Spelling suggestions: "subject:"embolia pulmonary."" "subject:"embolias pulmonary.""
41 |
Trombose venosa profunda e tromboembolismo pulmonar no pós-operatório de cirurgia de revascularização miocárdica: pesquisa diagnóstica independente de suspeita clínica / Deep vein thrombosis and pulmonary embolism in the postoperative coronary artery bypass grafting: diagnosis investigation regardless of clinical suspicionVitor Ramos Borges Viana 19 November 2015 (has links)
Introdução: O termo tromboembolismo venoso (TEV) engloba trombose venosa profunda (TVP) e/ou tromboembolismo pulmonar (TEP). TEV tem sido considerado incomum após cirurgia de revascularização miocárdica (CRM), e Diretrizes recomendam profilaxia mecânica para todos os pacientes e acrescentar profilaxia com heparina apenas se o tempo de internação hospitalar for prolongado por complicações não hemorrágicas (Grau 2C). Objetivo: Pesquisar o diagnóstico de TEV no pós-operatório de CRM, independente de suspeita clínica, e analisar se os resultados podem contribuir para melhor definição das características clínicas de TEV após CRM. Métodos: Em estudo observacional, prospectivo, unicêntrico, 100 pacientes com doença arterial coronariana crônica realizaram tomografia computadorizada da artéria pulmonar (multidetectores-64) e ultrassonografia compressiva dos membros inferiores após CRM eletiva. Pacientes com alto risco para TEV foram excluídos. Resultados: Por livre escolha dos cirurgiões, 83 cirurgias foram realizadas com circulação extracorpórea e 17 sem extracorpórea. Em média, tomografia e ultrassonografia foram realizadas 7 ± 3 dias após a cirurgia. TEP isolada foi observada em 13/100 (13%), TEP e TVP simultâneos em 8/100 (8%), e TVP isolada em 4/100 (4%) pacientes, totalizando 25/100 (25%) TEVs. Entre as 21 TEPs, 3/21 (14%) envolveram artérias subsegmentares, 15/21 (71%) artérias segmentares, 1/21 (5%) artéria lobar e 2/21 (10%) artérias pulmonares centrais (tronco da artéria pulmonar e/ou seus ramos principais). Das 12 TVPs, todas foram distais (abaixo da veia poplítea) e 2/12 (17%) foram também proximais; 5/12 (42%) foram unilaterais, das quais 3/5 (60%) acometeram a perna contralateral à safenectomia. Nenhum TEV causou instabilidade hemodinâmica e nenhum deles foi clinicamente suspeitado. Conclusões: TEV é frequente e subdiagnosticado após CRM, talvez porque a maioria tenha localização distal e porque os procedimentos habituais desta cirurgia dificultam a suspeita diagnóstica. Os resultados enfatizam a recomendação de recentes Diretrizes que sugerem profilaxia mecânica para todos os pacientes, e ressaltam a necessidade de estudos randomizados para avaliar a relação de benefícios e os riscos de profilaxia farmacológica / Background: Venous thromboembolism (VTE) includes deep vein thrombosis (DVT) and/or pulmonary embolism (PE). Currently, VTE has been considered uncommon after coronary artery bypass grafting (CABG) and Guidelines suggest mechanical prophylaxis and adding prophylactic heparin if hospital course is prolonged by nonhemorrhagic complications (Grade2C). Objective: To search VTE after CABG, independent of clinical suspicion, and to analyze whether the results can aid in better defining the clinical characteristics of VTE after CABG. Methods: In a prospective, observational, single-center study, 100 patients with coronary artery disease underwent computed tomographic pulmonary angiography (multidetector-64) and lower-extremity venous compressive ultrasound after elective CABG. Patients at high risk for VTE were excluded. Results: At the discretion of surgeons, 83 surgeries were on-pump and 17 off-pump. On average, tomography and ultrasound were performed 7 ± 3 days after CABG. Isolated PE was observed in 13/100 (13%) patients, simultaneous PE and DVT in 8/100 (8%), and isolated DVT in 4/100 (4%), totaling 25/100 (25%) VTEs. Of the PEs 3/21 (14%) involved subsegmental, 15/21 (71%) segmental, 1/21 (5%) lobar and 2/21 (10%) central pulmonary arteries. Of the 12 DVTs all were distal (below the popliteal vein) and 2/12 (17%) were also proximal; 5/12 (42%) were unilateral, of which 3/5 (60%) on the contralateral vein saphenous harvested leg. No VTE caused hemodynamic instability and none was clinically suspected. Conclusions: VTE is frequent and underdiagnosed perhaps because the majority is distally localized and because the ordinary procedures of GABG conceal the diagnostic suspicion. The results emphasize the current guidelines\' recommendation suggesting mechanical prophylaxis for all patients and highlight the necessity of randomized studies to assess the risk/benefit ratio of pharmacological prophylaxis
|
42 |
Parâmetros quantitativos obtidos por tomografia computadorizada de dupla-energia na avaliação da perfusão pulmonar em modelo experimental de embolia e lesão pulmonar / Quantitative parameters obtained from dual-energy computed tomography in the evaluation of pulmonary perfusion in an experimental model of embolism and alveolar damageKay, Fernando Uliana 10 August 2018 (has links)
Nesta tese, buscou-se avaliar se a tomografia computadorizada de duplaenergia pós-contraste (TCDE) é capaz de detectar diferenças regionais da perfusão pulmonar em um modelo animal suíno incluindo variações de decúbito, lesão alveolar e oclusão da artéria pulmonar com balão, comparando estes resultados com os obtidos pela perfusão de primeira passagem com a tomografia computadorizada dinâmica (TCD). Dez suínos landrace foram divididos em Grupos A (N = 5, controle) e B (N = 5). Animais do Grupo B foram submetidos ao protocolo de lesão alveolar induzida por ventilação mecânica (LPIV). O volume sanguíneo perfundido e o fluxo sanguíneo pulmonar foram, respectivamente, estimados pela TCDE (%VSPTCDE) e pela TCD (FSPTCD), em diversas condições experimentais: posição supina versus prona, presença versus ausência de LPIV, presença ou ausência de oclusão da artéria pulmonar. A correlação entre %VSPTCDE e FSPTCD foi moderada (R = 0,60) com ampla variabilidade (intervalo 0,35-0,91) entre animais. %VSPTCDE e FSPTCD demonstraram padrões similares de heterogeneidade da perfusão pulmonar nas diferentes condições experimentais. Entretanto, reduções do %VSPTCDE causadas pela oclusão com balão foram em média -29,32 %, enquanto reduções do FSPTCD foram em média -86,78 % (p < 0,001). Estimativas quantitativas do VSPTCDE tiveram um erro médio de +4.3 ml/100g em comparação com o FSPTCD, com limites de concordância de 95 % entre -16,6 ml/100g e 25,1 ml/100g. A TCDE póscontraste é capaz de prover estimativas semiquantitativas que refletem a heterogeneidade regional da perfusão pulmonar causada por mudanças de decúbito, lesão alveolar e oclusão da artéria pulmonar com balão, apresentando moderada correlação com a perfusão de primeira passagem pela TCD / We aimed to evaluate whether contrast-enhanced dual-energy CT (DECT) detects regional pulmonary perfusion changes in a swine model of acute lung injury, with variations in decubitus and transient occlusion of the pulmonary artery, comparing these results with those obtained with dynamic CT perfusion (DynCT). Ten landrace swine were assigned to Groups A (N = 5, control) and B (N = 5). Group B was subjected to ventilator-induced lung injury (VILI). Perfused blood volume and pulmonary blood flow were quantified by DECT (PBVDECT) and DynCT (PBFDynCT), respectively, under different settings: supine versus prone, and with/without balloon occlusion of a pulmonary artery (PA) branch. Correlation of regional PBVDECT versus PBFDynCT was moderate (R = 0.60) with high variability (range 0.35-0.91) among the animals. Regional pulmonary perfusion changes assessed by %PBVDECT agreed with PBFDynCT in response to decubitus changes, lung injury and balloon occlusion in the multivariate analysis. However, reductions in %PBVDECT caused by balloon occlusion were in average -29.32 %, whereas reductions in PBFDynCT were in average -86.78 % (p < 0.001). Quantitative estimates of PBVDECT had a mean bias of +4.3 ml/100g in comparison with PBVDynCT, with 95 % confidence intervals between -16.6 ml/100g and 25.1 ml/100g. Semiquantitative contrastenhanced DECT reflects regional changes in perfusion caused decubitus changes, acute lung injury, and balloon occlusion of the PA, with moderate correlation in comparison with DynCT
|
43 |
Avaliação do impacto de mudanças técnicas introduzidas na operação de tromboendarterectomia pulmonar ao longo de 10 anos: estudo retrospectivo no InCor-HCFMUSP / Evaluation of the impact of technical changes introduced in the operation of pulmonary thromboendarterectomy over 10 years: retrospective study in InCor-HCFMUSPScudeller, Paula Gobi 03 May 2018 (has links)
INTRODUÇÃO: A hipertensão pulmonar tromboembólica crônica (HPTEC) é uma doença vascular pulmonar progressiva, cuja incidência varia de 0,56% a 3,2% em indivíduos com embolia pulmonar aguda (EPA) recorrente. Apesar do avanço nas opções de tratamento para HPTEC, a tromboendarterectomia pulmonar (TEAP) continua sendo padrão ouro, levando a melhora hemodinâmica e aumento da sobrevida. OBJETIVOS: Avaliar o impacto que mudanças técnicas intraoperatórias implementadas tiveram na evolução dos pacientes submetidos à TEAP em relação à morbimortalidade imediata e tardia, e também sobre o desenvolvimento do ato operatório. MÉTODOS: Estudo retrospectivo em portadores de HPTEC, submetidos à TEAP, no período de janeiro/2007 a maio/2016, divididos em 3 grupos, de acordo com intervenções implementadas. A 1ª intervenção consistiu em mudanças na circulação extracorpórea (CEC) e no tempo de parada circulatória total (PCT), e a 2ª intervenção incluiu alterações na CEC, técnicas anestésica e cirúrgica. A avaliação dos dados incluiu análise univariada para associações entre intervenções com variáveis de morbimortalidade e técnica operatória. O modelo de regressão multivariado foi aplicado para validar se as melhorias resultaram das intervenções implementadas. A análise de sobrevida foi feita por Kaplan-Meier. RESULTADOS: Foram avaliados 102 indivíduos, 62,8% mulheres, idade média de 49,1±14,8 anos, 65,7% estavam em classe funcional III-IV (NYHA). A avaliação hemodinâmica demonstrou hipertensão pulmonar importante, com valores médios elevados de pressão média na artéria pulmonar (PmAP; G1=52,9±14,45mmHg; G2=53,2±12,4mmHg; G3=53,3±12,5mmHg, p=0,992) e resistência vascular pulmonar (RVP; G1=828,4±295,13 dynas.s.cm-5; G2=838,9±428,4 dynas.s.cm-5; G3=969±417,3 dynas.s.cm-5, p=0,313). Os pacientes submetidos à TEAP mostraram aumento do tempo total de CEC entre os grupos (G1=192,3±39,4min; G2=251,7±33,4min; G3=298,2±40,2min, p < 0,001), como resultado da padronização dos tempos de esfriamento (G1=47,9±18,5min; G2=66,9±5,9min; G3=70,6±3,7min, p < 0,001), aquecimento (G1=66,8±17,7min; G2=87,2±8,1min; G3=107,7±23,5min, p < 0,001) e reperfusão (G1=25,5±7,6min; G2=20,7±8,4 min; G3=18,6±9,4min, p=0,007). A diminuição do número de operações com mais de 2 PCT (G1= 89%; G2= 60%; G3: 55%, p=0,002) foi decorrente do aumento da duração média de cada PCT (G1=15,5±2,9min; G2=17,8±1,7min; G3=19,2±2,0min, p < 0,001). Complicações pós-operatórias foram observadas em 88,5% dos pacientes, havendo redução significativa das complicações cirúrgicas (p=0,035), infecciosas (p=0,017) e neurológicas com sintomas permanentes (p=0,048) na comparação entre os 3 grupos. No seguimento após a alta, 85% estavam em classe funcional I-II (NYHA), sem melhora hemodinâmica significativa entre os grupos. Após a análise multivariada, o G3 apresentou 4,7 menos chances de complicação cirúrgica que G1 (p=0,034) e tempo de aquecimento menor que 83 minutos aumentou 4 vezes a chance de complicação infecciosa (p=0,002). A redução da mortalidade hospitalar e da sobrevida não foi significativa entre os grupos. CONCLUSÕES: Em relação à morbimortalidade imediata e tardia, o impacto das intervenções foi evidenciado pela redução das complicações neurológicas com sintomas permanentes, complicações cirúrgicas e infecciosas. Em relação ao ato operatório, o impacto foi evidenciado pelo aumento dos tempos totais de CEC, de esfriamento, de aquecimento, tempo médio das PCT, redução nos números de PCT e no tempo total de reperfusão / INTRODUCTION: Chronic thromboembolic pulmonary hypertension (CTEPH) is a progressive pulmonary vascular disease which incidence varies from 0.56% to 3.2% in individuals with recurrent acute pulmonary embolism (APE). Despite advances in treatment options for CTEPH, pulmonary endarterectomy (PE) remains a gold standard, leading to hemodynamic improvement and increased survival. OBJECTIVES: Evaluate the impact of intraoperative technical changes on the evolution of patients submitted to PE related to immediate and late morbimortality, as well as on the development of the operative procedure. METHODS: Retrospective study of patients with CTEPH, submitted to PE, between January 2007 and May 2016, divided into 3 groups, according to the implemented interventions. The first intervention consisted of changes in cardiopulmonary bypass (CPB) and total circulatory arrest time (CAT), and the second intervention included changes in CPB, anaesthetic and surgical techniques. The data analysis included a univariate analysis for associations between interventions with morbidity variables and operative technique. The multivariate regression model was applied to validate whether the improvements resulted from the interventions implemented. Survival analysis was performed using Kaplan-Meier. RESULTS: We evaluated 102 individuals, 62.8% were women, mean age was 49.1 ± 14.8 years, and 65.7% were in functional class III-IV (NYHA). The hemodynamic evaluation showed significant pulmonary hypertension, with mean values of mean pulmonary artery pressure (mPAP, G1 = 52.9 ± 14.45 mmHg, G2 = 53.2 ± 12.4 mmHg, G3 = 53.3 ± 12.5 mmHg, p = 0.992) and pulmonary vascular resistance (PVR, G1 = 828.4 ± 295.13 dynas.s.cm-5, G2 = 838.9 ± 428.4 dynas.s.cm-5, G3 = 969 ± 417.3 dynas.s.cm-5, p = 0.313). The patients submitted to PE showed an increase in the total CPB time between the groups (G1 = 192.3 ± 39.4min, G2 = 251.7 ± 33.4min, G3 = 298.2 ± 40.2min, p < 0.001), as a result of the standardization of cooling times (G1 = 47.9 ± 18.5min, G2 = 66.9 ± 5.9min, G3 = 70.6 ± 3.7min, p < 0.001), heating (G1 = 66.8 ± 17.7min, G2 = 87.2 ± 8.1min, G3 = 107.7 ± 23.5min, p < 0.001) and reperfusion (G1 = 25.5 ± 7.6min, G2 = 20.7 ± 8.4 min, G3 = 18.6 ± 9.4min, p = 0.007). The decrease in the number of operations with more than 2 CAT (G1 = 89%, G2 = 60%, G3: 55%, p = 0.002) was due to the increase in the average duration of each CAT (G1 = 15.5 ± 2, 9min, G2 = 17.8 ± 1.7min, G3 = 19.2 ± 2.0min, p < 0.001). Postoperative complications were observed in 88.5% of the patients, with a significant reduction in surgical (p = 0.035), infectious (p = 0.017) and neurological complications with permanent symptoms (p = 0.048) in the comparison between the three groups. In the post-discharge follow-up, 85% were in functional class I-II (NYHA), with no significant hemodynamic improvement between groups. After the multivariate analysis, G3 presented 4.7 less chance of surgical complication than G1 (p = 0.034) and warming time less than 83 minutes increased 4 times the chance of infectious complication (p = 0.002). The reduction in hospital mortality and survival was not significant between the groups. CONCLUSIONS: Regarding immediate and late morbimortality, the impact of interventions was evidenced by the reduction of neurological complications with permanent symptoms, surgical and infectious complications. Regarding the operative event, the impact was evidenced by the increase in total CPB, cooling, heating, mean CAT time, CAT reduction and total reperfusion time
|
44 |
Valor do teste de dosagem do Dímero - D plasmático no diagnóstico do tromboembolismo venoso agudo / Value of measure plasmatic D Dimer test to diagnosis of the acute thrombolism venousPiano, Luciana Pereira de Almeida de 29 October 2007 (has links)
Introdução: A doença tromboembólica é um distúrbio complexo multicausal com sinais e sintomas inespecíficos, confundindo-se com outras enfermidades. Devido à sua gravidade buscam-se estratégias objetivando obter um diagnóstico precoce. O teste de dosagem do dímero - D plasmático parece ser uma alternativa para exclusão do diagnóstico de tromboembolismo venoso agudo. Objetivo: Avaliar o valor do teste de dosagem de dímero - D plasmático, utilizando o método Enzyme Linked Fluorescent Assay (ELFA), na rotina diagnóstica de tromboembolismo venoso agudo. Métodos: Em 89 pacientes com sinais e sintomas sugestivos de tromboembolismo pulmonar e/ou trombose venosa profunda foram realizadas dosagens do dímero - D pela técnica ELFA no equipamento VIDAS® - BioMérieux. Foram calculados os valores da sensibilidade, especificidade, valores preditivos positivo e negativo e acurácia do teste, bem como a curva ROC da amostra estudada. Todos os pacientes foram submetidos a exame por imagem para confirmação do evento tromboembólico agudo. Foi calculado o índice kappa para analisar o resultado do teste dímero - D versus resultados de exames por imagem. Resultados: Entre os 89 pacientes estudados (média de idade 54,3 anos; 51 mulheres), 36 (40,4%) apresentaram TEV e 53 não apresentaram trombose aguda (59,6%). Entre os pacientes sem trombose aguda 15 (28,3%) apresentaram resultado de dímero - D negativo. Todos pacientes com trombose apresentaram resultado de dímero - D positivo. O teste apresentou sensibilidade de 100%; especificidade de 28,3%; valor preditivo positivo de 48,6%; valor preditivo negativo de 100% e exatidão de 57,3%. A ASC para a amostra total estudada foi igual a 0,734, indicando que o teste é um bom preditor de trombose aguda. O valor do índice kappa para a amostra total foi igual a 0,24 (p<0,001), indicando uma concordância fraca entre dímero - D e diagnóstico confirmatório de trombose. Conclusão: A dosagem do dímero - D pelo método ELFA foi capaz de excluir o diagnóstico de tromboembolismo venoso agudo nessa amostra estudada. Os resultados obtidos nessa amostra estudada permitiram concluir que o uso do teste dímero - D em pacientes com suspeita de tromboembolismo venoso revelou alta sensibilidade no diagnóstico dessa enfermidade. / Introduction: The thromboembolic disease is a multicausal complex disturb with signals and symptoms that confusing itself with other diseases. Because its gravity strategies search objecting to get a faster diagnosis. The measure plasmatic D dimer test seems to be an alternative for exclusion of the diagnostic of acute venous thromboembolism. Objectives: To evaluate the value of the measure plasmatic D dimer test, using the method Enzyme Linked Fluorescent Assay (ELFA), in the diagnostic of acute venous thromboembolism. Methods: In 89 patients with signals and symptoms suggestive of pulmonary thromboembolism and/or deep vein thrombosis had been carried through measure D dimer by technique ELFA equipment VIDAS® - BioMérieux. The values of sensibility, accuracy specificity, predictive values positive and negative and of the test had been calculated, as well as curve ROC of the sample studied. All the patients had been submitted the image exams for the confirmation of the acute thromboembolism event. It was calculated kappa ratio to compare D dimer test results with image exams results. Results: Between 89 studied patients (mean of age 54.3 years; 51 women), 36 (40.4%) they had presented and 53 had not presented acute thrombosis (59.6%). It enters the patients without acute thromboembolism 15 (28.3%) had presented resulted negative of D dimer. All patients with thrombosis had presented resulted positive of D dimer. The test presented 100% sensibility; 28.3% of specificity; positive predictive value was 48.6%; 100% of negative predictive value and accuracy value was 57.3%. The area under the curve (AUC) to total sample studied was 0.734, it was showed that the test have a good prediction to acute thrombosis. The kappa ratio value was 0.24 (p<0.001) showing a bad concordat n to thrombosis diagnostic. Conclusion: The measure of D dimer by method ELFA was able to exclude the diagnostic of acute venous thromboembolism in this sample studied. The results obtained in this sample studied let to conclude that the D dimer test in patients with suspected of acute thromboembolism presented high sensibility to diagnostic of this disease.
|
45 |
Parâmetros quantitativos obtidos por tomografia computadorizada de dupla-energia na avaliação da perfusão pulmonar em modelo experimental de embolia e lesão pulmonar / Quantitative parameters obtained from dual-energy computed tomography in the evaluation of pulmonary perfusion in an experimental model of embolism and alveolar damageFernando Uliana Kay 10 August 2018 (has links)
Nesta tese, buscou-se avaliar se a tomografia computadorizada de duplaenergia pós-contraste (TCDE) é capaz de detectar diferenças regionais da perfusão pulmonar em um modelo animal suíno incluindo variações de decúbito, lesão alveolar e oclusão da artéria pulmonar com balão, comparando estes resultados com os obtidos pela perfusão de primeira passagem com a tomografia computadorizada dinâmica (TCD). Dez suínos landrace foram divididos em Grupos A (N = 5, controle) e B (N = 5). Animais do Grupo B foram submetidos ao protocolo de lesão alveolar induzida por ventilação mecânica (LPIV). O volume sanguíneo perfundido e o fluxo sanguíneo pulmonar foram, respectivamente, estimados pela TCDE (%VSPTCDE) e pela TCD (FSPTCD), em diversas condições experimentais: posição supina versus prona, presença versus ausência de LPIV, presença ou ausência de oclusão da artéria pulmonar. A correlação entre %VSPTCDE e FSPTCD foi moderada (R = 0,60) com ampla variabilidade (intervalo 0,35-0,91) entre animais. %VSPTCDE e FSPTCD demonstraram padrões similares de heterogeneidade da perfusão pulmonar nas diferentes condições experimentais. Entretanto, reduções do %VSPTCDE causadas pela oclusão com balão foram em média -29,32 %, enquanto reduções do FSPTCD foram em média -86,78 % (p < 0,001). Estimativas quantitativas do VSPTCDE tiveram um erro médio de +4.3 ml/100g em comparação com o FSPTCD, com limites de concordância de 95 % entre -16,6 ml/100g e 25,1 ml/100g. A TCDE póscontraste é capaz de prover estimativas semiquantitativas que refletem a heterogeneidade regional da perfusão pulmonar causada por mudanças de decúbito, lesão alveolar e oclusão da artéria pulmonar com balão, apresentando moderada correlação com a perfusão de primeira passagem pela TCD / We aimed to evaluate whether contrast-enhanced dual-energy CT (DECT) detects regional pulmonary perfusion changes in a swine model of acute lung injury, with variations in decubitus and transient occlusion of the pulmonary artery, comparing these results with those obtained with dynamic CT perfusion (DynCT). Ten landrace swine were assigned to Groups A (N = 5, control) and B (N = 5). Group B was subjected to ventilator-induced lung injury (VILI). Perfused blood volume and pulmonary blood flow were quantified by DECT (PBVDECT) and DynCT (PBFDynCT), respectively, under different settings: supine versus prone, and with/without balloon occlusion of a pulmonary artery (PA) branch. Correlation of regional PBVDECT versus PBFDynCT was moderate (R = 0.60) with high variability (range 0.35-0.91) among the animals. Regional pulmonary perfusion changes assessed by %PBVDECT agreed with PBFDynCT in response to decubitus changes, lung injury and balloon occlusion in the multivariate analysis. However, reductions in %PBVDECT caused by balloon occlusion were in average -29.32 %, whereas reductions in PBFDynCT were in average -86.78 % (p < 0.001). Quantitative estimates of PBVDECT had a mean bias of +4.3 ml/100g in comparison with PBVDynCT, with 95 % confidence intervals between -16.6 ml/100g and 25.1 ml/100g. Semiquantitative contrastenhanced DECT reflects regional changes in perfusion caused decubitus changes, acute lung injury, and balloon occlusion of the PA, with moderate correlation in comparison with DynCT
|
46 |
Avaliação do impacto de mudanças técnicas introduzidas na operação de tromboendarterectomia pulmonar ao longo de 10 anos: estudo retrospectivo no InCor-HCFMUSP / Evaluation of the impact of technical changes introduced in the operation of pulmonary thromboendarterectomy over 10 years: retrospective study in InCor-HCFMUSPPaula Gobi Scudeller 03 May 2018 (has links)
INTRODUÇÃO: A hipertensão pulmonar tromboembólica crônica (HPTEC) é uma doença vascular pulmonar progressiva, cuja incidência varia de 0,56% a 3,2% em indivíduos com embolia pulmonar aguda (EPA) recorrente. Apesar do avanço nas opções de tratamento para HPTEC, a tromboendarterectomia pulmonar (TEAP) continua sendo padrão ouro, levando a melhora hemodinâmica e aumento da sobrevida. OBJETIVOS: Avaliar o impacto que mudanças técnicas intraoperatórias implementadas tiveram na evolução dos pacientes submetidos à TEAP em relação à morbimortalidade imediata e tardia, e também sobre o desenvolvimento do ato operatório. MÉTODOS: Estudo retrospectivo em portadores de HPTEC, submetidos à TEAP, no período de janeiro/2007 a maio/2016, divididos em 3 grupos, de acordo com intervenções implementadas. A 1ª intervenção consistiu em mudanças na circulação extracorpórea (CEC) e no tempo de parada circulatória total (PCT), e a 2ª intervenção incluiu alterações na CEC, técnicas anestésica e cirúrgica. A avaliação dos dados incluiu análise univariada para associações entre intervenções com variáveis de morbimortalidade e técnica operatória. O modelo de regressão multivariado foi aplicado para validar se as melhorias resultaram das intervenções implementadas. A análise de sobrevida foi feita por Kaplan-Meier. RESULTADOS: Foram avaliados 102 indivíduos, 62,8% mulheres, idade média de 49,1±14,8 anos, 65,7% estavam em classe funcional III-IV (NYHA). A avaliação hemodinâmica demonstrou hipertensão pulmonar importante, com valores médios elevados de pressão média na artéria pulmonar (PmAP; G1=52,9±14,45mmHg; G2=53,2±12,4mmHg; G3=53,3±12,5mmHg, p=0,992) e resistência vascular pulmonar (RVP; G1=828,4±295,13 dynas.s.cm-5; G2=838,9±428,4 dynas.s.cm-5; G3=969±417,3 dynas.s.cm-5, p=0,313). Os pacientes submetidos à TEAP mostraram aumento do tempo total de CEC entre os grupos (G1=192,3±39,4min; G2=251,7±33,4min; G3=298,2±40,2min, p < 0,001), como resultado da padronização dos tempos de esfriamento (G1=47,9±18,5min; G2=66,9±5,9min; G3=70,6±3,7min, p < 0,001), aquecimento (G1=66,8±17,7min; G2=87,2±8,1min; G3=107,7±23,5min, p < 0,001) e reperfusão (G1=25,5±7,6min; G2=20,7±8,4 min; G3=18,6±9,4min, p=0,007). A diminuição do número de operações com mais de 2 PCT (G1= 89%; G2= 60%; G3: 55%, p=0,002) foi decorrente do aumento da duração média de cada PCT (G1=15,5±2,9min; G2=17,8±1,7min; G3=19,2±2,0min, p < 0,001). Complicações pós-operatórias foram observadas em 88,5% dos pacientes, havendo redução significativa das complicações cirúrgicas (p=0,035), infecciosas (p=0,017) e neurológicas com sintomas permanentes (p=0,048) na comparação entre os 3 grupos. No seguimento após a alta, 85% estavam em classe funcional I-II (NYHA), sem melhora hemodinâmica significativa entre os grupos. Após a análise multivariada, o G3 apresentou 4,7 menos chances de complicação cirúrgica que G1 (p=0,034) e tempo de aquecimento menor que 83 minutos aumentou 4 vezes a chance de complicação infecciosa (p=0,002). A redução da mortalidade hospitalar e da sobrevida não foi significativa entre os grupos. CONCLUSÕES: Em relação à morbimortalidade imediata e tardia, o impacto das intervenções foi evidenciado pela redução das complicações neurológicas com sintomas permanentes, complicações cirúrgicas e infecciosas. Em relação ao ato operatório, o impacto foi evidenciado pelo aumento dos tempos totais de CEC, de esfriamento, de aquecimento, tempo médio das PCT, redução nos números de PCT e no tempo total de reperfusão / INTRODUCTION: Chronic thromboembolic pulmonary hypertension (CTEPH) is a progressive pulmonary vascular disease which incidence varies from 0.56% to 3.2% in individuals with recurrent acute pulmonary embolism (APE). Despite advances in treatment options for CTEPH, pulmonary endarterectomy (PE) remains a gold standard, leading to hemodynamic improvement and increased survival. OBJECTIVES: Evaluate the impact of intraoperative technical changes on the evolution of patients submitted to PE related to immediate and late morbimortality, as well as on the development of the operative procedure. METHODS: Retrospective study of patients with CTEPH, submitted to PE, between January 2007 and May 2016, divided into 3 groups, according to the implemented interventions. The first intervention consisted of changes in cardiopulmonary bypass (CPB) and total circulatory arrest time (CAT), and the second intervention included changes in CPB, anaesthetic and surgical techniques. The data analysis included a univariate analysis for associations between interventions with morbidity variables and operative technique. The multivariate regression model was applied to validate whether the improvements resulted from the interventions implemented. Survival analysis was performed using Kaplan-Meier. RESULTS: We evaluated 102 individuals, 62.8% were women, mean age was 49.1 ± 14.8 years, and 65.7% were in functional class III-IV (NYHA). The hemodynamic evaluation showed significant pulmonary hypertension, with mean values of mean pulmonary artery pressure (mPAP, G1 = 52.9 ± 14.45 mmHg, G2 = 53.2 ± 12.4 mmHg, G3 = 53.3 ± 12.5 mmHg, p = 0.992) and pulmonary vascular resistance (PVR, G1 = 828.4 ± 295.13 dynas.s.cm-5, G2 = 838.9 ± 428.4 dynas.s.cm-5, G3 = 969 ± 417.3 dynas.s.cm-5, p = 0.313). The patients submitted to PE showed an increase in the total CPB time between the groups (G1 = 192.3 ± 39.4min, G2 = 251.7 ± 33.4min, G3 = 298.2 ± 40.2min, p < 0.001), as a result of the standardization of cooling times (G1 = 47.9 ± 18.5min, G2 = 66.9 ± 5.9min, G3 = 70.6 ± 3.7min, p < 0.001), heating (G1 = 66.8 ± 17.7min, G2 = 87.2 ± 8.1min, G3 = 107.7 ± 23.5min, p < 0.001) and reperfusion (G1 = 25.5 ± 7.6min, G2 = 20.7 ± 8.4 min, G3 = 18.6 ± 9.4min, p = 0.007). The decrease in the number of operations with more than 2 CAT (G1 = 89%, G2 = 60%, G3: 55%, p = 0.002) was due to the increase in the average duration of each CAT (G1 = 15.5 ± 2, 9min, G2 = 17.8 ± 1.7min, G3 = 19.2 ± 2.0min, p < 0.001). Postoperative complications were observed in 88.5% of the patients, with a significant reduction in surgical (p = 0.035), infectious (p = 0.017) and neurological complications with permanent symptoms (p = 0.048) in the comparison between the three groups. In the post-discharge follow-up, 85% were in functional class I-II (NYHA), with no significant hemodynamic improvement between groups. After the multivariate analysis, G3 presented 4.7 less chance of surgical complication than G1 (p = 0.034) and warming time less than 83 minutes increased 4 times the chance of infectious complication (p = 0.002). The reduction in hospital mortality and survival was not significant between the groups. CONCLUSIONS: Regarding immediate and late morbimortality, the impact of interventions was evidenced by the reduction of neurological complications with permanent symptoms, surgical and infectious complications. Regarding the operative event, the impact was evidenced by the increase in total CPB, cooling, heating, mean CAT time, CAT reduction and total reperfusion time
|
47 |
Valor do teste de dosagem do Dímero - D plasmático no diagnóstico do tromboembolismo venoso agudo / Value of measure plasmatic D Dimer test to diagnosis of the acute thrombolism venousLuciana Pereira de Almeida de Piano 29 October 2007 (has links)
Introdução: A doença tromboembólica é um distúrbio complexo multicausal com sinais e sintomas inespecíficos, confundindo-se com outras enfermidades. Devido à sua gravidade buscam-se estratégias objetivando obter um diagnóstico precoce. O teste de dosagem do dímero - D plasmático parece ser uma alternativa para exclusão do diagnóstico de tromboembolismo venoso agudo. Objetivo: Avaliar o valor do teste de dosagem de dímero - D plasmático, utilizando o método Enzyme Linked Fluorescent Assay (ELFA), na rotina diagnóstica de tromboembolismo venoso agudo. Métodos: Em 89 pacientes com sinais e sintomas sugestivos de tromboembolismo pulmonar e/ou trombose venosa profunda foram realizadas dosagens do dímero - D pela técnica ELFA no equipamento VIDAS® - BioMérieux. Foram calculados os valores da sensibilidade, especificidade, valores preditivos positivo e negativo e acurácia do teste, bem como a curva ROC da amostra estudada. Todos os pacientes foram submetidos a exame por imagem para confirmação do evento tromboembólico agudo. Foi calculado o índice kappa para analisar o resultado do teste dímero - D versus resultados de exames por imagem. Resultados: Entre os 89 pacientes estudados (média de idade 54,3 anos; 51 mulheres), 36 (40,4%) apresentaram TEV e 53 não apresentaram trombose aguda (59,6%). Entre os pacientes sem trombose aguda 15 (28,3%) apresentaram resultado de dímero - D negativo. Todos pacientes com trombose apresentaram resultado de dímero - D positivo. O teste apresentou sensibilidade de 100%; especificidade de 28,3%; valor preditivo positivo de 48,6%; valor preditivo negativo de 100% e exatidão de 57,3%. A ASC para a amostra total estudada foi igual a 0,734, indicando que o teste é um bom preditor de trombose aguda. O valor do índice kappa para a amostra total foi igual a 0,24 (p<0,001), indicando uma concordância fraca entre dímero - D e diagnóstico confirmatório de trombose. Conclusão: A dosagem do dímero - D pelo método ELFA foi capaz de excluir o diagnóstico de tromboembolismo venoso agudo nessa amostra estudada. Os resultados obtidos nessa amostra estudada permitiram concluir que o uso do teste dímero - D em pacientes com suspeita de tromboembolismo venoso revelou alta sensibilidade no diagnóstico dessa enfermidade. / Introduction: The thromboembolic disease is a multicausal complex disturb with signals and symptoms that confusing itself with other diseases. Because its gravity strategies search objecting to get a faster diagnosis. The measure plasmatic D dimer test seems to be an alternative for exclusion of the diagnostic of acute venous thromboembolism. Objectives: To evaluate the value of the measure plasmatic D dimer test, using the method Enzyme Linked Fluorescent Assay (ELFA), in the diagnostic of acute venous thromboembolism. Methods: In 89 patients with signals and symptoms suggestive of pulmonary thromboembolism and/or deep vein thrombosis had been carried through measure D dimer by technique ELFA equipment VIDAS® - BioMérieux. The values of sensibility, accuracy specificity, predictive values positive and negative and of the test had been calculated, as well as curve ROC of the sample studied. All the patients had been submitted the image exams for the confirmation of the acute thromboembolism event. It was calculated kappa ratio to compare D dimer test results with image exams results. Results: Between 89 studied patients (mean of age 54.3 years; 51 women), 36 (40.4%) they had presented and 53 had not presented acute thrombosis (59.6%). It enters the patients without acute thromboembolism 15 (28.3%) had presented resulted negative of D dimer. All patients with thrombosis had presented resulted positive of D dimer. The test presented 100% sensibility; 28.3% of specificity; positive predictive value was 48.6%; 100% of negative predictive value and accuracy value was 57.3%. The area under the curve (AUC) to total sample studied was 0.734, it was showed that the test have a good prediction to acute thrombosis. The kappa ratio value was 0.24 (p<0.001) showing a bad concordat n to thrombosis diagnostic. Conclusion: The measure of D dimer by method ELFA was able to exclude the diagnostic of acute venous thromboembolism in this sample studied. The results obtained in this sample studied let to conclude that the D dimer test in patients with suspected of acute thromboembolism presented high sensibility to diagnostic of this disease.
|
48 |
Novel Diagnostic and Prognostic Methods for Cancer and Cancer Associated ThrombosisOto Martínez, Ana Julia 02 August 2023 (has links)
Tesis por compendio / [ES] El cáncer constituye la segunda causa de muerte en España. El tromboembolismo venoso (TEV), una complicación del cáncer, conlleva gran gasto del presupuesto sanitario y representa la segunda causa de muerte en estos pacientes. Sin embargo, las herramientas actuales disponibles para la identificación de pacientes oncológicos con elevado riesgo trombótico son limitadas. Adicionalmente, no existen métodos simples, mínimamente invasivos y económicos de diagnóstico de cáncer vesical. Por este motivo, se utilizan técnicas dañinas como la tomografía computarizada la cual implica una elevada dosis de exposición a radiación y procedimientos invasivos como la cistoscopia. Además, un estado hipercoagulable parece tener una relación directa con una mayor carga tumoral y un peor pronóstico. El objetivo principal de la presente Tesis Doctoral es explorar la utilidad clínica de nuevos métodos diagnósticos y pronósticos para el cáncer y sus complicaciones trombóticas. En la primera parte de la Tesis, nos hemos centrado en el papel de miRNAs en orina como biomarcadores de cáncer vesical. Hemos identificado al miR-29c-3p como el miRNA más estable por lo que fue utilizado como normalizador. Hemos ajustado un modelo de regresión logística ordinal para el diagnóstico y estratificación de cáncer vesical utilizando la expresión de miRNAs en orina de pacientes y controles. Este modelo incluyó la expresión de 7 miRNAs: miR-221-3p, miR-93-5p, miR-362-3p, miR-191-5p, miR-200c-3p, miR-192-5p y miR-21-5p. En la segunda parte de la Tesis, nos centramos en el estudio de nuevos biomarcadores para la trombosis asociada a cáncer. Analizamos el potencial predictivo de los miRNAs y de marcadores de activación de neutrófilos en pacientes con cáncer pancreático y pacientes con glioma y meningioma. En cáncer pancreático, obtuvimos un perfil de 7 miRNAs (miR-486-5p, miR-106b-5p, let-7i-5p, let-7g-5p, miR-144-3p, miR-19a-3p y miR-103a-3p) capaz de estimar el riesgo de TEV al diagnóstico con dianas incluidas en las rutas pancreatic cancer y complement and coagulation cascades. En el estudio de los marcadores de activación de neutrófilos, obtuvimos un nuevo modelo predictivo de TEV con la calprotectina como variable predictora. Respecto al estudio de trombosis asociada a cáncer en tumores intracraneales, en pacientes con glioma, ajustamos y validamos un modelo predictivo de embolismo pulmonar (EP) postquirúrgico con 6 miRNAs: miR-363-3p, miR-93-3p, miR-22-5p, miR-451a, miR-222-3p y miR-140-3p y otro con cfDNA y mieloperoxidasa como predictores. Además, hemos combinado los dos tipos de marcadores y hemos obtenido un modelo con mayor capacidad predictiva que incluye a miR-140-3p y a la mieloperoxidasa como predictores. En pacientes con meningioma, ajustamos y validamos un modelo predictivo de EP postquirúrgico con 6 miRNAs: miR-29a-3p, miR-660-5p, miR-331-3p, miR-126-5p, miR-23a-3p y miR-23b-3p. En conclusión, proponemos diferentes perfiles de biomarcadores para el diagnóstico de cáncer de vejiga y para la identificación de pacientes oncológicos con elevado riesgo de trombosis. / [CA] El càncer constitueix la segona causa de mort a Espanya. El tromboembolisme venós (TEV), una complicació del càncer, representa la segona causa de mort en aquests pacients i comporta una gran despesa sanitària. No obstant això, les eines disponibles actualment per a la identificació de pacients oncològics amb elevat risc trombòtic són limitades. Actualment, no existeixen mètodes diagnòstics per al càncer de bufeta senzills, mínimament invasius i econòmics. Per aquest motiu, s'utilitzen tècniques nocives com la tomografia computada la qual implica una elevada dosi d'exposició a radiació i procediments invasius com la cistoscòpia. A més, un estat hipercoagulable sembla tindre una relació directa amb una major càrrega tumoral i un pitjor pronòstic. L'objectiu principal de la present Tesi Doctoral fou explorar la utilitat clínica de nous mètodes diagnòstics i pronòstics per al càncer i les seues complicacions trombòtiques. En la primera part de la Tesi, ens hem centrat en el paper dels microRNAs (miRNAs) en orina com biomarcadors de càncer de bufeta. Hem identificat al miR-29c-3p com el miRNA més estable per la qual cosa va ser utilitzat com a normalitzador. Hem ajustat un model de regressió logística ordinal per al diagnòstic i estratificació de càncer de bufeta utilitzant l'expressió de miRNAs en orina de pacients i controls. Aquest model va incloure l'expressió de 7 miRNAs: miR-221-3p, miR-93-5p, miR-362-3p, miR-191-5p, miR-200c-3p, miR-192-5p i miR-21-5p. En la segona part de la Tesi, ens centràrem en l'estudi de nous biomarcadors per a la trombosi associada a càncer. Analitzàrem el potencial predictiu dels miRNAs i de marcadors d'activació de neutròfils en pacients amb càncer pancreàtic i pacients amb glioma i meningioma. En càncer pancreàtic, vàrem obtindre un perfil de 7 miRNAs (miR-486-5p, miR-106b-5p, let-7i-5p, let-7g-5p, miR-144-3p, miR-19a-3p i miR-103a-3p) capaç d'estimar el risc de TEV al diagnostic dels pacients els quals tenen dianes incloses en les rutes biològiques pancreatic cancer y complement and coagulation cascades. En el estudi dels marcadors d¿activació de neutròfils, vàrem obtenir un altre model predictiu de TEV amb la calprotectina com a variable predictora. Respecte a l'estudi de trombosi associada a càncer en tumors intracranials, en pacients amb glioma, ajustàrem i validàrem un model predictiu d'embolisme pulmonar (EP) incidental postquirúrgic amb 6 miRNAs (miR-363-3p, miR-93-3p, miR-22-5p, miR-451a, miR-222-3p i miR-140-3p) i un altre amb cfDNA i mieloperoxidasa com a predictors. A més, vàrem combinar els dos tipus de marcadors i vàrem obtenir un model amb major capacitat predictiva que inclou al miR-140-3p i la mieloperoxidasa com a predictors. En pacients amb meningioma, ajustàrem i validàrem un model predictiu d¿EP incidental postquirúrgic amb 6 miRNAs: miR-29a-3p, miR-660-5p, miR-331-3p, miR-126-5p, miR-23a-3p i miR-23b-3p. En conclusió, proposem diferents perfils de biomarcadors per al diagnòstic de càncer de bufeta i per a la identificació de pacients oncològics amb elevat risc de trombosi. / [EN] Cancer is the second leading cause of death in Spain. Collaterally, venous thromboembolism (VTE), as a complication of cancer, consumes a great part of its healthcare budget and, more importantly, it is the second cause of death in these patients. However, limited tools are available to identify high risk patients. Additionally, a simple, minimally invasive and economical diagnostic methods for bladder cancer are also lacking. For that aim, harmful techniques are used like CT scan with high radiation exposure and invasive procedures like cystoscopy. Moreover, a hypercoagulable state seems directly related to a large tumor burden and poor prognosis. The overall aim of this Doctoral Thesis is to explore the clinical utility of novel diagnostic and prognostic methods for cancer and its thrombotic complications. In the first part of this Doctoral Thesis, we focused on the role of urine miRNAs as bladder cancer biomarkers. We identified miR-29c-3p as the most stable miRNA and was therefore used as normalizer. We adjusted an ordinal logistic regression model for the diagnosis and stratification of BC using the urine miRNA expression levels of patients and controls. This model included 7 miRNAs: miR-221-3p, miR-93-5p, miR-362-3p, miR-191-5p, miR-200c-3p, miR-192-5p and miR-21-5p. In the second part of this Doctoral Thesis, we focused on the study of novel biomarkers for cancer-associated thrombosis. We analyzed the predictive potential of miRNAs and neutrophil activation markers of thrombotic events in patients with pancreatic cancer and patients with glioma and meningioma. In pancreatic cancer, we obtained a profile of 7 miRNAs (miR-486-5p, miR-106b-5p, let-7i-5p, let-7g-5p, miR-144-3p, miR-19a-3p and miR-103a-3p) able to estimate the risk of potential VTE at diagnosis with targets involved in the pancreatic cancer and complement and coagulation cascades pathways. In the study of the neutrophil activation makers, we obtained a new predictive model of VTE with calprotectin as predictor. Regarding the study of cancer-associated thrombosis in intracranial tumors, in glioma patients, we adjusted and validated a predictive model for post-surgical pulmonary embolism (PE) with 6 miRNAs: miR-363-3p, miR-93-3p, miR-22-5p, miR-451a, miR-222-3p and miR-140-3p, and another with cfDNA and myeloperoxidase as predictors. Furthermore, we combined both types of biomarkers and obtained an improved model using myeloperoxidase and miR-140-3p as predictors. In meningioma patients we fitted and validated a predictive model with 6 miRNAs: miR-29a-3p, miR-660-5p, miR-331-3p, miR-126-5p, miR-23a-3p and miR-23b-3p. In conclusion, we propose several profiles of biomarkers for the diagnosis of bladder cancer and for the identification of oncologic patients at high risk of suffering a thrombotic event. / Oto Martínez, AJ. (2022). Novel Diagnostic and Prognostic Methods for Cancer and Cancer Associated Thrombosis [Tesis doctoral]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/181510 / Compendio
|
49 |
Estudo prospectivo de eventos tromboembólicos após reoperações de alta complexidade em estimulação cardíaca artificial definitiva / Prospective study of thromboembolic events after high complexity reoperation in permanent artificial cardiac pacingAlbertini, Caio Marcos de Moraes 07 December 2017 (has links)
INTRODUÇÃO: Estenose e obstruções venosas são achados frequentes após o implante de cabos-eletrodos transvenosos. Manifestações clínicas dessas lesões venosas, entretanto, são raramente reportadas. Embora exista consenso de que fenômenos tromboembólicos sejam mais comuns após reoperações que envolvam o implante de novos cabos-eletrodos ou procedimentos de extração transvenosa, ainda não existem evidências que comprovem essa observação. OBJETIVOS: Em pacientes submetidos a reoperações para corrigir disfunção em cabos-eletrodos ou para mudar o modo de estimulação, o estudo visou identificar: a) a incidência de tromboembolia pulmonar (TEP) e de trombose venosa profunda (TVP) do membro superior ipsilateral ao procedimento; b) a prevalência de lesões venosas prévias ao procedimento cirúrgico, pelo estudo venográfico, e a ocorrência de modificações desse padrão seis meses após o procedimento; e c) fatores prognósticos para a ocorrência dos eventos clínicos e das alterações venográficas. MÉTODOS: No período de abril de 2013 a julho de 2016 foram estudados 84 pacientes. A avaliação pré-operatória incluiu: ultrassonografia com doppler dos membros superiores, angiotomografia de tórax com protocolo para TEP, venografia por subtração digital e coleta de biomarcadores laboratoriais específicos do sistema de coagulação e hemostasia. Os exames diagnósticos foram repetidos no momento pós-operatório para detectar os desfechos do estudo. Todos os pacientes foram acompanhados por 12 meses. Os desfechos primários foram a ocorrência de TEP ou TVP em até 30 dias após o procedimento. Os desfechos secundários foram as alterações venográficas no sexto mês após a intervenção cirúrgica. Na análise da associação das variáveis demográficas, clínicas, operatórias e laboratoriais com os desfechos do estudo, empregou-se os testes Qui-quadrado, Exato de Fisher ou \"t\" de Student. Modelos de regressão logística multivariados foram utilizados para identificar fatores prognósticos. RESULTADOS: Entre os 84 pacientes incluídos, houve equilíbrio entre os sexos e a idade média de 59,3 ± 15,2 anos. O principal motivo para realizar o procedimento cirúrgico foi a disfunção de cabos-eletrodos (75%). A remoção de cabos-eletrodos foi efetuada em 52,4% dos casos. A taxa de eventos clínicos e subclínicos pós-operatórios foi de 35,7%, representada por TVP em 24 (28,6%) casos e TEP em seis (7,1%). Alterações no padrão venográfico seis meses após a operação foram identificadas em 34,5% dos pacientes. Os fatores prognósticos independentes para TVP foram: a presença de circulação colateral significativa na venografia pré-operatória ([odds ratio (OR) = 4,7]), (intervalo de confiança de 95% (IC 95%); 1,1 - 19,8; P = 0,037), a extração transvenosa de cabos-eletrodos (OR = 27,4; IC 95%; 5,8 - 128,8; P < 0,0001) e o aumento do fibrinogênio no pós-operatório (OR = 1,02; IC 95%; 1,01 - 1,03; P = 0,018). O histórico de tabagismo foi o único fator prognóstico relacionado com a ocorrência de TEP (OR = 14,6; IC 95%; 2,3 - 91,8; P = 0,004). Somente a extração transvenosa de cabos-eletrodos foi fator prognóstico independente (OR = 5,0; IC 95%; 1,6 - 15,4; P = 0,004) para alterações venográficas pós-operatórias. CONCLUSÃO: Reoperações envolvendo o manuseio de território venoso com cabos-eletrodos previamente implantados apresentam elevados índices de complicações tromboembólicas e de alterações venográficas. Extração transvenosa de cabos-eletrodos apresentou impacto significativo no desenvolvimento de TVP e de alterações venográficas. Esses resultados mostram a necessidade de novos estudos específicos para avaliar o papel de estratégias preventivas para esse subgrupo de pacientes / INTRODUCTION: Venous stenosis or occlusion is a frequent finding in patients with previously-implanted transvenous leads. Clinical manifestations of these venous lesions, however, are rarely reported. Although there is a consensus that thromboembolic events are more frequent after reoperation involving the implantation of new leads or lead removal, there is still no evidence to support this observation. OBJECTIVES: In patients submitted to reoperations due to lead dysfunction or device upgrade, the study aimed to determine: a) the incidence of pulmonary embolism (PE) and upper extremity deep venous thrombosis (UEDVT) ipsilateral to the cardiac device; b) the prevalence of venous lesions determined by preoperative venography, and the occurrence of modifications or progression of these lesions six months after the procedure; and c) prognostic factors for clinical and venographic outcomes. METHODS: From April/2013 to July/2016, 84 patients were studied. The preoperative evaluation included: upper extremity venous ultrasound, computed tomography pulmonary angiography, digital subtraction venography and specific laboratory tests for coagulation and hemostasis. Diagnostic exams were repeated postoperatively to detect the study outcomes. All patients were followed for 12 months. Primary outcomes were occurrence of PE or UEDVT within 30 days after the procedure. Secondary outcomes were venographic changes six months after the surgical intervention. Student\'s t test, Chi-square or Fisher\'s Exact test were used in the univariate analysis of demographic, clinical, operative and laboratory variables. Multivariate logistic regression models were used to identify prognostic factors. RESULTS: Among the 84 patients included, there was a balance between gender and the mean age was 59.3 ± 15.2 years. Lead malfunctioning (75%) was the main surgical procedure indication. Lead removal was performed in 52.4% of the cases. The rate of postoperative clinical and subclinical events was 35.7%, represented by UEDVT in 24 (28.6%) cases and PE in 6 (7.1%). Alterations in the venography findings six months after the surgery were identified in 34.5% of the patients. Independent prognostic factors for UEDVT were: the presence of significant collateral circulation in the preoperative venography ([odds ratio (OR)= 4.7; [95% confidence interval (CI): 1.1 - 19.8; P=0.037), transvenous lead extraction (OR= 27.4; 95% CI 5.8-128.8; P < 0.0001) and fibrinogen variation (OR= 1.02; 95% CI 1.01 - 1.03; P=0.018). Smoking history was the only prognostic factor related to the occurrence of PE (OR= 14.6; 95% CI 2.3 - 91.8; P=0,004). Transvenous lead extraction was the only independent prognostic factor (OR= 5.0; 95% CI 1.6 - 15.4; P=0.004) for postoperative venographic endpoints. CONCLUSION: Reoperations involving previously transvenous implanted leads present high rates of thromboembolic complications and venographic alterations. Transvenous lead extraction had a significant impact on the development of UEDVT and venographic alterations. These results show the need for further studies to evaluate the role of preventive strategies for this subgroup of patients
|
50 |
Estudo prospectivo de eventos tromboembólicos após reoperações de alta complexidade em estimulação cardíaca artificial definitiva / Prospective study of thromboembolic events after high complexity reoperation in permanent artificial cardiac pacingCaio Marcos de Moraes Albertini 07 December 2017 (has links)
INTRODUÇÃO: Estenose e obstruções venosas são achados frequentes após o implante de cabos-eletrodos transvenosos. Manifestações clínicas dessas lesões venosas, entretanto, são raramente reportadas. Embora exista consenso de que fenômenos tromboembólicos sejam mais comuns após reoperações que envolvam o implante de novos cabos-eletrodos ou procedimentos de extração transvenosa, ainda não existem evidências que comprovem essa observação. OBJETIVOS: Em pacientes submetidos a reoperações para corrigir disfunção em cabos-eletrodos ou para mudar o modo de estimulação, o estudo visou identificar: a) a incidência de tromboembolia pulmonar (TEP) e de trombose venosa profunda (TVP) do membro superior ipsilateral ao procedimento; b) a prevalência de lesões venosas prévias ao procedimento cirúrgico, pelo estudo venográfico, e a ocorrência de modificações desse padrão seis meses após o procedimento; e c) fatores prognósticos para a ocorrência dos eventos clínicos e das alterações venográficas. MÉTODOS: No período de abril de 2013 a julho de 2016 foram estudados 84 pacientes. A avaliação pré-operatória incluiu: ultrassonografia com doppler dos membros superiores, angiotomografia de tórax com protocolo para TEP, venografia por subtração digital e coleta de biomarcadores laboratoriais específicos do sistema de coagulação e hemostasia. Os exames diagnósticos foram repetidos no momento pós-operatório para detectar os desfechos do estudo. Todos os pacientes foram acompanhados por 12 meses. Os desfechos primários foram a ocorrência de TEP ou TVP em até 30 dias após o procedimento. Os desfechos secundários foram as alterações venográficas no sexto mês após a intervenção cirúrgica. Na análise da associação das variáveis demográficas, clínicas, operatórias e laboratoriais com os desfechos do estudo, empregou-se os testes Qui-quadrado, Exato de Fisher ou \"t\" de Student. Modelos de regressão logística multivariados foram utilizados para identificar fatores prognósticos. RESULTADOS: Entre os 84 pacientes incluídos, houve equilíbrio entre os sexos e a idade média de 59,3 ± 15,2 anos. O principal motivo para realizar o procedimento cirúrgico foi a disfunção de cabos-eletrodos (75%). A remoção de cabos-eletrodos foi efetuada em 52,4% dos casos. A taxa de eventos clínicos e subclínicos pós-operatórios foi de 35,7%, representada por TVP em 24 (28,6%) casos e TEP em seis (7,1%). Alterações no padrão venográfico seis meses após a operação foram identificadas em 34,5% dos pacientes. Os fatores prognósticos independentes para TVP foram: a presença de circulação colateral significativa na venografia pré-operatória ([odds ratio (OR) = 4,7]), (intervalo de confiança de 95% (IC 95%); 1,1 - 19,8; P = 0,037), a extração transvenosa de cabos-eletrodos (OR = 27,4; IC 95%; 5,8 - 128,8; P < 0,0001) e o aumento do fibrinogênio no pós-operatório (OR = 1,02; IC 95%; 1,01 - 1,03; P = 0,018). O histórico de tabagismo foi o único fator prognóstico relacionado com a ocorrência de TEP (OR = 14,6; IC 95%; 2,3 - 91,8; P = 0,004). Somente a extração transvenosa de cabos-eletrodos foi fator prognóstico independente (OR = 5,0; IC 95%; 1,6 - 15,4; P = 0,004) para alterações venográficas pós-operatórias. CONCLUSÃO: Reoperações envolvendo o manuseio de território venoso com cabos-eletrodos previamente implantados apresentam elevados índices de complicações tromboembólicas e de alterações venográficas. Extração transvenosa de cabos-eletrodos apresentou impacto significativo no desenvolvimento de TVP e de alterações venográficas. Esses resultados mostram a necessidade de novos estudos específicos para avaliar o papel de estratégias preventivas para esse subgrupo de pacientes / INTRODUCTION: Venous stenosis or occlusion is a frequent finding in patients with previously-implanted transvenous leads. Clinical manifestations of these venous lesions, however, are rarely reported. Although there is a consensus that thromboembolic events are more frequent after reoperation involving the implantation of new leads or lead removal, there is still no evidence to support this observation. OBJECTIVES: In patients submitted to reoperations due to lead dysfunction or device upgrade, the study aimed to determine: a) the incidence of pulmonary embolism (PE) and upper extremity deep venous thrombosis (UEDVT) ipsilateral to the cardiac device; b) the prevalence of venous lesions determined by preoperative venography, and the occurrence of modifications or progression of these lesions six months after the procedure; and c) prognostic factors for clinical and venographic outcomes. METHODS: From April/2013 to July/2016, 84 patients were studied. The preoperative evaluation included: upper extremity venous ultrasound, computed tomography pulmonary angiography, digital subtraction venography and specific laboratory tests for coagulation and hemostasis. Diagnostic exams were repeated postoperatively to detect the study outcomes. All patients were followed for 12 months. Primary outcomes were occurrence of PE or UEDVT within 30 days after the procedure. Secondary outcomes were venographic changes six months after the surgical intervention. Student\'s t test, Chi-square or Fisher\'s Exact test were used in the univariate analysis of demographic, clinical, operative and laboratory variables. Multivariate logistic regression models were used to identify prognostic factors. RESULTS: Among the 84 patients included, there was a balance between gender and the mean age was 59.3 ± 15.2 years. Lead malfunctioning (75%) was the main surgical procedure indication. Lead removal was performed in 52.4% of the cases. The rate of postoperative clinical and subclinical events was 35.7%, represented by UEDVT in 24 (28.6%) cases and PE in 6 (7.1%). Alterations in the venography findings six months after the surgery were identified in 34.5% of the patients. Independent prognostic factors for UEDVT were: the presence of significant collateral circulation in the preoperative venography ([odds ratio (OR)= 4.7; [95% confidence interval (CI): 1.1 - 19.8; P=0.037), transvenous lead extraction (OR= 27.4; 95% CI 5.8-128.8; P < 0.0001) and fibrinogen variation (OR= 1.02; 95% CI 1.01 - 1.03; P=0.018). Smoking history was the only prognostic factor related to the occurrence of PE (OR= 14.6; 95% CI 2.3 - 91.8; P=0,004). Transvenous lead extraction was the only independent prognostic factor (OR= 5.0; 95% CI 1.6 - 15.4; P=0.004) for postoperative venographic endpoints. CONCLUSION: Reoperations involving previously transvenous implanted leads present high rates of thromboembolic complications and venographic alterations. Transvenous lead extraction had a significant impact on the development of UEDVT and venographic alterations. These results show the need for further studies to evaluate the role of preventive strategies for this subgroup of patients
|
Page generated in 0.1728 seconds