• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 134
  • 36
  • 9
  • 1
  • Tagged with
  • 186
  • 186
  • 67
  • 60
  • 43
  • 36
  • 33
  • 28
  • 27
  • 24
  • 23
  • 23
  • 21
  • 21
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Contribution à l'évaluation et à l'optimisation des application des systèmes microbio-électrochimiques : traitement des eaux, production d'électricité, bioélectrosynthèse / Contribution to the evaluation and optimisation of microbial electrochemical systems : wastewater treatment, electricity production, microbial electrosynthesis

Lapinsonnière, Laure 22 October 2013 (has links)
Les systèmes microbioélectrochimiques exploitent le métabolisme de microorganismes particuliers afin de catalyser des réactions d'oxydoréduction. Ces microorganismes organisés en biofilms à l'anode ou à la cathode sont en général des bactéries dites électroactives et peuvent être exploités dans une multitude d'applications. Une revue bibliographique des aspects fondamentaux et applicatifs de ce domaine est présentée. La génération d'électricité couplée à l'épuration d'eaux usées à l'anode de piles à combustible microbiologiques a été étudiée. Des bioanodes développées à partir d'acétate (substrat non fermentescible) sont capables de s'adapter et de dégrader le glucose et le lactose (substrats fermentescibles). Leur adaptation et leurs performances dépendent de la maturité du biofilm, du substrat et du renouvellement régulier de l'anolyte. Les propriétés physico-chimiques de la surface des électrodes ont été modulées afin de promouvoir la connexion de biofilms. A l'anode, nous avons étudié le greffage covalent d'acides phényle boroniques susceptibles de se complexer avec des glucides de la membrane externe des bactéries. Cette fonctionnalisation permet de réduire le temps de formation des biofilms et d'en améliorer les performances électriques sur graphite et sur nanotubes de carbone à parois multiples. A la cathode, les modifications de surface connues sur les bioanodes n'ont pas démontré d'influence sur les performances des biocathodes. Les différentes phases du développement de biocathodes catalysant la réduction du dioxygène à haut potentiel ont été étudiées. Le suivi de biocathodes réduisant le CO2 en acides organiques montre une production séquentielle d'acides organiques à chaîne aliphatique de plus en plus longue. / Microbial electrochemical devices use the metabolism of particular microorganisms to catalyze redox reactions. The microorganisms organized as biofilms onto anodes and cathodes are usually bacteria defined as electroactive and can be harnessed in electrochemical devices for several applications. A review of the fundamental and practical aspects of this field is presented. The simultaneous generation of electricity coupled to pollutant removal was studied at the anode of microbial fuel cells. Bioanodes developed with acetate (non-fermentable substrate) can adapt to the degradation of fermentable substrates (glucose and lactose). Their adaptation and performances depend on biofilm age, nature of the substrate and regular replacement of anolyte. The physico-chemical properties of electrode surfaces were tuned in order to promote microbial connection. At the anode, we investigated the covalent grafting of phenylboronic acids functionalities that are expected to bind with saccharides of the external membrane of bacteria. This functionalization leads to faster biofilm connection and higher performances of bioanodes on graphite and multi-walled carbon nanotubes. At the cathode, the grafting of chemical functionalities that already proved beneficial to bioanodes did not influence the performances of biocathodes. Different development phases of biocathodes catalyzing O2 reduction at high potential were studied. The monitoring of biocathodes catalyzing CO2 reduction showed a successive generation of organic acids with increasing aliphatic chain length.
112

Optimisation de la conception et du fonctionnement des stations de traitement des eaux usées / Optimization of the design and operation of wastewater treatment plants

Nguyen, Dinh-Huan 24 March 2014 (has links)
Ce travail de thèse constitue le prolongement direct des travaux de thèse Chachuat (2001) sur l'optimisation dynamique et la commande optimale des stations de traitement de petite taille. L'objectif est d'aller plus loin en s'intéressant aux dimensionnement et fonctionnement optimaux des stations de traitement des eaux usées de toute taille. Ainsi, dans une première étape, l'optimisation des stations de traitement de petite taille a été abordée. Contrairement à ce qui a été fait jusqu'à maintenant : (i) l'aération n'est plus alternée, mais continue, (ii) le décanteur n'est plus considéré comme parfait, mais son fonctionnement est modélisé à l'aide d'une série de 10 couches de décantation, (iii) la méthode d'optimisation développée est fondée sur la méthode des sensibilités implémentée au sein du logiciel de simulation et optimisation dynamiques gProms, utilisé dans toute la thèse. L'influence du modèle du décanteur sur la minimisation de l'énergie d'aération a été particulièrement analysée. Dans une deuxième étape, les stations de traitement de grande taille sont considérées. Plus spécifiquement, le modèle benchmark développé par le réseau européen COST a été utilisé pour décrire leur fonctionnement. Un « foreignobject » a été développé pour que la simulation et l'optimisation du fonctionnement de ces stations soient possibles sous gProms. L'optimisation a notamment montré que la consommation d'énergie d'aération pouvait être réduite d'au moins de 30% par rapport au fonctionnement actuel de ces stations. Dans une troisième étape, l'optimisation du dimensionnement des stations de traitement de grande taille a été étudiée. Une superstructure a ainsi été définie avec plusieurs (cinq) réacteurs et un décanteur. Toutes les possibilités de recyclage et de court-circuit entre les réacteurs d'une part et entre les réacteurs et le décanteur d'autre part sont prises en compte. L'objectif était de déterminer la meilleure structure et les valeurs optimales des volumes des réacteurs qui permettent de minimiser le coût total tout en respectant les contraintes réglementaires sur les rejets.Par ailleurs, une optimisation multicritère de la station optimale résultante a été réalisée. Elle a permis de déterminer l'ensemble de Pareto des solutions qui minimisent la consommation énergétique (d'aération et de pompage) et maximisent la qualité de l'effluent. La quatrième et dernière partie de ce travail s'intéresse à la modélisation, simulation et optimisation de la station de traitement de Verulam près de Durban en Afrique du Sud. Des mesures expérimentales ont été réalisées sur cette station et le modèle ASM1 a été utilisé pour décrire son fonctionnement. Une analyse d'estimabilité des paramètres a été d'abord réalisée pour déterminer les paramètres du modèle qui peuvent être estimés à partir des mesures expérimentales disponibles. Les paramètres estimables ont ensuite été identifiés à l'aide de gProms. Le modèle ainsi identifié a été validé et ensuite utilisé pour optimiser le fonctionnement énergétique de cette station / This work is a direct extension of the PhD thesis of Chachuat (2001) on dynamic optimization and optimal control of small size wastewater treatment plants. The objective is to go further by focusing on optimal design and operation of wastewater treatment plants of any size. Thus, in a first part, optimization of small size wastewater treatment plants was studied. Contrary to what has been done so far: (i) the aeration is no longer alternating, but continuous, (ii) the settler is not considered perfect, but its operation is modeled using a series of 10 sedimentation layers, (iii) the optimization approach developed is based on the method of sensitivities implemented wthin the dynamic simulation and optimization software gProms, used throughout this work. The influence of the settler model on the minimization of aeration energy was particularly investigated. In a second part , the large size treatment plants are considered . More specifically, the benchmark model developed by the European network COST was used to describe their operation. A "foreign object" was developed in order to make the simulation and optimization of these plants possible using gProms. The optimisation showed that the aeration energy consumption could be reduced by at least 30 % compared to the current operation of these plants . In a third part, the optimization of the design of the wastewater treatment plant was studied. A superstructure has been defined with several (five) reactors and a settler. All the possibilities of recycling and by-passes between the reactors on the one hand and between the reactors and the settler on the other are considered. The objective was to determine the best structure and the optimal values of the reacter volumes that minimize the net present value while respecting the regulatory constraints. On the other hand, a multi-objective optimization problems of the treatment plant was carried out. It allawed to determine the Pareto set of solutions that minimize the energy consumption (pumping and aeration) and maximize the effluent quality. The fourth and last part of this work focuses on modeling, simulation and optimization of the treatment plant of the city of Verulam in the area of Durban in South Africa. Experimental measurements were carried out on the plant and the ASM1 model was used to describe its operation. An estimability analysis was first performed in order to determine the model parameters that can be estimated from the available experimental measurements . The estimable parameters were then identified using gProms . The identified model was validated and then used to optimize the energy function of this plant
113

Étude expérimentale et théorique du procédé d'électrocoagulation : application au traitement de deux effluents textiles et d'un effluent simulé de tannerie / Experimental and theoretical investigations of electocoagulation (EC) process : application to the treatment of two textiles effluents and simulated tannery effluent

Zongo, Inoussa 03 November 2009 (has links)
L’électrocoagulation est une technique de traitement des eaux usées basée sur la dissolution d’anode sacrificielle de fer ou d’aluminium. Ces métaux se dissolvent sous formes de cations Fe2+ puis Fe3+ et Al3+ qui vont former des hydroxydes de métal qui entraînent par adsorption les impuretés de l’effluent en diminuant le potentiel Zêta de ces impuretés. Le réacteur électrochimique utilisé est constitué de deux électrodes métalliques (Fe ou Al) planes et parallèles qui laissent passer entre elles l’effluent à traiter. Des densités de courant de 50 à 200 A/m2 ont été appliquées pour traiter les trois effluents. L’un est un effluent directement issu d’une usine textile (effluent « usine »). Un second provient du flux d’entrée de la station d’épuration du site qui collecte les effluents de plusieurs usines (effluent « station »). Le troisième est un effluent artificiel de tannerie, créé en ajoutant 200 ppm de chrome VI à l’effluent « station ». Pour chaque expérience, la densité de courant et le temps de traitement vont déterminer la charge électrique et la concentration en métal dissous atteinte. L’influence de ces quatre paramètres sur l’élimination de la DCO, de l’absorbance, de la turbidité, du COT et du chrome hexavalent a été étudiée. L’évolution au cours du temps d’autres paramètres de l’EC tels que le pH, la tension, le rendement faradique et la dissolution métallique ont été étudiés afin de comprendre leur rôle dans le procédé. Le traitement a permis d’avoir un abattement maximal de DCO de 82% et 80% pour l’effluent « station » traité respectivement avec les électrodes de fer et d’aluminium ; 75 et 67% pour l’effluent « usine » traité respectivement avec les électrodes de fer et d’aluminium. L’abattement du chrome est de 100% avec les électrodes de fer mais tombe à 70% avec celles en aluminium. Des modèles d’élimination de la DCO et de l’absorbance ont été établis pour chaque matériau d’électrode utilisé. Le modèle d’élimination du chrome VI a été établi à partir du traitement avec les électrodes de fer. Une étude de la spéciation des espèces a permis de déterminer les pH optimaux de coagulation-floculation pour chaque métal impliqué (Al, Fe, Cr). La compétitivité entre l’abattement de la pollution organique et du Chrome a aussi été étudiée pour chaque type d’électrode / Electrocoagulation (EC) is a water treatment technology that relies on the electrochemical sacrificial anodes (in Fe or Al) dissolution. This metal dissolve themselves in Al3+ and Fe2+ cations that later oxidise to Fe3+ ions. These cations form metal hydroxides that adsorb the impurities of the effluent while decreasing the zeta potential. The electrochemical reactor used consists on two plane parallel metal electrodes with recirculation of the effluent to be treated between them. Current densities from 50 to 200 A/m2 were imposed to treat each effluent. Three effluents were used in this study. The first one is an effluent sampled at the outlet of a textile plant (« plant »). The second one is a mixture of several effluents coming from different plant and collected at the inlet of the wastewater treatment (« treatment plant »). The last one is a wastewater tannery plant simulated by addition of 200 ppm Chromium VI in the treatment plant effluent. For each experience the current density and the time of treatment rule the electrical charge and the concentration in dissolved metal reached. The influence of these four parameters on the elimination of COD, absorbance, turbidity, COT and hexavalent chromium content has been studied. Parameters e.g. potential, faradic yield, metal dissolution and pH have also been continuously monitored to better understand their role on EC process. The results show that DCO abatement reached 80 and 82% for treatment plant effluent, respectively with iron and aluminium electrodes; and 75 and 67% for plant effluent, respectively with iron and aluminium electrodes. The chromium treatment yields 100 % abatement with Fe electrodes whereas it is only 70% using Al electrodes. Models have been developed for COD and absorbance removal for the two electrode materials. Model for chromium (VI) treatment has been established considering all reactions occurring for iron EC. Metal speciation study allowed us to determine the optimal pH of coagulation –flocculation for each metal involved in the treatment (Al, Fe, Cr). Competition between organic pollution removal and chromium elimination has been also investigated for each electrode material
114

Consortium algues-bactéries des lagunes à haut rendement algal : évaluation des performances, devenir des nutriments des eaux usées et conception à base de modèles expérimentaux et numériques / Algal-bacterial consortium in high rate algal pond : evaluation of performances, wastewater nutrient recovery and experimental and numerical models based design

Pham, Le Anh 13 September 2018 (has links)
La présente thèse porte sur des travaux expérimentaux et de modélisation visant à étudier les processus bactériens et algaux au sein d’une lagune a haut rendement algal (HRAP). Un système pilote HRAP a été construit et les impacts des différentes conditions opérationnelles sur l’hydrodynamique et le transfert gaz/liquide du pilote ont été étudiés. De plus, le rapport d'inoculation optimal entre les algues et les bactéries (Al-Bac) a également été étudié. La biomasse Al-Bac a ensuite été inoculée dans le système HRAP pour une évaluation à long terme du traitement des eaux usées et de la récupération des nutriments. Le HRAP dans cette étude peut être appliqué en traitement secondaire de eaux usées ou comme étape primaire éliminant rapidement les charges élevées de DCO et de TKN des retour en tête de digesteurs anaérobies (centrats). Les résultats expérimentaux obtenus ont également été utilisés pour calibrer et valider des modèles de type « boîte noire » et mécanistes. Les deux modèles peuvent décrire le fonctionnement à long terme du système. Le premier permet ainsi d'évaluer rapidement les performances du système ainsi que de le dimensionner, tandis que le second simule avec succès les résultats à long (général) et à court (détaillé) terme. L'étape suivante devrait être l'application du système à grande échelle. / The thesis focused on both experimental and modeling works aiming to investigate the algal bacterial processes in High-Rate Algal Pond (HRAP) system. A pilot HRAP system was built and the impacts of different operational conditions on hydraulic and gas transfer rate of the pilot were investigated. Moreover, optimal inoculation ratio between algae and bacteria (Al-Bac) was also studied. The Al-Bac biomass was theninoculated in the HRAP system for long term assessment of wastewater treatment and nutrient recovery. The HRAP in this study can be applied for secondary treatment application or as a primary step removing rapidly high loads of COD and TKN from centrate wastewater. Experimental results obtained were also employed in calibrating and validating black box and comprehensive algal bacterial models. Both models coulddescribe the system in long term. The former was adequate for giving quick assessment of the system performance as well as sizing application while the latter successfully simulated the results both in long (general) and short (detailed) time scale. A next step should be applying the system in large scale.
115

Devenir des virus entériques de l'homme dans les eaux et les sols : vers une comparaison de scénarios de rejets et de recyclages / Fate in soil of murine Norovirus : used as a surrogate for human norovirus present in wastewater reused in agricultural irrigation

Tesson, Vincent 14 March 2018 (has links)
Les eaux usées traitées d'origine domestique présentent généralement une charge non négligeable en virus entériques pathogènes de l'Homme, malgré leur traitement. Afin de pouvoir à terme comparer les risques sanitaires associés à différents modes de gestion de ces eaux usées, nous avons entrepris un travail sur (i) la prévision des quantités de virus entériques excrétés à partir des données épidémiologiques relatives aux gastroentérites aiguës, (ii) le devenir environnemental de ces virus lorsque les eaux usées sont rejetées en rivière, et (iii) le devenir de ces virus lorsqu'ils sont apportées au sol par irrigation. L'étude a porté sur un bassin de collecte des eaux usées de 240 000 habitants à proximité de Clermont-Ferrand, sur les rivières Artière et Allier et la nappe alluviale de l'Allier potentiellement contaminées par les rejets d'eau usée, et sur un sol du périmètre d'irrigation réutilisant ces eaux. Les concentrations en divers virus ont été suivies sur la même période dans les eaux usées brutes et traitées, dans les eaux douces de surface et souterraine. Nous avons proposé une méthode d'estimation du nombre journalier de nouveaux cas de gastroentérites aiguës d'étiologie virale en 2015-2016 à partir de données épidémiologiques et avons combiné ces estimations à un modèle d'excrétion virale pour évaluer les quantités de virus entériques arrivant à la station d'épuration. Le devenir des virus a été modélisé en tenant compte d'un abattement en station d'épuration et de dilutions-mélanges en rivières. Le devenir des virus apportés au sol par les eaux usées traitées réutilisées en irrigation agricole a été étudié sur un sol bien représenté dans le périmètre en utilisant un virus modèle. Ce devenir a été décrit par un modèle combinant transfert, immobilisation réversible et élimination, et en distinguant eau mobile et eau immobile comme virus libres et virus adsorbés sur des colloïdes en suspension. La méthode permettant de passer de l'épidémiologie à une excrétion de virus nous a permis de bien simuler les arrivées de virus à la station d'épuration avec un pic hivernal et l'impact prépondérant des norovirus GII sur les cas de gastroentérites virales. La simulation de l'abattement en station d'épuration et des phénomènes de dilutions-mélanges en rivière permet de simuler correctement la charge virale en aval du rejet d'eaux usées, mais leur devenir ultérieur reste mal caractérisé. Apporté au sol, le virus modèle était progressivement éliminé ou immobilisé de façon irréversible avec un abattement journalier de 0.38 log10. La fraction réversiblement immobilisée pouvait être estimée par une isotherme de Freundlich. L'ajout de Mg2+ a favorisé l'immobilisation du virus comme son adsorption sur des colloïdes dispersés dans l'eau mobile. Alors que les eaux usées stérilisées n'avaient pas d'effet majeur sur l'immobilisation du virus par rapport à une solution artificielle de sol en raison d'effets antagonistes des composés organiques et des cations minéraux, l'eau souterraine riche en Mg2+ favorisait l'immobilisation des virus. Un volet plante réalisé en marge de ce travail a montré l'impact d'irrigations sur les contaminations de surface et après internalisation via les racines. Complétée et améliorée, notre étude pourrait être couplée à une évaluation quantitative des risques viraux. / Urban treated wastewaters may be heavily contaminated by human pathogenic enteric viruses that cause acute gastroenteritis, despite their treatment. In order to compare health risks of different wastewater management scenarios, we investigated (i) how to predict virus shedding from epidemiological data on acute gastroenteritis, (ii) the environmental fate of these viruses when wastewaters are discharged into rivers, and (iii) the fate of these viruses when they are brought to the soil by irrigation. Our study focused on a wastewater collection basin of 240,000 inhabitants near Clermont-Ferrand, on the Artière and Allier Rivers and the Allier alluvial groundwater potentially contaminated by wastewater discharges, and on a soil in the irrigation perimeter reusing these wastewaters. Concentrations of various viruses were monitored over the same period in raw and treated wastewaters, as well as in surface and underground freshwaters. We proposed a method based on epidemiological data to estimate the daily number of new cases of acute gastroenteritis of viral etiology in 2015-2016; and we combined these estimates with a viral shedding model to estimate the quantities of enteric viruses arriving at the treatment plant. The fate of viruses has been simulated by taking into account the removal of viruses in the treatment plant and dilution-mixing in rivers. The fate of viruses brought to the soil by treated wastewater reused in agricultural irrigation was studied on a well-represented soil in the perimeter using a surrogate virus. Its fate has been described by a model combining transfer, reversible immobilization and removal; the model distinguished between mobile and immobile waters, as well as between free viruses and viruses adsorbed on colloids in suspension. The method for switching from epidemiology to virus shedding allowed us to accurately simulate virus inflows to the treatment plant, including a winter peak and the prominent role of norovirus GII in viral gastroenteritis cases. The simulation of virus removal in the treatment plant and subsequent dilution-mixing phenomena in rivers allow correctly simulating the viral load in the river downstream of the wastewater discharge, but their subsequent fate remains poorly characterized. When brought to the soil, the surrogate virus was progressively removed or irreversibly immobilized, according to a 0.38 log10 daily removal. The reversibly immobilized fraction could be estimated by a Freundlich isotherm. The addition of Mg2+ favored the immobilization of viruses, as well as their adsorption on colloids dispersed in mobile water. While sterilized wastewater had no major effect on virus immobilization compared to artificial soil solution due to the antagonistic effects of their organic compounds and mineral cations, groundwater rich in Mg2+ favored immobilization of viruses. An additional work, complementary to this PhD, showed the impact of irrigations on vegetable surface and internalized contaminations. After improvement, our study could be coupled with a quantitative viral risks assessment.Key words: enteric virus, sewage, discharge, reuse, irrigation, environmental fate, scenarios, assessment,
116

Résidus de médicaments d'un cours d'eau urbain : constitution d'une base de données pour la gestion des risques écotoxicologiques / Drug residues in urban water : a database for ecotoxicological risk management

Destrieux, Doriane 28 March 2018 (has links)
Les Résidus de Médicaments (RM) sont des molécules biologiquement actives et leur présence dans l'environnement peut induire des effets sur les écosystèmes. Afin de caractériser l'impact écotoxicologique lié à l'utilisation de ces molécules dans la région toulousaine, 26 RM ont été recherchés dans les eaux usées de deux Stations de Traitement des Eaux Usées (STEU) de la ville de Toulouse et dans le milieu récepteur de leurs rejets, la Garonne. Dans la Garonne, les prélèvements ont été réalisés en amont et en aval des effluents des STEU afin d'étudier l'impact de ces effluents sur le risque associé à la présence de ces RM dans le fleuve. Le risque écotoxicologique potentiel a été évalué en comparant, pour chacun des RM étudiés, les concentrations mesurées in situ (exposition) et les concentrations écotoxiques (danger). Ces comparaisons ont permis la définition de quotient de risque (RQ) en fonction du temps et de l'espace. Les résultats des analyses ont montré que, malgré le fait que la plupart des molécules soient détectées dans la Garonne en amont des rejets des STEU, certains RM ont présenté des concentrations significativement plus importantes dans la Garonne en aval des rejets. Ces résultats soulignent l'impact des effluents toulousains sur le risque associé à la la présence de RM dans la Garonne. Dans le cadre de ces travaux de recherches une base de données (BDD) a été développée qui intègre 1/ des données d'écotoxicité issues de la littérature scientifique (1237 données issues de bio-essais, modélisations et bio-marqueurs et 382 Predicted No Effect Concentrations (PNEC)) ; 2/ des données d'exposition à l'échelle de l'agglomération toulousaine (125 échantillons récoltés). L'étude des RQ, à partir des plus basses PNEC actuellement disponibles dans la BDD, a montré des risques écotoxicologiques potentiels liés à la présence de 7 RM dans la Garonne sur les 26 recherchés. Ces 7 RM sont, dans l'ordre décroissant des pourcentages d'occurrence des risques associés, Carbamazépine (anti-épileptique) (100%), Clarithromycine (100%), Diclofénac (anti-inflammatoires non stéroïdiens (AINS)) (100%), Estrone (hormone sexuelles) (100%), Ofloxacine (antibiotiques) (93%), Ibuprofène (AINS) (62%) et Propranolol (cardiovasculaire) (31%). L'étude des concentrations écotoxiques inclues dans la BDD ont montré des variabilités intramoléculaires importantes. Pour l'évaluation des risques environnementaux (ERE), la réglementation européenne recommande d'utiliser une seule donnée d'écotoxicité pour définir le seuil toxique requis pour l'ERE (PNEC). Ces variabilités intramoléculaires démontrent que le déploiement de la démarche proposée par la réglementation pour l'ERE peut générer une sous-estimation des risques écotoxicologiques. De plus, la variabilité temporelle des données d'exposition engendre, pour les 7 RM identifiés comme potentiellement dangereux, 1/ l'alternance des périodes à risque et à non risque pour le Ibuprofène, Ofloxacine et Propranolol; 2/ des risques avérés quelle que soit la période considérée pour la Carbamazépine, Clarithromycine, Diclofénac et Estrone. Ces résultats suggèrent que, la variabilité des concentrations, qu'elles soient prédites (PEC) ou mesurées (MEC), doit être prise en compte pour mesurer l'impact de la présence de RM sur les écosystèmes aquatiques. Avec un meilleur accès aux soins de santé et une population vieillissante menant à une poly-médication, la production, l'utilisation et l'élimination des produits pharmaceutiques devraient augmenter. De par le rôle des médicaments dans la santé publique et les impacts potentiels sur les écosystèmes, cette problématique associée à la présence de RM dans les milieux aquatiques doit être prise en charge par une action concertée afin de prévenir, réduire et gérer l'introduction des RM dans l'environnement. / Drug residues (DR) are biologically active molecules and their environmental occurrence can produce negatives effects on the ecosystems. In order to identify the ecotoxicological impact linked to their use in the Toulouse area, 26 DR were searched in two waste water treatment plant (WWTP) of Toulouse, inlet and outlet, and into the natural water receiving the WWTP releases, the Garonne river. In the Garonne river, sampling were carried out upstream and downstream of WWTP outlets in order to study impact of their releases on the ecotoxicological risks linked to the DR occurrence in the river. Ecotoxicological risks were estimated with the ratio between measured environmental concentrations (exposure) and environmental hazard threshold (hazard) for each drug. These ratios allowed to define hazard quotients (HQ) according to time and space. Despite the fact that most of DR were detected in the Garonne upstream of WWTP releases, some of them showed significant greater concentrations downstream the WWTP releases. For these last ones, results highlight that WWTP releases are responsible for the ecotoxicological risks linked to the presence of DR in the Garonne river. As part of this study, a database was made, including 1/ ecotoxicity data coming from scientific literature (1237 data provided from bioassays, modellings and biomarkers and 382 Predicted No Effect Concentrations (PNEC)); 2/ exposition data from Toulouse city (125 collected samplings). Since the lowest PNEC available in the database, the HQ study showed ecotoxicological risks linked to the occurrence of 7 DR in the Garonne among the 26 searched. In the decreasing order of the risks percentage occurrence, these 7 DR are Carbamazepine (antiepileptic) (100%), Clarithromycin (antibiotic) (100%), Diclofenac (non-steroidal anti-inflammatory drug (NSAID)) (100%), Estrone (sexual hormone) (100%), Ofloxacin (antibiotic) (93%), Ibuprofen (NSAID) (62%) and Propranolol (cardiovascular) (31%). The ecotoxicity concentrations integrated in the database showed important intra-molecular variabilities. For environmental risk assessment (ERA), european regulation recommends to use only one ecotoxicity data to define the environmental threshold required for the ERA (PNEC). These intra-molecular variabilities demonstrate that implementation of the ERA process proposed by regulation could create under-estimations of the ecotoxicological risks. Moreover, exposure data temporel variability for the 7 DR identified as potentially hazardous causes 1/ alternation of risked and non-risked periods for Ibuprofen, Ofloxacin and Propranolol; 2/ proven risks whatever the considered period for Carbamazepine, Clarithromycin, Diclofenac and Estrone. These results suggest that concentrations variability, whether predicted (PEC) or measured (MEC), should be taken into account to assess the DR impact on the aquatics ecosystems. With better access to health care and an ageing population leading to a multiple medication, the production, the use and the pharmaceuticals elimination should increase. Because of their role in the public health and their potential impact on the ecosystems, the presence of DR in the aquatic environments is an issue that should be taken in hand by a concerted action in order to prevent, reduce and manage DR release in the environment.
117

Contribution à l’étude de l’électro-compression des boues résiduaires urbaines / Contribution to the study of electro-compression of urban sewage sludge

Jean-Baptiste, Conrardy 18 December 2014 (has links)
Dans une problématique de réduction des volumes de déchet, l’électro-compression (ou électro-déshydratation) apparaît être une technique efficace pour éliminer une grande partie de l’eau des boues résiduaires urbaines. Cette thèse de doctorat présente différentes contributions à l’étude de ce procédé appliqué à ce type de boues. Un lien entre les données cinétiques et énergétiques est établi par une étude expérimentale à l’échelle du laboratoire. D’autre part, un nouveau modèle relativement simple est proposé pour l’étude et la simulation de l’électro-compression et permet de mettre en avant les phénomènes prépondérants. Enfin, un protocole d’analyse ionique des filtrats et des tranches de gâteaux de boue a permis une étude de la migration des espèces chimiques au cours de l’électro-déshydratation. / In the purpose to reduce waste amount, the electro-dewatering process is a promising technique to efficiently withdraw a large part of the water included in wastewater sludge. This PhD thesis contributes in various ways to the study of this technique. Lab-scale experiments showed correlations between dewatering kinetics and energy consumption of the process. Moreover, a new model, relatively simple, is proposed to study and simulate the process. This model highlights the main phenomena involved in the electro-dewatering. Finally, a study of the migration of chemical species during the dewatering process is carried out thanks to an analytical protocol measuring ions in filtrates and sludge slices.1
118

Des propriétés morphologiques des flocs biologiques aux conditions de fonctionnement de systèmes à boues activées / From the morphological properties of biological flocs to the operating conditions of activated sludge systems

Oliveira, Pedro 06 July 2018 (has links)
Parmi les différentes technologies pour produire un effluent conforme aux normes de rejet en vigueur, les Procédés par Boues Activées sont largement utilisés en tant que traitement biologique du fait de leur faible coût et de leur facilité d’implémentation. Ces procédés réalisent l’abattement des polluants en deux étapes : (1) la biodégradation par des microorganismes dans un bassin d’aération et (2) la séparation de la biomasse par décantation. Les paramètres opératoires peuvent agir sur l’efficacité du procédé, notamment en modifiant les propriétés des boues . L’objectif de ce travail est d’apporter un nouvel éclairage sur cette relation triangulaire en mettant en perspectives les propriétés de taille et de forme des flocs de boues et les performances du procédé de traitement. La première étape pour parvenir à cet objectif a consisté à développer une méthodologie de caractérisation des flocs de boues par analyse d’images à l’aide du microscope automatisé Morphologi G3 de Malvern Instruments. Le protocole de mesure proposé repose sur le choix de la cellule d’analyse, du facteur de dilution, du grossissement, du seuil de niveau de gris mis en œuvre pour la binarisation des images et du nombre total de particules analysées. Des boues provenant de plusieurs stations d’épuration ont été étudiées afin d’évaluer la robustesse de la méthodologie. Des différences en termes de propriétés de taille et forme - Diamètre équivalent (Deq), Circularité (C), Convexité (Cx), Solidité (S) et Rapport d’Aspect (RA) - entre les différentes boues sont clairement apparues. Le protocole de caractérisation de la morphologie étant établi et validé, deux campagnes expérimentales ont été mises en œuvre en utilisant un système à boues activées à l’échelle pilote alimenté par un effluent synthétique. Les descripteurs morphologiques ont été mesurés sur des échantillons d’environ 100 000 flocs permettant d’atteindre une statistique fiable aussi bien sur la taille que sur la forme des agrégats. La performance du procédé a été évaluée en suivant des indicateurs physicochimiques classiquement associés au traitement des eaux usées : Matières en Suspension (MES), Indice de Boue (IB), taux d’abattement de la Demande Chimique d’Oxygène (DCO) et de l’Azote (N). Cette stratégie a permis d’identifier des relations entre les performances d’épuration, la morphologie des agrégats et les paramètres opératoires. Pendant la première campagne, trois valeurs différentes de l’âge de boue ont été imposées : 15, 20 et 30 jours. Lors d’un changement d’âge de boue, la taille et la circularité des flocs biologiques augmentent temporairement avant de se stabiliser à nouveau à leurs valeurs initiales. Ainsi, en régime permanent, les distributions en taille et en circularité semblent indépendantes de l’âge de boue. Lors de la deuxième campagne, trois paramètres opératoires ont été modifiés : la charge organique, le taux de recirculation et le rapport DCO:N. Une charge organique élevée a provoqué une forte augmentation de la taille des flocs et une diminution de leur solidité. Ce résultat peut être expliqué par la croissance de bactéries filamenteuses qui impacte fortement la morphologie des flocs et la performance du procédé. L’augmentation du taux de recirculation et la diminution du rapport DCO:N ont, en outre, induit une légère réduction de la taille des flocs et une évolution peu significative des valeurs de circularité et convexité. L’analyse des distributions en 3 Dimensions couplant les données de taille et de forme s’est révélée un outil prometteur, permettant de proposer des mécanismes responsables de l’évolution des propriétés morphologiques des boues. Enfin, une autre approche a été développée sur la base de deux dimensions fractales reliant l’aire et le périmètre des flocs (Dpf) ou l’aire et la longueur maximale (D2). De brusques variations de Dpf et D2 ont été corrélées avec les phénomènes liés au développement de bactéries filamenteuses. / Among the different technologies dealing with the strict regulations concerning wastewater treatment, the Activated Sludge Process remains extensively applied as a biological treatment because of its low cost and its convenience of implementation. This straightforward technique achieves good levels of organic matter removal combining biodegradation in an aerated tank with solid-liquid separation through a subsequent clarifier. The impact of the operational parameters on process efficiency is presumably correlated to the sludge activity and hence to the flocs properties. In this context, the aim of this work is to bring new insights into this relationship in characterizing the size and the shape of sludge flocs and put the operating conditions and the process performance in perspective. To achieve this objective, a methodology was established first for the morphological characterization of sludge flocs by image analysis thanks to the automated microscope Morphologi G3 from Malvern Instruments Ltd. The steps involved in this methodology consisted in defining some analysis settings including the selection of the sample carrier, the dilution factor, the magnification, the threshold needed for the image binarization and the total number of analysed particles. Analyses were performed on various types of sludge allowing an evaluation of the methodology robustness. Differences clearly appeared in terms of size and shape properties – Circular Equivalent Diameter (CED), Circularity (C), Convexity (Cx), Solidity (S), and Aspect Ratio (AR) between the different types of sludge. The image analysis protocol having been established and validated, two experimental campaigns were run using a lab-scale activated sludge system fed with synthetic wastewater. The morphological descriptors were defined on the base of about 100,000 sludge flocs per sample allowing to reach reliable statistics for both size and shape properties. Process performance was assessed measuring physicochemical parameters commonly associated with wastewater treatment: Total Suspended Solids (TSS), Sludge Volume Index (SVI), Chemical Oxygen Demand (COD) and Nitrogen (N) removal. This strategy has mostly enabled to identify relationships between the treatment performance, the floc morphology and the operating conditions. During the first campaign, three values of solids retention time (SRT) were tested: 15, 20 and 30 days. Increasing the SRT, the size and the circularity of the flocs increased temporarily before recovering their initial values. Under steady state conditions, the size and circularity distributions seem thus to be independent of the SRT. In the second campaign, three operating conditions were modified in turn: the Organic Load Rate (OLR), the recycle rate and the COD:N ratio. A high OLR has promoted a strong increase of flocs size and the decrease of their solidity. This result can be explained by the development of filamentous bacteria that highly impacts the aggregates morphology and hence the process performance. An increase of the recycle rate or a decrease of the COD:N ratio induced a slight reduction of floc sizes and an insignificant evolution of circularity and convexity values. The analysis of the volume-based 3D-distributions crossing size and shape data appeared as a smart tool allowing to propose mechanisms responsible of the changes of the morphological properties of biological flocs. Finally, another approach was developed, based on the estimation of two 2D fractal dimensions linking the area and the perimeter of flocs (Dpf) or the area and the maximum length (D2). Sudden changes of Dpf and D2 were correlated to phenomena related to the presence of filamentous bacteria.
119

Estimation de l'état des systèmes non linéaires à temps discret. Application à une station d'épuration

Boulkroune, Boulaïd 14 November 2008 (has links) (PDF)
Ce sujet de recherche revêt, d'une part, un caractère théorique puisqu'il aborde le problème d'estimation des systèmes singuliers linéaires et non linéaires à temps discret pour lesquels très peu de résultats sont disponibles et, d'autre part, un aspect pratique, car le modèle utilisé est d'une station d'épuration des eaux usées à boues activées. Dans la partie théorique, nous nous sommes intéressés, dans un premier temps, à l'estimation d'état des systèmes singuliers linéaires en utilisant l'approche d'estimation à horizon glissant. Deux estimateurs optimaux, au sens des moindres carrés et au sens de la variance minimale, ont été présentés. L'analyse de la convergence et de la stabilité de ces estimateurs est traités. Ensuite, nous avons présenté une approche pour l'observation de la classe des systèmes non linéaires lipschitziens à temps discret. En supposant que la partie linéaire de cette classe de systèmes est variante dans le temps, le problème de l'estimation d'état d'un système non linéaire est transformé en un problème d'estimation d'état d'un système LPV. La condition de stabilité de l'observateur proposé est exprimée en terme d'inégalités matricielles linéaires (LMI). Enfin, dans la partie pratique, les résultats obtenus sont validés par une application à un modèle d'une station d'épuration des eaux usées à boues activées.
120

Variabilité spatiale des caractéristiques et des origines des polluants de temps de pluie dans le réseau d'assainissement unitaire parisien

Kafi-benyahia, Mounira 03 1900 (has links) (PDF)
Ce travail de thèse s'inscrit dans le cadre de l'OPUR: "Observatoire des Polluants Urbains en Ile de France". Il s'appuie sur la mise en place d'un dispositif expérimental sur une série de six bassins versants de taille croissante et de d'occupation du sol comparable, allant du bassin du Marais (41 hectares) jusqu'au site de Clichy (2500 hectares) en suivant l'axe du collecteur de Clichy, à Paris. Ce dispositif a permis : - d'étudier la variabilité des flux et de la nature des polluants transférés par temps sec et par temps de pluie, dans les réseaux d'assainissement unitaires, en fonction des caractéristiques et de l'échelle spatiale des bassins versants. Le travail porte notamment sur : - Concentrations moyennes et flux des MES, MVS, DCO, DBO5, COT, NTK et des métaux lourds Cd, Cu, Pb et Zn. - Nature des polluants: répartition dissous-particulaire, teneurs en polluants et vitesses de chute des particules. - de comprendre le fonctionnement hydrologique et hydraulique du réseau d'assainissement des bassins versants OPUR et d'étudier les mécanismes de transfert dans les réseaux unitaires. - d'évaluer la contribution des trois sources "Eaux usées, Eaux de ruissellement et Stocks de dépôt dans le réseau" aux flux polluants de temps de pluie. Cette évaluation a été faite en utilisant une approche de bilan de masse entre l'entrée et la sortie de chaque bassin versant. Les résultats obtenus indiquent d'une part, une relative homogénéité des flux polluants, de leur nature et des processus dominants sur les six bassins versants étudiés. Ils montrent d'autre part une importante contribution de l'érosion des stocks constitués dans le réseau d'assainissement aux flux des matières en suspension, des matières organiques, du cuivre total, quelque soit la taille du bassin versant. Cette contribution varie, en moyenne, selon le site de mesure, entre 49 et 70% pour les MES, et entre 43 et 71% pour le cuivre total. Pour le cadmium, le plomb et le zinc, les eaux de ruissellement s'avèrent être la source principale.

Page generated in 0.0662 seconds