• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 34
  • 28
  • 5
  • 4
  • 3
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 97
  • 97
  • 97
  • 29
  • 24
  • 24
  • 16
  • 14
  • 11
  • 11
  • 10
  • 9
  • 9
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Sensitivity Analysis and Material Parameter Estimation using Electromagnetic Modelling / Känslighetsanalys och estimering av materialparametrar med elektromagnetisk modellering

Sjödén, Therese January 2012 (has links)
Estimating parameters is the problem of finding their values from measurements and modelling. Parameters describe properties of a system; material, for instance, are defined by mechanical, electrical, and chemical parameters. Fisher information is an information measure, giving information about how changes in the parameter effect the estimation. The Fisher information includes the physical model of the problem and the statistical model of noise. The Cramér-Rao bound is the inverse of the Fisher information and gives the best possible variance for any unbiased estimator. This thesis considers aspects of sensitivity analysis in two applied material parameter estimation problems. Sensitivity analysis with the Fisher information and the Cramér-Rao bound is used as a tool for evaluation of measurement feasibilities, comparison of measurement set-ups, and as a quantitative measure of the trade-off between accuracy and resolution in inverse imaging. The first application is with estimation of the wood grain angle parameter in trees and logs. The grain angle is the angle between the direction of the wood fibres and the direction of growth; a large grain angle strongly correlates to twist in sawn timber. In the thesis, measurements with microwaves are argued as a fast and robust measurement technique and electromagnetic modelling is applied, exploiting the anisotropic properties of wood. Both two-dimensional and three-dimensional modelling is considered. Mathematical modelling is essential, lowering the complexity and speeding up the computations. According to a sensitivity analysis with the Cramér-Rao bound, estimation of the wood grain angle with microwaves is feasible. The second application is electrical impedance tomography, where the conductivity of an object is estimated from surface measurements. Electrical impedance tomography has applications in, for example, medical imaging, geological surveillance, and wood evaluation. Different configurations and noise models are evaluated with sensitivity analysis for a two-dimensional electrical impedance tomography problem. The relation between the accuracy and resolution is also analysed using the Fisher information. To conclude, sensitivity analysis is employed in this thesis, as a method to enhance material parameter estimation. The sensitivity analysis methods are general and applicable also on other parameter estimation problems. / Estimering av parametrar är att finna deras värde utifrån mätningar och modellering. Parametrar beskriver egenskaper hos system och till exempel material kan definieras med mekaniska, elektriska och kemiska parametrar. Fisherinformation är ett informationsmått som ger information om hur ändringar i en parameter påverkar estimeringen. Fisherinformationen ges av en fysikalisk modell av problemet och en statistisk modell av mätbruset. Cramér-Rao-gränsen är inversen av Fisherinformationen och ger den bästa möjliga variansen för alla väntevärdesriktiga estimatorer.Den här avhandlingen behandlar aspekter av känslighetsanalys i två tillämpade estimeringsproblem för materialparametrar. Känslighetsanalys med Fisherinformation och Cramér-Rao-gränsen används som ett redskap för utvärdering av möjligheten att mäta och för jämförelser av mätuppställningar, samt som ett kvantitativt mått på avvägningen mellan noggrannhet och upplösning för inversa bilder. Den första tillämpningen är estimering av fibervinkeln hos träd och stockar. Fibervinkeln är vinkeln mellan växtriktningen och riktningen hos träfibern och en stor fibervinkel är relaterad till problem med formstabilitet i färdiga brädor. Mikrovågsmätningar av fibervinkeln presenteras som en snabb och robust mätteknik. I avhandlingen beskrivs två- och tredimensionella elektromagnetiska modeller som utnyttjar anisotropin hos trä. Eftersom matematisk modellering minskar komplexiteten och beräkningstiden är det en viktig del i estimeringen. Enligt känslighetsanalys med Cramér-Rao-gränsen är estimering av fibervinkeln hos trä möjlig. Den andra tillämpningen är elektrisk impedanstomografi, där ledningsförmågan hos objekt bestäms genom mätningar på ytan. Elektrisk impedanstomografi har tillämpningar inom till exempel medicinska bilder, geologisk övervakning och trämätningar. Olika mätkonfigurationer och brusmodeller utvärderas med känslighetsanalys för ett tvådimensionellt exempel på elektrisk impedanstomografi. Relationen mellan noggrannhet och upplösning analyseras med Fisher information. För att sammanfatta beskrivs känslighetsanalys som en metod för att förbättra estimeringen av materialparametrar. Metoderna för känslighetsanalys är generella och kan tillämpas också på andra estimeringsproblem för parametrar.
82

Imagerie fonctionnelle de la ventilation et de l’inflammation pulmonaires lors d'agression pulmonaire aiguë expérimentale / Functional imaging of pulmonary ventilation and inflammation in an experimental model of lung injury

Pouzot-Névoret, Céline 09 November 2010 (has links)
Le syndrome de détresse respiratoire aiguë (SDRA) est caractérisé par des lésions alvéolairesdiffuses qui résultent d’une lésion de la membrane alvéolo-capillaire entrainant entre autresune réaction inflammatoire intense et une perte massive et hétérogène du volume pulmonaireaéré. La tomographie par émission de positons (TEP) et la tomographie par impédanceélectrique (TIE) sont deux techniques d’imagerie fonctionnelle permettant l’étude noninvasive, quantitative et régionale du poumon.Ce travail présente le résultat d’études expérimentales conduites dans le SDRA. Tout d’abord,nous avons comparé positivement la TIE à la TEP pour la mesure de la ventilation pulmonaireet du volume aéré. Nous avons ensuite décrit et validé une technique robuste d’obtention duvolume aéré et de la ventilation spécifique en TEP sans prélèvement invasif. Enfin, nousavons étudié en TEP l’influence de la pression expiratoire positive (PEP) et du décubitusventral (DV) sur la répartition de la ventilation, de la perfusion et de l’inflammationpulmonaires. Les poumons agressés par l’acide chlorhydrique inhalé ont une inflammationsignificativement plus élevée que le groupe contrôle. Aucune différence significatived’inflammation n’a été trouvée entre les groupes expérimentaux malgré des modificationsimportantes de la répartition de la ventilation et de la perfusion régionales lors de la mise enDV. Ces études donc ont permis le développement d’un modèle porcin stable d’agressionpulmonaire aiguë et la validation de techniques d’imagerie permettant l’étude non invasive deparamètres physiologiques importants pouvant aider au réglage de la ventilation mécanique aucours du SDRA. / Acute respiratory distress syndrome (ARDS) is characterized by diffuse alveolar damage andresulting from an increased permeability of the alveolar-capillary membrane. Of notice, thereis an intense lung inflammation. Positron emission tomography (PET) and electricalimpedance tomography (EIT) allow noninvasive assessment of pulmonary ventilation,perfusion and inflammation. We use these techniques to decipher the impairments ofventilation and inflammation throughout the lungs in an experimental model of acute lunginjury by hydrochloric acid inhalation in pigs.In a first study, we compared EIT to PET in quantifying pulmonary aerated volume andventilation, using PET as a gold standard. We found that lung ventilation and volume wereaccurately measured with EIT over a wide range of lung volume and minute ventilation. Wehave then described and validated a new model to obtain lung aerated volume and ventilationwith PET, without the requirement of gas sampling in the respiratory circuit. Finally, weconducted a controlled study with PET to evaluate the effects of positive end-expiratorypressure and body position on regional lung inflammation, ventilation and perfusion.Inflammation was significantly higher in injured groups than in control. However, there wasno significant change in inflammation across ALI groups despite significant differencebetween ventilation and perfusion repartition.We have developed in this work a stable experimental model of acute lung injury andvalidated noninvasive imaging tools allowing studying of important physiologic parametersthat could help setting up mechanical ventilation.
83

Estudo do aumento do desempenho de um sistema de tomografia de impedância elétrica através do método de otimização topológica. / Increasing electrial impedance tomography system performance through the topology optimization method.

Mello, Luís Augusto Motta 27 January 2010 (has links)
A Tomografia de Impedância Elétrica é uma técnica de obtenção de imagens do interior de um corpo, mediante grandezas elétricas medidas em sua superfície. Matematicamente, a técnica determina as distribuições de condutividades e permissividades elétricas num dado modelo do corpo, as quais reproduzem as medidas de correntes e potenciais elétricos em eletrodos fixados ao corpo. Nesse caso, as distribuições de condutividades e permissividades representam a solução de um problema não-linear e mal-posto, o qual é instável e apresenta mínimos locais, requerendo técnicas de inversão específicas. Um sistema de Tomografia de Impedância Elétrica aplicado à obtenção de imagens de valores absolutos possui, atualmente, limitações. São algumas delas a obtenção de distribuições de propriedades suaves e de valores geralmente subestimados, a sensibilidade elevada ao erro de posicionamento dos eletrodos (com relação ao modelo) e ao erro nos valores de parâmetros de contato, a sensibilidade elevada aos ruídos de medição, os tempos elevados de processamento, dentre outros. Com o intuito de abordar as limitações, melhorando o desempenho do sistema de Tomografia de Impedância Elétrica de imagens absolutas, são então propostas e avaliadas ferramentas baseadas no Método de Otimização Topológica no atual trabalho. Mais especificamente, avaliam-se: 1) um método para obtenção de parâmetros de contato em conjunto com uma imagem e um método de regularização baseado no controle explícito da variação espacial da imagem, 2) uma formulação para acomodação de incertezas, 3) uma formulação para correção do posicionamento de eletrodos, 4) uma formulação para projeto de eletrodos e 5) um novo solucionador de sistemas lineares de larga escala. Os resultados mostram a efetividade da maioria das técnicas propostas, e sugerem os novos tópicos de pesquisa em Tomografia de Impedância Elétrica. / Electrical Impedance Tomography images the interior of a body based on electrical quantities measured on the surface of it. Mathematically, the technique finds the electric admittivity distribution in a given body model which reproduces the boundary measurements of electric currents and potentials on electrodes attached to that body. Therefore, the admittivity distribution is the solution of a non-linear and ill-posed problem, which is unstable and have local minima, requiring specific inversion techniques. Electrical Impedance Tomography systems which obtain images corresponding to absolute values present limitations. For instance, the results are usually smooth and underestimated, the sensitivity to errors in the positioning of electrodes and wrong values of contact parameters and the sensitivity to measurement noise are high, the data processing time is high, etc. In this work, techniques based on the Topology Optimization Method intended for improving the performance of the particular Electrical Impedance Tomography system applied to absolute images are proposed and evaluated. More specifically, the following techniques are evaluated: 1) a method intended to obtain contact parameters together with images, and a regularization method based on the explicit control of the spatial variation regarding the image, 2) a formulation applied to handle uncertainties, 3) a formulation applied to correct the position of electrodes, 4) a formulation applied to design electrodes, 5) and a new solver for large-scale linear systems. Results show the effectiveness of most of the proposed techniques, and suggest new research topics in Electrical Impedance Tomography.
84

Titulação da PEEP rápida versus lenta guiadas por tomografia de impedância elétrica em pacientes hipoxêmicos no pós-operatório imediato de cirurgia cardíaca: estudo clínico randomizado / Fast versus slow PEEP trial guided by electrical impedance tomography in hypoxemic patients following cardiac surgery: randomized controlled trial

Nakamura, Maria Aparecida Miyuki 04 April 2018 (has links)
OBJETIVO: avaliar a concordância entre duas titulações decrementais de PEEP guiadas por tomografia de impedância elétrica (TIE): uma rápida, com tempo total inferior a 7 minutos, e uma lenta, com 40 minutos, e comparar os efeitos hemodinâmicos causados pelas duas titulações; e como objetivo secundário, comparar os efeitos fisiológicos da PEEP ótima escolhida pela TIE com a PEEP escolhida pela tabela PEEP-FiO2 do ARDSNet, durante 4 horas de ventilação mecânica. MÉTODOS: Trata-se de um estudo clínico, randomizado, unicêntrico que incluiu pacientes hipoxêmicos no pós-operatório imediato de cirurgia cardíaca. Os pacientes foram randomizados em 3 grupos: Titulação Rápida, Titulação Lenta ou Controle (tabela PEEP-FiO2 do ARDSNet). Os grupos Titulação Rápida e Titulação Lenta foram submetidos a duas titulações de PEEP guiadas pela TIE (uma rápida e uma lenta) precedidas de manobra de recrutamento alveolar. A titulação da PEEP foi realizada da PEEP de 23 cmH2O até a PEEP de 5 cmH2O, em passos decrementais de 2 cmH2O, com duas durações: 40 segundos na Titulação Rápida ( < 7 minutos no total), ou 4 minutos na Titulação Lenta (40 minutos no total). A PEEP ótima (PEEPTIT) foi definida como a menor PEEP com menos de 5% de colapso estimado pela TIE. No grupo Controle, a PEEP foi ajustada de acordo com a oxigenação, baseada no protocolo ARDSNet. Todos os pacientes permaneceram em ventilação mecânica por 4 horas com a PEEP de acordo com seu grupo, e foram monitorados com TIE durante todo estudo. A comparação entre as manobras de Titulação Rápida e Lenta incluiu as seguintes variáveis: colapso recrutável e hiperdistensão estimados pela TIE, valor da PEEPTIT, menor pressão arterial média e dose de noradrenalina durante as titulações. A comparação com o grupo controle incluiu: nível de PEEP, complacência do sistema respiratório, driving pressure, colapso e hiperdistensão estimados pela TIE (associação entre o ZMIN - que representa a aeração - e a Complacência Z avaliados regionalmente), e oxigenação (PaO2/FiO2) ao longo das 4 horas de acompanhamento. RESULTADOS: Não houve diferença entre colapso e hiperdistensão estimados pela Titulação Rápida e Lenta, nem nos valores de PEEPTIT (13 ± 4 vs 14 ± 4 cmH2O, P=0,13). A pressão arterial média foi maior durante a titulação rápida (92mmHg [IQ25-75%: 81-111] vs 83mmHg [71-93], P=0,035) e não houve diferença no uso de noradrenalina. A PEEPTIT pela TIE foi significativamente mais alta do que a PEEP do Grupo Controle. Os grupos Titulação Rápida e Lenta apresentaram comportamentos semelhantes após ajuste da PEEPTIT, e houve aumento significativo na complacência do sistema respiratório no primeiro minuto, que permaneceu maior que a condição basal ao final das 4 horas (T. Lenta: 0,73 ± 0,2 vs 0,89 ± 0,1 mL/cmH2O/Kg do peso predito, P < 0,001; T. Rápida: 0,7 ± 0,1 vs 0,85 ± 0,2 mL/cmH2O/Kg do peso predito, P < 0,001); com a melhora da complacência houve redução da driving pressure e, ao final das 4 horas, esta permaneceu menor que no tempo basal. No grupo controle, a complacência não mudou durante as 4 horas de ventilação mecânica (0,63 ± 0,1 vs 0,58 ± 0,1 mL/cmH2O/Kg do peso predito, P=0,34) e a driving pressure aumentou significativamente. A oxigenação melhorou nos três grupos, mas foi mais alta nos grupos PEEPTIT guiados pela TIE. Após ajuste da PEEPTIT, em ambos os grupos (Titulação Rápida e Lenta) houve aumento da aeração nas regiões dependente e não dependente, recrutamento na região dependente e não houve hiperdistensão na região não dependente, mesmo com a PEEP mais alta. No grupo controle, de acordo com a tabela PEEP-FiO2, a necessidade de PEEP diminuiu ao longo do tempo (6,1 ± 1,4 cmH2O no tempo 4 horas), causando redução da aeração. CONCLUSÕES: Houve concordância entre titulações rápida e lenta guiadas pela TIE em relação à PEEPTIT, estimativa de colapso e hiperdistensão para cada passo de PEEP; a titulação rápida da PEEP pôde ser realizada com menor repercussão hemodinâmica quando comparada com a titulação convencional lenta. A PEEP individualizada pela TIE melhorou a complacência, reduziu a driving pressure e melhorou a oxigenação, sem causar hiperdistensão quando comparada com protocolo ARDSNet. Descritores: respiração com pressão positiva; mecânica respiratória; impedância elétrica; tomografia; procedimentos cirúrgicos cardíacos; respiração artificial; insuficiência respiratória; tomografia de impedância elétrica / OBJECTIVE: to assess the agreement of \"optimum-PEEP\" values selected by two decremental PEEP trials guided by electrical impedance tomography (EIT): a Fast one lasting less than 7 minutes, and a Slow one lasting 40 minutes, and to compare the hemodynamic effects caused by these two trials; as secondary objectives, we aimed at comparing the physiological effects of the optimum-PEEP chosen by EIT (Fast or Slow) with those chosen by ARDSNet PEEP-FiO2 table during the subsequent 4 hours of mechanical ventilation. METHODS: in this single center, randomized controlled trial, hypoxemic patients immediately after cardiac surgery were randomized into three groups: Fast Titration (FAST-EIT), Slow Titration (SLOW-EIT) and Control (ARDSNet PEEP-FiO2 table). After recruiting maneuvers, and starting from a PEEP of 23 cmH2O, the FAST-EIT and SLOW-EIT groups were submitted to decremental PEEP trials, in steps of 2 cmH2O, until reaching 5 cmH2O, with two different durations: 40 seconds (the entire maneuver lasted < 7 minutes) or 4 minutes (entire maneuver lasted 40 minutes). The optimum-PEEP (PEEPTIT) was defined as the lowest PEEP with less than 5% of collapse estimated by EIT. In the control group, PEEP was adjusted according to oxygenation based on ARDSNet protocol. All patients were ventilated for 4 hours with PEEP according to their randomized groups, and all were monitored with EIT during the study. The comparison between Fast and Slow PEEP trials included: recruitable collapse and hyperdistension estimated by EIT, level of optimum PEEP, lowest mean arterial pressure and norepinephrine doses during the trials. The comparison with the control group included: level of PEEP, compliance and driving pressure, collapse (aeration) and hyperdistension estimated with EIT, and oxygenation (PaO2/FiO2) during 4 hours of mechanical ventilation. RESULTS: There was no difference between recruitable collapse and hyperdistension estimated by EIT between Fast and Slow maneuvers, as well as for the PEEPTIT (13 ± 4 vs 14 ± 4 cmH2O, P=0.13). Mean arterial pressure was higher during the Fast maneuver in comparison to the Slow maneuver (92mmHg [IQ25-75%: 81-111] vs 83mmHg [71-93], P=0.035), without differences in norepinephrine. FAST-EIT and SLOW-EIT groups presented similar changes during the time: after set PEEPTIT there was an immediate and significant improvement in respiratory-system compliance, which remained above baseline condition during the 4 hours of mechanical ventilation (SLOW-EIT: from 0.73 ± 0.2 to 0.89 ± 0.1 mL/cmH2O/Kg of PBW, P < 0.001; FAST-EIT: from 0.7 ± 0.1 to 0.85 ± 0.2 mL/cmH2O/Kg of PBW, P < 0.001); as respiratory compliance improved, driving pressure significantly reduced and remained lower than the baseline condition after 4 hours. In the control group, respiratory compliance did not change between baseline and 4 hours (from 0.63 ± 0.1 to 0.58 ± 0.1 mL/cmH2O/Kg of PBW, P=0.34) but driving pressure significantly increased as PEEP decreased. Oxygenation improved in all groups, but it was higher in the EIT groups. After setting PEEPTIT in both EIT groups (Fast or Slow), there was an increase in aeration in both, nondependent and dependent regions. In contrast, regional compliance increased in the dependent region and didn\'t change in nondependent region, suggesting that the strategy caused long-lasting recruitment of dependent regions and did not produced hyperdistension of non-dependent lung. In the control group, the required PEEP, adjusted by ARDSNet PEEP-FiO2 table, decreased along the time, causing evident collapse in EIT derived signals. CONCLUSION: There was no difference between recruitable collapse and hyperdistension estimated by EIT and PEEPTIT between Fast and Slow maneuvers; Fast PEEP trial guided by EIT could be performed in less than 7 minutes, with less hemodynamic consequences than the traditional Slow maneuver. Individualized PEEP guided by EIT improved respiratory compliance, reduced driving pressure and improved oxygenation without causing hyperdistension - when compared to a PEEP set according the ARDSNet protocol
85

Titulação da PEEP rápida versus lenta guiadas por tomografia de impedância elétrica em pacientes hipoxêmicos no pós-operatório imediato de cirurgia cardíaca: estudo clínico randomizado / Fast versus slow PEEP trial guided by electrical impedance tomography in hypoxemic patients following cardiac surgery: randomized controlled trial

Maria Aparecida Miyuki Nakamura 04 April 2018 (has links)
OBJETIVO: avaliar a concordância entre duas titulações decrementais de PEEP guiadas por tomografia de impedância elétrica (TIE): uma rápida, com tempo total inferior a 7 minutos, e uma lenta, com 40 minutos, e comparar os efeitos hemodinâmicos causados pelas duas titulações; e como objetivo secundário, comparar os efeitos fisiológicos da PEEP ótima escolhida pela TIE com a PEEP escolhida pela tabela PEEP-FiO2 do ARDSNet, durante 4 horas de ventilação mecânica. MÉTODOS: Trata-se de um estudo clínico, randomizado, unicêntrico que incluiu pacientes hipoxêmicos no pós-operatório imediato de cirurgia cardíaca. Os pacientes foram randomizados em 3 grupos: Titulação Rápida, Titulação Lenta ou Controle (tabela PEEP-FiO2 do ARDSNet). Os grupos Titulação Rápida e Titulação Lenta foram submetidos a duas titulações de PEEP guiadas pela TIE (uma rápida e uma lenta) precedidas de manobra de recrutamento alveolar. A titulação da PEEP foi realizada da PEEP de 23 cmH2O até a PEEP de 5 cmH2O, em passos decrementais de 2 cmH2O, com duas durações: 40 segundos na Titulação Rápida ( < 7 minutos no total), ou 4 minutos na Titulação Lenta (40 minutos no total). A PEEP ótima (PEEPTIT) foi definida como a menor PEEP com menos de 5% de colapso estimado pela TIE. No grupo Controle, a PEEP foi ajustada de acordo com a oxigenação, baseada no protocolo ARDSNet. Todos os pacientes permaneceram em ventilação mecânica por 4 horas com a PEEP de acordo com seu grupo, e foram monitorados com TIE durante todo estudo. A comparação entre as manobras de Titulação Rápida e Lenta incluiu as seguintes variáveis: colapso recrutável e hiperdistensão estimados pela TIE, valor da PEEPTIT, menor pressão arterial média e dose de noradrenalina durante as titulações. A comparação com o grupo controle incluiu: nível de PEEP, complacência do sistema respiratório, driving pressure, colapso e hiperdistensão estimados pela TIE (associação entre o ZMIN - que representa a aeração - e a Complacência Z avaliados regionalmente), e oxigenação (PaO2/FiO2) ao longo das 4 horas de acompanhamento. RESULTADOS: Não houve diferença entre colapso e hiperdistensão estimados pela Titulação Rápida e Lenta, nem nos valores de PEEPTIT (13 ± 4 vs 14 ± 4 cmH2O, P=0,13). A pressão arterial média foi maior durante a titulação rápida (92mmHg [IQ25-75%: 81-111] vs 83mmHg [71-93], P=0,035) e não houve diferença no uso de noradrenalina. A PEEPTIT pela TIE foi significativamente mais alta do que a PEEP do Grupo Controle. Os grupos Titulação Rápida e Lenta apresentaram comportamentos semelhantes após ajuste da PEEPTIT, e houve aumento significativo na complacência do sistema respiratório no primeiro minuto, que permaneceu maior que a condição basal ao final das 4 horas (T. Lenta: 0,73 ± 0,2 vs 0,89 ± 0,1 mL/cmH2O/Kg do peso predito, P < 0,001; T. Rápida: 0,7 ± 0,1 vs 0,85 ± 0,2 mL/cmH2O/Kg do peso predito, P < 0,001); com a melhora da complacência houve redução da driving pressure e, ao final das 4 horas, esta permaneceu menor que no tempo basal. No grupo controle, a complacência não mudou durante as 4 horas de ventilação mecânica (0,63 ± 0,1 vs 0,58 ± 0,1 mL/cmH2O/Kg do peso predito, P=0,34) e a driving pressure aumentou significativamente. A oxigenação melhorou nos três grupos, mas foi mais alta nos grupos PEEPTIT guiados pela TIE. Após ajuste da PEEPTIT, em ambos os grupos (Titulação Rápida e Lenta) houve aumento da aeração nas regiões dependente e não dependente, recrutamento na região dependente e não houve hiperdistensão na região não dependente, mesmo com a PEEP mais alta. No grupo controle, de acordo com a tabela PEEP-FiO2, a necessidade de PEEP diminuiu ao longo do tempo (6,1 ± 1,4 cmH2O no tempo 4 horas), causando redução da aeração. CONCLUSÕES: Houve concordância entre titulações rápida e lenta guiadas pela TIE em relação à PEEPTIT, estimativa de colapso e hiperdistensão para cada passo de PEEP; a titulação rápida da PEEP pôde ser realizada com menor repercussão hemodinâmica quando comparada com a titulação convencional lenta. A PEEP individualizada pela TIE melhorou a complacência, reduziu a driving pressure e melhorou a oxigenação, sem causar hiperdistensão quando comparada com protocolo ARDSNet. Descritores: respiração com pressão positiva; mecânica respiratória; impedância elétrica; tomografia; procedimentos cirúrgicos cardíacos; respiração artificial; insuficiência respiratória; tomografia de impedância elétrica / OBJECTIVE: to assess the agreement of \"optimum-PEEP\" values selected by two decremental PEEP trials guided by electrical impedance tomography (EIT): a Fast one lasting less than 7 minutes, and a Slow one lasting 40 minutes, and to compare the hemodynamic effects caused by these two trials; as secondary objectives, we aimed at comparing the physiological effects of the optimum-PEEP chosen by EIT (Fast or Slow) with those chosen by ARDSNet PEEP-FiO2 table during the subsequent 4 hours of mechanical ventilation. METHODS: in this single center, randomized controlled trial, hypoxemic patients immediately after cardiac surgery were randomized into three groups: Fast Titration (FAST-EIT), Slow Titration (SLOW-EIT) and Control (ARDSNet PEEP-FiO2 table). After recruiting maneuvers, and starting from a PEEP of 23 cmH2O, the FAST-EIT and SLOW-EIT groups were submitted to decremental PEEP trials, in steps of 2 cmH2O, until reaching 5 cmH2O, with two different durations: 40 seconds (the entire maneuver lasted < 7 minutes) or 4 minutes (entire maneuver lasted 40 minutes). The optimum-PEEP (PEEPTIT) was defined as the lowest PEEP with less than 5% of collapse estimated by EIT. In the control group, PEEP was adjusted according to oxygenation based on ARDSNet protocol. All patients were ventilated for 4 hours with PEEP according to their randomized groups, and all were monitored with EIT during the study. The comparison between Fast and Slow PEEP trials included: recruitable collapse and hyperdistension estimated by EIT, level of optimum PEEP, lowest mean arterial pressure and norepinephrine doses during the trials. The comparison with the control group included: level of PEEP, compliance and driving pressure, collapse (aeration) and hyperdistension estimated with EIT, and oxygenation (PaO2/FiO2) during 4 hours of mechanical ventilation. RESULTS: There was no difference between recruitable collapse and hyperdistension estimated by EIT between Fast and Slow maneuvers, as well as for the PEEPTIT (13 ± 4 vs 14 ± 4 cmH2O, P=0.13). Mean arterial pressure was higher during the Fast maneuver in comparison to the Slow maneuver (92mmHg [IQ25-75%: 81-111] vs 83mmHg [71-93], P=0.035), without differences in norepinephrine. FAST-EIT and SLOW-EIT groups presented similar changes during the time: after set PEEPTIT there was an immediate and significant improvement in respiratory-system compliance, which remained above baseline condition during the 4 hours of mechanical ventilation (SLOW-EIT: from 0.73 ± 0.2 to 0.89 ± 0.1 mL/cmH2O/Kg of PBW, P < 0.001; FAST-EIT: from 0.7 ± 0.1 to 0.85 ± 0.2 mL/cmH2O/Kg of PBW, P < 0.001); as respiratory compliance improved, driving pressure significantly reduced and remained lower than the baseline condition after 4 hours. In the control group, respiratory compliance did not change between baseline and 4 hours (from 0.63 ± 0.1 to 0.58 ± 0.1 mL/cmH2O/Kg of PBW, P=0.34) but driving pressure significantly increased as PEEP decreased. Oxygenation improved in all groups, but it was higher in the EIT groups. After setting PEEPTIT in both EIT groups (Fast or Slow), there was an increase in aeration in both, nondependent and dependent regions. In contrast, regional compliance increased in the dependent region and didn\'t change in nondependent region, suggesting that the strategy caused long-lasting recruitment of dependent regions and did not produced hyperdistension of non-dependent lung. In the control group, the required PEEP, adjusted by ARDSNet PEEP-FiO2 table, decreased along the time, causing evident collapse in EIT derived signals. CONCLUSION: There was no difference between recruitable collapse and hyperdistension estimated by EIT and PEEPTIT between Fast and Slow maneuvers; Fast PEEP trial guided by EIT could be performed in less than 7 minutes, with less hemodynamic consequences than the traditional Slow maneuver. Individualized PEEP guided by EIT improved respiratory compliance, reduced driving pressure and improved oxygenation without causing hyperdistension - when compared to a PEEP set according the ARDSNet protocol
86

Regionale Lungenventilation bei gesunden Probanden ermittelt mittels elektrischer Impedanztomographie / Distribution of ventilation in healthy individuals determined by electrical impedance tomography

Braun, Patrick 28 February 2011 (has links)
No description available.
87

Postoperatives Monitoring der regionalen Lungenventilation durch die Elektrische Impedanztomographie bei Kindern und Jugendlichen mit einem angeborenen Herzfehler / Postoperative monitoring of regional lungventilation using electrical impedance tomography in infants and adolescence with congenital heart desease

Becker, Kristin Eva 13 June 2012 (has links)
No description available.
88

Numerical study of an evolutionary algorithm for electrical impedance tomography / Numerische Untersuchung eines Evolutionären Algorithmus zur Elektrischen Impedanztomographie

Eckel, Harry 08 January 2008 (has links)
No description available.
89

Estudo do aumento do desempenho de um sistema de tomografia de impedância elétrica através do método de otimização topológica. / Increasing electrial impedance tomography system performance through the topology optimization method.

Luís Augusto Motta Mello 27 January 2010 (has links)
A Tomografia de Impedância Elétrica é uma técnica de obtenção de imagens do interior de um corpo, mediante grandezas elétricas medidas em sua superfície. Matematicamente, a técnica determina as distribuições de condutividades e permissividades elétricas num dado modelo do corpo, as quais reproduzem as medidas de correntes e potenciais elétricos em eletrodos fixados ao corpo. Nesse caso, as distribuições de condutividades e permissividades representam a solução de um problema não-linear e mal-posto, o qual é instável e apresenta mínimos locais, requerendo técnicas de inversão específicas. Um sistema de Tomografia de Impedância Elétrica aplicado à obtenção de imagens de valores absolutos possui, atualmente, limitações. São algumas delas a obtenção de distribuições de propriedades suaves e de valores geralmente subestimados, a sensibilidade elevada ao erro de posicionamento dos eletrodos (com relação ao modelo) e ao erro nos valores de parâmetros de contato, a sensibilidade elevada aos ruídos de medição, os tempos elevados de processamento, dentre outros. Com o intuito de abordar as limitações, melhorando o desempenho do sistema de Tomografia de Impedância Elétrica de imagens absolutas, são então propostas e avaliadas ferramentas baseadas no Método de Otimização Topológica no atual trabalho. Mais especificamente, avaliam-se: 1) um método para obtenção de parâmetros de contato em conjunto com uma imagem e um método de regularização baseado no controle explícito da variação espacial da imagem, 2) uma formulação para acomodação de incertezas, 3) uma formulação para correção do posicionamento de eletrodos, 4) uma formulação para projeto de eletrodos e 5) um novo solucionador de sistemas lineares de larga escala. Os resultados mostram a efetividade da maioria das técnicas propostas, e sugerem os novos tópicos de pesquisa em Tomografia de Impedância Elétrica. / Electrical Impedance Tomography images the interior of a body based on electrical quantities measured on the surface of it. Mathematically, the technique finds the electric admittivity distribution in a given body model which reproduces the boundary measurements of electric currents and potentials on electrodes attached to that body. Therefore, the admittivity distribution is the solution of a non-linear and ill-posed problem, which is unstable and have local minima, requiring specific inversion techniques. Electrical Impedance Tomography systems which obtain images corresponding to absolute values present limitations. For instance, the results are usually smooth and underestimated, the sensitivity to errors in the positioning of electrodes and wrong values of contact parameters and the sensitivity to measurement noise are high, the data processing time is high, etc. In this work, techniques based on the Topology Optimization Method intended for improving the performance of the particular Electrical Impedance Tomography system applied to absolute images are proposed and evaluated. More specifically, the following techniques are evaluated: 1) a method intended to obtain contact parameters together with images, and a regularization method based on the explicit control of the spatial variation regarding the image, 2) a formulation applied to handle uncertainties, 3) a formulation applied to correct the position of electrodes, 4) a formulation applied to design electrodes, 5) and a new solver for large-scale linear systems. Results show the effectiveness of most of the proposed techniques, and suggest new research topics in Electrical Impedance Tomography.
90

Estratégia para a solução numérica do problema inverso da identificação de inclusões em domínio condutor

Peters, Franciane Conceição 27 January 2010 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-02-23T19:26:50Z No. of bitstreams: 1 francianeconceicaopeters.pdf: 4730497 bytes, checksum: 201c60342a8bf9edc9b308fa50fafa54 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-02-24T12:08:43Z (GMT) No. of bitstreams: 1 francianeconceicaopeters.pdf: 4730497 bytes, checksum: 201c60342a8bf9edc9b308fa50fafa54 (MD5) / Made available in DSpace on 2017-02-24T12:08:43Z (GMT). No. of bitstreams: 1 francianeconceicaopeters.pdf: 4730497 bytes, checksum: 201c60342a8bf9edc9b308fa50fafa54 (MD5) Previous issue date: 2010-01-27 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A construção de imagens associadas à distribuição de condutividades no interior de um meio condutor a partir de injeção de corrente elétrica e medidas de potencial no contorno externo do corpo é uma técnica conhecida como tomografia por impedância elétrica. É um problema inverso que tem sido estudado visando aplicações biomédicas, monitoramento de processos industriais e investigação geofísica. Em alguns casos, é possível levar em consideração informações conhecidas sobre o domínio do corpo no processo de construção da imagem, recaindo no problema da detecção de inclusões que é o problema efetivamente tratado neste trabalho. Este problema pode ser resolvido por meio da minimização de uma função da diferença entre potenciais medidos no contorno e calculados para uma dada distribuição de condutividades. O presente trabalho desenvolve uma estratégia para a solução deste problema baseada na parametrização da geometria do contorno das inclusões cujas formas e dimensões se pretende determinar. O problema de minimização é resolvido por meio do Método de Levenberg-Marquardt e o problema direto via Método dos Elementos de Contorno. Para avaliar o desempenho da estratégia proposta são apresentados resultados numéricos envolvendo contornos definidos por splines, problemas com a presença de ruído nas medidas, avaliação de protocolos de injeção de corrente e medição de potencial elétrico e ainda uma aplicação voltada ao monitoramento cardíaco. / The images reconstruction of the conductivity distribution inside a conductive body based on electrical current injection and potential measurements on the outer boundary of this body is a technique known as electrical impedance tomography. This is an inverse problem that has been studied in biomedical applications, industrial process monitoring and geophysics investigation. In some cases, it is possible to take into account in the reconstruction process, informations about the body, leading to the problem of identifying inclusions, that is the problem actually treated in this work. This inverse problem can be solved by the minimization of a function, defined as the difference between the measured potentials and the computed ones for a given conductivity distribution. The present work describes a strategy to solve this problem based on the parametrization of the inclusions boundary, whose shape and size is intended to be determined. The minimization problem is solved via Levenberg-Marquardt Method and the forward one is solved via Boundary Elements Method. In order to evaluate the performance of the proposed strategy, numerical experiments with inclusions of boundaries defined by splines, problems with noisy data, current injection and potential measurement protocols and an application of the strategy to the cardiac function monitoring are presented.

Page generated in 0.2186 seconds