• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 155
  • Tagged with
  • 155
  • 116
  • 114
  • 101
  • 99
  • 99
  • 55
  • 49
  • 48
  • 48
  • 41
  • 39
  • 38
  • 37
  • 36
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Avaliação da termoestabilidade do surfactante de origem porcina desenvolvido pelo Instituto Butantan utilizando-se o modelo experimental do coelho prematuro / Stability analysis of a surfactant derived from porcine lungs administered to premature newborn rabbits

Paula Priscila Ohara Sakae 29 July 2008 (has links)
INTRODUÇÃO: A Síndrome do Desconforto Respiratório (SDR) é uma das principais causas de morbi-mortalidade no período neonatal, acometendo predominantemente os recém-nascidos prematuros, devido a uma está deficiência de surfactante pulmonar. O Instituto Butantan desenvolveu um surfactante de origem porcina com objetivo de torná-lo disponível a todo Sistema Único de Saúde. O objetivo deste estudo foi avaliar, em um modelo experimental de SDR (coelho), a estabilidade do Surfactante Butantan (SB) um ano após sua produção e armazenamento a 2 a 8ºC.. MÉTODOS: 94 coelhos prematuros foram randomizados em dois grupos de tratamento: grupo Butantan e grupo Curosurf (controle), e foram analisados em seis momentos de avaliação: momento zero (imediatamente após a retirada do refrigerador ao final de 1 ano de armazenamento), momento 1 (24 horas após ter sido mantido a 24ºC), momento 2 (após 30 dias de armazenamento a 20º C), momento 3 (após 60 dias de armazenamento a 20º C), momento 4 (após 90 dias de armazenamento a 20º C) e momento 5 (após 180 dias de armazenamento a 20º C). Após receberem o surfactante, os animais foram ventilados por 15 minutos para avaliação da pressão ventilatória e complacência pulmonar dinâmica e curva pressão-volume pulmonar, seguindo-se à avaliação histopatológica dos pulmões. RESULTADOS: A eficácia do SB foi semelhante à do Curosurf, um ano após a sua produção e armazenamento a 2 a 8ºC. Neste momento de avaliação, não houve diferença estatisticamente significante entre os grupos de estudo quanto a: pressão ventilatória, complacência pulmonar dinâmica e curva pressão-volume pulmonar. Ao longo dos seis meses de armazenamento inadequado do SB, demonstrou-se a redução de sua eficácia durante a fase expiratória da curva pressão-volume pulmonar. No entanto, a análise histopatológica, demonstrou não haver diferença significante entre os dois grupos de estudo em nenhum dos momentos de avaliação. CONCLUSÕES: As propriedades bioquímicas do SB foram preservadas após um ano de sua produção e armazenamento em refrigeração de 2 a 8ºC. Condições inadequadas de armazenamento resultam em alterações das propriedades bioquímicas do SB e, conseqüentemente, de sua função, o que foi demonstrado por parâmetros de mecânica ventilatória, mas não pela análise histopatológica dos pulmões / INTRODUCTION: Respiratory Distress Syndrome (RDS) is one of the major causes of death among premature newborns, and its development results from surfactant deficiency. The Butantan Institute has recently produced a porcine-derived surfactant preparation in order to make it available nationwide for RDS treatment in the near future. The aim of this study was to evaluate, in an animal model of surfactant deficiency (premature rabbits), the stability of the Butantan Surfactant (SB) one year after its production and storage in the refrigerator, at 2 to 8ºC. METHODS: 94 premature newborn rabbits were randomized into two treatment groups: SB or Curosurf®(control surfactant), and were assessed in six different time-points: time-point zero (immediately after removal of surfactant from the refrigerator after one year of storage); time-point 1 (after 24h of storage at 24ºC), time-point 2 (after 30 days of storage at 20ºC), time-point 3 (after 60 days of storage at 20ºC), time-point 4 (after 90 days of storage at 20ºC) and time-point 5 (after 180 days of storage at 20ºC). The animals were artificially ventilated for 15 minutes for lung mechanics assessment (ventilatory pressure, dynamic lung compliance and pressure-lung volume curve), followed by removal of the lungs for histopathologic analysis. RESULTS: After one year of its production and storage at 2 to 8ºC, SB was as efficient as Curosurf. At this time-point, The Butantan Surfactant showed no significant differences with Curosurf® regarding the ventilatory pressure, dynamic lung compliance and pressure-lung volume curve. Throughout the six month period of warming, SB showed a decreasing efficiency, as revealed by the expiratory phase of the pressure-lung volume curve. However, the histopathologic analysis revealed no significant differences between the two groups, in any of the study time-points. CONCLUSIONS: The Butantan Surfactant preserved its biochemical properties one year after its production and storage at 2 to 8ºC. On the other hand, adverse storing conditions can lead to alterations in the SB biochemical properties that result in deterioration of its function, which was demonstrated in this study by changes in lung mechanics, but not in the histopathologic analysis
92

Análise de polimorfismos do gene que codifica a proteína B do surfactante: comparação entre recém-nascidos pré-termo com e sem síndrome do desconforto respiratório / Surfactant protein B gene polymorphisms analysis: comparison between preterm newborns with and without respiratory distress syndrome

Priscila Pinheiro Ribeiro Lyra 01 July 2010 (has links)
A síndrome do desconforto respiratório (SDR) é causada pela deficiência transitória de surfactante pulmonar em recém-nascidos (RN) prematuros nos primeiros dias de vida. Estudos sugerem que a etiologia da SDR seja multifatorial e multigênica. A proteína B do surfactante (SP-B) é fundamental para o metabolismo do surfactante e para uma função pulmonar normal. A presença de polimorfismos e mutações em genes dos componentes do surfactante, particularmente no gene da SP-B, parece estar associada à SDR. Objetivos: Determinar a freqüência de polimorfismos do gene que codifica a proteína B do surfactante no DNA de recém nascidos pré-termo com e sem SDR, comparar as freqüências desses polimorfismos entre os dois grupos e avaliar se existe alguma relação entre sexo, raça e SDR. Casuística e Métodos: Foram incluídos no estudo 151 RNPT, sendo 79 sem SDR com idades gestacionais variando entre 29 semanas e 35 semanas e 6 dias e 72 RN pré-termo com SDR com idades gestacionais variando de 26 a 35 semanas. Foram analisados quatro polimorfismos: A/C no nucleotídeo - 18; C/T no nucleotídeo 1580; A/G no nucleotídeo 9306 e G/C no nucleotídeo 8714. Os polimorfismos foram determinados através da amplificação dos segmentos de DNA genômico por reação em cadeia da polimerase e posterior genotipagem. Os genótipos foram definidos através da análise dos produtos obtidos a partir de reações com enzimas de restrição [PCR-based converted restriction fragment length polymorphism (cRFLP)]. Resultados: O grupo Controle foi constituído por 79 RN pré-termo sem SDR; sendo 42 (53,2%) do sexo feminino e 37 (46,8%) do sexo masculino; 34 (43%) da raça negra, 16(20,3%) da raça branca e 29(36,7) de indivíduos pardos. O peso variou de 1170g a 3260 , e a idade gestacional variou de 29 semanas a 35 semanas e seis dias (média de 33 semanas e 6 dias).O grupo SDR foi composto por 72 RNPT, sendo que 31 (43%) do sexo feminino e 41 (57%) do sexo masculino; 31(43%) da raça negra, 16 (14%) da raça branca e 31(43%) de indivíduos pardos. O peso variou de 614g a 2.410g ; a idade gestacional média foi de 32 semanas , tendo variado de 26 semanas a 35 semanas. O modelo de regressão logística múltipla, utilizado para avaliar a contribuição das diversas variáveis na probabilidade de ocorrer SDR, demonstrou que a idade gestacional foi a variável que mais contribuiu para a ocorrência da patologia, e que o genótipo AG do polimorfismo A/G na posição 9306 foi um fator protetor para a doença nesta população (OR 0.1681; IC 95% 0.0426 - 0.6629). Não foram observadas diferenças entre as freqüências dos demais polimorfismos avaliados entre os 2 grupos de recém-nascidos, bem como diferenças quanto à raça e sexo. Conclusões: A presença do genótipo AG do polimorfismo A/G na posição 9306 do gene que codifica a proteína B do surfactante foi fator protetor para o desenvolvimento da síndrome do desconforto respiratório em recém-nascidos da cidade de Salvador-Bahia. Os polimorfismos A/C no nucleotídeo - 18, C/T no nucleotídeo 1580, e G/C no nucleotídeo 8714 presentes no referido gene não estiveram associados à síndrome do desconforto respiratório em recém-nascidos na amostra estudada. / The respiratory distress syndrome (RDS) is caused by surfactant transient deficiency in preterm babies soon after birht. Studies sugest that RDS etiology is multifactorial and multigenic. Surfactant protein B (SP-B) is essential for surfactant metabolism and fornormal lung function. Polymorphisms and mutations in the genes that encode the surfactant components, particularly the SP-B gene, have been associated to the pathogenesis of RDS. Aims: To analyze SP-B gene polimorfisms frequencies in preterm babies with RDS and healthy term newborns, to compare the polymorphisms frequencies between both groups and to evaluate if there are differences related to sex, race and RDS. Material and Methods: We included 151 neonates, 79 preterm babies without RDS and gestational ages ranging from 26 weeks to 35 weeks , and 72 preterm newborns with RDS, gestational ages ranging from 29 weeks to 35 weeks and 6 days. Four SP-B gene polymorphisms were analyzed: A/C at - 18, C/T at 1580; A/G at 9306 and G/C at nucleotide 8714. The polymorphisms were detected by PCR amplification of genomic DNA and genotyping. The genotypes were determined using PCR-based converted restriction fragment length polymorphism (cRFLP). Results: The control group comprised 79 preterm babies without RDS; 42(53,2%) were female and 37(46,8%) male; 34(43%) were black, 16(20,3) were Whites and 29(36.7%) non- Whites/non black. Weight ranged from 1.170g to 3.260g ; gestational age ranged from 29 weeks to 35 weeks and six days (mean 33 weeks and 6 days). The RDS group comprised 72 preterm neonates, 31(43%) female and 41(57%) male; 31(43%) were black, 16(14%) were Whites and 31(43%) non-Whites/non black. Weight ranged from 614g to 2.410g ; mean gestational age was 32 weeks (range, 26-35 weeks). The logistic regression model showed that gestational age was the variable that most contributed to the ocurrence of the respiratory distress syndrome and the AG genotype of the polymorphism A/G at 9306 was a protector factor for the disease in the studied population (OR 0.1681; CI 95% 0.0426 - 0.6629). We did not detect differences between the frequencies of the other evaluated polymorphisms between both groups of newborns. Conclusions: The presence of AG genotype at 9306 of the surfactant protein B (SP-B) gene was a protector factor for the development of the respiratory distress syndrome in newborns from the city of Salvador-Bahia. The polymorphisms A/C at nucleotide - 18, C/T at 1580, and G/C at nucleotide 8714 from the SP-B gene were not associated with respiratory distress syndrome in the studied population.
93

Estudo da incidência de lesão pulmonar aguda e síndrome do desconforto respiratório agudo nas unidades de terapia intensiva da região da Grande Vitória no Espírito Santo / Study of the incidence of acute lung injury and acute respiratory distress syndrome in the intensive care units in the region of Vitória in Espírito Santo

Eliana Bernadete Caser 21 February 2013 (has links)
INTRODUÇÃO: Existem muitas controvérsias, nos estudos epidemiológicos existentes, a respeito da incidência e desfechos da síndrome de lesão pulmonar aguda. A incidência e as características clínicas da síndrome dependem principalmente da definição utilizada e da metodologia empregada no estudo, bem como da disponibilização e utilização dos leitos nas unidades de terapia intensiva da região estudada. Pela ausência de dados epidemiológicos existentes de lesão pulmonar aguda na Grande Vitória, no Espírito Santo, realizamos este estudo para analisar a incidência, características, sobrevida aos 28 dias e mortalidade hospitalar. MÉTODOS: Os pacientes internados nas 14 unidades de terapia intensiva da Grande Vitória, durante o período de 15 meses, submetidos à ventilação mecânica e que preencheram os critérios de lesão pulmonar aguda da Conferência de Consenso Européia-Americana de 1994 foram selecionados prospectivamente para o estudo. Os pacientes também foram classificados de acordo com a nova definição de Berlim. Avaliamos as características clínicas e funcionais no primeiro dia de internação, durante a primeira semana, no 14º dia e no 28º dia de evolução. Foram calculadas a incidência da síndrome acumulada/ano, a sobrevida aos 28 dias e a mortalidade hospitalar. RESULTADOS: Foram avaliados 7.133 pacientes admitidos nas unidades de terapia intensiva, dos quais 130 (1,8%) foram selecionados. A mediana de tempo para o diagnóstico de lesão pulmonar aguda foi de 2 dias (IQ: 0-3 dias), sendo 25,4% dos diagnósticos realizados no momento da internação na unidade de terapia intensiva. Os fatores de risco foram principalmente pneumonia (35,3%), sepse não pulmonar (31,5%) e trauma (16,9%). A média de idade dos pacientes foi de 44,2 ± 15,9 anos, sendo 61,5% do sexo masculino. A média do APACHE II foi de 20,7 ± 7,9 e a média da PaO2/FiO2, de 206,7 ± 61,6. O tempo médio em ventilação mecânica foi de 21 ± 15 dias e o tempo médio de permanência na unidade de terapia intensiva foi de 26,4 ± 18,7 dias. De acordo com a nova definição de Berlim, os pacientes com a síndrome de desconforto respiratório agudo foram classificados em: leve, com 49 casos (37,7%); moderada, com 68(52,3%); e grave, com 13(10%). A incidência acumulada de LPA foi de 10,1 casos/100.000 habitantes/ano, sendo 3,8 casos/100.000 habitantes/ano para LPA sem SDRA e 6,3 casos/100.000 habitantes/ano para SDRA, representando 1,7% das admissões no ano. A relação PaO2/FiO2 nos dias 6 e 7 de evolução após o diagnóstico da síndrome foi um fator preditor independente para a mortalidade aos 28 dias, que foi de 38,5% (95% IC, 30,1-46,8). A mortalidade intrahospitalar foi de 49,2% (95% IC, 40,6-57,8), não diferindo entre os pacientes com LPA sem SDRA e SDRA. CONCLUSÕES: A incidência de LPA nos pacientes submetidos à ventilação mecânica invasiva na região da Grande Vitória, Espírito Santo, foi baixa, sendo a maioria dos casos diagnosticada 2 dias após a admissão nas unidades de terapia intensiva. A mortalidade aos 28 dias e a hospitalar dos pacientes com LPA sem SDRA e com SDRA não foram estatisticamente diferentes neste estudo. As mudanças nas práticas assistenciais nas unidades de terapia intensiva poderão contribuir para a redução da incidência da SDRA intrahospitalar / INTRODUCTION: There are many controversies in the existing epidemiological studies regarding the incidence and outcomes in acute lung injury. The incidence and clinical features of the syndrome mainly depend on the definition adopted and on the methodology employed in the study, as well as on the availability and use of beds in intensive therapy units in the regions studied. Due to the absence of existing epidemiological data concerning acute lung injury in Vitória, Espírito Santo, we conducted this study to analyze the incidence, clinical characteristics, survival rate at 28 days, and mortality rate. METHODS: The patients hospitalized in the 14 units of intensive therapy in the region of Grande Vitória for the period of 15 months submitted to mechanical ventilation, who fulfilled the criteria of acute lung injury as defined by the Conference of European-American Consensus of 1994, were prospectively selected for the study. These patients were also classified according to the new Berlin definition. We evaluated the clinical and functional characteristics on the first day of hospitalization, during the first week, on day 14 and on day 28 of clinical evolution. We calculated the cumulative incidence/year for the syndrome, the survival rate at 28 days, and hospital mortality. RESULTS: A total of 7,133 patients admitted to the intensive care units was evaluated, of whom 130 (1.8%) were selected. The median time to diagnosis of acute lung injury was 2 days (IQR: 0-3 days), 25.4% of diagnoses being made at admission to the intensive care unit. The risk factors were mainly pneumonia (35.3%), nonpulmonary sepsis (31.5%) and trauma (16.9%). The patients\' mean age was 44.2 ± 15.9 years, 61.5% being male. The APACHE II prognostic score averaged 20.7 ± 7.9, mean arterial oxygenation variable PaO2/FiO2 206 ± 61.6 and time on mechanical ventilation with a mean of 21 ± 15 days. The average length of stay in intensive care unit was 26.4 ± 18.7 days. Based on the new Berlin definition, patients with acute respiratory distress syndrome were classified as mild: 49 (37.7%); moderate: 68 (52.3%); and severe: 13 (10%). The cumulative incidence was 10.1 cases per 100,000 inhabitants /year for ALI, of which 3.8 cases per 100,000 inhabitants / year were for non-ARDS ALI and 6.3 cases per 100,000 inhabitants / year were for ARDS, representing 1.7% of admissions in the year. The variable arterial oxygenation on days 6 and 7 of evolution after the diagnosis of the syndrome was an independent factor for mortality at 28 days, which was 38.5% (95% CI, 30.1 to 46.8). In-hospital mortality was 49.2% (95% CI, 40.6 to 57.8), and did not differ between patients with ALI non-ARDS and acute respiratory distress syndrome Summary (ARDS). CONCLUSIONS: The incidence of acute lung injury in patients undergoing invasive mechanical ventilation in the region of Grande Vitória, Espírito Santo was low, most of them being diagnosed 2 days after admission to intensive care units. Mortality at 28 days and hospital mortality of patients with ALI non-ARDS were not statistically different in this study. Changes in care practices in intensive therapy units can contribute to reduce the incidence of in-hospital ARDS
94

Teste das microbolhas est?veis no aspirado bucal de rec?m-nascidos prematuros para o diagn?stico de s?ndrome do desconforto respirat?rio

Ribeiro, Manoel Antonio da Silva 08 July 2016 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2016-10-10T17:48:51Z No. of bitstreams: 1 TES_MANOEL_ANTONIO_DA_SILVA_RIBEIRO_PARCIAL.pdf: 688919 bytes, checksum: 8a56a70e578bd3446bdbd3b5c916e884 (MD5) / Made available in DSpace on 2016-10-10T17:48:51Z (GMT). No. of bitstreams: 1 TES_MANOEL_ANTONIO_DA_SILVA_RIBEIRO_PARCIAL.pdf: 688919 bytes, checksum: 8a56a70e578bd3446bdbd3b5c916e884 (MD5) Previous issue date: 2016-07-08 / BACKGROUND: The stable microbubbles test on the gastric aspirate has been used for the diagnosis of respiratory distress syndrome of the newborn. However, its use in the preterm newborn oral aspirate was not determined. OBJECTIVE: To evaluate the performance of the stable microbubbles test done on oral aspirate from preterm newborns to predict of respiratory distress syndrome. METHOD: In the study were included infants with gestational age < 34 weeks. Oral secretion sample was obtained immediately after birth and gastric secretion was collected within 30 minutes of life. The samples were frozen and tested within 72 hours. RESULTS: The sample was composed of paired secretion of 70 newborns. The median (interquartile range) of the stable microbubbles count in the oral samples of infants with respiratory distress syndrome was significantly lower than those who did not develop or had respiratory symptoms from other causes: 12 (8 - 22) versus 100 (48 - 230) versus 70 (44 - 208) (p <0.01). The correlation between microbubble count in gastric and bucal aspirates was 0.88 (95%CI: 0,72 ? 0,93; p <0.01). Taking a cut-off point of 15 microbubbles/mm2, the sensitivity of test was 95.4%, the specificity 66.7%, and the agreement of the oral fluid with the gastric fluid was 0.76. CONCLUSION: The study suggests that the stable microbubbles test in gastric aspirate made at birth is a reliable alternative to the gastric fluid in the prediction of respiratory distress syndrome of the newborn. / INTRODU??O: O teste das microbolhas est?veis no aspirado g?strico tem sido utilizado para o diagn?stico de s?ndrome do desconforto respirat?rio do rec?m-nascido. Entretanto, a sua utiliza??o no fluido bucal em rec?m-nascidos pr?-termo ainda n?o foi avaliada. OBJETIVO: Avaliar o desempenho do teste das microbolhas est?veis no aspirado bucal de neonatos pr?-termo para a predi??o da s?ndrome do desconforto respirat?rio. M?TODO: Foram inclu?dos no estudo, rec?m-nascidos com menos de 34 semanas de idade gestacional. A secre??o bucal foi obtida imediatamente ap?s o nascimento e a secre??o g?strica at? 30 minutos de vida. As amostras foram congeladas e testadas em at? 72 horas. RESULTADOS: A amostra foi constitu?da de secre??o pareada de 70 rec?m-nascidos. A mediana (amplitude interquartil) da contagem das microbolhas est?veis no fluido bucal dos rec?m-nascidos com s?ndrome do desconforto respirat?rio foi significativamente menor do que os que n?o desenvolveram ou dos tiveram sintomas respirat?rios por causas indeterminadas: 12 (8-22) versus 100 (48 - 230) versus 70 (44 - 208) (p<0,01), respectivamente. A correla??o entre o teste das microbolhas nos aspirados g?strico e bucal foi 0,88 (IC95%: 0,72 ? 0,93; p <0.01). O melhor ponto de corte para predizer a s?ndrome do desconforto respirat?rio foi 15 microbolhas/ mm2, apresentando sensibilidade de 95,4%, especificidade de 66,7% e concord?ncia com o aspirado g?strico de 0,76. CONCLUS?O: O estudo sugere que o teste das microbolhas est?veis no aspirado bucal ao nascimento ? uma alternativa confi?vel ao fluido g?strico na predi??o da s?ndrome do desconforto respirat?rio do rec?m-nascido.
95

Efeito da ventilação não invasiva com pressão positiva contínua nas vias aéreas de pacientes oncológicos / Effects of noninvasive ventilation with continuous positive pressure on the airways of oncologic patients

Manfrim, Gabriela Marcon 26 September 2008 (has links)
INTRODUÇÃO: A insuficiência respiratória acomete grande parte dos pacientes oncológicos levando a altos índices de mortalidade. A ventilação não invasiva (VNI) pode auxiliar seu manejo, mas seus efeitos ainda são pouco conhecidos sobre os mecanismos de defesa pulmonar. OBJETIVOS: Observar o efeito da VNI com máscara facial usando-se geradores de fluxo com pressão positiva contínua (CPAP) e ventilador microprocessado no modo pressão de suporte + pressão positiva ao final da expiração (PSV + PEEP), a fim de verificar impacto nas propriedades viscoelásticas do muco respiratório e o conforto proporcionado ao paciente. MÉTODOS: A VNI foi instalada após diagnóstico de insuficiência respiratória em dezenove pacientes, admitidos nas unidades de tratamento intensivo do Hospital A. C. Camargo, sendo nove submetidos ao CPAP e dez com PSV + PEEP. Foram colhidos antes e após uma hora de VNI: os dados clínicos, secreção nasal, gasometria, e o grau de conforto através de uma escala visual. As propriedades físicas do muco (transportabilidade in vitro, adesividade e wettabilidade ou hidrofobicidade) foram avaliadas respectivamente no palato de rã, máquina da tosse e ângulo de contato. RESULTADOS: Os grupos eram homogêneos entre si em relação à idade, sexo, tipo e estadiamento do tumor e SAPS II. Em relação às propriedades físicas do muco, houve um aumento da transportabilidade in vitro do muco nasal com o sistema PSV + PEEP (p = 0,04) e um aumento na wettabilidade no grupo CPAP (p = 0,06). Os dois sistemas foram eficazes em melhorar significativamente os sinais vitais, a PaO2/FiO2, o padrão e o conforto respiratório e em evitar a intubação traqueal nas primeiras 24 horas (p < 0,05). Entretanto, independentemente do tipo de sistema de VNI usado, foram encontrados altos índices de intubação endotraqueal e mortalidade no seguimento destes pacientes. CONCLUSÃO: As propriedades físicas do muco (transportabilidade in vitro e wettabilidade) se alteraram após uma hora de uso da VNI e parecem ser dependentes da temperatura e umidificação dentro da máscara. A VNI mostrou-se útil em reverter a insuficiência respiratória em pacientes selecionados, ou pelo menos em trazer conforto para pacientes hipoxêmicos que a princípio recusam a intubação endotraqueal / INTRODUCTION: Respiratory failure is a common situation among cancer patients leading to high rates of mortality. Noninvasive ventilation (NIV) can help its management, but its effects are still unknown regarding the pulmonary defense mechanisms. OBJECTIVES: Observe the effect of NIV with facial mask using a flow generator with continuous positive pressure (CPAP) and standard intensive care unit ventilator using pressure support ventilation + positive end expiratory pressure (PSV + PEEP), to verify impact on the physical properties of respiratory mucus and the comfort provided to the patient. METHODS: NIV was started after diagnosis of respiratory failure in nineteen patients, admitted in the intensive care unit of the A. C. Camargo Hospital. Nine patients were submitted to CPAP and ten to PSV + PEEP. Nasal mucus, blood gases, and the degree of comfort through a visual scale were accessed before and after one hour. The physical properties of nasal mucus (transportabilility in vitro, adhesivity and wettability or hydrofobicity) were evaluated respectively by frog palate, cough machine and contact angle. RESULTS: Groups had similar characteristics about age, sex, tumor and SAPS II score. Regarding the physical properties of the mucus, there was an increase in mucus transportability (by the frog palate model) with the system PSV + PEEP (p = 0.04) and an increase in the contact angle in the CPAP groupo (p = 0.06). The two systems were effective in improving the vital signs, the PaO2/FiO2, the respiratory pattern and comfort and avoiding endotracheal intubation in the first 24 hours (p < 0.05). However, regardless of the type of NIV system used, high rates of endotracheal intubation and mortality were found. CONCLUSION: The physical properties of the mucus (transportability in vitro and wettability) changed after an hour of use of the NIV as a result of temperature and humidification into the mask. NIV was useful in reversing the respiratory failure in selected patients, or at least in bringing comfort for those who refuse endotracheal intubation
96

Sobredentaduras mandibulares retidas por mini implantes: um ensaio clínico randomizado (parte I) / Mandibular overdentures retained by conventional or mini implants: a randomized clinical trial (parte I)

Ribeiro, Adriana Barbosa 13 January 2015 (has links)
A retenção de próteses totais removíveis por mini-implantes é uma modalidade de tratamento relativamente recente, com potencial de minimizar o trauma pós-operatório e reduzir custos associados. Este estudo buscou comparar a qualidade de vida relacionada à saúde bucal e satisfacão do paciente, bem como dor e desconforto pós-operatórios, decorrentes da instalação de mini-implantes (dois ou quatro) ou dois implantes de dimensões regulares para a retenção de sobredentaduras mandibulares. Cento e vinte participantes edentados (media etária 59,5±8,5 anos) foram alocados aleatoriamenteem três grupos conforme o tratamento recebido: (GI) quatro mini-implantes, (GII) dois mini-implantes, ou (GIII) dois implantes regulares. Sete dias após a instalação dos implantes, os participantes responderam questões (Escala visualanalógica - EVA de 100 mm) referentes à dor, edema e desconforto durante mastigação, fala e higiene, considerando as experiências vividas durante os períodos avaliados. Antes das intervenções e passados 3 e 6 meses da instalação das sobredentaduras, a qyalidade de vida relacionada à saúde bucal foi avaliada por meio do questionário OHIP-EDENT, e a satisfação analisada por perguntas específicas respondidas emu ma EVA de 100 mm. Os grupos foram comparados por meio de ANOVA para dois fatores ou Equações de Estimação Generalizadas (EEG) (&alpha;=0,05). Todos os participantes (GI: 38; GII: 42; GIII: 40) foram analisados após sete dias da instalação dos implantes instalação para dor e desconforto pós-operatório, e 112 responderam às questões sobre qualidade de vida relacionada à saúde bucal e satisfação de paciente. Ao 6º dia, GI sentiu dor significantemente maior que GII e GIII. GI também notou maior dificuldade para a prática de higiene oral que GIII durante o 1º dia. Não houve diferença significante entre os grupos para outras questões e períodos. Os achados para o OHIP-EDENT indicam que tanto os grupos tratados com dois ou quatro mini-implantes levaram a uma maior QVSB, comparados aos implantes convencionais. Aos três e seis meses, encontramos que os três grupos tratados com quatro mini-implantes estavam mais satisfeitos que os que receberam dois implantes convencionais e dois mini-implantes resultaram em valores intermediários. Conclui-se que o uso de quatro mini-implantes induz maior dor pós-operatória ao sexto dia que a inserção de dois mini-implante ou implantes convencionais, bem como higiene oral mais difícil ao primeiro dia. Além disso, o tratamento com sobredentaduras retidas por mini-implantes é comparável ao padrão de tratamento para o edentulismo, de acordo com as perspectivas do paciente. O tratamento por dois ou quatro mini-implantes alcança resultados similares ou mesmo discretamente superiores em termos de qualidade de vida relacionada à saúde bucal ou satisfação do paciente, comparado aos implantes convencionais / The retention of removable dentures by mini-implants is a relatively recent treatment modality, and may lead to minimal postoperative trauma and reduced costs. This study aimed to compare oral health-related quality of life and patient satisfaction, as well as postoperative pain and discomfort, following the insertion of mini-implants (two or four) or two standard-size implants for the retention of mandibular overdentures. One hundred and twenty edentulous participants (mean age 59.5±8.5 years) were randomly allocated into three groups according to received treatment: (GI) four mini-implants, (GII) two mini-implants, or (GIII) two standard implants. Seven days after implant insertion, patients answered questions (100-mm VAS Visual Analog Scale) relating to pain, swelling, and discomfort with chewing, speech and hygiene, considering their experiences during the 1st and 6th day. Before the interventions and after 3 and 6 months following insertion, OHRQoL was evaluated by means of the OHIP-EDENT questionnaire and patient satisfaction was analyzed by a specific questionnaire answered on a 100-mm VAS. Groups were compared by two-way ANOVA or Generalized Estimating Equations (GEE) (&alpha;=0.05). All participants (GI: 38; GII: 42; GIII: 40) were analyzed after seven days of postoperative pain and discomfort, and 112 answered questions regarding oral health-related quality of life and patient satisfaction. At the 6th day, GI felt significantly higher pain than GII and GIII. GI also reported more difficulty in performing oral hygiene practices than GIII during the 1st day. There was no significant difference between groups for the other questions and periods. The findings from OHIP-EDENT indicate that both two and four mini-implants led to better OHRQoL, compared to two conventional implants. At three and six months, we found that the group treated with four mini-implants was more satisfied than the two conventional implants and two mini-implants was presented intermediate values. It can be concluded that the use of four mini-implants induces more intense postoperative pain at the 6th day than the insertion of two mini- or conventional fixtures, as well as more difficult oral hygiene on the 1st day. Furthermore, the treatment by mini-implant overdentures is comparable to the standard of care for edentulism, according to the patient perspective. Treatment by either two or four mini-implants achieve similar or even slightly better OHQoL and satisfaction compared to two conventional implants
97

Percepção de desconforto no uso de brincos : relação das característica sociodemográficas, morfoantropométricas, dos hábitos relacionados ao uso e da preferência quanto ao tipo de produto / Earring discomfort perception: relationship between social demographic, morpho anthropometric characteristics and product type preferences and habits of wearing earrings

Strobel, Elisa 30 July 2014 (has links)
Made available in DSpace on 2016-12-12T20:17:55Z (GMT). No. of bitstreams: 1 118604.pdf: 5890822 bytes, checksum: d70b354d67e20081b2cad602742a22c8 (MD5) Previous issue date: 2014-07-30 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Surveying sociodemographic, morpho-anthropometric characteristics in women, related to their habits and product preferences wearing earrings, aiming to verify the relationship of these domains with the perception of discomfort. Discomfort was assessed using descriptors. The earlobe thickness and earring dimensions used by the participant on the day of data collection were measured with a digital micrometer, universal caliper and a digital scale. The ear and earlobe shape and the earring hole were classified according to the literature. 208 adult women, were surveyed separated by age groups. Parametric data are presented as mean and standard deviation and non-parametric as frequency distributions. The correlations between the variables were then verified. 80.3% women answered that they wear earrings on a daily-basis and all individuals reported some degree of discomfort, from slight (13.6%), to moderate (26.9%) or severe (59.1%). The average earlobe thickness was 5.80 ± 0.83 mm (left). 58% of the lobules were classified as dettached, and 42% as attached (left). The most widely used type of earring was the stud type, followed by the dangling type and at last the hoop. 77.7% wore earrings that weighed between 0.1 g to 2.5 g on the day of data collection. We conclude that for this sample, the discomfort in the use of earrings is mainly related to product characteristics. The mass and then the material were more associated with discomfort in the use of earrings. Ergonomic recommendations and opportunities for improvement are then presented. / O objetivo deste estudo foi avaliar a relação das características sociodemográficas, morfoantropométricas, dos hábitos relacionados ao uso e da preferência quanto ao tipo de produto com a percepção de desconforto no uso de brincos em mulheres. O desconforto foi avaliado por meio de descritores. A espessura dos lóbulos, e dimensões do brinco utilizado pela participante na data da coleta foram medidos com mícrômetro digital, paquímetro universal e balança digital. A forma geral da orelha externa, do lóbulo e o furo foram aferidos de acordo com a literatura. Foram pesquisadas 208 mulheres maiores de idade, separadas por faixa etária. Os dados paramétricos foram descritos por média e desvio padrão, os não-paramétricos por distribuições de frequências. Foram ainda testadas as correlações entre as variáveis. 80,3% da amostra usa brincos todos os dias e todos os indivíduos se enquadraram em algum nível de desconforto leve (13,6%), moderado (26,9%) ou grave (59,1%). A média da espessura do lóbulo foi 5,80±0,83mm (esquerdo). 58% dos lóbulos foi aferida como solto, e 42% como preso (esquerdo). O tipo de brinco mais usado foi o inteiro, seguido do pêndulo e argola. 77,7% usava brincos que pesavam entre 0,1g a 2,5g na data da coleta. Conclui-se que para esta amostra, as questões quanto ao desconforto no uso de brincos são principalmente relacionados às características do produto. A massa do brinco seguida do material foram os aspectos mais associadas ao desconforto no uso de brincos. Por fim são apresentadas recomendações ergonômicas e oportunidades de melhoria.
98

Comparação entre posição prona e posição supina, associadas à ventilação oscilatória de alta frequência e ventilação mecânica convencional protetora, em modelo experimental de lesão pulmonar aguda

Pires, Rafaelle Batistella. January 2018 (has links)
Orientador: José Roberto Fioretto / Resumo: A Síndrome do Desconforto Respiratório Agudo (SDRA) cursa com alta morbi-mortalidade apesar dos avanços no entendimento de sua fisiopatologia e tratamento. A terapia ventilatória baseia-se na proteção pulmonar, sendo a ventilação oscilatória de alta frequência (VOAF) uma opção de método protetor. A posição prona (PP) é terapia adjuvante que possibilita homogeneização da distribuição do volume corrente (VC) e promove recrutamento alveolar. O objetivo do estudo foi investigar o efeito da posição prona associada à VOAF e ventilação mecânica convencional (VMC) protetora sobre a oxigenação, inflamação, dano oxidativo e histologia pulmonares, comparando-a à posição supina em ambos os modos ventilatórios. Foram instrumentados 75 coelhos com traqueostomia e acessos vasculares. A lesão pulmonar aguda (LPA) foi induzida por lavagem traqueal de salina aquecida (30mL/Kg, 38°C). Os animais foram então aleatorizados em cinco grupos (n=15): 1) GC (Controle): animais sadios em VMC protetora basal; 2) GVMS: animais com LPA em VMC protetora e posição supina; 3) GVMP: animais com LPA em VMC protetora e posição prona; 4) GVAFS: animais com LPA em VOAF e posição supina; 5) GVAFP: animais com LPA em VOAF e posição prona. Após, foram submetidos a quatro horas de VMC protetora (modo pressão regulada-volume controlado, PEEP 10 cmH2O, VC 6mL/kg, Ti 0,5s, FR 40 rpm e FiO2 1) ou VOAF (MAP 15 mmHg, FR 10Hz, amplitude 22 e FiO2 1). O nível de significância foi de 5%. Após a indução, os grupos apresentaram... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Acute Respiratory Distress Syndrome (ARDS) presents with high morbidity and mortality despite advances in the understanding of its pathophysiology and treatment. Ventilatory therapy is based on the intention of injuring less, with high frequency oscillatory ventilation (HFOV) being a protective method option. Prone position (PP) is an adjuvant therapy that enables homogenization of volume tidal (VT) distribution and promotes alveolar recruitment. The aim of this study was to investigate the effects of prone position associated with HFOV and protective conventional mechanical ventilation (CMV) on oxygenation and lung inflammation, oxidative damage and histology, comparing it with the supine position in both ventilatory modes. Seventy five rabbits were submitted to tracheostomy and vascular accesses. ALI was induced by tracheal infusion of heated saline (30mL/kg, 38° C). The subjects were then ramdomized in five groups (n=15): 1) CG (Control): healthy animals in basal protective CMV; 2) MVSG: animals with ALI in protective CMV and supine position; 3) MVPG animals with ALI in protective CMV and prone position; 4) HFSG: animals with ALI in HFOV and supine position; 5) HFPG: animals with ALI in HFOV and prone position. After that, they were submitted to four hours of protective VMC (PRV mode, PEEP 10 cmH2O, VC 6ml/kg, Ti 0,5s, FR=40 rpm and FiO2 1) or HFOV (MAP 15 mmHg, FR 10 Hz, amplitude 22 and FiO2 1). The level of significance was 5%. After induction, the groups presented simi... (Complete abstract click electronic access below) / Doutor
99

Ingestão de bicarbonato de sódio e cloreto de amônio e seus efeitos sobre o ritmo de prova, desempenho e equilíbrio ácido-base em um teste contrarrelógio de ciclismo de 4km / Sodium bicarbonate and ammonium chloride ingestion and their effects on pacing, performance and acid-base balance during a 4-km cycling time trial

Carlos Rafaell Correia de Oliveira 09 June 2016 (has links)
Nós determinamos a influência da alcalose e acidose metabólica induzida sobre o ritmo de prova, gasto energético e desempenho durante um teste contrarrelógio de ciclismo de 4 km (TCR). Após um estudo preliminar (N=7) determinando as doses ótimas de cloreto de amônio (NH4Cl), bicarbonato de sódio (NaHCO3) e placebo (carbonato de cálcio, CaCO3), 11 ciclistas amadores realizaram um TCR de 4 km 100 min após ingerirem 0,15 g·kg-1 de NH4Cl, 0,3 g·kg-1 de NaHCO3 ou 0,15 g·kg-1 de CaCO3 (desenho de medidas repetidas, contrabalançado e duplo-cego). Comparado com placebo, a ingestão de NaHCO3 resultou em uma alcalose sanguínea pré-exercício (pH: + 0,06 ± 0,04, [HCO3-]: + 4,7 ± 2,6 mmol?L-1, excess de base: + 4,6 ± 2,4 mmol?L-1, P<0,05), enquanto que o NH4Cl resultou em uma acidose sanguínea (pH: - 0,05 ± 0,04, [HCO3-]: - 5,5 ± 2,9 mmol?L-1, excesso de base: - 5,3 ± 2,5 mmol?L-1, P<0.05), com essas diferenças permanecendo durante todo o teste. Apesar de nenhum desconforto gastrointestinal severo, os participantes adotaram um ritmo de prova significativamente mais conservador em NH4Cl comparado com placebo e NaHCO3, que foi acompanhado por uma redução na taxa de gasto energético anaeróbio (~ -14 %, P<0,05) e menor trabalho anaeróbio total (~ -13 %, P<0,05). Consequentemente, o desempenho foi prejudicado em NH4Cl (~ -7 %) comparado com as demais condições (P<0,05). O lactato plasmático, VCO2 e a PetCO2 foram menores e a VE/VCO2 maior durante o TCR em acidose do que em placebo e alcalose (P<0,05). Entretanto, não houve diferença para essas variáveis entre placebo e NaHCO3 (P<0,05). A acidose metabólica induzida diminuiu o ritmo de prova e o metabolismo anaeróbio, além de prejudicar o desempenho durante um TCR de 4 km, independente de desconforto gastrointestinal / We determined the influence of induced metabolic alkalosis and metabolic acidosis on pacing, energy expenditure and performance during a 4-km cycling time trial (TT). After a preliminary study (N=7) determining the optimal ammonium chloride (NH4Cl), sodium bicarbonate (NaHCO3), and placebo (calcium carbonate, CaCO3) doses, 11 amateur cyclists performed a 4-km TT 100 min after ingesting either 0.15 g·kg-1 of body mass of NH4Cl, 0.3 g·kg-1 of NaHCO3 or 0.15 g·kg-1 of CaCO3 (double-blind, counterbalanced and repeated-measures design). Compared with placebo, the NaHCO3 ingestion resulted in a pre exercise blood alkalosis (pH: +0.06 ± 0.04, [HCO3-]: +4.7 ± 2.6 mmol?L-1, base excess: +4.6 ± 2.4 mmol?L-1, P<0.05), while NH4Cl resulted in a blood acidosis (pH: -0.05 ± 0.04, [HCO3-]: -5.5 ± 2.9 mmol?L-1, base excess: -5.3 ± 2.5 mmol?L-1, P<0.05), with these differences remaining throughout the trial. Despite no gastrointestinal distress, participants adopted a significant more conservative pacing in NH4Cl compared with placebo and NaHCO3, which was accompanied by a reduced anaerobic energy expenditure rate (~ -14 %, P<0.05) and lower total anaerobic work (~ -13 %, P<0.05). Consequently, the performance was less in NH4Cl (~ -7 %) compared with other conditions (P<0.05). Plasma lactate, VCO2 and PetCO2 were lower and the VE/VCO2 higher during the TT in acidosis than in placebo and alkalosis (P<0.05). However, there was no difference for these variables between placebo and NaHCO3 (P>0.05). Induced metabolic acidosis slows pacing, decreases anaerobic metabolism and impairs performance during a 4-km TT, independent of gastrointestinal distress
100

Estudo do campo térmico: o caso do Campus IV - UFPB

Melo, Beatriz Cristina Barbalho de 30 September 2015 (has links)
Submitted by Maike Costa (maiksebas@gmail.com) on 2017-06-09T13:53:11Z No. of bitstreams: 1 arquivototal.pdf: 6611581 bytes, checksum: c211426580c5968c831b220686a8f8f8 (MD5) / Made available in DSpace on 2017-06-09T13:53:11Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 6611581 bytes, checksum: c211426580c5968c831b220686a8f8f8 (MD5) Previous issue date: 2015-09-30 / The microclimate consequences of a particular place to demonstrate that he as urban growth and exploitation of natural resources are increasing unfortunately. The weather is the most important component in maintaining the ecological balance. And his study becomes complex due to the various facets that involve him, turning indispensable interdisciplinary study, it could help in the reduction and / or more efficient solution of the urban problems. Studies of this order become relevant to planning and environmental management, which arouses interest for research on the thermal field of urban areas. The problem of this research is related to concern about anthropogenic implications on the local microclimate. It is known that human actions on the microclimate and the lack of proper planning of a particular place, can contribute to the thermal discomfort of users and demand higher energy costs. The present search, has as main objective to analyze the field thermal the Campus IVUFPB, located in the city of Rio Tinto-PB. In this case, seeks if relate the anthropogenic actions with the main thermal problems, detected on site. To obtain microclimate data, were installed in similar (which takes into account the type of soil cover, in this case, coating in cementitious composition) points, measuring equipment, in six points within the campus IV- UFPB, in dry season (from March 04 to April 7, 2015) and during the rainy season (from 09 June to 13 July 2015), totalizing 35 days in each measurement period. From the analysis and management of the data obtained, the presence of heat islands was detected within the study area as well as the rise in temperature in places with low circulation of winds and decreased moisture and the low individuals presence of arboreal. The results allowed the elaboration of suggestions with proposed thermal environmental, as; the ceramic roof replacement, in the hottest areas for green cover; replacing paving stones and interlocked block, per tread grass, that provide the minimization of thermal effects identified in the Campus IV-UFPB. With this, this research, can to corroborate to reveal the adverse effects of the anthropogenic actions that provoke microclimatic modifications in the thermal field of Campus IV-UFPB, making a relation with its urban components. / As consequências microclimáticas de um determinado local demonstram o quão desastrosamente o crescimento urbano e a exploração dos recursos naturais vêm aumentando. O clima é o componente mais importante na manutenção do equilíbrio ecológico. E seu estudo se torna complexo devido às diversas facetas que o envolvem, tornando imprescindível o estudo interdisciplinar que pode auxiliar, na diminuição e/ou solução mais eficiente das problemáticas do meio urbano. Estudos dessa ordem se tornam relevantes para o ordenamento e a gestão ambiental, o que desperta interesse para pesquisas sobre o campo térmico de áreas urbanas. A problemática desta pesquisa está relacionada com a preocupação sobre as implicações antrópicas sobre o microclima local. Sabe-se que as ações antrópicas sobre o microclima e a falta de planejamento adequado de um determinado local, podem contribuir para o desconforto térmico dos usuários e demandar maiores custos energéticos. A presente pesquisa tem como objetivo geral analisar o campo térmico do Campus IV-UFPB, localizado na cidade de Rio Tinto-PB. Nesse caso procura-se relacionar as ações antropogênicas com as principais problemáticas térmicas, detectadas no local. Para a obtenção de dados microclimáticos, foram instalados, em pontos semelhantes (que levam em consideração o tipo de recobrimento do solo, neste caso, revestimento de composição cimentícia), equipamentos de medição, em seis pontos dentro do campus IV-UFPB, no período seco (de 04 de Março a 07 de Abril de 2015) e no período chuvoso (de 09 de Junho a 13 de Julho de 2015), somando-se 35 dias em cada período de medição. A partir da análise e ordenamento dos dados coletados, ficou constatada a presença de ilhas de calor dentro da área de estudo, bem como o aumento de temperatura em locais com pouca circulação dos ventos e a diminuição da umidade em locais com pouca presença de indivíduos arbóreos. A análise dos resultados permitiu elaborar sugestões com propostas termo ambientais do tipo, substituição de telhado cerâmico, nas áreas mais quentes, por telhado verde extensivo; a substituição de paralelepípedos e blocos intertravados, por piso grama que proporcionem a minimização dos efeitos térmicos identificados, no Campus IV-UFPB. Com isso, esta pesquisa, pode vir a corroborar no desvendar dos efeitos adversos das ações antropogênicas, que provocam alterações microclimáticas no campo térmico do Campus IV-UFPB, fazendo uma relação com seus componentes urbanos.

Page generated in 0.0557 seconds