• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 141
  • 7
  • 2
  • 1
  • Tagged with
  • 151
  • 85
  • 44
  • 28
  • 20
  • 19
  • 19
  • 19
  • 19
  • 19
  • 19
  • 18
  • 17
  • 14
  • 13
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Efeito do acompanhamento por telefone na recuperação cirúrgica de idosos submetidos à cirurgia de facectomia: estudo clínico randomizado

Delphino, Tallita Mello January 2016 (has links)
Submitted by Fabiana Gonçalves Pinto (benf@ndc.uff.br) on 2016-10-14T19:32:04Z No. of bitstreams: 1 Tallita Mello Delphino.pdf: 2292421 bytes, checksum: 1c5d2e29ee8a7afca245d4511f3ec3a5 (MD5) / Made available in DSpace on 2016-10-14T19:32:04Z (GMT). No. of bitstreams: 1 Tallita Mello Delphino.pdf: 2292421 bytes, checksum: 1c5d2e29ee8a7afca245d4511f3ec3a5 (MD5) Previous issue date: 2016 / Mestrado Acadêmico em Ciências do Cuidado em Saúde / Introdução: A cirurgia de facectomia tem sido cada vez mais freqüente, com isso, há necessidade de estratégias que auxiliem no seguimento pós-operatório com vistas a recuperação cirúrgica e minimização de complicações. Ao considerar a vulnerabilidade dos idosos a ocorrência de possíveis complicações pós-operatórias, definiu-se como itens de investigação os componentes do diagnóstico de enfermagem Recuperação cirúrgica retardada, proposto pela NANDA-I. Objetivos: Comparar a incidência do diagnóstico de recuperação cirúrgica retarda ao longo de 04 semanas no grupo acompanhado por telefone e no grupo controle; Analisar o acompanhamento telefônico para sujeitos em pós-operatório de facectomia no grupo experimento. Método: Trata-se de um estudo clínico randomizado cego para avaliação da efetividade do acompanhamento por telefone pela enfermeira na recuperação cirúrgica de idosos em pós-operatório de extração de catarata. A amostra do estudo consistiu em 95 participantes idosos com 60 anos ou mais de idade, em pré-operatório de cirurgia de catarata, provenientes do serviço de oftalmologia de dois hospitais localizados no município de Niterói-RJ, e que possuíssem telefone celular ou fixo disponível para o contato pela enfermeira. A amostra foi dividida em dois grupos Experimento e Controle, de forma randomizada, e foi obtida por cálculo amostral proposto por Pocock (1983). O grupo Experimento teve acesso à intervenção acompanhamento por telefone, que consistiu em 04 ligações no período das 04 semanas, realizada pela pesquisadora através de um protocolo de ligação semi-estruturado, como também acesso ao tratamento convencional. O grupo Controle teve acesso ao tratamento convencional sem o acompanhamento por telefone. O dois grupos foram acompanhados no ambulatório no 1º, 7º e 30º dia de pós-operatório durante 04 semanas para identificação da presença do diagnóstico de enfermagem recuperação cirúrgica retardada. Resultados: Houve ausência na primeira avaliação dos desfechos analisados em ambos os grupos. Na segunda avaliação, a ocorrência de recuperação cirúrgica retardada foi de 36,2% no grupo Controle e de 6,3% no grupo Experimento (p-0,000). A razão de chances (Odds Ratio = 0,118; Intervalo de Confiança = 0,032;0,437) indica a possibilidade de um efeito protetor do acompanhamento por telefone contra retardo na recuperação cirúrgica. Constatou-se também que o acompanhamento por telefone auxilia fortemente os pacientes na redução de chances de ocorrências de Evidência de interrupção na cicatrização da área cirúrgica (p-0,000); Relato de desconforto (p-0,001); Dor (p-0,003); Sentimento pós-operatório de ansiedade (p-0,000), Sentimento pós-operatório de preocupação(p-0,031), e Infecção pós-operatória no local da cirurgia (p-0,000). A ocorrência dessas características definidoras e fatores relacionados são significativamente menores no grupo experimento. Conclusão: Pacientes submetidos à intervenção acompanhamento por telefone têm chances significativamente reduzidas de apresentarem retardo na recuperação cirúrgica. O seguimento dos pacientes com orientações pós-alta auxilia principalmente na segurança e compreensão dos cuidados domiciliares, como também na detecção de complicações precocemente. / Introduction: Cataract surgery has been increasingly frequent, with this, there is need for strategies to assist in the postoperative follow-up to a full recovery and minimizing surgical complications. Considering the vulnerability of the elderly to possible occurrence of postoperative complications, defined as research items the components of the nursing diagnosis surgical recovery delayed, proposed by NANDA-I. Objectives: To compare the incidence of diagnosis of surgical recovery slows over 04 weeks in the group accompanied by telephone and in the control group; Analyze the telephone follow-up for subjects in cataract surgery after surgery in the experimental group. Method: This is a blind randomized clinical trial to evaluate the effectiveness of follow-up by phone the nurse in the surgical recovery in elderly postoperative cataract extraction. The study sample consisted of 95 elderly participants aged 60 or older in the preoperative period of cataract surgery, from the ophthalmology service of two hospitals located in Niterói-RJ, and possessing cell phone or landline available to contact the nurse. The sample was divided into two experiment groups and control, randomly, and was obtained by sample calculation proposed by Pocock (1983). Experiment group had access to intervention Telephone follow-up, which consisted of 04 bonds in the period of 04 weeks, conducted by researcher through a semi-structured connection protocol, as well as access to conventional treatment. The control group had access to conventional treatment without follow-up by telephone. The two groups were followed at the clinic on the 1st, 7th and 30th day postoperatively for 04 weeks to identify the presence of nursing diagnosis surgical recovery delayed. Results: There was absence in the first evaluation of the outcomes analyzed in both groups. In the second evaluation, the occurrence of delayed surgical recovery was 36.2% in the control group and 6.3% in the experiment group (p-0.000). The odds ratio (odds ratio = 0.118; confidence interval = 0.032; 0.437) indicates the possibility of a protective effect of telephone follow-ups against delay in surgical recovery. It was also found that monitoring by phone strongly supports patients in reducing chances of interruption Evidence of occurrences in the healing of surgical area (p-0.000); Reporting discomfort (p-0.001); Pain (p-0.003); Postoperative anxiety feeling (p-0.000), postoperative feeling of concern (p-0.031), and postoperative infection at the surgical site (p-0.000). The occurrence of these defining characteristics and related factors are significantly lower in the experimental group. Conclusion: Patients undergoing intervention Telephone follow-up have significantly reduced chances of presenting delay in surgical recovery. The follow-up of patients with post-discharge guidelines helps especially in safety and understanding of home care, as well as to detect complications early.
72

Optimización del cálculo de lentes intraoculares en base a la caracterización de la posición anatómica de la lente mediante reflectometría óptica de baja coherencia

Fukumitsu, Hideki 31 March 2023 (has links)
Tesis por compendio de artículos donde se realizó un estudio observacional, prospectivo donde se incluyeron 450 ojos que se han sometido una cirugía de la catarata a los cuales posteriormente se realizaron varias mediciones con un biómetro de reflectometría óptica de baja coherencia. Los objetivos fueron: en primero lugar valorar la consistencia de las medidas anatómicas, posteriormente caracterizar la posición de dos tipos de lentes intraoculares, definir un modelo de predicción y por último optimizar las fórmulas para el cálculo de la lente intraocular teniendo en cuenta el algoritmo de predicción. En conclusión, se ha observado que el biómetro proporciona mediciones anatómicas consistentes en ojos pseudofáquicos implantados con las dos lentes del estudio. Igualmente fue evidente que los cambios en la longitud axial tras la cirugía de cataratas pueden explicar el nivel de error en la predictibilidad refractiva obtenido mediante la fórmula de vergencia SRK-T. Con esto hemos podido definir una fórmula de estimación de la ELP para la fórmula SRK-T. Por último, los cambios en la refracción entre los meses 1 a 6 no están relacionados con la inestabilidad posicional de la LIO ni con los cambios en la longitud axial adicionales.
73

Correção da presbiopia pseudofácica através da implantação secundária de diafragma estenopeico no sulco ciliar / Pseudophakic presbyopia correction through secondary implantation of pinhole diaphragm in the ciliary sulcus

Trindade, Claudio Lovaglio Cançado 16 April 2019 (has links)
INTRODUÇÃO: A presbiopia pseudofácica, imposta pela extração do cristalino e implantação de uma lente intraocular monofocal, representa uma relativa limitação da cirurgia de catarata moderna. Diversos métodos para compensação de tal fenômeno já foram descritos. Nesse estudo, avaliamos a eficácia de um implante intraocular estenopeico em promover ampliação da profundidade de foco, e seu impacto no desempenho visual. MÉTODOS: Foram selecionados 10 pacientes hígidos, com boa saúde ocular, previamente submetidos a cirurgia de catarata bilateral com implante de lente intraocular monofocal, os quais apresentavam limitação da acuidade visual para perto. Os pacientes foram submetidos a implantação monocular do diafragma intraocular estenopeico XtraFocus®, no sulco ciliar. As variáveis avaliadas foram acuidade visual, refração subjetiva, sensibilidade ao contraste, amplitude de pseudoacomodação (curva de defocus), estereopsia, campimetria computadorizada, teste de efeito Pulfrich, e avaliação subjetiva do desempenho visual, através da aplicação de questionário. RESULTADOS: Houve significativa melhora da acuidade visual para perto, com 7 pacientes alcançando acuidade visual sem correção para perto de 20/30, no olho operado. Não houve impacto significativo na refração subjetiva, sensibilidade ao contraste e estereopsia. A perimetria computadorizada evidenciou redução de sensibilidade retiniana difusa, no olho operado. A percepção subjetiva do desempenho visual após o tratamento foi favorável, com impacto positivo nas atividades diárias. Não foi observada indução de efeito Pulfrich. CONCLUSÕES: O implante estenopeico estudado foi capaz de promover ampliação da profundidade de foco, com aprimoramento da acuidade visual para perto. O implantação cirúrgica se mostrou segura, sem ocorrência de eventos adversos significativos. Os resultados sugerem que uma maior independência de óculos pode ser alcançada caso a técnica seja aplicada em pacientes portadores de miopia de pequena magnitude. Este achado está em conformidade com trabalhos prévios envolvendo dispositivos estenopeicos. Apesar da limitação à entrada de luz imposta pelo orifício estenopeico, a percepção de luminosidade não é proporcionalmente impactada. Entretanto, em condições de baixa luminosidade, pode haver uma percepção monocular de escuridão / INTRODUCTION: Pseudophakic presbyopia, imposed by crystalline lens extraction and implantation of an artificial monofocal intraocular lens (IOL), represents a relative limitation of modern cataract surgery. Several methods of compensation of this phenomenon have been proposed. In this study, we evaluate the efficacy of a pinhole intraocular implant in promoting depth of focus extension, and its impact in visual performance. METHODS: A selection of 10 healthy patients, with no ocular comorbidity, previously submitted to bilateral cataract surgery and monofocal IOL implantation, presenting with near vision limitation, was carried out. Patients underwent monocular implantation of the XtraFocus® pinhole implant, in the ciliary sulcus. Outcome variables were visual acuity, subjective refraction, contrast sensitivity, amplitude of pseudoaccommodation (defocus curve), stereoacuity, automated perimetry, Pulfrich effect testing and subjective visual performance evaluation with a questionnaire. RESULTS: A significant improvement in near visual acuity was observed, with 7 patients reaching 20/30 uncorrected near visual acuity, in the operated eye. There was no significant impact in subjective refraction, contrast sensitivity and stereoacuity. Automated perimetry revealed a reduction of overall retinal sensitivity, in the operated eye. Subjective assessment of visual performance was favourable, with positive impact in daily activities. Induction of Pulfrich effect was not observed. CONCLUSIONS: The pinhole implant evaluated in this study was able to provide depth of focus extension, and enhance near visual acuity. Surgical implantation was safe, with no occurrence of significant adverse events. Results suggest that a greater level of spectacle independence may be achieved if this approach is combined with low levels of myopia. This finding is in accordance with other studies involving small aperture optics. In spite of the reduction of light entrance caused by the pinhole implant, the overall brightness sensation is not proportionally impaired. However, under low light conditions, a monocular darkening perception can occur
74

Estudo comparativo das estruturas do segmento anterior de olhos de cães com catarata, portadores e não portadores de Diabetes mellitus, avaliadas por biomicroscopia ultra-sônica / Comparison of anterior ocular segment structures in dogs with diabetic or no diabetic cataract, by ultrasound biomicroscopy

Galego, Marcia Pansera 11 December 2008 (has links)
A catarata, opacidade do cristalino ou da sua cápsula, representa uma das principais causas de cegueira em cães. A causa mais comum de catarata em cães é a alteração hereditária no metabolismo protéico da lente e a segunda, alterações metabólicas provocadas pelo Diabetes mellitus (DM). Esta é uma das endocrinopatias mais prevalentes em cães, caracterizada pela absoluta ou relativa deficiência de insulina. Altera o equilíbrio osmótico no interior da lente levando à catarata bilateral, simétrica e aguda, a qual a espécie canina é particularmente suscetível. A biomicroscopia ultra-sônica (UBM) é um método ultra-sonográfico de alta freqüência (50MHz) que permite a obtenção de imagens do modo B de qualidade microscópica. A resolução axial de 37µm, dez vezes maior que o ultra-som convencional, e a penetração limitada de cerca de 5 mm tornam o método adequado para exame das estruturas do segmento anterior ocular mesmo na presença de opacidade dos meios. Córnea, câmara anterior e ângulo iridocorneal podem ser avaliados em tempo real. Este estudo objetivou, por meio do uso da UBM, comparar as estruturas do segmento anterior de olhos de cães com catarata, diabética e não-diabética, para verificar possíveis alterações decorrentes do DM, considerando as particularidades da catarata diabética no cão. Os parâmetros avaliados foram espessura da córnea, profundidade da câmara anterior, aumento de celularidade no interior da câmara anterior e medida do ângulo iridocorneal. Foram realizados exames de 87 olhos de 47 animais da espécie canina (canis familiaris), 19 machos e 28 fêmeas de raças variadas e idade entre 02 e 14 anos, divididos em 3 grupos: grupo controle (GCO), grupo dos diabéticos (GDM) e o grupo de portadores de catarata não-diabéticos (GCAT). Os resultados revelam que o grupo dos diabéticos apresentou maiores espessuras de córnea que os demais grupos, com diferença estatisticamente significante na comparação com GCO e com GCAT. O grupo controle apresenta maiores câmaras anteriores e há diferença estatisticamente significante entre GCO e GCAT. Quando analisadas as medidas do ângulo iridocorneal, não houve diferença estatisticamente significante entre os 3 grupos. No grupo controle não houve registro da presença de ecos puntiformes, indicativos de aumento de celularidade na câmara anterior, que foram encontrados em 34,2% dos cães com catarata não diabética e em 29% dos cães diabéticos. Há, portanto, diferença estatisticamente significante entre o GCO e o GCAT e entre o GCO e GDM. Com base no que foi aferido, permite-se concluir que olhos de cães diabéticos com catarata apresentam maior espessura de córnea central que olhos de cães com catarata de outras etiologias e de cães normais, que há diminuição da câmara anterior em olhos de cães com catarata, quando comparados a cães normais e que não há diferença na medida do ângulo iridocorneal em olhos de cães com catarata, diabética ou não, e de cães normais. / Cataracts is the opacity of the lens or its capsule and represent the leading cause of blindness in dogs. The most common cause of cataract in dogs is a result of inherited alteration of the lens protein metabolism, metabolic alterations caused by Diabetes mellitus (DM) are the second most common cause. This is one of the most prevalent endocrinopathy in dogs and results from an absolute or relative deficiency of insulin. It changes the osmotic balance inside the lens causing bilateral, symmetric and acute cataracts, which the dog is particularly susceptible to. Ultrasound biomicroscopy (UBM) is a high-frequency (50MHz) ultrasonographic method that produces B mode images of microscopic quality. With a 37µm image axial resolution, which is ten times higher than conventional ultrasound, and penetration restricted to about 5mm, it comprises an adequate method for the examination of structures of the ocular anterior segment, even in cases of opacities. The cornea, the anterior chamber and the iridocorneal angle can be real time evaluated. The objective of this study was, by means of UBM use, to compare the anterior segment structures of the canine eyes, both with diabetic and non-diabetic cataract, in order to detect changes caused by DM, bearing in mind the peculiarities of diabetic cataract in dogs. The parameters evaluated were: cornea thickness, anterior chambers depth, increased cellularity inside the anterior chamber, and iridocorneal angle measurement. Eighty-seven eyes of 47 animals of the canine family (canis familiaris) were examined. Nineteen were males and 28 females of several breeds, from 2 to 14 years of age, divided into three groups: control- without any ocular alteration (GCO), diabetic (GDM), and non-diabetic cataract (GCAT). The results showed that the diabetic group presented a statistically significant higher cornea thickness than the other groups. The control group showed deeper anterior chambers and also a statistically significant difference between GCO and GCAT. When the iridocorneal angle measurements were analyzed, it was found that there were no statistically significant differences between the three groups. The control group showed no punctiform echoes - those are suggestive of the increase in cellularity in the anterior chamber these echoes, however, were found in 34,2% of the dogs with non-diabetic cataract and in 29% of the diabetic ones. There is, therefore, a statistically meaningful difference between the CGO and the other two groups (GCTA and GDM). Based on theses results, we can conclude that: the eyes of diabetic dogs with cataract showed a central cornea higher thickness compared to the eyes of dogs with cataract of different etiologies, and to dogs with normal eyes; there is a decrease of the anterior chamber depth in the eyes of dogs with cataract compared to normal eyes, there is no significant difference between the iridocorneal angle measurement in the eyes of dogs with cataract, diabetic or not, and normal dogs.
75

Avaliação morfológica e molecular do epitélio e cápsula anterior da lente de cães com catarata, submetidos à facoemulsificação com o uso do azul de tripano a 0,1% / Morphologic and molecular evaluation of the epithelium and anterior capsule of the canine lens, with cataracts, after surgery utilizing 0.1% trypan blue during capsulorrexis

Hvenegaard, Ana Paula Franco do Amaral 31 March 2015 (has links)
A remoção cirúrgica da catarata é uma intervenção cada vez mais praticada na medicina veterinária e, com ela, diversos estudos têm sido realizados com o intuito de reduzir as possíveis complicações de seu pós-operatório, tal como a opacidade da cápsula posterior, alteração ocasionada principalmente pela diferenciação e migração das células do epitélio lenticular para a cápsula posterior da lente. O objetivo deste estudo foi analisar a morfologia da cápsula anterior e seu epitélio pela coloração de rotina com hematoxilina-eosina; a composição molecular da cápsula pelas técnicas histoquímicas de PAS (avaliação de proteoglicanos) e picrosirius red (avaliação de colágeno IV); além da expressão de morte celular nas células epiteliais pelas técnicas de imunofluorescência com Beclina 1 (autofagia) e Caspase 3 (apoptose), em cães idosos com catarata diabética e não diabética do tipo hipermadura, submetidos ao uso ou não de azul de tripano a 0,1 % durante a cirurgia de remoção da catarata por facoemulsificação. Para o estudo, foram estudadas as células epiteliais e cápsula anterior da lente de 27 cães, sendo 21 fêmeas e 6 machos, de 8 a 12 anos de idade (média = 9,6 anos), de diversas raças, que foram primeiramente divididos em 2 grupos: GC (catarata hipermadura) e GCD (catarata diabética) e, depois, subdivididos em outros 4 grupos: os que utilizaram o corante: GAND (catarata hipermadura com azul de tripano) e GAD (catarata diabética com azul de tripano); e os que não foram submetidos ao uso do corante: GND (catarata hipermadura sem azul de tripano) e GD (catarata diabética sem azul de tripano). Os resultados das análises realizadas observaram que ambas as amostras, tanto as provenientes das cataratas hipermaduras, quanto as diabéticas, sofrem alterações em igual intensidade apesar do diferente processo de formação, ou seja, observou-se que houve positividade na expressão de morte celular do epitélio por apoptose e autofagia em igual intensidade e independente da utilização de azul de tripano a 0,1 % em todos os grupos; que a composição molecular da cápsula quanto à quantidade de proteoglicanos e colágeno IV também é semelhante e que, apesar da cápsula apresentar-se mais espessada do que o normal, ainda preserva sua relação anatômica com o epitélio. Conclui-se, portanto, que as lesões ocasionadas pela formação da catarata diabética e hipermadura no epitélio e em sua membrana basal (cápsula) são semelhantes apesar da diferente fisiopatologia de formação, mas que o epitélio e a cápsula ainda preservam sua relação anatômica e morfologia. Com os resultados, também se pode sugerir que cães que apresentem cataratas destes tipos, devam apresentar menor risco de ocorrência de opacidade na cápsula posterior no pós cirúrgico da catarata / Nowadays, surgical removal of cataracts in dogs is being considered a common intervention. Along with that, many studies have been realized aiming to reduce its post operatory complications, such as the posterior lens capsule opacity, which occurs due to epithelium cells differentiation and migration to the posterior pole. The objective of this study was to evaluate, by morphometry (hematoxilin-eosin), histochemistry (PAS and picrosirius red) and immunofluorescence (Caspase 3 and Beclin 1) analysis: the morphological alterations of the lens anterior capsule and its epithelium; the molecular components of the extracellular matrix; and the expression of lens epithelium cellular death (by autophagy and apoptosis), in elderly diabetic and non diabetic dogs with cataracts, after phacoemulsification surgery utilizing or not 0,1 % trypan blue. Twenty seven dogs, including 21 female and 6 male dogs, with ages varying from 8 to 12 years old (mean = 9.6 yo), of different breeds were studied. Animals were first divided into 2 groups: GC (hypermature cataracts) and GCD (diabetic cataracts); then, subdivided in 4 different groups: GAND (non diabetic dogs with trypan blue), GAD (diabetic dogs with trypan blue), GND (non diabetic dogs without trypan blue) and finally, GD (diabetic dogs without trypan blue). Results showed that both types of studied samples (diabetic and hypermature ones), are equally altered besides its different pathophysiology, since no statistical significant differences were observed in both capsule and epithelium thickness, type IV collagen and proteoglycans concentration and also, in the epithelium cells autophagy and apoptosis, observed by Caspase 3 and Beclin 1 expression in every studied group. In addition, 0,1 % trypan blue was not capable to demonstrate its toxicity rate, as cells were already under the referred death processes. In conclusion, our findings suggests that, besides the differences in both, hypermature and diabetic cataracts, pathophysiologies of formation, serious and similar alterations are observed with the same intensity in the anterior lens capsule and its epithelium in dogs, what must probably reduce posterior lens capsule opacity post phacoemulsification surgery
76

Mensuração da sensibilidade corneana e produção lacrimal em cães submetidos à facoemulsificação / Corneal sensitivity and tear production measurement in dogs submitted to phacoemulsification

Góes, Ana Carolina Almeida de 26 February 2014 (has links)
A facoemulsificação é, atualmente, considerada a técnica de eleição no tratamento da catarata, uma das principais causas de perda de visão, em cães. O procedimento demanda a realização de incisões na córnea para acesso à câmara anterior. Tais incisões, a despeito da extensão reduzida, podem lesar a inervação da córnea, comprometendo sua sensibilidade e, consequentemente, influenciar a produção lacrimal. Objetivando-se avaliar tais intercorrências, concebeu-se aferir a sensibilidade corneana e a produção lacrimal aquosa em cães submetidos à facoemulsificação. Para tanto, tais parâmetros foram investigados em 20 cães com idade, sexo, raça e peso variáveis. Os procedimentos cirúrgicos foram realizados em um único olho (OT), sendo o olho não operado utilizado como controle (OC). A sensibilidade da córnea foi mensurada com o estesiômetro de Cochet-Bonnet® e a produção lacrimal pelos testes do fenol vermelho e de Schirmer, em ambos os olhos. Os parâmetros foram aferidos previamente ao procedimento cirúrgico (M0 - valores basais) e, posteriormente, após sete dias (M1), 15 dias (M2), 30 dias (M3), 90 dias (M4) e 180 dias (M5). Os valores da produção lacrimal aferida com o teste do fenol vermelho, em M1, não diferiram dos obtidos previamente à cirurgia (M0), nos OT e OC; diferenças significativas foram observadas de M2 a M5, com valores superiores aos basais (M0), em ambos os olhos. Os resultados da mensuração lacrimal com o teste de Schirmer e da sensibilidade corneana à estesiometria (em cm e mm/g2) não diferiram dos basais (M0) em quaisquer dos períodos de avaliação (M1 a M5), em ambos os olhos. Os resultados obtidos ao estudo permitiram verificar que a realização da cirurgia de catarata por facoemulsificação, como fora proposto, não resulta em diminuição da sensibilidade corneana e produção lacrimal aquosa. / Phacoemulsification is considered the technique of choice for surgical extraction of cataracts, which is a leading cause of blindness in dogs. The procedure requires corneal incisions to enter the anterior chamber. These incisions, despite their reduced extensions, may damage the corneal innervation, compromising its sensitivity and, also, the tear production. Aiming to evaluate these consequences, this study intended to measure the corneal sensitivity and aqueous tear production in dogs undergoing phacoemulsification. These parameters were evaluated in 20 dogs, with different ages, genders, breeds and weights. Surgical procedures were performed in one eye (OT), and the fellow eye was used as a control (OC). Corneal sensitivity was measured with the Cochet-Bonnet® aesthesiometer and tear production by the phenol thread red test and Schirmer tear test, in both eyes. The parameters were measured prior to the surgery (M0 - baseline values) and after seven days (M1), 15 days (M2), 30 days (M3), 90 days (M4) and 180 days (M5). Tear production values measured with the phenol red test, in M1, were not different from the values measured prior to the surgery (M0), in OT and OC; significant differences were noticed from M2 to M5, with higher values when compared to baseline values (M0), in both eyes. Schirmer tear test and corneal sensitivity (in cm and mm/g2) values were not different from basal values (M0) in any of the evaluation times (M1 to M5), in both eyes. Our study outcomes suggest that phacoemulsification, as proposed previously, does not decrease the corneal sensitivity and aqueous tear production.
77

Avaliação eletrorretinográfica pré e pós-operatória em cães diabéticos submetidos à facoemulsificação / Electroretinografic evaluation before and after phacoemulsification in diabetic dogs

Gomes, Débora 30 September 2013 (has links)
Diabete Melito (DM) é uma endocrinopatia frequentemente diagnosticada na clínica de pequenos animais e desenvolve-se pela deficiência relativa ou absoluta de insulina, sendo caracterizada pela hiperglicemia crônica. Complicações associadas ao DM são frequentes, dentre elas podemos citar catarata e retinopatia. A catarata, que é a oftalmopatia mais frequente nos cães, impossibilita à fundoscopia e nestes casos a avaliação da função retiniana pode ser feita com o auxílio do eletrorretinograma de campo total. O objetivo deste estudo foi avaliar a progressão da retinopatia diabética por meio de eletrorretinograma (ERG) de campo total pré e pós-operatória (180 dias) em cães portadores de catarata madura e hipermadura submetidos à facoemulsificação. Vinte e quatro cães (Grupo Diabético (DM) = 12 cães; Grupo Não Diabético (NDM) = 12 cães) de raças diversas foram avaliados. Previamente ao ERG, todos os cães foram submetidos ao exame oftalmológico completo e ultrassom ocular. Todos os cães foram sedados seguindo o mesmo protocolo. ERG de campo total foi realizado com sistema eletrodiagnóstico Veris 2000 e cúpula de estimulação (Ganzfeld), segundo o protocolo da ISCEV contendo 5 respostas. Para obtenção dos registros utilizou-se eletrodo bipolar Burian Allen. Avaliou-se a amplitude pico a pico das 5 respostas e o tempo de culminação da onda-b na resposta de bastonetes, máxima resposta, cones e flicker para cada registro em condições escotópicas e fotópicas. As respostas obtidas em cada olho no momento basal e após 6 meses foram comparadas por meio do teste de Wilcoxon. O teste de Mann-Whitney foi utilizado para comparação de respostas dos olhos operados (OP) com os olhos contralaterais (OC), assim como para comparação entre os grupos DM e NDM. O efeito da cirurgia e do tempo de DM foi ainda avaliado por meio do cálculo das diferenças entre as respostas no momento pré e pós 6 meses de cada olho (delta OP e delta OC). Observou-se diferenças entre OP e OC, no momento pré, nas respostas dos bastonetes e da máxima resposta (amplitude e tempo de culminação onda-b). No momento pós, foram observados diferenças entre OP e OC no tempo de culminação dos bastonetes e flicker, e nas amplitudes do potencial oscilatório, cones e flicker. No grupo NDM, não foram observados diferenças entre os momentos pré e pós assim como entre OP e OC. Quando comparadas as respostas dos grupos DM e NDM, observou-se valores significativamente maiores no grupo DM, no tempo de culminação da onda-b na máxima resposta do OP no momento pós, no tempo de culminação da onda-b na máxima resposta OC no momento pós e no tempo de culminação da onda-b da resposta de cones no momento pré cirurgia. Não foram observados diferenças entre delta OP e delta OC dentro de cada grupo e entre os grupos. Todos os pacientes que participaram do estudo recuperaram a visão após a cirurgia, sugerindo que a inflamação pós cirúrgica foi controlada com a medicação prescrita nos 2 grupos estudados. Conclui-se que a facoemulsificação representa mínimo impacto na evolução da retinopatia diabética em cães. A remoção cirúrgica da catarata não deve ser contraindicada nesta espécie, independentemente se o animal é ou não portador de DM, por resultar em melhoria da visão. / Diabetes mellitus (DM) is a common endocrinopathy in the small animals practice and it develops as a relative or absolute insulin deficiency characterized by a chronic hyperglycemia. There are frequent complications, such as cataracts, retinopathy, resulting in visual impairment. Cataracts are dogs most frequent ophthalmic affection and, since it prevents fundoscopic examination, full-field electroretinography is used for retinal functional evaluation. Therefore, to provide a better understanding of diabetic retinopathy (DR) progression in dogs with mature and hypermature cataracts undergoing phacoemulsification surgery, this study aims to analyze the full-field electroretinogram prior and 180 days post cataracts removal. Twenty four dogs (diabetic group (DM) = 12 dogs and non-diabetic group (NDM) = 12 dogs), from different breeds were evaluated. Before the ERG, all animals were submitted to a complete ophthalmic examination and ocular ultrasonography. All dogs were sedated following the same anesthetic protocol. The full-field ERG was recorded using 2000 VERIS system and a dome stimulator (ganzfeld) according to ISCEV five response standard. The recordings were obtained using bipolar Burian Allen electrodes. Peak to peak amplitude five response and b-wave culmination time in rod responses, maximum response, cone and flicker were evaluated in scotopic and photopic conditions. The responses obtained in each eye at baseline and after 6 months were compared using the Wilcoxon test. The Mann-Whitney test was used to compare the responses of the operated eyes (OP) and the contralateral eyes (OC) as well as for comparison between groups DM and NDMAs. The effect of surgery and duration of DM was assessed by calculating the differences between the responses prior and six months after surgery, of each eye (delta delta OP and OC). There were differences between OP and OC, in the baseline values, in rod responses and maximum response (amplitude values and b-wave implicit time). After phacoemulsification, differences were observed between OP and OC in b-wave implicit time of rods and flicker, and the amplitudes of the oscillatory potentials, cone and flicker. In the NDM group, no differences were observed between pre and post evaluations between OP and OC. Comparing the responses of DM and NDM groups, there were significantly higher values in the DM group, in b-wave implicit time and in maximum response of OP after caratact removal, and also, of the b-wave implicit time in the maximum response in OC after surgery and, finally, in the b-wave implicit time of cone response prior to the surgery. No differences were observed between delta OP and delta OC within each group and between groups. All patients recovered vision after surgery, suggesting that post-surgery inflammation was controlled by the prescribed medication in both groups. The phacoemulsification surgery did not appear to have a great impact on diabetic retinopathy evolution in dogs. Cataract surgery should not be contraindicated in this species, regardless of the presence of DM, as it can result in sight improvement.
78

Eliciação e comunicação de requisitos em domínios disjuntos: estudo de caso para a área médica. / Requirements elicitation and comunication of different domain: study of case of medical area.

Queiroz, Ricardo Alexandro de Andrade 08 February 2007 (has links)
A Engenharia de Requisitos (ER) vem sendo reconhecida como uma área de pesquisa de extrema relevância para o desenvolvimento de sistemas ou artefatos. As maiores causas de falhas ocorridas em projetos são oriundas do processo de aquisição e tradução dos objetivos, necessidades ou restrições estabelecidas pelos clientes e/ou usuários. Estes erros podem aumentar de forma exponencial em projetos que se propõem a desenvolver sistemas ou artefatos que estejam diretamente associados à área cirúrgica, devido a diferença do domínio de conhecimento e o vocabulário entre as mencionadas áreas. Desta forma, verifica-se a importância científica para desenvolver modelos ou métodos que minimizem o problema apresentado. Ajudar na análise e definição, de maneira apurada e precisa, junto ao especialista da área médica, em relação aos movimentos executados em um procedimento minimamente invasivo e auxiliar a área de projetos de engenharia a desenvolver esse tipo de sistema. Este trabalho de dissertação apresenta o desenvolvimento de um modelo de conduta para o processo de eliciação e comunicação de requisitos no cenário em que o desenvolvedor e o especialista pertencem a diferentes domínios, técnicas e linguagens próprias. É também realizada a aplicação prática do modelo, em uma cirurgia minimamente invasiva, em específico à cirurgia da catarata. A aplicação prática foi realizada com o total apoio do Hospital Santa Luzia e do Instituto da Catarata, UNIFESP. / In recent years, the requirements engineering process has become known as a research with extreme relevance for system development. The major failures in projects are caused by the translation requirements, i.e. the task of communicating with customers and users to determine what their requirements are. These mistakes can rise exponentially in system development projects that are directly associated with the area of surgery, because of the difference of knowledge domain and the vocabulary between the mentioned areas (engineering and medicine). In this way rises the scientific importance for models development or methods that minimize the problem presented above. Helping analyzing and defining, in a fine and accurate way, a long with a specialist from the medical area, relating the movements executed in the minimally invasive process and help the area of engineering design develop this type of system. Considering this, we propose in this dissertation the development of a model that show elicitation process and a communication of requirements in a scenario in which the developer and stackholder pretence a different types of domain, techniques and proper languages. The model is also practices in a minimally invasive surgery, especially in cataract surgery. It was practiced with the full support of Santa Luzia Hospital, and the Institute of Cataract, UNIFESP.
79

Influência da ceratometria e profundidade de câmara anterior obtidas por biometria óptica e por sistema Scheimpflug na predição do poder dióptrico de lente intraocular multifocal calculada para emetropia / Influence of keratometry and anterior chamber depth obtained by partial coherence interferometry and Scheimpflug system in the accuracy of intraocular multifocal lens diopter power calculated for emmetropia

Andrade Junior, Newton 26 September 2018 (has links)
Influência da ceratometria e profundidade de câmara anterior obtidas por interferometria de coerência parcial e por sistema Scheimpflug na acurácia do poder dióptrico de lente intraocular multifocal calculada para emetropia [Tese]. São Paulo: Faculdade de Medicina, Universidade de São Paulo; 2018. Objetivo: Verificar se a ceratometria média (K) e a profundidade de câmara anterior (ACD) obtidos por biometria óptica (IOLMaster® 500) e por sistema Scheimpflug (Pentacam® HR) influenciam na predição do cálculo do poder dióptrico de LIO multifocal programada para emetropia. Métodos: Estudo clínico retrospectivo de 198 olhos portadores de catarata senil, tratados com facoemulsificação e implante de LIO multifocal. A diferença entre o valor da ¨LIO ideal¨, previsto pela fórmula biométrica de HAIGIS para emetropia e o poder dióptrico da LIO implantada foi denominada \"desvio teórico da emetropia\" (TDE). Foram testados quatro cenários de cálculo de LIOs, combinando as medidas K e ACD obtidas com os dois dispositivos. Resultados: No trigésimo dia de pós-operatório, o equivalente esférico foi 0 D em 118 dos 198 olhos (60%). O IOL Master® 500 e Pentacam® HR diferiram em relação à média de K (delta 0,09 ± 0,02 D, p < 0,001) e ACD (delta 0,08 ± 0,01 mm; p < 0,001). De acordo com a análise de covariância, o TDE foi 0,17 ± 0,01 D para K e ACD mensurados com IOL Master® 500; 0,27 ± 0,01 D para K e ACD obtidos com Pentacam® HR; 0,15 ± 0,01 D para K gerados com IOL Master® e ACD medidos com Pentacam® HR e 0,28 ± 0,01 D para K mensurado com Pentacam® HR e ACD obtido com IOL Master®. O TDE foi menor quando K foi medido com IOL Master® 500, independente de qual dispositivo foi usado para medir ACD. Conclusões: As predições foram menos confiáveis usando o K gerado pelo Pentacam® HR (diferença média > 0,25D), a despeito de qual equipamento tenha gerado a ACD / Objective: To compare the postoperative refractive predictability of IOL Master® 500 and Pentacam® HR based on K and ACD values in eyes with indication for multifocal IOLs. Methods: Clinical retrospective study of 198 consecutive eyes treated with phacoemulsification and multifocal IOL implantation. The difference between the predicted value and the ideal IOL diopter was termed theoretical deviation from emmetropia (TDE). Using Haigis\' formula, the IOL closest to emmetropia was chosen. Four lens calculation scenarios were tested by combining K and ACD measurements obtained with the two devices. Results: On the 30th postoperative day, the spherical equivalent was 0 D in 118 of the 198 eyes (60%). IOL Master® and Pentacam® HR differed with regard to mean K (delta 0.09 ± 0.02 D; p < 0.001) and ACD (delta 0.08 ± 0.01 mm; p < 0.001). According to the analysis of covariance, TDE was 0.17 ± 0.01 D for K and ACD measured with IOL Master®, 0.27 ± 0.01 D for K and ACD measured with Pentacam HR; 0.15 ± 0.01 D for K measured with IOL Master® and ACD measured with Pentacam® HR, and 0.28 ± 0.01 D for K measured with Pentacam HR and ACD measured with IOL Master®. Mean K was the only statistically significant factor (p < 0.001). Thus, TDE was smaller when K was measured with IOL Master® 500, regardless of which device was used to measure ACD. Conclusion: Predictions were less reliable using the K generated by Pentacam® HR (average difference > 0,25D), regardless of which equipment has generated the ACD
80

Potencial visual evocado por flashes de luz em cães diabéticos com catarata / Flash visual evoked potential in diabetic dogs with cataract

Lustoza, Adriana Cabral 16 December 2008 (has links)
Os cães têm apresentado uma maior prevalência de DM nos últimos anos, sendo uma das endocrinopatias mais comuns. As complicações a curto e longo prazo incluem alterações retinianas, renais e neurológicas. Dentre as alterações mais evidentes podemos citar o desenvolvimento de cataratas e alterações nas vias visuais. As alterações das vias visuais são detectadas precocemente por testes eletrofisiológicos, métodos objetivos que independem da informação do paciente e necessitam de pouca colaboração para serem executados. Neste estudo utilizamos o PVE-F, que consiste em potenciais de baixa amplitude registrados quando a retina é submetida à estimulação visual adequada em uma cúpula de campo total, e avalia a integridade das vias ópticas desde a retina até o córtex occipital. Com este estudo objetivamos avaliar as alterações das vias visuais do PVE-F em cães diabéticos portadores de catarata, consoante os critérios da ISCEV. Para o projeto foram utilizados 59 cães, selecionados quanto aos melhores registros e com menor interferência, com idade variando entre 5 e 14 anos, de pequeno à médio porte (até 20kg) de diferentes raças, 46 fêmeas e 13 machos, encaminhados ao Serviço de Oftalmologia do Hospital Veterinário da Faculdade de Medicina Veterinária e Zootecnia da Universidade de São Paulo. Os animais foram divididos em 3 grupos: grupo normal (GN) cães adultos hígidos; grupo catarata (GC) cães apresentando catarata madura ou hipermadura; grupo diabético (GD) cães apresentando catarata madura ou hipermadura, com diabetes mellitus. Todos os grupos foram analisados quanto à latência (ms) e quanto à amplitude (V). O registro do PVE foi obtido por eletrodos de contato superficial utilizando o Sistema Eletrodiagnóstico Computadorizado Veris 2000 com frequência de 2Hz totalizando 180 estímulos. Os animais permaneceram com a cabeça introduzida no interior da cúpula geradora dos flashes de luz branca (Ganzfeld) durante todo o exame. Os potenciais foram registrados em ambos os olhos, no olho direito (ocluindo olho esquerdo) e posteriormente no olho esquerdo (ocluindo olho direito). Em relação ao pico P2 houve semelhança entre os olhos examinados, porém os valores das médias do GD foram maiores que os demais, com significância estatística ao GN (p=0,001) e ao GC (p=0,000). O GD apresentou valores de médias: AO 97,72ms; OD 98,10ms e OE 97,21ms. O GC apresentou valores de médias: AO 86,73ms; OD 86,27ms e OE 86,87ms. O GN apresentou valores de médias: AO 73,20ms; OD 74,53ms e OE 74,33ms. A amplitude (µV) dos intervalos N1-P1, P1-N2 e P2-N2 mostrou semelhança entre os grupos estudados (GN, GC e GD). Porém, os intervalos P1-N2 e N2-P2 apresentaram diferenças entre os olhos, com valores de médias de AO maiores em relação ao OD e OE estatísticamente significantes (p=0,000). No estudo realizado, os valores de glicemia estavam maiores no GD, com uma média de 202,79 mg/dl, enquanto que o GN apresentou média de 78,47 mg/dl e o GC 74,80 mg/dl. Conclui-se que as alterações nas vias visuais estão presentes nos cães diabéticos independentemente do tempo de DM, idade e controle glicêmico, e o PVE-F é um teste útil e importante capaz de detectar estas alterações. / Dogs have been frequently affected by Diabetes mellitus; nowadays, one of the commonest endocrinopathy in this specie. It causes short and long term complications in different organs, such as eyes, kidneys and nervous system. The most evident complication seen in DM dogs is the diabetic cataract and the alterations of the visual pathway. Most of the visual pathway alterations are early diagnosed by electrophysiological tests, objective methods which doesn´t need patient information and requires minimal co-operation to be performed. The aim of this study was to evaluate the integrity of the optic pathway, from the retina to the occipital cortex, in diabetic dogs with cataracts using the PVE-F test and the ISCEV standards. PVE-F is an electrophysiological test based on the registration of low amplitude potentials urged from the retina when stimulated by full field dome. The exam was performed at the Ophthalmology Service, of the Veterinary Hospital of the Veterinary College University of São Paulo in fifty-nine animals, including 46 female and 13 male dogs, with ages varying from 5 to 14 years and weighting less than 20kg. Dogs were divided in 3 groups: healthy dogs without ocular alterations (GN); healthy dogs with mature or hyper mature cataract (GC); diabetic dogs presenting mature or hyper mature cataract (GD). PVE-F was realized using Veris 2000 Computerized Electrodiagnostic System, adjusted for 2Hz flashes (180 flashes) while dogs, with superficial contact electrodes, were kept with their heads inside the generator dome of white light flashes (Ganzfeld). Registers were obtained from both eyes - AO; right eye - OD (occluding left eye) and left eye - OE (occluding right eye) and those with less interference were chosen. Latencies (ms) and amplitudes (V) in each group were analyzed separately. Similarity at peak P2 was observed in every examined eye, but mean values on GD were higher when compared to other groups, with statistically significance on GN (p=0,001) and GC (p=0,000) as shown: (GD): AO 97,72ms, OD 98,10ms and OE 97,21ms; (GC): AO 86,73ms, OD 86,27ms and OE 86,87ms; (GN) AO 73,20ms, OD 74,53ms and OE 74,33ms. Similarity at amplitude (µV) intervals N1-P1, P1-N2 and P2-N2 was observed in every studied group (GN, GC and GD). On the other hand, difference in P1-N2 and N2-P2 intervals registers were observed when comparing eyes: both eyes mean values were higher than OD and OE values, with statistically significance (p=0,000). Glycemic values were higher in GD, with mean values of 202,79 mg/dl, whereas GN was 78,47 mg/dl and GC 74,80 mg/dl. These study demonstrates that diabetic dogs presents alterations at the visual pathway function, independent of the DM time, age and glycemic control and that PVE-F is an important and useful test able to detect such alterations.

Page generated in 0.0322 seconds