apresença dos FM oua mobilidade reduzida. Conclusões:Para a indicação do uso dessa avaliação de baixo custo no Brasil:a observação motora contribui para a avaliaçãoqualitativado movimento global efuncional dolactentede uma maneira assertiva, rápida e não invasiva.Quanto arelevância daavaliação da qualidade dosmovimentosglobaisemlactentes com síndrome de Down:aheterogeneidade nos FM esuas características peculiares indicamque a intervenção deve serfeita o quanto antes para estimular e aprimorar o repertoriomotor.Os dados apontam que a identificação dos FM em crianças com síndrome de Down, pode ser um marcador clínico para o planejamento e intervenção fisioterapêutica singular; contudo sua ausência não pode ser utilizada como indicador de normalidade motorafuncionalou pretexto para adiarintervenções clínicas. Uma segunda conclusão aponta para inexistência de associação entre cardiopatias congênitas e FM em crianças com síndrome de Down. / Introduction-Asimportant as knowing \"what\" is changing in motor development, it is \"how\" and \"when\" these changes occur. The lack of these data still does not allow the description of this process in a linear and continuous way in groups with movement disorders, such as Down syndrome newborns. The memory can be a factor of differentiation in the case of motor performance and the construction of acquisition of the trajectory of the movement. Therefore, integration and its complete activation can be observed in the presentation of a rich motor repertoire in the spontaneous movement of infants. General purpose-To assessthe quality of spontaneous movement in infants with Down syndrome. Specific purposes-a) to describe information about the characteristics of this group of infants and the process of intervention in low-income countries; B) to analyze the applicability of the General Movements instrument in infants up to five months of life in low-and middle-income countries; C) to assess the spontaneous movement as facilitator of the mother-baby bond. Methods-review and elaboration of the thematic by searching in scientific databases at a first moment. Subsequent there was an exploratory study was conducted with the evaluation of 47 infants with Down syndrome by General Movements; in addition to filling out a questionnaire of information such as: the time the diagnosis is told to the parents, the time of breastfeeding, the period they stayed in the Intensive Care unit, the parents are employed, and the age of the parents. The evaluation was done at the Fidgety age (from 11 to 20 weeks after the term age). The data collection sites were: 24 infants from Darcy Vargas Children\'s Hospital and the APAE Institution of São Paulo (the hospital belongs to SUS -Sistema Único de Saúde),both represent reference sites for the care of children with Down syndrome, and 23infants from Austria data recorded. Results-The assessment score was significantly lower than in infants with a common neurological outcome. Fourteen infants with Down syndrome had normal FM, 13 had no FM and 20 had FM exaggerated, very fast or very slow. The 10lack of movements for the midline and several atypical postures were observed. Neither preterm birth nor congenital heart disease were related to FM or reduced mobility. Conclusions-for the indication in the use of the evaluation in Brazil:the researchers demonstrated that the quality motor observation contributes to the functional evaluation of the young nervous system. The application of GM assessment to vulnerable populations such as Brazil is therefore highly recommended. For the relevance of the evaluation applied to this group of infants with Down\'s syndrome:the research showsthat the heterogeneity in FM and its peculiar characteristicsjustify the early intervention.
60

Desenvolvimento de máquina universal de ensaios mecânicos portátil de baixo custo para fins didáticos utilizando o conceito open-source. /

Nakazato, Anderson Zenken January 2019 (has links)
Orientador: Luis Rogerio de Oliveira Hein / Resumo: Neste trabalho é apresentado o projeto e construção de uma Máquina Universal de Ensaios Mecânicos portátil, didática, de baixo custo, fácil construção seguindo a filosofia open-source com o intuito de dar suporte ao ensino de Mecânica e Resistência do Materiais. O equipamento foi projetado para ser construído com perfis modulares de alumínio e executado em uma oficina de ensino técnico em mecânica. A máquina é capaz aplicar de forma segura um carregamento máximo de 10 kN tanto em tração quanto em compressão, se mover em velocidades que variam de 0,5 a 70 mm/min com uma resolução no deslocamento de 0,57 μm a um custo total de US$ 1,000.00 incluindo material e fabricação. A máquina é controlada por uma placa Arduino® UNO, opera com acionamento eletromecânico, a aplicação de carga é feita por meio de fusos trapezoidais, a aquisição do deslocamento e velocidade da trave é feita por codificadores de quadratura e o controle de velocidade é feito por controle (Proporcional, Integral e Derivativo) PID e é capaz de realizar ensaios de tração, mas pode ser adaptada para outros ensaios como compressão, flexão e dobramento, entre outros. / Abstract: In this work is presented the design and construction of an easy to build low-cost portable Universal Testing Machine for educational purposes using the open-source philosophy. The intention of this project is to support the teaching in the subjects of Mechanics and Mechanics of Materials. The hardware was designed to be constructed with modular aluminum profiles and built in a conventional Mechanics Technical and Vocational Education and Training Laboratory. The machine can apply safely a maximum load of 10kN in both, traction and compression, move precisely in a range of speed from 0.5 to 70 mm/min with a resolution of 0,57 μm in a total cost of US$ 1,000.00 including necessary material and fabrication. The machine is controlled by an Arduino® UNO board, operated with an electromechanical activation. The loading is applied by trapezoidal lead screws, the displacement and speed acquisition are done by quadrature encoder and the speed is controlled by Proportional, Integral and Derivative (PID) control, it is capable do perform tensile tests, but may be adapted to other tests like compression, flexure and bending, and others. / Mestre

Page generated in 0.0766 seconds