• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 92
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • Tagged with
  • 92
  • 92
  • 25
  • 25
  • 17
  • 17
  • 14
  • 11
  • 11
  • 10
  • 9
  • 9
  • 9
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Aplicação do recurso de subtração radiografica digital na avaliação da região perimplantar

Bittar-Cortez, Juliana Araujo 02 February 2005 (has links)
Orientador: Francisco Haiter Neto / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-14T19:27:31Z (GMT). No. of bitstreams: 1 Bittar-Cortez_JulianaAraujo_M.pdf: 3295326 bytes, checksum: 3905a9f6f1bc2ee984cad244a6df872b (MD5) Previous issue date: 2005 / Resumo: O exame radiográfico após a instalação de implantes endósseos é um importante meio auxiliar de diagnóstico para se avaliar as alterações no tecido ósseo adjacente, pois durante as fases de reparo e remodelação, no primeiro ano após a implantação ocorre uma redução do osso marginal. Foi proposto investigar o uso da subtração radiográfica digital na avaliação da região perimplantar em um estudo in vivo. Trinta e quatro pacientes foram monitorados através de radiografias periapicais convencionais padronizadas, no primeiro acompanhamento pósoperatório após a cirurgia para instalação de implantes endósseos e quatro meses após, antes da segunda fase cirúrgica, ao final do período de remodelação óssea. As radiografias foram digitalizadas e imagens de subtração radiográfica digital foram criadas por meio de um programa de computador denominado EMAGO. Os dois tipos de imagens, digitalizadas e subtração radiográfica digital, foram comparadas quantitativamente a partir de medidas de densidade óssea, obtidas por meio do histograma de uma área selecionada e por meio de medidas lineares da altura óssea presente avaliando também a reprodutibilidade interobservadores. Dentro das condições deste estudo, concluiu-se que a subtração radiográfica digital tem uma capacidade de diagnóstico semelhante à imagem digitalizada convencional na avaliação de densidade óssea, entretanto, medidas de altura óssea podem ter valores mais próximos do real utilizando imagens de subtração, mas essas medidas apresentam uma variabilidade inter-observadores / Abstract: Radiographic evaluation in connection with implant installation is an important means of diagnosing changes in bone tissue around the implant, where during the healing and the early remodeling phases, a slight reduction of the marginal bone height occurs in the first year after implant placement. The proposition for this research was to validate the use of the digital subtractionradiography in the perimplant region assessment in an in vivo study. Thirty four patients were monitored by standardized periapical conventional radiography in thefirst postoperative follow-up after surgery for implant placement and four months later, prior to the second-stage surgery at the end of the healing period. The radiographs were digitized and digital subtraction radiography was created by means of EMAGO software. The two types of images, digitized and digitalsubtraction radiography, were compared quantitatively by measuring bone density of a selected area by the histogram and by assessing bone height with linear measurements and also evaluating the reproducible inter-observers. Within the limits of this study, it was concluded that digital subtraction radiography has similar diagnostic performance to those of conventional digitized radiography in evaluating bone density however, bone height can be more precisely assessed with the subtraction images but the measurements has an inter-observers variability / Mestrado / Radiologia Odontologica / Mestre em Radiologia Odontológica
82

Análise densitométrica digital do processo de reparo em dentes de rato reimplantados

Giovanini, Ellen Greves [UNESP] 30 November 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:25:20Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-11-30Bitstream added on 2014-06-13T20:13:38Z : No. of bitstreams: 1 giovanini_eg_me_araca.pdf: 1544057 bytes, checksum: 1b518f21ba8bc63249a3f29eb78ba402 (MD5) / A avulsão dentária é caracterizada pelo completo deslocamento do dente do seu alvéolo e a melhor forma de tratar um dente avulsionado é o seu reimplante. Mesmo diante das melhores circunstâncias os reimplantes tardios falham devido à reabsorção radicular que é detectada apenas durante a avaliação radiográfica. A imagem digital surgiu como um recurso diagnóstico rápido e de fácil utilização sendo considerada precisa. Para diminuir a variabilidade de interpretação é sugerida a análise radiográfica quantitativa por meio da densidade radiográfica. O propósito deste trabalho foi analisar comparativamente o processo de reparo do reimplante dental em ratos utilizando a análise densitométrica no sistema digital Digora. Foram utilizados 30 ratos machos, divididos em 3 grupos de 10 animais, que tiveram seu incisivo superior direito extraído e tratado da seguinte forma: grupo I - reimplante imediato, grupo II - reimplante tardio sem tratamento e o grupo III - reimplante tardio com tratamento da superfície radicular utilizando raspagem do ligamento e fluoreto de sódio. Os animais foram sacrificados após 60 dias do ato operatório, suas maxilas foram separadas e as imagens radiográficas obtidas de forma que sobre cada placa óptica ficassem as duas hemimaxilas (tratada e controle), o penetrômetro de alumínio e a identificação. Foram realizadas medidas de densidade em áreas padronizadas no sistema Digora. Os valores densitométricos encontrados foram submetidos à análise de variância e teste de Tuckey, e análise não paramétrica do número de áreas de reabsorção. Podemos concluir que a análise densitométrica constitui um importante exame complementar para o acompanhamento dos reimplantes uma vez que permitiu a detecção de reabsorção radicular em todos os grupos, cuja ordem decrescente de envolvimento foi o grupo do reimplante tardio sem tratamento... / The dental replanted has been considered the best treatment of the tooth avulsion, which is characterized by complete alveolar dislodgment of the tooth. Despite of the adequate clinical situations, the delayed replantation fails due to the root resorption that is detected during the radiographic evaluation. The use of the digital image represent a fast and easy diagnostic resource, furthest more precise. The quantitative radiographic analysis has been suggested to reduce the interpretation variability through the radiographic density. The purpose of this work was to analyze the process of repair of the dental replanted using the digital densitometry in the Digora system. The 30 male rats were divided in 3 groups of 10 animals, and their right superior incisor were extracted and treated agreement with their group: group I - immediate replanted, group II - delayed replanted without treatment and the group III - delayed replanted with treatment of the root surface using fluoride of sodium. The animals were sacrificed after 60 days operative act, your jawbones were separate and the radiographic images obtained so that on each optical plate were the two jawbones (treated and control), the aluminum step wedge and the identification. The radiographic density of radicular standardized area in Digora system was measured. The densitometric values were submitted to the variance analysis and test of Tuckey and analysis non parametric of the number of areas root resoption. We can end that digital densitometry analysis it an important complementary for replanted evaluation once it allowed the detection of root reabsorption in all of the groups, whose decreasing order of involvement was the group of the delayed replanted without treatment, following for the delayed replanted with treatment and last the immediate replanted.
83

Avaliação das condições de radioproteção em radiologia intraoral

Miguel, Cristiano 20 March 2015 (has links)
Este estudo apresenta a avaliação das condições de radioproteção em radiologia intraoral. A pesquisa foi realizada em parceria com o Instituto de Radioproteção e Dosimetria da Comissão Nacional de Energia Nuclear (IRD/CNEN). A coleta de dados foi feita por meio de pesquisa de campo quantitativa de caráter descritivo durante o período de setembro de 2013 a dezembro de 2014. Participaram voluntariamente do estudo, odontólogos da cidade de Curitiba - PR que atuam com equipamentos de raios X intraorais. A amostra da pesquisa consistiu em 97 odontólogos e 130 equipamentos intraorais instalados em 74 locais de atendimentos distribuídos em 39 bairros da cidade de Curitiba - PR. Foram avaliadas 21 clínicas odontológicas, 40 consultórios odontológicos, 1 hospital universitário, 8 unidades municipais de atendimento odontológico e 4 instituições de ensino. Os dados foram coletados por meio de formulários preenchidos pelo pesquisador, pelos odontólogos, e pela avaliação de controle de qualidade dos equipamentos de raios X. As avaliações de dose de entrada na pele, tamanho de campo de radiação e filtração total foram realizadas com kits dosimétricos fornecidos e avaliados pelo IRD/CNEN. As medidas do tempo de exposição e da tensão dos equipamentos de raios X foram realizadas com detectores não invasivos. A dose ocupacional dos odontólogos foi verificada com dosímetros termoluminescentes. Por meio de formulários e de um questionário (aprovado pelo Comitê de Ética em Pesquisa de Seres Humanos - UTFPR) foi possível identificar as características técnicas dos equipamentos, avaliar os procedimentos de trabalho e o conhecimento dos odontólogos em relação à radioproteção. Com os resultados da pesquisa é possível destacar que apenas 10% dos equipamentos avaliados atendem a todas as exigências das normas de radioproteção do Brasil. Entretanto, 84,5% das doses de entrada na pele dos pacientes foram consideradas como conforme. Em relação à exposição ocupacional, a radiologia intraoral mostra-se segura, porém os procedimentos de trabalho dos odontólogos, referentes à radioproteção podem ser otimizados. Grande parte dos odontólogos não utiliza posicionador na sua rotina, fazem o processamento químico das radiografias através do método visual, usam sempre o mesmo tempo de exposição para todas as regiões anatômicas e não observam os pacientes durante a aquisição das imagens. O estudo sugere que a falta de conhecimento e de interesse dos odontólogos em relação à radioproteção, a falta de manutenção periódica dos equipamentos e a falta de fiscalização da agência regulamentadora são os responsáveis pelas não conformidades observadas. / This study presents an evaluation of the radiation protection conditions in intraoral radiology. The survey was conducted in partnership with the Radiation Protection and Dosimetry Institute of the National Commission of Nuclear Energy (IRD/CNEN). Data collection was performed using quantitative field research in a descriptive way during the period of september 2013 to december 2014. The study had the voluntarily participation of dentists in the city of Curitiba – PR, working with intraoral X-ray equipment. The research sample consisted of 97 dentists and 130 intraoral equipments which are installed in 74 care locations distributed in 39 neighborhoods in the city of Curitiba - PR. The study evaluated 21 dental clinics, 40 dental offices, 1 hospital, 8 municipal units of dental care and 4 educational institutions. Data were collected through forms checked out by the researcher, by dentists and the quality control evaluation of X-ray equipment. The evaluation of the entrance skin dose, radiation field size and total filtration were performed with dosimetric kits supplied and evaluated by IRD/CNEN. The exposure time and voltage measures of X-ray equipment were performed with noninvasive detectors. Occupational dose was measured with thermoluminescent dosimeters. Through appropriate forms and a questionnaire (approved by the Ethics Committee of Human being Research - UTFPR) it was possible to identify the technical characteristics of the equipment, review the working procedures and knowledge of the dentists in relation to radiation protection. Among the search results it is important to emphasize that only 10% of the evaluated equipment reaches all requirements of the Brazilian radiation protection standards. However, 84,5% of the entrance skin dose delivered to the patients was considered in accordance. Regarding occupational exposure, the intraoral X-rays seem to be safe, but the dentist’s working procedures, related to the radiation protection, can be optimized. Most dentists do not use positioners in their routine, make the chemical processing of X-rays through the visual method, routinely use the same exposure time for all anatomic regions and do not observe patients during image acquisition. The study suggests that the dentists’s lack of knowledge and interest in radiological protection, the lack of equipment regular maintenance and the lack of regulatory agency supervision are the responsible for the nonconformities observed.
84

Avaliação das condições de radioproteção em radiologia intraoral

Miguel, Cristiano 20 March 2015 (has links)
Este estudo apresenta a avaliação das condições de radioproteção em radiologia intraoral. A pesquisa foi realizada em parceria com o Instituto de Radioproteção e Dosimetria da Comissão Nacional de Energia Nuclear (IRD/CNEN). A coleta de dados foi feita por meio de pesquisa de campo quantitativa de caráter descritivo durante o período de setembro de 2013 a dezembro de 2014. Participaram voluntariamente do estudo, odontólogos da cidade de Curitiba - PR que atuam com equipamentos de raios X intraorais. A amostra da pesquisa consistiu em 97 odontólogos e 130 equipamentos intraorais instalados em 74 locais de atendimentos distribuídos em 39 bairros da cidade de Curitiba - PR. Foram avaliadas 21 clínicas odontológicas, 40 consultórios odontológicos, 1 hospital universitário, 8 unidades municipais de atendimento odontológico e 4 instituições de ensino. Os dados foram coletados por meio de formulários preenchidos pelo pesquisador, pelos odontólogos, e pela avaliação de controle de qualidade dos equipamentos de raios X. As avaliações de dose de entrada na pele, tamanho de campo de radiação e filtração total foram realizadas com kits dosimétricos fornecidos e avaliados pelo IRD/CNEN. As medidas do tempo de exposição e da tensão dos equipamentos de raios X foram realizadas com detectores não invasivos. A dose ocupacional dos odontólogos foi verificada com dosímetros termoluminescentes. Por meio de formulários e de um questionário (aprovado pelo Comitê de Ética em Pesquisa de Seres Humanos - UTFPR) foi possível identificar as características técnicas dos equipamentos, avaliar os procedimentos de trabalho e o conhecimento dos odontólogos em relação à radioproteção. Com os resultados da pesquisa é possível destacar que apenas 10% dos equipamentos avaliados atendem a todas as exigências das normas de radioproteção do Brasil. Entretanto, 84,5% das doses de entrada na pele dos pacientes foram consideradas como conforme. Em relação à exposição ocupacional, a radiologia intraoral mostra-se segura, porém os procedimentos de trabalho dos odontólogos, referentes à radioproteção podem ser otimizados. Grande parte dos odontólogos não utiliza posicionador na sua rotina, fazem o processamento químico das radiografias através do método visual, usam sempre o mesmo tempo de exposição para todas as regiões anatômicas e não observam os pacientes durante a aquisição das imagens. O estudo sugere que a falta de conhecimento e de interesse dos odontólogos em relação à radioproteção, a falta de manutenção periódica dos equipamentos e a falta de fiscalização da agência regulamentadora são os responsáveis pelas não conformidades observadas. / This study presents an evaluation of the radiation protection conditions in intraoral radiology. The survey was conducted in partnership with the Radiation Protection and Dosimetry Institute of the National Commission of Nuclear Energy (IRD/CNEN). Data collection was performed using quantitative field research in a descriptive way during the period of september 2013 to december 2014. The study had the voluntarily participation of dentists in the city of Curitiba – PR, working with intraoral X-ray equipment. The research sample consisted of 97 dentists and 130 intraoral equipments which are installed in 74 care locations distributed in 39 neighborhoods in the city of Curitiba - PR. The study evaluated 21 dental clinics, 40 dental offices, 1 hospital, 8 municipal units of dental care and 4 educational institutions. Data were collected through forms checked out by the researcher, by dentists and the quality control evaluation of X-ray equipment. The evaluation of the entrance skin dose, radiation field size and total filtration were performed with dosimetric kits supplied and evaluated by IRD/CNEN. The exposure time and voltage measures of X-ray equipment were performed with noninvasive detectors. Occupational dose was measured with thermoluminescent dosimeters. Through appropriate forms and a questionnaire (approved by the Ethics Committee of Human being Research - UTFPR) it was possible to identify the technical characteristics of the equipment, review the working procedures and knowledge of the dentists in relation to radiation protection. Among the search results it is important to emphasize that only 10% of the evaluated equipment reaches all requirements of the Brazilian radiation protection standards. However, 84,5% of the entrance skin dose delivered to the patients was considered in accordance. Regarding occupational exposure, the intraoral X-rays seem to be safe, but the dentist’s working procedures, related to the radiation protection, can be optimized. Most dentists do not use positioners in their routine, make the chemical processing of X-rays through the visual method, routinely use the same exposure time for all anatomic regions and do not observe patients during image acquisition. The study suggests that the dentists’s lack of knowledge and interest in radiological protection, the lack of equipment regular maintenance and the lack of regulatory agency supervision are the responsible for the nonconformities observed.
85

Efeito do design da união soldada a TIG e a laser, em estruturas usinadas em liga de Ti-6AI-4V e fundidas em titânio comercialmente puro, sobre a resistência à ciclagem mecânica / Effect of TIG and laser welded joints with different designs executed in machined Ti-6Al-4V and casted pure titanium strutures on the mechanical cycling resistance

Nuñez-Pantoja, Juliana Maria Costa 17 August 2018 (has links)
Orientador: Marcelo Ferraz Mesquita / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-17T15:29:22Z (GMT). No. of bitstreams: 1 Nunez-Pantoja_JulianaMariaCosta_D.pdf: 1479308 bytes, checksum: ee8715e20b041116b795969befba2c72 (MD5) Previous issue date: 2011 / Resumo: Este estudo avaliou a resistência à ciclagem mecânica de estruturas confeccionadas em liga de Ti-6Al-4V e em Ti cp, submetidas à soldagem a laser (L) e ao procedimento TIG de soldagem (TIG), com variação de design das uniões, e correlacionar esses resultados com dados obtidos na análise radiográfica dessas soldas. Para o primeiro ensaio, foram obtidos 70 corpos de prova (halteres) usinados em liga de Ti-6Al-4V, com 3,5 mm de diâmetro de secção transversal e, para o segundo ensaio, outros 70 foram fundidos em Ti cp. Os corpos de prova foram seccionados em duas partes iguais e as partes a serem unidas foram limpas e alinhadas, segundo os designs da união: em "I", variando as distâncias de soldagem (0,0mm (I00) ou 0,6mm (I06)), ou em "X" (X). As variáveis design da união e tipo de soldagem foram cruzadas entre si formando um total de 6 grupos, que associadas ao grupo controle (intactos) totalizaram 7 grupos (n=10): G1- Intacto; G2- L/I00; G3- L/I06; G4- L/X; G5- TIG/I00; G6- TIG/I06; G7- TIG/X, para cada ensaio. Os corpos de prova foram soldados a laser utilizando-se 360V/8ms (X) e 390V/9ms (I00 e I06), com foco e freqüência regulados em zero. As soldas TIG foram realizadas utilizando-se os seguintes parâmetros de soldagem: 2:2 (X) e 3:2 (I00 e I06). As uniões receberam acabamento, polimento e foram submetidas à análise radiográfica (90 kV, 15 mA, 0,6 seg e 12 mm de distância), para verificação de poros no interior das soldas. Posteriormente, foi realizado o ensaio de resistência à ciclagem mecânica, e o número de ciclos até a fratura foi registrado. As superfícies de fratura foram analisadas em microscópio eletrônico de varredura. Os testes de Kruskal-Wallis e Dunn (?=0,05) mostraram que para ambos os procedimentos de soldagem, a pior maneira de se realizar a união se dá com I00, e a melhor, com X (p<0,05), para ambos os metais. Apenas para L, I06 foi tão resistente quanto X, tanto para o Ti cp quanto para Ti-6Al-4V. Quando são comparados os dois procedimentos de união, para os dois materiais, o teste de Mann-Whitney (?=0,05) mostrou haver diferença entre as soldas para I00 e I06, sendo que a união soldada a laser foi a mais resistente. Quando foram comparados os grupos com seus respectivos controles, notou-se que para o Ti-6Al-4V, nenhum grupo soldado foi tão resistente quanto os intactos; já para o Ti cp, os grupos com design X, para as duas soldas, foram tão resistentes quanto o controle, assim como o I06 soldado a laser. O coeficiente de correlação de Spearman (?=0,05) indicou correlação negativa entre número de ciclos resistidos e presença de poros nas radiografias das uniões dos materiais testados. Pode-se concluir que a união soldada com design em "X" dev0e ser empregada quando se pretende soldar a TIG corpos de prova de 3,5 mm de diâmetro de secção transversal. Quando é empregada a solda a laser, pode ser utilizado o design em "I" com 0,6 mm de espaçamento entre as partes, além do design em "X". / Abstract: The aim of this study was to evaluate the fatigue strength of Ti-6Al-4V alloy and pure titanium (cp TI) structures, submitted to laser (L) and TIG (TIG) welding procedures, varying the design of the joints, and correlate these results with joints radiographic analyses data. For the first test, 70 dumbbell rods with central diameters of 3.5 mm were obtained by lost-wax casting procedure in cp Ti, and others 70 were machined in Ti-6Al-4V alloy, for the second test. The specimens were sectioned in 2 equal parts, perpendicular to the rods long axis. The parts to be weld were cleaned and aligned according to joint designs: "I" design, varying welding distances (0.0 mm (I00) or 0.6 mm (I06)), or "X" (X) design. The variables joint design and type of welding were crossed creating 6 groups, that associated to the control group (intact), totaled 7 groups (n=10): G1- Intact; G2- L/I00; G3- L/I06; G4- L/X; G5- TIG/I00; G6- TIG/I06; G7- TIG/X, to each test. Laser-welding was executed using 360V/8ms (X) and 390V/9ms (I00 e I06) with focus and frequency regulated at zero. The TIG welding were executed using 2:2 (X) and 3:2 (I00 and I06) as welding parameters. The joints were finished, polished and submitted to radiographic examination (90 kV, 15 mA, 0.6 second and 12 mm of distance), for pores verification within the joints. Later, the rods were submitted to mechanical cyclic tests, and the number of cycles until fracture was recorded. The fracture surface was examined with a scanning electron microscope. Kruskal-Wallis and Dunn test (?=0.05) indicated that for both welding procedures, the worst way to perform the joint occurs with I00, and the best, with X (p<0.05), for both metals. To L, I06 was as resistant as X. When both type of welding are compared, to both materials, the Mann-Whitney test (?=0.05) indicates difference to I00 and I06, being the laser-weld joint the better one. When groups were compared with their respective control groups, it was noticed for Ti-6Al-4V that none of the joint groups was as resistant as the intact; on the contrary to cp Ti the "X" design groups, welded by TIG or L were as resistant as control, even as I06 laser-welded. The Spearman correlation coefficient (?=0.05) indicated a negative correlation between number of cycles and presence of porosity in radiographies of both materials. It could be concluded that the "X" design can be employed to weld 3.5 mm in diameter structures by laser or TIG welding procedure. When laser welding procedure is used, the "I" design with a space of 0.6 mm between parts can also be employed. / Doutorado / Protese Dental / Mestre em Clínica Odontológica
86

Avaliação da radiopacidade, do pH e da atividade antimicrobiana do MTA, do cimento Portland puro e do cimento Portland adicionado de agentes radiopacificadores

Lima, Marta Judite Nunes 26 February 2016 (has links)
Introduction: The radiopacity is a required property in all dental materials. This characteristic allows this materials be able to be distinguished from the tooth surfaces through the radiography. Portland cement (PC) presents physico-chemical and biological properties similar to mineral trioxide aggregate (MTA), except for radiopacifier. Objective: To evaluate the radiopacity, antimicrobial activity and pH of the MTA, pure PC and PC added different radiopacifiers. Materials and Methods: The radiopacity of MTA, pure PC and PC added the radiopacifying: iodoform, lead oxide, zirconium oxide, bismuth subnitrate, barium sulfate and bismuth oxide in the proportions 15%, 20% and 30% were analyzed. The radiopacity was carried out using a semi-direct digital radiography system (Instrumentarium Kavo EXPRESS®). The PC and cements selected with adequate radiopacity (ANSI/ADA No. 57) were evaluated for their antimicrobial activity and pH. Antimicrobial activity was analyzed by microdilution tests and agar diffusion. The microorganism tested were Enterococcus faecalis, as a standard strain (ATCC 29212) and six clinical strains (LMA 26, LMA 27, LMA 28, LMA 29, LMA 31 and LMA 34). The pH was measured using a digital pH meter (pH Meter Pocket-sized). Statistical analyzes were performed using the Shapiro-Wilk normality test, ANOVA and Tukey with significance level of 5%. Results: Pure PC had the lowest radiopacity. The MTA, PC + iodoform 20% (3.59 mmEq.Al), PC + bismuth oxide 20% (4.79 mmEq.Al), PC + bismuth subnitrate 20% (3.12 mmEq.Al), PC + 20% lead oxide (3.18 mmEq.Al) and PC + 30% zirconium oxide (4.28 mmEq.Al). Regarding the agar diffusion test, the LMA 26 strain was inhibited by PC, PC + Iodoform 20%, PC + 30% Zirconium Oxide, PC + Bismuth subnitrate 20%, and PC + Bismuth Oxide 20%. The LMA 31 strain was inhibited by PC + zirconium oxide 30% and PC + bismuth subnitrate 20% and LMA 27 strain was inhibited by PC + bismuth subnitrate 20%. The other strains were not inhibited. In the microdilution test, most strains was inhibited by tested materials, except the ATCC 29212 strain which was not inhibited by PC + lead oxide 20%. LMA 28 29, 31 and 34 strains were not inhibited by PC + lead oxide 20%and PC + zirconium oxide 30%, in which LMA 28 and 29 strains were not inhibited by PC + bismuth oxide20%. All cements tested showed alkalinity in all experimental periods, in which MTA had the lowest pH. Conclusions: MTA and PC added the radiopacifiers subnitrate bismuth and iodoform in concentrations of 20% by weight, provided satisfactory radiopacity, alkaline medium and promoted bactericidal and bacteriostatic activities against strains of E .faecalis tested. / Introdução: A radiopacidade é uma propriedade obrigatória em todos os materiais odontológicos. Esta característica permite este material seja distinguido das superfícies dentárias através da radiografia. O cimento Portland (CP) apresenta propriedades físicoquímicas e biológicas semelhantes ao Agregado Trióxido Mineral (MTA), exceto pela partícula radiopacificadora. Objetivo: Avaliar a radiopacidade, atividade antimicrobiana e pH do MTA, CP puro e CP adicionado de diferentes radiopacificadores. Materiais e Métodos: Foi analisada a radiopacidade do MTA, CP e CP adicionado dos radiopacificadores: iodofórmio, óxido de chumbo, óxido de zircônio, subnitrato de bismuto, sulfato de bário e óxido de bismuto nas proporções 15%, 20% e 30%. A radiopacidade foi avaliada por meio do sistema de radiografia digital semi-direto (Instrumentarium Kavo EXPRESS®). O CP e os cimentos selecionados com radiopacidade adequada (ANSI/ADA nº 57) foram submetidos à avaliação da atividade antimicrobiana e do pH. A atividade antimicrobiana foi analisada pelos testes de microdiluição e difusão em ágar. O micro-organismo testado foi o Enterococcus faecalis, sendo uma cepa padrão (ATCC 29212) e seis cepas clínicas (LMA 26, LMA 27, LMA 28, LMA 29, LMA 31 e LMA 34). O pH foi aferido com pHmetro digital (pH Meter Pocket-sized). Os testes estatísticos utilizados foram os testes Shapiro-Wilk de normalidade, análise de variância ANOVA e Tukey a nível de significância de 5%. Resultados: O CP puro apresentou o menor valor de radiopacidade, O MTA, CP + iodofórmio 20% (3,59 mmEq.Al), CP + óxido de bismuto 20% (4,79 mmEq.Al), CP + subnitrato de bismuto 20% (3,12 mmEq.Al), CP + óxido de chumbo 20% (3,18 mmEq.Al) e CP + óxido de zircônio 30% (4,28 mmEq.Al). No teste de difusão em ágar, a cepa LMA 26 foi inibida pelo CP, CP + Iodofórmio 20%, CP + Óxido de Zircônio 30%, CP + Subnitrato de Bismuto 20% e CP + Óxido de Bismuto 20%. A cepa LMA 31 foi inibida pelas associações CP + óxido de zircônio 30% e CP + subnitrato de bismuto 20% e a cepa LMA 27 foi inibida pelo CP + subnitrato de bismuto 20%. As demais cepas não foram inibidas. No teste de microdiluição, a maioria das cepas foi inibida pelos materiais-testes, exceto a cepa ATCC 29212 que não foi inibida pelo CP + óxido de chumbo 20%, as cepas LMA 28, 29, 31 e 34 não foram inibidas pelas associações CP + óxido de chumbo 20% e CP + óxido de zircônio 30%, sendo que as cepas LMA 28 e 29 também não foram inibidas pelo CP + óxido de bismuto 20%. Todos os cimentos testados apresentaram alcalinidade em todos os períodos experimentais, sendo que o MTA apresentou os menores valores de pH. Conclusões: O MTA e as concentrações de CP adicionado de 20% do agente radiopacificador subnitrato de bismuto e CP adicionado do agente radiopacificador iodofórmio, 20% em peso, proporcionaram radiopacidade satisfatória, alcalinizaram o meio e promoveram atividades bactericida e bacteriostática contra as cepas de E. faecalis testadas.
87

Sistema de avaliação de qualidade de imagem em radiologia digital odontologica / Image quality evaluation system for dental digital radiology

Leão, Tiago Freire Carneiro 13 August 2018 (has links)
Orientador: Eduardo Tavares Costa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-13T16:14:16Z (GMT). No. of bitstreams: 1 Leao_TiagoFreireCarneiro_M.pdf: 2505362 bytes, checksum: 6d6b07198f62fd7206b28e629cc5ba41 (MD5) Previous issue date: 2009 / Resumo: Novas tecnologias e sistemas de detecção de radiação para a geração de imagens radiográficas odontológicas vêm sendo disponibilizados como alternativa aos filmes radiográficos. Sistemas baseados em tecnologia do tipo PSPL parecem superar algumas das restrições encontradas nos sistemas baseados em tecnologia CCD, tais como volume do detector, cabos de conexão, tamanho limitado da imagem e limitação da latitude. É importante que seja possível comparar sistemas de imagem concorrentes (diferentes tecnologias ou diferentes fabricantes com mesma tecnologia), utilizando ferramentas e protocolos de controle e certificação de qualidade. Foi desenvolvido um pacote computacional e um conjunto de simuladores e foi realizada a análise de dois sistemas comerciais baseados na tecnologia PSPL, de forma a validar o sistema desenvolvido. O programa desenvolvido permite obter e analisar: curva sensitométrica, função de transferência de modulação (MTF), densidade espectral de potência (NPS), quanta equivalente de ruído (NEQ) e eficiência na detecção de quanta (DQE). Os resultados mostraram que o pacote computacional e o conjunto de simuladores permitem realizar o controle de qualidade de sistemas de radiografia digital odontológica de maneira quantitativa e objetiva, facilitando a análise comparativa entre diferentes sistemas comerciais. Palavras-chave: Radiologia digital odontológica, controle de qualidade em radiodiagnóstico, curva sensitométrica, detecção equivalente de quanta, função de transferência de modulação, densidade espectral de ruído, quanta equivalente de ruído. / Abstract: New systems and technologies for radiation detection intended for dental radiology have become available as an alternative to dental radiographic film. Systems based on PSPL technology seems to overcome some of the restrictions of systems based on CCD technology such as the bulky detector, connecting wire, limited image size and limited exposure latitude. It is important that competing imaging systems can be compared (different technologies or different manufacturers of the same technology) by means of quality control tools and quality certification protocols. A software package and a set of specific phantoms were developed and the analyses of two competing PSPL systems were conducted to validate the developed system. The software allows the user to obtain and analyze: the characteristic curve, modulation transfer function (MTF), noise power spectrum (NPS), noise equivalent quanta (NEQ) and detective quantum efficiency (DQE). The results have shown that the developed software and phantom set allow quality control of digital dental radiology systems in a very objective and quantitative way, facilitating comparative analysis of competing commercial systems. Keywords: Digital dental radiology, quality assurance in radiodiagnostic, characteristic curve, detective quantum efficiency, modulation transfer function, noise power spectrum, noise equivalent quanta. / Mestrado / Engenharia Biomedica / Mestre em Engenharia Elétrica
88

Elaboração de um guia de referência com imagens radiográficas para aplicação em exames extraorais odontológicos / Elaboration of a reference guide with radiograpich images for application in dental extraoral exams

Mickus, Joice 27 October 2017 (has links)
Os exames radiológicos são importantes recursos no auxílio da elaboração um diagnóstico odontológico preciso. Contudo, só devem ser realizados quando houver uma real indicação clínica, visto que os efeitos das radiações ionizantes no organismo humano são cumulativos. Falhas na execução de procedimentos radiológicos resultam em imagens com qualidade diagnóstica duvidosa, sendo necessária, muitas vezes, a repetição de exames. Desta forma, métodos para minimizar a rejeição imagens radiológicas devem ser observados. A fim de colaborar para a diminuição dos erros de posicionamentos e consequente rejeição de exames de imagem na área da odontologia, este estudo teve por objetivo a criação de um guia de referência para aplicação em exames extraorais odontológicos. Para a elaboração e estruturação deste guia, foi realizado um estudo com o intuito de identificar os motivos de rejeição de radiografias panorâmicas em um serviço de radiologia odontológica digital. O estudo foi retrospectivo e por meio de uma busca no software de aquisição de imagens, foram selecionadas 2306 radiografias panorâmicas digitais, correspondentes a 10% do total de exames realizados entre os anos de 2013 a 2015. A partir da amostra, foram identificados os exames rejeitados e as causas da rejeição. Ainda para colaborar com o desenvolvimento do guia de referência, foi aplicado um questionário aos profissionais técnicos/tecnólogos atuantes no setor de radiologia onde a pesquisa foi realizada. O questionário contou com nove perguntas relacionadas à rotina de trabalho do setor. Com os resultados obtidos na pesquisa foi possível a elaboração do guia de referência com imagens radiográficas para aplicação em exames odontológicos. / The radiological exams are important resources in aid of drafting a dental diagnosis. However, should only be performed when there is a real clinical indication, since the effects of ionizing radiation on the human body are cumulative. Flaws in the implementation of radiological procedures result in doubtful quality diagnostic images, being necessary, many times, the repetition of exams. In this way, methods to minimize radiological images rejection must be observed. In order to contribute to the reduction of errors of positioning and consequent rejection of imaging examinations in the area of dentistry, this study had as its objective the creation of a reference guide for application in dental extraoral examinations. For the preparation and structuring of this guide, a study was conducted with the aim of identifying the reasons for the rejection of panoramic radiographs in a digital dental radiology service. The study was retrospective and by means of a search in the software of image acquisition, were selected 2306 digital panoramic radiographs, corresponding to 10% of the total number of examinations performed between the years of 2013 and 2015. From the sample, were identified the rejected exams and the causes of rejection. To collaborate with the development of the reference guide, a questionnaire was applied at technical professionals working in the radiology sector where the research was conducted. The questionnaire was attended by nine questions related to routine work in the sector. With the results obtained in the study it was possible to do the preparation of the guide of reference with radiographic images for application in dental examinations.
89

Avaliação de doses em órgãos radiossensíveis expostos durante exames de tomografia computadorizada por feixe cônico e radiografia panorâmica / Dosimetry of radiosensitive organs exposed during cone beam computed tomography and panoramic radiograph

Heiden, Katia Regina 07 October 2016 (has links)
A radiografia panorâmica e a tomografia computadorizada por feixe cônico (TCFC) são métodos de imagem amplamente utilizados na Odontologia, pois fornecem uma visão geral do complexo dentomaxilofacial, sendo importantes no diagnóstico e tratamento de lesões que acometem esta região. A radiografia panorâmica é considerada um procedimento de baixa dose e a TCFC apresenta doses inferiores quando comparada à tomografia computadorizada (TC). Apesar de baixas, as doses provenientes destes exames expõem órgãos radiossensíveis, como tireoide e glândulas salivares, aos riscos da radiação ionizante. Conhecer os níveis de radiação à que estes órgãos estão expostos é importante para a escolha adequada do método de imagem e parâmetros de exposição a serem utilizados, reduzindo os riscos associados à radiação ionizante, conforme o princípio de radioproteção ALARA (As Low As a Reasonably Achievable - tão baixo quanto razoavelmente exequível). O objetivo deste estudo foi avaliar as doses absorvidas por estes órgãos radiossensíveis durante a realização de radiografias panorâmicas e exames de TCFC, utilizando diferentes parâmetros de exposição. Dosímetros termoluminescentes (TLDs - Thermoluminescent Dosimeters) foram inseridos em um phantom antropomórfico Alderson Radiation Therapy (ART) para identificar as doses absorvidas pela tireoide e glândulas salivares, em um equipamento de radiografia panorâmica e dois equipamentos de TCFC, com diferentes protocolos. As doses absorvidas variaram de 0,01 a 0,22 mGy na tireoide e de 0,26 a 2,96 mGy nas glândulas salivares. Na TCFC as doses variaram de acordo com o protocolo selecionado, porém foram superiores às doses de uma radiografia panorâmica. Os protocolos de TCFC que utilizaram longos tempos de exposição, considerados como protocolos de alta resolução, resultaram em doses superiores quando comparados aos protocolos que utilizaram baixos tempos de exposição. Protocolos que utilizaram campos de visão (FOVs - Fields Of View) maiores, expuseram a tireoide a níveis mais altos de radiação. Diante dos resultados obtidos, pode-se concluir que a TCFC somente deve ser solicitada caso a informação diagnóstica não possa ser obtida através da radiografia panorâmica, sendo a escolha adequada dos fatores técnicos imprescindível para reduzir a dose de radiação durante a realização de exames de TCFC. / Panoramic radiograph and cone beam computed tomography (CBCT) are imaging methods widely used in dentistry because they provide an overview of dentomaxillofacial complex, being important in the diagnosis and treatment of lesions that affect this region. Panoramic radiograph is considered a low-dose procedure and CBCT presents lower doses when compared with computed tomography (CT). Although low, the doses from these imaging methods expose radiosensitive organs, such as thyroid and salivary glands, to the risks of ionizing radiation. Knowing the levels of radiation these organs are exposed is important to select the appropiate imaging method and exposure parameters to be used, reducing the risks associated with ionizing radiation, according to the principle of radioprotection ALARA (As Low As a Reasonably Achievable). The aim of this study was to evaluate the absorbed doses by these radiosensitive organs during the course of panoramic radiographs and CBCT examinations, using different exposure parameters. Thermoluminescent dosimeters (TLDs) were inserted into an anthropomorphic phantom Alderson Radiation Therapy (ART) to identify the absorbed doses by the thyroid and salivary glands, in a panoramic x-ray unit and two CBCT units with different protocols. Absorbed doses ranged from 0.01 to 0.22 mGy in the thyroid and 0.26 to 2.96 mGy in the salivary glands. Doses in CBCT varied according to the selected protocol, but were higher than the dose of a panoramic radiograph. The CBCT protocols that used long exposure times, considered as high-resolution protocols, resulted in higher doses compared to protocols that used low exposure times. Protocols that used fields of view (FOVs) higher, exposed the thyroid at higher levels of radiation. Based on the results obtained, it can be concluded that CBCT should only be requested if the diagnostic information can’t be obtained through the panoramic radiograph and the appropriate choice of technical factors essential to reduce the radiation dose during examinations CBCT.
90

Caracterização elementar de filtros de alumínio de equipamentos de raios X odontológicos intrabucais

França, Alana Caroline 19 February 2014 (has links)
A busca pela qualidade radiográfica com a menor dose de radiação absorvida é uma constante na comunidade radiológica. Juntamente com o princípio ALARA (As Low As Reasonably Achievable), os filtros de alumínio são peças fundamentais para barrar os fótons de baixa energia que não contribuem para a imagem e depositam dose de radiação para o paciente. De acordo com a Portaria n°453, a Agência Nacional de Vigilância Sanitária decretou que todos os equipamentos de raios X odontológicos intrabucais devem possuir a filtração adicional. Nesse sentido, os filtros são peças fundamentais para a proteção radiológica do paciente. Este estudo tem por objetivo caracterizar a composição elementar dos filtros de raios X de equipamentos de raios X odontológicos intrabucais. O estudo também relaciona a composição elementar com a qualidade das imagens radiográficas. A análise dos filtros foi realizada por meio do método de Espectroscopia de Fluorescência de raios X por Energia Dispersiva (EDXRF). Foram analisados, qualitativa e quantitativamente, dez filtros de alumínio. Para avaliar a qualidade das imagens, foram realizadas 30 radiografias periapicais dos dentes molares com 0,3 s de tempo de exposição (dez radiografias) e incisivos com 0,2 s e 0,3 s (vinte radiografias) com os diferentes filtros em um equipamento com os parâmetros de 66 kV e 6,5 mA. Os filtros e as radiografias foram identificadas, para que fosse possível distinguir a que filtro cada radiografia pertencia no momento das avaliações. Todas as radiografias foram feitas sob as mesmas condições. As radiografias foram submetidas à análise das densidades óticas por um densitômetro e posteriormente, enviadas a cirurgiões dentistas radiologistas que fizeram a análise subjetiva. Foram selecionadas três regiões para análise do densitômetro (diferenciadas entre dentes molares e incisivos) e uma região para análise subjetiva (diferentes regiões para dentes molares e incisivos). Os dados obtidos foram correlacionados com a avaliação dos efeitos da composição elementar dos filtros na qualidade das imagens radiográficas. Os elementos encontrados na análise dos filtros foram: Al, S, Cl, Ti, Mn, Fe, Cu, Zn e Zr. Os filtros apresentaram maiores concentrações de alumínio, com mais de 96% sendo os outros elementos contaminantes ou elementos que foram adicionados para melhorar a estabilidade mecânica do filtro. As densidades óticas das radiografias seguiram um padrão nas regiões analisadas, exceto as regiões enegrecidas do filme. A análise subjetiva revelou que muitas das radiografias realizadas poderiam ser aceitas para diagnóstico. Porém, imagens consideradas com baixo contraste obtiveram o mesmo valor de densidade ótica. Os resultados mostraram que a composição elementar dos filtros não modificou a qualidade da imagem. Por conseguinte, os filtros convencionais pesquisados oferecem uma opção aceitável para a produção de imagens de qualidade em radiologia odontológica, apesar das diferenças na composição das ligas. / The quest for radiographic quality with the lowest dose of radiation absorbed is a constant in the radiology community. Along with the ALARA principle (As Low As Reasonably Achievable), the aluminum filters are essential parts to bar the low energy photons do not contribute to the image and cause radiation dose to the patient. According to standard Portaria No. 453, the Agência Nacional de Vigilância Sanitária decreed that all equipment intraoral dental X-rays must have an additional filtration. Acording this, the filters are essential parts to radiological protection of patients. This study aims to characterize the elemental composition of filters used in intraoral X-ray equipment. We also intend to relate them to the quality of the radiographic images. The analysis of the filters was made using the method Energy Dispersive X-ray Fluorescence (EDXRF). Ten aluminum filters were analyzed (qualitatively and quantitatively). To evaluate the quality of images, 30 periapical radiographs of molars to 0.3 s (ten radiographs) and the incisor teeth 0.2 and 0.3 s (twenty radiographs) were performed with different filters. All filters and all radiographs were identified, it was possible to distinguish which folder each radiograph belonged at the time of the evaluations. All radiographs were performed under the same conditions. Radiographs were subjected to analysis of optical density by a densitometer and later, two dentists radiologists realized a subjective analysis. Three regions for analysis of the densitometer (differentiated between molars and incisors) and a region for subjective analysis (for different regions molars and incisors) were selected. The data were correlated with the assessment of the effects of the elemental composition of all filters in the quality of radiographic images. From the results, the elements of the filters in the analysis were: Al, S, Cl, Ti, Mn, Fe, Cu, Zn and Zr. The filters had higher aluminum concentrations (over 96%), other elements were contaminants or components that are added to improve the mechanical stability of the filter. The optical densities of radiographs followed a pattern for the regions analyzed except blackened regions of the film. Subjective analysis revealed that many of the radiographs were accepted for diagnosis. But considered low-contrast images obtained the same value of optical density. Therefore, it is concluded that the elemental composition of filters do not change the image quality. Consequently, conventional filters were evaluated option to produce an acceptable image quality in dental radiology, despite differences in the composition of the alloys.

Page generated in 0.0826 seconds