• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 25
  • 3
  • 1
  • 1
  • 1
  • Tagged with
  • 30
  • 30
  • 25
  • 25
  • 24
  • 13
  • 12
  • 12
  • 8
  • 8
  • 7
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Acurária do estudo dos jatos ureterais à ultra-sonografia do Doppler Colorido no diagnóstico das hidronefroses / Diagnostic accuracy of color Doppler sonographic study of the ureteric jets in evaluation of hydronephrosis

Bessa Junior, José de 10 August 2007 (has links)
Introdução e Objetivo: Hidronefrose e Obstrução são condições associadas, entretanto dilatações da via excretora podem ocorrer na ausência de obstruções clinicamente importantes. Ultra-sonografia convencional e Renograma com Diuréticos são os métodos diagnósticos complementares mais utilizados na avaliação das hidronefroses na infância. Recentes trabalhos têm demonstrado a possibilidade de observarmos os jatos ureterais com o Estudo Ultra-sonográfico com Doppler Colorido e sugerido a sua aplicação no diagnóstico diferencial das hidronefroses. O objetivo do presente trabalho foi avaliar a aplicabilidade do estudo dos jatos ureterais como método diagnóstico na identificação das hidronefroses obstrutivas e não obstrutivas na população pediátrica. Métodos: Foram estudadas 48 crianças (35 meninos e 13 meninas) com idade que variou de um mês a 14 anos (mediana de 4 anos), que se apresentaram com Hidronefroses Unilaterais, Graus III e IV, e com suspeita de obstrução da junção pieloureteral. Todos os sujeitos foram submetidos ao Estudo dos jatos ureterais e ao Renograma com Diuréticos num período de duas semanas. As unidades hidronefróticas foram consideradas obstruídas quando a Função Renal Diferencial era menor do que 40%, ou em indivíduos mais velhos que apresentavam dor lombar intermitente. Os jatos ureterais de cada meato foram contados por um período de 5 minutos e considerados separadamente. Freqüência Relativa dos Jatos (FRJ) foi definida como o numero de jatos ureterais no lado afetado dividido pela soma dos jatos ureterais observados bilateralmente. Resultados: Vinte e duas (45,8%) unidades hidronefróticas foram consideradas obstruídas.A média da FRJ diferiu significativamente entre as hidronefroses obstrutivas (0,09 ± 0,15) e não obstrutivas (0,41 ± 0,11). (p<0.001). Análise da Curva ROC revelou que FRJ < 0,25 é o melhor valor que distingue as hidronefroses obstrutivas e não obstrutivas e o faz corretamente em 91,2 % dos casos, com uma Sensibilidade de 86,4% (IC95%=78,6-98,2%) e Especificidade de of 96.15% (IC95%=87.8-99%). O Índice de Probabilidade Positivo foi de 22,45 e a Razão de Chances Diagnóstica de 158,3. A área sob a curva ROC foi de 0,91 (IC95%=0,86-0,98) indicando a excelente acurácia do método. Conclusões: FRJ < 25 % mostrou ser um bom indicador de obstrução nas hidronefroses unilaterais da infância. O estudo dos jatos ureterais a Ultrasonografia com Doppler Colorido é método simples, não invasivo e pode ser utilizado na abordagem inicial e no seguimento, na diferenciação das hidronefroses obstrutivas e não obstrutivas na população pediátrica / Introduction and Objective: Hydronephrosis (HN) and obstruction are closely associated, but upper urinary tract dilatation can occur without significant obstruction. Despite some pitfalls, conventional ultrasonography and diuretic renography (DR) are the main modalities in the evaluation of HN in children. Recent reports have demonstrated the usefulness of Color Doppler Ultrasonography (CDUS) as a reliable method to identify the ureteric jets (UJ) in the bladder. The aim of this study was to evaluate CDUS evaluation of the UJ in the bladder as a diagnostic tool to distinguish obstructive from non-obstructive dilatations of the upper tract in pediatric population. Methods: We evaluated 48 patients (35 boys and 13 girls), aged 1 month to 14 years (median = 4 ys.), who presented with unilateral grade III and IV hydronephrosis suspicious of pyeloureteral junction obstruction. All patients underwent DR and evaluation of UJ by transverse CDSG of the bladder within a maximum of 2 weeks. Obstruction was considered in the DR when the hydronephrotic unit showed Differential Renal Function of less than 40%, or when symptomatic intermittent renal colic was present in older children. The number of UJ was counted over a 5 min period and its frequency was calculated for each ureteral orifice. Relative Jet Frequency (RJF) was defined as the UJ frequency of hydronephrotic side divided by total UJ frequency. Receiver-Operating Characteristic (ROC) plots were constructed to determine the best cuttoff for RJF, in order to identify renal units with obstructive hydronephrosis. Results:Twenty-two(45.8%) hydronephrotic units were considered obstructed. The mean RJF differed significantly between obstructive (0.09 ± 0,15) and non-obstructive hydronephrosis (0.41± 0.11)(p<0.001). ROC analysis revealed that RJF< 0.25 was the best threshold and it correctly discriminates obstruction in 91.2% of the childrens with a sensitivity of 86.4% (95%CI=78.6-98.2%) and specificity of 96.15% (95%CI=87,8-99%). The Positive Likelihood Ratio was 22.45 and Diagnostic Odds Ratio was 158.3.The area under the ROC curve was 0.91 (95%CI=0.86-0.98), indicating excellent discrimination power. Conclusions: In this study RJF < 25% was found to be a good indicator of obstruction in children with unilateral hydronephrosis. CDUS evaluation of UJ is an easy and non-invasive method that can be used as an initial diagnostic tool and in follow-up cases, to differentiate obstructed from non-obstructed hydronephrosis in the pediatric population
12

Acurácia da ultrassonografia com Doppler colorido na identificação de doença maligna em neoplasias foliculares da tireóide / Accuracy of color Doppler ultrasonography to identify malignancies in thyroid follicular neoplasms

Iared, Wagner [UNIFESP] 26 May 2010 (has links) (PDF)
Made available in DSpace on 2015-07-22T20:49:17Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-05-26. Added 1 bitstream(s) on 2015-08-11T03:26:24Z : No. of bitstreams: 1 Publico-251a.pdf: 353518 bytes, checksum: e03912dc2d4dcadf8fed24a5e27962a1 (MD5). Added 1 bitstream(s) on 2015-08-11T03:26:25Z : No. of bitstreams: 2 Publico-251a.pdf: 353518 bytes, checksum: e03912dc2d4dcadf8fed24a5e27962a1 (MD5) Publico-251b.pdf: 370261 bytes, checksum: 21113711cf007d18765e8fd06ce0b74d (MD5). Added 1 bitstream(s) on 2015-08-11T03:26:25Z : No. of bitstreams: 3 Publico-251a.pdf: 353518 bytes, checksum: e03912dc2d4dcadf8fed24a5e27962a1 (MD5) Publico-251b.pdf: 370261 bytes, checksum: 21113711cf007d18765e8fd06ce0b74d (MD5) Publico-251c.pdf: 708805 bytes, checksum: c133f7b882649d8ce6a6e41d70d8127e (MD5). Added 1 bitstream(s) on 2015-08-11T03:26:25Z : No. of bitstreams: 4 Publico-251a.pdf: 353518 bytes, checksum: e03912dc2d4dcadf8fed24a5e27962a1 (MD5) Publico-251b.pdf: 370261 bytes, checksum: 21113711cf007d18765e8fd06ce0b74d (MD5) Publico-251c.pdf: 708805 bytes, checksum: c133f7b882649d8ce6a6e41d70d8127e (MD5) Publico-251d.pdf: 1551671 bytes, checksum: 4b389eb595b13be306af85e44e227d6c (MD5). Added 1 bitstream(s) on 2015-08-11T03:26:25Z : No. of bitstreams: 5 Publico-251a.pdf: 353518 bytes, checksum: e03912dc2d4dcadf8fed24a5e27962a1 (MD5) Publico-251b.pdf: 370261 bytes, checksum: 21113711cf007d18765e8fd06ce0b74d (MD5) Publico-251c.pdf: 708805 bytes, checksum: c133f7b882649d8ce6a6e41d70d8127e (MD5) Publico-251d.pdf: 1551671 bytes, checksum: 4b389eb595b13be306af85e44e227d6c (MD5) Publico-251e.pdf: 1825649 bytes, checksum: 913727f9a754c440b9d3b488b707f7a9 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Contexto. A diferenciação entre os nódulos benignos e malignos da tireoide é possível na maioria das vezes pela citologia, obtida por punção aspirativa com agulha fina (PAAF). No caso das neoplasias foliculares (NFs), é necessária a remoção cirúrgica de ao menos parte da glândula, pois somente a análise histológica da peça permite diferenciar nódulos benignos de malignos. Há indícios na literatura de que os parâmetros de ultrassonografia com Doppler colorido (UDC) podem indicar maior ou menor probabilidade de malignidade nesses nódulos. Objetivo. Avaliar, nesta revisão sistemática, a acurácia diagnóstica da UDC em predizer malignidade em NFs da tireoide. Métodos. Foram pesquisadas as seguintes bases de dados: MEDLINE, Web of Science, EMBASE, Cochrane Library e LILACS. As referências de estudos relevantes foram verificadas para adicionais citações de interesse. Não houve restrições de linguagem. Foram incluídos estudos nos quais nódulos de tireoide com padrão histológico compatível com NFs, confirmado por biópsia de peça cirúrgica, haviam sido previamente submetidos à UDC e cujos padrões de fluxo ao mapeamento colorido foram descritos detalhadamente. Dois revisores realizaram independentemente a avaliação da qualidade e a extração de dados. Resultados. Foram incluídos quatro estudos, somando 457 nódulos, sendo que 67 foram considerados malignos com base na biópsia cirúrgica. A presença à UDC de padrões de fluxo no interior do nódulo considerado como moderado, rico, predominante ou exclusivo foi indicativa de malignidade com uma sensibilidade média de 85 % (Intervalo de confiança [IC] 95%: 74% a 93%) e especificidade média de 86% (IC 95%: 82% a 89%). Para uma prevalência média de 14,7%, os valores preditivos positivo e negativo são respectivamente 51% e 97%. A razão de verossimilhança positiva é 6,07, e a razão de verossimilhança negativa 0,18. Conclusão. A UDC apresenta boa acurácia para identificar malignidade em NFs da tireóide. Fluxo interno predominante à UDC está associado a maior risco de malignidade nessas lesões. / Background. In most cases it is possible to differentiate between benign and malignant thyroid nodules through cytologic analysis of the fine-needle aspiration biopsy (FNAB) samples. However, in the case of follicular neoplasms (FNs), to determine whether such nodules are benign or malignant, it is necessary to perform a surgical biopsy, which requires the removal of at least part of the thyroid gland. There are clues in the literature that the parameters of color Doppler ultrasonography (CDU) may indicate a greater or lesser likelihood of malignancy in these nodules. Objective. The purpose of this systematic review was to obtain summary estimates of the diagnostic accuracy of CDU in predicting malignancy in thyroid FNs. Methods. We searched Medical Subject Headings together with the search terms “follicular,” “thyroid,” and “Doppler” in the MEDLINE, Web of Science, Cochrane Library and Excerpta Medica databases as well as the Latin American and Caribbean Health Sciences Literature database, after which we performed manual searches of the reference lists to locate additional studies. There were no language restrictions. We included studies that assessed the diagnostic accuracy of CDU in identifying malignancy in thyroid FNs. The assessments of the quality and extraction of data were performed by 2 independent reviewers. Results. We included 4 studies, which collectively evaluated 457 thyroid FNs, 67 of which had been classified as malignant based on the evaluation of surgical biopsy samples. Moderate, rich, predominant, or exclusive internal flow on CDU of thyroid FNs was considered indicative of malignancy. The overall sensitivity of CDU was 85% (95% confidence interval [CI], 74%–93%), with an overall specificity of 86% (95% CI, 82%–89%). The overall prevalence was 14.7%, and the positive and negative predictive values were 51% and 97%, respectively. The positive likelihood ratio was 6.07, and the negative likelihood ratio was 0.18. Conclusion. CDU has good accuracy for identifying malignancy in thyroid FN. Predominant internal flow seen on CDU is associated with malignancy of thyroid FN. / TEDE / BV UNIFESP: Teses e dissertações
13

Correlação entre a ressonância magnética e a ultra-sonografia com duplex scan colorido no diagnóstico da trombose venosa profunda dos membros inferiores / Correlation between magnetic resonance and duplex color sonography in diagnosis of deep venous thrombosis in lower limbs

Flávio Mendes de Andrade Neto 07 May 2007 (has links)
A trombose venosa profunda é uma doença que acomete o sistema venoso profundo, com formação de trombos dentro de uma veia e conseqüente reação inflamatória do vaso. O trombo pode determinar a obstrução parcial ou total do vaso. Ocorre em maior número nos membros inferiores e pelve. O quadro normalmente é agudo, mas pode se tornar crônico, com recidivas. Na maior parte dos casos, acomete os membros de forma unilateral. No presente estudo, foram utilizados dois métodos de diagnóstico por imagem na detecção de trombose venosa profunda, que foram a ultra-sonografia em escala de cinza (modo B) associada ao Duplex Scan colorido, e a ressonância magnética. Neste último, foi utilizado meio de contraste paramagnético (Gadolínio) através de administração venosa pediosa. Foram estudados um total de 26 pacientes, 47 membros inferiores e 141 segmentos corporais. A comparação entre os métodos de imagem foi feita por segmento venoso e por segmento corporal. O objetivo do estudo foi avaliar a concordância diagnóstica entre os métodos e a confiabilidade interobservadores nos exames de ressonância magnética, bem como avaliar a sensibilidade, especificidade e acurácia do Duplex Scan colorido em relação à ressonância magnética por segmentos venosos e corporais. Como conclusões do estudo, notamos que houve boa correlação entre a ultrasonografia e a ressonância magnética nos segmentos femorais comuns e superficiais, perfurantes da coxa, poplíteas, tibiais posteriores, fibulares e ilíacas externas. Também houve boa correlação entre os métodos na avaliação das coxas e pernas, e ausência de correlação significativa na pelve. Houve boa confiabilidade interobservadores nos exames de ressonância magnética por segmento venoso. A sensibilidade da ultrasonografia em relação à ressonância magnética foi excelente na pelve, coxas e pernas, sendo a especificidade e acurácia altas na coxa e perna, e baixas na pelve / Deep venous thrombosis is a disease that occurs in deep venous system, with thrombi formation into a vein, and consequent vascular inflammatory reaction. This thrombus can determine partial or total vascular occlusion. It occurs mostly in the lower limbs and pelvis. Clinical presentation is usually acute, but may also be chronic with relapses. In most cases, limb disease is unilateral. In the present study, two different imaging techniques were used in the diagnosis of deep venous thrombosis: B-mode sonography with duplex color Doppler and magnetic resonance imaging with pedal vein administration of paramagnetic contrast media. Twenty-six patients, 47 lower extremities and 141 body segments were evaluated. Comparasion between techniques was made by vascular segments and body segments.The objectives of the study were to evaluate agreement in diagnosis between methods by vascular and body segments, interobserver reliability to read magnetic resonance exams, and sensibility, specificity and accuracy of duplex color sonography in relation to magnetic resonance imaging by vascular and body segments. In conclusion, there was a good correlation between ultrasound and magnetic resonance imaging at common and superficial femoral vein segments, thigh perfurants, calf veins, posterior tibial, fibular and external iliac veins. There was a good correlation between techniques in the evaluation of thighs and legs, but not in the pelvis. There was a good interobserver reliability in the evaluation of vascular segments by magnetic resonance imaging. The sensibility of duplex color sonography in relation to magnetic resonance imaging was excellent in pelvis, thighs and legs; specificity and accuracy were high in thighs and legs, and low in the pelvis
14

Acurária do estudo dos jatos ureterais à ultra-sonografia do Doppler Colorido no diagnóstico das hidronefroses / Diagnostic accuracy of color Doppler sonographic study of the ureteric jets in evaluation of hydronephrosis

José de Bessa Junior 10 August 2007 (has links)
Introdução e Objetivo: Hidronefrose e Obstrução são condições associadas, entretanto dilatações da via excretora podem ocorrer na ausência de obstruções clinicamente importantes. Ultra-sonografia convencional e Renograma com Diuréticos são os métodos diagnósticos complementares mais utilizados na avaliação das hidronefroses na infância. Recentes trabalhos têm demonstrado a possibilidade de observarmos os jatos ureterais com o Estudo Ultra-sonográfico com Doppler Colorido e sugerido a sua aplicação no diagnóstico diferencial das hidronefroses. O objetivo do presente trabalho foi avaliar a aplicabilidade do estudo dos jatos ureterais como método diagnóstico na identificação das hidronefroses obstrutivas e não obstrutivas na população pediátrica. Métodos: Foram estudadas 48 crianças (35 meninos e 13 meninas) com idade que variou de um mês a 14 anos (mediana de 4 anos), que se apresentaram com Hidronefroses Unilaterais, Graus III e IV, e com suspeita de obstrução da junção pieloureteral. Todos os sujeitos foram submetidos ao Estudo dos jatos ureterais e ao Renograma com Diuréticos num período de duas semanas. As unidades hidronefróticas foram consideradas obstruídas quando a Função Renal Diferencial era menor do que 40%, ou em indivíduos mais velhos que apresentavam dor lombar intermitente. Os jatos ureterais de cada meato foram contados por um período de 5 minutos e considerados separadamente. Freqüência Relativa dos Jatos (FRJ) foi definida como o numero de jatos ureterais no lado afetado dividido pela soma dos jatos ureterais observados bilateralmente. Resultados: Vinte e duas (45,8%) unidades hidronefróticas foram consideradas obstruídas.A média da FRJ diferiu significativamente entre as hidronefroses obstrutivas (0,09 ± 0,15) e não obstrutivas (0,41 ± 0,11). (p<0.001). Análise da Curva ROC revelou que FRJ < 0,25 é o melhor valor que distingue as hidronefroses obstrutivas e não obstrutivas e o faz corretamente em 91,2 % dos casos, com uma Sensibilidade de 86,4% (IC95%=78,6-98,2%) e Especificidade de of 96.15% (IC95%=87.8-99%). O Índice de Probabilidade Positivo foi de 22,45 e a Razão de Chances Diagnóstica de 158,3. A área sob a curva ROC foi de 0,91 (IC95%=0,86-0,98) indicando a excelente acurácia do método. Conclusões: FRJ < 25 % mostrou ser um bom indicador de obstrução nas hidronefroses unilaterais da infância. O estudo dos jatos ureterais a Ultrasonografia com Doppler Colorido é método simples, não invasivo e pode ser utilizado na abordagem inicial e no seguimento, na diferenciação das hidronefroses obstrutivas e não obstrutivas na população pediátrica / Introduction and Objective: Hydronephrosis (HN) and obstruction are closely associated, but upper urinary tract dilatation can occur without significant obstruction. Despite some pitfalls, conventional ultrasonography and diuretic renography (DR) are the main modalities in the evaluation of HN in children. Recent reports have demonstrated the usefulness of Color Doppler Ultrasonography (CDUS) as a reliable method to identify the ureteric jets (UJ) in the bladder. The aim of this study was to evaluate CDUS evaluation of the UJ in the bladder as a diagnostic tool to distinguish obstructive from non-obstructive dilatations of the upper tract in pediatric population. Methods: We evaluated 48 patients (35 boys and 13 girls), aged 1 month to 14 years (median = 4 ys.), who presented with unilateral grade III and IV hydronephrosis suspicious of pyeloureteral junction obstruction. All patients underwent DR and evaluation of UJ by transverse CDSG of the bladder within a maximum of 2 weeks. Obstruction was considered in the DR when the hydronephrotic unit showed Differential Renal Function of less than 40%, or when symptomatic intermittent renal colic was present in older children. The number of UJ was counted over a 5 min period and its frequency was calculated for each ureteral orifice. Relative Jet Frequency (RJF) was defined as the UJ frequency of hydronephrotic side divided by total UJ frequency. Receiver-Operating Characteristic (ROC) plots were constructed to determine the best cuttoff for RJF, in order to identify renal units with obstructive hydronephrosis. Results:Twenty-two(45.8%) hydronephrotic units were considered obstructed. The mean RJF differed significantly between obstructive (0.09 ± 0,15) and non-obstructive hydronephrosis (0.41± 0.11)(p<0.001). ROC analysis revealed that RJF< 0.25 was the best threshold and it correctly discriminates obstruction in 91.2% of the childrens with a sensitivity of 86.4% (95%CI=78.6-98.2%) and specificity of 96.15% (95%CI=87,8-99%). The Positive Likelihood Ratio was 22.45 and Diagnostic Odds Ratio was 158.3.The area under the ROC curve was 0.91 (95%CI=0.86-0.98), indicating excellent discrimination power. Conclusions: In this study RJF < 25% was found to be a good indicator of obstruction in children with unilateral hydronephrosis. CDUS evaluation of UJ is an easy and non-invasive method that can be used as an initial diagnostic tool and in follow-up cases, to differentiate obstructed from non-obstructed hydronephrosis in the pediatric population
15

Ultra-sonografia convencional e com Doppler colorido no diagnóstico de estenose da veia porta e da veia hepática em crianças submetidas a transplante hepático segmentar / Portal and Hepatic venous stenoses after pediatric segmental liver transplantation: the role of real time and Doppler ultrasound

Suzuki, Lisa 10 May 2006 (has links)
INTRODUÇÃO: Nos pacientes pediátricos, em razão das limitações relacionadas ao tamanho dos receptores, são utilizados segmentos do fígado provenientes de \"cadáver\" ou de doador vivo (\"fígado reduzido\"). As complicações decorrentes das anastomoses cirúrgicas podem ser de natureza vascular e biliar, sendo que a maior causa de perda do enxerto deve-se à trombose ou estenose da artéria hepática, veia porta e veias hepáticas. A ultra-sonografia convencional e com Doppler colorido (US-DC) pode ser utilizada para avaliação dessas complicações. Todavia, apesar da alta sensibilidade e especificidade deste método, há poucas descrições a respeito de parâmetros que podem ser utilizados para o estudo das alterações vasculares. OBJETIVO: Estabelecer parâmetros de ultra-sonografia convencional e com Doppler colorido (US-DC) para o diagnóstico de estenose da VP e VH no transplante hepático reduzido em crianças. MÉTODO: Estudo retrospectivo de 134 US-DC realizado em 48 crianças submetidas a transplante hepático segmentar no Instituto da Criança do Hospital das Clinicas da Faculdade de Medicina da Universidade de São Paulo (ICr-HC-FMUSP), entre janeiro de 2002 e julho de 2005. No estudo da VP, os seguintes parâmetros foram analisados: calibre da VP na anastomose; velocidade máxima na anastomose (VP1); velocidade máxima no segmento pré-anastomose (VP2) e relação entre as velocidades máximas na anastomose/préanastomose (VP1/VP2). No estudo da VH, foram analisados: velocidade máxima na anastomose (VH1); velocidade na VH (VH2) e relação entre as velocidades máximas na anastomose/VH (VH1/VH2). Pacientes com estenose confirmada pela angiografia foram incluídos no grupo estenose e pacientes com angiografia ou cirurgia normal ou com boa evolução clínica foram incluídos grupo controle. RESULTADOS: Quatorze US-DC tiveram estenose da VP confirmadas pela portografia. O calibre da VP na anastomose foi menor no grupo estenose do que no grupo controle (média 2,5mm e 6,3mm respectivamente); PV1 e PV1/PV2 foram maiores no grupo estenose do que no grupo controle (média PV1 = 172cm/s, PV1/PV2 = 5,1 / PV1 = 83cm/s, PV1/PV2 = 1,8 respectivamente). O calibre da VP < 3,3mm apresentou a melhor correlação com a portografia (sensibilidade = 93% e especificidade = 88%), seguidos de VP1 > 128cm/s (sensibilidade = 86% e especificidade = 84%) e VP1/VP2 > 2,4 (sensibilidade = 79% e especificidade = 86%). Doze US-DC tiveram estenose da VH confirmada pela angiografia. A VH1 e HV1/VH2 foram maiores no grupo estenose do que no grupo controle (média VH1 = 202.2cm/s, VH1/VH2 = 6,0 / VH1 = 136,8cm/s, VH1/VH2 = 3,0 respectivamente). A relação VH1/VH2 > 4 apresentou a melhor correlação com a angiografia (sensibilidade = 83% e especificidade = 84%) seguido de VH1 > 128cm/s (sensibilidade = 83% e especificidade = 52%). CONCLUSÃO: Calibre da VP < 3,3mm na anastomose e relação das velocidades VH1/VH2 > 4 são altamente sensíveis e específicos no diagnóstico das estenoses da anastomose da VP e VH respectivamente, no póstransplante hepático em crianças / INTRODUCTION: Cadáveric split liver and living donor liver transplantation is mostly performed in children because of a shortage of suitable hepatic allograft in this population. Real time and Doppler ultrasound (CD-US) is the initial imaging modality for detection and follow-up of early and delayed vascular and non-vascular complications after liver transplant, but there are only few studies concerning its value in the diagnosis of venous complications. OBJECTIVE: Determine real time and Doppler ultrasound (CD-US) diagnostic parameters of portal (PV) and hepatic vein (HV) stenoses after segmental liver transplantation in children and assess their sensitivity and specificity. METHOD: Retrospective study of 134 CD-US performed in 48 patients submitted to segmental liver transplantation at Child Institute of University of Sao Paulo Medical School from January 2002 through July 2005. PV parameters: diameter at the anastomosis, velocities at the anastomosis (PV1) and at the pre-anastomosis segments (PV2) and the ratio PV1/PV2. HV parameters: velocities at the HV anastomosis to the inferior vena cava (HV1), at HV (HV2) and the ratio HV1/HV2. Stenosis group: patients with stenosis confirmed by angiography. Control group: patients presenting normal angiography or uneventhfull surgery or good clinical outcome. RESULTS: Fourteen CD-US had PV stenosis confirmed by portography. Diameter of PV at the anastomosis: narrower in the stenosis group (2.5mm) than in the control group (6.3mm) (p<.5). Mean PV1 and PV1/PV2: higher in the stenosis group than in the control group (PV1 = 172 cm/s, PV1/PV2 = 5.1/PV1 = 83cm/s, PV1/PV2 = 1.8). Statistical analysis determined as predictive of PV stenosis: PV diameter < 3.3mm (sensitivity of 93% and specificity of 88.4%); PV1 > 128cm/s (sensitivity of 86% and specificity of 84%) and PV1/PV2 > 2.4 (sensitivity of 79% and specificity of 86%). Twelve CD-US had HV stenosis confirmed by angiography. Mean HV1 and HV1/HV2: higher in the study group (HV1 = 202.2cm/s, HV1/HV2 = 6.0 / HV1 = 136.8cm/s, HV1/HV2 = 3.0) (p<.05). Statistical analysis determined as predictive of HV stenosis: PV1 > 128cm/s (sensitivity of 83% and specificity of 52%) and HV1/HV2 > 4 (sensitivity of 83% and specificity of 84%). CONCLUSION: PV diameter < 3.3mm at the anastomosis and HV1/HV2 > 4.0 are highly predictive for detection of PV and HV stenosis respectively, after pediatric segmental liver transplantation
16

"Importância da ecocardiografia com contraste por microbolhas em imagem fundamental na avaliação de pacientes sob ventilação mecânica no período pós-operatório de cirurgia cardíaca" / Contrast echocardiography can save non-diagnostic exams in mechanically ventilated patients

Costa, Joicely Melo da 27 March 2006 (has links)
Estudou-se pela ecocardiografia em imagem fundamental, 30 pacientes no período pós-operatório de cirurgia cardíaca que encontravam se sob ventilação mecânica. Analisou-se o índice de escore de delineamento endocárdico (IEDE), a fração de ejeção do ventrículo esquerdo (FEVE) pelo método de estimativa visual, e os fluxos transvalvares pelo Doppler espectral e mapeamento de fluxo em cores antes e após a administração de um contraste ecocardiográfico a base de microbolhas. O IEDE passou de 1,53±0,63 para 2,01±0,56 após o uso do contraste (p < 0.001) e a FEVE pôde ser estimada em 27 de 30 exames após o uso do mesmo. Houve uma mudança na quantificação da insuficiência mitral em 5 exames, no gradiente de pico transvalvar aórtico em 1 paciente e no gradiente transvalvar de pico tricúspide em 8 pacientes / We studied by echocardiography in fundamental imaging (FI), thirty mechanically ventilated post cardiac surgery patients. LV endocardial border delineation score index (EBDSI), estimated left ventricular ejection fraction (LVEF) and color and spectral Doppler were analyzed before and after intravenous injection of ultrasound contrast. The use of contrast resulted in a significant increase in the number of well-delineated segments. EBDSI was 1.53±0.63, before contrast, increasing to 2.01±0.56 after it (p < 0.001). The LVEF could be evaluated in 27 of 30 exams after contrast. There was a change in the quantification of mitral regurgitation in 5 exams, in the aortic transvalvular peak gradient in 1 patient and measurement of peak flow velocity of tricuspid regurgitation in 8 patients
17

Ultra-sonografia convencional e com Doppler colorido no diagnóstico de estenose da veia porta e da veia hepática em crianças submetidas a transplante hepático segmentar / Portal and Hepatic venous stenoses after pediatric segmental liver transplantation: the role of real time and Doppler ultrasound

Lisa Suzuki 10 May 2006 (has links)
INTRODUÇÃO: Nos pacientes pediátricos, em razão das limitações relacionadas ao tamanho dos receptores, são utilizados segmentos do fígado provenientes de \"cadáver\" ou de doador vivo (\"fígado reduzido\"). As complicações decorrentes das anastomoses cirúrgicas podem ser de natureza vascular e biliar, sendo que a maior causa de perda do enxerto deve-se à trombose ou estenose da artéria hepática, veia porta e veias hepáticas. A ultra-sonografia convencional e com Doppler colorido (US-DC) pode ser utilizada para avaliação dessas complicações. Todavia, apesar da alta sensibilidade e especificidade deste método, há poucas descrições a respeito de parâmetros que podem ser utilizados para o estudo das alterações vasculares. OBJETIVO: Estabelecer parâmetros de ultra-sonografia convencional e com Doppler colorido (US-DC) para o diagnóstico de estenose da VP e VH no transplante hepático reduzido em crianças. MÉTODO: Estudo retrospectivo de 134 US-DC realizado em 48 crianças submetidas a transplante hepático segmentar no Instituto da Criança do Hospital das Clinicas da Faculdade de Medicina da Universidade de São Paulo (ICr-HC-FMUSP), entre janeiro de 2002 e julho de 2005. No estudo da VP, os seguintes parâmetros foram analisados: calibre da VP na anastomose; velocidade máxima na anastomose (VP1); velocidade máxima no segmento pré-anastomose (VP2) e relação entre as velocidades máximas na anastomose/préanastomose (VP1/VP2). No estudo da VH, foram analisados: velocidade máxima na anastomose (VH1); velocidade na VH (VH2) e relação entre as velocidades máximas na anastomose/VH (VH1/VH2). Pacientes com estenose confirmada pela angiografia foram incluídos no grupo estenose e pacientes com angiografia ou cirurgia normal ou com boa evolução clínica foram incluídos grupo controle. RESULTADOS: Quatorze US-DC tiveram estenose da VP confirmadas pela portografia. O calibre da VP na anastomose foi menor no grupo estenose do que no grupo controle (média 2,5mm e 6,3mm respectivamente); PV1 e PV1/PV2 foram maiores no grupo estenose do que no grupo controle (média PV1 = 172cm/s, PV1/PV2 = 5,1 / PV1 = 83cm/s, PV1/PV2 = 1,8 respectivamente). O calibre da VP < 3,3mm apresentou a melhor correlação com a portografia (sensibilidade = 93% e especificidade = 88%), seguidos de VP1 > 128cm/s (sensibilidade = 86% e especificidade = 84%) e VP1/VP2 > 2,4 (sensibilidade = 79% e especificidade = 86%). Doze US-DC tiveram estenose da VH confirmada pela angiografia. A VH1 e HV1/VH2 foram maiores no grupo estenose do que no grupo controle (média VH1 = 202.2cm/s, VH1/VH2 = 6,0 / VH1 = 136,8cm/s, VH1/VH2 = 3,0 respectivamente). A relação VH1/VH2 > 4 apresentou a melhor correlação com a angiografia (sensibilidade = 83% e especificidade = 84%) seguido de VH1 > 128cm/s (sensibilidade = 83% e especificidade = 52%). CONCLUSÃO: Calibre da VP < 3,3mm na anastomose e relação das velocidades VH1/VH2 > 4 são altamente sensíveis e específicos no diagnóstico das estenoses da anastomose da VP e VH respectivamente, no póstransplante hepático em crianças / INTRODUCTION: Cadáveric split liver and living donor liver transplantation is mostly performed in children because of a shortage of suitable hepatic allograft in this population. Real time and Doppler ultrasound (CD-US) is the initial imaging modality for detection and follow-up of early and delayed vascular and non-vascular complications after liver transplant, but there are only few studies concerning its value in the diagnosis of venous complications. OBJECTIVE: Determine real time and Doppler ultrasound (CD-US) diagnostic parameters of portal (PV) and hepatic vein (HV) stenoses after segmental liver transplantation in children and assess their sensitivity and specificity. METHOD: Retrospective study of 134 CD-US performed in 48 patients submitted to segmental liver transplantation at Child Institute of University of Sao Paulo Medical School from January 2002 through July 2005. PV parameters: diameter at the anastomosis, velocities at the anastomosis (PV1) and at the pre-anastomosis segments (PV2) and the ratio PV1/PV2. HV parameters: velocities at the HV anastomosis to the inferior vena cava (HV1), at HV (HV2) and the ratio HV1/HV2. Stenosis group: patients with stenosis confirmed by angiography. Control group: patients presenting normal angiography or uneventhfull surgery or good clinical outcome. RESULTS: Fourteen CD-US had PV stenosis confirmed by portography. Diameter of PV at the anastomosis: narrower in the stenosis group (2.5mm) than in the control group (6.3mm) (p<.5). Mean PV1 and PV1/PV2: higher in the stenosis group than in the control group (PV1 = 172 cm/s, PV1/PV2 = 5.1/PV1 = 83cm/s, PV1/PV2 = 1.8). Statistical analysis determined as predictive of PV stenosis: PV diameter < 3.3mm (sensitivity of 93% and specificity of 88.4%); PV1 > 128cm/s (sensitivity of 86% and specificity of 84%) and PV1/PV2 > 2.4 (sensitivity of 79% and specificity of 86%). Twelve CD-US had HV stenosis confirmed by angiography. Mean HV1 and HV1/HV2: higher in the study group (HV1 = 202.2cm/s, HV1/HV2 = 6.0 / HV1 = 136.8cm/s, HV1/HV2 = 3.0) (p<.05). Statistical analysis determined as predictive of HV stenosis: PV1 > 128cm/s (sensitivity of 83% and specificity of 52%) and HV1/HV2 > 4 (sensitivity of 83% and specificity of 84%). CONCLUSION: PV diameter < 3.3mm at the anastomosis and HV1/HV2 > 4.0 are highly predictive for detection of PV and HV stenosis respectively, after pediatric segmental liver transplantation
18

"Importância da ecocardiografia com contraste por microbolhas em imagem fundamental na avaliação de pacientes sob ventilação mecânica no período pós-operatório de cirurgia cardíaca" / Contrast echocardiography can save non-diagnostic exams in mechanically ventilated patients

Joicely Melo da Costa 27 March 2006 (has links)
Estudou-se pela ecocardiografia em imagem fundamental, 30 pacientes no período pós-operatório de cirurgia cardíaca que encontravam se sob ventilação mecânica. Analisou-se o índice de escore de delineamento endocárdico (IEDE), a fração de ejeção do ventrículo esquerdo (FEVE) pelo método de estimativa visual, e os fluxos transvalvares pelo Doppler espectral e mapeamento de fluxo em cores antes e após a administração de um contraste ecocardiográfico a base de microbolhas. O IEDE passou de 1,53±0,63 para 2,01±0,56 após o uso do contraste (p < 0.001) e a FEVE pôde ser estimada em 27 de 30 exames após o uso do mesmo. Houve uma mudança na quantificação da insuficiência mitral em 5 exames, no gradiente de pico transvalvar aórtico em 1 paciente e no gradiente transvalvar de pico tricúspide em 8 pacientes / We studied by echocardiography in fundamental imaging (FI), thirty mechanically ventilated post cardiac surgery patients. LV endocardial border delineation score index (EBDSI), estimated left ventricular ejection fraction (LVEF) and color and spectral Doppler were analyzed before and after intravenous injection of ultrasound contrast. The use of contrast resulted in a significant increase in the number of well-delineated segments. EBDSI was 1.53±0.63, before contrast, increasing to 2.01±0.56 after it (p < 0.001). The LVEF could be evaluated in 27 of 30 exams after contrast. There was a change in the quantification of mitral regurgitation in 5 exams, in the aortic transvalvular peak gradient in 1 patient and measurement of peak flow velocity of tricuspid regurgitation in 8 patients
19

Avaliação da extensão da oclusão arterial na isquemia crônica de membros inferiores: estudo comparativo da ecografia com Doppler colorido e da arteriografia / Assessment of the arterial occlusion extension in the lower extremity chronic ischemia: a comparative study of the duplex ultrasound and the arteriography

Fidelis, Ronald José Ribeiro 07 November 2006 (has links)
A arteriografia é um exame radiológico invasivo que permite ver as características da luz das artérias tronculares e de pequenos ramos musculares e colaterais, tornando possível constatar alterações parietais mínimas através da injeção intravascular de meio de contraste. Apesar do grande desenvolvimento tecnológico que experimentou nas últimas décadas, tem limitações para definir a extensão da obstrução e o leito arterial pósobstrução na Doença Arterial Oclusiva de Membros Inferiores (DAO). Alguns estudos já analisaram a arteriografia quanto à visibilização do leito distal em pacientes com DAO femoropoplítea, porém nenhum estudou a extensão do segmento ocluído no território aortoilíaco utilizando a arteriografia intra-operatória com injeção distal de contraste como teste padrão. Este estudo clínico, prospectivo, conduzido no Serviço de Cirurgia Vascular do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, foi desenvolvido para avaliar a arteriografia pré-operatória em sua capacidade de detectar a real extensão das oclusões arteriais, e o leito arterial distal a estas. A Ecografia com Doppler colorido também foi avaliada nesses mesmos aspectos. A extensão da oclusão foi definida como sendo a distância entre o ponto de oclusão e o ponto de reenchimento (PR) da luz arterial, e o leito distal (LD) definido como o conjunto de todas as artérias que mantêm continuidade com este ponto de reenchimento. Todos os pacientes incluídos foram submetidos, em mesmo intervalo determinado de tempo, a uma Arteriografia com injeção de meio de contraste Proximal à obstrução (AP), uma Ecografia com Doppler colorido (Eco-Doppler) e ao padrão-ouro para diagnóstico do PR e LD, que é a Arteriografia com injeção de contraste Distal à obstrução (AD). Foram estudados 47 membros inferiores, de 33 pacientes. Trinta e quatro casos de doença aortoilíaca e 13 casos de doença arterial infrainguinal femoropoplítea. A AP detectou o verdadeiro PR em apenas 53,2% de toda a amostra, revelando uma reprodutibilidade ruim em relação à AD (k = 0,44, P < 0,001). Ao passo que o Eco-Doppler foi capaz de identificar o PR em 74,5% das vezes, revelando uma boa reprodutibilidade comparada ao teste padrão (k = 0,68, P < 0,001). Na visibilização do leito distal, a AP e o Eco-Doppler identificaram, respectivamente, 125 e 167 das 183 artérias vistas à AD. Esta diferença foi estatisticamente significativa (P = 0,001). Na análise da relação entre as variáveis estudadas e os resultados, o único fator significativamente associado com a discordância entre os métodos foi a localização anatômica da doença arterial. Com estes dados, concluí-se que a arteriografia préoperatória não identifica corretamente o PR e o LD em um número significativo de casos de DAO aortoilíaca. A Ecografia demonstrou neste estudo, uma concordância significativa com arteriografia intraoperatória, tanto na DAO aortoilíaca, quanto na femoropoplítea. / Arteriography is an invasive method of imaging the vascular system that allows assessment of the intraluminal characteristics of the arteries. It detects minimal arterial wall changes with intravascular injections of contrast agents. Dispite significant advances in lasts decades, some pitfalls remain in determining the extension of arterial occlusions and the run-off vessels in cases of arterial occlusive disease in the lower extremities (LEAOD). Some authors have already studied the extension of the disease, by arteriography, in patients with femoropopliteal disease; nevertheless, none of them has so far used the Intraoperative Distal Prebypass Arteriography (IDA) as the goldstandard in patients with disease in the aortoiliac territory. This study is a clinical, prospective trial, developed by the Division of Vascular Surgery at the University of Sao Paulo to analyse the pre-operative arteriography (POA) in its capacity of showing the true extension of the arterial occlusion and the run-off vessels in LEAOD. The Duplex Ultrasound Arterial Mapping (DUAM) was also tested in the same situations. Extension of the arterial occlusion was defined as the length between the point where the contrast agent leaves the main vessel, and the point where the contrast come back to it, in the arterial system, the later called Refilling Point (RP). Run-off was defined as the sum of the distal arteries continuous with the RP. All of the patients included in this study were subjected in a determined time interval to a POA, a DUAM and a IDA. Forty seven lower extremities were studied in 33 patients (34 with aortoiliac, and 13 with femoropopliteal disease). POA detected the true RP in 53% of the instances, with a bad reprodutibility of the gold-standard (k = 0,44, P > 0,001). The DUAM detected the RP 74,5%, with a good results reprodutibliity (k = 0,68, P < 0,001). In the assessment of run-off vessels POA and DUAM have detected, respectively, 125 and 167 of the 183 arteries showed in IDA. This disagreement between POA and DUAM was estastistically significant (P = 0,001). The only clinical characteristic associated with the results was the anatomical location of the arterial disease. We concluded that the POA does not identify the true RP and the run-off vessels in the aortoiliac LEAOD. The DUAM showed a good agreement with the IDA, and so it can be considered a good choice to assess the RP and the run-off in aortoiliac and femoropopliteal LEAOD.
20

Índice de performance miocárdica fetal na doença hemolítica perinatal / Myocardial performance index in alloimune disease

Assunção, Renata Almeida de 02 December 2015 (has links)
A hemólise decorrente da doença aloimune desencadeia mecanismos adaptativos hematológicos e hemodinâmicos fetais, com intuito de garantir o suprimento adequado de oxigênio para todos os tecidos e órgãos. Na anemia grave, a sobrecarga imposta ao coração fetal, devido ao fluxo hiperdinâmico, tem sido considerada responsável pela insuficiencia cardiaca, e posterior desenvolvimento de hidropisia fetal. No entanto, a literatura médica ainda apresenta controvérsias acerca da integridade da função cardiaca nesta doença. O índice de performance miocárdico (IPM) é uma ferramenta propedêutica não invasiva, derivada do Doppler pulsátil, que permite avaliar a função cardíaca global (sistólica e diastólica). Objetivo: Estudar a função cardíaca fetal, na doença aloimune, utilizando o índice de performance miocárdica. Métodos: Foram seguidos, prospectivamente, fetos únicos, de gestantes sensibilizadas pelo antígeno eritrocitário D, sem malformações estruturais, na Clinica Obstétrica, Hospital das Clinicas da Faculdade de Medicina de São Paulo. A cada avaliação ultrassonográfica, o IPM foi investigado por meio de Doppler pulsátil, com janela de 2-4mm, filtro>190Hz e velocidade de varredura que permitisse observar de 3 a 4 ciclos cardíacos simultâneos no ecrã. O IPM corresponde à soma dos tempos isovolumétricos (contração e relaxamento) dividido pelo tempo de ejeção do ciclo cardíaco. O IPM do ventrículo equerdo (IPM VE) foi realizado em ciclo único, sendo possível obter seus componentes: tempo de contração isovolumétrico (TCI), tempo de relaxamento isovolumétrico (TRI) e tempo de ejeção (TE). O IPM do ventrículo direito (IPM VD) foi obtido em dois tempos. Os valores obtidos de IPM VE, seus componentes foram convertidos em escore zeta para a idade gestacional. Frente à suspeita de anemia fetal, realizou-se cordocentese com determinação dos níveis de hemoglobina fetal antes e após a transfusão intra-uterina. Os respectivos valores foram convertidos em escore-zeta (Hb zeta). Na análise estatística, foram incluidas avaliações do IPM realizadas com menos de 72 horas antes, e até 24 horas após cada transfusão. Para cada transfusão foi calculada a variação no IPM (delta IPM = IPM antes - IPM após). O nível de significância estatísca adotado foi de 0,05. Análises por regressão linear simples e logística foram utilizadas para examinar a associação entre os valores de IPM e delta IPM e as seguintes variáveis: idade gestacional no procedimento, múltiplos da mediana (MoM) da Vmax ACM, Hb zeta pré e após TIU, volume de sangue transfundido e porcentagem da expansão do volume feto-placentário (EVFP). Resultados: Foram incluidas 14 gestações submetidas a 31 procedimentos de cordocentese para transfusão intra-uterina. A idade gestacional média na 1ª transfusão foi de 28,2 ± 4,1 semanas Em 6 procedimentos, a avaliação do IPM pós transfusional foi incompleta, e esses dados não foram incluídos na análise. Quanto à análise dos dados obtidos nas cordocenteses, observou-se correlação significativa entre os valores de escore zeta de IPM VE (r= 0,59, p <0,001), TRI (r= 0,45, p =0,01) e o TE (r= 0,42, p=0,2) e o escore zeta da hemoglobina fetal. Não foi observada correlação significativa com o escore zeta do TCI (r= 0,35, p=0,054) e do IPM VD (r=0,12, p= 0,53). Quando comparados aos valores observados antes das transfuões intra-uterinas, observou-se aumento significativo do escore zeta de IPM VE após os procedimentos (Delta MPI = 1,10 ± 2,47, p = 0,036). Não foi observada correlação entre os valores de escore zeta de IPM antes e após TIU. Delta MPI do VE se correlacionou inversamente, e de forma significativa, com a idade gestacional no procedimento (r= 0,47, p=0,018), escore zeta IPM VE pré-TIU (r= 0,50, p=0,012) e EVFP (r= 0,41, p=0,044). Conclusões: O desempenho miocárdico do ventriculo esquerdo fetal permanece preservado frente a anemia, e nos casos de anemia moderada e grave encontra-se ainda mais eficiente. Após a realização da transfusão intrauterina, observou-se aumento significativo do índice de performance miocárdica, e este aumento esteve relacionado com idade gestacional no procedimento, valores de IPM pré-transfusionais e a expansão do volume feto-placentário / Fetal anemia is associated with several adaptative mechanisms in order to maintain adequate tissue oxygenation. Circulatory changes play a key role in such circumstances. In severe anemia, the overload imposed on the fetal heart, due to the hyperdynamic flow, has been considered to be responsible for cardiac failure and finally hydrops fetalis. However, cardiac failure in this pathology remains controversy. Myocardial performance index (MPI) is a novel technique, Doppler derived and non-invasive that allows assesses global cardiac function (systolic and diatolic). Objective: Evaluate global cardiac function in alloimune disease through myocardial performance index. Methods: This prospective study was carried out at a tertiary referral center for fetal medicine (Clínica Obstetrica do Hospital das Clinicas da Faculdade de Medicina da Universidade de São Paulo). Women with singleton pregnancies and Rh D alloimmune disease were invited to take part in the study and gave informed consent. Fetal examinations did not show structural abnormalities. At every ultrasonography evaluation, MPI was examined with Doppler sample gate set between 2-4mm, wall motion filter >190Hz and high sweep-speed to allow simultaneous identification of 3-4 cardiac cycles on the screen. MPI is the sum of isovolumetric times (contraction and relaxation) divided by ejection time. Left ventricle MPI (LV MPI) was obtained in a single cycle and the MPI components were obtained: isovolumetric contraction time (ICT), isovolumetric relaxation time (IRT) and ejection time (ET). Right ventricle MPI (RV MPI) was obtained in two cycles. The values obtained for LV MPI and its components were converted in zeta score for gestacional age. Cordocentesis was perfomed if fetal anemia was suspicion and fetal hemoglobin levels were determined: before and after intrauterine transfusion. Hemoglobin values were converted into the zeta score (Hb zeta). Statistical analysis included MPI evaluations performed within less than 72 hours before and until 24 hours after every transfusion. Variation in the MPI was calculated for every transfusion (delta MPI = MPI before - MPI after). Significance level was set at 0,05. Linear and regression analyses were made in order to examine association between MPI values and delta MPI gestational age at procedure, fetal ACM multiples of median (MoM), Hb zeta before and after the IUT, volume of blood transfused and percentage of the feto-placental expansion volume (FPEV). Results: 14 pregnancies were included. Overall 31 cordocentesis for intrauterine transfusion were performed at mean gestational age of 28,2 ± 4,1 weeks. In 6 procedures, post transfusion MPI evaluation was incomplete and these data were not included in the analysis. Zeta-score values LV MPI (r= 0,59, p < 0,001), IRT (r= 0,45, p =0,01) and ET (r= 0,42, p=0,02) correlated significantly with fetal hemoglobin zeta score. Left ventricle ICT zeta-score (r= 0,35, p=0,054) and RV MPI (r=0,12, p= 0,53). did not show significant correlation. After intrauterine transfusion, LV MPI z-score ]increases and it was statistical significant (Delta MPI = 1,10 ± 2,47, p = 0,036). No correlation was observed between MPI zeta score values before and after the IUT. Delta LV MPI had inverse and significant correlation with pregnancy age in the proceedings (r= 0,47, p=0,018), LV MPI zeta score before IUT (r= 0,50, p=0,012) and FPEV (r= 0,41, p=0,044). Conclusions: Left ventricle myocardial performance not only remains preserved but is actually enhanced in cases of moderate/severe fetal anemia. After intrauterine transfusion procedure, left ventricle myocardial performance index increases significantly and greater changes are associated with procedures at earlier gestational age, lower pre transfusion MPI z-scores and smaller feto-placental volume expansion

Page generated in 0.3359 seconds