• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 22
  • Tagged with
  • 22
  • 22
  • 22
  • 18
  • 16
  • 9
  • 9
  • 9
  • 8
  • 8
  • 8
  • 8
  • 8
  • 6
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Estudo clínico randomizado para profilaxia das complicações tromboembólicas pós-implante transvenoso de dispositivos cardíacos eletrônicos em pacientes de alto risco / Randomized controlled clinical trial for the prevention of thromboembolic complications after transvenous cardiac devices implantation in high risk patients

Katia Regina da Silva 11 July 2008 (has links)
I ntrodução: A incidência de lesões venosas pós-implante transvenoso de dispositivos cardíacos eletrônicos implantáveis (DCEI) é elevada, sendo a disfunção ventricular e o uso prévio de marcapasso temporário (MPT) ipsilateral ao implante definitivo fatores de risco independentes para sua ocorrência. A utilidade de estratégias terapêuticas profiláticas para a prevenção dessa complicação ainda permanece controversa. O objetivo desse estudo clínico, randomizado e controlado foi avaliar o papel da anticoagulação oral na prevenção das lesões venosas pós-implante transvenoso de DCEI em pacientes de alto risco, analisando a influência na incidência das obstruções venosas, a segurança, a eficácia e as complicações do tratamento. Método: No período de Fevereiro/2004 a Setembro/2007 foram estudados 101 pacientes adultos submetidos ao primeiro implante transvenoso de DCEI, apresentando fração de ejeção do ventrículo esquerdo (FEVE) <=0,40 e/ou presença de MPT ipsilateral ao implante definitivo. Após o procedimento, os pacientes foram randomizados para o uso diário de placebo ou varfarina. Avaliações clínicas e laboratoriais foram realizadas periodicamente. A pesquisa de lesões venosas foi feita pela venografia por subtração digital, seis meses após o implante. A análise dos dados foi realizada segundo o princípio de \"intenção-de-tratar\". Na análise da associação das variáveis demográficas, clínicas e operatórias com a presença de lesões venosas empregou-se os testes Qui-quadrado, Exato de Fisher ou \"t\" de Student e o modelo de regressão logística foi utilizado para a identificação de fatores de risco. Resultados: As características basais foram similares nos dois grupos, não sendo encontradas diferenças significativas entre as variáveis demográficas, clínicas e operatórias. Durante o período de seguimento clínico, ocorreram seis óbitos, quatro relacionados com a progressão da insuficiência cardíaca e duas mortes súbitas. Do total de óbitos, quatro pacientes estavam alocados no Grupo Varfarina e dois no Placebo. Somente um paciente, do Grupo Varfarina, apresentou sangramento gastrintestinal, com necessidade de hospitalização e transfusão de hemoderivados. O valor médio do INR dos pacientes do Grupo Varfarina foi 2,3±0,7 enquanto que no Grupo Placebo foi 1,1±0,3, sendo que esta diferença manteve-se ao longo de todo o período de seguimento. O valor médio da hemoglobina e do hematócrito foi similar em ambos os grupos, sendo 13,9±1,6g/dL e 41,2±4,6%, no Grupo Placebo e 14,0±1,4g/dL e 41,9±3,7%, no Grupo Varfarina. Dos pacientes alocados no Grupo Varfarina, 17 (38,6%) apresentaram obstruções venosas, em comparação a 29 (60,4%) casos do Grupo Placebo, com redução absoluta do risco de 22% (RR= 0,63; IC 95%= 0,013 a 0,42). A comparação das características clínicas dos pacientes que apresentaram lesões venosas com as dos pacientes que não apresentaram mostrou que o uso de varfarina (P=0,037) esteve associado a uma menor incidência de lesões venosas e a presença da doença de Chagas (P= 0,051) esteve associada a uma maior incidência. Somente a ausência de anticoagulação oral foi identificada como fator de risco independente para a ocorrência das lesões venosas (OR= 2,424; IC 95% 1,048 - 5,606; P= 0,038). Conclusão: O uso profilático da anticoagulação mostrou-se seguro e reduziu significativamente a incidência de obstruções venosas pós-implante de DCEI nos pacientes de alto risco. / Introduction: The incidence of venous thrombosis after cardiac devices implantation is high. Ventricular dysfunction and previous transvenous temporary leads ipsilaterally to the permanent implantation are independent risk factors. The effect of prophylactic strategies to prevent these complications remains controversial. The aim of this clinical, randomized and controlled study was to evaluate the role of oral anticoagulant therapy in the prevention of these complications in high risk patients, analyzing the effect on the venous obstructions incidence, the safety, effectiveness and complications of this treatment. Method: Between February 2004 and September 2007, 101 adult patients submitted to first transvenous cardiac devices implantation, with left ventricular ejection fraction <=0.40 and/or previous transvenous temporary leads were evaluated. After device implantation, patients were randomly assigned to receive either placebo or warfarin. Periodical clinical and laboratorial evaluations were performed to anticoagulant management. Following the six-month period, every patient was submitted to a digital subtraction venography. Data analysis was performed according to the \"intention-to-treat\" principle. The association of demographic, clinical and procedure variables with the presence of venous lesions was analyzed by the Chi-square, Fisher\'s exact, or \"t\" Student tests, and logistic regression model was used to identify risk factors. Results: Baseline characteristics were similar in both groups and no significant difference was observed in demographic, clinical and procedure variables. During the follow-up period, six patients died, four related to heart failure progression and two of sudden death. Four of the patients dead were allocated in Warfarin group and two in Placebo group. Only one patient of the Warfarin group presented with gastrointestinal bleeding, requiring hospitalization and blood transfusion. The median INR of patients in the Warfarin group was 2.3 ± 0.7, whereas the median INR in the Placebo group was 1.1 ± 0.3. This difference was maintained throughout the study period. The median hemoglobin and hematocrit values were similar in both groups, with 13.9 ± 1.6g / dL and 41.2 ± 4.6% in the Placebo group and 14.0 ± 1.4g / dL and 41.9 ± 3.7% in the Warfarin group. The frequency of venous obstructions in the Warfarin group was 38.6% compared with 60.4% in the Placebo group (P=0.018), corresponding to an absolute risk reduction of 22% (RR= 0.63, 95% CI= 0.013-0.42). The comparison between obstructed and non-obstructed patients showed that warfarin use was associated with a lower incidence of venous lesions (P= 0.037) and that Chagas\' disease presence was associated with a higher incidence (P= 0.051). Logistic regression analysis showed that only absence of anticoagulant therapy (P=0.038; OR=2.424, 95% CI= 1.048 - 5.606) was a predictor of venous obstruction. Conclusion: The prophylactic use of the anticoagulation therapy has been safe and reduced the frequency of venous thrombosis after transvenous cardiac devices implantation in high risk patients.
12

Efeitos da terapia de ressincronização cardíaca no remodelamento ventricular reverso de pacientes com cardiopatia dilatada não isquêmica: avaliação pela ecocardiografia tridimensional / Effects of cardiac resynchronization therapy on left ventricular reverse remodeling in patients with non ischemic dilated myocardiopathy: evaluation by three dimensional echocardiography

Viviane Tiemi Hotta 18 June 2010 (has links)
Introdução: A terapia de ressincronização cardíaca (TRC) tem se mostrado como um tratamento eficaz no tratamento de pacientes com insuficiência cardíaca (IC) grave e distúrbio da condução ventricular. A ecocardiografia tridimensional (Eco 3D) consiste em uma nova modalidade diagnóstica com resultados promissores para a identificação da dissincronia cardíaca e avaliação dos resultados da TRC. Objetivos: Estudar os efeitos da TRC no remodelamento reverso do ventrículo esquerdo (VE), em pacientes com miocardiopatia não isquêmica, insuficiência cardíaca e distúrbio da condução intraventricular, por meio da ecocardiografia tridimensional em tempo real. Métodos: De janeiro de 2007 a junho de 2009, foram avaliados 24 pacientes com miocardiopatia dilatada não isquêmica, IC classe funcional (CF) III ou IV (NYHA), com tratamento medicamentoso otimizado, QRS > 120 ms ao eletrocardiograma, e fração de ejeção do ventrículo esquerdo (FEVE) < 0,35 submetidos à TRC. Os pacientes foram avaliados antes, três e seis meses após TRC pela CF (NYHA), qualidade de vida pelo escore de Minnesota (MLHFQ), eletrocardiograma (intervalo PR e duração do QRS), ecocardiograma bidimensional (volumes diastólico VDVE, e sistólico VSVE, do ventrículo esquerdo, fração de ejeção ventricular esquerda - FEVE), Doppler tecidual (TDI) (avaliação da dissincronia cardíaca) e análise tridimensional (VDVE, VSVE, FEVE e dissincronia pela análise do SDI systolic dyssynchrony index). Foi considerado remodelamento reverso redução > 15% do VSVE após a TRC. As diferenças das médias das variáveis contínuas foram analisadas com o teste T não pareado, entre os grupos respondedor e não respondedor, depois de satisfeita a condição de normalidade. Antes da TRC, foi realizada uma análise univariada das características clínicas, eletrocardiográficas e ecocardiográficas para a construção de um modelo de regressão logística. Resultados: 9/24(38%) dos pacientes analisados apresentaram remodelamento ventricular reverso após TRC. O grupo respondedor apresentou menores volumes ventriculares (VDVE: 230 + 35 ml vs 316 + 10 ml, p = 0,045; VSVE: 178 + 30 ml vs 238 + 10 ml, p = 0,047), avaliados pelo método de Simpson, além de maior dissincronia cardíaca, avaliada pelo Eco 3D (SDI:13 + 3% vs 9 + 3%, p = 0,005) e pelo TDI (138 + 31 ms vs 102 + 37 ms, p = 0,026). Após a análise de regressão logística, o SDI (SDI > 11%) foi o único fator independente na predição de remodelamento reverso, seis meses após a TRC (sensibilidade:0,78; especificidade:0,79). Conclusões: O Eco 3D foi eficaz na detecção do remodelamento reverso do VE após a TRC, por meio da detecção da redução dos volumes ventriculares esquerdos (VDVE, VSVE) e da melhora da FEVE. O SDI foi o único preditor independente de remodelamento reverso após a TRC. Apresentaram menor taxa de resposta seis meses após a TRC, os pacientes com maiores volumes ventriculares esquerdos e menor fração de ejeção ventricular esquerda. A TRC melhorou a CF (NYHA) de IC e a qualidade de vida pelo escore de Minnesota / Introduction: Cardiac resynchronization therapy (CRT) consists of an effective treatment for patients with severe heart failure and ventricular conduction disturbance. Three dimensional echocardiography (3D Echo) is a new diagnostic modality with promising results in the identification of cardiac dyssynchrony and for the evaluation of CRT results. Objectives: To evaluate the effects of CRT in the left ventricular (LV) reverse remodeling in patients with non ischemic dilated myocardiopathy, heart failure and intraventricular conduction disturbance by using three dimensional echocardiography. Methods: From January, 2007 to June, 2009, twenty-four consecutive patients with heart failure, sinus rhythm, QRS > 120 ms, and Functional Class III or IV (NYHA), despite optimized medical treatment and left ventricular ejection fraction (LVEF) < 0,35, underwent CRT. All patients were assessed regarding Functional Class (NYHA), and the quality of life was evaluated using the Minnesota Living with Heart Failure Questionnaire (MLHFQ). All patients were submitted to an electrocardiogram, two dimensional echocardiography (2D Echo) including the evaluation of cardiac dyssynchrony by Tissue Doppler Imaging (TDI) and 3D Echo (SDI - systolic dyssynchrony index), before, three and six months after CRT. Left ventricular reverse remodeling was defined as a reduction of at least 15% of the left ventricular systolic volume (LVSV) after CRT. The difference between the mean of the continuous variables were compared by students T test, after being tested for normality. Before CRT, it was performed a univariate analysis of clinical, electrocardiographic and echocardiographic baseline characteristics of the patients for the construction of a logistic regression model. Results: 9/24 (38%) of the patients presented with left ventricular reverse remodeling six months after CRT. Patients who presented LV reverse remodeling had smaller left ventricular volumes estimated by Simpsons rule (LV diastolic volume (LVDV): 230 + 35 ml vs 316 + 10 ml, p = 0,045; LVSV: 178 + 30 ml vs 238 + 10 ml, p = 0,047) and greater cardiac dyssynchrony detected by 3D Echo (SDI: 13 + 3% vs 9 + 3%, p = 0,005) and by TDI (138 + 31 ms vs 102 + 37 ms, p = 0,026). After logistic regression analysis, the best predictors of left ventricular reverse remodeling after CRT were the cardiac dyssynchrony indexes evaluated by TDI (twelve segments) and SDI, but SDI (SDI > 11%) was the only independent factor in the prediction of left ventricular reverse remodeling six months after CRT (sensitivity of 0,78 and specificity of 0,79). Conclusions: 3D Echo was effective in the detection of left ventricular reverse remodeling after CRT, by detecting the reduction in left ventricular volumes (LVDV, LVSV) and the increase in LVEF. SDI was the only independent predictor of LV reverse remodeling after CRT. Patients with larger LV volumes, and smaller LVEF were more prone to not respond six months after CRT. CRT improved Functional Class (NYHA) and quality of life evaluated by MLHFQ
13

Avaliação da qualidade de vida de portadores de marcapasso cardíaco artificial em Goiânia, Goiás / Quality of life of artificial cardiac pacemaker patient in Goiânia, Goiás

ZATTA, Laidilce Teles 14 April 2010 (has links)
Made available in DSpace on 2014-07-29T15:04:27Z (GMT). No. of bitstreams: 1 dissertacao Laidilce T Zatta.pdf: 353033 bytes, checksum: 50158c4aade92a4a9fe7e29429d42d86 (MD5) Previous issue date: 2010-04-14 / Health related quality of life includes social, emotional and physical well-being of individuals, the impact of some treatments used to control health problems and the individual's ability to lead his own life. One of these treatments currently used is a device called artificial pacemaker, and patients have reported changes in daily life after implantation, which may influence the quality of their lives. It is a descriptive exploratory study that aimed to evaluate the quality of life of cardiac pacemakers patients using a generic instrument- SF-36 ® (Medical Outcomes Study 36-Item Short-Form Health Survey) and other specific instrument - AQUAREL (Assessment of Quality of Life and Related Events). We interviewed 84 patients with permanent pacemaker after six or more months of implantation, and used two instruments to assess quality of life: SF-36 and AQUAREL. Respondents had an average age 59.9 years, 58.3% were female, catholic (70.2%), had completed elementary school (81%). They self-reported themselves as white (59.5%), they had a steady partner (69%) and monthly family income below two minimum wages (51.3%). The implantation time varied between one and 28 years (median three years), the principal cause was the Chagas disease (76.2%), 73.8% were with the first generator, the predominant type of stimulation was DDDR (67,9%) and they were functional class I (57.1%). The median scores for SF-36 dimensions were higher in Social Functioning (100.00) and Mental Health (68.00) dimensions; the lowest scores were obtained in Role Limitations Resulting from Physical Health (00.00) and Role Limitations Resulting from Emotional Problems (33.33) dimensions. The median scores of AQUAREL were 81.25 for Chest Discomfort, Arrhythmias (80.00) and 71.43 for Dyspnea. Cronbach's Alpha ranged between 0.916 and 0.688 for SF-36 dimensions and between 0.852 and 0.693 for AQUAREL, indicating good reliability of the instruments. It was observed that the perception of individuals facing the aspects analyzed in each dimension of SF-36 and AQUAREL is not homogeneous, being influenced by religion, gender, age, race, presence of children, work, income level, education, number of implants and the reason of the implant. The lower scores indicate which aspects need attention from the health team to contribute to the quality of life of these patients. / A qualidade de vida relacionada à saúde engloba, além dos aspectos sociais, emocionais e de bem-estar físico dos indivíduos, o impacto de alguns tratamentos empregados para controle de problemas de saúde e a habilidade do indivíduo de conduzir sua própria vida. Um dos tratamentos é o implante de marcapasso cardíaco artificial definitivo, cujos portadores relatam alterações na vida diária após o implante, que podem influenciar na qualidade de suas vidas. Trata-se de estudo descritivo exploratório, que objetivou avaliar a qualidade de vida dos portadores de marcapasso cardíaco artificial por meio de um instrumento genérico - SF-36® (Medical Outcomes Study 36-Item Short-Form Health Survey) e outro específico - AQUAREL (Assessment of Quality of Life and Related Events). Foram entrevistados 84 portadores de marcapasso cardíaco artificial definitivo após seis ou mais meses de implante. Os entrevistados tinham idade média de 59,9 anos, 58,3% eram do sexo feminino, católicos (70,2%), possuíam escolaridade fundamental incompleta (81%). Autodenominaram-se brancos (59,5%), possuíam companheiro fixo (69%) e renda mensal familiar inferior a dois salários mínimos (51,3%). O tempo de implante variou entre um e 28 anos (mediana três anos), a causa base foi a doença de Chagas (76,2%), 73,8% estavam com o 1º gerador, o tipo de estimulação predominante foi DDDR (67,9%) e pertenciam à classe funcional I (57,1%). As medianas dos escores do SF-36 foram maiores nas dimensões Aspectos Sociais (100,00) e Saúde Mental (68,00) e os menores escores foram obtidos em Aspectos Físicos (00,00) e Aspectos Emocionais (33,33). As medianas dos escores do AQUAREL foram 81,25 para Desconforto no Peito, 80,00 para Arritmias e 71,43 para Dispnéia ao Exercício. O alfa de Cronbach variou entre 0,916 e 0,688 para as dimensões do SF-36 e entre 0,852 e 0,693 para o AQUAREL, indicando boa confiabilidade dos instrumentos. Observou-se que a percepção dos indivíduos frente aos aspectos analisados em cada dimensão do SF-36 e AQUAREL não é homogênea, sendo influenciada pela religião, sexo, faixa etária, raça, presença ou não de filhos, trabalho, faixa de renda, escolaridade, número de implante e motivo do implante. Os menores escores indicam quais aspectos precisam de maior atenção por parte da equipe de saúde. Reforça-se a necessidade da atuação qualificada de uma equipe multiprofissional que acompanhe o portador de marcapasso, minimizando os fatores que possam estar interferindo na sua qualidade de vida.
14

"Estudo dos efeitos da estimulação atrial temporária na prevenção da fibrilação atrial no pós-operatório de cirurgia de revascularização do miocárdio com circulação extracorpórea" / Study the effect of temporary atrial pacing in prevention of atrial fibrillation after coronary artery bypass graft surgery

Vicente Avila Neto 12 June 2006 (has links)
Avaliamos os efeitos da estimulação atrial temporária na prevenção da fibrilação atrial no pós-operatório de revascularização do miocárdio com circulação extracorpórea e identificamos os fatores de risco para o aparecimento dessa arritmia. Estudamos 240 pacientes que ao término da cirurgia de revascularização miocárdica submeteram-se ao implante de eletrodos epicárdicos na parede lateral do átrio direito e no teto do átrio esquerdo e foram randomizados em grupo não estimulado, grupo com estímulo atrial direito e grupo com estímulo simultâneo nos átrios direito e esquerdo. Concluímos que a estimulação atrial temporária reduziu a incidência de fibrilação atrial pós-operatória e que a idade avançada e a não estimulação atrial foram fatores preditivos independentes para a ocorrência da arritmia / We studied the effects of temporary atrial pacing to prevent the atrial fibrillation after coronary artery bypass graft surgery and the risk factors to occurrence of this arrhytmia. We followed-up 240 patients after coronary artery bypass graft surgery who suffered temporary pacing atrial implantation at the end of operation. The patients were randomized into three groups according pacing stimulation into right atrial pacing, biatrial pacing and no stimulated patients. We concluded that the temporary atrial pacing reduced the incidence of postoperative atrial fibrillation. In addition older age was also a predictive factor of occurrence of atrial fibrillation
15

Estudo clínico randomizado para avaliação da segurança e dos efeitos da estimulação ventricular esquerda unifocal em pacientes com bradiarritmias / Randomized clinical trial for eficaccy, safety and performance of of isoleted left ventricular pacing in patients with bradyarrhythmias

Crevelari, Elizabeth Sartori 31 August 2018 (has links)
Introdução: Considerando-se os potenciais efeitos deletérios da estimulação do ventrículo direito (VD), a hipótese desse estudo é que a estimulação unifocal ventricular esquerda (VE) pelo seio coronário é segura e pode proporcionar melhores benefícios clínicos e ecocardiográficos aos pacientes com bloqueio atrioventricular e função ventricular esquerda preservada ou pouco alterada, necessitando apenas da correção da frequência cardíaca. Objetivos: Avaliar a segurança, a eficácia e os efeitos da estimulação ventricular esquerda, utilizando um cabo-eletrodo com fixação ativa, em comparação à estimulação ventricular direita em pacientes com indicação de marca-passo (MP) convencional e função ventricular esquerda normal a moderadamente alterada. Métodos: Trata-se de um estudo clínico, randomizado, simples-cego que incluiu pacientes adultos com indicação de MP convencional por bloqueio atrioventricular avançado e função ventricular sistólica >= 0,40. A randomização aleatória (VD vs. VE) ocorreu antes do procedimento. Os desfechos primários do estudo foram o sucesso, a segurança e a eficácia do procedimento proposto. Os desfechos secundários foram a evolução clínica e alterações ecocardiográficas. Foram empregados os testes qui-quadrado, exato de Fisher e teste t de Student para comparação dos desfechos entre os dois grupos, considerando o nível de significância de 5%. Resultados: De junho de 2012 a janeiro de 2014 foram incluídos 91 pacientes, sendo 36 no grupo VD e 55 no grupo VE. As características basais dos pacientes dos dois grupos foram similares (P = NS). O implante de MP foi realizado com sucesso e sem nenhuma intercorrência em todos os pacientes do grupo VD. No grupo VE, entretanto, dos 55 pacientes inicialmente alocados, o implante do cabo-eletrodo em veias coronárias não foi possível em 20 (36,4%) pacientes. Complicações pós-operatórias foram detectadas apenas no grupo VE. A complicação mais frequente foi a estimulação frênica, detectada em 9 (25,7%) pacientes. Durante o período de seguimento do estudo, não houve hospitalizações por insuficiência cardíaca. Reduções superiores a 10% na fração de ejeção do ventrículo esquerdo foram observadas em 23,5% dos pacientes do grupo VD e em 20,6% dos do grupo VE (P = 0,767). A análise feita pelo Doppler tecidual mostrou que 55,9% dos indivíduos do grupo VD e 43,8% dos do grupo VE apresentaram dissincronia intraventricular ventricular esquerda (P = 0,324). Pelo mesmo método, foi detectado que 91,2% e 68,8% dos pacientes dos grupos VD e VE, respectivamente, apresentavam dissincronia interventricular (P=0,022). Conclusões: A estimulação ventricular esquerda exclusiva, nas condições estudadas, mostrou taxa de sucesso, segurança e eficácia inadequadas. A despeito da melhor sincronia interventricular observada nos pacientes sob estimulação ventricular esquerda, a comparação dos desfechos secundários entre os dois grupos não mostrou diferenças significativas / Background: Considering the potential deleterious effects of right ventricular (RV) pacing, the hypothesis of this study is that isolated left ventricular (LV) pacing through the coronary sinus is safe and may provide better clinical and echocardiographic benefits to patients with bradyarrhythmias and normal ventricular function requiring only the correction of heart rate. Objective: To assess the safety, efficacy and effects of LV pacing using an active-fixation coronary sinus lead compared to RV pacing in patients eligible to conventional pacemaker (PM) implantation. Methods: Randomized, controlled and single-blinded trial in adult patients submitted to PM implantation due to bradyarrhythmias and systolic ventricular function >= 0.40. Randomization (RV vs LV) occurred before PM implantation. Procedural success, safety, and efficacy were the main endpoints. Secondary outcomes were clinical and echocardiographic changes. Chi-square, Fisher\'s exact test and Student\'s t test were used, considering a significance level of 5%. Results: From June/2012 to January/2014, 91 patients were included, 36 in the RV group and 55 in the LV group. Baseline characteristics of patients in both groups were similar. PM implantation was performed successfully and without any complications in all patients in the RV group. Of the 55 patients initially allocated to the LV group, the implant of the active-fixation coronary sinus lead was not possible in 20 (36.4%) patients. The most frequent complication was phrenic nerve stimulation, detected in 9 (25.7%) patients in the LV group. During the follow-up period, there were no hospitalizations for heart failure. Reductions of more than 10% in left ventricular ejection fraction were observed in 23.5% of patients in the RV group and in 20.6% of those in the LV group (P= 0.767). Echo-tissue doppler showed that 91.2% of subjects in the RV group and 68.8% of those in the LV group had interventricular dyssynchrony (P= 0.022). Conclusion: Isolated left ventricular pacing, under the conditions studied, showed an inadequate success rate, safety and efficacy. Despite the better interventricular synchrony observed in LV group, the comparison of secondary outcomes between the two groups did not show significant differences
16

Estudo clínico randomizado para avaliação da segurança e dos efeitos da estimulação ventricular esquerda unifocal em pacientes com bradiarritmias / Randomized clinical trial for eficaccy, safety and performance of of isoleted left ventricular pacing in patients with bradyarrhythmias

Elizabeth Sartori Crevelari 31 August 2018 (has links)
Introdução: Considerando-se os potenciais efeitos deletérios da estimulação do ventrículo direito (VD), a hipótese desse estudo é que a estimulação unifocal ventricular esquerda (VE) pelo seio coronário é segura e pode proporcionar melhores benefícios clínicos e ecocardiográficos aos pacientes com bloqueio atrioventricular e função ventricular esquerda preservada ou pouco alterada, necessitando apenas da correção da frequência cardíaca. Objetivos: Avaliar a segurança, a eficácia e os efeitos da estimulação ventricular esquerda, utilizando um cabo-eletrodo com fixação ativa, em comparação à estimulação ventricular direita em pacientes com indicação de marca-passo (MP) convencional e função ventricular esquerda normal a moderadamente alterada. Métodos: Trata-se de um estudo clínico, randomizado, simples-cego que incluiu pacientes adultos com indicação de MP convencional por bloqueio atrioventricular avançado e função ventricular sistólica >= 0,40. A randomização aleatória (VD vs. VE) ocorreu antes do procedimento. Os desfechos primários do estudo foram o sucesso, a segurança e a eficácia do procedimento proposto. Os desfechos secundários foram a evolução clínica e alterações ecocardiográficas. Foram empregados os testes qui-quadrado, exato de Fisher e teste t de Student para comparação dos desfechos entre os dois grupos, considerando o nível de significância de 5%. Resultados: De junho de 2012 a janeiro de 2014 foram incluídos 91 pacientes, sendo 36 no grupo VD e 55 no grupo VE. As características basais dos pacientes dos dois grupos foram similares (P = NS). O implante de MP foi realizado com sucesso e sem nenhuma intercorrência em todos os pacientes do grupo VD. No grupo VE, entretanto, dos 55 pacientes inicialmente alocados, o implante do cabo-eletrodo em veias coronárias não foi possível em 20 (36,4%) pacientes. Complicações pós-operatórias foram detectadas apenas no grupo VE. A complicação mais frequente foi a estimulação frênica, detectada em 9 (25,7%) pacientes. Durante o período de seguimento do estudo, não houve hospitalizações por insuficiência cardíaca. Reduções superiores a 10% na fração de ejeção do ventrículo esquerdo foram observadas em 23,5% dos pacientes do grupo VD e em 20,6% dos do grupo VE (P = 0,767). A análise feita pelo Doppler tecidual mostrou que 55,9% dos indivíduos do grupo VD e 43,8% dos do grupo VE apresentaram dissincronia intraventricular ventricular esquerda (P = 0,324). Pelo mesmo método, foi detectado que 91,2% e 68,8% dos pacientes dos grupos VD e VE, respectivamente, apresentavam dissincronia interventricular (P=0,022). Conclusões: A estimulação ventricular esquerda exclusiva, nas condições estudadas, mostrou taxa de sucesso, segurança e eficácia inadequadas. A despeito da melhor sincronia interventricular observada nos pacientes sob estimulação ventricular esquerda, a comparação dos desfechos secundários entre os dois grupos não mostrou diferenças significativas / Background: Considering the potential deleterious effects of right ventricular (RV) pacing, the hypothesis of this study is that isolated left ventricular (LV) pacing through the coronary sinus is safe and may provide better clinical and echocardiographic benefits to patients with bradyarrhythmias and normal ventricular function requiring only the correction of heart rate. Objective: To assess the safety, efficacy and effects of LV pacing using an active-fixation coronary sinus lead compared to RV pacing in patients eligible to conventional pacemaker (PM) implantation. Methods: Randomized, controlled and single-blinded trial in adult patients submitted to PM implantation due to bradyarrhythmias and systolic ventricular function >= 0.40. Randomization (RV vs LV) occurred before PM implantation. Procedural success, safety, and efficacy were the main endpoints. Secondary outcomes were clinical and echocardiographic changes. Chi-square, Fisher\'s exact test and Student\'s t test were used, considering a significance level of 5%. Results: From June/2012 to January/2014, 91 patients were included, 36 in the RV group and 55 in the LV group. Baseline characteristics of patients in both groups were similar. PM implantation was performed successfully and without any complications in all patients in the RV group. Of the 55 patients initially allocated to the LV group, the implant of the active-fixation coronary sinus lead was not possible in 20 (36.4%) patients. The most frequent complication was phrenic nerve stimulation, detected in 9 (25.7%) patients in the LV group. During the follow-up period, there were no hospitalizations for heart failure. Reductions of more than 10% in left ventricular ejection fraction were observed in 23.5% of patients in the RV group and in 20.6% of those in the LV group (P= 0.767). Echo-tissue doppler showed that 91.2% of subjects in the RV group and 68.8% of those in the LV group had interventricular dyssynchrony (P= 0.022). Conclusion: Isolated left ventricular pacing, under the conditions studied, showed an inadequate success rate, safety and efficacy. Despite the better interventricular synchrony observed in LV group, the comparison of secondary outcomes between the two groups did not show significant differences
17

Estudo prospectivo e randomizado de profilaxia antimicrobiana para procedimentos cirúrgicos em estimulação cardíaca artificial / Prospective and randomized trial of antibiotic prophylaxis for cardiac stimulation surgical procedures

Oliveira, Júlio César de 11 September 2007 (has links)
O objetivo desse estudo foi avaliar os efeitos da administração prévia de antibiótico na incidência de complicações infecciosas em procedimentos de estimulação cardíaca artificial. Os pacientes foram selecionados em um estudo duplo-cego e randomizado (1:1). Grupo I Cefazolina (1,0g dose única) versus grupo II placebo. O comitê de segurança interrompeu o estudo após a inclusão de 649 pacientes devido à diferença entre os grupos (group I 314; grupo II 335 pacientes) em favor do uso de antibiótico: 2 infectados (0,63%) versus 11 infectados no grupo placebo (3,28%); p=0,016. Marcadores identificados por análise univariada: não uso de antibiótico; procedimentos de implantes (versus trocas); hematoma pós-operatório e duração do procedimento. O não uso de antibiótico e hematoma pós-operatório foram significantes em análise multivariada / The objective of this study was to evaluate the effects of the previous venous antibiotic administration in the incidence of infectious complications in cardiac stimulation surgical procedures. Patients were selected in a double blind, randomized (1:1) trial. Group I Cefazolin (1,0g one dose) versus group II placebo. The security committee interrupted the trial after inclusion of 649 patients due to differences between groups (group I 314; group II 335 patients) in favor of the antibiotic arm: 2 infected patients (0,63%) versus 11 infected patients in the placebo arm (3,28%); p=0,016. Markers identified by univariate analysis: non-use of preventive antibiotic; implant procedures (versus replacement); post-operative haematoma and procedure duration. The non-use of antibiotic and the post-operative haematoma were independent predictors of infection in multivariate analysis
18

Estudo prospectivo e randomizado de profilaxia antimicrobiana para procedimentos cirúrgicos em estimulação cardíaca artificial / Prospective and randomized trial of antibiotic prophylaxis for cardiac stimulation surgical procedures

Júlio César de Oliveira 11 September 2007 (has links)
O objetivo desse estudo foi avaliar os efeitos da administração prévia de antibiótico na incidência de complicações infecciosas em procedimentos de estimulação cardíaca artificial. Os pacientes foram selecionados em um estudo duplo-cego e randomizado (1:1). Grupo I Cefazolina (1,0g dose única) versus grupo II placebo. O comitê de segurança interrompeu o estudo após a inclusão de 649 pacientes devido à diferença entre os grupos (group I 314; grupo II 335 pacientes) em favor do uso de antibiótico: 2 infectados (0,63%) versus 11 infectados no grupo placebo (3,28%); p=0,016. Marcadores identificados por análise univariada: não uso de antibiótico; procedimentos de implantes (versus trocas); hematoma pós-operatório e duração do procedimento. O não uso de antibiótico e hematoma pós-operatório foram significantes em análise multivariada / The objective of this study was to evaluate the effects of the previous venous antibiotic administration in the incidence of infectious complications in cardiac stimulation surgical procedures. Patients were selected in a double blind, randomized (1:1) trial. Group I Cefazolin (1,0g one dose) versus group II placebo. The security committee interrupted the trial after inclusion of 649 patients due to differences between groups (group I 314; group II 335 patients) in favor of the antibiotic arm: 2 infected patients (0,63%) versus 11 infected patients in the placebo arm (3,28%); p=0,016. Markers identified by univariate analysis: non-use of preventive antibiotic; implant procedures (versus replacement); post-operative haematoma and procedure duration. The non-use of antibiotic and the post-operative haematoma were independent predictors of infection in multivariate analysis
19

Estudo prospectivo de eventos tromboembólicos após reoperações de alta complexidade em estimulação cardíaca artificial definitiva / Prospective study of thromboembolic events after high complexity reoperation in permanent artificial cardiac pacing

Albertini, Caio Marcos de Moraes 07 December 2017 (has links)
INTRODUÇÃO: Estenose e obstruções venosas são achados frequentes após o implante de cabos-eletrodos transvenosos. Manifestações clínicas dessas lesões venosas, entretanto, são raramente reportadas. Embora exista consenso de que fenômenos tromboembólicos sejam mais comuns após reoperações que envolvam o implante de novos cabos-eletrodos ou procedimentos de extração transvenosa, ainda não existem evidências que comprovem essa observação. OBJETIVOS: Em pacientes submetidos a reoperações para corrigir disfunção em cabos-eletrodos ou para mudar o modo de estimulação, o estudo visou identificar: a) a incidência de tromboembolia pulmonar (TEP) e de trombose venosa profunda (TVP) do membro superior ipsilateral ao procedimento; b) a prevalência de lesões venosas prévias ao procedimento cirúrgico, pelo estudo venográfico, e a ocorrência de modificações desse padrão seis meses após o procedimento; e c) fatores prognósticos para a ocorrência dos eventos clínicos e das alterações venográficas. MÉTODOS: No período de abril de 2013 a julho de 2016 foram estudados 84 pacientes. A avaliação pré-operatória incluiu: ultrassonografia com doppler dos membros superiores, angiotomografia de tórax com protocolo para TEP, venografia por subtração digital e coleta de biomarcadores laboratoriais específicos do sistema de coagulação e hemostasia. Os exames diagnósticos foram repetidos no momento pós-operatório para detectar os desfechos do estudo. Todos os pacientes foram acompanhados por 12 meses. Os desfechos primários foram a ocorrência de TEP ou TVP em até 30 dias após o procedimento. Os desfechos secundários foram as alterações venográficas no sexto mês após a intervenção cirúrgica. Na análise da associação das variáveis demográficas, clínicas, operatórias e laboratoriais com os desfechos do estudo, empregou-se os testes Qui-quadrado, Exato de Fisher ou \"t\" de Student. Modelos de regressão logística multivariados foram utilizados para identificar fatores prognósticos. RESULTADOS: Entre os 84 pacientes incluídos, houve equilíbrio entre os sexos e a idade média de 59,3 ± 15,2 anos. O principal motivo para realizar o procedimento cirúrgico foi a disfunção de cabos-eletrodos (75%). A remoção de cabos-eletrodos foi efetuada em 52,4% dos casos. A taxa de eventos clínicos e subclínicos pós-operatórios foi de 35,7%, representada por TVP em 24 (28,6%) casos e TEP em seis (7,1%). Alterações no padrão venográfico seis meses após a operação foram identificadas em 34,5% dos pacientes. Os fatores prognósticos independentes para TVP foram: a presença de circulação colateral significativa na venografia pré-operatória ([odds ratio (OR) = 4,7]), (intervalo de confiança de 95% (IC 95%); 1,1 - 19,8; P = 0,037), a extração transvenosa de cabos-eletrodos (OR = 27,4; IC 95%; 5,8 - 128,8; P < 0,0001) e o aumento do fibrinogênio no pós-operatório (OR = 1,02; IC 95%; 1,01 - 1,03; P = 0,018). O histórico de tabagismo foi o único fator prognóstico relacionado com a ocorrência de TEP (OR = 14,6; IC 95%; 2,3 - 91,8; P = 0,004). Somente a extração transvenosa de cabos-eletrodos foi fator prognóstico independente (OR = 5,0; IC 95%; 1,6 - 15,4; P = 0,004) para alterações venográficas pós-operatórias. CONCLUSÃO: Reoperações envolvendo o manuseio de território venoso com cabos-eletrodos previamente implantados apresentam elevados índices de complicações tromboembólicas e de alterações venográficas. Extração transvenosa de cabos-eletrodos apresentou impacto significativo no desenvolvimento de TVP e de alterações venográficas. Esses resultados mostram a necessidade de novos estudos específicos para avaliar o papel de estratégias preventivas para esse subgrupo de pacientes / INTRODUCTION: Venous stenosis or occlusion is a frequent finding in patients with previously-implanted transvenous leads. Clinical manifestations of these venous lesions, however, are rarely reported. Although there is a consensus that thromboembolic events are more frequent after reoperation involving the implantation of new leads or lead removal, there is still no evidence to support this observation. OBJECTIVES: In patients submitted to reoperations due to lead dysfunction or device upgrade, the study aimed to determine: a) the incidence of pulmonary embolism (PE) and upper extremity deep venous thrombosis (UEDVT) ipsilateral to the cardiac device; b) the prevalence of venous lesions determined by preoperative venography, and the occurrence of modifications or progression of these lesions six months after the procedure; and c) prognostic factors for clinical and venographic outcomes. METHODS: From April/2013 to July/2016, 84 patients were studied. The preoperative evaluation included: upper extremity venous ultrasound, computed tomography pulmonary angiography, digital subtraction venography and specific laboratory tests for coagulation and hemostasis. Diagnostic exams were repeated postoperatively to detect the study outcomes. All patients were followed for 12 months. Primary outcomes were occurrence of PE or UEDVT within 30 days after the procedure. Secondary outcomes were venographic changes six months after the surgical intervention. Student\'s t test, Chi-square or Fisher\'s Exact test were used in the univariate analysis of demographic, clinical, operative and laboratory variables. Multivariate logistic regression models were used to identify prognostic factors. RESULTS: Among the 84 patients included, there was a balance between gender and the mean age was 59.3 ± 15.2 years. Lead malfunctioning (75%) was the main surgical procedure indication. Lead removal was performed in 52.4% of the cases. The rate of postoperative clinical and subclinical events was 35.7%, represented by UEDVT in 24 (28.6%) cases and PE in 6 (7.1%). Alterations in the venography findings six months after the surgery were identified in 34.5% of the patients. Independent prognostic factors for UEDVT were: the presence of significant collateral circulation in the preoperative venography ([odds ratio (OR)= 4.7; [95% confidence interval (CI): 1.1 - 19.8; P=0.037), transvenous lead extraction (OR= 27.4; 95% CI 5.8-128.8; P < 0.0001) and fibrinogen variation (OR= 1.02; 95% CI 1.01 - 1.03; P=0.018). Smoking history was the only prognostic factor related to the occurrence of PE (OR= 14.6; 95% CI 2.3 - 91.8; P=0,004). Transvenous lead extraction was the only independent prognostic factor (OR= 5.0; 95% CI 1.6 - 15.4; P=0.004) for postoperative venographic endpoints. CONCLUSION: Reoperations involving previously transvenous implanted leads present high rates of thromboembolic complications and venographic alterations. Transvenous lead extraction had a significant impact on the development of UEDVT and venographic alterations. These results show the need for further studies to evaluate the role of preventive strategies for this subgroup of patients
20

Estudo prospectivo de eventos tromboembólicos após reoperações de alta complexidade em estimulação cardíaca artificial definitiva / Prospective study of thromboembolic events after high complexity reoperation in permanent artificial cardiac pacing

Caio Marcos de Moraes Albertini 07 December 2017 (has links)
INTRODUÇÃO: Estenose e obstruções venosas são achados frequentes após o implante de cabos-eletrodos transvenosos. Manifestações clínicas dessas lesões venosas, entretanto, são raramente reportadas. Embora exista consenso de que fenômenos tromboembólicos sejam mais comuns após reoperações que envolvam o implante de novos cabos-eletrodos ou procedimentos de extração transvenosa, ainda não existem evidências que comprovem essa observação. OBJETIVOS: Em pacientes submetidos a reoperações para corrigir disfunção em cabos-eletrodos ou para mudar o modo de estimulação, o estudo visou identificar: a) a incidência de tromboembolia pulmonar (TEP) e de trombose venosa profunda (TVP) do membro superior ipsilateral ao procedimento; b) a prevalência de lesões venosas prévias ao procedimento cirúrgico, pelo estudo venográfico, e a ocorrência de modificações desse padrão seis meses após o procedimento; e c) fatores prognósticos para a ocorrência dos eventos clínicos e das alterações venográficas. MÉTODOS: No período de abril de 2013 a julho de 2016 foram estudados 84 pacientes. A avaliação pré-operatória incluiu: ultrassonografia com doppler dos membros superiores, angiotomografia de tórax com protocolo para TEP, venografia por subtração digital e coleta de biomarcadores laboratoriais específicos do sistema de coagulação e hemostasia. Os exames diagnósticos foram repetidos no momento pós-operatório para detectar os desfechos do estudo. Todos os pacientes foram acompanhados por 12 meses. Os desfechos primários foram a ocorrência de TEP ou TVP em até 30 dias após o procedimento. Os desfechos secundários foram as alterações venográficas no sexto mês após a intervenção cirúrgica. Na análise da associação das variáveis demográficas, clínicas, operatórias e laboratoriais com os desfechos do estudo, empregou-se os testes Qui-quadrado, Exato de Fisher ou \"t\" de Student. Modelos de regressão logística multivariados foram utilizados para identificar fatores prognósticos. RESULTADOS: Entre os 84 pacientes incluídos, houve equilíbrio entre os sexos e a idade média de 59,3 ± 15,2 anos. O principal motivo para realizar o procedimento cirúrgico foi a disfunção de cabos-eletrodos (75%). A remoção de cabos-eletrodos foi efetuada em 52,4% dos casos. A taxa de eventos clínicos e subclínicos pós-operatórios foi de 35,7%, representada por TVP em 24 (28,6%) casos e TEP em seis (7,1%). Alterações no padrão venográfico seis meses após a operação foram identificadas em 34,5% dos pacientes. Os fatores prognósticos independentes para TVP foram: a presença de circulação colateral significativa na venografia pré-operatória ([odds ratio (OR) = 4,7]), (intervalo de confiança de 95% (IC 95%); 1,1 - 19,8; P = 0,037), a extração transvenosa de cabos-eletrodos (OR = 27,4; IC 95%; 5,8 - 128,8; P < 0,0001) e o aumento do fibrinogênio no pós-operatório (OR = 1,02; IC 95%; 1,01 - 1,03; P = 0,018). O histórico de tabagismo foi o único fator prognóstico relacionado com a ocorrência de TEP (OR = 14,6; IC 95%; 2,3 - 91,8; P = 0,004). Somente a extração transvenosa de cabos-eletrodos foi fator prognóstico independente (OR = 5,0; IC 95%; 1,6 - 15,4; P = 0,004) para alterações venográficas pós-operatórias. CONCLUSÃO: Reoperações envolvendo o manuseio de território venoso com cabos-eletrodos previamente implantados apresentam elevados índices de complicações tromboembólicas e de alterações venográficas. Extração transvenosa de cabos-eletrodos apresentou impacto significativo no desenvolvimento de TVP e de alterações venográficas. Esses resultados mostram a necessidade de novos estudos específicos para avaliar o papel de estratégias preventivas para esse subgrupo de pacientes / INTRODUCTION: Venous stenosis or occlusion is a frequent finding in patients with previously-implanted transvenous leads. Clinical manifestations of these venous lesions, however, are rarely reported. Although there is a consensus that thromboembolic events are more frequent after reoperation involving the implantation of new leads or lead removal, there is still no evidence to support this observation. OBJECTIVES: In patients submitted to reoperations due to lead dysfunction or device upgrade, the study aimed to determine: a) the incidence of pulmonary embolism (PE) and upper extremity deep venous thrombosis (UEDVT) ipsilateral to the cardiac device; b) the prevalence of venous lesions determined by preoperative venography, and the occurrence of modifications or progression of these lesions six months after the procedure; and c) prognostic factors for clinical and venographic outcomes. METHODS: From April/2013 to July/2016, 84 patients were studied. The preoperative evaluation included: upper extremity venous ultrasound, computed tomography pulmonary angiography, digital subtraction venography and specific laboratory tests for coagulation and hemostasis. Diagnostic exams were repeated postoperatively to detect the study outcomes. All patients were followed for 12 months. Primary outcomes were occurrence of PE or UEDVT within 30 days after the procedure. Secondary outcomes were venographic changes six months after the surgical intervention. Student\'s t test, Chi-square or Fisher\'s Exact test were used in the univariate analysis of demographic, clinical, operative and laboratory variables. Multivariate logistic regression models were used to identify prognostic factors. RESULTS: Among the 84 patients included, there was a balance between gender and the mean age was 59.3 ± 15.2 years. Lead malfunctioning (75%) was the main surgical procedure indication. Lead removal was performed in 52.4% of the cases. The rate of postoperative clinical and subclinical events was 35.7%, represented by UEDVT in 24 (28.6%) cases and PE in 6 (7.1%). Alterations in the venography findings six months after the surgery were identified in 34.5% of the patients. Independent prognostic factors for UEDVT were: the presence of significant collateral circulation in the preoperative venography ([odds ratio (OR)= 4.7; [95% confidence interval (CI): 1.1 - 19.8; P=0.037), transvenous lead extraction (OR= 27.4; 95% CI 5.8-128.8; P < 0.0001) and fibrinogen variation (OR= 1.02; 95% CI 1.01 - 1.03; P=0.018). Smoking history was the only prognostic factor related to the occurrence of PE (OR= 14.6; 95% CI 2.3 - 91.8; P=0,004). Transvenous lead extraction was the only independent prognostic factor (OR= 5.0; 95% CI 1.6 - 15.4; P=0.004) for postoperative venographic endpoints. CONCLUSION: Reoperations involving previously transvenous implanted leads present high rates of thromboembolic complications and venographic alterations. Transvenous lead extraction had a significant impact on the development of UEDVT and venographic alterations. These results show the need for further studies to evaluate the role of preventive strategies for this subgroup of patients

Page generated in 0.4853 seconds