Spelling suggestions: "subject:"disability evaluation"" "subject:"isability evaluation""
71 |
Qualidade de vida e capacidade funcional em idosos com dor lombar cronicaFalcão, Fabiana Conceição de Oliveira Santos 28 June 2006 (has links)
Orientador: Maria Jose D'Elboux Diogo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Educação / Made available in DSpace on 2018-08-06T22:25:47Z (GMT). No. of bitstreams: 1
Falcao_FabianaConceicaodeOliveiraSantos_M.pdf: 1241878 bytes, checksum: 98a929778d4ecdf11274945217f53e3f (MD5)
Previous issue date: 2006 / Resumo: Este estudo teve como objetivo geral investigar a qualidade de vida relacionada à saúde (QVRS) e incapacidade em idosos com dor lombar crônica. Fizeram parte deste estudo 92 idosos com dor lombar crônica atendidos em um centro de reabilitação. Os dados foram obtidos por meio da aplicação dos instrumentos de caracterização sociodemográfica e clínica; de avaliação da QVRS ¿ Medical Outcomes Study 36-item short-form healthy survey (SF-36); Brasil ROLAND-MORRIS (Brasil-RM) para avaliação da incapacidade; Escala Qualitativa de Dor (EQD) e Escala de Depressão Geriátrica (EDG-15). Foram realizadas as seguintes análises: descritiva; coeficientes de confiabilidade; análise de variância univariada (ANOVA) e multivariada (MANOVA); coeficientes de correlação de Pearson (r) e Sperman (rs); análise de regressão linear univariada e múltipla (stepwise); e Teste de Mann-Whitney. De acordo com a ANOVA, as variáveis que influenciaram diferentes dimensões do SF-36 foram: sexo, escolaridade, distúrbios do sono, duração do episódio atual da dor lombar, intensidade da dor e sintomas depressivos. Enquanto que na MANOVA somente as variáveis intensidade da dor e sintomas depressivos afetaram a QVRS dos idosos como um todo. As variáveis que tiveram significância na análise de regressão univariada foram faixa de idade, presença de distúrbios do sono, atividade física, duração do episódio atual há mais de um ano, parestesia, fraqueza muscular, rigidez matinal, intensidade da dor e sintomas depressivos. Destas variáveis as que juntas explicaram 36,5% da variabilidade dos escores do Brasil-RM, na análise de regressão múltipla foram: intensidade da dor; rigidez matinal; distúrbios do sono e sintomas depressivos. Houve correlação negativa significante de forte magnitude entre as dimensões capacidade funcional, aspectos físicos, aspecto emocional e Brasil-RM; estado geral de saúde, vitalidade, aspecto emocional, saúde mental e sintomas depressivos. Os resultados evidenciam que a QVRS e a incapacidade funcional dos idosos com dor lombar crônica estão correlacionados e são influenciados, principalmente, pela intensidade da dor e sintomas depressivos. Portanto, recomenda-se que sejam elaboradas intervenções voltadas para minimizar a dor lombar referida por estes idosos, bem como melhorar as outras variáveis relacionadas ao aumento da dor lombar destes sujeitos, visando otimizar a capacidade funcional e, conseqüentemente, a QVRS / Abstract: This study had the objective to investigate the health related quality of life (HRQL), and disabilities in elderly people with chronic low back pain. The participants were 92 elderly people with chronic low back pain who attended a rehabilitation center. The data were gathered through the administration of sociodemographic and clinical outcome measures; the evaluation of HRQL ¿ The Medical Outcomes Study 36-item short-form healthy survey (SF-36); Brazil ROLAND-MORRIS (Brazil-RM) for the evaluation of the disabilities; numerical pain rating scale (PS) and Geriatric Depression Scale (GDS). The following analyses were made: descriptive; coefficients of reliability; univariate (ANOVA) and multivariate (MANOVA); Pearson¿s correlation and Spearman¿s correlation coefficients; univariate and stepwise linear multiple regression analysis; and the Mann-Whitney test. According to ANOVA, the variables which influenced different dimensions of SF-36 were: gender, level of education, sleep disorders, duration of the current episode of low back pain, intensity of pain, and depressive symptoms. While in MANOVA only the variables intensity of pain and depressive symptoms affected the HRQL of the elderly people as a whole. The variables which were significant in univariate linear regression were age range, presence of sleep disorders, physical activity, duration of the current episode for more than one year, paresthesia, muscle weakness, morning stiffness, intensity of pain and depressive symptoms. The variables which explained 36.5% of the score variability of Brazil-RM, in the stepwise multiple linear regression were: intensity of pain; morning stiffness; sleep disorders and depressive symptoms. There was a significant negative correlation of high magnitude among the dimensions physical functioning, role-physical, role-emotional and Brazil-RM; general health, vitality, role-emotional, mental health and depressive symptoms. The correlation among Brazil-RM and intensity of pain and depressive symptoms, although significant, has a moderate magnitude. The results make evident that HRQL and the disabilities of the elderly people with chronic low back pain are correlated and are influenced mainly by intensity of pain and depressive symptoms. Therefore, it is recommended to elaborate interventions oriented to minimize the low back pain referred by these elderly people, as well as to improve the other variables related with the increasing of the low back pain of these subjects, aiming the optimization of functional capability and hence, the HRQL / Mestrado / Mestre em Gerontologia
|
72 |
Posturografia dinâmica e tempo de marcha: marcadores de declínio funcional em pacientes com esclerose múltipla e leve incapacidade / Dynamic posturography and gait time: markers of functional decline in patients with multiple sclerosis and mild disabilityBruna Antinori Vignola da Fonseca 27 February 2018 (has links)
INTRODUÇÃO: As alterações do equilíbrio postural e da marcha são frequentes em pacientes com diagnóstico de esclerose múltipla (EM) e podem estar presentes tanto em indivíduos com incapacidades mínimas ou sem sinais clínicos de comprometimento, tornando-se mais pronunciados naqueles com progressão significativa da doença. No entanto, pouco se sabe sobre o declínio do controle do equilíbrio em pacientes com incapacidade leve. A posturografia é considerada uma ferramenta objetiva padrão ouro para medir o equilíbrio postural na EM. Portanto, nosso objetivo foi verificar se a posturografia dinâmica detecta as alterações do equilíbrio postural longitudinalmente, caracterizando o declínio funcional de pacientes com EM e leve incapacidade. METÓDOS: Foram avaliados pacientes com EM remitente-recorrente com baixa incapacidade de acordo com a Escala expandida do estado de incapacidade (EDSS 0 - 3,5). Após 18 meses, os pacientes foram reconvocados para a avaliação final. Avaliamos o controle do equilíbrio postural através do Teste de organização sensorial modificado (TOSm), da Posturografia dinâmica, e o tempo de marcha através do Teste de caminhada cronometrado dos 25 pés (T25FW). Todos os pacientes foram devidamente avaliados por neurologistas especialistas em EM nos dois momentos de análise do estudo. Nós comparamos todas as medidas considerando o desempenho basal e após 18 meses para cada paciente e analisamos as mudanças no controle postural ao longo da evolução da doença, de acordo com subgrupos de EDSS. RESULTADOS: 89 pacientes foram incluídos na avaliação inicial e 79 completaram o estudo. 40 sujeitos saudáveis foram incluídos no grupo controle. Não observamos diferenças significativas de idade e gênero entre os grupos. O tempo médio de doença foi de 4,9 anos (DP ±3), o escore médio do EDSS inicial de todo o grupo de pacientes com EM foi de 1,21 (DP ±0,93). Observamos diferenças significativas entre os momentos basal e 18 meses considerando as seguintes variáveis: pacientes que tiveram surtos durante o estudo ou trocaram a medicação, aumentaram o EDSS em 0,34 pontos (p=0,016) e o tempo de marcha em 0,34 segundos (p=0,012); pacientes que apresentaram novas lesões gadolínio positivas antes da reavaliação aumentaram o EDSS em 0,94 pontos (p=0,001), aumentaram o tempo de marcha em 0,99 segundos (p < 0,001), pioraram o controle do equilíbrio estático e dinâmico no TOSm (p < 0,001). Nós também observamos fortes correlações entre o aumento do EDSS e aumento do tempo de marcha (rho 0,760, p=0,001), piora do controle do equilíbrio estático (rho= -0,536, p=0,032) e piora do controle do equilíbrio dinâmico (rho= -0,660, p=0,005). Nós verificamos que à medida que o grau de incapacidade aumenta (EDSS), o desempenho em todos os testes de equilíbrio e marcha pioram (0 < 0,001). CONCLUSÕES: O desempenho de pacientes com EM na Posturografia e tempo de marcha piora à medida que a doença evolui, mesmo em pacientes com incapacidade leve. Essas alterações caracterizam o declínio funcional e estão relacionados à atividade da doença. As avaliações utilizadas no nosso estudo podem ser complementares para caracterizar o acúmulo de incapacidades em estágios iniciais. Por essa razão, a avaliação através da Posturografia e o tempo de marcha podem ser considerados marcadores de declínio funcional em pacientes com esclerose múltipla / BACKGROUND: Balance and gait disorders are common in people with multiple sclerosis (MS) and appears even in MS individuals with minimal impairment or without clinical signs, becoming more pronounced in those with significant disease progression. However, little is known about the decline in balance control in patients with mild disability. Posturography is the gold standard objective measure of postural balance in MS, being able to detect even minimal impairments. Therefore, our aim was to examine if dynamic posturography detect longitudinal postural balance decline. METHODS: We evaluated relapsing-remitting MS patients with mild disability, according to Expanded disability status scale (EDSS 0-3,5). After 18 months, all patients was contacted to return to the final evaluation. Postural balance control was evaluated through the Modified Sensorial Organization Test (mSOT), at Dynamic Posturography and the walking time was measured by Timed 25 foot walk test (T25FW). All patients were properly evaluated by MS neurologists at both moments of study analysis. We compared all measures at the baseline and after 18 months, individually. We also analyzed the postural control changes according to the EDSS subgroups. RESULTS: 89 MS patients was evaluated at baseline and 79 completed the study. 40 healthy subjects was included in control group. We did not find differences between age and sex in both groups. Median time of the disease was 4.9 years (SD±3) and the median score of EDSS was 1,21 (SD±0,93). We found significant differences between baseline and after 18 months considering some variables: patients that had relapse during the period or changed the medication worsened the EDSS score in 0.34 points (p= 0.006), increased the walking time in 0.34 seconds (p=0,012); patients with new positive gadolinium lesions between sessions increased EDSS score in 0.94 points (p=0.001), increased the walking time in 0.99 seconds (p < 0.001) and worsened static and dynamic balance control mSOT (p < 0,001). We also observed strong correlations between increased EDSS and increased gait time (rho 0.760, p=0.001), worse static balance control (rho= -0,536, p=0,032) and worse dynamic balance control (rho= - 0.660, p=0.005). As the degree of disability increases (EDSS), performance in all balance and gait tests worsens (0 < 0.001). CONCLUSIONS: MS patient\'s performance at Posturography and gait tests worsened as the disease progresses, even patients with mild disability. These changes characterize functional decline and are related to disease activity. The evaluations used in our study may be complementary to characterize the accumulation of disabilities in the early stages of the disease. For this reason, Posturography evaluation and gait timed tests may be considered markers of functional decline in patients with multiple sclerosis
|
73 |
La dyslexie du développement: étude du caractère unique ou multiple de son étiologie à l'aide d'une approche comparative et longitudinaleGenard, Nathalie January 2000 (has links)
Doctorat en sciences psychologiques / info:eu-repo/semantics/nonPublished
|
74 |
Modulação autonômica cardíaca na distrofia muscular de Duchenne durante tarefa no computador / Cardiac autonomic modulation in Duchenne muscular dystrophy during a computer taskMayra Priscila Boscolo Alvarez 18 April 2016 (has links)
Introdução: A Distrofia Muscular de Duchenne (DMD) é caracterizada como uma fraqueza muscular progressiva que leva à incapacidade. Devido às dificuldades funcionais enfrentadas pelos indivíduos com DMD, o uso da tecnologia assistiva é essencial para proporcionar ou promover habilidades funcionais. Na DMD, além do comprometimento musculoesquelético, uma disfunção autonômica cardíaca também tem sido relatada. Assim, visamos investigar as respostas autonômicas agudas de indivíduos com DMD durante a realização de uma tarefa no computador. Método: A variabilidade da frequência cardíaca foi avaliada através de métodos lineares e não lineares, utilizando uma cinta torácica com equipamento de monitoramento de eletrocardiograma (ECG). Assim, 45 indivíduos foram incluídos no grupo com DMD e 45 no grupo de desenvolvimento típico (controle), avaliados for 20 minutos em repouso sentado e 5 minutos com a realização de uma tarefa no computador. Resultados: Os indivíduos com DMD apresentaram menor modulação cardíaca parassimpática durante o repouso, que diminuiu ainda mais durante a tarefa no computador. Conclusão: Indivíduos com DMD exibiram respostas autonômicas cardíacas mais intensas durante a tarefa no computador / Introduction: Duchenne muscular dystrophy (DMD) is characterized by progressive muscle weakness that leads to disability. Due to functional difficulties faced by individuals with DMD, the use of assistive technology is essential to provide or expand functional abilities. In DMD, as well as musculoskeletal impairment, cardiac autonomic dysfunction has also been reported. Thus, we aimed to investigate acute cardiac autonomic responses in a computer task of DMD subjects. Method: Heart rate variability was evaluated through linear and nonlinear methods, using a breast strap electrocardiogram (ECG) measuring device. Thus, 45 subjects were included in the group with DMD and 45 in the typical development (control) group, assessed for 20 minutes sitting at rest and five minutes with a task on the computer. Results: Individuals with DMD had lower parasympathetic cardiac modulation at rest, which decreased further during the task on the computer. Conclusion: Individuals with DMD exhibited more intense cardiac autonomic responses during computer tasks
|
75 |
Excellent cross-cultural validity, intra-test reliability and construct validity of the Dutch Rivermead Mobility Index in patients after stroke undergoing rehabilitationRoorda, L.D., Green, J.R., De Kluis, K.R., Molenaar, I.W., Bagley, Pamela J., Smith, J., Geurts, A.C. January 2008 (has links)
OBJECTIVE: To investigate the cross-cultural validity of international Dutch-English comparisons when using the Dutch Rivermead Mobility Index (RMI), and the intra-test reliability and construct validity of the Dutch RMI. METHODS: Cross-cultural validity was studied in a combined data-set of Dutch and English patients undergoing rehabilitation after stroke, who were assessed with the Dutch version of the RMI and the original English RMI, respectively. Mokken scale analysis was used to investigate unidimensionality, monotone homogeneity model fit, and differential item functioning between the Dutch and the English RMI. Intra-test reliability and construct validity were studied in the Dutch patients by calculating the reliability coefficient and correlating the Dutch RMI and the Dutch Barthel Index. RESULTS: The RMI was completed for Dutch (n = 200) and English (n = 420) patients after stroke. The unidimensionality and monotone homogeneity model fit of the RMI were excellent: combined Dutch-English data-set (coefficient H = 0.91); Dutch data-set (coefficient H = 0.93); English data-set (coefficient H = 0.89). No differential item functioning was found between the Dutch and the English RMI. The intra-test reliability of the Dutch RMI was excellent (coefficient rho = 0.97). In a sub-sample of patients (n = 91), the Dutch RMI correlated strongly with the Dutch Barthel Index (Spearman's correlation coefficient rho = 0.84). CONCLUSION: The Dutch RMI allows valid international Dutch-English comparisons, and has excellent intra-test reliability and construct validity.
|
76 |
Avaliação da função de membros superiores: desafios na reabilitação física de pacientes pós-AVC / Upper limb functional outcomes: challenges in stroke patients rehabilitationTerranova, Thaís Tavares 22 July 2016 (has links)
INTRODUÇÃO: O acidente vascular cerebral (AVC) ocupa as primeiras posições entre as principais causas de incapacidade no mundo, sendo que 45% dos sobreviventes permanecem com perda persistente da função motora de membro superior. Diversos estudos relacionados à reabilitação de pacientes pós-AVC têm como objetivo avaliar intervenções para melhora da função motora de membros superiores. Assim, é fundamental que os resultados sejam avaliados de maneira confiável a fim de se garantir dados objetivos que facilitem a comparação entre as diferentes intervenções. No presente trabalho, discutimos as dificuldades inerentes ao contexto de seleção e administração de diferentes instrumentos de avaliação, e sugerimos uma nova metodologia com o objetivo de oferecer maior confiabilidade e sensibilidade ao processo de avaliação da funcionalidade de membros superiores em pacientes pós-AVC. MÉTODOS: Dividimos o conteúdo deste trabalho em duas etapas: I) revisão da bibliografia, na qual foram identificados diferentes instrumentos de avaliação funcional e discutidas suas propriedades psicométricas; II) análise estatística exploratória para detectar possível relação de dependência entre as variáveis obtidas pelo instrumento Wolf Motor Function Test (WMFT) e as variáveis obtidas pelo dispositivo robótico para membro superior coletadas em uma amostra de 41 pacientes em programa de reabilitação. RESULTADOS: Selecionamos 62 publicações que avaliaram as propriedades psicométricas dos instrumentos de avaliação da função de membros superiores pós-AVC. Pela análise dos artigos, identificamos 22 instrumentos e classificamos pelos níveis de funções e estruturas do corpo, e atividade de acordo com a Classificação Internacional da Funcionalidade (CIF). Comparamos os parâmetros das propriedades psicométricas dos 22 instrumentos e selecionamos o WMFT como um instrumento de referência, factível e bem conceituado, para testar a relação de dependência com as variáveis do dispositivo robótico. A partir da análise estatística exploratória, verificamos relação de dependência entre três das variáveis robóticas e a pontuação do WMFT tempo, demonstrada pela significância no teste LIS (p < 0.05), porém a correlação não foi demonstrada pela representação gráfica. CONCLUSÕES: Embora o WMFT seja bem avaliado quanto às propriedades psicométricas, ele apresenta aspectos negativos que impactam na qualidade dos dados coletados, como, por exemplo, subjetividade durante a observação, tempo de aplicação, treinamento dos avaliadores, além de não fornecer informações sobre a coordenação. Por outro lado, dispositivos robóticos produzem variáveis cinéticas e cinemáticas, as quais fornecem variáveis contínuas, objetivas e precisas sobre diferentes aspectos da função de membros superiores como velocidade, coordenação e força. Portanto, tais equipamentos são alternativas eficazes com relação à aplicação de instrumentos de avaliação do desempenho atual como o WMFT. Futuramente, sugerimos estudos que incluam uma amostra mais robusta e diversificada quanto ao grau de incapacidade, para que análise possa ser ampliada para uma modelagem estatística das variáveis / INTRODUCTION: Stroke occupies the first position among the leading causes of disability worldwide, with 45% of survivors remain with persistent loss of motor function of the upper limb. Several studies related to stroke rehabilitation evaluates interventions to improve motor function of upper limbs. Thus, it is fundamental that results are evaluated reliably in order to ensure objective data to facilitate comparison between different interventions. In this paper, we discuss the difficulties inherent in the context of selection and management of different evaluation tools and suggest a new methodology in order to provide greater reliability and sensitivity in the evaluation process of the functionality of the upper limbs in poststroke patients. METHODS: We divided the contents of this work in two steps: I) review of the literature in which identified different functional assessment tools and discussed its psychometric properties; II) exploratory statistical analysis to detect possible relationship of dependency between variables obtained by the instrument Wolf Motor Function Test (WMFT) and the variables obtained by the robotic device for upper limb collected in a sample of 41 patients in rehabilitation program. RESULTS: We selected 62 publications evaluating the psychometric properties of upper limb assessment tools. For the analysis of the articles, we identified 22 instruments and classified by levels of functions and structures of the body and activity according to the International Classification of Functioning (ICF). We compared the parameters of the psychometric properties of the 22 instruments and selected the WMFT as a reference tool, feasible and well-regarded, to test the dependency relationship with the variables of the robotic device. From the exploratory statistical analysis verified dependence between three of the robotic variables and the score WMFT time, demonstrated the significance in test LIS (p < 0.05), but the correlation was not shown by the graphical representation. CONCLUSIONS: Although WMFT has excellent psychometric properties, it has negative aspects that impact in quality of data collected, for example, subjectivity during observation, application time, training of evaluators, besides it does not provide information on the coordination. On the other hand, robotic devices produce kinetic and kinematic variables which provide continuous, accurate and objective variables on different aspects of the upper limb function such as speed, coordination and strength. Therefore, such devices are effective alternatives regarding to assessment tools of current performance as WMFT. In the future, we suggest studies that include a more robust and diverse sample with respect to the degree of disability, so that analysis can be extended to a statistical modeling of the variables
|
77 |
Responsividade do domínio subir e descer escada da escala de avaliação funcional para pessoas com distrofia muscular de Duchenne, no período de um ano / Responsiveness of the domain go up and down stair of the functional evaluation scale for Duchenne muscular dystrophy, in one year follow upAlbuquerque, Priscila Santos 19 April 2016 (has links)
Objetivo: Determinar a responsividade do domínio subir e descer escada da escala de avaliação funcional em distrofia muscular de Duchenne (DMD), no período de um ano. Método: Participaram do estudo 26 pacientes com DMD. A análise utilizou o Tamanho do Efeito (ES) e a Média Padronizada de Resposta (SRM). Resultados: Atividade de subir escada: o ES mostrou responsividade baixa nos intervalos de avaliação de 3 meses (0,26; 0,35; 0,13; 0,17), baixa a moderada em 6 meses (0,58, 0,48; 0,33), moderada em 9 meses (0,70; 0,68) e alta em 1 ano (0,88). A análise com SRM mostrou responsividade baixa nos intervalos de avaliação de 3 meses (0,29; 0,38; 0,18 e 0,19), baixa a moderada em intervalos de 6 meses (0,59 e 0,51, 0,36), moderada em 9 meses (0,74 e 0,70) e alta em 1 ano (0,89). Atividade de descer escada: O ES apresentou responsividade baixa nos intervalos de avaliação de 3 meses (0,16; 0,25; 0,09; 0,08) e 6 meses (0,48; 0,35; 0,18), baixa a moderada em 9 meses (0,59, 0,44) e moderada em 1 ano (0,71). Análise com SRM mostrou responsividade baixa nos intervalos de 3 meses (0,25; 0,35; 0,12 e 0,09) e 6 meses (0,47; 0,38 e 0,21), moderada a baixa em 9 meses (0,62, 0,49) e moderada em 1 ano (0,74). Conclusão: A avaliação da atividade de subir escada, por meio da FES-DMD-D3, deve ser realizada em intervalos a partir de 9 meses, pois a responsividade é de moderada a alta. A avaliação do descer escadas deve ser realizada anualmente, pois houve responsividade moderada somente a partir de 12 meses / Objective: To determine the responsiveness of the domain up and down stair Functional Evaluation Scale for Duchenne Muscular Dystrophy (DMD) in one year follow-up. Method: The study included 26 patients with DMD. The analysis used the Effect Size (ES) and Standardized Response Mean (SRM) tests. Results: Climbing stairs activity: the ES test showed low responsiveness in the 3-month evaluation intervals (0.26; 0.35; 0.13; 0.17), low to moderate at 6 months (0.58, 0 48; 0.33), moderate in 9 months (0.70, 0.68) and high in one year (0.88). The SRM analysis showed low response in the 3 month evaluation interval (0.29, 0.38, 0.18 and 0.19), moderate to low every 6 months (0.59 and 51, 0, 36), moderate in 9 months (0.74 and 0.70) and high in one year (0.89). Down stairs activity: The ES test showed low responsiveness in the 3 month evaluation intervals (0.16; 0.25; 0.09; 0.08) and 6 months (0.48, 0.35, 0, 18), low to moderate at 9 months (0.59, 0.44) and moderate in 1 year (0.71). SRM Analysis showed low response at intervals of 3 months (0.25; 0.35; 0.12 and 0.09) and 6 months (0.47, 0.38 and 0.21), low to moderate 9 months (0.62, 0.49) and moderate in 1 year (0.74). Conclusion: The assessment of stair climbing up should be performed in 9 months or longer intervals, when responsiveness is moderate to high. Going down stairs assessment should be performed annually, because moderate responsiveness was observed in 1 year interval
|
78 |
Desenvolvimento de software para aplicação de escala de avaliação funcional de pessoas com distrofia muscular de Duchenne e testagem de usabilidade / Development of software for application of functional assessment scale for people with Duchenne muscular dystrophy and usability testingAlbuquerque, Priscila Santos 24 February 2014 (has links)
Devido à carência de avaliações para Distrofia Muscular de Duchenne (DMD), fisioterapeutas desenvolveram e testaram a confiabilidade da Functional Evaluation Duchenne Muscular Dystrophy (FES-DMD). Visando otimizar sua aplicação foi necessário um software. O objetivo deste estudo foi desenvolver e testar a usabilidade de software para aplicação da FES-DMD. Para desenvolver o software foi necessário um engenheiro, um programador e uma fisioterapeuta. Após finalização foi realizada avaliação técnica por cinco pareceristas e aplicado teste de usabilidade com quinze fisioterapeutas especialistas, para avaliar o uso do software na prática clínica e coletar o tempo de aplicação da FES-DMD. De acordo com as características exigidas o software foi desenvolvido com especificações: linguagem Visual Basic. Net, base de dados SQL Compact Server, Plataforma Windows XP sp3 ou superiores, Hardware de suporte, tela com resolução 1024X768 e formato do vídeo WMV/MP4. Estas permitem que o software tenha banco de dados seguro, cadastro de usuários, visualização de filmes, preenchimento da escala, cálculo do escore e geração de relatório. Como resultados, a avaliação técnica contribuiu com Layout e o teste de usabilidade mostrou que dez de quinze fisioterapeutas concordam fortemente que o software é usável na prática clínica, três concordam, enquanto que um discorda e outro discorda fortemente. Com relação ao tempo de aplicação, a FESDMD no software se mostrou mais rápida (p < 0.001). Foi possível desenvolver software para aplicação da FES-DMD. O instrumento promove ganho de tempo do fisioterapeuta, armazena dados e imagens de forma segura, gera relatórios e é usável na prática clínica / Due to the lack of reviews for Duchenne Muscular Dystrophy (DMD), physiotherapists have developed and tested a confiabiliade Functional Evaluation of Duchenne Muscular Dystrophy (FES-DMD). In order to optimize your application was necessary software. The aim of this study was to develop and test the usability of software for application of FES-DMD. To develop the necessary software was an engineer, a programmer and a physiotherapist. After finalizing technical evaluation was carried out for five referees and applied usability testing with fifteen physiotherapists experts to evaluate the use of software in clinical practice and collect the time of application of FES-DMD. According to the characteristics required software has been developed with specifications: Visual Basic language.Net, database SQL Server Compact Platform, Windows XP sp3 or higher, Hardware Support, 1024X768 screen resolution and video format WMV/MP4. These allow the software to be secure database, user registration, inhouse movies, completing the scale score calculation and reporting. As a result, the technical evaluation contributed Layout and usability test showed that ten fifteen physiotherapists strongly agree that the software is usable in clinical practice, three agree, while one disagreed and one strongly disagrees. Regarding the time of application, the FES- DMD in software is faster (p < 0.001). It was possible to develop software for the application of FES- DMD. The instrument promotes gain time physiotherapist, stores images and data securely, generate reports, and is usable in clinical practice
|
79 |
Disease and disability in early rheumatoid arthritis : a 3-year follow-up of women and men in the Swedish TIRA project /Thyberg, Ingrid, January 2005 (has links) (PDF)
Diss. (sammanfattning) Linköping : Linköpings universitet, 2005. / Härtill 4 uppsatser.
|
80 |
Women with fibromyalgia : employment and daily life /Liedberg, Gunilla, January 2004 (has links)
Diss. (sammanfattning) Linköping :Univ., 2004. / Härtill 5 uppsatser.
|
Page generated in 0.0988 seconds