• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 26
  • Tagged with
  • 26
  • 26
  • 20
  • 15
  • 9
  • 9
  • 8
  • 8
  • 8
  • 7
  • 7
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Variação sazonal de episódios de taquicardia ventricular avaliados por Holter

Pimentel, Mauricio January 2004 (has links)
A variação sazonal de taquicardia ventricular (TV) e sua correlação com a temperatura foram avaliadas em 3.034 pacientes submetidos à realização de Holter em Porto Alegre, sul do Brasil. A distribuição dos pacientes por estações foi: verão 561 (18,5%), outono 756 (24,9%), inverno 843 (27,8%) e primavera 874 (28,8%). No verão, 52 pacientes apresentaram TV (9,3%), no outono, 39 (5,2%), no inverno, 56 (6,6%) e, na primavera, 60 (6,9%) (p = 0,035). Houve aumento relativo de 40% na proporção de pacientes com TV no verão em relação ao inverno. Houve tendência de aumento da proporção de pacientes com TV com o aumento da temperatura (r = 0,57; p = 0,052).
2

Avaliação da resposta eletrocardiográfica e sorológica ao tratamento com benzonidazol em pacientes na fase crônica da doença de Chagas / Electrocardiographic and serological evaluation to treatment with benznidazole in chronic Chagas disease patients

Andrade, Mônica Coelho January 2013 (has links)
ANDRADE, Mônica Coelho. Avaliação da resposta eletrocardiográfica e sorológica ao tratamento com benzonidazol em pacientes na fase crônica da Doença de Chagas. 2013. 91 f. Dissertação (Mestrado em Patologia) - Universidade Federal do Ceará. Faculdade de Medicina, Fortaleza, 2013. / Submitted by denise santos (denise.santos@ufc.br) on 2013-11-13T15:47:46Z No. of bitstreams: 1 2013_dis_mcandrade.pdf: 1300707 bytes, checksum: 95232e3c4673b4f51a96eb835ffb253e (MD5) / Approved for entry into archive by denise santos(denise.santos@ufc.br) on 2013-11-13T15:48:12Z (GMT) No. of bitstreams: 1 2013_dis_mcandrade.pdf: 1300707 bytes, checksum: 95232e3c4673b4f51a96eb835ffb253e (MD5) / Made available in DSpace on 2013-11-13T15:48:12Z (GMT). No. of bitstreams: 1 2013_dis_mcandrade.pdf: 1300707 bytes, checksum: 95232e3c4673b4f51a96eb835ffb253e (MD5) Previous issue date: 2013 / Chagas disease (CD) is a pathology of endemic nature, caused by the protozoan Trypanosoma cruzi, with pronounced relevance between heart disease. It was officially described in 1909 and even after more than a century of its discovery is still a public health problem. The aim of this study was to evaluate the effectiveness of chemotherapy with Benznidazole (Bz) in patients with chronic Chagas disease by serological analysis and electrocardiography. This is a prospective non-concurrent and concurrent study, where patients were followed serologically once a year after treatment, from 2005, 2006 or 2007 (before treatment) until 2011. The electrocardiographic evaluation was performed at baseline (2005-2007) and end of the study (2011). The patients were treated with Bz in dose of 5mg/kg/day in two to three daily doses for 60 days. The serological analysis was conducted, through the techniques of ELISA (enzyme immunoassay) and IIF (indirect immunofluorescence). The electrocardiographic evaluation was performed at the University Hospital Walter Cantídio through the electrocardiograms (ECG) available in patient charts. This study followed 31 patients, 20 (64,5%) male and 11 (35,5%) female, from 25 to 64 years, where 51.6% (16/31) did not finish high school and 22,6% (7/31) were farmers. Serological analysis by ELISA demonstrated a significant decrease in the optical density of the samples collected before (2005 to 2007) when compared with the samples after treatment (2011). Now with regard to IIF, patients remained unchanged during the segment (variation in a maximum of a dilution of the sample between baseline and 2011). Regarding the electrocardiographic evaluation, 76.2% (16/21) showed maintenance of electrocardiographic reports throughout the study, with the exception of cinco cases. One patient was excluded from analysis electrocardiographic (there wasn’t ECG performed in 2011) required a defibrillator implantation during follow-up (2010). In conclusion, one can say that although Bz presents limited effectiveness in patients in the chronic phase of CD, this study demonstrated a beneficial effect of the drug in most followed patients, as the majority of these reports showed maintenance of electrocardiographic and serology showed a downward trend. However, it is necessary a longer segment, since the follow-up period of this study (5-7 years) is considered short for patients in the chronic phase of the disease. / A doença de Chagas (DC) é uma patologia de natureza endêmica, causada pelo protozoário Trypanosoma cruzi, com pronunciada relevância entre as doenças cardíacas. Foi descrita oficialmente em 1909 e mesmo após mais de um século de sua descoberta ainda representa um problema de saúde pública. O objetivo deste trabalho foi avaliar a efetividade da quimioterapia com Benzonidazol (Bz) em pacientes chagásicos crônicos através de análise sorológica e eletrocardiográfica. Trata-se de um estudo prospectivo não concorrente e concorrente, onde os pacientes foram acompanhados sorologicamente uma vez ao ano depois do tratamento, a partir de 2005, 2006 ou 2007 (antes do tratamento) até 2011. A avaliação eletrocardiográfica foi realizada no início (2005 a 2007) e final da pesquisa (2011). Os pacientes foram tratados com Bz na dosagem de 5mg/Kg/dia em duas a três tomadas diárias durante 60 dias. A análise sorológica foi realizada através das técnicas de ELISA (Ensaio Imunoenzimático) e IFI (Imunofluorescência indireta). A avaliação eletrocardiográfica foi feita através dos eletrocardiogramas (ECG) realizados no Hospital Universitário Walter Cantídio e disponíveis nos prontuários dos pacientes. Foram acompanhados 31 pacientes, 20 (64,5%) do sexo masculino e 11 (35,5%) do feminino, de 25 a 64 anos, dos quais 51,6% (16/31) cursaram o primeiro grau incompleto e 22,6% (7/31) eram agricultores. A análise sorológica através do teste ELISA demonstrou queda significativa da densidade óptica das amostras coletadas antes (2005 a 2007) em relação às amostras pós-tratamento (2011). Com relação à IFI, os pacientes mantiveram-se inalterados durante o segmento (variação de no máximo uma diluição entre a amostra basal e 2011). No que diz respeito à avaliação eletrocardiográfica, 76,2% (16/21) apresentaram manutenção dos laudos eletrocardiográficos ao longo do estudo, com exceção de cinco casos. Um dos pacientes excluído da análise eletrocardiográfica (não existia ECG realizado em 2011) necessitou de um implante de desfibrilador ao longo do acompanhamento (2010). Em conclusão, pode-se afirmar que embora o Bz apresente efetividade limitada em pacientes na fase crônica da DC, este estudo demonstrou um efeito benéfico do medicamento na maioria dos pacientes acompanhados, já que a maioria destes apresentou manutenção dos laudos eletrocardiográficos e a sorologia mostrou uma tendência à queda. Entretanto, faz-se necessário um período maior de segmento, já que o tempo de acompanhamento deste estudo (5 a 7 anos) é considerado curto para pacientes na fase crônica da doença.
3

Variação sazonal de episódios de taquicardia ventricular avaliados por Holter

Pimentel, Mauricio January 2004 (has links)
A variação sazonal de taquicardia ventricular (TV) e sua correlação com a temperatura foram avaliadas em 3.034 pacientes submetidos à realização de Holter em Porto Alegre, sul do Brasil. A distribuição dos pacientes por estações foi: verão 561 (18,5%), outono 756 (24,9%), inverno 843 (27,8%) e primavera 874 (28,8%). No verão, 52 pacientes apresentaram TV (9,3%), no outono, 39 (5,2%), no inverno, 56 (6,6%) e, na primavera, 60 (6,9%) (p = 0,035). Houve aumento relativo de 40% na proporção de pacientes com TV no verão em relação ao inverno. Houve tendência de aumento da proporção de pacientes com TV com o aumento da temperatura (r = 0,57; p = 0,052).
4

Variação sazonal de episódios de taquicardia ventricular avaliados por Holter

Pimentel, Mauricio January 2004 (has links)
A variação sazonal de taquicardia ventricular (TV) e sua correlação com a temperatura foram avaliadas em 3.034 pacientes submetidos à realização de Holter em Porto Alegre, sul do Brasil. A distribuição dos pacientes por estações foi: verão 561 (18,5%), outono 756 (24,9%), inverno 843 (27,8%) e primavera 874 (28,8%). No verão, 52 pacientes apresentaram TV (9,3%), no outono, 39 (5,2%), no inverno, 56 (6,6%) e, na primavera, 60 (6,9%) (p = 0,035). Houve aumento relativo de 40% na proporção de pacientes com TV no verão em relação ao inverno. Houve tendência de aumento da proporção de pacientes com TV com o aumento da temperatura (r = 0,57; p = 0,052).
5

Fibrilação atrial crônica e apnéia obstrutiva do sono / Sleep-disordered breathing and chronic atrial fibrillation

Silva, Betania Braga [UNIFESP] 28 October 2009 (has links) (PDF)
Made available in DSpace on 2015-07-22T20:50:15Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-10-28. Added 1 bitstream(s) on 2015-08-11T03:25:31Z : No. of bitstreams: 1 Publico-00381.pdf: 1723817 bytes, checksum: 88648ea03390ba5c0d314c941c1e8ca5 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Associação Fundo de Incentivo à Psicofarmacologia (AFIP) / Introducao: Pouco se sabe sobre a relacao da apneia do sono com a fibrilacao atrial. Alguns estudos recentes sugerem que a prevalencia da fibrilacao atrial esta aumentada nos pacientes com disturbios respiratorios do sono, sendo possivel que a apneia do sono contribua para o surgimento da arritmogenese nestes. A hipotese deste trabalho foi observar se a prevalencia da apneia obstrutiva do sono era maior nos pacientes com fibrilacao atrial cronica, e se a presenca de tal arritmia estava relacionada a alteracoes no padrao de sono. Objetivos: Avaliar a prevalencia da apneia obstrutiva do sono, assim como os parametros da estrutura do sono, em um grupo de pacientes com fibrilacao atrial cronica, comparado com uma amostra da populacao geral. Metodos: Avaliaram-se 52 pacientes com o diagnostico de fibrilacao atrial cronica persistente ou permanente, com a idade media de 60,5 } 9,5 anos, sendo 33 destes homens. Uma amostra de 32 pacientes do estudo epidemiologico sobre os disturbios respiratorios do sono em uma populacao geral da cidade de Sao Paulo, Brasil (EPISONO) constituiu o grupo controle, com a idade media de 57,3 } 9,6 anos, sendo 15 deles homens. Todos os pacientes foram submetidos a uma avaliacao cardiologica e encaminhados para a realizacao de uma polissonografia completa. Resultados: Considerando o indice de apneia/hipopneia . 10 por hora de sono, o grupo com a fibrilacao atrial apresentou uma alta prevalencia de apneia obstrutiva do sono (respectivamente, 81,6% e 60,0%, p=0,03). Todos os parametros de saturacao de oxigenio foram piores no grupo com a fibrilacao atrial: saturacao de oxigenio minima (81,9 } 5,8% e 85,3 } 5,2%, p=0,01), saturacao de oxigenio media (93,4 } 2,1% e 94,3 } 1,5%, p=0,02) e porcentagem de tempo de saturacao menor do que 90% (26,4 } 55,8% e 6,7 } 12,3%, p=0,05). Nao houve diferencas em relacao a idade, ao genero, ao indice de massa corporal, ao sedentarismo, a presenca de hipertensao arterial, ao diabetes mellitus tipo 2, a circunferencia abdominal, a pressao arterial sistolica e diastolica e ao resultado da escala de sonolencia entre os grupos. A despeito do indice de massa corporal similar, os pacientes com a fibrilacao atrial apresentaram maior circunferencia cervical em relacao ao grupo controle (39,9 } 2,3 cm e 37,7 } 4,5, p=0,01) e uma maior porcentagem de tempo no estagio 1 do sono nao REM, sono superficial (6,4 } 5,9% e 3,9 } 2,6%, p=0,03). Conclusoes: Os disturbios respiratorios do sono foram mais prevalentes entre os pacientes com a fibrilacao atrial cronica em comparacao a populacao em geral. Os parametros da saturacao do oxigenio e a porcentagem do sono superficial foram piores no grupo com a fibrilacao atrial do que no grupo controle. Em conjunto, todas estas conclusoes sugeriram que nos pacientes avaliados, houve uma alteracao do acoplamento cardio-respiratorio durante o sono. / Background: Little has been known about the relation of sleep apnea and atrial fibrillation. Recent studies have suggested that the prevalence of atrial fibrillation is increasing in patients with sleep-disordered breathing and it is possible that the sleep apnea contributes to arrhythmogenesis in these patients.We hypothesize that the prevalence of obstructive sleep apnea is higher in chronic atrial fibrillation patients, and the arrhythmia occurrence may be associated to alterations in the sleep patterns. Objectives: To evaluate the prevalence of obstructive sleep apnea, and the sleep respiratory parameters in a sample of chronic atrial fibrillation compared to a sub-sample of the general population. Methods: Fifty-two chronic persistent and permanent atrial fibrillation patients, aged (60.5 } 9.5, 33 males) and 32 control subjects were taken from a sample of an epidemiological study on sleep disorders in the general population of the city of Sao Paulo, Brazil (EPISONO), mean aged 57.3 } 9.6 years old, 15 males. All subjects were evaluated by a staff cardiologist for the presence of medical conditions, and were referred for polysomnography. Results: Considering a cut-off value for apnea hypopnea index . 10 per hour of sleep, the atrial fibrillation group had a higher prevalence of obstructive sleep apnea compared to the control group (81.6% and 60.0%, respectively, p = 0.03). All the oxygen saturation parameters were significantly worse in the AF group, such as: lower oxygen saturation nadir (81.9 } 5.8% and 85.3 } 5.2%, p = 0.01), lower mean oxygen saturation (93.4 } 2.1% and 94.3 } 1.5%, p = 0.02), and longer period of time below 90% (26.4 } 55.8 min and 6.7 } 12.3 min, p = 0.05).There were no differences in age, gender, body mass index, sedentarism, presence of hypertension, type 2 diabetes mellitus, abdominal circumference, systolic and diastolic blood pressure, and sleepiness scoring between groups. Despite similar body mass index, atrial fibrillation patients had a higher neck circumference compared to control group (39.9 } 2.3 cm and 37.7 } 4.5 cm, p = 0.01) and the atrial fibrillation group showed higher percentage time of stage 1 non-REM sleep, superficial sleep (6.4 } 5.9% and 3.9 } 2.6%, p = 0.03). Conclusions: Sleep-disordered breathing is more prevalent in chronic atrial fibrillation patients than in general population subjects. The oxygen saturation parameters and percentage of time spent in superficial sleep were worse in the atrial fibrillation group than in control group. Overall, these data suggest alteration of the cardio respiratory coupling during sleep, in these patients. / FAPESP: 98/14303-3 / TEDE / BV UNIFESP: Teses e dissertações
6

Estudo retrospectivo e prospectivo da relação alométrica entre frequência cardíaca, parâmetros eletrocardiográficos e peso corporal em cães

Aleixo, Amanda Sarita Cruz. January 2016 (has links)
Orientador: Maria Lúcia Gomes Lourenço / Banca: Simone Biagio Chiacchio / Banca: Rodrigo Prevedello Franco / Resumo: A relação alométrica entre frequência cardíaca (FC) e peso corporal, postulada há anos, vem sendo refutada. Estudos acerca da variação e influência de fatores sobre parâmetros hemodinâmicos e eletrocardiográficos em cães não são abundantes. O escopo deste estudo foi avaliar a relação entre FC e peso corporal em cães, bem como a influência do peso sobre os parâmetros eletrocardiográficos (ECG). Foi realizado um estudo retrospectivo (1) mediante a análise da relação entre FC, parâmetros eletrocardiográficos e peso corporal através de traçados de ECG armazenados pelo Serviço de Cardiologiadurante os anos de 2012-2013;já no estudoprospectivo (2) - utilizou-se a eletrocardiografia e o exame de Holter para análise da variabilidade da frequência cardíaca e determinação das variáveis clínicas: peso corporal, idade, raça, sexo, temperamento, frequência respiratória (FR), temperatura corporal, pressão arterial sistêmica e dosagem séricade adrenalina e noradrenalina, dividindo-se os cães em cinco grupos de peso: < 5 kg (8), 5-10 (10), 10-25 (10), 25-45 (10) e > 45 kg (10). As variáveis do ECG variaram conforme o peso. A amplitude da onda R foi maior em cães com idade acima de cinco anos. A concentração de adrenalina aumentou conforme aumento do peso corporal. A FC foi maior no grupo de animais nervosos e a FR foi maior no grupo de animais agitados. As correlações obtidas entre FC e peso e FC e ASC foram fracas. Não houve diferença entre os índices do Holter entre os grupos de pesos.Não existe relação alométrica entre FC e peso corporal em cães. Existe uma relação diretamente proporcional entre adrenalina e peso em cães. O temperamento altera os parâmetros clínicos FC e FR. O peso influencia as variáveis eletrocardiográficas. A análise da FC deve ser realizada considerando-se patamares (direcionada ao metabolismo energético, segundo a faixa etária, sexo e temperamento). / Abstract: The allometric relationship between heart rate (HR) and body weight, posited for years, has been refuted. Studies on the variation and influence of several factors on the hemodynamic and electrocardiographic parameters in dogs are not plentiful. The scope of this study was to evaluate the relationship between HR and body weight in healthy dogs, as well as the influence of the weight on the electrocardiographic parameters (ECG). We conducted a retrospective study (1) by means of the analysis of the relationship between HR, electrocardiographic parameters and body weight in ECG tracings stored by cardiology department during the years 2012-2013; prospective study (2)analyzing the ambulatory electrocardiogram and by Holter method for analysis of heart rate variability and clinical variables measurement: body weight, age, breed, gender, temperament, breath rate (BR), body temperature and blood pressure, and dosage of serum catecholamines epinephrine and norepinephrine, into five groups of dogs divided according to different weight ranges: < 5 kg (8), 5-10 (10), 10-25 (10), 25-45 (10) e > 45 kg (10). The ECG variables varied according to weight. The amplitude of the R wave was higher in dogs above five years. The epinephrine concentration increased as body weight increased. HR was higher in the group of nervous animals and BR was higher in the group with agitated animals. The correlations between HR and weight and HR and body surface area were weak. There was no difference between the Holter indices among the weight groups. There is no allometric relationship between HR and body weight in dogs. There is a directly proportional relationship between epinephrine and weight in dogs. Temperament changes the clinical parameters HR and BR. The weight influences the electrocardiographic variables. The HR analysis should be performed considering levels (directed to energy metabolism, according to age, gender and temperament). / Mestre
7

Hipertrofia ventricular esquerda na hipertensão resistente = análise de aspectos eletrocardiográficos, vetorcardiográficos e ecocardiográficos / Left ventricular hypertrophy in resistant hypertension : analysis of electrocardiographic, vectorcardiographic and echocardiographic features

Ludovico, Nelson Dinamarco, 1971- 02 October 2012 (has links)
Orientador: Heitor Moreno Junior / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-20T00:15:25Z (GMT). No. of bitstreams: 1 Ludovico_NelsonDinamarco_D.pdf: 11127350 bytes, checksum: fac2a775e3c6969068fdbd9ca7d14542 (MD5) Previous issue date: 2012 / Resumo: A hipertrofia ventricular esquerda caracterizada como lesão de órgão alvo aumenta o risco de morbi-mortalidade de 5 a 9 vezes quando presente. A detecção precoce da HVE permite a identificação de pacientes com risco, além de permitir a intervenção de forma precoce, melhorando o planejamento estratégico para o seu manejo. A hipertensão arterial resistente é caracterizada pelo paciente, que mesmo em uso de três medicações em doses otimizadas, sendo um deles diurético, ainda se mantém fora das metas preconizadas. Vários métodos diagnósticos de hipertrofia estão disponíveis para o diagnóstico da HVE, entre eles se destaca o ecocardiograma com elevada sensibilidade, especificidade e acurácia, o eletrocardiograma, com elevada especificidade, porém baixa sensibilidade e acurácia, em contrapartida com excelente reprodutibilidade e baixo custo operacional, e fácil realização, inclusive em locais afastados dos grandes centros, em contraposição ao ecocardiograma. Outro método, não muito usado na prática clínica, o vetorcardiograma, pode atualmente, ser realizado no mesmo equipamento do eletrocardiograma, justificando assim a sua empregabilidade na prática clínica diária. Apresentou em nosso estudo a mesma baixa sensibilidade e acurácia que o eletrocardiograma, compatíveis com estudos publicados recentemente, porém a associação de dois critérios, um eletrocardiográfico e outro vetorcardiográfico melhorou a sensibilidade e acurácia na detecção da hipertrofia ventricular esquerda, sem prejuízo para a especificidade, com valores próximos ao ecocardiograma / Abstract: Left ventricular hypertrophy characterized as target-organ damage increases the risk of morbidity and mortality 5-9 times when present. Early detection of LVH allows the identification of patients at risk, and allows intervention at an early stage, improving strategic planning for its management. The resistant hypertension is characterized by the patient, even taking three medications in doses optimized, one being a diuretic, is still outside of the recommended goals. Several diagnostic methods are available to hypertrophy the diagnosis of LVH, including echocardiography stands out with high sensitivity, specificity and accuracy, the electrocardiogram, with high specificity but low sensitivity and accuracy, in contrast with excellent reproducibility and low operating cost, and easy to perform, even in places far from the large centers, in contrast echocardiography. Another method, not widely used in clinical practice, the vectorcardiogram, can now be performed on the same equipment on the electrocardiogram, thereby justifying their employability in daily clinical practice. In our study vectorcardiography presented the same low sensitivity and accuracy than electrocardiography, consistent with recently published studies, but the combination of two criteria, an electrocardiogram and other vetorcardiográfico improved sensitivity and accuracy in detecting left ventricular hypertrophy, without prejudice to the specificity, with values close to echocardiography / Doutorado / Farmacologia / Doutor em Farmacologia
8

Eventos arrítmicos em pacientes com canalopatias cardíacas submetidos à anestesia local odontológica: estudo piloto randomizado / Arrhythmic events in patients with cardiac channelopathies subjected to local dental anesthesia: a randomized pilot study

Oliveira, Ana Carolina Guimarães 14 May 2019 (has links)
Introdução: Distúrbios dos canais iônicos cardíacos potencialmente letais, como a síndrome de Brugada (SBr), a síndrome do QT longo congênito (SQTL) e a taquicardia ventricular polimórfica catecolaminérgica (TVPC) podem ser responsáveis por pelo menos um terço do total de casos de morte súbita que permanecem inexplicados. Estes pacientes, por vezes, não obtêm tratamento odontológico e analgesia adequados devido à falta de informações na literatura em relação à dose e tipo de anestésico local recomendado, e ao risco potencial de eventos cardíacos ameaçadores à vida e instabilidade hemodinâmica. Métodos: Trata-se de um estudo piloto, randomizado, duplo-cego e cruzado com portadores de canalopatias cardíacas submetidos a tratamento odontológico restaurador em duas sessões, realizadas com intervalo mínimo de sete dias (wash-out) entre ambas, sendo o paciente seu próprio controle. Na primeira sessão, por randomização, o paciente recebeu uma das soluções anestésicas: lidocaína 2% sem vasoconstritor (LSA) ou lidocaína 2% com adrenalina 1:100.000 (LCA), originando duas condições: sem adrenalina e com adrenalina; na segunda sessão recebeu o outro anestésico. Todos foram monitorados com Holter por 28 horas, contadas a partir de uma hora antes do procedimento, nas duas sessões do estudo. Durante o atendimento odontológico, foram feitos registros pontuais em três momentos por meio de eletrocardiograma de 12 derivações, esfigmomanômetro digital para pressão arterial e escala de mensuração da ansiedade. Resultados: Sessenta e dois procedimentos restauradores foram realizados em 31 pacientes: 16 (51,6%) tinham SQTL, 12 (38,7%) SBr e três (9,7%) TVPC, dentre os quais 12 (38,7%) eram portadores de cardiodesfibrilador implantável. A idade média dos pacientes foi 45,2+15,8 anos, sendo 21 (67,7%) do sexo feminino. Os valores médios da frequência cardíaca máxima se mostraram aumentados com o uso de LCA no período da anestesia (84,4 x 80,4 bpm; p=0,005) com diferença estatisticamente significante entre as duas condições, assim como o QTc em pacientes com SQTL (465,4 x 450,1; p=0,009). Valores de pressão arterial e mensuração da ansiedade não mostraram diferença estatisticamente significante. Não foram observadas arritmias ventriculares ameaçadoras à vida durante os procedimentos. Conclusões: O uso da anestesia local com lidocaína, independente do uso de vasoconstritor, não resultou em arritmias ameaçadoras à vida e foi considerado seguro nos pacientes selecionados. Estes resultados preliminares devem ser confirmados em uma população maior, em um estudo multicêntrico / Background: Ion channel disorders, such as Brugada syndrome (BS), long QT syndrome (LQTS), and catecholaminergic polymorphic ventricular tachycardia (CPVT), may account for at least one-third of unexplained sudden cardiac deaths. These patients often do not receive adequate dental treatment and analgesia owing to the lack of information in the literature regarding the dose and type of local anesthetic recommended, and due to the potential risk of life-threatening cardiac events. Methods: This is a randomized, double-blind pilot trial in patients with cardiac CCh underwent to restorative dental treatment in two sessions, with a wash-out period of 7 days (crossover trial). In the first session, by randomization, the patient received one of the anesthetic solutions: 2% lidocaine without vasoconstrictor (LSA) or 2% lidocaine with epinephrine 1: 100,000 (LCA), making two conditions: without epinephrine and with epinephrine; and in the second session received the other anesthetic. Twenty-eight-hour Holter monitoring was performed in all patients, initiated one hour before the procedure, in the two study sessions. During the dental treatment, additional specific monitoring including 12-lead electrocardiography (ECG), digital sphygmomanometry and anxiety scale assessments was also applied at three time points. Results: Sixty-two dental procedures were performed in 31 patients with CCh: 16 (51.6%) had LQTS, 12 (38.7%) had BS and three (9.7%) had CPVT; 12 (38.7%) patients had an implantable defibrillator. The mean age was 45.2+15.8 years, and 21 (67.7%) patients were female. The maximum heart rate was increased after the use of epinephrine during the anesthesia period (84,4 x 80,4 bpm, p=0.005), as well the corrected QT in LQTS patients (465,4 x 450,1; p=0,009). Blood pressure and anxiety measurements showed no statistically significant differences. No life-threatening arrhythmias occurred during the dental treatment. Conclusions: The use of local dental anesthesia with lidocaine, regardless of the use of a vasoconstrictor, did not result in life-threatening arrhythmias and was considered safe in these selected patients with channelopathies. These preliminary findings need to be confirmed in a larger population study, in a multicenter study
9

Avaliação dos eventos arrítmicos em candidatos a transplante renal pela monitorização cardíaca com looper implantável / Long-term recording of arrhythmic events with implantable cardiac monitor in renal transplant candidates

Silva, Rodrigo Tavares 22 August 2011 (has links)
INTRODUÇÃO: pacientes com doença renal crônica em diálise apresentam elevada mortalidade anual, principalmente decorrente de eventos cardiovasculares, com destaque para morte súbita cardíaca (MSC). Os eventos arrítmicos (EA) são considerados os principais responsáveis pela MSC, tornando relevante a sua avaliação. Dispositivos cardíacos modernos como o looper implantável, que tem capacidade de monitorar o ritmo cardíaco por longo período de tempo e diagnosticar EA, podem contribuir na estratificação de risco desta população. OBJETIVOS: avaliar a taxa de ocorrência dos EA em candidatos a transplante renal com looper implantável e identificar fatores associados; determinar a significância prognóstica dos EA na MSC e mortalidade total; avaliar eficiência diagnóstica do looper e o papel da diálise. MÉTODOS: estudo clínico observacional, prospectivo e aberto que incluiu cem candidatos a transplante renal, em hemodiálise e com alto risco para transplante (idade >=50 anos, DM ou doença cardiovascular). Entre junho/2009 e janeiro/2010, os pacientes foram submetidos ao implante do looper para detecção dos EA e seguimento clínico de um ano. A idade média do grupo foi 59 anos; 65% homens; 97% hipertensos, 70% diabéticos, 34% com infarto prévio e tempo médio de 53,8 meses em hemodiálise. O diagnóstico dos EA seguiu protocolo específico e foram descritos todos os eventos clínicos fatais e não fatais. A estatística incluiu: análise descritiva dos EA, associação destes com variáveis exploratórias pelos testes de qui-quadrado, exato de Fischer, t-Student, Mann-Whitney e regressão logística stepwise selection para análise multivariada (p<0,05). RESULTADOS: foram diagnosticados 5075 EA em 98 pacientes em seguimento médio de 425 dias. A taxa de ocorrência dos EA na casuística foi: bradiarritmias (25%), arritmias supraventriculares (94%) e arritmias ventriculares (79%). Os EA mais comuns foram: taquicardia sinusal (39%) e atrial não sustentada (27%), extrassístoles ventriculares e atriais isoladas (16% e 5,4%) e taquicardia ventricular não sustentada (TVNS - 5,3%). Foram preditores para ocorrência dos EA: duração intervalo PR (p=0,0008; OR=1,05; IC-95%=1,02-1,08) e QT longo (p=0,002; OR=7,28; IC- 95%=2,01-26,35) para bradiarritmias; duração intervalo QTc (p=0,022; OR=1,02; IC-95%=1,01-1,04) e presença de insuficiência cardíaca (p=0,034; OR=9,87; IC- 95%=1,17-82,79) para arritmias ventriculares e dilatação ventricular esquerda (p=0,041; OR=2,83; IC-95%=1,01-7,96) para TVNS. Ocorreram 35 eventos clínicos não fatais, 14 transplantes renais e 18 óbitos. Dentre os óbitos, 38,9% foram cardiovasculares súbitos: quatro arritmogênicos, um IAM e dois indeterminados. Não houve associação entre EA e eventos fatais; fibrilação atrial e bradiarritmias tiveram associação significativa com eventos não fatais. O mecanismo de morte (arritmogênico) foi elucidado pelo looper em quatro pacientes com MSC; um paciente apresentou bloqueio atrioventricular e necessitou de marca-passo. A taxa de EA foi superior no período intradiálise em comparação ao interdiálise (p<0,001). CONCLUSÕES: neste estudo, que avaliou a monitorização cardíaca prolongada com looper implantável em candidatos a transplante renal, a taxa de ocorrência de EA foi elevada; foram preditores dos EA: a duração intervalo PR e presença de QT longo para bradiarritmias, duração intervalo QTc e insuficiência cardíaca para arritmias ventriculares e dilatação ventricular para TVNS; a taxa de mortalidade foi elevada, com importante contribuição da MSC; não houve associação entre EA e mortalidade total ou súbita; houve associação entre as bradiarritmias e a fibrilação atrial com a ocorrência de eventos não fatais; os EA foram mais frequentes no período intradiálise; o looper implantável foi eficiente na elucidação diagnóstica, com poucas complicações. / INTRODUCTION: chronic kidney disease patients undergoing dialysis have a high annual mortality rate, mainly due to cardiovascular disease. Sudden cardiac death (SCD), attributed to arrhythmic mechanisms, is considered the major cause of these high death rates. The implantable loop recorder (ILR), a modern cardiac device has the ability for long-term cardiac rhythm monitoring and diagnosing arrhythmic events (AE), which in fact may contribute to the risk stratification of this population. OBJECTIVES: this study was designed to evaluate the incidence and predictors of AE in renal transplant candidates with ILR; to determine the prognostic significance of AE in SCD and all-cause mortality, evaluate the diagnostic effectiveness of ILR and the role of dialysis. METHODS: a prospective, open, observational clinical study was conducted, including one hundred renal transplant candidates undergoing hemodialysis, at high risk for transplantation (age >=50 years, diabetes or cardiovascular disease). Between June/2009 and January/2010, patients received an ILR for detection of AE with a one-year follow-up. Mean age of the group was 59 years; 65% were men; 97% hypertensive, 70% diabetic, 34% had previous myocardial infarction and mean hemodialysis time was 53.8 months. The diagnosis of AE followed specific protocol and all fatal and non-fatal clinical events were described. The statistical analysis included: descriptive analysis of AE, an association between these events and exploratory variables by chi-square tests, Fisher exact test, Student\'s t test, Mann-Whitney test and logistic regression using stepwise selection for multivariate analysis (p<0.05). RESULTS: during mean follow-up of 425 days, 5075 AE were diagnosed by ILR in 98 patients. The rate of occurrence of EA in this patients was: bradyarrhythmias (25%), supraventricular arrhythmias (94%) and ventricular arrhythmias (79%). The most common AE were: sinus tachycardia (39%), nonsustained atrial tachycardia (27%), isolated premature ventricular beats (16%), isolated premature atrial beats (5.4%) and nonsustained ventricular tachycardia (NSVT - 5.3%). Predictors for the occurrence of AE were: duration of PR interval (p=0.0008; OR=1.05; 95%CI=1.02-1.08) and long QT (p=0.002; OR=7.28; 95%CI=2.01-26.35) for bradyarrhythmia; duration of QTc interval (p=0.022; OR=1.02; 95%CI=1.01-1.04) and presence of heart failure (p=0.034; OR=9.87; 95%CI=1.17-82.79) for ventricular arrhythmia and left ventricular dilatation (p=0.041; OR=2.83; 95%CI=1.01-7.96) for NSVT. There were 35 non-fatal clinical events, 14 renal transplantations and 18 deaths during follow-up. Regarding causes of death, 38.9% were due to sudden cardiovascular event: four were arrhythmogenic, one resulted from acute myocardial infarction and two were indeterminate. There was no association between AE and all cause or sudden mortality; bradyarrhythmias and atrial fibrillation were associated with the occurrence of non-fatal clinical events. The mechanism of death (arrhythmogenic) was elucidated by ILR in four patients with SCD; one patient had atrioventricular block and required pacemaker insertion. The rate of AE was higher in the intradyalitic period compared to interdialytic (p <0.001). CONCLUSIONS: in this study, which evaluate long-term cardiac rhythm monitoring with ILR in renal transplant candidates, the incidence of AE was high; predictors for the occurrence of AE were: duration of PR interval and presence of long QT for bradyarrhythmia, duration of QTc interval and heart failure for ventricular arrhythmia and left ventricular dilatation for NSVT; mortality rate was high and SCD made an important contribution. There was no association between AE and all-cause mortality and SCD; bradyarrhythmias and atrial fibrillation were associated with non-fatal events; the EA rate was higher at intradialytic period; the ILR was efficient in elucidating diagnoses and had few complications.
10

Importância do eletrocardiograma de repouso, de alta resolução e do Holter de 24 horas em pacientes com miocárdio não compacto: relação com os achados do ecocardiograma e ressonância magnética cardíaca / Importance of resting electrocardiogram, high resolution and 24-hour Holter in patients with myocardial noncompaction: relation with echocardiogram findings, and cardiac magnetic resonance

Corrêa, Renata dos Santos 17 August 2018 (has links)
INTRODUÇÃO: A miocardiopatia não compactada (MNC) é caracterizada pela formação de trabéculas miocárdicas proeminentes com recessos intertrabeculares profundos no ventrículo esquerdo (VE). Os pacientes podem apresentar insuficiência cardíaca, tromboembolismo e/ou arritmia. Os avanços de métodos diagnósticos têm permitido um maior reconhecimento desta doença. Assim, o objetivo deste estudo foi analisar os achados do eletrocardiograma (ECG), Holter de 24hs e eletrocardiograma de alta resolução (ECGAR), e sua relação com ecocardiograma (ECO) transtorácico e pela ressonância magnética cardíaca (RMC) em pacientes com MNC. MÉTODOS: Foram analisados pacientes com diagnóstico de MNC pelo ECO e/ou RMC, em acompanhamento ambulatorial em nossa instituição. Esses pacientes foram submetidos à avaliação clínica, ECG de 12 derivações, Holter de 24hs e ECGAR. Os dados do ECG foram analisados por dois observadores e comparados com o grupo controle, saudáveis. RESULTADOS: Sessenta e seis pacientes com MNC (45,1 ± 17,3 anos, 56,1% do sexo masculino), e vinte controles (52,6 ± 19,2 anos, 30,0% do sexo masculino), foram incluídos neste estudo. Os pacientes apresentaram fração de ejeção do VE pelo ECO de 41,2 ± 9,4%, e pela RMC de 40,8 ± 16,9%. Os achados eletrocardiográficos mais frequentes foram alteração da repolarização ventricular (65,2%), sobrecarga do VE (24,2%) e extrassístoles ventriculares (EEVV) (19,7%); com índice de concordância interobservadores alto, entre todas as variáveis (p < 0,001), exceto sobrecarga biventricular. O grupo com fração de ejeção reduzida apresentou um maior número de casos com sobrecarga de átrio esquerdo e maior duração do QRS em relação ao grupo sem disfunção (p= 0,020; p=0,008, respectivamente). O grupo que apresentou realce tardio tem maior número de pacientes com bloqueio de ramo esquerdo/bloqueio divisional anterossuperior esquerdo e maior duração do QRS quando comparado ao grupo sem realce (p= 0,034; p=0,035, respectivamente). No Holter de 24 horas, 4,4% apresentou ritmo de fibrilação atrial e 18,2% taquicardia ventricular não sustentada (TVNS) relacionada com os diâmetros de átrio e ventrículos esquerdos pelo ECO (P=0,008, P=0,0048, respectivamente); houve correlação entre o aumento do volume diastólico final pela RMC e intervalo PR (r=0,414; p=0,007), EEVV (r=0,426; p < 0,005) e intervalo QRS (r=0,564; p < 0,001). Além disso, o realce tardio apresentou relação com TVNS (p=0,009), extrassístole atrial (p=0,002), EEVV (p=0,004), duração do QRS (p=0,002), pela análise do Holter de 24hs. O ECGAR estava alterado em 10,6% dos pacientes, sendo que destes 12,2% apresentavam disfunção ventricular. Houve correlação entre dilatação de cavidades esquerdas pelo ECO, com duração do QRS filtrado e Standard (STD) (r=0,577; p < 0,001), e relação entre QRS filtrado e realce tardio (p <0,001) e dilatação ventricular pela RMC com QRS filtrado e STD (p < 0,001 para ambos). Os pacientes que foram a óbito, no período de seguimento de 4 anos, tinham uma frequência maior de TVNS (p=0,006). CONCLUSÃO: Os pacientes com MNC apresentaram alterações significativas do ECG, ECGAR e Holter de 24hs, mais evidentes no grupo de pacientes com disfunção ventricular e realce tardio. Dessa forma, estes pacientes devem ser acompanhados mais frequentemente, pelo risco maior de desfecho clínico desfavorável ambulatory. / INTRODUCTION: Noncompacted cardiomyopathy (NCC) is characterized by the formation of prominent myocardial trabeculae with deep intertrabecular recesses in the left ventricle (LV). Patients may present with heart failure, thromboembolism and/or arrhythmia. Advances in diagnostic methods have allowed greater recognition of this disease. Thus, the aim of this study was to analyze the findings of electrocardiogram (ECG), 24-hour Holter and high resolution electrocardiogram (ECGAR), and its relationship with transthoracic echocardiogram (ECHO) and cardiac magnetic resonance imaging (MRI) in patients with MNC. METHODS: Patients with a diagnosis of NCC by ECGO and / or CMR were analyzed in an outpatient clinic at our institution. These patients underwent clinical evaluation, 12-lead ECG, 24-hour Holter, and ECGAR. ECG data were analyzed by two observers and compared to the healthy control group. RESULTS: Sixty-six patients with MNC (45.1 ± 17.3 years, 56.1% males), and twenty controls (52.6 ± 19.2 years, 30.0% males) were included in this study. The patients presented LV ejection fraction by ECHO of 41.2 ± 9.4%, and CMR of 40.8 ± 16.9%. The most frequent electrocardiographic findings were alteration of ventricular repolarization (65.2%), LV overload (24.2%) and ventricular extrasystoles (VEE) (19.7%); with a high interobserver agreement index among all variables (p < 0.001), except for biventricular overload. The group with reduced ejection fraction presented a higher number of cases with left atrial overload and longer duration of QRS compared to the group without dysfunction (p = 0.020, p = 0.008, respectively). The group that presented delayed enhancement had a higher number of patients with left bundle branch block / anterosuperior left divisional block and longer duration of the QRS when compared to the group without enhancement (p = 0.034, p = 0.035, respectively). In the 24-hour Holter, 4.4% presented atrial fibrillation and 18.2% non-sustained ventricular tachycardia (NSVT). This was related to left ventricular atrial and ventricular diameters (P = 0.008, P = 0.0048, respectively); (r = 0.414, p = 0.007), EEVV (r = 0.426, p < 0.005), and QRS interval (r = 0.564, p < 0.001) were correlated with the increase in final diastolic volume. In addition, the late enhancement was related to NSVT (p = 0.009), atrial extrasystole (p = 0.002), VLT (p = 0.004), QRS duration (p = 0.002), and 24h Holter analysis. The ECGAR was altered in 10.6% of the patients, of whom 12.2% had ventricular dysfunction. There was a correlation between left ventricular ECO dilatation with filtered QRS duration and standard (STD) (r = 0.577, p < 0.001), and the relationship between filtered QRS and late enhancement (p < 0.001) and ventricular dilation by MRI with filtered QRS and STD (p < 0.001 for both). Patients who died at the 4-year follow-up period had a higher frequency of NSVT (p = 0.006). CONCLUSION: Patients with NCC present significant ECG, ECGAR and Holter 24hs changes, most evident in the group of patients with ventricular dysfunction and late enhancement. Therefore, these patients should be monitored more frequently, due to the greater risk of unfavorable clinical outcome

Page generated in 0.4744 seconds